Post Run Checklist v092299 JHI revised 080802 GD Revised 2/27/08 GLD . CRYO . set pump to 3 psi . set EF1, EF3, EF4 & EFC coils to -75C . set EF2 coils to -100C . set EFC coils to -100C . set OH coils to -75C . set all TF coils to -125C . set EF4 coils to AUTO . Top cooling 75% manual . Bottom cooling 0% manual . put cc_ins and cc_out to manual at 0% . set HEAT to 35/35/35 unless requested for 60/60/60 . RGA: . Mass range: 1 to 50 . dwell time: 60 ms . samples/AMU: 4 . Autozero: on . one-scan interval: 120 sec (control - schedule to 120s) . turn off Ratiomatics & Auto-Restart . Shut down ECE . close ECE, VUV and any other Diag gate values . close ZBolo shutter . close GV1 . verify SV3 is open . verify SV4 is set to proper position (i.e. 160 steps) . check Autodialer is armed and not disabled . start ECDC as described by next day's run plan if required . gas line should be open to the bottle .toggle "GV CLOSE IN PULSE" to off if on