MAGNET COOLDOWN PROCEDURE: Revised 7/6/10 GLD Revised 5/21/12 GLD . stamp log book & fill in all info . Heat temps should be set to 35/35/35 . take RGA data . If ECDC is not running and has been requested before the run, begin plenum purging steps now (page 1 and 2 of ECDC procedure) while working through the steps below . check that upper cover cooling is set to 75% . check that lower cover cooling is set to 0% . toggle offset update on voltage/current screen of Cryo. If offsets dont reset correctly, reset Ross relays and 5V/5A supply (note: If ECDC is running, leave tf ross relay disabled) . check IGT and Mass 40 readings . set EF magnet cooling setpoints as follows EF1u,l to -175C EF2u,l to -167C EF3u,l to -169C EF4U manual to 25% EF4L manual to 20% EFCU&L to -180C . set the OH cooling setpoint to -167C . set LN2 pump to 5.0 psi . verify that the valves you expect to open do so . If ECDC is not running and has been requested before the run, continue ECDC procedure now (page 3 through page 8) but skip RGA setup on page 3. . except for EFCs and EF2s wait until the EF coils are within 10C of their setpoints . check IGT and Mass 40 readings . set TFU, TFV, TFL cooling setpoints to -140C . wait until the TF regulates at -140C and verify that there are no increases in the machine base pressure or mass 40 on the RGA . set TFU, TFV, TFL cooling setpoints to -165C . after regulation verify that there are no increases in the machine base pressure or mass 40 on the RGA . set TFU cooling setpoint to -178C . set TFV cooling setpoint to -180C . set TFL cooling setpoints to -180C . reset i2t system . at time of lockup set CC_OUT cooling setpoint to -178C . at time of lockup set CC_INS cooling to manual at 40% . wait about 1 minute and verify CC_INS pressure is within 0.2 psi of 1.2 psi . after first shot set LN2 pump pressure to 8 psi . OPTIONAL DEPENDING ON COOLING ISSUES DURING RUN --> increase pump speed to 10 psi --> enable "Enable Quad -162" with time on set to 480 seconds (On cryo_setpoint screen) . After ECDC is shutdown go to gas Bias screen & toggle "pulse B Main" and verify that it opens *******************************************************************************