Alcator C-Mod Run 1000418 Information

Back to runs

Miniproposals
Miniproposal:
Date Filed:
Title:
First Author:
Session Leader:Jim Irby (shots 1-25)

Operators
Session leader(s):Jim Irby
Physics operator(s):Joseph Snipes
Engineering operator(s):Frank Silva,Gary Dekow

Engineering Operator Run Comment
Plasma startup/Irby

Session Leader Plans

Physics Operators Plans

Session Leader Summaries

Physics Operator Summaries
Entered: Jul 7 2004 04:37:10:303PM
Author: To Be Determined
Run Plan for Tuesday April 18, 2000

Plasma run will begin at 9:00 and end by 17:00

Machine Conditioning is primary goal of run

SL: Irby
PO: Snipes
EO: Silva, Dekow

Engineering Setup:
------------------
ECDC Stopped at 05:10 to check out vacuum contiions and to
do cooldown.
Power system setup as on 1000407018

Fizzle detector should be on from t=0.080 to 1.7 s

Gas setup - fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid DISABLED
leave B-side upper as is Hybrid DISABLED
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bottom as is Hybrid DISABLED

The following gate valves should be enabled, assuming no vacuum problems:
VUV, but not ECE until Amanda checks out her system

-------------------------------------------------------------------------------

Last Saturday we were up-to-helium to pull out a failed shutter at
h-port. Though the turn around was pretty quick, we still have much
more water in the machine than we had on 4/07.

Objectives:

. continue machine conditioning

. try some short gas puffs during the discharge to test out
Spencer's wall conditioning proposal

. bring up RF as possible

. bring up DNB as possible

Summary: It was a good run. The machine ran very well with no delays. The
first two shots were the usual Tuesday OH test shot and a TF test shot. Shot
12 was a no-plasma test shot. Shot 14 was the only fizzle. The rest were full
length good plasmas although there were numerous injections. Rice said they
did not appear to be Moly injections though, so it is unclear what they were.
I suspect they could be boron nitride dust, but that is just a guess. Spencer
managed to get some wall conditioning test shots done. Otherwise, it was a
good cleanup run.

Shot,Duration(s),Ipmax(MA) Shot,Duration(s),Ipmax
1 0.000 0.016 2 0.000 0.005
3 1.890 0.781 4 1.870 0.773
5 1.890 0.776 6 1.890 0.773
7 1.893 0.776 8 1.799 0.776
9 1.877 0.776 10 1.898 0.776
11 1.887 0.776 12 0.000 0.003
13 1.858 0.773 14 0.000 0.044
15 1.825 0.778 16 1.822 0.778
17 1.711 0.776 18 1.704 0.778
19 1.704 0.783 20 1.700 0.786
21 1.862 0.765 22 1.641 0.763
23 1.878 0.763 24 1.685 0.778
25 1.874 0.776
Finished summary for 1000418 Total of 25 shots.
25 shots. 21 plasmas. 1 fizzles. 3 tests.

Shot 1: Copied shot 1000407007 and recalculated all controllers that use the
BP coils. Then, subtracted 3 ms off of the pre-puff to make it 25 ms
duration. Start with standard OH tuesday test shot. Test O.K.
Shot 2: TF test pulse at 50 kA. Test O.K.
Shot 3: Plasma! Good shot. A couple of injections on Prad.
Shot 4: Plasma! Good shot. Another couple of injections on Prad.
Shot 5: Repeat. Good shot. A couple of big and several smaller injections.
Shot 6: Repeat. Good shot. A couple of big and several smaller injections.
Shot 7: Increased nl04 from 5 to 6.5 x 10^19 m^-2. Good shot. Still a number
of impurity injections.
Shot 8: Increased nl04 to 8 x 10^19 m^-2 and added a gas puff at 1.0 s for 10
msec by asking to double the density for that time and then for 5 x
10^19 m^-2 afterward. Good shot. Still had many injections. Gas puff
is only seen on the D alpha signal.
Shot 9: Return to 5 x 10^19 m^-2 and then repeat the gas puff at 1 s but now
for 30 msec duration up to 1.5 x 10^20 m^-2 then down to 4 x 10^19
m^-2. Good shot. Gas puff slightly visible on the density.
Shot 10: Increase the gas puff to 50 msec duration starting at 1 sec. Now, it
is visible on the density, but there is also an injection at that
time. Otherwise, it is a good shot, though there is a big injection
between 0.4 and 0.5 sec that takes quite a bite out of the current.
Shot 11: Take out the gas puff at 1 sec as a control shot. Good shot, but
there is still a large injection early at 0.29 sec that takes a bite
out of the current.
Shot 12: No plasma shot to do a gas puff test. A 90 V gas puff was added from
1 - 1.05 sec in segment 1 and the other gas puffs were left in.
Segment 2 was turned off as was the fizzle detector and all power
supplies. Gas valve did not stay on all of the time, but CSP will
take what he got.
Shot 13: Raise nl04 to 8 x 10^-19 m^-2 straight across. Good shot. Again with
an injection/MARFE early at 0.3 sec.
Shot 14: Try to make the transition to diverted plasma more gradual in the
current rise by adjusting RCUR, CLEARIN, ZXL, and ZXU to reduce the
elongation slightly around cross-over of OH1. Fizzle!
Shot 15: Reduce Br0 offset from -0.5 mT to -1.0 mT. Good shot. Partially
cured the early injection problem. Still one big late injection.
Shot 16: Try moving the change in RCUR out by 0.05 s in the current rise to
avoid cross-over of OH1. Also moved CLEARIN similarly. A number of
injections again. Good shot.
Shot 17: Raised nl04 to 1 x 10^20 m^-2. Rice requested that Argon be turned on
to check out the HIREX system. Good shot. Disrupted at 1.7 s and
there still were a number of injections.
Shot 18: Try to improve the rampdown by keeping the plasma elongated past 1.7
s. Increase Argon puff to 50 msec for Rice. Good shot. Disrupted a
bit earlier though.
Shot 19: Repeat. Good shot. Large injection at 0.54 s.
Shot 20: Repeat with flappers opening at 1.0 s and remaining open for the rest
of the shot. Clear change in density at 1.0 sec. Good shot.
Shot 21: Inner wall limited discharge. Decreased RCUR to 0.66 m and CLEARIN
to -.05 m throughout the shot. Reduced the density to 7 x 10^19 m^-2
Reduced Ar puff to 25 ms duration. Centered ZCUR. Good shot. A
number of large injections. Disrupted at 1.85 s.
Shot 22: Added 110 V, 40 msec duration gas puff to Pulse Gas 3 for CSP at 1
sec. Good shot. Did not get full duty cycle on the gas puff. Need to
turn off the density feedback as well. Still lots of injections.
Shot 23: Turned off density feedback after 1.0 sec to get a steady gas puff at
1.0 sec. Good shot. Many small injections. Clear density rise at
the gas puff at 1.0 sec.
Shot 24: Reloaded the diverted plasma from shot 20. Got 1 x 10^20 m^-2. Good
shot though there are still a number of injections. Shot 25: Turned
off all gas except the gas in segment 1 including the Argon and the
density feedback.
Shot 25: Turned off all gas except the gas in segment 1 including the Argon
and the density feedback. Good shot. Lots of injections. Density
still reached 6 x 10^19 m^-2 with no gas after 0.1 sec.



Session Leader Comments

Physics Operator Comments
Apr 18 2000 08:32:46:543AMJoseph SnipesRun Plan for Tuesday April 18, 2000

Plasma run will begin at 9:00 and end by 17:00

Machine Conditioning is primary goal of run

SL: Irby
PO: Snipes
EO: Silva, Dekow

Engineering Setup:
------------------
ECDC Stopped at 05:10 to check out vacuum contiions and to
do cooldown.
Power system setup as on 1000407018

Fizzle detector should be on from t=0.080 to 1.7 s

Gas setup - fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid DISABLED
leave B-side upper as is Hybrid DISABLED
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bottom as is Hybrid DISABLED

The following gate valves should be enabled, assuming no vacuum problems:
VUV, but not ECE until Amanda checks out her system

-------------------------------------------------------------------------------

Last Saturday we were up-to-helium to pull out a failed shutter at
h-port. Though the turn around was pretty quick, we still have much
more water in the machine than we had on 4/07.

Objectives:

. continue machine conditioning

. try some short gas puffs during the discharge to test out
Spencer's wall conditioning proposal

. bring up RF as possible

. bring up DNB as possible


Apr 18 2000 08:56:38:590AM1000418001Joseph SnipesShot 1: Copied shot 1000407007 and recalculated all controllers that use the
BP coils. Then, subtracted 3 ms off of the pre-puff to make it 25 ms
duration. Start with standard OH tuesday test shot. Test O.K.
Apr 18 2000 09:11:02:247AM1000418002Joseph SnipesShot 2: TF test pulse at 50 kA. Test O.K.
Apr 18 2000 09:23:25:107AM1000418003Joseph SnipesShot 3: Plasma! Good shot.
Apr 18 2000 09:49:50:500AM1000418004Joseph SnipesShot 4: Plasma! Good shot. Another couple of injections on Prad.
Apr 18 2000 10:09:40:390AM1000418005Joseph SnipesShot 5: Repeat. Good shot. A couple of big and several smaller injections.
Apr 18 2000 10:32:56:093AM1000418006Joseph SnipesShot 6: Repeat. Good shot. A couple of big and several smaller injections.
Apr 18 2000 11:00:39:500AM1000418007Joseph SnipesShot 7: Increased nl04 from 5 to 6.5 x 10^19 m^-2. Good shot. Still a number
of impurity injections.
Apr 18 2000 11:26:19:280AM1000418008Joseph SnipesShot 8: Increased nl04 to 8 x 10^19 m^-2 and added a gas puff at 1.0 s for
10 msec by asking to double the density for that time and then for
5 x 10^19 m^-2 afterward. Good shot. Still had many injections.
Gas puff is only seen on the D alpha signal.
Apr 18 2000 11:50:32:890AM1000418009Joseph SnipesShot 9: Return to 5 x 10^19 m^-2 and then repeat the gas puff at 1 s but now
for 30 msec duration up to 1.5 x 10^20 m^-2 then down to 4 x 10^19
m^-2. Good shot. Gas puff slightly visible on the density.
Apr 18 2000 12:17:23:670PM1000418010Joseph SnipesShot 10: Increase the gas puff to 50 msec duration starting at 1 sec. Now, it
is visible on the density, but there is also an injection at that
time. Otherwise, it is a good shot, though there is a big injection
between 0.4 and 0.5 sec that takes quite a bite out of the current.
Apr 18 2000 12:35:35:747PM1000418011Joseph SnipesShot 11: Take out the gas puff at 1 sec as a control shot. Good shot, but
there is still a large injection early at 0.29 sec that takes a bite
out of the current.
Apr 18 2000 12:45:47:593PM1000418012Joseph SnipesShot 12: No plasma shot to do a gas puff test. A 90 V gas puff was added from
1 - 1.05 sec in segment 1 and the other gas puffs were left in.
Segment 2 was turned off as was the fizzle detector and all power
supplies. Gas valve did not stay on all of the time, but CSP will
take what he got.

Apr 18 2000 01:05:27:327PM1000418013Joseph SnipesShot 13: Raise nl04 to 8 x 10^-19 m^-2 straight across. Good shot. Again with
an injection/MARFE early at 0.3 sec.
Apr 18 2000 01:20:11:043PM1000418014Joseph SnipesShot 14: Try to make the transition to diverted plasma more gradual in the
current rise by adjusting RCUR, CLEARIN, ZXL, and ZXU to reduce the
elongation slightly around cross-over of OH1. Fizzle!
Apr 18 2000 01:41:45:297PM1000418015Joseph SnipesShot 15: Reduce Br0 offset from -0.5 mT to -1.0 mT. Good shot. Partially
cured the early injection problem. Still one big late injection.

Apr 18 2000 01:57:41:890PM1000418016Joseph SnipesShot 16: Try moving the change in RCUR out by 0.05 s in the current rise to
avoid cross-over of OH1. Also moved CLEARIN similarly. A number of
injections again. Good shot.
Apr 18 2000 02:17:12:293PM1000418017Joseph SnipesShot 17: Raised nl04 to 1 x 10^20 m^-2. Rice requested that Argon be turned on
to check out the HIREX system. Good shot. Disrupted at 1.7 s and
there still were a number of injections.
Apr 18 2000 02:54:25:420PM1000418018Joseph SnipesShot 18: Try to improve the rampdown by keeping the plasma elongated past 1.7
s. Increase Argon puff to 50 msec for Rice. Good shot. Disrupted a
bit earlier though.
Apr 18 2000 02:55:46:013PM1000418019Joseph SnipesShot 19: Repeat. Good shot. Large injection at 0.54 s.
Apr 18 2000 03:17:40:937PM1000418020Joseph SnipesShot 20: Repeat with flappers opening at 1.0 s and remaining open for the rest
of the shot. Clear change in density at 1.0 sec. Good shot.

Apr 18 2000 03:37:03:687PM1000418021Joseph SnipesShot 21: Inner wall limited discharge. Decreased RCUR to 0.66 m and CLEARIN
to -.05 m throughout the shot. Reduced the density to 7 x 10^19 m^-2
Reduced Ar puff to 25 ms duration. Centered ZCUR. Good shot.
A number of large injections. Disrupted at 1.85 s.

Apr 18 2000 04:03:34:670PM1000418022Joseph SnipesShot 22: Added 110 V, 40 msec duration gas puff to Pulse Gas 3 for CSP at 1 sec.
Good shot. Did not get full duty cycle on the gas puff. Need to
turn off the density feedback as well. Still lots of injections.
Apr 18 2000 04:16:54:310PM1000418023Joseph SnipesShot 23: Turned off density feedback after 1.0 sec to get a steady gas puff
at 1.0 sec. Good shot. Many small injections. Clear density rise at
the gas puff at 1.0 sec.
Apr 18 2000 04:40:24:827PM1000418024Joseph SnipesShot 24: Reloaded the diverted plasma from shot 20. Got 1 x 10^20 m^-2. Good
shot though there are still a number of injections.
Apr 18 2000 05:01:09:810PM1000418025Joseph SnipesShot 25: Turned off all gas except the gas in segment 1 including the Argon
and the density feedback. Good shot. Lots of injections. Density
still reached 6 x 10^19 m^-2 with no gas after 0.1 sec.

Apr 18 2000 05:01:49:513PM1000418025Joseph SnipesSummary: It was a good run. The machine ran very well with no delays. The
first two shots were the usual Tuesday OH test shot and a TF test shot. Shot
12 was a no-plasma test shot. Shot 14 was the only fizzle. The rest were full
length good plasmas although there were numerous injections. Rice said they
did not appear to be Moly injections though, so it is unclear what they were.
I suspect they could be boron nitride dust, but that is just a guess. Spencer
managed to get some wall conditioning test shots done. Otherwise, it was a
good cleanup run.

Shot,Duration(s),Ipmax(MA) Shot,Duration(s),Ipmax
1 0.000 0.016 2 0.000 0.005
3 1.890 0.781 4 1.870 0.773
5 1.890 0.776 6 1.890 0.773
7 1.893 0.776 8 1.799 0.776
9 1.877 0.776 10 1.898 0.776
11 1.887 0.776 12 0.000 0.003
13 1.858 0.773 14 0.000 0.044
15 1.825 0.778 16 1.822 0.778
17 1.711 0.776 18 1.704 0.778
19 1.704 0.783 20 1.700 0.786
21 1.862 0.765 22 1.641 0.763
23 1.878 0.763 24 1.685 0.778
25 1.874 0.776
Finished summary for 1000418 Total of 25 shots.
25 shots. 21 plasmas. 1 fizzles. 3 tests.

Engineering Operator Comments
ShotTimeTypeStatusComment
108:53:12:467AMTestOkOH1,2u,l 10KA co-ax test OK
209:07:51:983AMTestOk50KA TF test. Test OK
309:21:11:670AMPlasmaOkPlasma No Faults
409:45:28:547AMPlasmaOkno faults plasma
510:04:56:407AMPlasmaOk
610:27:35:747AMPlasmaOk
710:47:39:030AMPlasmaOk
811:21:16:840AMPlasmaOk
911:41:58:590AMPlasmaOk
1012:03:02:217PMPlasmaOk
1112:22:59:857PMPlasmaOk
1212:36:51:763PMPlasmaOk
1312:51:37:577PMPlasmaOk
1401:15:29:250PMPlasmaOk
1501:29:05:077PMPlasmaOk
1601:48:36:013PMPlasmaOk
1702:10:39:263PMPlasmaOk
1802:29:27:623PMPlasmaOk
1902:50:17:420PMPlasmaOk
2003:13:13:373PMPlasmaOk
2103:32:21:873PMPlasmaOk
2203:51:47:937PMPlasmaOk
2304:12:00:827PMPlasmaOk
2404:32:24:873PMPlasmaOk
2504:49:58:280PMPlasmaOk