Alcator C-Mod Run 1000901 Information

Back to runs

Miniproposals
Miniproposal:268
Date Filed: 4/7/2000
Title:Conditioning of D-, E-, or J-Port ICRF Antenna
First Author:Gerd Schilling
Session Leader:John Goetz (shots 1-25)

Operators
Session leader(s):John Goetz
Physics operator(s):Robert Granetz
Engineering operator(s):Gary Dekow,Ed Fitzgerald,Bill Cochran

Engineering Operator Run Comment
MP 268-ICRF Conditioning PO Granetz SL Goetz Operators Cochran,Dekow,Fit

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:24:743PM
Author: To Be Determined
Run 1000901 -- MP #268 - ICRF Conditioning

EO: Dekow, Parkin
PO: Granetz
SL: Goetz, Wukitch (in absentia)

The objective of this MiniProposal is to condition the D-, E-, and J-port
antennas and make them ready for plasma physics operation. A secondary
objective is to document the performance of the J-Port antenna after the
changes/improvements of the recent up-to-air period.

As with Run 1000830, the run started with conditioning shots. Each antenna
was fired separately into an inner-wall limited, 1MA, 5.2T plasma with
nl04 ~ 1. This was to ensure L-mode conditions so that inter-antenna
comparisons are straightforward. Also, the J-port antenna was fired first
during the discharge to see if any of the problems from 1000830 were due to
plasma conditions. The D- and E-port antennas conditioned up easily with
1.45-1.5MW being launched from each antenna after a few shots. Both antennas
performed well throughout this L-mode period with no faults during the day.

The J-port antenna conditioned better today compared to 1000830, that is the
number of faults were greatly reduced. However, there was still quite a bit
of glowing on the antenna and many impurity injections. Power ramps were
used to try and get around this condition and these were successful in getting
to higher launched powers (up to 1.2MW) but resulted in disruptions due to the
injections. During this conditioning at a plasma current of 1 MA the
disruptions started to occur at lower and lower powers. Eventualy it was
necessary to lower the power to 400kW (200kW each pair) to get the antenna
to run cleanly.

The current was changed to 0.8MA and conditioning was repeated. It is
interesting to note that the "glow" and the "hot spots" on the antenna changed
location. The glow appears to move over one strap toward K-port and the
"hot spot", equivalently, the impurity source, moved to the upper corner near
H-port (these locations are the strap nearest H-port and the lower H-port
corner at 1MA). The total achievable power was raised to ~1.2MW during this
set of conditioning shots just as at 1MA.

Today, the performance of the J-port antenna was not quite equal to that of the
D- and E-port antennas. It appears that the performance today was better than
that on 1000830. The central temperature increase, stored energy
increase, and the neutron rate are slightly lower (~15%) for the
J-port antenna compared to the other two antennas. This observation is only
true when the total power is low or during the ramps when the impurity
production is low. A definite comparison awaits a power absorption calculation
for all the antennas.

Shots 17-19 were used to determine if the relative phase of the 4 current
straps of the J-port antenna was responsible for the observed behavior. These
shots had [0,1,1,0]*!pi and [0,1,-0.5,0.5]*!pi phasing versus the [0,1,0,1]*!pi
(or nearly) phasing of the previous shots. The shots with [0,1,1,0]*!pi
phasing resulted in no heating while the shot with [0,1,-0.5,0.5]*!pi phasing
had just a little heating.

Overall summary:
D- and E-port antennas are well conditioned. The J-port antenna performance
is nearly equal to that of the D- and E-port antennas at low power or when
impurity production is low. There are still impurity generation problems when
the power is raised above ~800kW or when the integrated power causes a
"hot-spot" to form. These problems must be solved before this antenna can
be deemed conditioned.

Shot Result
---- ------
001 0.24MW from D; no faults
0.25MW from E; no faults; very noisy
0.24MW from J3; no faults
0.27MW from J4; no faults
glow doesn't appear to be on the antenna this shot

002 0.51MW from D; no faults
0.50MW from E; no faults; noise gone
0.34MW from J3; no faults
0.37MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)
an injection early in the pulse on this

003 0.75MW from D; no faults
0.75MW from E; no faults; noise gone
0.34->.43MW from J3; no faults
0.37->.47MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)

004 1.03MW from D; no faults
0.99MW from E; no faults; noise gone
0.34->.52MW from J3; one fault (DC1)
0.37->.57MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)
quite a few injections from the lower H-port corner

The performance of the J-port antenna has been going down as the power goes up.
Also the H/D ratio has been creeping up.

005 1.03MW from D; no faults
0.99MW from E; no faults; noise gone
0.34->.52MW from J3; one fault (DC1)
0.37->.57MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)
quite a few injections from the lower H-port corner

006 1.39MW from D; no faults
1.34MW from E; no faults
0.44->.72MW from J3; three faults (DC1) at high power
0.46->.78MW from J4; one fault (DC0) at high power
glow on the antenna is there this shot (lower H-port side),
many injections

007 disrupts at turnoff of J-antenna; plasma couldn't survive the
impurities
0.48->.59MW from J3; one fault (DC1) at low power
0.52->.66MW from J4; no faults
glow on the antenna is there this shot (lower H-port side),
many injections, the upper H-port corner is now lighting up

008 early disruption

009 disrupts at turnoff of J-antenna; plasma couldn't survive the
impurities
0.38->.46MW from J3; two faults (DC1) at high power
0.40->.52MW from J4; one fault (DC0) at high power
glow on the antenna is there this shot (lower H-port side),
many injections
the upper H-port corner didn't light up on this one

010 disrupts at turnoff of J-antenna; plasma couldn't survive the
impurities
0.26MW from J3; one fault (DC1) at low power
0.30MW from J4; no faults
no glow on the antenna
J3 fault -> injection -> boom

011 1.49MW from D; no faults
1.43MW from E; no faults
0.19MW from J3; no faults
0.21MW from J4; no faults
no glow on the antenna

012 1.49MW from D; no faults; this is about it for power from #1 - 2-4A of
screen current
1.43MW from E; no faults; there is a little more room on #2; <2A of
screen current
0.29MW from J3; no faults
0.32MW from J4; no faults
weak glow on the antenna, no injections

013 early disruption from J-port junk
0.38MW from J3; no faults
0.43MW from J4; no faults
glow on the antenna, then injections, then boom (lower H-port
corner)

014 0.51MW from D; no faults
0.50MW from E; no faults
0.24MW from J3; no faults
0.27MW from J4; no faults
no glow on the antenna, no injections

015 dud; no TF

016 0.51->.78MW from D; no faults
0.50->.78MW from E; no faults
0.24->.38MW from J3; no faults
0.27->.43MW from J4; no faults
glow on the antenna, one injection @ 0.7MW

Performance is somewhat comparable, although the injection muddles the
picture a bit.

017 early disruption from J-port
0.23->.35MW from J3; no faults
0.26->.37MW from J4; no faults
phase is [0,1,1,0]*!pi
tune is off a bit for both antennas
continuous stream of injections and actual cooling of the core
injections are coming from the upper K-port side of the antenna

018 .51->.71MW from D; no faults
.45->.67MW from E; no faults
0.23->.33MW from J3; no faults
0.27->.39MW from J4; no faults
phase is [0,1,1,0]*!pi
continuous stream of injections and actual cooling of the core
injections are coming from the upper half of the antenna

019 .51->.69MW from D; no faults
.50->.69MW from E; no faults
0.23->.33MW from J3; no faults
0.28->.37MW from J4; no faults
phase is [0,1,0.5,-0.5]*!pi
very slight heating with this phasing
glow from the lower H-port side

020 0.8MA plasma
.48->.76MW from D; no faults
.48->.74MW from E; no faults
0.23->.36MW from J3; no faults
0.26->.40MW from J4; no faults
phase is [0,1,0,1]*!pi
only a little glow and it seems to have changed location - more
toward the middle (toroidal) of the antenna
performance of J-port is only slightly below that of D and E
(neutrons, central Te, Wmhd)

021 0.8MA plasma, MARFE forms at end of J-port pulse
.57->.88MW from D; no faults
.62->.89MW from E; no faults
0.29->.42MW from J3; no faults
0.32->.47MW from J4; no faults
only a little glow and it seems to have changed location - more
toward the middle (toroidal) of the antenna
begins to have injections at 0.86MW total; injection triggers
the MARFE

022 .73->.98MW from D; no faults
.74->.96MW from E; no faults
0.33->.47MW from J3; one fault
0.37->.53MW from J4; no faults
only a little glow and it seems to have changed location - more
toward the middle (toroidal) of the antenna
the upper H-port side is aglow on this shot
injections throughout the pulse

J-port performance only a tick below that of D and E at the
1MW level (centralTe, neutron rate, Wmhd)

023 .89->.98MW from D; no faults
.88->.97MW from E; no faults
0.43->.49MW from J3; no faults
0.46->.54MW from J4; no faults
only a little glow and it seems to have changed location - more
toward the middle (toroidal) of the antenna
the upper H-port side is aglow on this shot, and I mean aglow
some small injections throughout the pulse

024 early disruption due to J-port stuff
0.48->.52MW from J3; no faults
0.51->.58MW from J4; no faults
only a little glow
the upper H-port side is aglow on this shot and causes the
disruption
some injections but not until 1.1MW of power

025 early disruption due to J-port stuff
0.48->.59MW from J3; no faults
0.51->.68MW from J4; no faults
gets in trouble above 1.2MW - lots of stuff comes in
no movie of this one
made it to 1.7keV central Te, 46kJ stored energy, 0.8e12

Physics Operator Summaries
Entered: Jul 7 2004 04:37:11:897PM
Author: To Be Determined
Physics operator summary for run 1000901:

MP 268 -- ICRF conditioning

Session leader: John Goetz
Physics operator: R. Granetz
Engineering operators: B. Cochran/B. Parkin

Summary: ECDC in D2 between shots keeps the H/D ratio down at 4-5%. I
recommend that it become standard operating procedure for RF
heating runs. J-port worked well up to about 1.0 MW, but above
that it disrupted the plasma. It's heating efficiency is not much
less than D and E. See the session leader's summary for more
details on the RF performance. The tokamak ran very well today,
and except for a no-TF shot, we had 100% startup reliability.

Scorecard: 24 plasmas
0 fizzles
1 dud (no TF)
0 tests
0 aborted
----------
25 total

-------------------------------------------------------------------------------

Engineering setup for Thursday, 01 September 2000:

Overnight ECDC in D2, stopping 1-2 hours prior to the run.

Run begins at 9:00 and ends at 17:00.

Power system setup as on 1000830019 (1 MA, 5.2 T, inner-wall limited)

Gas setup - fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid enabled
leave B-side upper as is Hybrid DISABLED
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bottom as is Hybrid DISABLED

The following gate valves should be enabled, assuming no vacuum problems:
ECE, VUV

DNB gate valve will be DISABLED today, at least for the beginning of the run.

-------------------------------------------------------------------------------

Run plan for Friday, 01 September 2000:

MP 268 -- ICRF Conditioning

Session leader: John Goetz
Physics operator: R. Granetz

Go back to the 1 MA inner-wall limited discharges from this past
Wednesday and continue to condition J-port.

-------------------------------------------------------------------------------

Overnight ECDC in D2 was started, but it shut off around 23:00. ECDC
was restarted around 05:45 and continued to 07:45.

Hybrid coldstart done; no errors found

Loaded shot 1000830019 (1.0 MA, 5.2 T, inner-wall limited)

-------------------------------------------------------------------------------

Shot 01 -- Plasma. Nice full-length discharge. Ip=0.96 MA, inner-wall
limited, nl_04=1.0e20 m-2. Outer gap=10-12 mm (not using limiter
Bp coils). H/D=4-5%. J-port=0.5 MW, D and E=0.25 MW. No
overlapping power.

Next shot: no PCS changes. Raise RF power.

Shot 02 -- Plasma. Good shot. The startup is very good. Outer gap=10-11 mm.
Prf_J=0.7 MW, Prf_D,E=0.5 MW. No overlap. No faulting. H/D=5%.
There was one brief flash from the J-port antenna (lower corner near
H-port).

Next shot: no PCS changes. Ramp J, increase D and E.

Shot 03 -- Plasma. Good shot. Outer gap=10-11 mm. Prf_J=0.8-0.85 MW,
Prf_D,E=0.75 MW. No overlap. No faulting. H/D=5-6%. There was one
brief flash from the J-port antenna (lower corner near H-port).

Next shot: no PCS changes. Raise RF power.

Shot 04 -- Plasma. Good shot. Outer gap=11-12 mm. Prf_J=0.8-1.0 MW,
Prf_D,E=1.0 MW. No overlap. One brief fault on J3 at 0.75 s.
A brief flash followed by some glowing on the J-port Faraday
screen. H/D=7-8%. We might want to do some between-shot ECDC in
D2 soon.

Next shot: no PCS changes. Raise RF power.

Shot 05 -- Plasma. Good shot. Outer gap=12 mm. Max RF=1.28 MW on each of
the three antennas. No overlap. One fault on J3. H/D=7-8%.

Next shot: no PCS changes. See if H/D comes down with the ECDC.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 06 -- Plasma. Good shot. J3 and J4 are faulting more. D and E look
good (1.30 and 1.38 MW respectively). H/D clearly dropped...down
to 5%.

Next shot: no PCS changes.

We are now doing ECDC in D2 between shots. 15 minutes.

Shot 07 -- Plasma. Disrupted at t=0.86 s. Bright sparks from the upper and
lower H-side corners of J-port. I think they caused the disruption.

Next shot: no PCS changes.

We are now doing ECDC in D2 between shots. 13 minutes.

Shot 08 -- Plasma. Disrupted at 0.41 s. Looks like a brick at 0.34 s.
No ECDC will be done after this shot.

Next shot: enable the DNB. Because of the high H2 gas loading from
the DNB, I will decrease the pre-fill pulse to 10 ms.

Shot 09 -- Plasma. Disrupted at t=0.85 s. Looks like the lower corner of
J-port again. Fill pressure was a touch low.

Next shot: lower J-port power; DNB on again; increase pre-fill
pulse to 12 ms.

Shot 10 -- Plasma. Disrupted at t=0.66 s. Lower H-corner of J-port again,
this time at only 0.5 MW. H/D is about 5%.

Next shot: lower RF power some more.

Shot 11 -- Plasma. Good, full-length shot. H/D=6-8%. Prf_J=0.4 MW,
Prf_D,E=1.45 MW. No bright spots on TV image of J-port antenna.
Density creeps up during shot, maybe due to NINJA helium puffing.

Next shot: start pushing up J-port power again.

Shot 12 -- Plasma. Good shot. Prf_J=0.6 MW, Prf_D,E=1.45 MW, no overlap.
No bright spots on J-port. H/D=9-10% !

Next shot: push J-port power up some more.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 13 -- Plasma. Disrupted at t=0.80 s. Prf_J=0.8 MW. H/D=6-7%.
Bright spot on J at usual corner. DNB is working well.

Next shot: go back down to Prf_J=0.4 MW.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 14 -- Plasma. Good shot. Prf_J,D,E=0.5 MW each. No bright spots on J.
H/D signal may not have worked properly on this shot, since it's
giving a value of 0-2%. Note: Earl says the H/D is correct.

Next shot: raise J again.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 15 -- Dud. No TF, for unknown reasons.

Shot 16 -- Plasma. Good shot. Prf_J,D,E=0.77 MW each; no overlap.
H/D=5-6% (after a dud! Note that the DNB injects H2 even on a dud.)

Next shot: change J-port phasing.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 17 -- Plasma. Disrupted at 0.86 s. Lots of bright spots from the Faraday
screen on J-port, but not from the corners. H/D=5%.
Peak Prf_J=0.8 MW.

Next shot: change J-port phasing.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 18 -- Plasma. Good shot, but there were still some bright spots on the
J-port antenna. H/D=4-5%. Prf_J,D,E=0.7 MW; no overlap.

Next shot: change J-port phasing again. There will be no DNB on
the next shot, so I've increase the pre-fill pulse to 20 ms (from
12 ms) to compensate.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 19 -- Plasma. Good shot. Only one bright spot on J-port. Neither the
DNB nor the NINJA were on on this shot. Density remained very
constant. Prf_J,D,E=0.7 MW; no overlap. No H/D data.

Next shot: lower Ip to 0.8 MA (from 1.0 MA, which it's been at all
day until now.) Also switch RF phasing back to normal.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 20 -- Plasma. Good shot. 0.8 MA. No bright spots on J-port.
Prf_J,D,E=0.8 MW each, no overlap. H/D=5%. NINJA was back on
(puffing helium, as before).

Next shot: no PCS changes. Try increasing RF power some more.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 21 -- Plasma. Good shot. Big marfe. H/D=4-5%. Bright spot on J-port
seems to initiate the marfe, which then remains for the rest of the
shot. Prf_J,D,E=0.9 MW each, no overlap.

Next shot: increase Prf a little more.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 22 -- Plasma. Good shot. Prf_J,D,E=1.0 MW, no overlap. H/D=4-5%
Lots of marfing.

Next shot: increase Prf some more.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 23 -- Plasma. Good shot, but terminates halfway down the current ramp.
Prf_J,D,E=1.0 MW, no overlap. H/D=4-5%.

Next shot: increase Prf some more.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 24 -- Plasma. Disrupted at 0.84 s. Prf_J=1.1 MW. Bright spot stayed
on for several video frames, then the plasma disrupted. H/D=4-5%

Next shot: no PCS changes.

We are now doing ECDC in D2 between shots. 10 minutes.

Shot 25 -- Plasma. Disrupted at 0.79 s. Prf_J=1.2 MW. No video on this
shot. H/D=4-5%.

End of run.

Session Leader Comments
Sep 1 2000 08:26:58:340AMJohn GoetzRun 1000901
MiniProposal #268 - ICRF conditioning

The day will be spent conditioning the J-port antenna. It has been noted that there is
a power threshold of about 800kW below which the antenna operates acceptably. Scan
of gap, current, density, and toroidal field will be done to try to get past this limit. Also,
the performance of the antenna relative to D and E antennas will be monitored.
Sep 1 2000 09:07:00:357AM1000901001John GoetzShot 1000901001:
load shot 1000830019
0.25MW from D-port @ 1.2-1.45s
0.25MW from E-port @ .9-1.15s
0.25MW from each of J-port @ 0.6-0.85s

Results:
0.24MW from D; no faults
0.25MW from E; no faults; very noisy
0.24MW from J3; no faults
0.27MW from J4; no faults
glow doesn't appear to be on the antenna this shot
Sep 1 2000 09:21:45:530AM1000901002John GoetzShot 1000901002:
0.5MW from D-port @ 1.2-1.45s
0.5MW from E-port @ .9-1.15s
0.35MW from each of J-port @ 0.6-0.85s

Results:
0.51MW from D; no faults
0.50MW from E; no faults; noise gone
0.34MW from J3; no faults
0.37MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)
an injection early in the pulse on this
Sep 1 2000 09:36:11:327AM1000901003John GoetzShot 1000901003:
0.75MW from D-port @ 1.2-1.45s
0.75MW from E-port @ .9-1.15s
0.35->0.45MW from each of J-port @ 0.6-0.85s

Results:
0.75MW from D; no faults
0.75MW from E; no faults; noise gone
0.34->.43MW from J3; no faults
0.37->.47MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)

Sep 1 2000 09:58:42:747AM1000901004John GoetzShot 1000901004:
1.0MW from D-port @ 1.2-1.45s
1.0MW from E-port @ .9-1.15s
0.35->0.55MW from each of J-port @ 0.6-0.85s

Results:
1.03MW from D; no faults
0.99MW from E; no faults; noise gone
0.34->.52MW from J3; one fault (DC1)
0.37->.57MW from J4; no faults
glow on the antenna is there this shot (lower H-port side)
quite a few injections from the lower H-port corner

The performance of the J-port antenna has been going down as the power goes up. Also the H/D ratio has been creeping up.
Sep 1 2000 10:22:54:483AM1000901005John GoetzShot 1000901005:
1.25MW from D-port @ 1.2-1.45s
1.25MW from E-port @ .9-1.15s
0.35->0.65MW from each of J-port @ 0.6-0.85s

Results:
1.29MW from D; no faults
1.23MW from E; no faults; noise gone
0.34->.61MW from J3; one fault (DC1) at high power
0.37->.57MW from J4; no faults
glow on the antenna is there this shot (lower H-port side), but no injections seen (there is one on the 2pi)

H/D is ~8% for this shot; J-port performance is lower than that of D and E (2keV vs. 2.3keV, 1.5e12 vs. 2e12)

It looks like the so-called pressure rise seen during J-port operation might be pickup. The gas pressure signal responds
instantly to the fault on J3 and there is no decay time when J shuts off.
Sep 1 2000 10:36:43:983AM1000901006John GoetzShot 1000901006:
between shot ECDC to try and get a handle on H/D
1.35MW from D-port @ 1.2-1.45s
1.35MW from E-port @ .9-1.15s
0.45->0.75MW from each of J-port @ 0.6-0.85s

Results:
1.39MW from D; no faults
1.34MW from E; no faults
0.44->.72MW from J3; three faults (DC1) at high power
0.46->.78MW from J4; one fault (DC0) at high power
glow on the antenna is there this shot (lower H-port side), many injections

H/D is ~5% for this shot; difficult to assess performance with the J-port trips
Sep 1 2000 11:01:54:233AM1000901007John GoetzShot 1000901007:
between shot ECDC to try and get a handle on H/D
1.45MW from D-port @ 1.2-1.45s
1.45MW from E-port @ .9-1.15s
0.5->0.65MW from each of J-port @ 0.6-0.85s

Results:
disrupts at turnoff of J-antenna; plasma couldn't survive the impurities
0.48->.59MW from J3; one fault (DC1) at low power
0.52->.66MW from J4; no faults
glow on the antenna is there this shot (lower H-port side), many injections
the upper H-port corner is now lighting up

H/D is <4% for this shot
Sep 1 2000 11:21:42:967AM1000901008John GoetzShot 1000901008:
between shot ECDC to try and get a handle on H/D
1.45MW from D-port @ 1.2-1.45s
1.45MW from E-port @ .9-1.15s
0.4->0.5MW from each of J-port @ 0.6-0.85s

Results:
early disruption, .42s
Sep 1 2000 11:42:31:873AM1000901009John GoetzShot 1000901009:
1.45MW from D-port @ 1.2-1.45s
1.45MW from E-port @ .9-1.15s
0.4->0.5MW from each of J-port @ 0.6-0.85s

Results:
disrupts at turnoff of J-antenna; plasma couldn't survive the impurities
0.38->.46MW from J3; two faults (DC1) at high power
0.40->.52MW from J4; one fault (DC0) at high power
glow on the antenna is there this shot (lower H-port side), many injections
the upper H-port corner didn't light up on this one

H/D is ~4% for this shot but goes up when J-port fires
Sep 1 2000 11:58:57:687AM1000901010John GoetzShot 1000901010:
1.45MW from D-port @ 1.2-1.45s
1.45MW from E-port @ .9-1.15s
0.3MW from each of J-port @ 0.6-0.85s

Results:
disrupts at turnoff of J-antenna; plasma couldn't survive the impurities
0.26MW from J3; one fault (DC1) at low power
0.30MW from J4; no faults
no glow on the antenna
J3 fault -> injection -> boom


Sep 1 2000 12:17:56:187PM1000901011John GoetzShot 1000901011:
1.45MW from D-port @ 1.2-1.45s
1.45MW from E-port @ .9-1.15s
0.2MW from each of J-port @ 0.6-0.85s

Results:
1.49MW from D; no faults
1.43MW from E; no faults
0.19MW from J3; no faults
0.21MW from J4; no faults
no glow on the antenna

Sep 1 2000 12:35:15:483PM1000901012John GoetzShot 1000901012:
1.45MW from D-port @ 1.2-1.45s
1.45MW from E-port @ .9-1.15s
0.3MW from each of J-port @ 0.6-0.85s

Results:
1.49MW from D; no faults
1.43MW from E; no faults
0.29MW from J3; no faults
0.32MW from J4; no faults
weak glow on the antenna, no injections

Sep 1 2000 12:53:21:107PM1000901013John GoetzShot 1000901013:
0.8MW from D-port @ 1.2-1.45s
0.8MW from E-port @ .9-1.15s
0.4MW from each of J-port @ 0.6-0.85s

Results:
early disruption from J-port junk
0.38MW from J3; no faults
0.43MW from J4; no faults
glow on the antenna, then injections, then boom (lower H-port corner)
Sep 1 2000 01:16:11:357PM1000901014John GoetzShot 1000901014:
0.5MW from D-port @ 1.2-1.45s
0.5MW from E-port @ .9-1.15s
0.25MW from each of J-port @ 0.6-0.85s

Results:
0.51MW from D; no faults
0.50MW from E; no faults
0.24MW from J3; no faults
0.27MW from J4; no faults
no glow on the antenna, no injections

The performance of the 3 antennas is nearly equal at this power level, with J being just a tick worse
Sep 1 2000 01:56:45:153PM1000901016John GoetzShot 1000901016:
0.5->0.8MW from D-port @ 1.2-1.45s
0.5->0.8MW from E-port @ .9-1.15s
0.25->0.4MW from each of J-port @ 0.6-0.85s

Results:
0.51->.78MW from D; no faults
0.50->.78MW from E; no faults
0.24->.38MW from J3; no faults
0.27->.43MW from J4; no faults
glow on the antenna, one injection @ 0.7MW

Performance is somewhat comparable, although the injection muddles the picture a bit.
Sep 1 2000 02:17:40:340PM1000901017John GoetzShot 1000901017:
0.5->0.8MW from D-port @ 1.2-1.45s
0.5->0.8MW from E-port @ .9-1.15s
0.25->0.4MW from each of J-port @ 0.6-0.85s
change phase to [0,1,1,0]*!pi - take the phase shifter from 195 to 15

Results:
early disruption from J-port
0.23->.35MW from J3; no faults
0.26->.37MW from J4; no faults
phase is [0,1,1,0]*!pi
tune is off a bit for both antennas
continuous stream of injections and actual cooling of the core
injections are coming from the upper K-port side of the antenna
Sep 1 2000 02:34:19:590PM1000901018John GoetzShot 1000901018:
try again to verify the phase problems
0.5->0.7MW from D-port @ 1.2-1.45s
0.5->0.7MW from E-port @ .9-1.15s
0.25->0.35MW from each of J-port @ 0.6-0.85s
change phase to [0,1,1,0]*!pi - take the phase shifter from 195 to 15

Results:
.51->.71MW from D; no faults
.45->.67MW from E; no faults
0.23->.33MW from J3; no faults
0.27->.39MW from J4; no faults
phase is [0,1,1,0]*!pi
continuous stream of injections and actual cooling of the core
injections are coming from the upper half of the antenna
Sep 1 2000 03:01:04:670PM1000901019John GoetzShot 1000901019:
0.5->0.7MW from D-port @ 1.2-1.45s
0.5->0.7MW from E-port @ .9-1.15s
0.25->0.35MW from each of J-port @ 0.6-0.85s
change phase to [0,1,-0.5,0.5]*!pi - take the phase shifter from 15 to 105

Results:
.51->.69MW from D; no faults
.50->.69MW from E; no faults
0.23->.33MW from J3; no faults
0.28->.37MW from J4; no faults
phase is [0,1,0.5,-0.5]*!pi
very slight heating with this phasing
glow from the lower H-port side
Sep 1 2000 03:20:20:543PM1000901020John GoetzShot 1000901020:
0.5->0.8MW from D-port @ 1.2-1.45s
0.5->0.8MW from E-port @ .9-1.15s
0.25->0.4MW from each of J-port @ 0.6-0.85s
change phase to [0,1,0,1]*!pi - take the phase shifter from 105 to 195
go to 0.8MA plasma

Results:
0.8MA plasma
.48->.76MW from D; no faults
.48->.74MW from E; no faults
0.23->.36MW from J3; no faults
0.26->.40MW from J4; no faults
phase is [0,1,0,1]*!pi
only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna
performance of J-port is only slightly below that of D and E (neutrons, central Te, Wmhd)
Sep 1 2000 03:40:30:890PM1000901021John GoetzShot 1000901021:
tune up for the 0.8MA plasma
0.6->0.9MW from D-port @ 1.2-1.45s
0.6->0.9MW from E-port @ .9-1.15s
0.3->0.45MW from each of J-port @ 0.6-0.85s

Results:
0.8MA plasma, MARFE forms at end of J-port pulse
.57->.88MW from D; no faults
.62->.89MW from E; no faults
0.29->.42MW from J3; no faults
0.32->.47MW from J4; no faults
only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna
begins to have injections at 0.86MW total; injection triggers the MARFE

can't assess performance of J-port because of MARFE
Sep 1 2000 04:02:11:247PM1000901022John GoetzShot 1000901022:
0.75->1.0MW from D-port @ 1.2-1.45s
0.75->1.0MW from E-port @ .9-1.15s
0.35->0.5MW from each of J-port @ 0.6-0.85s

Results:
.73->.98MW from D; no faults
.74->.96MW from E; no faults
0.33->.47MW from J3; one fault
0.37->.53MW from J4; no faults
only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna
the upper H-port side is aglow on this shot
injections throughout the pulse

J-port performance only a tick below that of D and E at the 1MW level (central Te, neutron rate, Wmhd)
Sep 1 2000 04:23:24:590PM1000901023John GoetzShot 1000901023:
0.9->1.0MW from D-port @ 1.2-1.45s
0.9->1.0MW from E-port @ .9-1.15s
0.45->0.5MW from each of J-port @ 0.6-0.85s

Results:
.89->.98MW from D; no faults
.88->.97MW from E; no faults
0.43->.49MW from J3; no faults
0.46->.54MW from J4; no faults
only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna
the upper H-port side is aglow on this shot, and I mean aglow
some small injections throughout the pulse

can't assess J-port performance because of MARFE formation
Sep 1 2000 04:42:04:623PM1000901024John GoetzShot 1000901024:
1.0->1.1MW from D-port @ 1.2-1.45s
1.0->1.1MW from E-port @ .9-1.15s
0.5->0.55MW from each of J-port @ 0.6-0.85s

Results:
early disruption due to J-port stuff
0.48->.52MW from J3; no faults
0.51->.58MW from J4; no faults
only a little glow
the upper H-port side is aglow on this shot and causes the disrution
some injections but not until 1.1MW of power

Sep 1 2000 05:08:07:530PM1000901025John GoetzShot 1000901025:
1.0->1.4MW from D-port @ 1.2-1.45s
1.0->1.4MW from E-port @ .9-1.15s
0.5->0.7MW from each of J-port @ 0.6-0.85s

Results:
early disruption due to J-port stuff
0.48->.59MW from J3; no faults
0.51->.68MW from J4; no faults
gets in trouble above 1.2MW - lots of stuff comes in
no movie of this one
made it to 1.7keV central Te, 46kJ stored energy, 0.8e12 neutron rate

Physics Operator Comments
Aug 31 2000 05:43:44:653PMRobert GranetzEngineering setup for Thursday, 01 September 2000:

Overnight ECDC in D2, stopping 1-2 hours prior to the run.

Run begins at 9:00 and ends at 17:00.

Power system setup as on 1000830019 (1 MA, 5.2 T, inner-wall limited)

Gas setup - fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid enabled
leave B-side upper as is Hybrid DISABLED
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bottom as is Hybrid DISABLED

The following gate valves should be enabled, assuming no vacuum problems:
ECE, VUV

DNB gate valve will be DISABLED today, at least for the beginning of the run.
Aug 31 2000 05:44:01:937PMRobert GranetzRun plan for Friday, 01 September 2000:

MP 268 -- ICRF Conditioning

Session leader: John Goetz
Physics operator: R. Granetz

Go back to the 1 MA inner-wall limited discharges from this past
Wednesday and continue to condition J-port.
Sep 1 2000 08:27:05:560AMRobert Granetz Overnight ECDC in D2 was started, but it shut off around 23:00. ECDC
was restarted around 05:45 and continued to 07:45.

Hybrid coldstart done; no errors found

Loaded shot 1000830019 (1.0 MA, 5.2 T, inner-wall limited)
Sep 1 2000 09:24:40:640AM1000901001Robert GranetzShot 01 -- Plasma. Nice full-length discharge. Ip=0.96 MA, inner-wall
limited, nl_04=1.0e20 m-2. Outer gap=10-12 mm (not using limiter
Bp coils). H/D=4-5%. J-port=0.5 MW, D and E=0.25 MW. No
overlapping power.

Next shot: no PCS changes. Raise RF power.
Sep 1 2000 09:28:37:840AM1000901003Robert GranetzShot 02 -- Plasma. Good shot. The startup is very good. Outer gap=10-11 mm.
Prf_J=0.7 MW, Prf_D,E=0.5 MW. No overlap. No faulting. H/D=5%.
There was one brief flash from the J-port antenna (lower corner near
H-port).

Next shot: no PCS changes. Ramp J, increase D and E.
Sep 1 2000 09:41:26:217AM1000901003Robert GranetzShot 03 -- Plasma. Good shot. Outer gap=10-11 mm. Prf_J=0.8-0.85 MW,
Prf_D,E=0.75 MW. No overlap. No faulting. H/D=5-6%. There was one
brief flash from the J-port antenna (lower corner near H-port).

Next shot: no PCS changes. Raise RF power.
Sep 1 2000 09:59:43:560AM1000901004Robert GranetzShot 04 -- Plasma. Good shot. Outer gap=11-12 mm. Prf_J=0.8-1.0 MW,
Prf_D,E=1.0 MW. No overlap. One brief fault on J3 at 0.75 s.
A brief flash followed by some glowing on the J-port Faraday
screen. H/D=7-8%. We might want to do some between-shot ECDC in
D2 soon.

Next shot: no PCS changes. Raise RF power.
Sep 1 2000 10:18:44:340AM1000901005Robert GranetzShot 05 -- Plasma. Good shot. Outer gap=12 mm. Max RF=1.28 MW on each of
the three antennas. No overlap. One fault on J3. H/D=7-8%.

Next shot: no PCS changes. See if H/D comes down with the ECDC.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 10:38:15:310AM1000901006Robert GranetzShot 06 -- Plasma. Good shot. J3 and J4 are faulting more. D and E look
good (1.30 and 1.38 MW respectively). H/D clearly dropped...down
to 5%.

Next shot: no PCS changes.

We are now doing ECDC in D2 between shots. 15 minutes.
Sep 1 2000 11:30:18:217AM1000901007Robert GranetzShot 07 -- Plasma. Disrupted at t=0.86 s. Bright sparks from the upper and
lower H-side corners of J-port. I think they caused the disruption.

Next shot: no PCS changes.

We are now doing ECDC in D2 between shots. 13 minutes.
Sep 1 2000 11:29:59:937AM1000901008Robert GranetzShot 08 -- Plasma. Disrupted at 0.41 s. Looks like a brick at 0.34 s.
No ECDC will be done after this shot.

Next shot: enable the DNB. Because of the high H2 gas loading from
the DNB, I will decrease the pre-fill pulse to 10 ms.
Sep 1 2000 11:44:03:763AM1000901009Robert GranetzShot 09 -- Plasma. Disrupted at t=0.85 s. Looks like the lower corner of
J-port again. Fill pressure was a touch low.

Next shot: lower J-port power; DNB on again; increase pre-fill
pulse to 12 ms.
Sep 1 2000 12:02:42:107PM1000901010Robert GranetzShot 10 -- Plasma. Disrupted at t=0.66 s. Lower H-corner of J-port again,
this time at only 0.5 MW. H/D is about 5%.

Next shot: lower RF power some more.
Sep 1 2000 12:22:40:217PM1000901011Robert GranetzShot 11 -- Plasma. Good, full-length shot. H/D=6-8%. Prf_J=0.4 MW,
Prf_D,E=1.45 MW. No bright spots on TV image of J-port antenna.
Density creeps up during shot, maybe due to NINJA helium puffing.

Next shot: start pushing up J-port power again.
Sep 1 2000 12:40:02:327PM1000901012Robert GranetzShot 12 -- Plasma. Good shot. Prf_J=0.6 MW, Prf_D,E=1.45 MW, no overlap.
No bright spots on J-port. H/D=9-10% !

Next shot: push J-port power up some more.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 12:57:27:747PM1000901013Robert GranetzShot 13 -- Plasma. Disrupted at t=0.80 s. Prf_J=0.8 MW. H/D=6-7%.
Bright spot on J at usual corner. DNB is working well.

Next shot: go back down to Prf_J=0.4 MW.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 01:24:52:950PM1000901014Robert GranetzShot 14 -- Plasma. Good shot. Prf_J,D,E=0.5 MW each. No bright spots on J.
H/D signal may not have worked properly on this shot, since it's
giving a value of 0-2%.

Next shot: raise J again.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 01:34:53:200PM1000901015Robert GranetzShot 15 -- Dud. No TF, for unknown reasons.
Sep 1 2000 02:00:00:497PM1000901016Robert GranetzShot 16 -- Plasma. Good shot. Prf_J,D,E=0.77 MW each; no overlap.
H/D=5-6% (after a dud! Note that the DNB injects H2 even on a dud.)

Next shot: change J-port phasing.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 02:21:11:340PM1000901017Robert GranetzShot 17 -- Plasma. Disrupted at 0.86 s. Lots of bright spots from the Faraday
screen on J-port, but not from the corners. H/D=5%.
Peak Prf_J=0.8 MW.

Next shot: change J-port phasing.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 02:45:51:950PM1000901018Robert GranetzShot 18 -- Plasma. Good shot, but there were still some bright spots on the
J-port antenna. H/D=4-5%. Prf_J,D,E=0.7 MW; no overlap.

Next shot: change J-port phasing again. There will be no DNB on
the next shot, so I've increase the pre-fill pulse to 20 ms (from
12 ms) to compensate.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 03:04:21:763PM1000901019Robert GranetzShot 19 -- Plasma. Good shot. Only one bright spot on J-port. Neither the
DNB nor the NINJA were on on this shot. Density remained very
constant. Prf_J,D,E=0.7 MW; no overlap. No H/D data.

Next shot: lower Ip to 0.8 MA (from 1.0 MA, which it's been at all
day until now.) Also switch RF phasing back to normal.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 03:27:03:607PM1000901020Robert GranetzShot 20 -- Plasma. Good shot. 0.8 MA. No bright spots on J-port.
Prf_J,D,E=0.8 MW each, no overlap. H/D=5%. NINJA was back on
(puffing helium, as before).

Next shot: no PCS changes. Try increasing RF power some more.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 03:45:16:687PM1000901021Robert GranetzShot 21 -- Plasma. Good shot. Big marfe. H/D=4-5%. Bright spot on J-port
seems to initiate the marfe, which then remains for the rest of the
shot. Prf_J,D,E=0.9 MW each, no overlap.

Next shot: increase Prf a little more.
Sep 1 2000 04:08:16:577PM1000901022Robert GranetzShot 22 -- Plasma. Good shot. Prf_J,D,E=1.0 MW, no overlap. H/D=4-5%
Lots of marfing.

Next shot: increase Prf some more.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 04:25:14:733PM1000901023Robert GranetzShot 23 -- Plasma. Good shot, but terminates halfway down the current ramp.
Prf_J,D,E=1.0 MW, no overlap. H/D=4-5%.

Next shot: increase Prf some more.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 04:57:13:950PM1000901024Robert GranetzShot 24 -- Plasma. Disrupted at 0.84 s. Prf_J=1.1 MW. Bright spot stayed
on for several video frames, then the plasma disrupted. H/D=4-5%

Next shot: no PCS changes.

We are now doing ECDC in D2 between shots. 10 minutes.
Sep 1 2000 05:15:59:733PM1000901025Robert GranetzShot 25 -- Plasma. Disrupted at 0.79 s. Prf_J=1.2 MW. No video on this
shot. H/D=4-5%.

End of run.

Engineering Operator Comments
ShotTimeTypeStatusComment
108:56:56:937AMPlasmaOk
209:13:04:497AMPlasmaOk
309:28:12:263AMPlasmaOk
409:44:36:077AMPlasmaOk
510:01:44:797AMPlasmaOk
610:27:24:420AMPlasmaOk
710:53:20:390AMPlasmaOk
811:16:10:420AMPlasmaOk
911:32:32:280AMPlasmaOk
1011:47:06:780AMPlasmaOk
1112:04:35:920PMPlasmaOk
1212:26:10:873PMPlasmaOk
1312:46:21:937PMPlasmaOk
1401:06:38:450PMPlasmaOk
1501:32:12:077PMPlasmaBadNo TF Supply
1601:45:02:340PMPlasmaOk
1702:05:48:513PMPlasmaOk
1802:26:37:590PMPlasmaOk
1902:48:13:263PMPlasmaOk
2003:09:10:920PMPlasmaOk
2103:30:34:140PMPlasmaOk
2203:51:58:200PMPlasmaOk
2304:13:18:420PMPlasmaOk
2404:34:46:747PMPlasmaOk
2504:57:43:437PMPlasmaOk