| Run 1000901 -- MP #268 - ICRF Conditioning EO: Dekow, Parkin PO: Granetz SL: Goetz, Wukitch (in absentia) The objective of this MiniProposal is to condition the D-, E-, and J-port antennas and make them ready for plasma physics operation. A secondary objective is to document the performance of the J-Port antenna after the changes/improvements of the recent up-to-air period. As with Run 1000830, the run started with conditioning shots. Each antenna was fired separately into an inner-wall limited, 1MA, 5.2T plasma with nl04 ~ 1. This was to ensure L-mode conditions so that inter-antenna comparisons are straightforward. Also, the J-port antenna was fired first during the discharge to see if any of the problems from 1000830 were due to plasma conditions. The D- and E-port antennas conditioned up easily with 1.45-1.5MW being launched from each antenna after a few shots. Both antennas performed well throughout this L-mode period with no faults during the day. The J-port antenna conditioned better today compared to 1000830, that is the number of faults were greatly reduced. However, there was still quite a bit of glowing on the antenna and many impurity injections. Power ramps were used to try and get around this condition and these were successful in getting to higher launched powers (up to 1.2MW) but resulted in disruptions due to the injections. During this conditioning at a plasma current of 1 MA the disruptions started to occur at lower and lower powers. Eventualy it was necessary to lower the power to 400kW (200kW each pair) to get the antenna to run cleanly. The current was changed to 0.8MA and conditioning was repeated. It is interesting to note that the "glow" and the "hot spots" on the antenna changed location. The glow appears to move over one strap toward K-port and the "hot spot", equivalently, the impurity source, moved to the upper corner near H-port (these locations are the strap nearest H-port and the lower H-port corner at 1MA). The total achievable power was raised to ~1.2MW during this set of conditioning shots just as at 1MA. Today, the performance of the J-port antenna was not quite equal to that of the D- and E-port antennas. It appears that the performance today was better than that on 1000830. The central temperature increase, stored energy increase, and the neutron rate are slightly lower (~15%) for the J-port antenna compared to the other two antennas. This observation is only true when the total power is low or during the ramps when the impurity production is low. A definite comparison awaits a power absorption calculation for all the antennas. Shots 17-19 were used to determine if the relative phase of the 4 current straps of the J-port antenna was responsible for the observed behavior. These shots had [0,1,1,0]*!pi and [0,1,-0.5,0.5]*!pi phasing versus the [0,1,0,1]*!pi (or nearly) phasing of the previous shots. The shots with [0,1,1,0]*!pi phasing resulted in no heating while the shot with [0,1,-0.5,0.5]*!pi phasing had just a little heating. Overall summary: D- and E-port antennas are well conditioned. The J-port antenna performance is nearly equal to that of the D- and E-port antennas at low power or when impurity production is low. There are still impurity generation problems when the power is raised above ~800kW or when the integrated power causes a "hot-spot" to form. These problems must be solved before this antenna can be deemed conditioned. Shot Result ---- ------ 001 0.24MW from D; no faults 0.25MW from E; no faults; very noisy 0.24MW from J3; no faults 0.27MW from J4; no faults glow doesn't appear to be on the antenna this shot 002 0.51MW from D; no faults 0.50MW from E; no faults; noise gone 0.34MW from J3; no faults 0.37MW from J4; no faults glow on the antenna is there this shot (lower H-port side) an injection early in the pulse on this 003 0.75MW from D; no faults 0.75MW from E; no faults; noise gone 0.34->.43MW from J3; no faults 0.37->.47MW from J4; no faults glow on the antenna is there this shot (lower H-port side) 004 1.03MW from D; no faults 0.99MW from E; no faults; noise gone 0.34->.52MW from J3; one fault (DC1) 0.37->.57MW from J4; no faults glow on the antenna is there this shot (lower H-port side) quite a few injections from the lower H-port corner The performance of the J-port antenna has been going down as the power goes up. Also the H/D ratio has been creeping up. 005 1.03MW from D; no faults 0.99MW from E; no faults; noise gone 0.34->.52MW from J3; one fault (DC1) 0.37->.57MW from J4; no faults glow on the antenna is there this shot (lower H-port side) quite a few injections from the lower H-port corner 006 1.39MW from D; no faults 1.34MW from E; no faults 0.44->.72MW from J3; three faults (DC1) at high power 0.46->.78MW from J4; one fault (DC0) at high power glow on the antenna is there this shot (lower H-port side), many injections 007 disrupts at turnoff of J-antenna; plasma couldn't survive the impurities 0.48->.59MW from J3; one fault (DC1) at low power 0.52->.66MW from J4; no faults glow on the antenna is there this shot (lower H-port side), many injections, the upper H-port corner is now lighting up 008 early disruption 009 disrupts at turnoff of J-antenna; plasma couldn't survive the impurities 0.38->.46MW from J3; two faults (DC1) at high power 0.40->.52MW from J4; one fault (DC0) at high power glow on the antenna is there this shot (lower H-port side), many injections the upper H-port corner didn't light up on this one 010 disrupts at turnoff of J-antenna; plasma couldn't survive the impurities 0.26MW from J3; one fault (DC1) at low power 0.30MW from J4; no faults no glow on the antenna J3 fault -> injection -> boom 011 1.49MW from D; no faults 1.43MW from E; no faults 0.19MW from J3; no faults 0.21MW from J4; no faults no glow on the antenna 012 1.49MW from D; no faults; this is about it for power from #1 - 2-4A of screen current 1.43MW from E; no faults; there is a little more room on #2; <2A of screen current 0.29MW from J3; no faults 0.32MW from J4; no faults weak glow on the antenna, no injections 013 early disruption from J-port junk 0.38MW from J3; no faults 0.43MW from J4; no faults glow on the antenna, then injections, then boom (lower H-port corner) 014 0.51MW from D; no faults 0.50MW from E; no faults 0.24MW from J3; no faults 0.27MW from J4; no faults no glow on the antenna, no injections 015 dud; no TF 016 0.51->.78MW from D; no faults 0.50->.78MW from E; no faults 0.24->.38MW from J3; no faults 0.27->.43MW from J4; no faults glow on the antenna, one injection @ 0.7MW Performance is somewhat comparable, although the injection muddles the picture a bit. 017 early disruption from J-port 0.23->.35MW from J3; no faults 0.26->.37MW from J4; no faults phase is [0,1,1,0]*!pi tune is off a bit for both antennas continuous stream of injections and actual cooling of the core injections are coming from the upper K-port side of the antenna 018 .51->.71MW from D; no faults .45->.67MW from E; no faults 0.23->.33MW from J3; no faults 0.27->.39MW from J4; no faults phase is [0,1,1,0]*!pi continuous stream of injections and actual cooling of the core injections are coming from the upper half of the antenna 019 .51->.69MW from D; no faults .50->.69MW from E; no faults 0.23->.33MW from J3; no faults 0.28->.37MW from J4; no faults phase is [0,1,0.5,-0.5]*!pi very slight heating with this phasing glow from the lower H-port side 020 0.8MA plasma .48->.76MW from D; no faults .48->.74MW from E; no faults 0.23->.36MW from J3; no faults 0.26->.40MW from J4; no faults phase is [0,1,0,1]*!pi only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna performance of J-port is only slightly below that of D and E (neutrons, central Te, Wmhd) 021 0.8MA plasma, MARFE forms at end of J-port pulse .57->.88MW from D; no faults .62->.89MW from E; no faults 0.29->.42MW from J3; no faults 0.32->.47MW from J4; no faults only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna begins to have injections at 0.86MW total; injection triggers the MARFE 022 .73->.98MW from D; no faults .74->.96MW from E; no faults 0.33->.47MW from J3; one fault 0.37->.53MW from J4; no faults only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna the upper H-port side is aglow on this shot injections throughout the pulse J-port performance only a tick below that of D and E at the 1MW level (centralTe, neutron rate, Wmhd) 023 .89->.98MW from D; no faults .88->.97MW from E; no faults 0.43->.49MW from J3; no faults 0.46->.54MW from J4; no faults only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna the upper H-port side is aglow on this shot, and I mean aglow some small injections throughout the pulse 024 early disruption due to J-port stuff 0.48->.52MW from J3; no faults 0.51->.58MW from J4; no faults only a little glow the upper H-port side is aglow on this shot and causes the disruption some injections but not until 1.1MW of power 025 early disruption due to J-port stuff 0.48->.59MW from J3; no faults 0.51->.68MW from J4; no faults gets in trouble above 1.2MW - lots of stuff comes in no movie of this one made it to 1.7keV central Te, 46kJ stored energy, 0.8e12 |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:11:897PM |
| Author: To Be Determined |
| Physics operator summary for run 1000901: MP 268 -- ICRF conditioning Session leader: John Goetz Physics operator: R. Granetz Engineering operators: B. Cochran/B. Parkin Summary: ECDC in D2 between shots keeps the H/D ratio down at 4-5%. I recommend that it become standard operating procedure for RF heating runs. J-port worked well up to about 1.0 MW, but above that it disrupted the plasma. It's heating efficiency is not much less than D and E. See the session leader's summary for more details on the RF performance. The tokamak ran very well today, and except for a no-TF shot, we had 100% startup reliability. Scorecard: 24 plasmas 0 fizzles 1 dud (no TF) 0 tests 0 aborted ---------- 25 total ------------------------------------------------------------------------------- Engineering setup for Thursday, 01 September 2000: Overnight ECDC in D2, stopping 1-2 hours prior to the run. Run begins at 9:00 and ends at 17:00. Power system setup as on 1000830019 (1 MA, 5.2 T, inner-wall limited) Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid enabled leave B-side upper as is Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled leave J-bottom as is Hybrid DISABLED The following gate valves should be enabled, assuming no vacuum problems: ECE, VUV DNB gate valve will be DISABLED today, at least for the beginning of the run. ------------------------------------------------------------------------------- Run plan for Friday, 01 September 2000: MP 268 -- ICRF Conditioning Session leader: John Goetz Physics operator: R. Granetz Go back to the 1 MA inner-wall limited discharges from this past Wednesday and continue to condition J-port. ------------------------------------------------------------------------------- Overnight ECDC in D2 was started, but it shut off around 23:00. ECDC was restarted around 05:45 and continued to 07:45. Hybrid coldstart done; no errors found Loaded shot 1000830019 (1.0 MA, 5.2 T, inner-wall limited) ------------------------------------------------------------------------------- Shot 01 -- Plasma. Nice full-length discharge. Ip=0.96 MA, inner-wall limited, nl_04=1.0e20 m-2. Outer gap=10-12 mm (not using limiter Bp coils). H/D=4-5%. J-port=0.5 MW, D and E=0.25 MW. No overlapping power. Next shot: no PCS changes. Raise RF power. Shot 02 -- Plasma. Good shot. The startup is very good. Outer gap=10-11 mm. Prf_J=0.7 MW, Prf_D,E=0.5 MW. No overlap. No faulting. H/D=5%. There was one brief flash from the J-port antenna (lower corner near H-port). Next shot: no PCS changes. Ramp J, increase D and E. Shot 03 -- Plasma. Good shot. Outer gap=10-11 mm. Prf_J=0.8-0.85 MW, Prf_D,E=0.75 MW. No overlap. No faulting. H/D=5-6%. There was one brief flash from the J-port antenna (lower corner near H-port). Next shot: no PCS changes. Raise RF power. Shot 04 -- Plasma. Good shot. Outer gap=11-12 mm. Prf_J=0.8-1.0 MW, Prf_D,E=1.0 MW. No overlap. One brief fault on J3 at 0.75 s. A brief flash followed by some glowing on the J-port Faraday screen. H/D=7-8%. We might want to do some between-shot ECDC in D2 soon. Next shot: no PCS changes. Raise RF power. Shot 05 -- Plasma. Good shot. Outer gap=12 mm. Max RF=1.28 MW on each of the three antennas. No overlap. One fault on J3. H/D=7-8%. Next shot: no PCS changes. See if H/D comes down with the ECDC. We are now doing ECDC in D2 between shots. 10 minutes. Shot 06 -- Plasma. Good shot. J3 and J4 are faulting more. D and E look good (1.30 and 1.38 MW respectively). H/D clearly dropped...down to 5%. Next shot: no PCS changes. We are now doing ECDC in D2 between shots. 15 minutes. Shot 07 -- Plasma. Disrupted at t=0.86 s. Bright sparks from the upper and lower H-side corners of J-port. I think they caused the disruption. Next shot: no PCS changes. We are now doing ECDC in D2 between shots. 13 minutes. Shot 08 -- Plasma. Disrupted at 0.41 s. Looks like a brick at 0.34 s. No ECDC will be done after this shot. Next shot: enable the DNB. Because of the high H2 gas loading from the DNB, I will decrease the pre-fill pulse to 10 ms. Shot 09 -- Plasma. Disrupted at t=0.85 s. Looks like the lower corner of J-port again. Fill pressure was a touch low. Next shot: lower J-port power; DNB on again; increase pre-fill pulse to 12 ms. Shot 10 -- Plasma. Disrupted at t=0.66 s. Lower H-corner of J-port again, this time at only 0.5 MW. H/D is about 5%. Next shot: lower RF power some more. Shot 11 -- Plasma. Good, full-length shot. H/D=6-8%. Prf_J=0.4 MW, Prf_D,E=1.45 MW. No bright spots on TV image of J-port antenna. Density creeps up during shot, maybe due to NINJA helium puffing. Next shot: start pushing up J-port power again. Shot 12 -- Plasma. Good shot. Prf_J=0.6 MW, Prf_D,E=1.45 MW, no overlap. No bright spots on J-port. H/D=9-10% ! Next shot: push J-port power up some more. We are now doing ECDC in D2 between shots. 10 minutes. Shot 13 -- Plasma. Disrupted at t=0.80 s. Prf_J=0.8 MW. H/D=6-7%. Bright spot on J at usual corner. DNB is working well. Next shot: go back down to Prf_J=0.4 MW. We are now doing ECDC in D2 between shots. 10 minutes. Shot 14 -- Plasma. Good shot. Prf_J,D,E=0.5 MW each. No bright spots on J. H/D signal may not have worked properly on this shot, since it's giving a value of 0-2%. Note: Earl says the H/D is correct. Next shot: raise J again. We are now doing ECDC in D2 between shots. 10 minutes. Shot 15 -- Dud. No TF, for unknown reasons. Shot 16 -- Plasma. Good shot. Prf_J,D,E=0.77 MW each; no overlap. H/D=5-6% (after a dud! Note that the DNB injects H2 even on a dud.) Next shot: change J-port phasing. We are now doing ECDC in D2 between shots. 10 minutes. Shot 17 -- Plasma. Disrupted at 0.86 s. Lots of bright spots from the Faraday screen on J-port, but not from the corners. H/D=5%. Peak Prf_J=0.8 MW. Next shot: change J-port phasing. We are now doing ECDC in D2 between shots. 10 minutes. Shot 18 -- Plasma. Good shot, but there were still some bright spots on the J-port antenna. H/D=4-5%. Prf_J,D,E=0.7 MW; no overlap. Next shot: change J-port phasing again. There will be no DNB on the next shot, so I've increase the pre-fill pulse to 20 ms (from 12 ms) to compensate. We are now doing ECDC in D2 between shots. 10 minutes. Shot 19 -- Plasma. Good shot. Only one bright spot on J-port. Neither the DNB nor the NINJA were on on this shot. Density remained very constant. Prf_J,D,E=0.7 MW; no overlap. No H/D data. Next shot: lower Ip to 0.8 MA (from 1.0 MA, which it's been at all day until now.) Also switch RF phasing back to normal. We are now doing ECDC in D2 between shots. 10 minutes. Shot 20 -- Plasma. Good shot. 0.8 MA. No bright spots on J-port. Prf_J,D,E=0.8 MW each, no overlap. H/D=5%. NINJA was back on (puffing helium, as before). Next shot: no PCS changes. Try increasing RF power some more. We are now doing ECDC in D2 between shots. 10 minutes. Shot 21 -- Plasma. Good shot. Big marfe. H/D=4-5%. Bright spot on J-port seems to initiate the marfe, which then remains for the rest of the shot. Prf_J,D,E=0.9 MW each, no overlap. Next shot: increase Prf a little more. We are now doing ECDC in D2 between shots. 10 minutes. Shot 22 -- Plasma. Good shot. Prf_J,D,E=1.0 MW, no overlap. H/D=4-5% Lots of marfing. Next shot: increase Prf some more. We are now doing ECDC in D2 between shots. 10 minutes. Shot 23 -- Plasma. Good shot, but terminates halfway down the current ramp. Prf_J,D,E=1.0 MW, no overlap. H/D=4-5%. Next shot: increase Prf some more. We are now doing ECDC in D2 between shots. 10 minutes. Shot 24 -- Plasma. Disrupted at 0.84 s. Prf_J=1.1 MW. Bright spot stayed on for several video frames, then the plasma disrupted. H/D=4-5% Next shot: no PCS changes. We are now doing ECDC in D2 between shots. 10 minutes. Shot 25 -- Plasma. Disrupted at 0.79 s. Prf_J=1.2 MW. No video on this shot. H/D=4-5%. End of run. |
| Session Leader Comments | |||
| Sep 1 2000 08:26:58:340AM | John Goetz | Run 1000901 MiniProposal #268 - ICRF conditioning The day will be spent conditioning the J-port antenna. It has been noted that there is a power threshold of about 800kW below which the antenna operates acceptably. Scan of gap, current, density, and toroidal field will be done to try to get past this limit. Also, the performance of the antenna relative to D and E antennas will be monitored. | |
| Sep 1 2000 09:07:00:357AM | 1000901001 | John Goetz | Shot 1000901001: load shot 1000830019 0.25MW from D-port @ 1.2-1.45s 0.25MW from E-port @ .9-1.15s 0.25MW from each of J-port @ 0.6-0.85s Results: 0.24MW from D; no faults 0.25MW from E; no faults; very noisy 0.24MW from J3; no faults 0.27MW from J4; no faults glow doesn't appear to be on the antenna this shot |
| Sep 1 2000 09:21:45:530AM | 1000901002 | John Goetz | Shot 1000901002: 0.5MW from D-port @ 1.2-1.45s 0.5MW from E-port @ .9-1.15s 0.35MW from each of J-port @ 0.6-0.85s Results: 0.51MW from D; no faults 0.50MW from E; no faults; noise gone 0.34MW from J3; no faults 0.37MW from J4; no faults glow on the antenna is there this shot (lower H-port side) an injection early in the pulse on this |
| Sep 1 2000 09:36:11:327AM | 1000901003 | John Goetz | Shot 1000901003: 0.75MW from D-port @ 1.2-1.45s 0.75MW from E-port @ .9-1.15s 0.35->0.45MW from each of J-port @ 0.6-0.85s Results: 0.75MW from D; no faults 0.75MW from E; no faults; noise gone 0.34->.43MW from J3; no faults 0.37->.47MW from J4; no faults glow on the antenna is there this shot (lower H-port side) |
| Sep 1 2000 09:58:42:747AM | 1000901004 | John Goetz | Shot 1000901004: 1.0MW from D-port @ 1.2-1.45s 1.0MW from E-port @ .9-1.15s 0.35->0.55MW from each of J-port @ 0.6-0.85s Results: 1.03MW from D; no faults 0.99MW from E; no faults; noise gone 0.34->.52MW from J3; one fault (DC1) 0.37->.57MW from J4; no faults glow on the antenna is there this shot (lower H-port side) quite a few injections from the lower H-port corner The performance of the J-port antenna has been going down as the power goes up. Also the H/D ratio has been creeping up. |
| Sep 1 2000 10:22:54:483AM | 1000901005 | John Goetz | Shot 1000901005: 1.25MW from D-port @ 1.2-1.45s 1.25MW from E-port @ .9-1.15s 0.35->0.65MW from each of J-port @ 0.6-0.85s Results: 1.29MW from D; no faults 1.23MW from E; no faults; noise gone 0.34->.61MW from J3; one fault (DC1) at high power 0.37->.57MW from J4; no faults glow on the antenna is there this shot (lower H-port side), but no injections seen (there is one on the 2pi) H/D is ~8% for this shot; J-port performance is lower than that of D and E (2keV vs. 2.3keV, 1.5e12 vs. 2e12) It looks like the so-called pressure rise seen during J-port operation might be pickup. The gas pressure signal responds instantly to the fault on J3 and there is no decay time when J shuts off. |
| Sep 1 2000 10:36:43:983AM | 1000901006 | John Goetz | Shot 1000901006: between shot ECDC to try and get a handle on H/D 1.35MW from D-port @ 1.2-1.45s 1.35MW from E-port @ .9-1.15s 0.45->0.75MW from each of J-port @ 0.6-0.85s Results: 1.39MW from D; no faults 1.34MW from E; no faults 0.44->.72MW from J3; three faults (DC1) at high power 0.46->.78MW from J4; one fault (DC0) at high power glow on the antenna is there this shot (lower H-port side), many injections H/D is ~5% for this shot; difficult to assess performance with the J-port trips |
| Sep 1 2000 11:01:54:233AM | 1000901007 | John Goetz | Shot 1000901007: between shot ECDC to try and get a handle on H/D 1.45MW from D-port @ 1.2-1.45s 1.45MW from E-port @ .9-1.15s 0.5->0.65MW from each of J-port @ 0.6-0.85s Results: disrupts at turnoff of J-antenna; plasma couldn't survive the impurities 0.48->.59MW from J3; one fault (DC1) at low power 0.52->.66MW from J4; no faults glow on the antenna is there this shot (lower H-port side), many injections the upper H-port corner is now lighting up H/D is <4% for this shot |
| Sep 1 2000 11:21:42:967AM | 1000901008 | John Goetz | Shot 1000901008: between shot ECDC to try and get a handle on H/D 1.45MW from D-port @ 1.2-1.45s 1.45MW from E-port @ .9-1.15s 0.4->0.5MW from each of J-port @ 0.6-0.85s Results: early disruption, .42s |
| Sep 1 2000 11:42:31:873AM | 1000901009 | John Goetz | Shot 1000901009: 1.45MW from D-port @ 1.2-1.45s 1.45MW from E-port @ .9-1.15s 0.4->0.5MW from each of J-port @ 0.6-0.85s Results: disrupts at turnoff of J-antenna; plasma couldn't survive the impurities 0.38->.46MW from J3; two faults (DC1) at high power 0.40->.52MW from J4; one fault (DC0) at high power glow on the antenna is there this shot (lower H-port side), many injections the upper H-port corner didn't light up on this one H/D is ~4% for this shot but goes up when J-port fires |
| Sep 1 2000 11:58:57:687AM | 1000901010 | John Goetz | Shot 1000901010: 1.45MW from D-port @ 1.2-1.45s 1.45MW from E-port @ .9-1.15s 0.3MW from each of J-port @ 0.6-0.85s Results: disrupts at turnoff of J-antenna; plasma couldn't survive the impurities 0.26MW from J3; one fault (DC1) at low power 0.30MW from J4; no faults no glow on the antenna J3 fault -> injection -> boom |
| Sep 1 2000 12:17:56:187PM | 1000901011 | John Goetz | Shot 1000901011: 1.45MW from D-port @ 1.2-1.45s 1.45MW from E-port @ .9-1.15s 0.2MW from each of J-port @ 0.6-0.85s Results: 1.49MW from D; no faults 1.43MW from E; no faults 0.19MW from J3; no faults 0.21MW from J4; no faults no glow on the antenna |
| Sep 1 2000 12:35:15:483PM | 1000901012 | John Goetz | Shot 1000901012: 1.45MW from D-port @ 1.2-1.45s 1.45MW from E-port @ .9-1.15s 0.3MW from each of J-port @ 0.6-0.85s Results: 1.49MW from D; no faults 1.43MW from E; no faults 0.29MW from J3; no faults 0.32MW from J4; no faults weak glow on the antenna, no injections |
| Sep 1 2000 12:53:21:107PM | 1000901013 | John Goetz | Shot 1000901013: 0.8MW from D-port @ 1.2-1.45s 0.8MW from E-port @ .9-1.15s 0.4MW from each of J-port @ 0.6-0.85s Results: early disruption from J-port junk 0.38MW from J3; no faults 0.43MW from J4; no faults glow on the antenna, then injections, then boom (lower H-port corner) |
| Sep 1 2000 01:16:11:357PM | 1000901014 | John Goetz | Shot 1000901014: 0.5MW from D-port @ 1.2-1.45s 0.5MW from E-port @ .9-1.15s 0.25MW from each of J-port @ 0.6-0.85s Results: 0.51MW from D; no faults 0.50MW from E; no faults 0.24MW from J3; no faults 0.27MW from J4; no faults no glow on the antenna, no injections The performance of the 3 antennas is nearly equal at this power level, with J being just a tick worse |
| Sep 1 2000 01:56:45:153PM | 1000901016 | John Goetz | Shot 1000901016: 0.5->0.8MW from D-port @ 1.2-1.45s 0.5->0.8MW from E-port @ .9-1.15s 0.25->0.4MW from each of J-port @ 0.6-0.85s Results: 0.51->.78MW from D; no faults 0.50->.78MW from E; no faults 0.24->.38MW from J3; no faults 0.27->.43MW from J4; no faults glow on the antenna, one injection @ 0.7MW Performance is somewhat comparable, although the injection muddles the picture a bit. |
| Sep 1 2000 02:17:40:340PM | 1000901017 | John Goetz | Shot 1000901017: 0.5->0.8MW from D-port @ 1.2-1.45s 0.5->0.8MW from E-port @ .9-1.15s 0.25->0.4MW from each of J-port @ 0.6-0.85s change phase to [0,1,1,0]*!pi - take the phase shifter from 195 to 15 Results: early disruption from J-port 0.23->.35MW from J3; no faults 0.26->.37MW from J4; no faults phase is [0,1,1,0]*!pi tune is off a bit for both antennas continuous stream of injections and actual cooling of the core injections are coming from the upper K-port side of the antenna |
| Sep 1 2000 02:34:19:590PM | 1000901018 | John Goetz | Shot 1000901018: try again to verify the phase problems 0.5->0.7MW from D-port @ 1.2-1.45s 0.5->0.7MW from E-port @ .9-1.15s 0.25->0.35MW from each of J-port @ 0.6-0.85s change phase to [0,1,1,0]*!pi - take the phase shifter from 195 to 15 Results: .51->.71MW from D; no faults .45->.67MW from E; no faults 0.23->.33MW from J3; no faults 0.27->.39MW from J4; no faults phase is [0,1,1,0]*!pi continuous stream of injections and actual cooling of the core injections are coming from the upper half of the antenna |
| Sep 1 2000 03:01:04:670PM | 1000901019 | John Goetz | Shot 1000901019: 0.5->0.7MW from D-port @ 1.2-1.45s 0.5->0.7MW from E-port @ .9-1.15s 0.25->0.35MW from each of J-port @ 0.6-0.85s change phase to [0,1,-0.5,0.5]*!pi - take the phase shifter from 15 to 105 Results: .51->.69MW from D; no faults .50->.69MW from E; no faults 0.23->.33MW from J3; no faults 0.28->.37MW from J4; no faults phase is [0,1,0.5,-0.5]*!pi very slight heating with this phasing glow from the lower H-port side |
| Sep 1 2000 03:20:20:543PM | 1000901020 | John Goetz | Shot 1000901020: 0.5->0.8MW from D-port @ 1.2-1.45s 0.5->0.8MW from E-port @ .9-1.15s 0.25->0.4MW from each of J-port @ 0.6-0.85s change phase to [0,1,0,1]*!pi - take the phase shifter from 105 to 195 go to 0.8MA plasma Results: 0.8MA plasma .48->.76MW from D; no faults .48->.74MW from E; no faults 0.23->.36MW from J3; no faults 0.26->.40MW from J4; no faults phase is [0,1,0,1]*!pi only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna performance of J-port is only slightly below that of D and E (neutrons, central Te, Wmhd) |
| Sep 1 2000 03:40:30:890PM | 1000901021 | John Goetz | Shot 1000901021: tune up for the 0.8MA plasma 0.6->0.9MW from D-port @ 1.2-1.45s 0.6->0.9MW from E-port @ .9-1.15s 0.3->0.45MW from each of J-port @ 0.6-0.85s Results: 0.8MA plasma, MARFE forms at end of J-port pulse .57->.88MW from D; no faults .62->.89MW from E; no faults 0.29->.42MW from J3; no faults 0.32->.47MW from J4; no faults only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna begins to have injections at 0.86MW total; injection triggers the MARFE can't assess performance of J-port because of MARFE |
| Sep 1 2000 04:02:11:247PM | 1000901022 | John Goetz | Shot 1000901022: 0.75->1.0MW from D-port @ 1.2-1.45s 0.75->1.0MW from E-port @ .9-1.15s 0.35->0.5MW from each of J-port @ 0.6-0.85s Results: .73->.98MW from D; no faults .74->.96MW from E; no faults 0.33->.47MW from J3; one fault 0.37->.53MW from J4; no faults only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna the upper H-port side is aglow on this shot injections throughout the pulse J-port performance only a tick below that of D and E at the 1MW level (central Te, neutron rate, Wmhd) |
| Sep 1 2000 04:23:24:590PM | 1000901023 | John Goetz | Shot 1000901023: 0.9->1.0MW from D-port @ 1.2-1.45s 0.9->1.0MW from E-port @ .9-1.15s 0.45->0.5MW from each of J-port @ 0.6-0.85s Results: .89->.98MW from D; no faults .88->.97MW from E; no faults 0.43->.49MW from J3; no faults 0.46->.54MW from J4; no faults only a little glow and it seems to have changed location - more toward the middle (toroidal) of the antenna the upper H-port side is aglow on this shot, and I mean aglow some small injections throughout the pulse can't assess J-port performance because of MARFE formation |
| Sep 1 2000 04:42:04:623PM | 1000901024 | John Goetz | Shot 1000901024: 1.0->1.1MW from D-port @ 1.2-1.45s 1.0->1.1MW from E-port @ .9-1.15s 0.5->0.55MW from each of J-port @ 0.6-0.85s Results: early disruption due to J-port stuff 0.48->.52MW from J3; no faults 0.51->.58MW from J4; no faults only a little glow the upper H-port side is aglow on this shot and causes the disrution some injections but not until 1.1MW of power |
| Sep 1 2000 05:08:07:530PM | 1000901025 | John Goetz | Shot 1000901025: 1.0->1.4MW from D-port @ 1.2-1.45s 1.0->1.4MW from E-port @ .9-1.15s 0.5->0.7MW from each of J-port @ 0.6-0.85s Results: early disruption due to J-port stuff 0.48->.59MW from J3; no faults 0.51->.68MW from J4; no faults gets in trouble above 1.2MW - lots of stuff comes in no movie of this one made it to 1.7keV central Te, 46kJ stored energy, 0.8e12 neutron rate |
| Physics Operator Comments | |||
| Aug 31 2000 05:43:44:653PM | Robert Granetz | Engineering setup for Thursday, 01 September 2000: Overnight ECDC in D2, stopping 1-2 hours prior to the run. Run begins at 9:00 and ends at 17:00. Power system setup as on 1000830019 (1 MA, 5.2 T, inner-wall limited) Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid enabled leave B-side upper as is Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled leave J-bottom as is Hybrid DISABLED The following gate valves should be enabled, assuming no vacuum problems: ECE, VUV DNB gate valve will be DISABLED today, at least for the beginning of the run. | |
| Aug 31 2000 05:44:01:937PM | Robert Granetz | Run plan for Friday, 01 September 2000: MP 268 -- ICRF Conditioning Session leader: John Goetz Physics operator: R. Granetz Go back to the 1 MA inner-wall limited discharges from this past Wednesday and continue to condition J-port. | |
| Sep 1 2000 08:27:05:560AM | Robert Granetz | Overnight ECDC in D2 was started, but it shut off around 23:00. ECDC was restarted around 05:45 and continued to 07:45. Hybrid coldstart done; no errors found Loaded shot 1000830019 (1.0 MA, 5.2 T, inner-wall limited) | |
| Sep 1 2000 09:24:40:640AM | 1000901001 | Robert Granetz | Shot 01 -- Plasma. Nice full-length discharge. Ip=0.96 MA, inner-wall limited, nl_04=1.0e20 m-2. Outer gap=10-12 mm (not using limiter Bp coils). H/D=4-5%. J-port=0.5 MW, D and E=0.25 MW. No overlapping power. Next shot: no PCS changes. Raise RF power. |
| Sep 1 2000 09:28:37:840AM | 1000901003 | Robert Granetz | Shot 02 -- Plasma. Good shot. The startup is very good. Outer gap=10-11 mm. Prf_J=0.7 MW, Prf_D,E=0.5 MW. No overlap. No faulting. H/D=5%. There was one brief flash from the J-port antenna (lower corner near H-port). Next shot: no PCS changes. Ramp J, increase D and E. |
| Sep 1 2000 09:41:26:217AM | 1000901003 | Robert Granetz | Shot 03 -- Plasma. Good shot. Outer gap=10-11 mm. Prf_J=0.8-0.85 MW, Prf_D,E=0.75 MW. No overlap. No faulting. H/D=5-6%. There was one brief flash from the J-port antenna (lower corner near H-port). Next shot: no PCS changes. Raise RF power. |
| Sep 1 2000 09:59:43:560AM | 1000901004 | Robert Granetz | Shot 04 -- Plasma. Good shot. Outer gap=11-12 mm. Prf_J=0.8-1.0 MW, Prf_D,E=1.0 MW. No overlap. One brief fault on J3 at 0.75 s. A brief flash followed by some glowing on the J-port Faraday screen. H/D=7-8%. We might want to do some between-shot ECDC in D2 soon. Next shot: no PCS changes. Raise RF power. |
| Sep 1 2000 10:18:44:340AM | 1000901005 | Robert Granetz | Shot 05 -- Plasma. Good shot. Outer gap=12 mm. Max RF=1.28 MW on each of the three antennas. No overlap. One fault on J3. H/D=7-8%. Next shot: no PCS changes. See if H/D comes down with the ECDC. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 10:38:15:310AM | 1000901006 | Robert Granetz | Shot 06 -- Plasma. Good shot. J3 and J4 are faulting more. D and E look good (1.30 and 1.38 MW respectively). H/D clearly dropped...down to 5%. Next shot: no PCS changes. We are now doing ECDC in D2 between shots. 15 minutes. |
| Sep 1 2000 11:30:18:217AM | 1000901007 | Robert Granetz | Shot 07 -- Plasma. Disrupted at t=0.86 s. Bright sparks from the upper and lower H-side corners of J-port. I think they caused the disruption. Next shot: no PCS changes. We are now doing ECDC in D2 between shots. 13 minutes. |
| Sep 1 2000 11:29:59:937AM | 1000901008 | Robert Granetz | Shot 08 -- Plasma. Disrupted at 0.41 s. Looks like a brick at 0.34 s. No ECDC will be done after this shot. Next shot: enable the DNB. Because of the high H2 gas loading from the DNB, I will decrease the pre-fill pulse to 10 ms. |
| Sep 1 2000 11:44:03:763AM | 1000901009 | Robert Granetz | Shot 09 -- Plasma. Disrupted at t=0.85 s. Looks like the lower corner of J-port again. Fill pressure was a touch low. Next shot: lower J-port power; DNB on again; increase pre-fill pulse to 12 ms. |
| Sep 1 2000 12:02:42:107PM | 1000901010 | Robert Granetz | Shot 10 -- Plasma. Disrupted at t=0.66 s. Lower H-corner of J-port again, this time at only 0.5 MW. H/D is about 5%. Next shot: lower RF power some more. |
| Sep 1 2000 12:22:40:217PM | 1000901011 | Robert Granetz | Shot 11 -- Plasma. Good, full-length shot. H/D=6-8%. Prf_J=0.4 MW, Prf_D,E=1.45 MW. No bright spots on TV image of J-port antenna. Density creeps up during shot, maybe due to NINJA helium puffing. Next shot: start pushing up J-port power again. |
| Sep 1 2000 12:40:02:327PM | 1000901012 | Robert Granetz | Shot 12 -- Plasma. Good shot. Prf_J=0.6 MW, Prf_D,E=1.45 MW, no overlap. No bright spots on J-port. H/D=9-10% ! Next shot: push J-port power up some more. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 12:57:27:747PM | 1000901013 | Robert Granetz | Shot 13 -- Plasma. Disrupted at t=0.80 s. Prf_J=0.8 MW. H/D=6-7%. Bright spot on J at usual corner. DNB is working well. Next shot: go back down to Prf_J=0.4 MW. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 01:24:52:950PM | 1000901014 | Robert Granetz | Shot 14 -- Plasma. Good shot. Prf_J,D,E=0.5 MW each. No bright spots on J. H/D signal may not have worked properly on this shot, since it's giving a value of 0-2%. Next shot: raise J again. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 01:34:53:200PM | 1000901015 | Robert Granetz | Shot 15 -- Dud. No TF, for unknown reasons. |
| Sep 1 2000 02:00:00:497PM | 1000901016 | Robert Granetz | Shot 16 -- Plasma. Good shot. Prf_J,D,E=0.77 MW each; no overlap. H/D=5-6% (after a dud! Note that the DNB injects H2 even on a dud.) Next shot: change J-port phasing. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 02:21:11:340PM | 1000901017 | Robert Granetz | Shot 17 -- Plasma. Disrupted at 0.86 s. Lots of bright spots from the Faraday screen on J-port, but not from the corners. H/D=5%. Peak Prf_J=0.8 MW. Next shot: change J-port phasing. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 02:45:51:950PM | 1000901018 | Robert Granetz | Shot 18 -- Plasma. Good shot, but there were still some bright spots on the J-port antenna. H/D=4-5%. Prf_J,D,E=0.7 MW; no overlap. Next shot: change J-port phasing again. There will be no DNB on the next shot, so I've increase the pre-fill pulse to 20 ms (from 12 ms) to compensate. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 03:04:21:763PM | 1000901019 | Robert Granetz | Shot 19 -- Plasma. Good shot. Only one bright spot on J-port. Neither the DNB nor the NINJA were on on this shot. Density remained very constant. Prf_J,D,E=0.7 MW; no overlap. No H/D data. Next shot: lower Ip to 0.8 MA (from 1.0 MA, which it's been at all day until now.) Also switch RF phasing back to normal. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 03:27:03:607PM | 1000901020 | Robert Granetz | Shot 20 -- Plasma. Good shot. 0.8 MA. No bright spots on J-port. Prf_J,D,E=0.8 MW each, no overlap. H/D=5%. NINJA was back on (puffing helium, as before). Next shot: no PCS changes. Try increasing RF power some more. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 03:45:16:687PM | 1000901021 | Robert Granetz | Shot 21 -- Plasma. Good shot. Big marfe. H/D=4-5%. Bright spot on J-port seems to initiate the marfe, which then remains for the rest of the shot. Prf_J,D,E=0.9 MW each, no overlap. Next shot: increase Prf a little more. |
| Sep 1 2000 04:08:16:577PM | 1000901022 | Robert Granetz | Shot 22 -- Plasma. Good shot. Prf_J,D,E=1.0 MW, no overlap. H/D=4-5% Lots of marfing. Next shot: increase Prf some more. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 04:25:14:733PM | 1000901023 | Robert Granetz | Shot 23 -- Plasma. Good shot, but terminates halfway down the current ramp. Prf_J,D,E=1.0 MW, no overlap. H/D=4-5%. Next shot: increase Prf some more. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 04:57:13:950PM | 1000901024 | Robert Granetz | Shot 24 -- Plasma. Disrupted at 0.84 s. Prf_J=1.1 MW. Bright spot stayed on for several video frames, then the plasma disrupted. H/D=4-5% Next shot: no PCS changes. We are now doing ECDC in D2 between shots. 10 minutes. |
| Sep 1 2000 05:15:59:733PM | 1000901025 | Robert Granetz | Shot 25 -- Plasma. Disrupted at 0.79 s. Prf_J=1.2 MW. No video on this shot. H/D=4-5%. End of run. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:56:56:937AM | Plasma | Ok | |
| 2 | 09:13:04:497AM | Plasma | Ok | |
| 3 | 09:28:12:263AM | Plasma | Ok | |
| 4 | 09:44:36:077AM | Plasma | Ok | |
| 5 | 10:01:44:797AM | Plasma | Ok | |
| 6 | 10:27:24:420AM | Plasma | Ok | |
| 7 | 10:53:20:390AM | Plasma | Ok | |
| 8 | 11:16:10:420AM | Plasma | Ok | |
| 9 | 11:32:32:280AM | Plasma | Ok | |
| 10 | 11:47:06:780AM | Plasma | Ok | |
| 11 | 12:04:35:920PM | Plasma | Ok | |
| 12 | 12:26:10:873PM | Plasma | Ok | |
| 13 | 12:46:21:937PM | Plasma | Ok | |
| 14 | 01:06:38:450PM | Plasma | Ok | |
| 15 | 01:32:12:077PM | Plasma | Bad | No TF Supply |
| 16 | 01:45:02:340PM | Plasma | Ok | |
| 17 | 02:05:48:513PM | Plasma | Ok | |
| 18 | 02:26:37:590PM | Plasma | Ok | |
| 19 | 02:48:13:263PM | Plasma | Ok | |
| 20 | 03:09:10:920PM | Plasma | Ok | |
| 21 | 03:30:34:140PM | Plasma | Ok | |
| 22 | 03:51:58:200PM | Plasma | Ok | |
| 23 | 04:13:18:420PM | Plasma | Ok | |
| 24 | 04:34:46:747PM | Plasma | Ok | |
| 25 | 04:57:43:437PM | Plasma | Ok | |