| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Amanda Hubbard |
| Physics operator(s): | Robert Granetz |
| Engineering operator(s): | Bill Parkin,Bill Cochran,Ed Fitzgerald |
| Engineering Operator Run Comment |
| etz SL Hubbard EO Fitzgerald,Cochran,Parkin |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:24:850PM |
| Author: To Be Determined |
| Run Summary for Thurs, Sept 14th, 2000 Session Leader: Amanda Hubbard Physics Operator: Bob Granetz Eng. Ops. : Bill Parkin RF Ops.: Rejean Boivin, John Goetz, Gerd Schilling et al MP 278 -- ELMs and EDA in low density H-modes Goals: Clarify the role of density on the EDA/ELM-free boundary. Investigate the ELMs previously observed in low density operation. Planned Shot sequence: 1) Start at 0.8 MA, 5.4 T, nl_04=0.5e20 m-2. RF ramped to 1.5 MW. ELM-free H-mode is anticipated at this low density. If it's EDA instead, then lower density some more. 2) Increase Prf, shot-to-shot. Look for ELMs and trends in grad-P (5 shots) 3) Slowly increase nl_04 to 1e20 m-2. Monitor EDA signatures, especially fluctuations. At each density, use 1 slow Prf ramp (to give L-H threshold and time evolution) and 1-2 shots with higher, fixed Prf to maximize grad-P and chance of triggering ELMs. Anticipate 5 densities, 2-3 shots each (15 shots) 4) If time permits, raise Ip to 1 MA (where EDA is more marginal) and repeat part of density scan to see if there is a "fixed" density limit or if there is an interdependence of q and ne. Results: This run went very well. We carried out practically all of the run plan, and obtained most of the desired results. Most of the day was spent on the planned density scan at 800 kA. It was conclusively demonstrated and well documented that there is indeed a threshold in target density for getting EDA H-modes. For a target density of nel_04 of 0.6e20 m-2 or lower, H-modes were ELM-free; at higher density they were EDA. There seems to be a progressive onset of EDA with increasing density, as evidenced by Dalpha levels, particle transport (rate of ne and radiation rise) and density fluctuations. Both diagnostics got very nice data showing the disappearance of coherent fluctuations in ELM-free H-modes and their appearance in EDA; some nice comparisons between the regimes were found for example on shots 12 (ELM-free vs EDA) and 16 (weak vs strong EDA). Hopefully a correlation of transport and mode amplitude and perhaps frequency will be possible. The RF performed very well, coupling up to 2.8 MW from D and E port on most shots, and at a variety of densities and requested waveforms. This turned out to be required, as the window for ELM-free operation was close to the low density limit for H-mode, and thresholds were about 2 MW of RF. There was thus not much room for power scans. Heating was particularly impressive at low density. Many thanks to the RF crew! When density was lowered to 3-4e19m-2, H-modes became very short and weak as found on 1000613. (eg shots 6,8,9) The ELM-free H-modes showed quite impressive performance, with core Te and Ti both up to 5 keV and pedestal Te ~900 eV. Stored energies were up to 180 kJ, and H-factors ~2.5-3. The best examples were shots 10,11,12,14,15 (800 kA) and 22,23 (1 MA). Ian reports 'phenomenally fast' edge rotation, up to 100 km/sec vs usual 40 km/sec, from analysis of edge fluctuations. Edge TS measured steep pedestal Te gradients, over 200 keV/m; one might speculate these are related. However, as is usually found in ELM-free, impurities tended to accumulate, eroding the pedestal, and the good performance was transient. EDA H-modes were steady state but did have rather lower confinement, with stored energy ~140 kJ and H-factors ~ 1.3-1.4. Since the heating is presumably similar, the cause of this increased energy transport bears investigation. EDA shots were 13,16,19 (800 kA) and 24 (1 MA). Several ELM-free shots had subsequent EDA phases, a few were hard to classify. The density threshold was not markedly different at 1 MA vs 800 kA, however the H-mode power threshold was much lower (PRF 1 MW vs 2 MW) at the same density. Several shots used slow power ramps, which should give good data for LH thresholds and studies of pedestal evolution at different densities. One goal of running ELM-free plasmas was to investigate whether they had any large ELMs, as seen on June 13. Despite the high pedestals, no evidence of ELMs or unexplained HL transitions was seen; all H-modes ended due to high radiation. Collisionality was undoubtedly low, but pressure gradients measured by edge TS apparently did not exceed our usual range; a stability analysis would be interesting. Details: ---------------------------------------------------------------------------- 1000914002 hubbard SESSION_LEADER Sep 14 2000 11:04:39:340AM nel_01 5.2e19; only 1.1 MW RF. L-mode ---------------------------------------------------------------------------- 1000914003 hubbard SESSION_LEADER Sep 14 2000 11:03:15:763AM Late H-mode 1.2 sec; took 2.1 MW power. nel-01 0.6e19m-2. Brief ELM-free period, evolving to EDA. Too late for fluctuation data. Need to raise RF power earlier. ---------------------------------------------------------------------------- 1000914004 hubbard SESSION_LEADER Sep 14 2000 11:01:02:326AM H-mode; took 2.6 MW power. nel-01 0.8-1.6e19m-2. Brief ELM-free period, evolving to EDA. Confirmed by fluctuation data. Need to reduce ne some more ---------------------------------------------------------------------------- 1000914005 hubbard SESSION_LEADER Sep 14 2000 10:31:37:576AM Dropped density to nel_1 ~6e19m-2. Got very late H-mode; it took 2.8 MW! Looks like it starts ELM-free, with periods of ELMs or EDA. Too late for fluctuation data. ---------------------------------------------------------------------------- 1000914006 hubbard SESSION_LEADER Sep 14 2000 10:49:09:983AM A series of several ELM-free H-mode was followed by one with EDA (and higher starting nel~8e19). This was confirmed by very clear fluctuation signals on the PCI and reflectometer. Radiation, however, went up fast in ELM-free, eroding the pedestals. Repeat this one. ---------------------------------------------------------------------------- 1000914007 hubbard SESSION_LEADER Sep 15 2000 2:45:37:840PM Lower RF power; L-mode ---------------------------------------------------------------------------- 1000914008 hubbard SESSION_LEADER Sep 14 2000 11:25:13:513AM . . . . . . . . . . . . . . . . . . . . Starting density is down to 3e19m-3. H-modes are getting very unclear; hardly any density response, and just a brief Te rise. Still core Te's up to 4keV! For next shots, start slowly raising density. nel 4e19 for shot 9 ---------------------------------------------------------------------------- 1000914009 hubbard SESSION_LEADER Sep 14 2000 11:55:36:733AM . . . . . . . . . . . . . . . . . . . . Starting density 4e19m-3. UP TO 5keV early in shot. RF still doing nicely, ~ 3 MW. A number of H-modes, but very short, not clear on type. Early ones have te8 to 800 eV, little ne rise. Later ones have ne rise, but modest Tedge. ----------------------------------------------------------------------------- 1000914010 hubbard SESSION_LEADER Sep 15 2000 2:46:46:873PM . . . . . . . . . . . . . . . . . . . . Starting density 5e19m-3. Got a nice, longer ELM-free H-mode early (0.61 -0.68 seconds). Impressive pedestal. Te8 to 900 eV. Te0 to 4.8 keV. There is some saturation on MIchelson and GPC Ch 2; has probably been there a few shots. Repeat, moving various fluctuation diagnostics earlier to look for any ELMs (none apparent) ----------------------------------------------------------------------------- 1000914011 hubbard SESSION_LEADER Sep 15 2000 2:48:42:013PM . . . . . . . . . . . . . . . . . . . . Repeat shot 10, increasing power earlier to move H-mode earlier. Similar ELM-free H-mode, with NO edge fluctuations on PCI or reflectometer. ----------------------------------------------------------------------------- 1000914012 hubbard SESSION_LEADER Sep 14 2000 1:03:10:810PM . . . . . . . . . . . . . . . . . . . . Starting density 6e19m-3. Series of decent H-modes. Ist ELM-free, just a hint of fluctuations late 2nd slight D-alpha rise, weak fluctn appears 3rd more EDA. All appears to confirm role of target density in fluctns as well as Dalpha. ----------------------------------------------------------------------------- 1000914013 hubbard SESSION_LEADER Sep 14 2000 3:32:02:793PM . . . . . . . . . . . . . . . . . . . . Starting density 7e19m-3. Still nice steady RF. Series of decent H-modes. All are now EDA, based on both D-alpha and PCI fluctuation, which is MUCH stronger than on shot 6. Looks like we've found our EDA threshold! Particle transport Next shot; back to target 6e19 m-3 ramping RF power, ----------------------------------------------------------------------------- 1000914014 hubbard SESSION_LEADER Sep 14 2000 3:47:32:500PM . . . . . . . . . . . . . . . . . . . . Back to starting density 6e19m-3. RF power ramped. Threshold 1.8 MW; still high. 2 H-modes. The first shows a hint of fluctuations on PCI, mainly ELM-free. 2nd EDA ----------------------------------------------------------------------------- 1000914015 hubbard SESSION_LEADER Sep 14 2000 3:48:39:436PM . . . . . . . . . . . . . . . . . . . . Back to starting density 6e19m-3. RF power reduced to 2 MW. Not very different from higher power; a weak hint of EDA fluctuations, a bit higher D-alpha. Next shot: target 8e19, power ramped. ----------------------------------------------------------------------------- 1000914016 hubbard SESSION_LEADER Sep 14 2000 3:49:40:873PM . . . . . . . . . . . . . . . . . . . . Starting density 8e19m-3. RF power ramped 1-2.8 MW, as requested, Two H-modes, both EDA but the second is much steadier. Interestingly, PCI shows fluctuations are weaker in the first, and only start after a delay. The second, steadier EDA has much stronger fluctuations; seems to be a quantitative correlation with particle transport. The bad news is energy transport is also dropping; only H~1.3 vs 2.5 early in day. ----------------------------------------------------------------------------- 1000914017 hubbard SESSION_LEADER Sep 14 2000 3:52:04:733PM . . . . . . . . . . . . . . . . . . . . Starting density 9e19m-3. RF power ramped 1-2.8 MW, as requested, One long, quite steady EDA. ----------------------------------------------------------------------------- 1000914018 hubbard SESSION_LEADER Sep 14 2000 3:52:52:186PM . . . . . . . . . . . . . . . . . . . . Starting density 1.1e19m-3. RF power lower; L-mode. ----------------------------------------------------------------------------- 1000914019 hubbard SESSION_LEADER Sep 14 2000 3:51:26:340PM . . . . . . . . . . . . . . . . . . . . Target 1.1e19. Ramped RF, steady EDA. This finished 800 kA density scan. Now go to 1 MA, low density. ----------------------------------------------------------------------------- 1000914020 hubbard SESSION_LEADER Sep 14 2000 3:50:50:903PM . . . . . . . . . . . . . . . . . . . . 1 MA. Target 6e19m-2. Ramped RF. Nice series of H-modes. 1st is ELM-free, no PCI fluctuation. 2nd is EDA, clear fluctuation. Next shot: same density, steady RF. ----------------------------------------------------------------------------- 1000914021 hubbard SESSION_LEADER Sep 14 2000 4:12:31:780PM . . . . . . . . . . . . . . . . . . . . Target still 6e19 m-2; actual a bit higher? Level 2.6 MW; some trips late. 2 H-modes, type not so clear. ELM-free or weak eda?? Lower target for next shot. ----------------------------------------------------------------------------- 1000914022 hubbard SESSION_LEADER Sep 14 2000 4:14:34:606PM . . . . . . . . . . . . . . . . . . . . Target 5e19. 2 H-modes. 1st definitely ELM-free. No fluctuations, Te8 840 eV, 180 kJ Later Weak EDA (late fluctns); Teped 413 eV, 114 kJ. Much lower confinement in EDA, all day. ----------------------------------------------------------------------------- 1000914023 hubbard SESSION_LEADER Sep 14 2000 4:34:49:670PM . . . . . . . . . . . . . . . . . . . . Target 7e19. 4 H-modes. 1st still looks fairly ELM-free; possibly weak EDA Te8 730 eV, 173 kJ Later EDA H-modes; Teped 385 eV, 132 kJ. ----------------------------------------------------------------------------- 1000914024 hubbard SESSION_LEADER Sep 14 2000 5:45:17:670PM . . . . . . . . . . . . . . . . . . . . Target 7e19. Did between shot ECDC. H-mode Looks a bit more EDAish, but still weak. RF trips early,. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:12:020PM |
| Author: To Be Determined |
| Physics operator summary for run 1000914: MP 278 -- ELMs and EDA in low density H-modes Session leader: Amanda Hubbard Physics operator: R. Granetz Engineering operators: E. Fitzgerald/W. Parkin Summary: It was a good run, we got through everything in the run plan. Both the machine and the D and E antennas worked well all day. We were able to run down to nl_04=3e19 m-2. H/D was generally 10% or higher today, but the RF seemed to do a good job of heating anyway. See Amanda's run summary for more information on the ELMfree and EDA H-modes at low density. No obvious Type-I ELMs were seen. Scorecard: 23 plasmas 2 fizzles 0 dud 0 tests 0 aborted ---------- 25 total ------------------------------------------------------------------------------- Engineering setup for Thursday, 14 September 2000: Overnight ECDC in HELIUM, stopping 1-2 hours prior to the run. Run begins at 9:00 and ends at 17:00. Power system setup as on 1000913005. Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid enabled fill B-side upper with 35 psi of He Hybrid DISABLED (Yes, HELIUM) (available for between-shot ECDC) fill C-side with 30 psi of D2 Hybrid enabled leave J-bottom as is Hybrid DISABLED The following gate valves should be enabled, assuming no vacuum problems: ECE, VUV DNB gate valve will be DISABLED for the beginning of the run; may enable later. ------------------------------------------------------------------------------- Run plan for Thursday, 14 September 2000: MP 278 -- ELMs and EDA in low density H-modes Session leader: Amanda Hubbard Physics operator: R. Granetz Goals: Clarify the role of density on the EDA/ELM-free boundary. Investigate the ELMs previously observed in low density operation. Shot sequence: 1) Start at 0.8 MA, 5.4 T, nl_04=0.5e20 m-2. RF ramped to 1.5 MW. ELM-free H-mode is anticipated at this low density. If it's EDA instead, then lower density some more. 2) Increase Prf, shot-to-shot. Look for ELMs and trends in grad-P (5 shots) 3) Slowly increase nl_04 to 1e20 m-2. Monitor EDA signatures, especially fluctuations. At each density, use 1 slow Prf ramp (to give L-H threshold and time evolution) and 1-2 shots with higher, fixed Prf to maximize grad-P and chance of triggering ELMs. Anticipate 5 densities, 2-3 shots each (15 shots) 4) If time permits, raise Ip to 1 MA (where EDA is more marginal) and repeat part of density scan to see if there is a "fixed" density limit or if there is an interdependence of q and ne. ------------------------------------------------------------------------------- Overnight ECDC in He Hybrid coldstart done; no errors found Loaded shot 1000913005 (segment 1 from 1000913016) and reduced Ip to 0.8 MA and nl_04 to 0.5e20 m-2. Remove waggle in Btor. Add 2 ms to pre-fill puff. ------------------------------------------------------------------------------- Shot 01 -- Fizzle. Pre-fill pressure was too low (due to He ECDC). Main video cameras have no synch signal. Jim Terry needs cell access to fix. Next shot: add 5 ms to pre-fill puff. Shot 02 -- Plasma. Good shot. Ip=0.8 MA, Bt=5.4 T, nl_04=0.5e20 m-2, as requested. RF ramped, but started faulting around 1 MW. There was some heating, but no H-mode. Next shot: lower Br0 by 0.5 mT and increase IC_EF4 by +10 amps. Try for a little higher RF power. Shot 03 -- Plasma. Good shot. nl_04=5.5-6e20 m-2. Got an H-mode which briefly started as ELMfree before changing to EDA. Prf ramped up to 2.0 MW and then leveled off. Pthreshold=2 MW. Strike point is almost on the floor. Next shot: raise ZXL by 5 mm. Ramp RF to 2 MW earlier in the shot. Shot 04 -- Plasma. Good shot. nl_04=0.7e20 m-2. The increase in the density is coming from the RF. EDA H-mode (starting briefly as ELMfree). Next shot: lower target density to nl_04=0.3e20 m-2 and lower the pre-programmed valve voltage also. Shot 05 -- Plasma. Good shot. nl_04=3-4e19 m-2 target, rising to 6e19 m-2 during the RF just before H-mode. Prf ramps from 1.5 to 2.8 MW. Got a short H-mode at the highest power. H/D is noisy (because of the low signals), and varies up to 12% Next shot: take 1 ms off pre-fill puff. Turn RF power on high right from the start. Shot 06 -- Plasma. Good shot. Target nl_04=3e19 m-2. These have to be the weirdest H-modes I've ever seen. Core x-ray brightness is saturating at 150 kW/m2 (Peak xray emissivity about 1.5-2 MW/m3 !!) Amanda likes this. Prf=2.6-2.9 MW. H/D=10% There's a small glowing spot showing up on the inboard wall midplane at J or K. My guess is it's a broken tile. Next shot: enable DNB gate valve. DNB will fire after t=1.4 s. Add 0.3 mT to Br0. Shot 07 -- Plasma. Good shot. Only one transmitter fired. No H-modes. nl_04=3-3.5e19 m-2. Next shot: Try RF again. Decrease pre-fill by 1 ms again, increase IC_EF4 by +5 amps. Shot 08 -- Plasma. Disrupted at t=1.25 s. I think it's due to an injection at t=1.24 s. Target nl_04=2.9e19 m-2. Prf=2.8 MW. Next shot: increase nl_04 to 4e19 m-2. Decrease pre-fill by another 1 ms. Shot 09 -- Plasma. Good shot. Target nl_04=4e19 m-2. More of these little ratty H-modes. And lots of core x-ray emissivity. John Rice confirms that there's loads of molybdenum. Prf=2.8 MW. Next shot: increase target density to nl_04=5e19 m-2. Shot 10 -- Plasma. Good shot. Target nl_04=5e19 m-2. First H-mode was a nice ELMfree one. Prf=2.8 MW. Next shot: repeat, and set up some fast windows on magnetics, PCI, reflectometer, and xtomo starting at t=0.6 s. Shot 11 -- Plasma. Good shot. Looks like a repeat of the previous shot. First H-mode is ELMfree. Next shot: increase target nl_04 to 6e19 m-2. Shot 12 -- Plasma. Good shot. Some ELMfree H-modes, some EDA H-modes. H/D=8-12%. Prf=2.7 MW. Next shot: increase target density to nl_04=0.7e20 m-2. Shot 13 -- Plasma. Good shot. Looks like all EDA H-modes, as Amanda anticipated. Next shot: decrease target density back to nl_04=0.6e20 m-2 (as on shot 12) and look for ELMfree H-mode to reappear. Shot 14 -- Plasma. Good shot. Might be an ELMfree H-mode on this one. RF was ramped from 1.0 to 2.8 MW. Target nl_04=0.6e20 m-2. Next shot: set Prf to 2 MW (steady) Shot 15 -- Plasma. Good shot. Prf=2.0 MW from t=0.55 to 1.40 s. H/D=10-11%. Next shot: Raise target density to nl_04=0.8e20 m-2. Also, ramp the RF up to 2.8 MW. Shot 16 -- Plasma. Good shot. Prf ramps from 1.0 to 2.8 MW. Next shot: Raise target density to nl_04=0.9e20 m-2. Shot 17 -- Plasma. Good shot. One long EDA H-mode. There was an injection at t=1.2 s which degrades things somewhat. The bright spot on the inboard wall has not been seen since we started raising the density several shots ago. Chris Boswell has magnified the CCD image and has determined that the bright spot spanned parts of two tiles, and therefore it's probably not a broken tile. Chris also noticed that the K-port midplane limiter was getting very bright, so he's convinced me that the bright spot on the inboard wall was actually a specular reflection of a hot spot on the K-port midplane limiter. At the higher densities, the limiter is not being heated as much. Next shot: raise target density to nl_04=1.1e20 m-2 Shot 18 -- Plasma. Good shot. No H-modes. Only had E-port transmitter, Prf <= 1.0 MW. Target nl_04=1.0e20 m-2. Next shot: repeat with both RF transmitters. Shot 19 -- Plasma. Good shot. One long steady EDA H-mode. H/D=9%. Prf ramped up to 2.5 MW. Next shot: increase Ip to 1.0 MA and decrease nl_04 to 0.6e20 m-2. Shot 20 -- Plasma. Good shot. Ip=1.0 MA. Target nl_04=6.7e19 m-2. First H-mode looks ELMfree. Prf ramps from 1.0 to 2.3 MW. The ELMfree H-mode occurs much earlier in the RF ramp, so it's obvious that the higher current gets H-mode at a lower power threshold. Next shot: no PCS changes. Tune RF. Shot 21 -- Plasma. Good shot. Prf=2.6 MW, but it faulted early. 2 H-modes. H/D=10%. Next shot: decrease nl_04 to 0.5e20 m-2. Also add -5 amps to IC_EF4. Shot 22 -- Plasma. Good shot. First H-mode is ELMfree. Prf=2.6 MW. H/D=10-12%, but it's noisy. Next shot: raise nl_04 to 0.7e20 m-2. Shot 23 -- Plasma. Good shot. Target nl_04=0.75-0.8e20 m-2. First H-mode is between ELMfree and EDA. Prf=2.5 MW. H/D=10-12% Next shot: no PCS changes. We are now doing between-shot ECDC in D2 for 8 minutes. Shot 24 -- Plasma. Good shot. Target nl_04=0.8e20 m-2. All the H-modes are EDA. RF faulted very early. Next shot: raise density to nl_04=0.9e20 m-2. No between-shot ECDC. Shot 25 -- Fizzle! Fields and pressure look as good as on any other shot. End of run |
| Session Leader Comments | |||
| Sep 14 2000 11:04:39:340AM | 1000914002 | Amanda Hubbard | nel_01 5.2e19; only 1.1 MW RF. L-mode |
| Sep 14 2000 11:03:15:763AM | 1000914003 | Amanda Hubbard | Late H-mode 1.2 sec; took 2.1 MW power. nel-01 0.6e19m-2. Brief ELM-free period, evolving to EDA. Too late for fluctuation data. Need to raise RF power earlier. |
| Sep 14 2000 11:01:02:327AM | 1000914004 | Amanda Hubbard | H-mode; took 2.6 MW power. nel-01 0.8-1.6e19m-2. Brief ELM-free period, evolving to EDA. Confirmed by fluctuation data. Need to reduce ne some more |
| Sep 14 2000 10:31:37:577AM | 1000914005 | Amanda Hubbard | Dropped density to nel_1 ~6e19m-2. Got very late H-mode; it took 2.8 MW! Looks like it starts ELM-free, with periods of ELMs or EDA. Too late for fluctuation data. |
| Sep 14 2000 10:49:09:983AM | 1000914006 | Amanda Hubbard | Despite Bob's rude comments, this shot did what I hoped. A series of several ELM-free H-mode was followed by one with EDA (and higher starting nel~8e19). This was confirmed by very clear fluctuation signals on the PCI and reflectometer. Radiation, however, went up fast in ELM-free, eroding the pedestals. Repeat this one. |
| Sep 15 2000 02:45:37:840PM | 1000914007 | Amanda Hubbard | Lower RF power; L-mode |
| Sep 14 2000 11:25:13:513AM | 1000914008 | Amanda Hubbard | Starting density is down to 3e19m-3. H-modes are getting very unclear; hardly any density response, and just a brief Te rise. Still core Te's up to 4keV! For next shots, start slowly raising density. nel 4e19 for shot 9 |
| Sep 14 2000 11:55:36:733AM | 1000914009 | Amanda Hubbard | Starting density 4e19m-3. UP TO 5keV early in shot. RF still doing nicely, ~ 3 MW. A number of H-modes, but very short, not clear on type. Early ones have te8 to 800 eV, little ne rise. Later ones have ne rise, but modest Tedge. |
| Sep 15 2000 02:46:46:873PM | 1000914010 | Amanda Hubbard | Starting density 5e19m-3. Got a nice, longer ELM-free H-mode early (0.61 -0.68 seconds). Impressive pedestal. Te8 to 900 eV. Te0 to 4.8 keV. There is some saturation on MIchelson and GPC Ch 2; has probably been there a few shots. Repeat, moving various fluctuation diagnostics earlier to look for any ELMs (none apparent) |
| Sep 15 2000 02:48:42:013PM | 1000914011 | Amanda Hubbard | Repeat shot 10, increasing power earlier to move H-mode earlier. Similar ELM-free H-mode, with NO edge fluctuations on PCI or reflectometer. |
| Sep 14 2000 01:03:10:810PM | 1000914012 | Amanda Hubbard | Starting density 6e19m-3. Series of decent H-modes. Ist ELM-free, just a hint of fluctuations late 2nd slight D-alpha rise, weak fluctn appears 3rd more EDA. All appears to confirm role of target density in fluctns as well as Dalpha. |
| Sep 14 2000 03:32:02:793PM | 1000914013 | Amanda Hubbard | Starting density 7e19m-3. Still nice steady RF. Series of decent H-modes. All are now EDA, based on both D-alpha and PCI fluctuation, which is MUCH stronger than on shot 6. Looks like we've found our EDA threshold! Particle transport Next shot; back to target 6e19 m-3 ramping RF power, |
| Sep 14 2000 03:47:32:500PM | 1000914014 | Amanda Hubbard | Back to starting density 6e19m-3. RF power ramped. Threshold 1.8 MW; still high. 2 H-modes. The first shows a hint of fluctuations on PCI, mainly ELM-free. 2nd EDA |
| Sep 14 2000 03:48:39:437PM | 1000914015 | Amanda Hubbard | Back to starting density 6e19m-3. RF power reduced to 2 MW. Not very different from higher power; a weak hint of EDA fluctuations, a bit higher D-alpha. Next shot: target 8e19, power ramped. |
| Sep 14 2000 03:49:40:873PM | 1000914016 | Amanda Hubbard | Starting density 8e19m-3. RF power ramped 1-2.8 MW, as requested, Two H-modes, both EDA but the second is much steadier. Interestingly, PCI shows fluctuations are weaker in the first, and only start after a delay. The second, steadier EDA has much stronger fluctuations; seems to be a quantitative correlation with particle transport. The bad news is energy transport is also dropping; only H~1.3 vs 2.5 early in day. |
| Sep 14 2000 03:52:04:733PM | 1000914017 | Amanda Hubbard | Starting density 9e19m-3. RF power ramped 1-2.8 MW, as requested, One long, quite steady EDA. |
| Sep 14 2000 03:52:52:187PM | 1000914018 | Amanda Hubbard | Starting density 1.1e19m-3. RF power lower; L-mode. |
| Sep 14 2000 03:51:26:340PM | 1000914019 | Amanda Hubbard | Target 1.1e19. Ramped RF, steady EDA. This finished 800 kA density scan. Now go to 1 MA, low density. |
| Sep 14 2000 03:50:50:903PM | 1000914020 | Amanda Hubbard | 1 MA. Target 6e19m-2. Ramped RF. Nice series of H-modes. 1st is ELM-free, no PCI fluctuation. 2nd is EDA, clear fluctuation. Next shot: same density, steady RF. |
| Sep 14 2000 04:12:31:780PM | 1000914021 | Amanda Hubbard | Target still 6e19 m-2; actual a bit higher? Level 2.6 MW; some trips late. 2 H-modes, type not so clear. ELM-free or weak eda?? Lower target for next shot. |
| Sep 14 2000 04:14:34:607PM | 1000914022 | Amanda Hubbard | Target 5e19. 2 H-modes. 1st definitely ELM-free. No fluctuations, Te8 840 eV, 180 kJ Later Weak EDA (late fluctns); Teped 413 eV, 114 kJ. Much lower confinement in EDA, all day. |
| Sep 14 2000 04:34:49:670PM | 1000914023 | Amanda Hubbard | Target 7e19. 4 H-modes. 1st still looks fairly ELM-free; possibly weak EDA Te8 730 eV, 173 kJ Later EDA H-modes; Teped 385 eV, 132 kJ. |
| Sep 14 2000 05:45:17:670PM | 1000914024 | Amanda Hubbard | Target 7e19. Did between shot ECDC. H-mode Looks a bit more EDAish, but still weak. RF trips early,. |
| Physics Operator Comments | |||
| Sep 13 2000 06:18:21:733PM | Robert Granetz | Engineering setup for Thursday, 14 September 2000: Overnight ECDC in HELIUM, stopping 1-2 hours prior to the run. Run begins at 9:00 and ends at 17:00. Power system setup as on 1000913002. Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid enabled fill B-side upper with 35 psi of He Hybrid DISABLED (Yes, HELIUM) (available for between-shot ECDC) fill C-side with 30 psi of D2 Hybrid enabled leave J-bottom as is Hybrid DISABLED The following gate valves should be enabled, assuming no vacuum problems: ECE, VUV DNB gate valve will be DISABLED for the beginning of the run; may enable later. | |
| Sep 13 2000 06:18:54:107PM | Robert Granetz | Run plan for Thursday, 14 September 2000: MP 278 -- ELMs and EDA in low density H-modes Session leader: Amanda Hubbard Physics operator: R. Granetz Goals: Clarify the role of density on the EDA/ELM-free boundary. Investigate the ELMs previously observed in low density operation. Shot sequence: 1) Start at 0.8 MA, 5.4 T, nl_04=0.5e20 m-2. RF ramped to 1.5 MW. ELM-free H-mode is anticipated at this low density. If it's EDA instead, then lower density some more. 2) Increase Prf, shot-to-shot. Look for ELMs and trends in grad-P (5 shots) 3) Slowly increase nl_04 to 1e20 m-2. Monitor EDA signatures, especially fluctuations. At each density, use 1 slow Prf ramp (to give L-H threshold and time evolution) and 1-2 shots with higher, fixed Prf to maximize grad-P and chance of triggering ELMs. Anticipate 5 densities, 2-3 shots each (15 shots) 4) If time permits, raise Ip to 1 MA (where EDA is more marginal) and repeat part of density scan to see if there is a "fixed" density limit or if there is an interdependence of q and ne. | |
| Sep 14 2000 08:28:28:000AM | Robert Granetz | Overnight ECDC in He Hybrid coldstart done; no errors found Loaded shot 1000913005 (segment 1 from 1000913016) and reduced Ip to 0.8 MA and nl_04 to 0.5e20 m-2. Remove waggle in Btor. Add 2 ms to pre-fill puff. | |
| Sep 14 2000 09:08:19:560AM | 1000914001 | Robert Granetz | Shot 01 -- Fizzle. Pre-fill pressure was too low (due to He ECDC). Main video cameras have no synch signal. Jim Terry needs cell access to fix. Next shot: add 5 ms to pre-fill puff. |
| Sep 14 2000 09:36:17:717AM | 1000914002 | Robert Granetz | Shot 02 -- Plasma. Good shot. Ip=0.8 MA, Bt=5.4 T, nl_04=0.5e20 m-2, as requested. RF ramped, but started faulting around 1 MW. There was some heating, but no H-mode. Next shot: lower Br0 by 0.5 mT and increase IC_EF4 by +10 amps. Try for a little higher RF power. |
| Sep 14 2000 09:49:18:543AM | 1000914003 | Robert Granetz | Shot 03 -- Plasma. Good shot. nl_04=5.5-6e20 m-2. Got an H-mode which briefly started as ELMfree before changing to EDA. Prf ramped up to 2.0 MW and then leveled off. Pthreshold=2 MW. Strike point is almost on the floor. Next shot: raise ZXL by 5 mm. Ramp RF to 2 MW earlier in the shot. |
| Sep 14 2000 10:11:39:500AM | 1000914004 | Robert Granetz | Shot 04 -- Plasma. Good shot. nl_04=0.7e20 m-2. The increase in the density is coming from the RF. EDA H-mode (starting briefly as ELMfree). Next shot: lower target density to nl_04=0.3e20 m-2 and lower the pre-programmed valve voltage also. |
| Sep 14 2000 10:22:31:670AM | 1000914005 | Robert Granetz | Shot 05 -- Plasma. Good shot. nl_04=3-4e19 m-2 target, rising to 6e19 m-2 during the RF just before H-mode. Prf ramps from 1.5 to 2.8 MW. Got a short H-mode at the highest power. H/D is noisy (because of the low signals), and varies up to 12% Next shot: take 1 ms off pre-fill puff. Turn RF power on high right from the start. |
| Sep 14 2000 10:55:36:060AM | 1000914006 | Robert Granetz | Shot 06 -- Plasma. Good shot. Target nl_04=3e19 m-2. These have to be the weirdest H-modes I've ever seen. Core x-ray brightness is saturating at 150 kW/m2 (Peak xray emissivity about 1.5-2 MW/m3 !!) Amanda likes this. Prf=2.6-2.9 MW. H/D=10% There's a small glowing spot showing up on the inboard wall midplane at J or K. My guess is it's a broken tile. Next shot: enable DNB gate valve. DNB will fire after t=1.4 s. Add 0.3 mT to Br0. |
| Sep 14 2000 11:02:59:153AM | 1000914007 | Robert Granetz | Shot 07 -- Plasma. Good shot. Only one transmitter fired. No H-modes. nl_04=3-3.5e19 m-2. Next shot: Try RF again. Decrease pre-fill by 1 ms again, increase IC_EF4 by +5 amps. |
| Sep 14 2000 11:32:20:090AM | 1000914008 | Robert Granetz | Shot 08 -- Plasma. Disrupted at t=1.25 s. I think it's due to an injection at t=1.24 s. Target nl_04=2.9e19 m-2. Prf=2.8 MW. Next shot: increase nl_04 to 4e19 m-2. Decrease pre-fill by another 1 ms. |
| Sep 14 2000 12:13:03:687PM | 1000914010 | Robert Granetz | Shot 10 -- Plasma. Good shot. Target nl_04=5e19 m-2. First H-mode was a nice ELMfree one. Prf=2.8 MW. Next shot: repeat, and set up some fast windows on magnetics, PCI, reflectometer, and xtomo starting at t=0.6 s. |
| Sep 14 2000 12:41:30:543PM | 1000914011 | Robert Granetz | Shot 11 -- Plasma. Good shot. Looks like a repeat of the previous shot. First H-mode is ELMfree. Next shot: increase target nl_04 to 6e19 m-2. |
| Sep 14 2000 12:58:36:373PM | 1000914012 | Robert Granetz | Shot 12 -- Plasma. Good shot. Some ELMfree H-modes, some EDA H-modes. H/D=8-12%. Prf=2.7 MW. Next shot: increase target density to nl_04=0.7e20 m-2. |
| Sep 14 2000 01:13:38:280PM | 1000914013 | Robert Granetz | Shot 13 -- Plasma. Good shot. Looks like all EDA H-modes, as Amanda anticipated. Next shot: decrease target density back to nl_04=0.6e20 m-2 (as on shot 12) and look for ELMfree H-mode to reappear. |
| Sep 14 2000 01:30:02:420PM | 1000914014 | Robert Granetz | Shot 14 -- Plasma. Good shot. Might be an ELMfree H-mode on this one. RF was ramped from 1.0 to 2.8 MW. Target nl_04=0.6e20 m-2. Next shot: set Prf to 2 MW (steady) |
| Sep 14 2000 01:58:38:450PM | 1000914015 | Robert Granetz | Shot 15 -- Plasma. Good shot. Prf=2.0 MW from t=0.55 to 1.40 s. H/D=10-11%. Next shot: Raise target density to nl_04=0.8e20 m-2. Also, ramp the RF up to 2.8 MW. |
| Sep 14 2000 02:02:15:513PM | 1000914016 | Robert Granetz | Shot 16 -- Plasma. Good shot. Prf ramps from 1.0 to 2.8 MW. Next shot: Raise target density to nl_04=0.9e20 m-2. |
| Sep 14 2000 02:25:06:310PM | 1000914017 | Robert Granetz | Shot 17 -- Plasma. Good shot. One long EDA H-mode. There was an injection at t=1.2 s which degrades things somewhat. The bright spot on the inboard wall has not been seen since we started raising the density several shots ago. Chris Boswell has magnified the CCD image and has determined that the bright spot spanned parts of two tiles, and therefore it's probably not a broken tile. Chris also noticed that the K-port midplane limiter was getting very bright, so he's convinced me that the bright spot on the inboard wall was actually a specular reflection of a hot spot on the K-port midplane limiter. At the higher densities, the limiter is not being heated as much. Next shot: raise target density to nl_04=1.1e20 m-2 |
| Sep 14 2000 02:47:12:153PM | 1000914018 | Robert Granetz | Shot 18 -- Plasma. Good shot. No H-modes. Only had E-port transmitter, Prf <= 1.0 MW. Target nl_04=1.0e20 m-2. Next shot: repeat with both RF transmitters. |
| Sep 14 2000 03:05:13:217PM | 1000914019 | Robert Granetz | Shot 19 -- Plasma. Good shot. One long steady EDA H-mode. H/D=9%. Prf ramped up to 2.5 MW. Next shot: increase Ip to 1.0 MA and decrease nl_04 to 0.6e20 m-2. |
| Sep 14 2000 03:23:30:357PM | 1000914020 | Robert Granetz | Shot 20 -- Plasma. Good shot. Ip=1.0 MA. Target nl_04=6.7e19 m-2. First H-mode looks ELMfree. Prf ramps from 1.0 to 2.3 MW. The ELMfree H-mode occurs much earlier in the RF ramp, so it's obvious that the higher current gets H-mode at a lower power threshold. Next shot: no PCS changes. Tune RF. |
| Sep 14 2000 03:43:24:840PM | 1000914021 | Robert Granetz | Shot 21 -- Plasma. Good shot. Prf=2.6 MW, but it faulted early. 2 H-modes. H/D=10%. Next shot: decrease nl_04 to 0.5e20 m-2. Also add -5 amps to IC_EF4. |
| Sep 14 2000 04:03:25:233PM | 1000914022 | Robert Granetz | Shot 22 -- Plasma. Good shot. First H-mode is ELMfree. Prf=2.6 MW. H/D=10-12%, but it's noisy. Next shot: raise nl_04 to 0.7e20 m-2. |
| Sep 14 2000 04:26:44:903PM | 1000914023 | Robert Granetz | Shot 23 -- Plasma. Good shot. Target nl_04=0.75-0.8e20 m-2. First H-mode is between ELMfree and EDA. Prf=2.5 MW. H/D=10-12% Next shot: no PCS changes. We are now doing between-shot ECDC in D2 for 8 minutes. |
| Sep 14 2000 05:21:17:200PM | 1000914025 | Robert Granetz | Shot 25 -- Fizzle! Fields and pressure look as good as on any other shot. End of run |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:59:42:670AM | Plasma | Ok | |
| 2 | 09:13:17:873AM | Plasma | Ok | |
| 3 | 09:34:39:327AM | Plasma | Ok | |
| 4 | 09:49:41:217AM | Plasma | Ok | |
| 5 | 10:08:13:763AM | Plasma | Ok | |
| 6 | 10:24:09:373AM | Plasma | Ok | |
| 7 | 10:53:36:000AM | Plasma | Ok | |
| 8 | 11:07:58:403AM | Plasma | Ok | |
| 9 | 11:31:51:013AM | Plasma | Ok | |
| 10 | 11:53:09:763AM | Plasma | Ok | |
| 11 | 12:23:49:920PM | Plasma | Ok | |
| 12 | 12:39:34:890PM | Plasma | Ok | |
| 13 | 01:00:03:687PM | Plasma | Ok | |
| 14 | 01:16:56:263PM | Plasma | Ok | |
| 15 | 01:35:57:500PM | Plasma | Ok | |
| 16 | 01:53:00:327PM | Plasma | Ok | |
| 17 | 02:13:05:200PM | Plasma | Ok | |
| 18 | 02:32:58:793PM | Plasma | Ok | |
| 19 | 02:51:07:920PM | Plasma | Ok | |
| 20 | 03:12:41:483PM | Plasma | Ok | |
| 21 | 03:32:14:140PM | Plasma | Ok | |
| 22 | 03:52:39:280PM | Plasma | Ok | |
| 23 | 04:12:36:687PM | Plasma | Ok | |
| 24 | 04:34:19:513PM | Plasma | Ok | |
| 25 | 04:54:27:280PM | Plasma | Ok | |