Miniproposal:267
Date Filed: 4/4/2000
Title:Dependence of SOL Fluctuations and Particle Transport on Collisionality
First Author:Brian Labombard
Session Leader:Brian Labombard (shots 1-6)

Operators
Session leader(s):Brian Labombard
Physics operator(s):Bill Rowan
Engineering operator(s):Gary Dekow

Engineering Operator Run Comment
MP#267 - NL scan with reversed Bt and Ip SL: LaBombard PO: Rowan EO:Deko

Session Leader Plans

Physics Operators Plans

Session Leader Summaries

Physics Operator Summaries

Session Leader Comments
Nov 14 2000 09:28:27:230AM1001114001Brian LabombardShot 1 - 1.0 MA, NL04 ~ 1.0, Bt = 5.3
ASP setup for today: N-S in Vf mode, E-W in single probe sweep mode
Reduced bias voltage on East probe (still has a shorting problem)
FSP setup for today: N-S in Vf mode, E-W in SINGLE probe sweep mode
(double sweep power supply is dead)
ASP and FSP scanning at 0.7, 0.95, and 1.2 seconds in far sol
C2D4 plumes.

Next Shot: dial up 0.8 MA, NL04=0.6 and ramp Bt down to 4 tesla for time period 0.7 to 1.2 seconds

Physics Operator Comments
Nov 14 2000 08:52:07:843AMBill RowanEngineering Setup for Tuesday, November 14

MP#267 - NL scan with reversed Bt and Ip
SL: LaBombard
PO: Rowan

Engineering setup:
-------------------
Overnight ECDC in D2, stopping 1-2 hours before run.

Run begins 9:00 and ends at 17:00

Power System Setup: Same as on 1001109022

Gas setup - fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid DISABLED
fill B-side upper with 35 psi of D2 Hybrid DISABLED, for ECDC
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bottom as is Hybrid DISABLED

The following gate valves should be enabled, assuming no vacuum problems:
ECE, VUV, DNB, Beast

The following transmitters should be turned on 1, 2, and 4

Run Plan (LaBombard)
-------------------
Start with shot#1001109022 which was a recent 1.0 MA, 5.3 tesla,
NL04 = 1.2 discharge (reversed Ip and Bt) with good probe targeting, gaps etc.
Then change plasma current to 0.8 MA, Bt to 4 tesla, and NL04 = 0.6x10^20 m^-2.

Shot#1-3
NL04 = 0.6x10^20 m^-2
Ip = 0.8 MA, Bt = 4 tesla
Setup equilibrium and FSP/ASP target.

Take two shots at each condition to optimize scanning
probe insertion depths.

4,5 - NL04 = 0.6, Ip = 0.8, Bt = 4
6,7 - NL04 = 0.9, Ip = 0.8, Bt = 4
8,9 - NL04 = 1.2, Ip = 0.8, Bt = 4

10,11 - NL04 = 1.2, Ip = 0.8, Bt = 6
12,13 - NL04 = 0.9, Ip = 0.8, Bt = 6
14,15 - NL04 = 0.6, Ip = 0.8, Bt = 6

16,17 - NL04 = 0.5, Ip = 0.53, Bt = 5.3
18,19 - NL04 = 0.7, Ip = 0.53, Bt = 5.3
20,21 - NL04 = 0.9, Ip = 0.53, Bt = 5.3

22,23 - NL04 = 1.0, Ip = 1.06, Bt = 5.3
24,25 - NL04 = 1.3, Ip = 1.06, Bt = 5.3
26,27 - NL04 = 0.7, Ip = 1.06, Bt = 5.3


As requested, ECDC ran all night and was turned off at about 7am.

Loaded PCS from shot 1001109022
Did Load/Clean.

Did cold start and completed at 14-NOV-2000 08:30:29.84

Start with a lower density. Reduced NL_04 to 1e+20
Did Load/Clean
Nov 14 2000 09:01:51:560AMBill RowanLate start. Waiting for alternator. Expect first shot at approx 9:15
Nov 14 2000 09:26:47:920AM1001114001Bill Rowan001. Plasma

Next shot.
Reduced TF current from 150000 to 112000 to reduce BT to 4 T
Reduced IP from 1MA to 0.8 MA
Reduced NL_04 from 1e20 to 0.8e20
Nov 14 2000 09:40:23:687AM1001114001Bill RowanComputer problems while in init for 002. Josh resolving.
Nov 14 2000 10:08:04:170AM1001114003Bill Rowan003. Fizzle

Next shot.
Increased prefill by 2 ms
Reduced BR by 0.5 mTs

Engineering Operator Comments
ShotTimeTypeStatusComment
109:11:48:263AMPlasmaOk
309:44:10:200AMPlasmaOk
408:55:21:980PMTestBad
509:35:18:000PMTestBadcamac ack failure
610:11:41:343PMTestBadcamac errors