Alcator C-Mod Run 1001214 Information

Back to runs

Miniproposals
Miniproposal:277a
Date Filed:11/17/2000
Title:Internal Transport Barrier Studies at 4.5T with Simultaneous Central and Off-axis ICRF Heating
First Author:Paul Bonoli
Session Leader:Paul Bonoli (shots 1-24)

Operators
Session leader(s):Paul Bonoli
Physics operator(s):Steve Wolfe
Engineering operator(s):Ed Fitzgerald

Engineering Operator Run Comment
MP#277A Two freq heating and ITB Physics SL:Bonoli PO:Wolf EO:Fitzgerald

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:26:053PM
Author: To Be Determined
Run Summary for Thursday - December 14, 2000

Mini-proposal No. 277A: Internal Transport Barrier Studies at 4.5T
with Simultaneous Central and Off-axis ICRF
Heating
1001214

Physics Operator: Steve Wolfe
Session Leader: Paul Bonoli

____________________________________________________________________________

Run Summary

____________________________________________________________________________

This was a somewhat frustrating run day, although we did obtain some
interesting results: For example on shot 001 an EDA H-mode was
obtained with about 400 kW of central heating from the 70 MHz ICRF
system alone. Also on shot 015 we obtained a significant increase in
the neutron rate (factor of 2) and an increase in stored energy when
the 70 MHz ICRF power was overlapped for 200 msec with the 80 MHz
off-axis heating power in a density barrier mode. Difficulties were
experienced later in the run (see shots 018-024) in producing the
density barrier mode reliably because of a significant time delay in
the transition to an EDA H-mode. The 70 MHz power from J-port was also
limited to about 600-800 kW because of arcing in the J-port
transmission line system.

On shots 001-012, the 70 MHz heating power was turned on alone from
(0.6 - 1.5) sec. This part of the run plan was intended to establish
that the J-port system was heating the central plasma effectively.
A low power threshold (about 400 kW) was found to get the plasma into
a slightly delayed EDA H-mode (see shot 001 for example). At higher
power (about 800 kW), core electron heating from the (H) minority tail
could also be seen on the central GPC channel (see shot 004). At
about 600 kW and higher, the J-port system shut down because of faults
related to arcing in the transmission line system.

On shots 013-018, 2 MW of 80 MHz off-axis ICRF power (D & E ports)
was turned on from 0.7 - 1.5 sec. The J-port power was turned on from
1.3-1.5 sec. at levels ranging from 700-850 kW. Perhaps the "best"
discharge in this sequence is shot 015 where J-port stayed on for its
entire pulse as its power ramped up to 700 kW. [Using powers higher
than this caused faults.] On shot 015 a density barrier mode was
established with the 80 MHz heating and ne0_TS increased to 3.8 X10^20
before the J-port turn-on. At the J-port turn-on, the density rise
"arrested" itself. However, the neutron rate more than doubled from
4.2 X10^12 to 9 X 10^12. Also the stored energy increased from about
85 kJ to almost 100 kJ and Te(0) increased (from GPC). Although the
density stopped increasing when the 70 MHz power was applied, it may be
that an improved confinement mode with a thermal barrier still exists
and the barrier is simply "leaking" more. Indeed the increased neutron
rate and central electron heating that was observed during application
of the 70 MHz power may be indicative of heating inside a thermal
barrier. This can be tested by revisiting shots 013-018 with more
ICRF power from J-port and measuring the ion temperature profile with
HIREX.

During the remainder of the run (shots 019-024) we intended to vary
the power levels and relative timings of the 80 and 70 MHz ICRF
powers. This part of the run plan was not carried out however, because
of difficulties in producing the density barrier mode. Typically, the
transition to an EDA type H-mode would occur around 1.1-1.2 sec. and
might be preceeded by an ELM-free H-mode phase.


Physics Operator Summaries
Entered: Jul 7 2004 04:37:12:850PM
Author: To Be Determined
Physics Operator Summary for Thursday, Dec 14, 2000

MP#277A Internal Transport Barrier Studies at 4.5~T with Simultaneous Central and Off-axis ICRF Heating
SL: Bonoli
PO: wolfe
EO: Fitzgerald,

The run is scheduled to begin at 07:30 and end at 15:30 to allow people to get
to the PSFC Holiday Party.

Plan:
=====
ECDC in D2 overnight, ending at least one hour before start of run

Power systems as on 1001213001

Gas Setup:
fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid enabled
fill B-side upper with 35 psi of D2 Hybrid DISABLED, for ECDC
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bot as is Hybrid DISABLED

Enable the following gate valves: ECE, VUV, DNB

RF Setup: XMTRs 1,2, and 4 should be made ready for operation by 7:00

Plan:

We will continue with the two-frequency heating experiment from where it left
off on Wednesday, and get as far as we can.

This is a continuation of the "2 day run plan" posted for 1001212.
We will start the day injecting only the 70 MHz ICRF power into

plasmas at 4.5 T in order to produce ICRF heated H-modes at 4.5 T.
Shots will be required to bring the ICRF power levels up from
the 500-600 kW level of Wednesday (1001213). We will then proceed
on to the simultaneous injection of ICRF power at 70 and 80 MHz in
an attempt to heat (on-axis) the density barrier mode.

A proposed shot sequence is given below:

(a) Establish an ICRF heated H-mode at 4.5~T with central
ICRF heating only (70~MHz and 1.5-2~MW). (10-15 shots)

(i) Use about 10-12 shots to bring up ICRF power at 70 MHz
and establish H-mode at 4.5 T.

(ii) Measure central electron temperature heating using GPC
in (i).

(iii) Investigate power threshold for H-mode in (i).
(b) Apply both frequencies at 4.5~T using 2~MW at each frequency.
Look for thermal energy barrier formation. Investigate the
effect of turning the 70 MHz power on at different times and
power levels in order to sustain and successfully heat the
barrier mode during two-frequency injection. (10-15 shots)

(i) Measure T_i profile and poloidal rotation profile using
HIREX over a 4 shot sequence once an acceptable two-
frequency ITB is established.
(ii) Measure N_e profile from visible bremsstrahlung
(iii) Measure T_i(0) from neutrons and T_e(0) from Thomson
scattering.


Note that we have started from a segment 2 originally run in June, which does
not have the more recent offset values on CLEARIN and RCUR (12700 and 0,
respectively). Therefore, the gaps will change significantly if we change
current. However, since only 800kA shots are called for in the run plan, I
will not take run time to tune up a corrected predictor set.

Results:
========

The run started on time at 7:30, and the shot rate was good, until we got held
up for an hour by a data system hang (file lock) after shot 5. Josh cleared it
after he got in from a weather-delayed commute.

We started with the same shot as the last one on Wednesday, except for
lowering the argon puff to 30msec (from 50 !), and slightly lower RF power
from J-port (70MHz). The first series of shots were used to bring up the 70MHz
power. All of these got into H-mode. There were only a few PCS tweaks during
these shots, a couple in seg 1 and some gap adjustment in seg 2. We took 12
shots with only J, but were unable to get above 1.05MW.

We then moved on to part b, with D&E (80MHz) on early and J (70MHz) at 1.3
sec. The core barrier formation was poor and non-reproducible. The H-mode
start was delayed until .9 or 1.0 sec (RF on at .7). Starting the RF pulse at
0.5sec and 2.5MW (shot 20) produced an early H-mode, and a disruption at
1sec. Susequent shots at 2MW with the same timing had H-modes delayed to
between .9 and 1.05sec. We changed field between 4.4 and 4.6T, without obvious
effect. Turning off the DNB (shot 23) did not help. Reloading shot 1001213016,
which had an early H-mode and strong peaking, did not help either (shot 24),
although JR reported that the Mo was down by a factor of 3 relative to earlier
in the day. As a result of the lack of prompt L-H transitions and the general
lack of ITB formation we made essentially NO progress on part b of the plan.

The most promising shot in the second phase of the run was #17, which had some
peaking, and also exhibited a strong MHD mode that lasted for much of the
shot. This looked like an m=1 snake on the xrays; note that Ian pointed out
that the xray signals are aliased on this oscillation, which was actually
around 5kHz as seen on ECE.

Note that the last shot was based on shot 16 from Wednesday, and has a 50msec
Ar puff and moving outer gap. Also, this shot has the tf rampdown starting at
1.4 sec, instead of 1.5, which I had remedied on shot 18.

The machine ran well today, with only one fizzle (shot 6). Current rise was
generally fast, and the plasma moved out some, but only bounced on shots 5 and
6. I adjusted the pre-puff several times, and increased the segment 1 RCUR
offset from 5500 to 6500 to keep the outward motion under control.

There were no power system problems today.

We had two data system hangs, a file lock problem after shot 5 and a server
hang on the video_camera storage after shot 17. On shot 20, the bus rogowski
data didn't come through, with a "device not triggered" error; I stored this
module (INCAA_1) manually. We had a similar problem yesterday, and it was
discovered that the dig frequency was at too low a value, causing the data to
still be being taken at the pulse- recool transition. We may need to delay the
sequence number (presently 30) of the store action on this module.

Cooling was relatively fast all day, with a shot cycle of ~12 minutes in the
morning, slowing to ~15-17min by the end of the day.

The DNB was firing from shot 6 on, at .5sec until shot 19, then at .3 sec,
except for shot 23 when they were asked to refrain; there were no obvious
deleterious effects.

The tokamak does not seem to mind getting started early. However, it is not
clear that what got accomplished was worth the loss of sleep.

Scorecard:
----------

Tests 0
Duds 0
Fizzles 1
Plasmas 23
------- --
Shots 24


Session Leader Comments
Dec 14 2000 07:57:17:280AM1001214001Paul Bonoli1001214001

Request: Wa I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port (70 MHz) turned on - ramp up to 500 kW

Result: Plasma - nice H-mode at 0.94 sec.
J - port ran through with no faults.
No HIREX (turn on Argon puff)
Raise ICRF power next shot
Dec 14 2000 07:57:56:623AM1001214002Paul Bonoli1001214002

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 700 kW

Result: Plasma - H-mode again at 0.99 sec.
J - port ran with one faults.
Raise ICRF power again on next shot
Some evidence od density peaking after the rf
turns off.
Dec 14 2000 08:12:36:623AM1001214003Paul Bonoli1001214003

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 900 kW

Result: Plasma - H-mode at 0.85 sec.
J - port ran to 0.85 sec. and then failed on re-tries.
H/D = 0.04
Some indication of central electron heating by ICRF on GPC
Take shot again at same power level -> keep plasma - antenna
gap more constant.
Dec 14 2000 08:26:10:700AM1001214004Paul Bonoli1001214004

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1 Mw

Result: Plasma - H-mode at 0.84 sec.
J - port ran through after recovering from trips at 0.92 sec.
H/D = 0.04
Increase ICRF power again by 200 kW
Dec 14 2000 08:46:25:530AM1001214005Paul Bonoli1001214005

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Plasma - H-mode from 0.73 to 0.93 sec.
J - port ran to 0.73 sec (0.95 MW) and faulted out.
H/D = 0.04
Take shot over again at same ICRf power (1.2 MW)
Dec 14 2000 09:51:31:000AM1001214006Paul Bonoli1001214006 - One hour delay because dtata system was hung up

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Fizzle -
Dec 14 2000 10:09:56:873AM1001214007Paul Bonoli1001214007

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Plasma with H-mode, but ICRF faults out at 0.78 sec.
Steve Wukitch believes this may be a conditioning problem -
we will take more shots at this power level since
the ICRF power is staying on longer during the re-tries.
Dec 14 2000 10:37:23:967AM1001214008Paul Bonoli1001214008

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Plasma with H-mode.
H-mode transition occurs at 0.83 sec. with 750 kW of ICRF power.
ICRF again faults out at 1.06 sec. and then shuts off after
multiple re-tries.
Dec 14 2000 10:51:43:233AM1001214009Paul Bonoli1001214009

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Plasma with H-mode - similar to shot 008
H-mode transition again occurs at 0.83 sec.
ICRF shuts off after multiple faults - install a 3 db
attenuator in the fault detection circuit for J-port.
Dec 14 2000 11:01:32:890AM1001214010Paul Bonoli1001214010

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Plasma with two H-modes
J-port ran through now with fault recovery.
Raise ICRF power to 1.4 MW next shot.
Dec 14 2000 11:20:48:827AM1001214011Paul Bonoli1001214011

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.4 Mw

Result: Plasma with H-mode at 0.80 sec.
J-port faulted at L-H transition.
Increase plasma - antenna gap by a few millimeters
and back off on ICRF power.
Dec 14 2000 11:43:05:170AM1001214012Paul Bonoli1001214012

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) shut off
J-port - ramp up to 1.2 Mw

Result: Plasma with H-mode, but rf faults occurred again
Time to move on to two-frequency shots.

Dec 14 2000 12:42:10:890PM1001214013Paul Bonoli1001214013

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (0.5 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Plasma with two H-modes - not a clear density barrier yet.
D and E ran through
J ran through with faults.
Raise D and E - powers by 0.25 MW / port

Dec 14 2000 12:41:35:560PM1001214014Paul Bonoli1001214014

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (0.75 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Interesting shot - plasma went into H-mode (delayed).
When J-port turns on neutrons increase to 8 X 10^12 ! - it seems we
may have done some heating inside the plasma core.
D and E ran through
J ran through with only a single trip.
Raise D and E - powers by 0.25 MW / port

Dec 14 2000 01:03:30:687PM1001214015Paul Bonoli1001214015

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.0 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Interesting shot again - plasma went into H-mode (delayed only to 0.9 sec)
When J-port turns on neutrons increase to 8 X 10^12 ! - it seems we
may have done some heating inside the plasma core.
D and E ran through
J ran through also.
Take shot again since clear density peaking still not observed.


Dec 14 2000 12:55:07:140PM1001214016Paul Bonoli1001214016

Request: I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.0 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Interesting - plasma went into H-mode (delayed again to 0.9 sec)
When J-port turns on neutrons increase to 1 X 10^13 ! - it seems we
may have done some heating inside.
D and E ran through
J ran through also.
Still no clear indiciation of density peaking.
Reduce B_t to 4.4 T to see if density peaking comes back.


Dec 14 2000 01:38:33:530PM1001214017Paul Bonoli1001214017


Request: I_p = 800 kA, B_t = 4.4 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.0 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Interesting - plasma went into H-mode.
More density peaking - NROOT_zeff = 6.3 X 10^20
D and E ran through
J ran with some faults.
This looked pretty good - take the shot again.




Dec 14 2000 01:51:11:607PM1001214018Paul Bonoli1001214018


Request: I_p = 800 kA, B_t = 4.4 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.0 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Got delayed H-mode.
No density peaking on this shot.
D and E ran through
J ran with some faults.
Try raising the D & E power on the next shot to 2.5 MW total




Dec 14 2000 02:07:20:013PM1001214019Paul Bonoli1001214019


Request: I_p = 800 kA, B_t = 4.4 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.25 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.7 MW).

Result: Got delayed H-mode.
No density peaking on this shot either.
D ran to 1.04 sec and faulted out.
E ran through
J ran with nicely
Turn rf on at 0.5 sec to remedy late H_mode transition
Raise J-port power


Dec 14 2000 02:22:47:513PM1001214020Paul Bonoli1001214020


Request: I_p = 800 kA, B_t = 4.4 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.25 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.8 MW).


Results: Got the early H-mode - finally! But the plasma disrupted at 1.0 sec
because of impurity influx from E-port (we think). Back off on
on total ICRF power to 2.0 MW and keep timing the same (turn on
D and E prots at 0.5 sec.).

Dec 14 2000 02:41:27:077PM1001214021Paul Bonoli1001214021


Request: I_p = 800 kA, B_t = 4.4 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.00 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.8 MW).


Results: Got a delayed H-mode again - but no disruption.
D and E stayed on, but J had multiple faults.
Go back to 4.6 T in hopes that it will be easier to
get the plasma into EDA H-mode.


Dec 14 2000 02:47:51:090PM1001214022Paul Bonoli1001214022


Request: I_p = 800 kA, B_t = 4.6 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.00 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.8 MW).


Results: Got a delayed H-mode again - but no disruption.
D and E stayed on, but J had multiple faults.
Go back to 4.6 T in hopes that it will be easier to
get the plasma into EDA H-mode.


Dec 14 2000 03:16:07:280PM1001214023Paul Bonoli1001214023


Request: I_p = 800 kA, B_t = 4.6 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.5 sec. (1.00 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.8 MW).
Shut off the DNB to see if that was casuing problems.


Results: Still didn't get early EDA. Instead we got an ELM-free H-mode
and then a transition to an EDA (late).

Dec 14 2000 03:28:54:983PM1001214024Paul Bonoli1001214024

Request: Try loading shot from yesterday when we were getting good
density barrier modes -> Load shot 1001213016
I_p = 800 kA, B_t = 4.5 T, nl_04 = 0.75 (target)
D and E -port (80 MHz) turned on from 0.7 to 1.4 sec. (0.95 MW /port)
J-port - on from 1.3 to 1.5 sec. (0.8 MW).
Turn DNB back on.


Results: We STILL got a delayed EDA H-mode with an ELM-free phase first.

Physics Operator Comments
Dec 14 2000 05:52:00:857AMSteve WolfeStart from last shot from yesterday 1001213022.
Change seg 2 title -> 0.8 MA, 4.5 T, diverted
Load/Clean
Coldstart
all matrices respond
14-DEC-2000 05:51:04.42
Dec 14 2000 05:53:52:420AMSteve WolfeEngineering Setup and Run Plan for Thursday, Dec 14

MP#277A Two freq heating and ITB Physics
SL: Bonoli
PO: Wolfe

** Run will start at 07:30 and end at 15:30 ***

ECDC in D2 overnight, ending at least one hour before start of run

Power systems as on 1001213001

Gas Setup:
fill B-top with 6 psi of D2 Hybrid enabled
fill B-side lower with 1 psi of Ar Hybrid enabled
fill B-side upper with 35 psi of D2 Hybrid DISABLED, for ECDC
fill C-side with 30 psi of D2 Hybrid enabled
leave J-bot as is Hybrid DISABLED

Enable the following gate valves: ECE, VUV, DNB

RF Setup: XMTRs 1,2, and 4 should be made ready for operation by 7:00

Plan:

We will continue with the two-frequency heating experiment from where it left
off on Wednesday, and get as far as we can.
Dec 14 2000 07:40:55:030AM1001214001Steve WolfeShot#1: DNB will not fire on this shot. However, I'll leave Gas puff as is at 22msec.
Reduce Ar puff from 50->30msec

plasma, h-mode starts at 0.9sec, EDA.
HIREX Jr signal looks very low? B-side lower was not enabled.
RF looks clean up to 0.5MW, L-H at <0.4MW.
NL4 is flat, core TS densities rising some; perhaps VH'ish?

Next shot: enable Argon
Dec 14 2000 07:53:33:547AM1001214002Steve WolfeShot#2: No PCS changes; enable Argon
Plasma, h-mode starts at 1.0sec; had an injection at 0.8,
but EDA phase looks good. Good signal on jr this time.
RF ramps to 0.7MW. Any peaking of the density seems to be after the RF.
TRAQ2 data corrupted, I'll have to run EFIT again with PCS data

Next shot: no PCS changes
Dec 14 2000 08:10:45:280AM1001214003Steve WolfeShot#3: No PCS changes, increasing RF power again.
plasma, h-mode starts at .83 but ends at 1.09; RF tripped starting at L-H transition.

Next shot: Move RCUR out to 0.672 from .5sec on, to flatten outer gap.

Dec 14 2000 08:24:31:827AM1001214004Steve WolfeShot#4: Move RCUR out to 0.672 from .5sec on, to flatten outer gap.
plasma, nice long h-mode from .83 to 1.56sec, EDA, Prad falling.
RF to 0.9MW, with a few trips. OUter gap is pretty flat at ~0.75cm

next shot: No PCS changes
Dec 14 2000 08:46:19:730AM1001214005Steve WolfeShot#5: No PCS changes, raise power.
plasma, h-mode from .72 to .94, then dithering after RF trip at .74, retries.
Startup had a bounce outside, recovered.
Data system hung; Josh not in yet.

Next shot: DNB will open; no pcs change, since curent rise is getting too fast anyway.
Dec 14 2000 09:51:16:547AM1001214006Steve WolfeShot#6: DNB will open;
no pcs change, since curent rise is getting too fast anyway.
An hour delay for data system hang.

fizzle. runs outside, didn't make it. p0=.066, just like previous.

next shot: raise pg4 by 3msec

Dec 14 2000 10:08:53:437AM1001214007Steve WolfeShot#7: raise pg4 by 3msec to 25msec
plasma, h-modes, rf faults
slight hesitation, still moving out though not as much
bd a little later this time? p0=.077

next shot: Increase rcur offset in seg1 from 5500 to 6500.
Dec 14 2000 10:24:23:013AM1001214008Steve WolfeShot#8: Increase rcur offset in seg1 from 5500 to 6500.
Try again for higher rf power, changing waveform

plasma, hmodes, rf still faulting at high power (900kW), not at LH transition.
less hesitation, doesn't move out as hard.

next shot: try again
Dec 14 2000 10:44:27:997AM1001214009Steve WolfeShot#9:No PCS changes; try again
plasma, hmodes. disrupted in rampdown at 1.75sec.
fast current rise, still moving out, but no hesitation; leave it alone.

Same RF behavior, maybe a little worse.

Next shot: Wukitch installing attenuators in power room.
Dec 14 2000 11:01:25:950AM1001214010Steve WolfeShot#10:No PCS changes; try again
plasma, full length, 2 h-modes, second (>1.1s)is strong eda.
RF ramps to 1.05MW, with some faulting; seems better.
p0 up to .085mTorr, outward motion small if any. smooth current rise.

next shot: try for higher power.
Dec 14 2000 11:19:06:780AM1001214011Steve WolfeShot#11:No PCS changes; try for higher power.
plasma, rf faults at LH transition, retries to 1.1sec, dithering thereafter

next shot: increase outer gap by 2mm
Dec 14 2000 11:39:28:937AM1001214012Steve WolfeShot#12: increase outer gap by 2mm (rcur to .671)
plasma, hmode to 1.2sec, then dithers. 0.9MW and faulting.

next shot: move on, turn on D&E from 0.5sec, J-port late.
Dec 14 2000 11:57:11:297AM1001214013Steve WolfeShot#13: move on, turn on D&E (80MHz) from 0.5sec, J-port(70MHz) late.
plasma, h-modes, 2nd one is good eda.
NO Peaking apparent on this shot (based on TS ne0)
1MW total from D&E.

next shot: raise power.
Dec 14 2000 12:16:31:107PM1001214014Steve WolfeShot#14: raise power.
plasma, long eda h-mode, starting at .95 or so
This one looks like it may peak up density, then heat the center
(based on nl4, TS ne0, and neutrons)

next shot: raise the power again.
Dec 14 2000 12:36:52:827PM1001214015Steve WolfeShot#15: raise the power again.
h-mode still delayed, a little earlier, less eda until J comes on.
RF looks good at 2MW from D&E, .7 from J.
Weak peaking if any, but J does double the neutron rate.

next shot: repeat
Dec 14 2000 12:48:51:750PM1001214016Steve WolfeShot#16:repeat
plasma, h-mode at 0.91sec (same as 15)
D&E clean, J has some faulting.

next shot: 4.4T
Dec 14 2000 01:15:43:170PM1001214017Steve WolfeShot#17: 4.4T (121 kA)
plasma, later H-mode, 1 D-port fault, gives an H-L.
less eda'ish, lower neutrons. More peaking,ECE cutoff.
Big MHD at 1.2sec, seen on bolos and xray (and ECE before it gets completely cutoff)

next shot: Extend tf to 1.5sec (was 1.4)
Dec 14 2000 01:44:27:030PM1001214018Steve WolfeShot#18: Extend tf to 1.5sec (was 1.4)
some delay for data system hang (JAS at lunch); it was the video storage; fixed.

plasma, 2 h-modes, almost identical to 17.
Doesn't look like it peaks this time
no MHD this time either.
Dec 14 2000 02:05:18:200PM1001214019Steve WolfeShot#19: Raise the D&E power.
plasma, H-mode at .9, H-L at 1.05 (d faults and tays off), L-H at 1.117
No peaking.
bd is getting a little late (6.8msec).

next shot: Beam to 0.3, RF to 0.5sec (D&E)
Dec 14 2000 02:20:21:280PM1001214020Steve WolfeShot#20: Beam to 0.3, RF to 0.5sec (D&E)

plasma, h-modes at .58, disrupted at 1sec.
BUSLV CAMAC failed; device not triggered. Store them manually.
p0 went up to .095mTorr, due to DNB change?

next shot: drop pg4 to 22msec; drop power back to 2MW
Dec 14 2000 02:38:36:340PM1001214021Steve WolfeShot#21: drop pg4 to 22msec; drop DE power back to 2MW
plasma, H-mode at .96 sec, elm free, then some faulting; eda during J-port
p0=.085mTOrr, bd at 5.9msec, smooth current rise.

next shot: 4.6T
Dec 14 2000 02:55:08:373PM1001214022Steve WolfeShot#22: 4.6T (127KA)
H-mode at 1.01sec . What is the matter.
ELM free, neuts = 5e12, then eda with <2e12.
Lose D at first H-L transition.

next shot: turn off DNB.
Dec 14 2000 03:13:01:340PM1001214023Steve WolfeShot#23:turn off DNB. No change, h-mode at 1.05sec.

next shot: load seg 2 from 1001213016
Dec 14 2000 03:30:45:560PM1001214024Steve WolfeShot#24: load seg 2 from 1001213016; RF like that shot, except for J-port left on at 1.3sec
H-mode at .93sec, i.e. late again. FOrst h-mode is ELM-free.
No sign of peaking.

Engineering Operator Comments
ShotTimeTypeStatusComment
107:32:09:967AMPlasmaOk
207:46:57:233AMPlasmaOk
308:01:50:640AMPlasmaOk
408:17:37:187AMPlasmaOk
508:33:48:107AMPlasmaOk
609:46:17:967AMPlasmaOk
709:59:29:827AMPlasmaOk
810:19:15:450AMPlasmaOk
910:36:42:513AMPlasmaOk
1010:52:18:230AMPlasmaOk
1111:11:21:387AMPlasmaOk
1211:30:22:357AMPlasmaOk
1311:47:53:107AMPlasmaOk
1412:05:41:420PMPlasmaOk
1512:25:45:217PMPlasmaOk
1612:40:26:797PMPlasmaOk
1701:02:26:590PMPlasmaOk
1801:33:58:297PMPlasmaOk
1901:53:29:733PMPlasmaOk
2002:09:28:077PMPlasmaOk
2102:29:12:467PMPlasmaOk
2202:48:18:780PMPlasmaOk
2303:09:40:437PMPlasmaOk
2403:23:15:670PMPlasmaOk