| Session leader(s): | Steve Wukitch |
| Physics operator(s): | Robert Granetz,Earl Marmar |
| Engineering operator(s): | Bill Parkin,Ed Fitzgerald |
| Engineering Operator Run Comment |
| MP215: J antenna conditioning PO-Granetz SL-Wukitch EO-Fitzgerald,Parki |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:26:350PM |
| Author: To Be Determined |
| ---------------------------------------------------------------------------- RF Setup: Transmitters 1, 2, 3, and 4 should be in run-on by 08:00. ------------------------------------------------------------------------------- Run Plan: MP 215 : J antenna conditioning The first shot will be an OH test under PLC control to confirm that the magnetics system is working properly after yesterday's maintenance. For plasma operation, load 1010606016 (1 MA, 5.4 T). Between-shot ECDC will probably be used to reduce the H/D ratio further. Helium will be puffed for DNB/CXRS. We may also try to do some more shaping changes for the ASDEX comparison MP. This will primarily involve increasing CLEARIN (keeping outer gap constant), and RXL (keeping strike point below the nose). 1. Increase J-port pulse duration and power 2. Verify calibration factors for J4. ------------------------------------------------------------------------------- - 001 OH test 002 Demand: Ip=1MA, nl04=0.8x10^20 D: 0.5 MW [.85-1.5s] E: 0.5 MW [.85-1.5s] J3: 0.12 MW [.63-.645s] J4: 0.13 MW [.63-.645s] Result: good plasma Ip=1 MA, nl04 to 1.0x10^20 D: 0.7 MW [.85-1.5s] E: 0.7 MW [.85-1.5s] J3: 0.10 MW [.63-.645s] J4: 0.10 MW [.63-.645s] retuned J4 for shot 003 003 Demand: Ip=1MA, nl04=0.8x10^20 D: 0.9 MW [.85-1.5s] E: 0.9 MW [.85-1.5s] J3: 0.175 MW [.63-.665s] J4: 0.175 MW [.63-.665s] Result: good plasma Ip=1 MA, nl04 to 1.0x10^20 (small H-mode at 1.3 s) D: 0.9 MW [.85-1.5s] E: 0.9 MW [.85-1.5s] J3: faults J4: faults undid previous tune for J4 for shot 004 004 Demand: Ip=1MA, nl04=0.8x10^20 D: 1.1 MW [.85-1.5s] E: 1.1 MW [.85-1.5s] J3: 0.175 MW [.63-.665s] J4: 0.175 MW [.63-.665s] Result: good plasma Ip=1 MA, nl04 to 1.0x10^20 (small H-mode at 1.2 s) D: 1.1 MW [.85-1.5s] fault at 1.36 E: 1.1 MW [.85-1.5s] faults at 1.22 (phase balance),1.24,1.26 J#: 0.2 MW J4: 0.2 MW E went into supersafe mode after phase balance fault after shot 4 Trans #2 had crowbars fire there were faults on HVPS AC, HVPS DC, and screens 005 Demand: Ip=1MA, nl04=0.8x10^20 D: 1.2 MW [.85-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.225 MW [.63-.665s] J4: 0.225 MW [.63-.665s] Result: good plasma Ip=1 MA, nl04 to 1.0x10^20 (small H-mode at 1.2 s) D: 1.2 MW, but faults on ramp (.86,.88,.91,.93,.96, .98), then faults after 1.38s E: 1.2 MW, but faults at 1.23 (phase balance due to H-mode),1.24,1.26 J3: off because of J4 faults J4: faults 006 Demand: Ip=1MA, nl04=0.8x10^20 D: 1.2 MW [.85-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.58-.71s] J4: 0.4 MW [.58-.71s] Result: good plasma Ip=1 MA, nl04 to 1.0x10^20 (small H-mode at 1.2 s) D: 1.2 MW but faults on ramp (.86,.88,.91,.93,.96, .98), then faults after 1.38s E: 1.2 MW, but faults at 1.23 (phase balance due to H-mode),1.24,1.32 J3: 0.4 MW fault at .66s J4: 0.4 MW fault at .66s during shot Trans #1 had a phase balance fault after shot 006 on trans #3 we are disabling the soft-start relay on the driver screen, since it is intermittant. In addition, we removed the PLC check on the HV during pulse for #3 and #4. 007 request: D: 1.2 MW [.85-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-.85 s] J4: 0.4 MW [.6-.85 s] result: plasma D: failed - ph balance fault on PS E: 1.2 MW [.85-1.5s] J3: failed multiple faults J4: failed multiple faults Noticed FMIT#3 driver screen voltage is lower during a pulse compared to test pulses. 008 D: 1.2 MW [.85-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-.85 s] J4: 0.4 MW [.6-.85 s] result: plasma D: failed - ph balance fault on PS E: 1.2 MW [.85-1.5s] J3: failed multiple faults J4: failed multiple faults 009 D: 0.8 MW [.85-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-.85 s] J4: 0.4 MW [.6-.85 s] result: plasma D: failed - ph balance fault on PS E: 1.2 MW [.85-1.5s] J3: failed multiple faults J4: failed multiple faults offset D and E turn-on 010 D: 0.8 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-.85 s] J4: 0.4 MW [.6-.85 s] result: plasma D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: failed multiple faults J4: failed multiple faults 011 D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-.85 s] J4: 0.4 MW [.6-.85 s] result: plasma D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-.85 s] wahoo they ran J4: 0.4 MW [.6-.85 s] 012 D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-1.4 s] J4: 0.4 MW [.6-1.4 s] result: plasma D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-1.4 s] multiple faults J4: 0.4 MW [.6-1.4 s] multiple faults 013 D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] J4: 0.75 MW [.6-1.4 s] result: plasma D: 1.0 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-1.4 s] multiple faults J4: 0.4 MW [.6-1.4 s] multiple faults phase is set to 20 deg and the measured phase is 0 corresponding to 0,pi,0,pi 014 D: 1.2 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] J4: 0.75 MW [.6-1.4 s] result: plasma D: 1.3 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.4 MW [.6-1.4 s] multiple faults J4: 0.4 MW [.6-1.4 s] multiple faults 015 D: 1.2 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] J4: 0.75 MW [.6-1.4 s] - decreased the attenuation on the phase feedback - increased stub length result: plasma D: 1.3 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] multiple faults J4: 0.75 MW [.6-1.4 s] multiple faults 016 D: 1.2 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] J4: 0.75 MW [.6-1.4 s] - changed #4 tune and ramped the power result: plasma - early disruption D: 0. MW [.81-1.5s] E: 0. MW [.85-1.5s] J3: 0.8 MW [.6-1.4 s] multiple faults J4: 0.8 MW [.6-1.4 s] multiple faults 017 D: 1.2 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] J4: 0.75 MW [.6-1.4 s] result: plasma D: 0 MW [.81-1.5s] E: 0 MW [.85-1.5s] J3: 0.8 MW [.6-1.4 s] multiple faults J4: 0. MW [.6-1.4 s] no power screen rollback signal kept #4 from firing - fried by previous tube arc 018 D: 1.2 MW [.81-1.5s] E: 1.2 MW [.85-1.5s] J3: 0.75 MW [.6-1.4 s] J4: 0.75 MW [.6-1.4 s] result: plasma D: 0 MW [.81-1.5s] E: 0 MW [.85-1.5s] J3: 0.8 MW [.6-1.4 s] multiple faults J4: 0.8 MW [.6-1.4 s] screen rollback signal kept #4 from firing - fried by previous tube arc 019 data system problem 020 data system meltdown Summary The maximum injected power from J-port was ~1.7 MW for ~50 msec and was limited by antenna conditioning time, ie the tuning was the pacing item. The maximum power from all the antennas was ~4 MW but these were ~1 msec. The maximum sustained power from all antennas was 3.7 MW, see shot 012. The difficulties today were numerous. FMIT#1 has a power supply phase balance fault early in the day. D-port also appeared to have numerous phase balance faults from the strap nearest E-port and had to be started before E-port or it would not run. FMIT#3 had HV ready failures during at least 2 discharges (control ladder problem). FMIT#4 had a tube arc that fried the screen rollback circuit resulting a missed shot lat in the day. FMIT#4 also proved to be the most difficult to match. The proper match was extremely difficult to find because too low (<200 kW) of a power resulted in what appears to be multipactoring and too high simply faulted for the entire discharge. However, 018 was very encouraging because we were able to verify the calibration factors for J4. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:13:190PM |
| Author: To Be Determined |
| Physics operator summary for run 1010608 (Friday): MP 215 : J-antenna RF conditioning Session leader: Wukitch/Boivin Physics operator: E. Marmar (R. Granetz for beginning of day) Engineer: G. Dekow/B. Cochran Summary: Scorecard: 17 plasmas 0 fizzles 0 duds 1 test 1 aborted and/or screwed up by computer problems ---------- 20 total ------------------------------------------------------------------------------- Engineering setup: ECDC in D2 overnight prior to run. ******************************************************************************* * * * The first shot will be an OH test under PLC control to confirm that the * * magnetics system is working properly after yesterday's maintenance. * * * ******************************************************************************* Then setup power systems as on 1010606016. Be prepared for ECDC in D2 between shots (using B-top valve). Gas setup: fill B-top with 6 psi of D2 Hybrid enabled (PG4) fill B-side lower with 1 psi of Ar Hybrid enabled (PG1) fill B-side upper with 6 psi of He Hybrid enabled (PG2) fill C-side with 30 psi of D2 Hybrid enabled (PG3) fill J-bottom with nothing Hybrid DISABLED (PG5) Enable the following gate valves: ECE, DNB, VUV Run starts at 09:00 and ends at 17:00. ------------------------------------------------------------------------------- RF Setup: Transmitters 1, 2, 3, and 4 should be in run-on by 08:00. ------------------------------------------------------------------------------- Run Plan: MP 215 : J antenna conditioning The first shot will be an OH test under PLC control to confirm that the magnetics system is working properly after yesterday's maintenance. For plasma operation, load 1010606016 (1 MA, 5.4 T). Between-shot ECDC will probably be used to reduce the H/D ratio further. Helium will be puffed for DNB/CXRS. We may also try to do some more shaping changes for the ASDEX comparison MP. This will primarily involve increasing CLEARIN (keeping outer gap constant), and RXL (keeping strike point below the nose). Results: The machine ran well. The DNB was down with a power supply problem. The RF made good progress today, including a few shots with all 4 transmitters running simultaneously into plasma (e.g. shot 12). Efforts were made to add as much D_2 as possible, without increasing the density, by puffing through the middle of the shot (20 V preprogram on PG3, with feedback turned off, and then 100 V during rampdown). ECDC was also run in deuterium before every shot. H/D levels fell slowly through the day; they still rise during RF, but only up to about 0.4 by the end of the run. The last shot of the day was lost to a data system problem, probably caused by a CAMAC highway problem. ------------------------------------------------------------------------------- Overnight ECDC in D2 was done. Hybrid coldstart done; no errors found ------------------------------------------------------------------------------- DNB has a fault of unknown origin which prevents operation for the moment. Shot 01 -- Test; OH1 and OH2's under PLC control. This is to confirm that the magnetics is working okay after yesterday's maintenance work. All OK. Next shot: go for plasma. Shot 02 -- Plasma; hards early. H/D 0.15 rising to 0.45; Marmar taking over as physop. Shot 03 -- Discharge clean 10 minutes before shot 3; add 2 msec to prefill puff (now 26 msec); plasma; hards are gone; possible H-mode transition at 1.3 seconds; much nicer startup. Shot 04 -- Discharge clean 10 minutes before shot 4; add a bit of voltage to PG3 preprog in seg 2 (20 v); nl_04 still set to 0.8e20 plasma; H/D 0.16 to 0.53; small neutron rate increase during J-port (400 kW). Shot 05 -- Discharge clean 10 minutes before shot 5; add a D_2 puff after 1.5 seconds; plasma; H/D 0.16 to 0.5, then back down to 0.35 after 1.5 seconds. Shot 06 -- Discharge clean 10 minutes before shot 6; no PCS changes plasma; H/D 0.16 to 0.45, then down to 0.31 after 1.5 seconds; J-port to 0.8 MW; definite heating (neutron rate). Shot 07 -- Discharge clean 21 minutes before shot 7; turn off nl04 feedback at 0.9 seconds; PG3 to 20 Volt from 0.9 to 1.5, then up to 95 V; plasma; H/D 0.16 to 0.40, then down to 0.25. Shot 08 -- Discharge clean 10 minutes before shot 8; PG3 to 120 V after 1.5 s; plasma; H/D 0.13 to 0.40, then down to 0.23; traq1 magnetics data corrupted. EFIT did not run. Shot 09 -- Discharge clean 16 minutes before shot 9; no PCS changes; plasma; H/D 0.13 to 0.35, then down to 0.25. Shot 10 -- Discharge clean 10 minutes before shot 10; turn end of pulse gas puff off at 1.69 seconds in an attempt to keep the McPherson happier; plasma; H/D 0.15 to 0.44 then down to 0.26. Shot 11 -- Discharge clean 10 minutes before shot 11; no PCS changes; plasma; disrupt at 1.22 s; H/D 0.14 to .38; J ran up to 0.8 MW. Shot 12 -- Discharge clean 10 minutes before shot 12; reduce prefill puff by 2 msec; plasma; H/D 0.16 to 0.53 then down to 0.29; total RF up to 3.7 MW for a short time. Shot 13 -- Discharge clean 10 minutes before shot 13; no PCS changes; plasma; H/D 0.16 to 0.48 then down to 0.33; Shot 14 -- Discharge clean 10 minutes before shot 14; no PCS changes; plasma; disrupt at 1.05 seconds; H/D 0.14 to 0.33. Shot 15 -- Discharge clean 10 minutes before shot 15; reduce prepuff by 1 msec; plasma; H/D 0.17 to 0.40, then down to 0.23 Shot 16 -- Discharge clean 10 minutes before shot 16; increase prepuff by 1 msec; plasma; disrupt at 0.68 s; Shot 17 -- Discharge clean 10 minutes before shot 17; decrease prepuff by 1 msec; plasma; H/D 0.13 to 0.40 then down to 0.26. Shot 18 -- Discharge clean 10 minutes before shot 18; no PCS changes; plasma; H/D 0.13 to 0.39 then down to 0.23. Shot 19 -- Discharge clean 10 minutes before shot 19; no PCS changes; data system problem; no power shot Shot 20 -- No ECDC after no power shot 19; no PCS changes; same problem; looks a camac highway meltdown; no power shot From: RHONE::MARMAR Date: 8-JUN-2001 17:29:29 Subj: Physics Operator Run Summary 1010608 Physics operator summary for run 1010608 (Friday): MP 215 : J-antenna RF conditioning Session leader: Wukitch/Boivin Physics operator: E. Marmar (R. Granetz for beginning of day) Engineer: G. Dekow/B. Cochran Summary: Scorecard: 17 plasmas 0 fizzles 0 duds 1 test 2 aborted and/or screwed up by computer problems ---------- 20 total data system cycles ------------------------------------------------------------------------------- Engineering setup: ECDC in D2 overnight prior to run. ******************************************************************************* * * * The first shot will be an OH test under PLC control to confirm that the * * magnetics system is working properly after yesterday's maintenance. * * * ******************************************************************************* Then setup power systems as on 1010606016. Be prepared for ECDC in D2 between shots (using B-top valve). Gas setup: fill B-top with 6 psi of D2 Hybrid enabled (PG4) fill B-side lower with 1 psi of Ar Hybrid enabled (PG1) fill B-side upper with 6 psi of He Hybrid enabled (PG2) fill C-side with 30 psi of D2 Hybrid enabled (PG3) fill J-bottom with nothing Hybrid DISABLED (PG5) Enable the following gate valves: ECE, DNB, VUV Run starts at 09:00 and ends at 17:00. ------------------------------------------------------------------------------- RF Setup: Transmitters 1, 2, 3, and 4 should be in run-on by 08:00. ------------------------------------------------------------------------------- Run Plan: MP 215 : J antenna conditioning The first shot will be an OH test under PLC control to confirm that the magnetics system is working properly after yesterday's maintenance. For plasma operation, load 1010606016 (1 MA, 5.4 T). Between-shot ECDC will probably be used to reduce the H/D ratio further. Helium will be puffed for DNB/CXRS. We may also try to do some more shaping changes for the ASDEX comparison MP. This will primarily involve increasing CLEARIN (keeping outer gap constant), and RXL (keeping strike point below the nose). Results: The machine ran well. The only startup changes made were to the fill pressure, which was increased after the first shot (hard x-rays) and then decreased after disruptions. The only other physop changes were to the gas puffing during the plasmas. There were no shape changes made during the run. The DNB was down with a power supply problem. The RF made good progress today, including a few shots with all 4 transmitters running simultaneously into plasma (e.g. shot 12). Efforts were made to add as much D_2 as possible, without increasing the density, by puffing through the middle of the shot (20 V preprogram on PG3, with feedback turned off, and then 100 V during rampdown). ECDC was also run in deuterium before every shot. H/D levels fell slowly through the day; they still rise during RF, but only up to about 0.4 by the end of the run. The last shot of the day was lost to a data system problem, probably caused by a CAMAC highway problem. ------------------------------------------------------------------------------- Overnight ECDC in D2 was done. Hybrid coldstart done; no errors found ------------------------------------------------------------------------------- Shot 01 -- Test; OH1 and OH2's under PLC control. This is to confirm that the magnetics is working okay after yesterday's maintenance work. All OK. Next shot: go for plasma. Shot 02 -- Plasma; hards early. H/D 0.15 rising to 0.45; Marmar taking over as physop. Shot 03 -- Discharge clean 10 minutes before shot 3; add 2 msec to prefill puff (now 26 msec); plasma; hards are gone; possible H-mode transition at 1.3 seconds; much nicer startup. Shot 04 -- Discharge clean 10 minutes before shot 4; add a bit of voltage to PG3 preprog in seg 2 (20 v); nl_04 still set to 0.8e20 plasma; H/D 0.16 to 0.53; small neutron rate increase during J-port (400 kW). Shot 05 -- Discharge clean 10 minutes before shot 5; add a D_2 puff after 1.5 seconds; plasma; H/D 0.16 to 0.5, then back down to 0.35 after 1.5 seconds. Shot 06 -- Discharge clean 10 minutes before shot 6; no PCS changes plasma; H/D 0.16 to 0.45, then down to 0.31 after 1.5 seconds; J-port to 0.8 MW; definite heating (neutron rate). Shot 07 -- Discharge clean 21 minutes before shot 7; turn off nl04 feedback at 0.9 seconds; PG3 to 20 Volt from 0.9 to 1.5, then up to 95 V; plasma; H/D 0.16 to 0.40, then down to 0.25. Shot 08 -- Discharge clean 10 minutes before shot 8; PG3 to 120 V after 1.5 s; plasma; H/D 0.13 to 0.40, then down to 0.23; traq1 magnetics data corrupted. EFIT did not run. Shot 09 -- Discharge clean 16 minutes before shot 9; no PCS changes; plasma; H/D 0.13 to 0.35, then down to 0.25. Shot 10 -- Discharge clean 10 minutes before shot 10; turn end of pulse gas puff off at 1.69 seconds in an attempt to keep the McPherson happier; plasma; H/D 0.15 to 0.44 then down to 0.26. Shot 11 -- Discharge clean 10 minutes before shot 11; no PCS changes; plasma; disrupt at 1.22 s; H/D 0.14 to .38; J ran up to 0.8 MW. Shot 12 -- Discharge clean 10 minutes before shot 12; reduce prefill puff by 2 msec; plasma; H/D 0.16 to 0.53 then down to 0.29; total RF up to 3.7 MW for a short time. Shot 13 -- Discharge clean 10 minutes before shot 13; no PCS changes; plasma; H/D 0.16 to 0.48 then down to 0.33; Shot 14 -- Discharge clean 10 minutes before shot 14; no PCS changes; plasma; disrupt at 1.05 seconds; H/D 0.14 to 0.33. Shot 15 -- Discharge clean 10 minutes before shot 15; reduce prepuff by 1 msec; plasma; H/D 0.17 to 0.40, then down to 0.23 Shot 16 -- Discharge clean 10 minutes before shot 16; increase prepuff by 1 msec; plasma; disrupt at 0.68 s; Shot 17 -- Discharge clean 10 minutes before shot 17; decrease prepuff by 1 msec; plasma; H/D 0.13 to 0.40 then down to 0.26. Shot 18 -- Discharge clean 10 minutes before shot 18; no PCS changes; plasma; H/D 0.13 to 0.39 then down to 0.23. Shot 19 -- Discharge clean 10 minutes before shot 19; no PCS changes; data system problem; no power shot Shot 20 -- No ECDC after no power shot 19; no PCS changes; same problem; looks a camac highway meltdown; no power shot |
| Session Leader Comments |
| Physics Operator Comments | |||
| Jun 8 2001 08:50:02:107AM | Robert Granetz | ------------------------------------------------------------------------------- Engineering setup: ECDC in D2 overnight prior to run. ******************************************************************************* * * * The first shot will be an OH test under PLC control to confirm that the * * magnetics system is working properly after yesterday's maintenance. * * * ******************************************************************************* Then setup power systems as on 1010606016. Be prepared for ECDC in D2 between shots (using B-top valve). Gas setup: fill B-top with 6 psi of D2 Hybrid enabled (PG4) fill B-side lower with 1 psi of Ar Hybrid enabled (PG1) fill B-side upper with 6 psi of He Hybrid enabled (PG2) fill C-side with 30 psi of D2 Hybrid enabled (PG3) fill J-bottom with nothing Hybrid DISABLED (PG5) Enable the following gate valves: ECE, DNB, VUV Run starts at 09:00 and ends at 17:00. ------------------------------------------------------------------------------- RF Setup: Transmitters 1, 2, 3, and 4 should be in run-on by 08:00. ------------------------------------------------------------------------------- Run Plan: MP 215 : J antenna conditioning The first shot will be an OH test under PLC control to confirm that the magnetics system is working properly after yesterday's maintenance. For plasma operation, load 1010606016 (1 MA, 5.4 T). Between-shot ECDC will probably be used to reduce the H/D ratio further. Helium will be puffed for DNB/CXRS. We may also try to do some more shaping changes for the ASDEX comparison MP. This will primarily involve increasing CLEARIN (keeping outer gap constant), and RXL (keeping strike point below the nose). ------------------------------------------------------------------------------- | |
| Jun 8 2001 08:50:13:480AM | Robert Granetz | ------------------------------------------------------------------------------- Overnight ECDC in D2 was done. Hybrid coldstart done; no errors found ------------------------------------------------------------------------------- | |
| Jun 8 2001 09:15:27:253AM | 1010608001 | Robert Granetz | DNB has a fault of unknown origin which prevents operation for the moment. Shot 01 -- Test; OH1 and OH2's under PLC control. This is to confirm that the magnetics is working okay after yesterday's maintenance work. All OK. Next shot: go for plasma. |
| Jun 8 2001 09:47:43:473AM | 1010608002 | Earl Marmar | Shot 02 -- Plasma; hards early. H/D 0.15 rising to 0.45; Marmar taking over as physop. |
| Jun 8 2001 09:56:38:770AM | 1010608003 | Earl Marmar | Shot 03 -- Discharge clean 10 minutes before shot 3; add 2 msec to prefill puff (now 26 msec); plasma; hards are gone; possible H-mode transition at 1.3 seconds; much nicer startup. |
| Jun 8 2001 10:28:23:490AM | 1010608004 | Earl Marmar | Shot 04 -- Discharge clean 10 minutes before shot 4; add a bit of voltage to PG3 preprog in seg 2 (20 v); nl_04 still set to 0.8e20 plasma; H/D 0.16 to 0.53; small neutron rate increase during J-port (400 kW). |
| Jun 8 2001 11:06:48:020AM | 1010608005 | Earl Marmar | Shot 05 -- Discharge clean 10 minutes before shot 5; add a D_2 puff after 1.5 seconds; H/D 0.16 to 0.5, then back down to 0.35 after 1.5 seconds. |
| Jun 8 2001 11:18:51:927AM | 1010608006 | Earl Marmar | Shot 06 -- Discharge clean 10 minutes before shot 6; no PCS changes plasma; H/D 0.16 to 0.45, then down to 0.31 after 1.5 seconds; J-port to 0.8 MW; definite heating (neutron rate). |
| Jun 8 2001 11:46:40:363AM | 1010608007 | Earl Marmar | Shot 07 -- Discharge clean 21 minutes before shot 7; turn off nl04 feedback at 0.9 seconds; PG3 to 20 Volt from 0.9 to 1.5, then up to 95 V; plasma; H/D 0.16 to 0.40, then down to 0.25. |
| Jun 8 2001 12:34:44:467PM | 1010608008 | Earl Marmar | Shot 08 -- Discharge clean 10 minutes before shot 8; PG3 to 120 V after 1.5 s; plasma; H/D 0.13 to 0.40, then down to 0.23; traq1 magnetics data corrupted. EFIT did not run. |
| Jun 8 2001 12:58:32:427PM | 1010608009 | Earl Marmar | Shot 09 -- Discharge clean 16 minutes before shot 9; no PCS changes; plasma; H/D 0.13 to 0.35, then down to 0.25. |
| Jun 8 2001 01:32:59:400PM | 1010608010 | Earl Marmar | Shot 10 -- Discharge clean 10 minutes before shot 10; turn end of pulse gas puff off at 1.69 seconds in an attempt to keep the McPherson happier; plasma; H/D 0.15 to 0.44 then down to 0.26. |
| Jun 8 2001 01:33:13:290PM | 1010608011 | Earl Marmar | Shot 11 -- Discharge clean 10 minutes before shot 11; no PCS changes; plasma; disrupt at 1.22 s; H/D 0.14 to .38; J ran up to 0.8 MW. |
| Jun 8 2001 02:28:12:593PM | 1010608012 | Earl Marmar | Shot 12 -- Discharge clean 10 minutes before shot 12; reduce prefill puff by 2 msec; plasma; H/D 0.16 to 0.53 then down to 0.29; total RF up to 3.7 MW for a short time. |
| Jun 8 2001 02:48:34:143PM | 1010608013 | Earl Marmar | Shot 13 -- Discharge clean 10 minutes before shot 13; no PCS changes; plasma; H/D 0.16 to 0.48 then down to 0.33; |
| Jun 8 2001 02:48:46:563PM | 1010608014 | Earl Marmar | Shot 14 -- Discharge clean 10 minutes before shot 14; no PCS changes; plasma; disrupt at 1.05 seconds; H/D 0.14 to 0.33. |
| Jun 8 2001 03:44:02:057PM | 1010608015 | Earl Marmar | Shot 15 -- Discharge clean 10 minutes before shot 15; reduce prepuff by 1 msec; plasma; H/D 0.17 to 0.40, then down to 0.23 |
| Jun 8 2001 03:44:33:743PM | 1010608016 | Earl Marmar | Shot 16 -- Discharge clean 10 minutes before shot 16; increase prepuff by 1 msec; plasma; disrupt at 0.68 s |
| Jun 8 2001 04:26:20:010PM | 1010608017 | Earl Marmar | Shot 17 -- Discharge clean 10 minutes before shot 17; decrease prepuff by 1 msec; plasma; H/D 0.13 to 0.40 then down to 0.26. |
| Jun 8 2001 04:47:01:200PM | 1010608018 | Earl Marmar | Shot 18 -- Discharge clean 10 minutes before shot 18; no PCS changes; plasma; H/D 0.13 to 0.39 then down to 0.23. |
| Jun 8 2001 05:07:29:793PM | 1010608019 | Earl Marmar | Shot 19 -- Discharge clean 10 minutes before shot 19; no PCS changes; data system problem; no power shot |
| Jun 8 2001 05:18:13:887PM | 1010608020 | Earl Marmar | shot 20 -- No ECDC after no power shot 19; no PCS changes; same problem; looks a camac highway meltdown; no power shot |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:08:32:617AM | Test | Ok | |
| 2 | 09:22:22:793AM | Plasma | Ok | |
| 3 | 09:48:05:553AM | Plasma | Ok | |
| 4 | 10:13:32:360AM | Plasma | Ok | |
| 5 | 10:43:31:793AM | Plasma | Ok | |
| 6 | 11:06:59:377AM | Plasma | Ok | |
| 7 | 11:38:30:190AM | Plasma | Ok | |
| 8 | 12:02:34:043PM | Plasma | Ok | |
| 9 | 12:36:31:140PM | Plasma | Ok | |
| 10 | 01:01:09:053PM | Plasma | Ok | |
| 11 | 01:25:10:420PM | Plasma | Ok | |
| 12 | 01:49:25:720PM | Plasma | Ok | |
| 13 | 02:14:52:217PM | Plasma | Ok | |
| 14 | 02:39:50:690PM | Plasma | Ok | |
| 15 | 03:06:11:527PM | Plasma | Ok | |
| 16 | 03:32:44:837PM | Plasma | Ok | |
| 17 | 04:08:00:123PM | Plasma | Ok | |
| 18 | 04:34:50:100PM | Test | Bad | |
| 19 | 05:02:17:753PM | Test | Ok | no power shot |
| 20 | 05:15:57:103PM | Test | Ok | No power shot |