Alcator C-Mod Run 1010612 Information

Back to runs

Miniproposals
Miniproposal:215
Date Filed: 1/5/1999
Title:J-port RF System Commissioning
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-14)
Session Leader:Rejean Boivin (shots 1-14)

Operators
Session leader(s):Steve Wukitch,Rejean Boivin
Physics operator(s):Joseph Snipes
Engineering operator(s): Unknown

Engineering Operator Run Comment
Boronization Recovery/MP215 Jport RF Cond; SL: Wukitch/Boivin; PO: Snipe

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:26:367PM
Author: To Be Determined
Run Plan for Tuesday, June 12, 2001

Boronization Recovery
MP215 Jport RF Conditioning

SL: Wukitch/Boivin
PO: Snipes

Engineering setup:

Boronization overnight prior to run.

XMTR 1 through 4 should be in run-on by 8:00 AM.

Run starts at 9:00AM
Power systems as on 1010608018.

Gas setup:
fill B-top with 6 psi of D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi of Ar Hybrid enabled (PG1)
fill B-side upper with 6 psi of He Hybrid DISABLED (PG2) **
fill C-side with 30 psi of D2 Hybrid enabled (PG3)
fill J-bottom with 6 psi of He Hybrid DISABLED (PG5) **

Enable the following gate valves: ECE, DNB, and VUV.

Run plan:

The run will be boronization recovery followed by RF conditioning, MP215.
If it can be accommodated without problems to the other activities, we will
attempt to finish the shape development for MP287, ASDEX comparison.

Changes made to RF during the abbreviated maintenance day:

1. J-port phase balance enable had its offset adjusted (offset comes
from the fiber optic transmitters)

2. Notch filters were installed in D-port I-probes to eliminate cross
talk from E-port.

3. D-port water system was repaired but the repair failed. D-port is
off the air till further notice.


001
Ip~1.0 MA, nl04~0.8, BT~5.4

E: 0.8 [.8,1.5] sec
J3:0.8 [0.6,1.5] sec
J4:0.8 [0.5,1.5] sec

result: plasma, late H-mode

E: 0.8 with 3 faults
J3: 0.8 multitude of faults
J4: 0.8 multitude of faults

002
Ip~1.0 MA, nl04~0.8, BT~5.4

E: 1.0 [.8,1.5] sec
J3:0.8 [0.6,1.5] sec
J4:0.8 [0.5,1.5] sec

result: plasma, late H-mode

E: 1.0 with 3 faults
J3: 0.8 multitude of faults
J4: 0.8 multitude of faults

screen xbar fired on #3
next shot: change phase by +90deg (20 to 110)

003
Ip~1.0 MA, nl04~0.8, BT~5.4

E: 1.0 [.8,1.5] sec
J3:0.8 [0.6,1.5] sec
J4:0.8 [0.5,1.5] sec

result: plasma, early disruption

E: 1.0 MW
J3: 0.8 multitude of faults
J4: 0.8 multitude of faults

004
Ip~1.0 MA, nl04~0.8, BT~5.4

E: 1.2 [.8,1.5] sec
J3:0.8 [0.6,1.5] sec with slow ramp
J4:0.8 [0.5,1.5] sec with slow rapm

result: plasma, late H-mode

E: 1.2 MW
J3: 0.8 multitude of faults but more data
J4: 0.8 multitude of faults but more data

005

E: 1.0 [.8,1.5] sec
J3:0.8 [0.6,1.5] sec with slower ramp
J4:0.8 [0.5,1.5] sec with slower ramp

result: plasma, late H-mode

E: 1.0 MW
J3: 0.8 multitude of faults but more data
J4: 0.8 multitude of faults but more data

optical monitoring is picking up light from one strap (#4) that
correspond to a fault.

phase is ~0,.7pi,0,.7pi

next shot: change from 110 deg to 140 deg

006 fizzle

007

E: 1.0 [.8,1.5] sec
J3:0.8 [0.6,1.5] sec with slower ramp
J4:0.8 [0.5,1.5] sec with slower ramp

result: plasma, late H-mode

E: 1.0 MW
J3: 0.8 multitude of faults
J4: 0.8 multitude of faults


phase is ~0,.6pi,0,.6pi

next shot: change from 140 deg to 80 deg

008

E: 1.0 [1.2,1.5] sec
J3:0.8 [0.6,1.5] sec with slower ramp
J4:0.8 [0.5,1.5] sec with slower ramp

result: plasma, late H-mode

E: 1.0 MW
J3: 0.8 multitude of faults
J4: 0.8 multitude of faults


phase is ~0,.9pi,0,.9pi

009

E: 1.0 [1.2,1.5] sec
J3:0.4 [0.6,1.5] sec with slower ramp
J4:0.4 [0.5,1.5] sec with slower ramp

result: plasma, late H-mode

E: 0.9 MW
J3: 0.4 better - faults @ .655, 1.12 s
J4: 0.4 faults

010

E: 1.0 [1.2,1.5] sec
J3:0.5 [0.6,1.5] sec with slower ramp
J4:0.5 [0.5,1.5] sec with slower ramp

result: plasma, late H-mode
H/D climbs to 0.11
E: 0.9 MW
J3: 0.5 more faults
J4: 0.5 more faults

J ran in H-mode loading drops to ~12 ohms
repeat with retune on #3

start ECDC between discharges

011

E: 1.0 [1.2,1.5] sec
J3:0.5 [0.6,1.5] sec with slower ramp
J4:0.5 [0.5,1.5] sec with slower ramp

result: plasma, late H-mode
H/D climbs to 0.11
E: 0.9 MW
J3: 0.5 more faults
J4: 0.5 more faults

012 runaway density

013 power test

014

E: 1.0 [1.2,1.5] sec
J3:0.5 [0.6,1.5] sec with slower ramp
J4:0.5 [0.5,1.5] sec with slower ramp

result: plasma

E: 0.9 MW
J3: 0.5 cleaner
J4: 0.5 cleaner

phase is ~[0,pi,pi,0]

Post run vacuum conditioning
J3 J4 J3 J4
[MW] [MW] [kV] [kV]
1586 60 60
1587 80 80 16 J4 faulted
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
phase balance faults have been replaced by DC0 faults
1599
1600
1601

Summary:

E-port antenna conditioned very quickly and J-port was making progress
in reconditioning after boronization. Both antennas had clear
indications of heating. However, it became clear that J-port needed
to be voltage conditioned again; therefore, we decided to switch to
vacuum conditioning. During conditioning, FMIT#4 phase shifter began
breaking down after it reached 25 kV and then began to decrease
suggesting something had become tracked. We will need to disassemble
and inspect before we continue with J-port testing.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:13:207PM
Author: To Be Determined
Run Plan for Tuesday, June 12, 2001

Boronization Recovery
MP215 Jport RF Conditioning

SL: Wukitch/Boivin
PO: Snipes

Engineering setup:

Boronization overnight prior to run.

XMTR 1 through 4 should be in run-on by 8:00 AM.

Run starts at 9:00AM
Power systems as on 1010608018.

Gas setup:
fill B-top with 6 psi of D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi of Ar Hybrid enabled (PG1)
fill B-side upper with 6 psi of He Hybrid DISABLED (PG2) **
fill C-side with 30 psi of D2 Hybrid enabled (PG3)
fill J-bottom with 6 psi of He Hybrid DISABLED (PG5) **

Enable the following gate valves: ECE, DNB, and VUV.

Run plan:

The run will be boronization recovery followed by RF conditioning, MP215.
If it can be accommodated without problems to the other activities, we will
attempt to finish the shape development for MP287, ASDEX comparison.

Summary: The post boronization run was a breeze. The plasmas all went full
length except for shot 6 that fizzled. There was also one test on shot 13.
There were 12 full length plasmas, 1 test, and 1 fizzle.


Shot 1: Copied shot 1010608018. Enabled B-side upper He puff for DNB. Turned
off the gas puff Marmar had put in after 1.5 s and turned the nl04 feedback on
again out to 1.85 s. nl04 request set to 8 x 10^19 m^-2 as before. Ip set to
1 MA as before. Good shot ramps all the way down. RF H-mode 1.3 - 1.5 s.
Shot 2: Good shot. H-mode from 1.2 - 1.6 s.
Shot 3: Repeat. Disrupted at 1.08 s perhaps due to an impurity injection.
Shot 4: Reduced prepuff to 18 ms duration from 24 ms due to the disruption.
Good plasma but with some x rays early.
Shot 5: Good shot.
Shot 6: Fizzle!
Shot 7: Raise EF4 current by 20 A from -1290 to -1270 A. Good plasma.
Shot 8: Good shot.
Shot 9: Repeat with DNB pulse at 1.3 s. Good shot.
Shot 10: Good shot. H-mode from 1.37 sec into rampdown as on several shots
today. H/(H+D) now > 0.1 at the end of the shot. So, we will now do ECDC in
D2 between shots for 10 minutes.
Shot 11: Good shot. H-mode from 1.27 sec to 1.56 sec. H/(H+D) now < 0.09 at
the end of the shot. So, we will continue to do ECDC in D2 between shots for
10 minutes.
Shot 12: Good shot until we lost the interferometer at about 0.86 sec. Still,
it went fine until about 1.78 sec when it disrupted probably because the
density feedback was not working and there was too much gas.
Shot 13: EF2U and L test shot because of a noise spike on their rogowskis on
shot 12 that made them integrate up wrongly. O.K. No problems with the
integrators.
Shot 14: Good shot. H/(H+D) down to 0.06. The ECDC between shots really helps
to keep it down. Stopping the run for RF maintenance.


Session Leader Comments

Physics Operator Comments
Jun 12 2001 08:48:14:297AMJoseph SnipesRun Plan for Tuesday, June 12, 2001

Boronization Recovery
MP215 Jport RF Conditioning

SL: Wukitch/Boivin
PO: Snipes

Engineering setup:

Boronization overnight prior to run.

XMTR 1 through 4 should be in run-on by 8:00 AM.

Run starts at 9:00AM
Power systems as on 1010608018.

Gas setup:
fill B-top with 6 psi of D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi of Ar Hybrid enabled (PG1)
fill B-side upper with 6 psi of He Hybrid DISABLED (PG2) **
fill C-side with 30 psi of D2 Hybrid enabled (PG3)
fill J-bottom with 6 psi of He Hybrid DISABLED (PG5) **

Enable the following gate valves: ECE, DNB, and VUV.

Run plan:

The run will be boronization recovery followed by RF conditioning, MP215.
If it can be accommodated without problems to the other activities, we will
attempt to finish the shape development for MP287, ASDEX comparison.
Jun 12 2001 09:24:14:863AM1010612001Joseph SnipesShot 1: Copied shot 1010608018. Enabled B-side upper He puff for DNB. Turned
off the gas puff Marmar had put in after 1.5 s and turned the nl04 feedback on
again out to 1.85 s. nl04 request set to 8 x 10^19 m^-2 as before. Ip set to
1 MA as before. Good shot ramps all the way down. RF H-mode 1.3 - 1.5 s.
Jun 12 2001 09:47:28:863AM1010612002Joseph SnipesShot 2: Good shot. H-mode from 1.2 - 1.6 s.
Jun 12 2001 10:09:10:873AM1010612003Joseph SnipesShot 3: Repeat. Disrupted at 1.08 s perhaps due to an impurity injection.
Jun 12 2001 11:21:04:507AM1010612004Joseph SnipesShot 4: Reduced prepuff to 18 ms duration from 24 ms due to the disruption.
Good plasma but with some x rays early.
Jun 12 2001 11:21:14:897AM1010612005Joseph SnipesShot 5: Good shot.
Jun 12 2001 11:32:57:007AM1010612006Joseph SnipesShot 6: Fizzle!
Jun 12 2001 11:37:35:033AM1010612007Joseph SnipesShot 7: Raise EF4 current by 20 A from -1290 to -1270 A. Good plasma.
Jun 12 2001 11:57:38:447AM1010612008Joseph SnipesShot 8: Good shot.
Jun 12 2001 12:24:34:097PM1010612009Joseph SnipesShot 9: Repeat with DNB pulse at 1.3 s. Good shot.
Jun 12 2001 12:48:42:383PM1010612010Joseph SnipesShot 10: Good shot. H-mode from 1.37 sec into rampdown as on several shots
today. H/(H+D) now > 0.1 at the end of the shot. So, we will now do ECDC in D2
between shots for 10 minutes.
Jun 12 2001 01:19:31:887PM1010612011Joseph SnipesShot 11: Good shot. H-mode from 1.27 sec to 1.56 sec. H/(H+D) now < 0.09 at
the end of the shot. So, we will continue to do ECDC in D2 between shots for
10 minutes.
Jun 12 2001 01:44:28:220PM1010612012Joseph SnipesShot 12: Good shot until we lost the interferometer at about 0.86 sec. Still,
it went fine until about 1.78 sec when it disrupted probably because the density
feedback was not working and there was too much gas.
Jun 12 2001 02:42:59:737PM1010612013Joseph SnipesShot 13: EF2U and L test shot because of a noise spike on their rogowskis on
shot 12 that made them integrate up wrongly. O.K. No problems with the
integrators.
Jun 12 2001 03:41:29:733PM1010612014Joseph SnipesShot 14: Good shot. H/(H+D) down to 0.06. The ECDC between shots really helps
to keep it down. Stopping the run for RF maintenance.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:14:52:730AMPlasmaOk
209:38:38:043AMPlasmaOk
310:02:10:653AMPlasmaOk
410:21:00:860AMPlasmaOk
510:51:51:723AMPlasmaOk
611:20:43:050AMPlasmaOk
711:36:02:327AMPlasmaOk
811:55:48:443AMPlasmaOk
912:16:51:750PMPlasmaOk
1012:36:38:850PMPlasmaOk
1101:07:00:447PMPlasmaOk
1201:36:18:743PMPlasmaOk
1302:35:20:967PMTestOkEF2L & U PLC Test
1402:51:03:150PMPlasmaOk