| Session leader(s): | Rejean Boivin |
| Physics operator(s): | Earl Marmar |
| Engineering operator(s): | Bill Cochran |
| Engineering Operator Run Comment |
| MP215 J-Port Conditioning. Boivin/Marmar/Cochran |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:26:413PM |
| Author: To Be Determined |
| Run Plan for Tuesday June 19, 2001 1010619 MP215 J-port Conditioning SL: Boivin PO: Marmar Engineering setup: ECDC in D2 overnight Run starts at Noon Power systems as on 1010612014. Gas setup: fill B-top with 6 psi of D2 Hybrid enabled (PG4) fill B-side lower with 1 psi of Ar Hybrid enabled (PG1) fill B-side upper with 30 psi of D2 Hybrid DISABLED (PG2) fill C-side with 30 psi of D2 Hybrid enabled (PG3) fill J-bottom with 30 psi of He Hybrid DISABLED (PG5) Enable the following gate valves: ECE, DNB, and VUV. Open the Z-bolo shutter for plasma shots (closed during ECDC). Be set up for between-shot ECDC. Run plan: The goal of the run is to continue bringing J-port into full operation. Vacuum testing and conditioning post PS#4 repair J3 J4 [kW] [kW] 1626 100 100 what? 1627 100 #3 into dummy load 1628 100 #3 into dummy load 1629 100 100 #3 into dummy load 1630 100 looking for arcs in #4 1631-43 looking for arcs in #4 breaking down periodically in phase shifter #4 1644 100 150 short period with both are on separate #3 and #4 [kV] [kV] 1645 120 150 24 32 1646 130 150 25 32 1647 1648 1649 170 170 1650 short overlap 1651 1652 1653 long overlap Plasma operation 001 dud 002 dud 003 dud 004 dud 005 fizzle 009 D: [0.87,1.5] 0.75 MW E: [0.91,1.5] 0.75 MW J: [0.6,1.3] 0.6 MW result: plasma late H-mode D: [0.87,1.5] 10 retries and off E: [0.91,1.5] 0.75 MW J: [0.6,1.3] 0.6 MW retries and off 010 D: [0.87,1.5] 0.75 MW E: [0.91,1.5] 0.75 MW J: [0.6,1.3] 0.6 MW result: plasma late H-mode D: [0.87,1.5] 10 retries and off E: [0.91,1.5] 0.75 MW J: [0.6,1.3] 0.6 MW better 011 D: [0.87,1.5] 0.75 MW E: [0.91,1.5] 0.75 MW J: [0.6,1.3] 1.0 MW result: plasma late H-mode D: [0.87,1.5] 10 retries and off E: [0.91,1.5] 0.75 MW J: [0.6,1.3] 1.0 MW better 012 013 014 D: [0.75,1.5] 0.6 MW E: [1.2,1.5] 0.75 MW J: [0.5,1.5] 1.6 MW result: plasma late H-mode D: [0.87,1.5] 10 retries and off E: [1.2,1.5] 0.75 MW J: [.5,1.5] 1.5 MW multiple faults Summary In vacuum, we had a number of arcs localized to FMIT#4 phase shifter that appeared to cleanup. The antenna was conditioned to 32 kV prior to the run. J-port power was increased to 1.5 MW into H-mode but the still has numerous faults. D-port was completely unreliable in stark contrast its last operation (1010608). |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:13:410PM |
| Author: To Be Determined |
| Physop run summary 1010619 Run Plan for Tuesday June 19, 2001 1010619 MP215 J-port Conditioning SL: Boivin PO: Marmar Engineering setup: ECDC in D2 overnight Run starts at Noon Power systems as on 1010612014. Gas setup: fill B-top with 6 psi of D2 Hybrid enabled (PG4) fill B-side lower with 1 psi of Ar Hybrid enabled (PG1) fill B-side upper with 30 psi of D2 Hybrid DISABLED (PG2) fill C-side with 30 psi of D2 Hybrid enabled (PG3) fill J-bottom with 30 psi of He Hybrid DISABLED (PG5) Enable the following gate valves: ECE, DNB, and VUV. Open the Z-bolo shutter for plasma shots (closed during ECDC). Be set up for between-shot ECDC. Run plan: The goal of the run is to continue bringing J-port into full operation. Summary: This was a tough run from the physop point of view. We started at about 1:00 pm. J-port had vacuum conditioned in the morning. The run started with 4 duds followed by 4 fizzles. Then we got 3 plasmas, a fizzle, a dud and finally a plasma. All field and gas changes were small. A leak started to open up around 2:30 pm, and by the end of the run, mass 28 was at 1.2e-7 on the RGA. After the run, it was determined that parts of F-port were iced up. The RF did run on the 4 plasmas. See the logbook for details. Scorecard: Plasmas -- 4 Fizzles -- 5 Duds -- 5 total cycles 14 |
| Session Leader Comments |
| Physics Operator Comments | |||
| Jun 19 2001 11:50:06:970AM | Earl Marmar | Run Plan for Tuesday June 19, 2001 1010619 MP215 J-port Conditioning SL: Boivin PO: Marmar Engineering setup: ECDC in D2 overnight Run starts at Noon Power systems as on 1010612014. Gas setup: fill B-top with 6 psi of D2 Hybrid enabled (PG4) fill B-side lower with 1 psi of Ar Hybrid enabled (PG1) fill B-side upper with 30 psi of D2 Hybrid DISABLED (PG2) fill C-side with 30 psi of D2 Hybrid enabled (PG3) fill J-bottom with 30 psi of He Hybrid DISABLED (PG5) Enable the following gate valves: ECE, DNB, and VUV. Open the Z-bolo shutter for plasma shots (closed during ECDC). Be set up for between-shot ECDC. Run plan: The goal of the run is to continue bringing J-port into full operation. | |
| Jun 19 2001 11:52:00:347AM | Earl Marmar | coldstart hybrid no errors, all matrices respond load from 1010612014 change TF invert to 1.5 seconds (was 3.65) ECDC for 15 minutes just before the run (J-port vacuum conditioning was done about 1 hour before the run started) | |
| Jun 19 2001 12:44:50:867PM | 1010619001 | Earl Marmar | dud fields look ok Fill is on the low side (0.06 vs 0.08 on 1010612014) |
| Jun 19 2001 01:02:18:483PM | 1010619002 | Earl Marmar | add 4 msec to PG4 (now 28 msec) dud |
| Jun 19 2001 01:25:57:630PM | 1010619003 | Earl Marmar | ECDC for 7 minutes before shot reduce pg4 prepuff to 22 msec dud |
| Jun 19 2001 01:38:27:680PM | 1010619004 | Earl Marmar | add .5 mT to BR0 dud |
| Jun 19 2001 02:04:37:567PM | 1010619005 | Earl Marmar | EF4 15 amp more negative before t=0 (now -1285 A) fizzle; looks like it bounced to the outside |
| Jun 19 2001 02:20:13:450PM | 1010619006 | Earl Marmar | raise prepuff by 3 msec to 25 msec very late breakdown; no current rise according to gauge, prefill did not change (valve was open for 25 msec) |
| Jun 19 2001 02:33:32:733PM | 1010619007 | Earl Marmar | reduce BR0 by 1 mT to 1.5 mT fizzle very fast current rise |
| Jun 19 2001 02:57:01:193PM | 1010619008 | Earl Marmar | ECDC for 10 minutes before shot add 2 msec to prepuff (now 27 msec) fizzle |
| Jun 19 2001 03:16:35:910PM | 1010619009 | Earl Marmar | BR0 to .002 Prepuff to 24 msec plasma large hesitation during current rise |
| Jun 19 2001 03:43:04:497PM | 1010619010 | Earl Marmar | EF4 10 less negative before t=0 (now -1275) plasma better current rise |
| Jun 19 2001 04:04:21:763PM | 1010619011 | Earl Marmar | no pcs changes plasma |
| Jun 19 2001 04:23:20:180PM | 1010619012 | Earl Marmar | ECDC for 10 minutes before shot (P=4e-4 D2) fizzle, slightly late breakdown |
| Jun 19 2001 04:42:03:490PM | 1010619013 | Earl Marmar | no pcs changes dud There is evidence on the RGA of a significant increase in masses 28 and 14 (probably F port) (increasing over the last few hours) |
| Jun 19 2001 05:04:37:943PM | 1010619014 | Earl Marmar | EF4 10 A more negative before t=0 (now -1285 A) plasma |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 12:34:39:177PM | Plasma | Ok | |
| 2 | 12:49:47:717PM | Plasma | Ok | |
| 3 | 01:09:53:577PM | Plasma | Ok | |
| 4 | 01:31:02:153PM | Plasma | Ok | |
| 5 | 01:56:55:600PM | Plasma | Ok | |
| 6 | 02:11:28:153PM | Plasma | Ok | |
| 7 | 02:25:30:363PM | Plasma | Ok | |
| 8 | 02:52:02:590PM | Plasma | Ok | |
| 9 | 03:06:15:080PM | Plasma | Bad | EF2L fault after shot. |
| 10 | 03:32:47:123PM | Plasma | Ok | |
| 11 | 03:54:44:157PM | Plasma | Ok | |
| 12 | 04:18:28:217PM | Plasma | Ok | |
| 13 | 04:36:50:607PM | Plasma | Ok | |
| 14 | 04:50:23:110PM | Plasma | Ok | |