Alcator C-Mod Run 1020822 Information

Back to runs

Miniproposals
Miniproposal:
Date Filed:
Title:
First Author:
Session Leader:Yijun Lin (shots 1-21)
Session Leader:Steve Wukitch (shots 1-21)

Operators
Session leader(s):Yijun Lin,Steve Wukitch
Physics operator(s):Earl Marmar,Joseph Snipes
Engineering operator(s):Bill Cochran,Ed Fitzgerald,Bill Parkin

Engineering Operator Run Comment
Characterize J antenna @ 2MW. Wukitch/Lin/Snipes/Cochran/Fitzgerald/Par

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:29:833PM
Author: To Be Determined
Engineering setup for Thursday 22 Aug 2002

Session leader: S. Wukitch, Y. Lin
Physics operator: J. Snipes

ECDC in the morning, if possible, stopping by 07:00.
Set up for possible ECDC in D2 between shots.

Run begins at 09:00 and ends at 17:00.

Set up power systems as on 1020821003.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
fill B-side upper with 10 psi D2 Hybrid DISABLED (PG2) (for ECDC)
fill C-side with 30 psi D2 Hybrid enabled (PG3)
leave J-Bottom as is Hybrid DISABLED (PG5)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB
-------------------------------------------------------------------------------
RF Setup: FMIT#2,3&4 transmitters in Run On by 07:00.
-------------------------------------------------------------------------------
Run Plan:

Characterize J antenna @ 2 MW.

@4.6T power ramp [0.1-2.0 MW] (2 shots)
@4.6T current scan = 0.7,0.9,1.1 MA (5 shots)
@4.6T gap scan [0.5,1.0,1.5,2.0] (6 shots)
@4.6T density scan [0.6,1.0,1.2] (4 shots)
BT scan 3.8,4.2,5.0,5.4 T (6 shots) (0.9 MA)

using discharge with lightest loading - maximize peak voltage (10 shots)
@5.0 T maximize RF power to plasma (infinite)

-------------------------------------------------------------------------------

001
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 0.2-2 MW ramp [0.6,1.5] sec
result: early disruption ~0.17 sec
J injection kill
002
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 0.2-2 MW ramp [0.6,1.5] sec
result: plasma
J: 0.2-2 MW ramp with faulting
action: repeat
003
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 0.2-2 MW ramp [0.6,1.5] sec
result: plasma
J: 0.2-2 MW ramp with faulting
action: try some power conditioning 1 MW sec pulse
004
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 1.0 MW ramp [0.6,1.5] sec
result: plasma - EDA
J: 1.0 MW with 3 faults - much better
action: raise power to 1.4 MW on J
start E [1.2,1.5] sec @1 MW
005
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.0 MW [1.2,1.5] sec
J: 1.4 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.0 MW
J: 1.4 MW with 3 faults - better
action: J to 1.8 MW
E to 1.3 MW
006
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.3 MW [1.2,1.5] sec
J: 1.8 MW [0.6,1.5] sec
result: plasma - EDA injection from J - K-side of septum @midplane
E: 1.3 MW with multiple faults
J: 1.8 MW with 2 faults
action: J to 2.2 MW
E to 1.2 MW
007
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.2 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.2 MW with 3 faults
J: 2.2 MW with max faults
action: repeat
008
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.2 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.2 MW clean
J: 2.2 MW with max faults but better
action: E to 1.4 MW
009
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.4 MW 2 faults
J: 2.2 MW with 8 faults
action: repeat
010
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.4 MW 3 faults
J: 2.2 MW with 8 faults
action: J to 2.6 MW
011
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.6 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 3 faults
J: 2.6 MW with max faults
action: repeat
012
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.6 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 3 faults
J: 2.6 MW with max faults
action: repeat
013
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.6 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 2 faults
J: 2.6 MW with max faults
action: lower density to 0.8 and lower J to 2.4 MW
014
request: SN, BT~4.5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.4 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 2 faults
J: 2.4 MW 3 faults
action: dynamic gap scan 1 cm to 2 cm 0.7 to 1.5 sec
J to 2 MW
E off
015
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0-2.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: fizzle
016
request: SN, BT~4.5 T, nl_04~0.8, Ip~0.75, right ~1.0-2.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA 1-6 cm
E: 0 MW
J: 2.0 MW max faults once gap reaches 2 cm
action: dynamic Ip scan 0.75-1.1 MA 0.7 to 1.5 sec
note: interesting ohmic H-mode at 4.6T with gap 2 cm
017
request: SN, BT~4.5 T, nl_04~0.8, Ip~0.75-1.1, right ~1.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA
E: 0 MW
J: 2.0 MW clean
action: BT->4.2
018
request: SN, BT~4.2 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA
E: 0 MW
J: 2.0 MW clean
action: BT->5.0 T and E->1.0 MW [1.2,1.5] sec
019
request: SN, BT~5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.0 MW
J: 2.0 MW clean
action: J -> 2.4 MW and E->1.3 MW [0.6,1.5] sec
020
request: SN, BT~5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.4 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW two faults
J: 2.4 MW two faults
action: J -> 2.8 MW and E->1.4 MW [0.8,1.5] sec
021
request: SN, BT~5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.8 MW [0.6,1.5] sec
result: plasma - EDA -early disruption ~1.2 sec
E: 1.4 MW 6 faults
J: 2.8 MW 4 faults

Summary:

After a late start and vacuum conditioning both E and J to 39 kV, we
began with the intent of characterizing the J-port antenna at 70 MHz.
We were side tracked early by excessive faulting so we power
conditioned to 2.6 MW. We modified the run plan to include a dynamic
scan of the right gap and plasma current which were successful. The
right gap scan showed that the J-port can couple out to 2 cm without
significantly lowering the loading in EDA (5.8->5.25 ohms). The
current scan suggested an even weaker dependence. We then did an
abbreviated field scan and coupled 2.8 MW from J into a 5 T discharge.
The antenna operated well into both low field and high field side
resonance positions. Further tests at 3.8 T and 5.4 T will be
necessary to complete this scan. We skipped the maximizing the
voltage since we expect that this can be found in piggyback. The
conditioning required at the beginning of the day is troublesome. We
hope this not necessary everyday. It appears that E-port has trouble
(multiple faults) at high power (>1.2 MW) and J-port has trouble at >1
MW. J-port quickly conditioned to 1.8 MW but took 7 shots to
condition to 2.4 MW. We conclude that vacuum conditioning is no
longer improving the antenna performance in plasma operation. We
think approaching high power operation requires starting at moderate
power levels and working up. On Tuesday, we tried going right to 2 MW
but the faulting never ceased.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:15:897PM
Author: To Be Determined
Engineering setup for Thursday 22 Aug 2002

Session leader: S. Wukitch, Y. Lin
Physics operator: J. Snipes

ECDC in the morning, if possible, stopping by 07:00.
Set up for possible ECDC in D2 between shots.

Run begins at 09:00 and ends at 17:00.

Set up power systems as on 1020821003.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
fill B-side upper with 10 psi D2 Hybrid DISABLED (PG2) (for ECDC)
fill C-side with 30 psi D2 Hybrid enabled (PG3)
leave J-Bottom as is Hybrid DISABLED (PG5)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB
-------------------------------------------------------------------------------
RF Setup: FMIT#2,3&4 transmitters in Run On by 07:00.
-------------------------------------------------------------------------------
Run Plan:

Characterize J antenna @ 2 MW.

@4.6T power ramp [0.1-2.0 MW] (2 shots)
@4.6T current scan = 0.7,0.9,1.1 MA (5 shots)
@4.6T gap scan [0.5,1.0,1.5,2.0] (6 shots)
@4.6T density scan [0.6,1.0,1.2] (4 shots)
BT scan 3.8,4.2,5.0,5.4 T (6 shots) (0.9 MA)
using discharge with lightest loading - maximize peak voltage (10 shots)
@5.0 T maximize RF power to plasma (infinite)

Summary: We had a late start today due to damage yesterday in the alternator
circuits where fuses and resistors needed to be replaced. We started just after
noon. ICRF coupling studies were performed on the J-port antenna and we made
progress on understanding the coupling. We had 21 pulses of which 20 had plasma
and one fizzle. Shot 1 disrupted early, but the other 19 plasmas were full
length. Overall, it was a reasonably successful run despite the delay.

Shot 1: Marmar sitting in as physop for Snipes until about 12:30
10 minutes of ECDC before shot 1 (ICRF was vacuum conditioning)
load from 1020821003; reduce PG-4 prefill puff to 25 msec from 27
plasma disrupt at 0.17 seconds (big injection; wide view indicates
vicinity of J-port)
Shot 2: increase prepuff (PG-4) to 27 msec from 25 plasma
Snipes now taking over as physop
Shot 3: Repeat. Good shot!
Shot 4: Repeat. Good shot!
Shot 5: Repeat. Good shot!
Shot 6: Repeat. Good shot!
Shot 7: Repeat. Increase Ar puff to 40 ms duration. Good shot!
Shot 8: Repeat. D puff added at 1.5 s by Jim Terry. Good shot!
Shot 9: Repeat. Good shot!
Shot 10: Repeat. Good shot!
Shot 11: Repeat. Good shot!
Shot 12: Repeat. Good shot!
Shot 13: Repeat. Good shot!
Shot 14: Repeat. Good shot!
Shot 15: Fizzle!
Shot 16: RCUR ramp by 2 cm inward to increase the outer gap from 0.7 s - 1.6 s.
Good shot, though it was a bit aggressive on the gap scan. I should
have ramped RCUR by 1 cm instead.
Shot 17: Reloaded shot 14 to remove the gap scan then added a ramp in Ip from
0.7 s - 1.5 s ramping from 0.8 MA to 1.1 MA. Good shot.
Shot 18: Reloaded shot 14 and then reduced the TF current from -127 kA to
-116 kA during the flattop to reduce the TF to 4.2 T. Good shot.
Shot 19: Increased the TF current to -140.7 kA during the flattop to increase
the TF to 5.0 T. Good shot.
Shot 20: Repeat. Good shot.
Shot 21: Repeat. Good shot.


Session Leader Comments
Aug 22 2002 12:41:55:087PM1020822002Steve Wukitch002
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 0.2-2 MW ramp [0.6,1.5] sec
result: plasma
J: 0.2-2 MW ramp with faulting
action: repeat
Aug 22 2002 01:01:45:233PM1020822003Steve Wukitch003
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 0.2-2 MW ramp [0.6,1.5] sec
result: plasma
J: 0.2-2 MW ramp with faulting
action: try some power conditioning - 1 MW sec pulse
Aug 22 2002 01:11:25:627PM1020822004Steve Wukitch004
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 0 MW
J: 1.0 MW ramp [0.6,1.5] sec
result: plasma - EDA
J: 1.0 MW with 3 faults - much better
action: raise power to 1.4 MW on J
start E [1.2,1.5] sec @1 MW
Aug 22 2002 01:23:21:337PM1020822005Steve Wukitch005
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.0 MW [1.2,1.5] sec
J: 1.4 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.0 MW
J: 1.4 MW with 3 faults - better
action: J to 1.8 MW
E to 1.3 MW
Aug 22 2002 01:41:06:857PM1020822006Steve Wukitch006
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.3 MW [1.2,1.5] sec
J: 1.8 MW [0.6,1.5] sec
result: plasma - EDA injection from J - K-side of septum @midplane
E: 1.3 MW with multiple faults
J: 1.8 MW with 2 faults
action: J to 2.2 MW
E to 1.2 MW
Aug 22 2002 01:48:07:750PM1020822007Steve Wukitch007
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.2 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.2 MW with 3 faults
J: 2.2 MW with max faults
action: repeat
Aug 22 2002 02:05:21:930PM1020822008Steve Wukitch008
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.2 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.2 MW clean
J: 2.2 MW with max faults but better
action: E to 1.4 MW
Aug 22 2002 02:23:13:563PM1020822009Steve Wukitch009
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.4 MW 2 faults
J: 2.2 MW with 8 faults
action: repeat
Aug 22 2002 02:39:25:743PM1020822010Steve Wukitch010
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.2 MW [0.6,1.5] sec
result: plasma - EDA another injection from J
E: 1.4 MW 3 faults
J: 2.2 MW with 8 faults
action: J to 2.6 MW
Aug 22 2002 02:47:45:310PM1020822011Steve Wukitch011
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.6 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 2 faults
J: 2.6 MW with max faults
action: repeat
Aug 22 2002 03:05:11:673PM1020822012Steve Wukitch012
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.6 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 2 faults
J: 2.6 MW with max faults
action: repeat
Aug 22 2002 03:16:34:397PM1020822013Steve Wukitch013
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.6 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 2 faults
J: 2.6 MW with max faults
action: lower density to 0.8 and lower J to 2.4 MW
Aug 22 2002 03:35:40:077PM1020822014Steve Wukitch014
request: SN, BT~4.5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.4 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW 2 faults
J: 2.4 MW 3 faults
action: dynamic gap scan 1 cm to 2 cm 0.7 to 1.5 sec
J to 2 MW
E off
Aug 22 2002 03:45:28:643PM1020822015Steve Wukitch015
request: SN, BT~4.5 T, nl_04~1, Ip~0.75, right ~1.0-2.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.4 MW [0.6,1.5] sec
result: fizzle
Aug 22 2002 04:22:00:580PM1020822016Steve Wukitch016
request: SN, BT~4.5 T, nl_04~0.8, Ip~0.75, right ~1.0-2.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA 1-6 cm
E: 0 MW
J: 2.0 MW max faults once gap reaches 2 cm
action: dynamic Ip scan 0.75-1.1 MA 0.7 to 1.5 sec
note: interesting ohmic H-mode at 4.6T with gap 2 cm
Aug 22 2002 04:26:22:533PM1020822017Steve Wukitch017
request: SN, BT~4.5 T, nl_04~0.8, Ip~0.75-1.1, right ~1.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA
E: 0 MW
J: 2.0 MW clean
action: BT->4.2
Aug 22 2002 04:35:12:567PM1020822018Steve Wukitch018
request: SN, BT~4.2 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA
E: 0 MW
J: 2.0 MW clean
action: BT->5.0 T and E->1.0 MW [1.2,1.5] sec
Aug 22 2002 04:40:47:010PM1020822019Steve Wukitch019
request: SN, BT~5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.0 MW [1.2,1.5] sec
J: 2.0 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.0 MW
J: 2.0 MW clean
action: J -> 2.4 MW and E->1.3 MW [0.6,1.5] sec
Aug 22 2002 04:59:24:390PM1020822020Steve Wukitch020
request: SN, BT~5 T, nl_04~0.8, Ip~0.75, right ~1.0 cm
E: 1.4 MW [1.2,1.5] sec
J: 2.4 MW [0.6,1.5] sec
result: plasma - EDA
E: 1.4 MW two faults
J: 2.4 MW two faults
action: J -> 2.8 MW and E->1.4 MW [0.8,1.5] sec

Physics Operator Comments
Aug 22 2002 11:39:29:313AMEarl MarmarDate: 21-AUG-2002 14:22 Expires: 4-SEP-2002 00:00
From: SPANNA::SNIPES
Subj: Run Plan for Thursday 1020822

Engineering setup for Thursday 22 Aug 2002

Session leader: S. Wukitch, Y. Lin
Physics operator: J. Snipes

ECDC in the morning, if possible, stopping by 07:00.
Set up for possible ECDC in D2 between shots.

Run begins at 09:00 and ends at 17:00.

Set up power systems as on 1020821003.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
fill B-side upper with 10 psi D2 Hybrid DISABLED (PG2) (for ECDC)
fill C-side with 30 psi D2 Hybrid enabled (PG3)
leave J-Bottom as is Hybrid DISABLED (PG5)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB
-------------------------------------------------------------------------------
RF Setup: FMIT#2,3&4 transmitters in Run On by 07:00.
-------------------------------------------------------------------------------
Run Plan:

Characterize J antenna @ 2 MW.

@4.6T power ramp [0.1-2.0 MW] (2 shots)
@4.6T current scan = 0.7,0.9,1.1 MA (5 shots)
@4.6T gap scan [0.5,1.0,1.5,2.0] (6 shots)
@4.6T density scan [0.6,1.0,1.2] (4 shots)
BT scan 3.8,4.2,5.0,5.4 T (6 shots) (0.9 MA)

using discharge with lightest loading - maximize peak voltage (10 shots)
@5.0 T maximize RF power to plasma (infinite)
Aug 22 2002 11:40:49:223AMEarl Marmarcoldstart hybrid

all matrices respond; no errors in log
Aug 22 2002 12:26:12:563PM1020822001Earl MarmarMarmar sitting in as physop for Snipes until about 12:30

10 minutes of ECDC before shot 1 (ICRF was vacuum conditioning)

load from 1020821003; reduce PG-4 prefill puff to 25 msec from 27

plasma

disrupt at 0.17 seconds (big injection; wide view indicates vicinity of J-port)
Aug 22 2002 12:35:47:677PM1020822002Earl Marmarincrease prepuff (PG-4) to 27 msec from 25

plasma

Snipes now taking over as physop
Aug 22 2002 01:05:44:907PM1020822003Joseph SnipesShot 3: Repeat. Good shot!
Aug 22 2002 01:05:58:987PM1020822004Joseph SnipesShot 4: Repeat. Good shot!
Aug 22 2002 01:36:01:513PM1020822005Joseph SnipesShot 5: Repeat. Good shot!
Aug 22 2002 01:36:17:480PM1020822006Joseph SnipesShot 6: Repeat. Good shot!
Aug 22 2002 02:00:46:710PM1020822007Joseph SnipesShot 7: Repeat. Increase Ar puff to 40 ms duration. Good shot!
Aug 22 2002 02:02:41:600PM1020822008Joseph SnipesShot 8: Repeat. D puff added at 1.5 s by Jim Terry. Good shot.
Aug 22 2002 02:18:48:903PM1020822009Joseph SnipesShot 9: Repeat. Good shot!
Aug 22 2002 02:58:51:407PM1020822010Joseph SnipesShot 10: Repeat. Good shot!
Aug 22 2002 02:59:01:437PM1020822011Joseph SnipesShot 11: Repeat. Good shot!
Aug 22 2002 02:59:12:047PM1020822012Joseph SnipesShot 12: Repeat. Good shot!
Aug 22 2002 03:16:38:333PM1020822013Joseph SnipesShot 13: Repeat. Good shot!
Aug 22 2002 04:15:48:000PM1020822014Joseph SnipesShot 14: Repeat. Good shot.
Aug 22 2002 03:55:53:163PM1020822015Joseph SnipesShot 15: Fizzle!
Aug 22 2002 04:04:45:277PM1020822016Joseph SnipesShot 16: RCUR ramp by 2 cm inward to increase the outer gap from 0.7 s - 1.6 s. Good shot, though it was a bit
aggressive on the gap scan. I should have ramped RCUR by 1 cm instead.
Aug 22 2002 04:15:22:857PM1020822016Joseph SnipesShot 17: Reloaded shot 14 to remove the gap scan then added a ramp in Ip from
0.7 s - 1.5 s ramping from 0.8 MA to 1.1 MA. Good shot.
Aug 22 2002 04:24:50:517PM1020822018Joseph SnipesShot 18: Reloaded shot 14 and then reduced the TF current from -127 kA to
-116 kA during the flattop to reduce the TF to 4.2 T. Good shot.
Aug 22 2002 04:43:35:120PM1020822019Joseph SnipesShot 19: Increased the TF current to -140.7 kA during the flattop to increase
the TF to 5.0 T. Good shot.
Aug 22 2002 04:53:35:823PM1020822020Joseph SnipesShot 20: Repeat. Good shot.
Aug 22 2002 05:05:53:893PM1020822021Joseph SnipesShot 21: Repeat. Good shot.
Aug 22 2002 05:11:37:630PM1020822021Joseph SnipesSummary: We had a late start today due to damage yesterday in the alternator
circuits where fuses and resistors needed to be replaced. We started just after
noon. ICRF coupling studies were performed on the J-port antenna and we made
progress on understanding the coupling. We had 21 pulses of which 20 had plasma
and one fizzle. Shot 1 disrupted early, but the other 19 plasmas were full
length. Overall, it was a reasonably successful run despite the delay.

Engineering Operator Comments
ShotTimeTypeStatusComment
112:13:11:240PMPlasmaOk
212:34:09:037PMPlasmaOk
312:50:27:400PMPlasmaOk
401:03:47:470PMPlasmaOk
501:16:27:880PMPlasmaOk
601:29:13:353PMPlasmaOk
701:41:57:623PMPlasmaOk
802:00:17:960PMPlasmaOk
902:15:10:717PMPlasmaOk
1002:28:02:580PMPlasmaOk
1102:42:04:040PMPlasmaOk
1202:57:04:750PMPlasmaOk
1303:09:57:800PMPlasmaOk
1403:27:16:230PMPlasmaOk
1503:41:53:690PMPlasmaOk
1603:54:43:910PMPlasmaOk
1704:10:24:277PMPlasmaOk
1804:23:16:690PMPlasmaOk
1904:36:16:210PMPlasmaOk
2004:49:12:543PMPlasmaOk
2105:02:04:830PMPlasmaOk