Run Plan and Engineering Setup for Wed. 9/11/2002

RF Conditioning and Machine Cleanup
SL: Wukitch/Lin
PO: Wolfe

Engineering Setup

Power Systems as on 1020903001
Overnight ECDC in D2 at 2e-5 torr
If possible, find and fix possible leak observed on 1020910

Run to begin at 9:00 AM

Gas setup:

B-Top 6 psi D2 Hybrid Enabled (PG4)
B-side lower 1 psi Ar Hybrid Enabled (PG1)
B-side upper 10 psi D2 Hybrid DISABLED (PG2, for ECDC)
C-Side 30 psi D2 Hybrid Enabled (PG3)
J-Bottom as is, Hybrid DISABLED

Enable the following gate valves, assuming no vacuum problems:
ECE,VUV,DNB

RF Setup: Transmitters #1,2,3,4 in run-on by 7:00

Run Plan: Start with ten minutes of ECDC in D2 following RF conditioning

Begin with a "standard" 5.3T, 1MA SN target shot, e.g. 1020903004
Do RF conditioning and monitor ohmic performance, H/D, Prad to assess
clean-up.

shots not explicitly listed were either cycle tests, duds, or fizzles
003 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 0.6 MW [0.7,1.5] sec
E: 0.6 MW [0.6,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: 0.6 MW clean
E: 0.6 MW max faults but they appear to be false high voltage faults
J: max faults but ran a bit
007 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 0.8 MW [0.7,1.5] sec
E: 0.6 MW [0.6,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma H-mode!
D: 0.8 MW 1 fault
E: 0.6 MW max faults but they appear to be false high voltage faults
J: max faults
009 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.2 MW [0.7,1.5] sec
E: 0.6 MW [0.6,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma nl04~0.4 way low
D: 1.3 MW 1 fault
E: 0.6 MW max faults but they appear to be false high voltage faults
J: max faults
EI12 and EI34 phase are at different values from last ops. Power
cycling the supplies did not fix the problem.


010 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.2 MW [0.7,1.5] sec
E: 0.6 MW [0.6,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: max faults - false voltage limit
E: 0.6 MW 4 faults
J: 1.2 max faults
011 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.2 MW [0.7,1.5] sec
E: 0.8 MW [0.6,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: max faults - false voltage limit
E: 0.9 MW clean
J: max faults
012 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.2 MW [0.6,1.5] sec
E: 1.1 MW [0.7,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: 1.2 MW [0.6,1.5] sec
E: max faults - false phase balance
J: max faults
013 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.4 MW [0.6,1.0] sec
E: 1.1 MW [0.9,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: 1.3 MW clean
E: 1.2 MW 1 fault (failed during overlap)
J: max faults
raised phase balance threshold
015 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.4 MW [0.6,1.0] sec
E: 1.3 MW [0.9,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: 1.6 MW clean
E: 1.4 MW 1 fault (failed during overlap)
J: max faults
017 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.55 MW [0.6,1.0] sec
E: 1.4 MW [0.9,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma
D: 1.7 MW 2 faults
E: 1.6 MW 1 fault (failed during overlap)
J: max faults
018 early disruption check the
019 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.55 MW [0.6,1.0] sec
E: 1.4 MW [0.9,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma small BT ramp to 5.1T starting at 1.1 sec
D: 1.7 MW 2 faults
E: 1.6 MW 1 fault (failed during overlap)
J: max faults
020 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.55 MW [0.6,1.0] sec
E: 1.4 MW [0.9,1.5] sec
J: 1.2 MW [0.7,1.5] sec
result: plasma small BT ramp to 5.0T starting at 1.1 sec
D: 1.7 MW 2 faults
E: 1.6 MW 1 fault (failed during overlap)
J: max faults
022 lower SN, BT~5.4 T,nl04~0.8, Ip~1 MA
D: 1.55 MW [0.7,1.0] sec
E: 1.4 MW [1.0,1.5] sec
J: 1.2 MW [0.5,1.0] sec
result: plasma small BT ramp to 4.9T starting at 1.1 sec
D: 1.7 MW 2 faults
E: 1.6 MW 3 fault (failed during overlap)
J: max faults - ran better before D came on
023 lower SN, BT~5.15 T,nl04~0.8, Ip~1 MA
D: 1.55 MW [0.9,1.1] sec
E: 1.4 MW [1.1,1.5] sec
J: 1.2 MW [0.5,1.0] sec
result: plasma
D: 1.7 MW clean
E: 1.4 MW clean
J: max faults - bad match
024 lower SN, BT~5.15 T,nl04~0.8, Ip~1 MA
D: 1.5 MW [1.0,1.25] sec
E: 1.5 MW [1.25,1.5] sec
J: 1.4 MW [0.5,1.0] sec
result: plasma
D: 1.5 MW clean
E: 1.5 MW clean
J: 1.4 MW max faults best shot since 003
good H(D) mode conversion
026 lower SN, BT~5.15 T,nl04~0.8, Ip~1 MA
D: 1.4 MW [1.0,1.25] sec
E: 1.4 MW [1.25,1.5] sec
J: 1.2 MW [0.5,1.0] sec
result: plasma
D: 1.4 MW clean
E: 1.4 MW clean
J: 1.4 MW 6 faults
good H(D) mode conversion on axis
028 lower SN, BT~5.15 T,nl04~0.8, Ip~1 MA
J: 1.4 MW [0.5,1.0] sec
result: plasma
J: 1.4 MW 6 faults
good H(D) mode conversion

Summary:

RF operation was reasonable given the high H fraction. The antennas
had difficulty operating with one another because of the increased
cross talk between antennas due to single pass poor absorption. D and
E-port antennas operated up to 1.6 MW into L-mode plasmas. J-port was
hampered by the high cross coupled power from D and E-port and reached
only 1.4 MW. The H-mode on 007 was encouraging but the only one of
the day. On the last few shots 024, 026, and 028, direct electron
heating was observed on the central channels. Using cold plasma
dispersion relation and measured H/D ratio, the heating is consistent
with mode conversion heating. This is the first clear indication of
D(H) mode conversion on C-Mod. An interesting disruption was observed
with the wide1 and wide2 cameras on shot 018. A projectile was
launched from the A-port divertor region, bounced off the inner wall,
disrupted the plasma, and landed in the neighborhood of the D-port
divertor area.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:16:100PM
Author: To Be Determined
Physics Operator Summary for Wednesday, 1020911

RF Conditioning and Machine Cleanup
SL: Wukitch/Lin
PO: Wolfe

Engineering Setup:

Power Systems as on 1020903001
Overnight ECDC in D2 at 2e-4 torr (not 2e-5 as I had said in the bulletin)

Run to begin at 9:00 AM
Gas setup:

B-Top 6 psi D2 Hybrid Enabled (PG4)
B-side lower 1 psi Ar Hybrid Enabled (PG1)
B-side upper 10 psi D2 Hybrid DISABLED (PG2, for ECDC)
C-Side 30 psi D2 Hybrid Enabled (PG3)
J-Bottom as is, Hybrid DISABLED

Enable the following gate valves, assuming no vacuum problems:
ECE,VUV,DNB

RF Setup: Transmitters #1,2,3,4 in run-on by 7:00

Run Plan: Start with ten minutes of ECDC in D2 following RF conditioning

Begin with a "standard" 5.3T, 1MA SN target shot, e.g. 1020903004
(actually, that's probably 5.1T, which is even better).
Do RF conditioning and monitor ohmic performance, H/D, Prad to assess
clean-up.


Results:

I tweaked up the current waveform and gain times from the starting seg2 shot,
1020903004 and copied in a pg3 waveform. I also cut back the Argon
pulse a little, just for luck.

It was rough going in the morning, with very erratic startups, including duds
and fizzles. The plasmas that went were disrupting in early rampdown, mostly
with vertical instabilities, some with injections. Reducing elongation
(clearin) fixed the vertical problems. We ran ecdc after disruptive shots,
which may or may not have helped. The pumpdown after plasmas and after ecdc
was very slow.

Things got better after shot 9 or so. The RF group got D&E operating up to
about 1.6MW each, running separately. Since the H/D never got below about .17
at 0.5 sec, and rose to .38 or so during the RF pulse, the damping was poor
and the cross-talk between the two was causing faulting. This was also true
for J, which ended up only going up to about 1.3MW today. Obviously at these
H/D the heating efficiency was poor, but we did get h-modes on shot 7, and a
very brief one on 13.

On shots 18-22 we did TF rampdowns starting at 1.1sec to determine the field
setting at which the 80MHz (E) had the largest sawteeth. This turned out to
be -145000A, nominally 5.15T (vacuum). The rest of the run was carried out at
this field. According to Amanda, the GPC indicated that the actual field was
5.25T on axis at this field, which is consistent with the 80MHz proton
resonance. Evidence continues to point to the Btor signal being low by at
least 1%. Integrator calibrations are underway as I write this.

At these high H/D ratios there is a significant mode conversion damping on the
high field side of the minority resonance. At this field the MC layer for the
70MHz was on axis and the ECE indicated very localized electron heating. This
is a nice physics result.

There were several duds later in the day, and the cure seemed to be 5 miuntes
of ecdc. I suspect this was related to the fact that J started putting in
significant power on the preceeding shots. Breakdown times on the shots that
went were all over the place, from 5.5msec to 9msec. The fields could probably
still use some tweaking. IGT pressure on going into init was typically around
3-4e-6, after good shots or after ecdc. That seemed to have something to do
with the late breakdown times. On shots with a long delay from the previous
shot and no ecdc the breakdown times were earlier.

Several shots, particularly later in the day, had disruptions in early
rampdown, like 1.6 sec, for no obvious reason. At shot 24 I made a number of
changes to the rampdown waveforms (clearin, rcur, and nl04) which seemed to
avoid the disruption. However on the last shot 28 the disruption happened
again, at almost exactly the same time.

On the good side of the startup problem, we had no instances of runaways
today. I think the increased Bz from yesterday is probably responsible, since
we ran at very low pre-puff (20msec) without bouncers or hards.

The TCI feedback had a problem on shot #3, and I went to pre-programmed gas
for shots 7-9. Shot 9 gave much lower density than 7 with the same gas puff,
possibly indicating the walls were cleaning up. Anyway, from shot#10 on the
tci feedback was back on, with gain=8.0.

Shot #14 was a power supply dud. Both oh2 supplies failed to fire; possible
camac problem, not explained. There was a disruption at crossover on shot 18,
caused by an injection (UFO) which is clearly seen on the wide1 video; this caused
the PF breaker to pull. No fuses were lost.



Scorecard:
----------

28 shots. 17 plasmas. 5 fizzles. 6 duds.

Session Leader Comments
Sep 11 2002 09:15:08:013AM1020911001Yijun LinPlasma request: 5.4 T, 1.0 MA, ne 0.8e20, SN
RF request:
D: 0.6 MW, [0.6, 1.5] sec
E: 0.6 MW, [0.6, 1.5] sec
J: 1.2 MW, [0.6, 1.5] sec
Result: fizzle
Sep 11 2002 10:12:51:083AM1020911004Yijun Linfizzle
Sep 11 2002 10:34:53:590AM1020911005Yijun Lindud
Sep 11 2002 10:35:12:073AM1020911006Yijun Lindud
Sep 11 2002 11:56:06:650AM1020911008Yijun Linfizzle

Physics Operator Comments
Sep 11 2002 12:19:47:033PMSteve Wolfeload seg 2 from 1020903004
Turns out the tf was set for 5.4T (153kA). Leave it for now,
change to 5.1T (144300) later, if Steve wants to.

Decrease gas puff in seg1 from 24msec to 20msec, anticipating
ecdc before first shot.
Raise Ip waveform point at 0.1sec from -450000 to -600000
point at .2sec from -700000 to -800000.
Move Ip gain step from .64sec to .5sec
Copy a pg3 waveform from seg 4 to seg2
reduce Ar puff from 30msec to 25msed
load/clean
coldstart
all matrices respond
hloader log shows no errors, Total of 521216 words loaded to DAC cards
Sep 11 2002 12:20:10:110PMSteve WolfeRun Plan and Engineering Setup for Wed. 9/11/2002

RF Conditioning and Machine Cleanup
SL: Wukitch/Lin
PO: Wolfe

Engineering Setup

Power Systems as on 1020903001
Overnight ECDC in D2 at 2e-4 torr (not 2e-5 as I had said in the bulletin)
If possible, find and fix possible leak observed on 1020910

Run to begin at 9:00 AM
Gas setup:

B-Top 6 psi D2 Hybrid Enabled (PG4)
B-side lower 1 psi Ar Hybrid Enabled (PG1)
B-side upper 10 psi D2 Hybrid DISABLED (PG2, for ECDC)
C-Side 30 psi D2 Hybrid Enabled (PG3)
J-Bottom as is, Hybrid DISABLED

Enable the following gate valves, assuming no vacuum problems:
ECE,VUV,DNB

RF Setup: Transmitters #1,2,3,4 in run-on by 7:00

Run Plan: Start with ten minutes of ECDC in D2 following RF conditioning

Begin with a "standard" 5.3T, 1MA SN target shot, e.g. 1020903004
(actually, that's probably 5.1T, which is even better).
Do RF conditioning and monitor ohmic performance, H/D, Prad to assess
clean-up.
Sep 11 2002 09:15:17:950AM1020911001Steve Wolfeshot#1: fizzle.
Too much gas or bz too positive. Actually, it looks like
the latter, even though I had them start init with 3.6e-6 Torr.

next shot: just repeat, and see if the fields change on their own;
I know the gas will
Sep 11 2002 09:28:52:030AM1020911002Steve Wolfeshot#2: dud
bz is still too positive.
next shot: ic_ef4 from -1300 to -1315
raise pg4 to 23msec
Sep 11 2002 09:51:11:313AM1020911003Steve Wolfeshot 3: plasma disrupted at 1.5sec
late breakdown 9msec
got up to 1.4MW rf, no h-mode.
sawteeth get very weird after 1.25sec
density feedback goes nuts after 1.25. Irby has gone swimming.
looks like a vertical disruption, li is growing, n/nc gets to 1.28!

next shot:
change to pre-program gas only, extend gas puff to 1.5sec
decrease clearin from .016 to .010, rcur from .6615 to .6585
Sep 11 2002 10:00:31:540AM1020911004Steve Wolfeshot 4: change to pre-program gas only, extend gas puff to 1.5sec
decrease clearin from .013,.016 to .007,.010, rcur from .6615 to .6585
I should change the startup too, but leave it for now.

fizzle. Should have tweaked it.
got a normal breakdown time, slow current rise, never moves out.
now bz is negative and ramping up, br is positive again.

next shot: icef4 to -1305, br0 from .002 to .0017,pg4 to 21msec
Sep 11 2002 10:14:54:243AM1020911005Steve Wolfeshot 5: change to pre-program gas only, extend gas puff to 1.5sec
decrease clearin from .013,.016 to .007,.010, rcur from .6615 to .6585
icef4 to -1305, br0 from .002 to .0017,pg4 to 21msec

another dud! Fields went back where they were before, bz going positive,
br now slightly negative.

next shot: ic_ef4 to -1310, br0 back to .002, pg4 back to 24ms
Sep 11 2002 10:28:33:980AM1020911006Steve Wolfeshot 6: change to pre-program gas only, extend gas puff to 1.5sec
decrease clearin from .013,.016 to .007,.010, rcur from .6615 to .6585
ic_ef4 to -1310, br0 back to .002, pg4 back to 24ms

another dud. Go to ecdc.
Sep 11 2002 11:07:46:087AM1020911007Steve Wolfeshot 7: change to pre-program gas only, extend gas puff to 1.5sec
decrease clearin from .013,.016 to .007,.010, rcur from .6615 to .6585

plasma, got an h-mode. disrupted at 1.54 sec
has a growing vertical instability.
gets to 93kJ, with 1MW on axis and a short off-axis at 1 as well.

next shot: reduce the 1.5sec clearin point to .007, and ramp in from there.
move rxl in by .005 at 1.5sec
Sep 11 2002 11:19:56:973AM1020911008Steve Wolfeshot 8: reduce the 1.5sec clearin point to .007, and ramp in from there.
move rxl in by .005 at 1.5sec
ecdc for 5 minutes

fizz. Went at P=3e-6 instead of waiting for 2e-6.
breakdown is at 7.5ms. Br looks high. slow current rise.
Sep 11 2002 12:15:36:883PM1020911009Steve Wolfeshot 9: reduce the 1.5sec clearin point to .007, and ramp in from there.
move rxl in by .005 at 1.5sec
Br0 back to .0017

plasma disrupts at 1.54, just like shot 7.
No h-mode this time, density dropped to 4e-19 from 8 on shot 7,
with same gas puff! Feedback looks ok until the disruption.
Still getting this drop and loss of sawteeth around 1.25sec
I'm going to try turning tci feedback back on for next shot.
Sep 11 2002 12:32:47:657PM1020911010Steve Wolfeshot 10: tci feedback on, ecdc 5 minutes, drop pg4 to 22msec
init at 3.0e-6 pulse at 2.4e-6.

plasma to 1.87sec, no h-mode, tci worked.
No d, .5MW from E ragged, about 1.2 from J
50kJ in Lmode, then falling.

next shot: no ecdc
Sep 11 2002 12:40:55:300PM1020911011Steve Wolfeshot 11: no ecdc, pressure is still high 3.6e-6 in init
plasma to 1.87sec
breakdown is even later at 8.3msec
E at .9MW, no D or J, no H-mode
Sep 11 2002 12:53:18:877PM1020911012Steve Wolfeshot 12: no ecdc; p0=4.1e-6 at init.
plasma to 1.9sec. No h-modes. 1MW from D, no E or J

next shot: decrease outer gap by 5mm
Sep 11 2002 01:08:08:130PM1020911013Steve Wolfeshot 13: rcur from .6585 to .661

plasma to 1.8sec, tiny h-mode at 1.26sec
D and E ran separately 1.3 and 1.1MW respectively.
H-mode during E, which trips.
got the gap change ok, didn't seem to matter much to RF
Sep 11 2002 01:17:57:340PM1020911014Steve Wolfeshot 14: no changes.
dud. NO oh2's.

Sep 11 2002 01:38:16:790PM1020911015Steve Wolfeshot 15: no changes (except that oh2's went this time)
plasma to 1.9sec, no hmodes
another late breakdown, 8.5msec. As long as it runs, I'm not touching it.
D at 1.5MW, E at 1.4 separately, no J
H/D going from .23 to .33

Sep 11 2002 01:47:46:517PM1020911016Steve Wolfeshot 16: no changes
fizzle. Maybe time to tweak something.
bd at 7.5msec, actually earlier than it had been

next shot: decrease pg4 from 22ms to 20ms
Sep 11 2002 02:14:27:017PM1020911017Steve Wolfeshot 17: decrease pg4 from 22ms to 20ms
plasma to 1.73sec, no h-modes
D at 1.7, E at 1.5, no J.
breakdown still at 7.5ms

next shot: ramp tf down to 5.1T, starting at 1.1sec
Sep 11 2002 02:26:58:733PM1020911018Steve Wolfeshot 18: ramp tf down to 5.1T, starting at 1.1sec
early disruption .37sec, right at crossover.
wide1 video shows a projectile come out of the divertor, bounce off
the inner wall, go through the plasma again, kill it, and continue
up after the disruption.
Sep 11 2002 02:46:37:387PM1020911019Steve Wolfeshot 19: no changes, no ecdc. Give it a try.
plasma to 1.62sec, no h-mode.
D at 1.7MW E at 1.6

next shot: continue rampdown to 4.9T
Sep 11 2002 03:02:09:703PM1020911020Steve Wolfeshot 20: continue rampdown to 4.9T 138600ka
plasma to 1.61sec. I think I need to deal with the
rampdown again.
No h-modes. only got down to 5.0 T

next shot: drop tf faster.
Sep 11 2002 03:07:49:343PM1020911021Steve Wolfeshot 21: drop tf faster to get to 4.9
dud. presure was over 3e-6 at pulse.

try 5minutes of ecdc.
Sep 11 2002 03:42:56:470PM1020911022Steve Wolfeshot 22: drop tf faster to get to 4.9
5minutes of ecdc before shot

plasma - disrupts at same time. I need to do something to it,but I don't see
what's causing it. D&E both around 1.6MW, J up to 1.2 but faulting.

next shot: Hold tf at 145000, which is where the sawtooth amplitude
max's out on the sweep.

Sep 11 2002 03:54:13:387PM1020911023Steve Wolfeshot 23: tf to -145000, 5.15T (I think)
Didn't do anything about the rampdown; might be related to the tf sweep?

plasma to 1.63sec, not much different.
D 1.7, E 1.4, J nothing
Sep 11 2002 04:08:23:887PM1020911024Steve Wolfeshot 24: tweak rampdown clearin and rcur,slow down density drop
plasma to 1.93sec; no clue why this rampdown is better.
breakdown was late again 8.1msec

D&E at 1.6 to 1.7, J to 1.2 then faulting.
H/D goes from 0.2 to .37

next shot: NINJA will puff He in rampdown.
Sep 11 2002 04:17:20:377PM1020911025Steve Wolfeshot 25: NINJA will puff He in rampdown. No PCS changes.
dud.

take 5 minutes of ecdc before the next shot.
Sep 11 2002 04:43:27:657PM1020911026Steve Wolfeshot 26: plasma to 1.87sec
J is up to 1.3MW, D&E >1.5 each, running sequentially.
According to Yijun the J mode conversion layer is close to
the axis. The FRCECE is seeing very localized electron heating.
breakdown was late again, 8.7msec

next shot: No ecdc, no changes, see what happens.
Sep 11 2002 04:52:13:020PM1020911027Steve Wolfeshot 27: No ecdc, no changes, see what happens.
What happens is a dud. I think it's J, just like vacuum conditioning

ECDC for 5 minutes and try again. It's going to be a little after 5pm
Sep 11 2002 05:12:50:300PM1020911028Steve Wolfeshot 28: 5min of ecdc; started init at 4e-6

plasma to 1.61sec; rampdown still isn't fixed, I guess.
J at 1.3MW, still faulting, D or E (turned off intentionally)
D sees over 10kW of reverse power from J.
breakdown still late, 8.1msec

END OF RUN

Engineering Operator Comments
ShotTimeTypeStatusComment
109:09:13:017AMPlasmaOk
209:23:01:377AMPlasmaOk
309:36:00:093AMPlasmaOk
409:54:26:103AMPlasmaOk
510:07:31:273AMPlasmaOk
610:26:57:523AMPlasmaOk
710:53:43:397AMPlasmaOk
811:15:02:227AMPlasmaOk
911:57:03:340AMPlasmaOk
1012:20:05:173PMPlasmaOk
1112:34:26:270PMPlasmaOk
1212:47:24:737PMPlasmaOk
1301:01:42:880PMPlasmaOk
1401:14:57:300PMPlasmaBadboth Oh2's failed to run
1501:28:39:990PMPlasmaOk
1601:41:49:033PMPlasmaOk
1702:04:29:710PMPlasmaOk
1802:17:57:617PMPlasmaBadOH1 self powered ckt. fault, OH2 commutation fault
1902:34:07:873PMPlasmaOk
2002:50:35:287PMPlasmaOk
2103:04:28:663PMPlasmaOk
2203:26:41:900PMPlasmaOk
2303:44:44:927PMPlasmaOk
2403:59:04:507PMPlasmaOk
2504:13:02:430PMPlasmaOk
2604:33:25:587PMPlasmaOk
2704:47:06:320PMPlasmaOk
2805:04:16:440PMPlasmaOk