| H/D Mode Conversion Expt/Continue antenna conditioning; SL: Wukitch; PO: |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:30:477PM |
| Author: To Be Determined |
| Rf Conditioning Run 003 BT~5.4T, Ip~1.0 MA, nl04~0.9 D: 1.2 MW [1.2,1.5]sec E: 1.2 MW [1.0,1.3]sec J: 1.6 MW [0.6,1.0]sec result: plasma - TF fault due to programming error couple of H-modes - first one is with 70 MHz near the plasma edge D: 1.2 MW clean E: 1.2 MW clean J: 1.6 MW 3 faults 005 BT~4.6T, Ip~1.0 MA, nl04~0.9 D: 1.4 MW [1.2,1.5]sec E: 1.4 MW [1.0,1.3]sec J: 1.8 MW [0.6,1.0]sec result: plasma D: 1.4 MW E: 1.4 MW 6 faults (mostly with D on J: 1.8 MW max faults 007 BT~4.6T, Ip~1.0 MA, nl04~0.9 D: 1.4 MW [1.0,1.5]sec E: 1.4 MW [1.0,1.5]sec J: 1.8 MW [0.6,1.0]sec result: plasma D: 1.4 MW E: 1.4 MW 6 faults (mostly with D on) J: 1.8 MW max faults 008 BT~4.6T, Ip~0.8 MA, nl04~0.9 D: 1.4 MW [1.0,1.5]sec E: 1.4 MW [1.0,1.5]sec J: 1.8 MW [0.6,1.0]sec result: plasma D: 1.4 MW E: 1.4 MW max faults (all phase balance) J: 1.8 MW max faults raise phase balance on E to 160 kW 009 BT~4.6T, Ip~0.8 MA, nl04~0.9 D: 1.0 MW [1.0,1.5]sec E: 1.0 MW [1.0,1.5]sec J: 1.5 MW [0.6,1.0]sec result: plasma D: 1.0 MW clean E: 1.4 MW 2 faults J: 1.5 MW 8 faults improved with as pulse progressed 010 BT~4.6T, Ip~0.8 MA, nl04~0.9 D: 1.2 MW [1.0,1.5]sec E: 1.2 MW [1.0,1.5]sec J: 1.5 MW [0.6,1.0]sec result: plasma D: 1.2 MW clean E: 1.2 MW 2 faults J: 1.5 MW 8 faults improved with as pulse progressed 011 BT~4.6T, Ip~0.8 MA, nl04~0.9 D: 1.2 MW [1.0,1.5]sec E: 1.2 MW [1.0,1.5]sec J: 1.5 MW [0.6,1.0]sec result: plasma D: 1.2 MW clean E: 1.4 MW 5 faults J: 1.5 MW max faults 012 BT~4.6T, Ip~0.8 MA, nl04~1 D: 1.2 MW [1.0,1.5]sec E: 1.2 MW [1.0,1.5]sec J: 1.5 MW [0.6,1.0]sec result: plasma D: 1.2 MW clean E: 1.2 MW 8 faults J: 1.5 MW max faults 013 BT~4.6T, Ip~0.8 MA, nl04~1 D: 0.5 MW [1.0,1.5]sec E: 1.0 MW [1.0,1.5]sec J: 1.0 MW [0.6,1.0]sec result: plasma D: 0.5 MW clean E: 1.0 MW 7 faults J: 1.0 MW 1 fault 014 BT~4.6T, Ip~0.8 MA, nl04~1 D: 1.0 MW [1.3,1.5]sec E: 0.8 MW [.9,1.5]sec J: 1.2 MW [0.6,1.0]sec result: plasma D: 0.5 MW clean E: 0.8 MW 1 fault J: 1.2 MW 4 faults 015 BT~4.6T, Ip~0.8 MA, nl04~1 D: 1.0 MW [1.3,1.5]sec E: 0.9 MW [.9,1.5]sec J: 1.4 MW [0.6,1.5]sec result: plasma D: 1.0 MW clean E: 0.9 MW 2 faults J: 1.4 MW max faults 016 BT~4.6T, Ip~0.8 MA, nl04~1 D: 1.0 MW [1.3,1.5]sec E: 0.9 MW [0.9,1.5]sec J: 1.4 MW [0.6,1.5]sec result: plasma D: 1.0 MW max faults - phase balance E: 0.9 MW clean J: 1.4 MW max faults 017 BT~4.6T, Ip~0.8 MA, nl04~1 D: 1.0 MW [1.3,1.5]sec E: 1.1 MW [0.9,1.5]sec J: 1.4 MW [0.6,1.5]sec result: plasma D: 1.0 MW max faults E: 1.1 MW clean J: 1.6 MW max faults 018 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.0 MW [1.3,1.5]sec E: 1.1 MW [0.9,1.5]sec J: 1.4 MW [0.6,1.5]sec result: plasma D: 1.0 MW max faults E: 1.1 MW 3 faults J: 1.6 MW max faults 019 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.3 MW [1.3,1.5]sec E: 1.3 MW [0.9,1.5]sec J: 2.5 MW [0.6,1.5]sec result: plasma D: 1.3 MW clean E: 1.3 MW max faults J: 2.5 MW max faults 020 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.3 MW [1.3,1.5]sec E: 1.3 MW [0.9,1.5]sec J: 2.5 MW [0.6,1.5]sec result: plasma D: 1.3 MW clean E: 1.3 MW max faults J: 2.5 MW max faults 021 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.3 MW [1.3,1.5]sec E: 1.3 MW [0.9,1.5]sec J: 2.5 MW [0.6,1.5]sec result: plasma D: 1.3 MW clean E: 1.3 MW max faults J: 2.5 MW max faults better than previous 2.5 MW pulses 022 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.3 MW [1.3,1.5]sec E: 1.3 MW [0.9,1.5]sec J: 2.5 MW [0.6,1.5]sec result: plasma D: 1.3 MW clean E: 1.3 MW max faults J: 2.5 MW max faults 023 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.3 MW [1.3,1.5]sec E: 1.3 MW [0.9,1.5]sec J: 2.5 MW [0.6,1.5]sec result: plasma D: 1.3 MW clean E: 1.3 MW max faults J: 2.5 MW max faults 024 BT~4.5T, Ip~0.8 MA, nl04~1 D: 1.3 MW [1.3,1.5]sec E: 1.3 MW [0.9,1.5]sec J: 2.0 MW [0.6,1.5]sec result: plasma D: 1.3 MW clean E: 1.3 MW max faults J: 2.0 MW max faults Summary: D and E-port antennas ran well by themselves but had significant difficulty with simultaneous operation. J-port was slow in obtaining high power operation even when isolated. Antenna performance for all antennas is limited by coupled power that results in faulting. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:16:130PM |
| Author: To Be Determined |
| Physop summary for 1020916 SL Wukitch PO Mossessian Plan - RF conditionning Summary: Very good run from PO point of view. Just one fizzle at the beginning (shot 6) caused by too high gas pressure at startup. Then all plasmas. The rate of current rise was changing from shot to shot, but we were able to control it by small changes in the pre-puff length. Fields are stable. The toroidal field was changed from 5.4 T to 4.6 on shot 3, and then to 4.5 T on shot 18. 23 shots 3 tests 1 Fizzle 19 plasmas _________________________________________________________ 1020916001 Test ---------------------------------------------------------------------------- 1020916002 The second shot will be another test. ---------------------------------------------------------------------------- 1020916003 . . . . . . . . . . . . . . . . . . . Plasma. Startup is good, although the current rise may be a little slow. The TF was programed to ramp down from 6 to 5.4 T, (PO fault)), which it did. For next shot - PG4 to 29 ms , TF current to 129000 (for 4.6 T) ---------------------------------------------------------------------------- 1020916004 irby PHYSICS_OPERATOR Sep 16 2002 11:52:19:830AM . . . . . . . . . . . . . . . . . . . . This shot will be a 50 kA TF test. Nothing unusual was found to cause the TF crowbar. Looks good.... ---------------------------------------------------------------------------- 1020916005 irby PHYSICS_OPERATOR Sep 16 2002 12:26:47:180PM . . . . . . . . . . . . . . . . . . . . Plasma attempt Gas reduced to 29 ms TF current to 129 kA at 100 ms Plamsa into rampdown --- but did disrupt ---------------------------------------------------------------------------- 1020916006 mossessian PHYSICS_OPERATOR Sep 16 2002 12:23:17:130PM . . . . . . . . . . . . . . . . . . . . Fizzle. Too much gas Next shot - PG4 30 -> 25 ms ---------------------------------------------------------------------------- 1020916007 mossessian PHYSICS_OPERATOR Sep 16 2002 12:40:13:890PM . . . . . . . . . . . . . . . . . . . . Plasma. Disrupted at 1.56 right afer Ip/Bt strated ramping down. Next shot - PG4 -> 22 ms. Change Ip from 1 MA to 0.8 MA. ---------------------------------------------------------------------------- 1020916008 mossessian PHYSICS_OPERATOR Sep 16 2002 12:54:23:706PM . . . . . . . . . . . . . . . . . . . . Plasma. Very nice rampdown - went to t=1.98s, Ip=30 kA. I would say there is still too much gas at the beginning. Next shot - drop PG4 to 20 ms ---------------------------------------------------------------------------- 1020916009 mossessian PHYSICS_OPERATOR Sep 16 2002 1:05:29:570PM . . . . . . . . . . . . . . . . . . . . Plasma Next shot - no cahnges ---------------------------------------------------------------------------- 1020916010 mossessian PHYSICS_OPERATOR Sep 16 2002 1:22:55:876PM . . . . . . . . . . . . . . . . . . . . Plasma Next shot - no cahnges ---------------------------------------------------------------------------- 1020916011 mossessian PHYSICS_OPERATOR Sep 16 2002 1:35:37:396PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - nl 10% up to 9e19 ---------------------------------------------------------------------------- 1020916012 mossessian PHYSICS_OPERATOR Sep 16 2002 2:04:20:486PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no changes ---------------------------------------------------------------------------- 1020916013 mossessian PHYSICS_OPERATOR Sep 16 2002 2:23:41:766PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no changes ---------------------------------------------------------------------------- 1020916014 mossessian PHYSICS_OPERATOR Sep 16 2002 3:07:39:553PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - PG4 20 -> 23 ms. Ar pulse up 35 - > 45 ms ---------------------------------------------------------------------------- 1020916015 mossessian PHYSICS_OPERATOR Sep 16 2002 3:14:04:656PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no change ---------------------------------------------------------------------------- 1020916016 mossessian PHYSICS_OPERATOR Sep 16 2002 3:44:24:400PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no change ---------------------------------------------------------------------------- 1020916018 mossessian PHYSICS_OPERATOR Sep 16 2002 3:56:16:696PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no change ---------------------------------------------------------------------------- 1020916019 mossessian PHYSICS_OPERATOR Sep 16 2002 4:13:23:600PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no change ---------------------------------------------------------------------------- 1020916020 mossessian PHYSICS_OPERATOR Sep 16 2002 4:24:42:570PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - no change ---------------------------------------------------------------------------- 1020916022 mossessian PHYSICS_OPERATOR Sep 16 2002 4:53:31:833PM . . . . . . . . . . . . . . . . . . . . Plasma. Current rise too slow. Next shot - PG4 down to 21 ms ---------------------------------------------------------------------------- 1020916023 mossessian PHYSICS_OPERATOR Sep 16 2002 5:16:34:400PM . . . . . . . . . . . . . . . . . . . . Plasma. |
| Session Leader Comments |
| Physics Operator Comments | |||
| Sep 16 2002 07:58:18:940AM | Jim Irby | Did cold start rtnode -- data loaded, A matrix responds rtnode -- data loaded, M matrix responds rtnode -- data loaded, PID matrix responds RT_NODE Done 16-SEP-2002 07:57:21.66 doing TCL | |
| Sep 16 2002 09:53:11:930AM | 1020916001 | Jim Irby | Loaded -152 kA into TF seg 2 First shot will be a cycle test to check out alternator with excitation |
| Sep 16 2002 10:07:07:577AM | 1020916001 | Dmitri Mossessian | The plan for today is RF conditionning. We'll start with the last Thursday shot dropping the field down to 5.4 T Loaded 1020912025 (last good shot from Thursday), and changed the field to TF 152000 A |
| Sep 16 2002 10:08:22:640AM | 1020916002 | Dmitri Mossessian | The second shot will be another test. |
| Sep 16 2002 10:54:02:243AM | 1020916003 | Dmitri Mossessian | Plasma. Startup is good, although the current rise may be a little slow. The TF was programed to ramp down from 6 to 5.4 T, (PO fault)), which it did. For next shot - PG4 to 29 ms , TF current to 129000 (for 4.6 T) |
| Sep 16 2002 11:52:19:830AM | 1020916004 | Jim Irby | This shot will be a 50 kA TF test. Nothing unusual was found to cause the TF crowbar. Looks good.... |
| Sep 16 2002 12:18:36:077PM | 1020916005 | Dmitri Mossessian | Plasma. Current rise atstartup is a little low again. Next shot - no changes |
| Sep 16 2002 12:26:47:180PM | 1020916005 | Jim Irby | Plasma attempt Gas reduced to 29 ms TF current to 129 kA at 100 ms Plamsa into rampdown --- but did disrupt |
| Sep 16 2002 12:23:17:130PM | 1020916006 | Dmitri Mossessian | Fizzle. Too much gas Next shot - PG4 30 -> 25 ms |
| Sep 16 2002 12:40:13:890PM | 1020916007 | Dmitri Mossessian | Plasma. Disrupted at 1.56 right afer Ip/Bt strated ramping down. Next shot - PG4 -> 22 ms. Change Ip from 1 MA to 0.8 MA. |
| Sep 16 2002 12:54:23:707PM | 1020916008 | Dmitri Mossessian | Plasma. Very nice rampdown - went to t=1.98s, Ip=30 kA. I would say there si still too much gas at the beginning. Next shot - drop PG4 to 20 ms |
| Sep 16 2002 01:05:29:570PM | 1020916009 | Dmitri Mossessian | Plasma Next shot - no cahnges |
| Sep 16 2002 01:22:55:877PM | 1020916010 | Dmitri Mossessian | Plasma Next shot - no cahnges |
| Sep 16 2002 01:35:37:397PM | 1020916011 | Dmitri Mossessian | Plasma. Next shot - nl 10% up to 9e19 |
| Sep 16 2002 02:04:20:487PM | 1020916012 | Dmitri Mossessian | Plasma. Next shot - no changes |
| Sep 16 2002 02:23:41:767PM | 1020916013 | Dmitri Mossessian | Plasma. Next shot - no changes |
| Sep 16 2002 03:07:39:553PM | 1020916014 | Dmitri Mossessian | Plasma. Next shot - PG4 20 -> 23 ms. Ar pulse up 35 - > 45 ms |
| Sep 16 2002 03:14:04:657PM | 1020916015 | Dmitri Mossessian | Plasma. Next shot - no change |
| Sep 16 2002 03:44:24:400PM | 1020916016 | Dmitri Mossessian | Plasma. Next shot - no change |
| Sep 16 2002 03:56:16:697PM | 1020916018 | Dmitri Mossessian | Plasma. Next shot - no change |
| Sep 16 2002 04:13:23:600PM | 1020916019 | Dmitri Mossessian | Plasma. Next shot - no change |
| Sep 16 2002 04:24:42:570PM | 1020916020 | Dmitri Mossessian | Plasma. Next shot - no change |
| Sep 16 2002 04:53:31:833PM | 1020916022 | Dmitri Mossessian | Plasma. Current rise too slow. Next shot - PG4 down to 21 ms |
| Sep 16 2002 05:16:34:400PM | 1020916023 | Dmitri Mossessian | Plasma. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:58:07:483AM | Test | Ok | ALternator Excitation Test |
| 2 | 10:21:30:037AM | Test | Ok | Alternator Excitation and Breaker Test |
| 3 | 10:42:00:800AM | Plasma | Bad | TF Crowbar |
| 4 | 11:49:42:890AM | Test | Ok | TF 50KA Test , |
| 5 | 12:04:32:227PM | Plasma | Ok | |
| 6 | 12:17:52:137PM | Plasma | Ok | |
| 7 | 12:30:40:670PM | Plasma | Ok | |
| 8 | 12:48:53:170PM | Plasma | Ok | |
| 9 | 01:02:07:813PM | Plasma | Ok | |
| 10 | 01:14:54:410PM | Plasma | Ok | |
| 11 | 01:31:38:030PM | Plasma | Ok | |
| 12 | 01:59:28:060PM | Plasma | Ok | |
| 13 | 02:14:39:003PM | Plasma | Ok | |
| 14 | 02:35:21:333PM | Plasma | Ok | |
| 15 | 03:09:10:807PM | Plasma | Ok | |
| 16 | 03:26:09:730PM | Plasma | Ok | |
| 17 | 03:40:28:830PM | Plasma | Ok | |
| 18 | 03:53:32:177PM | Plasma | Ok | |
| 19 | 04:08:10:463PM | Plasma | Ok | |
| 20 | 04:22:26:113PM | Plasma | Ok | |
| 21 | 04:35:38:663PM | Plasma | Ok | |
| 22 | 04:50:12:750PM | Plasma | Ok | |
| 23 | 05:03:13:253PM | Plasma | Ok | |