Alcator C-Mod Run 1021016 Information

Back to runs

Miniproposals
Miniproposal:312
Date Filed: 6/14/2002
Title:Ohmic H - modes
First Author: Lee
Session Leader: Lee (shots 1-32)

Operators
Session leader(s): Lee
Physics operator(s):Steve Wolfe,Jim Irby
Engineering operator(s):Ed Fitzgerald,Bill Cochran

Engineering Operator Run Comment
MP #312 ITB Toridal Rotation Ohmic H-Mode. Lee/Irby/Wolfe/Cochran

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:31:337PM
Author: To Be Determined
Run Sumary for 16 October 2002 (1021016)

Mini Proposal #312: Ohmic H-Modes

The purpose of this experiment is to investigate the shape of the
rotation profile for Ohmic H-modes. There are two reasons for this
experiment. First, for use as a comparison to ICRF
H-modes. Second, to determine the shape of the profile with an eye on
the transport mechanism. This investigation would be part of a larger set of data
pertaining to Ohmic H-mode, ICRF H-mode, and plasma rotation.



Shot 001
Cycle test

Loaded shot: 1020815029

Shot 002
Plasma:
disruption ~1.6 sec, No H-Mode, low but acceptable signal on all spectrometers

Shot 003
Plasma
disruption ~1.6 sec, H-Modes
Signal is low, K-port tripped, f is low but acceptable, jr. looks fine

Shot 004
Plasma
disruption ~1.6 sec, H-Modes
10 ms Ar puff, limited signal, line fits not run.

Shot 005
NOT Plasma

Shot 006
Plasma
disruption ~1.6 sec, H-Mode
Signal is low, a few time slice are o.k, but the count rate is low

Shot 007
Plasma
disruption ~1.5 sec, H-Mode ~0.7
Signal is o.k, Count rate is o.k. all spectrometers have decent signal

Shot 008
Plasma
disruption ~1.5 sec, H-Mode ~0.64
Signal is o.k, Count rate is o.k. all spectrometers have decent signal
Ar up to 40 ms

Shot 009
Plasma
disruption ~1.55 sec, H-Mode ~0.61
Signal is o.k, Count rate is o.k. all spectrometers have decent signal

>>>> We now switch, and preload 1020926026

Shot 010
we have switched the preloaded shot to 1020926026
Plasma
No Ar puff

Shot 011
No Ar puff

Shot 012
Ar!
Plasma! H-Mode!
This looks good, all spectrometers.

Shot 013
Looks great!
all spectrometers have good signal.

Shot 014
fizzle

Shot 015
Plasma looks good,
H-mode, very repeatably at 0.8945 sec,
data from all spectrometers looks good!

Shot 016
I changed the timing on F & K port spectrometers during this shot so they would collect every 20 ms, as opposed to every 50 ms. I also shifted their offset to 0.6 so that they run from 0.6 to 1.24 sec. this should help with the rise time measurements.

changed the HIREX 3 & 5 sampling rate to 50 Hz, the time offset is 0.6
this will make 3 & 5 collect from 0.6 to 1.24 sec.

Plasma looks good,
H-mode, at 0.9052 sec,
data from all spectrometers looks fairly good.

Shot 017
Plasma looks good,
H-mode, at 0.8981 sec,
data from all spectrometers looks fairly good.
strange rotation profile though.


Shot 018
Plasma looks good,
H-mode, at 0.8981 sec,
data from all spectrometers looks fairly good.
strange rotation profile though.

Shot 019
Plasma looks good,
H-mode, at 0.8873 sec,
data from all spectrometers looks fairly good.
still strange rotation profile though.

Shot 020
Plasma looks good,
H-mode, at 0.910 sec, shorter duration
data from all spectrometers looks o.k. count rates are not the best

Shot 021
Plasma looks good,
H-mode, at 0.914 sec
data from all spectrometers looks o.k.
rotation is still dropping in the center and staying up outside

Shot 022
Plasma looks good,
H-mode, at 0.8638 sec
data from all spectrometers looks o.k.
rotation is still dropping in the center and staying up outside

Shot 023
Plasma looks good,
H-mode, at 0.9069 sec
Jr. triped, others look o.k.

024
Plasma looks good,
H-mode, at 0.8961 sec
I think I have figured out why the rotation was so weird
I think it was a timing problem, wtih the camac.
I may have corrected it.

025
Plasma looks good,
H-mode, at 0.9123 sec
count rates were o.k.

026
Fizzle

027
Plasma looks good,
H-mode, at 0.9213 sec
count rates were o.k.

028
Plasma looks good,
H-mode, at 0.8961 sec
count rates were o.k. Signals look good.

029
Plasma looks good,
H-mode, at 0.9033 sec
count rates were very good. Signals look good.

030
Fizzle

031
Plasma looks good,
H-mode, at 0.9105 sec
count rates were very good. Signals look good.

032
Plasma looks good,
H-mode, at 0.8961 sec
count rates were very good. Signals look good.

More analysis will be required to determine if we have all the data that we need, but this run was very useful in fulfilling the goals of MP #312.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:16:550PM
Author: To Be Determined
Physop Summary for Wednesday, October 16th, Run 1021016

MP#312 ITB Toroidal Rotation Ohmic H-Mode

SL: Lee
EO:Cochran, Fitzgerald
PO: Irby/Wolfe

ECDC overnight in D2 stopping by 07:00.
Overnight bake at 60C

Set up for possible ECDC in D2 between shots.

Engineering setup as on 1020815029

Power systems the same as shot 1020822010 Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
fill B-side upper with 10 psi D2 Hybrid DISABLED (PG2) (for ECDC)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

J-Bottom should be disabled and pumped out

Enable the following gate valves: ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: NO RF Required for this run
-------------------------------------------------------------------------------

Primary goal for the ill be to produce reproducible discharges so
that SL can get good statistics.

-------------------------------------------------------------------------------
Summary
-------------------------------------------------------------------------------

Startup was very good today in spite of the problems we had getting a
clean current rise. I believe we provided good data for the rotation
studies. Steve Wolfe suggested we reload shot 1020926026 early in the
run rather than continue incrementing from shot 1020815029. This
change produced a very reliable h-mode plasma. These shots also
lasted well into rampdown, unlike those from 08/15.

On shot 5 we managed to store away parts of shot 4, plus have a very
confused initialization process resulting in a dud.

Duds
Fizzles 14,26,30 03
Plasmas 02,03,04,06,07,08,09,10,11,12,13,15,16 28
17,18,19,20,21,22,23,24,25,27,28,29,31,32
Faults 05 01
Tests 01 01
--
32 cycles

-------------------------------------------------------------------------------
1021016xxx irby DISCHARGE_CLEAN Oct 16 2002 7:45:00:243AM
. . . . . . . . . . . . . . . . . . . .
ECDC was run from last Friday evening until this morning at 2e-4 Torr D2.
The vessel temperature was maintained at 60C during most of this time.
----------------------------------------------------------------------------
1021016001 irby PHYSICS_OPERATOR Oct 16 2002 9:09:26:180AM
. . . . . . . . . . . . . . . . . . . .
Loaded seg 3 from 1020815029 into segment 2: Yes, seg 2 is on

Pulsed Gas 1 (Argon) from 0.350 to 0.385 s (35 ms)

This shot will actually be a data system cycle/gas puff test --- data okay, pressure okay, IGOR hung for a while
----------------------------------------------------------------------------
1021016002 irby PHYSICS_OPERATOR Oct 16 2002 9:33:23:196AM
. . . . . . . . . . . . . . . . . . . .
Try for plasma

Lost plasma at 1.57 s: No h-mode

target density a little low compared to 08/15 shot

h/(h+d) at 2%

----------------------------------------------------------------------------
1021016003 irby PHYSICS_OPERATOR Oct 16 2002 9:59:56:010AM
. . . . . . . . . . . . . . . . . . . .
Raised nl04 request from .8e20/m^2 to 9e20/m^2

EF4 to -1315 from -1325 A ---- a feel good tweak to fix very low Bz0 that will probably
jump positive on its own this shot

Plasma into rampdown --- EF4 somewhat more positive --- 2 h-modes

----------------------------------------------------------------------------
1021016004 irby PHYSICS_OPERATOR Oct 16 2002 10:12:28:853AM
. . . . . . . . . . . . . . . . . . . .
Increase prop gain on nl04 from 6 to 7 at 100 ms

Cut argon puff in half for one shot to see effect

Plasma fpr 1.58 s --- still disrupting?

H-modes

nl04 gain increase helped early density
----------------------------------------------------------------------------
1021016005 irby PHYSICS_OPERATOR Oct 16 2002 10:42:54:696AM
. . . . . . . . . . . . . . . . . . . .
Argon puff back to 35 ms
NL04 gain to 7 at .05 s

no plasma

Data system very messed up. Looks like mixture of shot 4 and 5
----------------------------------------------------------------------------
1021016006 irby PHYSICS_OPERATOR Oct 16 2002 11:04:05:556AM
. . . . . . . . . . . . . . . . . . . .
Another attempt at shot 5

Before this shot the TCI laser was re-locked fixing problem with edge channels

Plasma with one h-mode

Will try to tweak rampdown on for shot 7
----------------------------------------------------------------------------
1021016007 irby PHYSICS_OPERATOR Oct 16 2002 11:27:15:633AM
. . . . . . . . . . . . . . . . . . . .
Started Ip rampdown at 1.3 s
Plasma -- 2 h-modes
----------------------------------------------------------------------------
1021016008 irby PHYSICS_OPERATOR Oct 16 2002 11:31:32:773AM
. . . . . . . . . . . . . . . . . . . .
Increased argon puff to 40 ms
Ramping Ip down a little more strongly

One h-mode

Rampdown is actually worse --- will go back to shot 4 programming next shot

Time (ms): 0 5 10 25
----------------------------------------
Ip (kA): -4.0205 -15.7299 -30.0858 -74.0807
dIp/dt (kA/ms): -1.3085 -2.5874 -1.8236 -6.1353
Bz0 (mT): -4.9634 -2.9280 -1.4814 16.9785
Br0 (mT): -0.6554 -0.9316 -1.3487 -0.8695
----------------------------------------------------------------------------
1021016009 irby PHYSICS_OPERATOR Oct 16 2002 11:54:28:620AM
. . . . . . . . . . . . . . . . . . . .
Delayed Ip rampdown to 1.5 s
Delayed TF rampdown to 1.5 s

Plasma till 1.54 s --- 2 h-modes

Still disrupting
----------------------------------------------------------------------------
1021016010 irby PHYSICS_OPERATOR Oct 16 2002 12:22:40:633PM
. . . . . . . . . . . . . . . . . . . .
Loaded seg 2 from 1020926026 --- another/better ohmic h-mode day

Plasma to 1.7 s, but no h-mode ---- operator forgot to load shot 26!
----------------------------------------------------------------------------
1021016011 irby PHYSICS_OPERATOR Oct 16 2002 12:29:21:870PM
. . . . . . . . . . . . . . . . . . . .
In fact loaded 1020926026 for this shot
No Argon

Nice H-mode with ITB



----------------------------------------------------------------------------
1021016012 irby PHYSICS_OPERATOR Oct 16 2002 12:53:33:133PM
. . . . . . . . . . . . . . . . . . . .
Repeat but with 35 ms of Argon

Plasma into rampdown --- good h-modes
----------------------------------------------------------------------------
1021016013 irby PHYSICS_OPERATOR Oct 16 2002 12:54:48:523PM
. . . . . . . . . . . . . . . . . . . .
Plasma into rampdown --- SL is very happy
----------------------------------------------------------------------------
1021016014 irby PHYSICS_OPERATOR Oct 16 2002 1:02:11:790PM
. . . . . . . . . . . . . . . . . . . .
Added a little gas early to damp run-aways.

Fizzle --- gas too high --- didn't notice trend


----------------------------------------------------------------------------
1021016015 irby PHYSICS_OPERATOR Oct 16 2002 1:32:07:680PM
. . . . . . . . . . . . . . . . . . . .
Reduced gas by 1 ms ---- not clear which way we should really go comparing radial position
change to ratiomatic trend --- so don't do much...

Nice plasma -- good h-mode for Davis

----------------------------------------------------------------------------
1021016016 irby PHYSICS_OPERATOR Oct 16 2002 1:32:27:930PM
. . . . . . . . . . . . . . . . . . . .
Repeat

Good plasma
----------------------------------------------------------------------------
1021016017 irby PHYSICS_OPERATOR Oct 16 2002 4:26:42:186PM
. . . . . . . . . . . . . . . . . . . .
Added 2 ms to prepuff: now 30 ms

----------------------------------------------------------------------------
1021016018 wolfe PHYSICS_OPERATOR Oct 16 2002 1:53:43:963PM
. . . . . . . . . . . . . . . . . . . .
shot#18: wolfe taking over for Irby while he goes to a meeting
No changes (although I think the gas is too low)
Note Btop plenum pressure is only reading 5.5psi, instead of usual 6.5

plasma, disrupted at 1.51, seems to have hmode and barrier.
Davis thinks the barrier may be narrower than usual
Runaways early again.

next shot: increase pg4
----------------------------------------------------------------------------
1021016019 wolfe PHYSICS_OPERATOR Oct 16 2002 2:08:01:070PM
. . . . . . . . . . . . . . . . . . . .
shot#19: increase pg4 from 29 to 32msec

plasma, full length, hmode still there,
no bounce this time. Rather long hesitation in current rise.
next shot: down 1ms on pg4
----------------------------------------------------------------------------
1021016020 wolfe PHYSICS_OPERATOR Oct 16 2002 2:22:22:140PM
. . . . . . . . . . . . . . . . . . . .
shot#20: pg4 from 32 to 31msec

plasma, full length. Hmode was shorter this time.
Doesn't look like it got an ITB?
slight early bounce. Leave it alone until it gets worse.
----------------------------------------------------------------------------
1021016021 wolfe PHYSICS_OPERATOR Oct 16 2002 2:33:04:483PM
. . . . . . . . . . . . . . . . . . . .
shot#21: No pcs changes
plasma full length; hmode looks better.
I think the previous one got killed by a random injection.

next shot: no changes
----------------------------------------------------------------------------
1021016022 wolfe PHYSICS_OPERATOR Oct 16 2002 2:53:05:593PM
. . . . . . . . . . . . . . . . . . . .
shot#22: No pcs changes
long delay for data system problem on shot 21, some analysis jobs lost

plasma, hmode; may have had an early injection.
current rise looks fast, then turns around but survives.
I'm resisting the temptation to raise the pre-puff again.

next shot: No changes
----------------------------------------------------------------------------
1021016023 wolfe PHYSICS_OPERATOR Oct 16 2002 3:11:12:916PM
. . . . . . . . . . . . . . . . . . . .
shot#23: No pcs changes

plasma, full length, hmode ok
still bouncing in current rise.

next shot: No changes
----------------------------------------------------------------------------
1021016023 wolfe PHYSICS_OPERATOR Oct 16 2002 3:15:19:440PM
. . . . . . . . . . . . . . . . . . . .
shot#23: I started to change the drawn waveform for RCUR and PCS
recalculated the predictors! I reloaded the old wire and tried to edit
screen, and it complains predictors are invalid! I suspect somebody
loaded an old startup and didn't update the predictors.

I can re-do it now, keeping the offset of 3600, but I don't know what it will do.
----------------------------------------------------------------------------
1021016024 wolfe PHYSICS_OPERATOR Oct 16 2002 3:22:54:340PM
. . . . . . . . . . . . . . . . . . . .
shot#24: no changes

plasma hmode ok.

next shot: Recalculate the rcur and zcur predictors in seg1.
----------------------------------------------------------------------------
1021016025 wolfe PHYSICS_OPERATOR Oct 16 2002 3:34:01:966PM
. . . . . . . . . . . . . . . . . . . .
shot#25: Recalculate the rcur and zcur predictors in seg1 to get rid of "invalid predictor"
leave Rcur waveform and offset=3600, just see if startup changes.

plasma, disrupts at 1.71.
startup looks very similar, a little less turnaround but still bouncy.
I thought that the difference would show up in PCS::P_01:PREDICTOR:INPUTS
but that seems not to have changed. I don't get it.

next shot: no changes, while I puzzle this out.
----------------------------------------------------------------------------
1021016025 wolfe PHYSICS_OPERATOR Oct 16 2002 3:37:12:910PM
. . . . . . . . . . . . . . . . . . . .
shot#25: It looks like I didn't actually do the recalculation on RCUR?
Do it for next shot, and load it!
----------------------------------------------------------------------------
1021016026 wolfe PHYSICS_OPERATOR Oct 16 2002 3:46:26:190PM
. . . . . . . . . . . . . . . . . . . .
shot#26: Recalculate rcur pred in seg1.
fizzle! I probably killed it.

Current gets to 55kA, bz swings way negative
I bet I forgot to put back the offset!

next shot: rcur offset in seg1 back to 3600
----------------------------------------------------------------------------
1021016027 wolfe PHYSICS_OPERATOR Oct 16 2002 3:58:02:426PM
. . . . . . . . . . . . . . . . . . . .
shot#27: rcur offset in seg1 back to 3600, where it was before.

plasma, looks ok
startup has a big turnaround, almost lost it on this bounce.
The current rise is really fast, gets to 50kA at 12msec.

next shot: pg4 up to 33msec
----------------------------------------------------------------------------
1021016028 wolfe PHYSICS_OPERATOR Oct 16 2002 4:10:24:163PM
. . . . . . . . . . . . . . . . . . . .
shot#28:pg4 from 31 to 33msec

plasma, ok.

Irby is back. I'll keep trying to figure out why PCS thought
the seg1 rcur was invalid offline.
----------------------------------------------------------------------------
1021016029 irby PHYSICS_OPERATOR Oct 16 2002 4:34:07:133PM
. . . . . . . . . . . . . . . . . . . .
Cell access for Ron Bravenec to remove polarizers (via Howard) following shot.

Good plasma

----------------------------------------------------------------------------
1021016030 irby PHYSICS_OPERATOR Oct 16 2002 4:45:40:700PM
. . . . . . . . . . . . . . . . . . . .
Reduced prepuff by 2ms ----

Fizzle!
----------------------------------------------------------------------------
1021016031 irby PHYSICS_OPERATOR Oct 16 2002 4:59:52:080PM
. . . . . . . . . . . . . . . . . . . .
Increased prepuff by 3 ms (Steve's change plus 1)

plasma into rampdown
----------------------------------------------------------------------------
1021016032 irby PHYSICS_OPERATOR Oct 16 2002 5:23:49:696PM
. . . . . . . . . . . . . . . . . . . .
Added 1 ms to prepuff (35 ms total)

Plasma into rampdown --- startup a little better










Session Leader Comments
Oct 16 2002 08:52:26:557AM1021016001 This was a cycle test
Oct 16 2002 09:21:32:603AM1021016002 Plasma
disruption ~1.6 sec, No H-Mode, low but acceptable signal on all spectrometers

Oct 16 2002 09:50:27:603AM1021016003 Plasma
disruption ~1.6 sec, H-Modes
Signal is low, K-port tripped, f is low but acceptable, jr. looks fine

Oct 16 2002 10:10:41:587AM1021016004 Plasma
disruption ~1.6 sec, H-Modes
10 ms Ar puff, limited signal, line fits not run.
Oct 16 2002 10:28:09:790AM1021016005 NOT Plasma
Oct 16 2002 10:56:21:540AM1021016006 Plasma
disruption ~1.6 sec, H-Mode
Signal is low, a few time slice are o.k, but the count rate is low
Oct 16 2002 11:24:12:573AM1021016007 Plasma
disruption ~1.5 sec, H-Mode ~0.7
Signal is o.k, Count rate is o.k. all spectrometers have decent signal
Oct 16 2002 11:38:35:540AM1021016008

Plasma
disruption ~1.5 sec, H-Mode ~0.64
Signal is o.k, Count rate is o.k. all spectrometers have decent signal
Ar up to 40 ms
Oct 16 2002 11:54:49:493AM1021016009 Plasma
disruption ~1.55 sec, H-Mode ~0.61
Signal is o.k, Count rate is o.k. all spectrometers have decent signal
Oct 16 2002 12:05:51:120PM1021016010 we have switched the preloaded shot to 1020926026
Plasma
No Ar puff
Oct 16 2002 12:41:41:760PM1021016011 No Ar
Oct 16 2002 12:45:29:650PM1021016012 Ar!
Plasma! H-Mode!
This looks good, all spectrometers.
Oct 16 2002 12:48:49:230PM1021016013 Looks great!
all spectrometers have good signal.
Oct 16 2002 01:17:01:447PM1021016015 Plasma looks good,
H-mode, very repeatably at 0.8945 sec,
data from all spectrometers looks good!

I am a happy camper.
Oct 16 2002 01:37:16:353PM1021016016 changed the HIREX 3 & 5 sampling rate to 50 Hz, the time offset is 0.6
this will make 3 & 5 collect from 0.6 to 1.24 sec.

Plasma looks good,
H-mode, at 0.9052 sec,
data from all spectrometers looks fairly good.
Oct 16 2002 01:53:47:977PM1021016017 Plasma looks good,
H-mode, at 0.8981 sec,
data from all spectrometers looks fairly good.
strange rotation profile though.
Oct 16 2002 02:13:36:267PM1021016018 Plasma looks good,
H-mode, at 0.8981 sec,
data from all spectrometers looks fairly good.
strange rotation profile though.
Oct 16 2002 02:15:55:690PM1021016019 Plasma looks good,
H-mode, at 0.8873 sec,
data from all spectrometers looks fairly good.
still strange rotation profile though.
Oct 16 2002 02:24:22:313PM1021016020 Plasma looks good,
H-mode, at 0.910 sec, shorter duration
data from all spectrometers looks o.k. count rates are not the best

Oct 16 2002 02:42:16:873PM1021016021 Plasma looks good,
H-mode, at 0.914 sec
data from all spectrometers looks o.k.
rotation is still dropping in the center and staying up outside

Oct 16 2002 03:04:29:407PM1021016022 Plasma looks good,
H-mode, at 0.8638 sec
data from all spectrometers looks o.k.
rotation is still dropping in the center and staying up outside

Oct 16 2002 03:10:17:993PM1021016023 Plasma looks good,
H-mode, at 0.9069 sec
Jr. triped, others look o.k.


Oct 16 2002 03:47:58:503PM1021016024 Plasma looks good,
H-mode, at 0.8961 sec
I think I have figured out why the rotation was so weird
I think it was a timing problem, wtih the camac.
I may have corrected it.



Oct 16 2002 03:55:49:517PM1021016025 Plasma looks good,
H-mode, at 0.9123 sec
count rates were o.k.



Oct 16 2002 03:57:28:580PM1021016026 fizzle
Oct 16 2002 04:01:16:290PM1021016027 Plasma looks good,
H-mode, at 0.9213 sec
count rates were o.k.

Oct 16 2002 04:11:19:807PM1021016028 Plasma looks good,
H-mode, at 0.8961 sec
count rates were o.k. Signals look good.


Oct 16 2002 04:30:59:457PM1021016029 Plasma looks good,
H-mode, at 0.9033 sec
count rates were very good. Signals look good.


Oct 16 2002 04:52:44:663PM1021016030 Fizzle
Oct 16 2002 05:01:59:083PM1021016031 Plasma looks good,
H-mode, at 0.9105 sec
count rates were very good. Signals look good.

Oct 16 2002 05:09:38:407PM1021016032 Plasma looks good,
H-mode, at 0.8961 sec
count rates were very good. Signals look good.

Physics Operator Comments
Oct 16 2002 09:09:26:180AM1021016001Jim IrbyLoaded seg 3 from 1020815029 into segment 2: Yes, seg 2 is on

Pulsed Gas 1 (Argon) from 0.350 to 0.385 s (35 ms)

This shot will actually be a data system cycle/gas puff test --- data okay, pressure okay, IGOR hung for a while
Oct 16 2002 09:33:23:197AM1021016002Jim IrbyTry for plasma

Lost plasma at 1.57 s: No h-mode

target density a little low compared to 08/15 shot

h/(h+d) at 2%

Oct 16 2002 09:59:56:010AM1021016003Jim IrbyRaised nl04 request from .8e20/m^2 to 9e20/m^2

EF4 to -1315 from -1325 A ---- a feel good tweak to fix very low Bz0 that will probably
jump positive on its own this shot

Plasma into rampdown --- EF4 somewhat more positive --- 2 h-modes

Oct 16 2002 10:12:28:853AM1021016004Jim IrbyIncrease prop gain on nl04 from 6 to 7 at 100 ms

Cut argon puff in half for one shot to see effect

Plasma fpr 1.58 s --- still disrupting?

H-modes

nl04 gain increase helped early density
Oct 16 2002 10:42:54:697AM1021016005Jim IrbyArgon puff back to 35 ms
NL04 gain to 7 at .05 s

no plasma

Data system very messed up. Looks like mixture of shot 4 and 5
Oct 16 2002 11:04:05:557AM1021016006Jim IrbyAnother attempt at shot 5

Before this shot the TCI laser was re-locked fixing problem with edge channels

Plasma with one h-mode

Will try to tweak rampdown on for shot 7
Oct 16 2002 11:27:15:633AM1021016007Jim IrbyStarted Ip rampdown at 1.3 s
Plasma -- 2 h-modes
Oct 16 2002 11:31:32:773AM1021016008Jim IrbyIncreased argon puff to 40 ms
Ramping Ip down a little more strongly

One h-mode

Rampdown is actually worse --- will go back to shot 4 programming next shot

Time (ms): 0 5 10 25
----------------------------------------
Ip (kA): -4.0205 -15.7299 -30.0858 -74.0807
dIp/dt (kA/ms): -1.3085 -2.5874 -1.8236 -6.1353
Bz0 (mT): -4.9634 -2.9280 -1.4814 16.9785
Br0 (mT): -0.6554 -0.9316 -1.3487 -0.8695
Oct 16 2002 11:54:28:620AM1021016009Jim IrbyDelayed Ip rampdown to 1.5 s
Delayed TF rampdown to 1.5 s

Plasma till 1.54 s --- 2 h-modes

Still distrupting
Oct 16 2002 12:22:40:633PM1021016010Jim IrbyLoaded seg 2 from 1020926026 --- another/better ohmic h-mode day

Plasma to 1.7 s, but no h-mode ---- operator forgot to load shot 26!
Oct 16 2002 12:29:21:870PM1021016011Jim IrbyIn fact loaded 1020926026 for this shot
No Argon

Nice H-mode with ITB



Oct 16 2002 12:53:33:133PM1021016012Jim IrbyRepeat but with 35 ms of Argon

Plasma into rampdown --- good h-modes
Oct 16 2002 12:54:48:523PM1021016013Jim IrbyPlasma into rampdown --- SL is very happy
Oct 16 2002 01:02:11:790PM1021016014Jim IrbyAdded a little gas early to damp run-aways.

Fizzle --- gas too high --- didn't notice trend


Oct 16 2002 01:32:07:680PM1021016015Jim IrbyReduced gas by 1 ms ---- not clear which way we should really go comparing radial position
change to ratiomatic trend --- so don't do much...

Nice plasma -- good h-mode for Davis

Oct 16 2002 01:32:27:930PM1021016016Jim IrbyRepeat

Good plasma
Oct 16 2002 04:26:42:187PM1021016017Jim IrbyAdded 2 ms to prepuff: now 30 ms

Oct 16 2002 01:53:43:963PM1021016018Steve Wolfeshot#18: wolfe taking over for Irby while he goes to a meeting
No changes (although I think the gas is too low)
Note Btop plenum pressure is only reading 5.5psi, instead of usual 6.5

plasma, disrupted at 1.51, seems to have hmode and barrier.
Davis thinks the barrier may be narrower than usual
Runaways early again.

next shot: increasse pg4
Oct 16 2002 02:08:01:070PM1021016019Steve Wolfeshot#19: increasse pg4 from 29 to 32msec

plasma, full length, hmode still there,
no bounce this time. Rather long hesitation in current rise.
next shot: down 1ms on pg4
Oct 16 2002 02:22:22:140PM1021016020Steve Wolfeshot#20: pg4 from 32 to 31msec

plasma, full length. Hmode was shorter this time.
Doesn't look like it got an ITB?
slight early bounce. Leave it alone until it gets worse.
Oct 16 2002 02:33:04:483PM1021016021Steve Wolfeshot#21: No pcs changes
plasma full length; hmode looks better.
I think the previous one got killed by a random injection.

next shot: no changes
Oct 16 2002 02:53:05:593PM1021016022Steve Wolfeshot#22: No pcs changes
long delay for data system problem on shot 21, some analysis jobs lost

plasma, hmode; may have had an early injection.
current rise looks fast, then turns around but survives.
I'm resisting the temptation to raise the pre-puff again.

next shot: No changes
Oct 16 2002 03:11:12:917PM1021016023Steve Wolfeshot#23: No pcs changes

plasma, full length, hmode ok
still bouncing in current rise.

next shot: No changes
Oct 16 2002 03:15:19:440PM1021016023Steve Wolfeshot#23: I started to change the drawn waveform for RCUR and PCS
recalculated the predictors! I reloaded the old wire and tried to edit
screen, and it complains predictors are invalid! I suspect somebody
loaded an old startup and didn't update the predictors.

I can re-do it now, keeping the offset of 3600, but I don't know what it will do.
Oct 16 2002 03:22:54:340PM1021016024Steve Wolfeshot#24: no changes

plasma hmode ok.

next shot: Recalculate the rcur and zcur predictors in seg1.
Oct 16 2002 03:34:01:967PM1021016025Steve Wolfeshot#25: Recalculate the rcur and zcur predictors in seg1 to get rid of "invalid predictor"
leave Rcur waveform and offset=3600, just see if startup changes.

plasma, disrupts at 1.71.
startup looks very similar, a little less turnaround but still bouncy.
I thought that the difference would show up in PCS::P_01:PREDICTOR:INPUTS
but that seems not to have changed. I don't get it.

next shot: no changes, while I puzzle this out.
Oct 16 2002 03:37:12:910PM1021016025Steve Wolfeshot#25: It looks like I didn't actually do the recalculation on RCUR?
Do it for next shot, and load it!
Oct 16 2002 03:46:26:190PM1021016026Steve Wolfeshot#26: Recalculate rcur pred in seg1.
fizzle! I probably killed it.

Current gets to 55kA, bz swings way negative
I bet I forgot to put back the offset!

next shot: rcur offset in seg1 back to 3600
Oct 16 2002 03:58:02:427PM1021016027Steve Wolfeshot#27: rcur offset in seg1 back to 3600, where it was before.

plasma, looks ok
startup has a big turnaround, almost lost it on this bounce.
The current rise is really fast, gets to 50kA at 12msec.

next shot: pg4 up to 33msec
Oct 16 2002 04:10:24:163PM1021016028Steve Wolfeshot#28:pg4 from 31 to 33msec

plasma, ok.

Irby is back. I'll keep trying to figure out why PCS thought
the seg1 rcur was invalid offline.
Oct 16 2002 04:34:07:133PM1021016029Jim IrbyCell access for Ron Bravenec to remove polarizers (via Howard) following shot.

Good plasma

Oct 16 2002 04:45:40:700PM1021016030Jim IrbyReduced prepuff by 2ms ----

Fizzle!
Oct 16 2002 04:59:52:080PM1021016031Jim IrbyIncreased prepuff by 3 ms (Steve's change plus 1)

plasma into rampdown
Oct 16 2002 05:23:49:697PM1021016032Jim IrbyAdded 1 ms to prepuff (35 ms total)

Plasma into rampdown --- startup a little better

Engineering Operator Comments
ShotTimeTypeStatusComment
108:50:32:743AMTestOkCycle/Gas Test
209:09:19:727AMPlasmaOk
309:38:00:277AMPlasmaOk
409:59:42:353AMPlasmaOk
510:14:18:073AMPlasmaBadCamac System Fault
610:43:35:980AMPlasmaOk
711:09:34:120AMPlasmaOk
811:26:14:277AMPlasmaOk
911:40:19:527AMPlasmaOk
1011:58:37:260AMPlasmaOk
1112:11:23:633PMPlasmaOk
1212:29:58:197PMPlasmaOk
1312:43:18:853PMPlasmaOk
1412:56:05:383PMPlasmaOk
1501:10:32:447PMPlasmaOk
1601:23:46:260PMPlasmaOk
1701:36:52:073PMPlasmaOk
1801:49:51:273PMPlasmaOk
1902:04:49:190PMPlasmaOk
2002:17:39:507PMPlasmaOk
2102:30:42:760PMPlasmaOk
2202:49:25:557PMPlasmaOk
2303:02:37:607PMPlasmaOk
2403:15:47:393PMPlasmaOk
2503:28:51:680PMPlasmaOk
2603:41:41:137PMPlasmaOk
2703:54:36:263PMPlasmaOk
2804:07:33:190PMPlasmaOk
2904:23:07:510PMPlasmaOk
3004:38:32:453PMPlasmaOk
3104:51:52:897PMPlasmaOk
3205:04:54:400PMPlasmaOk