Alcator C-Mod Run 1030424 Information

Back to runs

Miniproposals
Miniproposal:
Date Filed:
Title:
First Author:
Session Leader: Unknown (shots 1-33)

Operators
Session leader(s): Unknown
Physics operator(s):Ron Parker
Engineering operator(s):Bill Byford,Gary Dekow

Engineering Operator Run Comment
Startup PO:Parker; EO:Dekow/Byford

Session Leader Plans

Physics Operators Plans

Session Leader Summaries

Physics Operator Summaries
Entered: Jul 7 2004 04:37:17:537PM
Author: To Be Determined
Run Summary 1030424

This was a clean up run, the third day of running shots since
a long vacuum opening. We started with shot 1030423015 with pre-
programmed gas since the interferometer was in the process of being
brought up. Beginning with shot 6, the interferometer was in
operation and the density was feedback controlled. But the
density was more controlled by recyled gas than the programmed waveform
since only low density (0.5e^20) shots were run. Other key
parameters were Ip = 800 kA and BT = 5.4 t.

The machine ran fairly well for a condiitoning run, the startup was
not as reliable as the previous day.The main problem was heavy runaways,
especially early in the shot. By increasing the initial density the runaway
level could be reduced, however the startup became less reliable.Thus there
were more fizzles than in the previous run day.

We also had some engineering problems with I^2*T faults coming up in several
shots.

In the end, the scorecard read: 18 shots including 1 disruption before rampdown,
3 duds, 5 fizzles and 6 power tests and 1 dud caused by power supply initiation
problem.


RUN PLAN FOR THURSDAY, 24 APRIL 2003

PURPOSE: STARTUP (CONTINUED)

ENGINEERING SETUP

ECDC in D2 overnight prior to run. 60 C bake.

Run Starts at 9:00 AM

Power systems as on 1030422016

Gas setup:

Fill B-Top with 6psi of D2 hybrid enabled (PG4)
Fill B-side lower with 1 psi Ar Hybrid enabled
Fill B-side upper with 10 psi D2 Hybrid Disabled
fill C-side with 30 psi D2 Hybrid enabled

Session Leader Comments

Physics Operator Comments
Apr 24 2003 09:11:12:673AM1030424001Ron ParkerFirst shot was a dud.
Apr 24 2003 09:46:15:460AM1030424002Ron ParkerShot 2 ran well
Apr 24 2003 09:47:09:917AM1030424003Ron ParkerShot 3 ran well
Apr 24 2003 09:56:40:480AM1030424003Ron ParkerFor next shot, density feedback will be on.
Apr 24 2003 10:11:17:733AM1030424004Ron ParkerShot 4 was a dud. Fill gas had dropped about 20%. Raise on next shot.
Apr 24 2003 10:25:02:147AM1030424005Ron ParkerShot 5 was also a dud. Raise fill gas again.
Apr 24 2003 10:54:33:643AM1030424006Ron ParkerShot 6 ran well, density feedback is working.
Lots of hard xrays. We'll try to reduce them by raising the inital
density using pulse gas valve 3.
Apr 24 2003 11:09:34:107AM1030424007Ron ParkerHards are still a problem. We'll continue to raise the initial density.
Apr 24 2003 11:43:54:267AM1030424008Ron ParkerWe are continuing to raise the intial density, but no effect on hards.
Apr 24 2003 11:44:47:787AM1030424009Ron ParkerOn next shot we'll increase the early pulse gas in Seg 1.
Apr 24 2003 12:00:19:497PM1030424010Ron ParkerMaking some progress on hards, but still too strong. We continue to
increase early density.
Apr 24 2003 12:28:48:103PM1030424011Ron ParkerSuccess - shot 11 had low hard x-rays.
Apr 24 2003 12:29:56:307PM1030424012Ron ParkerShot 12 fizzled, too high inital density.
Apr 24 2003 12:34:01:780PM1030424013Ron ParkerThis shot will be a power test.
Apr 24 2003 12:45:26:783PM1030424014Ron ParkerShot 14 fizzled. We'll continue to backoff on initial gas.
Apr 24 2003 12:58:15:490PM1030424015Ron ParkerShot 15 fizzled. We'll reload shot 1030424007
Apr 24 2003 01:10:07:290PM1030424016Ron ParkerShot 16 will be a no-power shot
Apr 24 2003 01:26:29:893PM1030424017Ron ParkerCorection--this was a plasma shot!
As with shot 7, the hards are back. We'll run this once more, then
try the fix suggested by Ian.
Apr 24 2003 01:40:47:417PM1030424018Ron ParkerShot went, hard x-rays are bad and the shot disrupted at 1.4 s.
For next shot, the EF3 preprogrammed voltage will be increased by 50 volts (to 2450)
at t= 12 ms.
Apr 24 2003 01:53:07:717PM1030424019Ron ParkerShot fizzled. It might have been due to previous shot's disruption.

Try again.
Apr 24 2003 02:18:01:440PM1030424020Ron ParkerShot ran OK, but hards are still there.
Apr 24 2003 02:20:16:900PM1030424021Ron ParkerShot 21 was a no-power shot, I^2*T fault came up.
Apr 24 2003 02:38:54:817PM1030424022Ron ParkerShot 22 ran, but hards are a problem.
Apr 24 2003 02:50:28:477PM1030424023Ron ParkerStarting to increase density to reduce hard x-ray problem.

Next shot, density will be increased to 1.0e20.
Apr 24 2003 03:23:12:713PM1030424024Ron ParkerShot 24 ran with nl4 = 1.e20.
Hards reduced after high density is reached.
Apr 24 2003 03:24:11:513PM1030424025Ron ParkerShot 25 disrupted at about 50 msec.
Apr 24 2003 03:36:24:470PM1030424026Ron ParkerThis shot was a fizzle, probably because of the disruption in shot 25.
Apr 24 2003 03:50:53:283PM1030424027Ron ParkerShot 27 was a dud. There was an EF power supply failure to initialize.
Apr 24 2003 03:56:55:730PM1030424028Ron ParkerShot 28 was a no-power shot.
Apr 24 2003 04:32:48:753PM1030424029Ron ParkerShot 29 will be a no-power shot
Apr 24 2003 04:34:16:663PM1030424030Ron ParkerShot 30 went off, although there was a hesitiation during the current rise.
Apr 24 2003 04:46:06:667PM1030424031Ron ParkerShot 31 went off OK, but the hards remain a problem.
Apr 24 2003 04:53:17:880PM1030424032Ron ParkerThis shot will be a baseline shot for diagnostic calibration (aka a no-power shot).
Apr 24 2003 05:27:31:527PM1030424033Ron ParkerShot 33 went off OK. Still have the hard x-ray problem.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:05:54:197AMPlasmaOk
209:19:08:250AMPlasmaOk
309:34:01:210AMPlasmaOk
409:58:07:620AMPlasmaOk
510:11:10:983AMPlasmaOk
610:24:03:850AMPlasmaOk
710:55:39:037AMPlasmaOk
811:20:54:687AMPlasmaOk
911:34:42:347AMPlasmaOk
1011:47:44:180AMPlasmaOk
1112:00:55:200PMPlasmaOk
1212:13:37:343PMPlasmaOk
1312:30:30:510PMPlasmaBadCamac Init Error on BUSHV DDECODER
1412:40:43:573PMPlasmaOk
1512:53:20:687PMPlasmaOk
1601:07:50:350PMPlasmaBadI2T Fault
1701:18:09:320PMPlasmaOk
1801:31:21:980PMPlasmaOk
1901:44:48:780PMPlasmaOk
2001:59:54:727PMPlasmaOk
2102:15:11:657PMPlasmaBadI2T fault
2202:25:38:373PMPlasmaOk
2302:39:00:880PMPlasmaOk
2402:52:38:917PMPlasmaOk
2503:07:55:940PMPlasmaBadOH2U/L Comm Fault OH1 Self Powered Circuit fired
2603:26:09:170PMPlasmaOk
2703:40:25:097PMPlasmaBadCamac Problem Power Supply
2803:53:23:537PMPlasmaBadCamac Problem no Power Shot
2904:11:35:347PMTestOkCamac test shot
3004:21:37:690PMPlasmaOk
3104:37:07:510PMPlasmaOk
3204:51:54:677PMPlasmaBadI2T Problem Baseline Shot
3305:02:58:270PMPlasmaOk