| Engineering Operator Run Comment |
| MP #322 MSE Calibration/Yuh/SScott/Wolfe/Marmar/Byford |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:32:413PM |
| Author: To Be Determined |
| Run Summary: MP#314 MSE Calibration 1030521 Run plan accomplished the following: C-Mod# Plan# Index TF (T) EF4(kA) EF3(kA) special Value Notes 004 1 00 5.4 0 0 007 2 01 5.4 -1 0 008 3 02 5.4 3 0 009 5 03 5.4 5 0 010 6 04 5.4 0 2 011 7 05 5.4 0 4 - - 25ms beam 012 8 06 5.4 0 6 013 9.5 07 5.4 5 3 014 11 08 5.4 5 6 - - 25ms beam 015 12 09 5.4 3 6 016 12A 10 5.4 -3 0 017 12B 11 5.4 -5 0 018 12C 12 5.4 -1 0 019 13 13 5.4 0 0 020 14 14 2.7 0 0 022 17 15 2.7 2.5 0 023 18 16 2.7 5 0 024 18A 17 2.7 -5 0 025 21 18 2.7 0 3 026 22 19 2.7 0 6 027 17A 20 2.7 -2.5 0 028 14R 21 2.7 0 0 029 28 22 5.4 0 0 030 29 23 5.4 0 0 EF-1U -5kA 031 30 24 5.4 0 0 EF-2U -5kA 032 9.5R 25 5.4 5 3 033 5R 26 5.4 5 0 035 23 27 4.5 0 0 |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:17:957PM |
| Author: To Be Determined |
| Physop run summary 1030521 MP#322 MSE Calibration ---------------------------------------------------------------------------- 1030521xxx wolfe PHYSICS_OPERATOR May 21 2003 8:33:26:600AM . . . . . . . . . . . . . . . . . . . . Engineering setup and Run Plan for Wednesday, May 21 MP#322 MSE Calibration SL: Yuh, SScott PO: wolfe/marmar NO Overnight ECDC. Engineering systems as on 1021004003 Except: Fizzle detector on at 1.05 sec, off at 1.1 sec all supplies invert time set to 1.0sec For OH1,OH2U,OH2L,EF1U,EF2L: open times set to 7sec, crowbar to 7.1 and charging banks disabled in Paragon (no commutation) For all shots not using EF3, the EF3 control power should be OFF A-coil patch panel should be set up for +Gtop only (all others zero) For the first shot, enable only TF (hybrid control) Gas setup: Fill B-top with 6psi D2 Hybrid Enabled (PG4) All other valves NOT FILLED and NOT ENABLED Torus Gate Valves closed during pulse Enable the DNB Gate valve (assuming no vacuum problems) All trees enabled except RF Plan: ----- We'll be firing TF + one or more PF (or A-coils) with gas and DNB to calibrate the MSE diagnostic. PCS: Start from 1021004009 (which has IC_EF3 control on wire8); only segment 1 is used. Start with a TF-only shot and follow the SL plan for various PF and A-coil currents. Note that when/if we get to the OH2U and OH2L shots the predictor and controller for wire 10 will need to be changed, since the "IC_OH2U" feedback actually controls the average current in the oh2's and this plan requires them to run individually; should probably set these up ahead of time. All supplies will be run with flattop through 0.8sec, with the beam firing at .70 to .75sec, to minimize transient and eddy current effects. Btop gas puff should be moved from -.5 to +.4sec and increased from 332msec to 500msec (target pressure is 1.5mTorr @0.7sec); pressure should be checked and retuned if necessary after the first shot. Results: From the Physop point of view, this was a low stress run. The run got off to a slow start, because of DNB gate-valve interlock issues, but once we got started, things went quite smoothly. Many combinations of fields were run, and we successfully had 34 duds. Shot 5 was a no-power test; didn't get bus or alternator data on shot 4. |
| Session Leader Comments |
| Physics Operator Comments | |||
| May 21 2003 08:08:14:340AM | Steve Wolfe | Setting up for MSE Calibration Run. LoadFrom 10201004009 On ALL_V screen: extend TF_CUR pulse to 0.8sec Draw pg4 pulse from -.1 to .4 Draw ACOIL_CUR to 3700A from .1 to .8 (200msec ramp up/down)Change wire 9 from IC_OH1 to IC_OH2L alg="ROGOWSKI" /call; extend P gain=4 to 1.5sec; change controller to gain .01 on OH2L_Volt MOdify wire 10 IC_OH2U alg="ROGOWSKI"/call; extend Pgain=4 to 1.5sec; change controller to gain .01 on OH2U_Volt On ALL_P's screen: IC_EF3 to 2000 until 0.8sec (case 6) IC_OH2L to 15kA (0.1 to 0.8sec) (start -1.1) (case32) NOTE: Need to change switch close time to 6sec for reverse polarity, then back to -.7 for case 37. IC_OH2U to -15kA (-.1 to .8, start at -1.1, end at 1.2) (case31) NOTE: Need to change close time to +6 for case 36 reverse polarity case. IC_EF1U to -5kA start -1.2 (case29) IC_EF2U to -5kA start at -.5 (case 30) IC_EF4U to -1000 (case2) Load/clean at 21-May-2003 08:07:50.00 | |
| May 21 2003 08:17:04:133AM | Steve Wolfe | Change timing on IC_EF3 waveform Load at 21-May-2003 08:14:19.00 Re-do the coldstart, it may have been running while I was doing the previous load rtnode -- data loaded, A matrix responds rtnode -- data loaded, M matrix responds rtnode -- data loaded, PID matrix responds RT_NODE Done Wed May 21 08:16:23 2003, Done \CMOD::TOP.HYBRID.HARDWARE.BITBUS:RT_NODE:EXEC_ACTION in CMOD shot -1, status=1 *************** END COLDSTART ****************** | |
| May 21 2003 08:33:26:600AM | Steve Wolfe | Engineering setup and Run Plan for Wednesday, May 21 MP#322 MSE Calibration SL: Yuh, SScott PO: wolfe/marmar NO Overnight ECDC. Engineering systems as on 1021004003 Except: Fizzle detector on at 1.05 sec, off at 1.1 sec all supplies invert time set to 1.0sec For OH1,OH2U,OH2L,EF1U,EF2L: open times set to 7sec, crowbar to 7.1 and charging banks disabled in Paragon (no commutation) For all shots not using EF3, the EF3 control power should be OFF A-coil patch panel should be set up for +Gtop only (all others zero) For the first shot, enable only TF (hybrid control) Gas setup: Fill B-top with 6psi D2 Hybrid Enabled (PG4) All other valves NOT FILLED and NOT ENABLED Torus Gate Valves closed during pulse Enable the DNB Gate valve (assuming no vacuum problems) All trees enabled except RF Plan: ----- We'll be firing TF + one or more PF (or A-coils) with gas and DNB to calibrate the MSE diagnostic. PCS: Start from 1021004009 (which has IC_EF3 control on wire8); only segment 1 is used. Start with a TF-only shot and follow the SL plan for various PF and A-coil currents. Note that when/if we get to the OH2U and OH2L shots the predictor and controller for wire 10 will need to be changed, since the "IC_OH2U" feedback actually controls the average current in the oh2's and this plan requires them to run individually; should probably set these up ahead of time. All supplies will be run with flattop through 0.8sec, with the beam firing at .70 to .75sec, to minimize transient and eddy current effects. Btop gas puff should be moved from -.5 to +.4sec and increased from 332msec to 500msec (target pressure is 1.5mTorr @0.7sec); pressure should be checked and retuned if necessary after the first shot. Shot sequence, with priorities, is as follows: # Priority TF (T) EF4(kA) EF3(kA) special Value 1 A 5.4 0 0 2 A 5.4 -1 0 3 A 5.4 3 0 4 A 5.4 4 0 5 A 5.4 5 0 6 A 5.4 0 2 7 A 5.4 0 4 8 A 5.4 0 6 9 A 5.4 5 2 10 A 5.4 5 4 11 A 5.4 5 6 12 A 5.4 3 6 13 A 5.4 0 0 14 A 2.7 0 0 15 B 2.7 -0.5 0 16 B 2.7 1.5 0 17 A 2.7 2.5 0 18 A 2.7 5 0 19 B 2.7 0 1 20 A 2.7 0 2 21 A 2.7 0 3 22 A 2.7 0 6 23 A 4.5 0 0 24 C 4.5 3 0 25 B 4.5 5 0 26 C 4.5 0 3 27 B 4.5 0 6 28 B 5.4 0 0 29 B 5.4 0 0 EF-1U -5kA 30 B 5.4 0 0 EF-2U -5kA 31 B 5.4 0 0 OH-2U -15kA 32 B 5.4 0 0 OH-2L 15kA * Switch close to +6.7sec 33 B 5.4 0 0 Gtop 3kA 34 C 5.4 0 0 EF-1U 5kA * Switch close to +6.7sec 35XX C 5.4 0 0 EF-2U 5kA XXX Can't do + current in EF2 36 C 5.4 0 0 OH-2U 15kA * Switch close to +6.7sec 37 C 5.4 0 0 OH-2L -15kA * Switch close to -0.7sec | |
| May 21 2003 09:09:42:220AM | 1030521001 | Steve Wolfe | shot#1: TF only at -150kA Got tf and gas; ratiomatic claims 2mT no beam next shot: repeat |
| May 21 2003 09:38:17:633AM | 1030521002 | Steve Wolfe | shot#2: TF only at -150kA (repeat) still no beam. try again. |
| May 21 2003 09:56:43:590AM | 1030521003 | Steve Wolfe | shot#3: TF only at -150kA (repeat) still no beam. It looks like the gate valve permissive is not getting through. Joe and Yuri are looking into the problem |
| May 21 2003 10:15:18:077AM | 1030521004 | Steve Wolfe | shot#4: TF only at -150kA (repeat) The turbo was off, which is interlocked to the torus valve. Once that was started, the permissive came on on the DNB paragon screen Got the beam, got data. next shot: EF4 at -1kA |
| May 21 2003 10:37:07:770AM | 1030521005 | Steve Wolfe | shot#5: No power shot to see why we didn't get any bus or alternator data on shot#4. Looks like bus currents are there this time. Next shot: tf=-150, EF4=-1kA with beam (case 2) |
| May 21 2003 10:58:30:370AM | 1030521006 | Earl Marmar | Taking over from Wolfe. condition # 2: -1 kA EF4, 0 kA EF3 fields look ok beam fired, but at the wrong time |
| May 21 2003 11:02:47:363AM | 1030521007 | Earl Marmar | condition #2 again got the fields beam at correct time |
| May 21 2003 11:24:11:710AM | 1030521008 | Earl Marmar | condition #3 TF 5.4 T, EF4 +3 kA got the fields |
| May 21 2003 11:29:06:750AM | 1030521009 | Earl Marmar | skipping condition 4, going to condition 5 B = 5.4 T, EF4 = +5 kA got the fields |
| May 21 2003 11:48:32:743AM | 1030521010 | Earl Marmar | condition 6 B = 5.4 T, EF4 = 0, EF3 = 2 kA got about 2500 A in EF3's |
| May 21 2003 11:54:01:343AM | 1030521011 | Earl Marmar | condition 7 B = 5.4 T, EF3 = 4 kA (ask for 3.5 kA) fields ok |
| May 21 2003 12:06:17:617PM | 1030521012 | Earl Marmar | condition 8 B = 5.4 T, EF3 = 6 kA fields ok |
| May 21 2003 12:19:20:280PM | 1030521013 | Earl Marmar | condition 9.5 B = 5.4 T, EF4 = +5 kA, EF3 = 3 kA fields ok |
| May 21 2003 12:34:04:530PM | 1030521014 | Earl Marmar | condition 11 B = 5.4 T, EF4 = +5 kA, EF3 = 6 kA fields ok |
| May 21 2003 12:48:01:793PM | 1030521015 | Earl Marmar | condition 12 B = 5.4 T, EF4 = +3 kA, EF3 = 6 kA fields look ok |
| May 21 2003 01:09:27:080PM | 1030521016 | Earl Marmar | condition 12A B = 5.4 T, EF4 = -3 kA, EF3 = 0 fields ok |
| May 21 2003 01:10:17:393PM | 1030521017 | Earl Marmar | condition 12B B = 5.4 T, EF4 = -5 kA, EF3 = 0 fields ok |
| May 21 2003 01:33:17:520PM | 1030521018 | Earl Marmar | condition 12C B = 5.4 T, EF4 = -1 kA, EF3 = 0 fields ok |
| May 21 2003 01:44:56:730PM | 1030521019 | Earl Marmar | condition 13 B = 5.4 T, EF4 = 0, EF3 = 0 fields ok |
| May 21 2003 02:07:08:923PM | 1030521020 | Earl Marmar | condition 14 B = 2.7 T, EF4 = 0, EF3 = 0 field ok |
| May 21 2003 02:23:45:703PM | 1030521021 | Earl Marmar | condition 17 B = 2.7 T, EF4 = 2.5 kA, EF3 = 0 fields ok short beam pulse |
| May 21 2003 02:34:30:213PM | 1030521022 | Earl Marmar | repeat condition 17 B = 2.7 T, EF4 = 2.5 kA, EF3 = 0 fields ok |
| May 21 2003 02:45:53:943PM | 1030521023 | Earl Marmar | condition 18 B = 2.7 T, EF4 = 5 kA, EF3 = 0 fields ok |
| May 21 2003 03:00:57:617PM | 1030521024 | Earl Marmar | condition 18A B = 2.7 T, EF4 = -5 kA, EF3 = 0 fields ok |
| May 21 2003 03:11:57:783PM | 1030521025 | Earl Marmar | condition 21 B = 2.7 T, EF4 = 0, EF3 = 3 kA fields ok |
| May 21 2003 03:23:22:153PM | 1030521026 | Earl Marmar | condition 22 B = 2.7 T, EF4 = 0, EF3 = 6 kA fields ok |
| May 21 2003 03:37:09:187PM | 1030521027 | Earl Marmar | condition 17A B = 2.7 T, EF4 = -2.5 kA, EF3 = 0 fields ok |
| May 21 2003 03:48:38:260PM | 1030521028 | Earl Marmar | condition 14 (repeat) B = 2.7 T, EF4 = 0, EF3 = 0 field ok |
| May 21 2003 04:01:21:487PM | 1030521029 | Earl Marmar | condition 28 B = 5.4 T, EF4 = 0, EF3 = 0 field ok |
| May 21 2003 04:16:52:720PM | 1030521030 | Earl Marmar | condition 29 B = 5.4 T, EF1U = -5kA fields ok |
| May 21 2003 04:42:55:640PM | 1030521031 | Earl Marmar | condition 30 B = 5.4 T, EF2U = -5kA fields ok significant induced currents in EFC and EF4 |
| May 21 2003 04:43:48:000PM | 1030521032 | Earl Marmar | condition 9A (repeat) B = 5.4 T, EF4 = 5 kA, EF3 = 3 kA fields ok |
| May 21 2003 04:56:41:033PM | 1030521033 | Earl Marmar | condition 5 (repeat) B = 5.4 T, EF4 = 5 kA, EF3 = 0 fields ok |
| May 21 2003 05:29:04:613PM | 1030521034 | Earl Marmar | condition 23 B = 4.5 T, EF4 = 0, EF3 = 0 no TF |
| May 21 2003 05:29:45:893PM | 1030521035 | Earl Marmar | condition 23 (try again) B = 4.5 T, EF4 = 0, EF3 = 0 worked this time. field ok. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:01:38:250AM | Test | Ok | |
| 2 | 09:25:05:303AM | Test | Ok | |
| 3 | 09:38:45:850AM | Test | Ok | |
| 4 | 10:11:42:237AM | Test | Ok | |
| 5 | 10:34:06:730AM | Test | Ok | |
| 6 | 10:42:59:683AM | Test | Ok | |
| 7 | 10:57:49:840AM | Test | Ok | |
| 8 | 11:10:16:083AM | Test | Ok | |
| 9 | 11:22:41:760AM | Test | Ok | |
| 10 | 11:37:57:187AM | Test | Ok | |
| 11 | 11:50:40:490AM | Test | Ok | |
| 12 | 12:03:15:997PM | Test | Ok | |
| 13 | 12:16:05:550PM | Test | Ok | |
| 14 | 12:28:46:980PM | Test | Ok | |
| 15 | 12:41:21:430PM | Test | Ok | |
| 16 | 12:53:55:703PM | Test | Ok | |
| 17 | 01:06:37:023PM | Test | Ok | |
| 18 | 01:28:50:763PM | Test | Ok | |
| 19 | 01:42:02:987PM | Test | Ok | |
| 20 | 02:03:52:007PM | Test | Ok | |
| 21 | 02:16:26:967PM | Test | Ok | |
| 22 | 02:29:53:240PM | Test | Ok | |
| 23 | 02:42:44:933PM | Test | Ok | |
| 24 | 02:55:31:767PM | Test | Ok | |
| 25 | 03:08:04:103PM | Test | Ok | |
| 26 | 03:20:39:673PM | Test | Ok | |
| 27 | 03:33:25:307PM | Test | Ok | |
| 28 | 03:46:28:123PM | Test | Ok | |
| 29 | 03:58:59:567PM | Test | Ok | |
| 30 | 04:11:42:277PM | Test | Ok | |
| 31 | 04:24:27:520PM | Test | Ok | |
| 32 | 04:37:07:120PM | Test | Ok | |
| 33 | 04:49:50:237PM | Test | Ok | |
| 34 | 05:02:24:320PM | Test | Bad | TF did not fire |
| 35 | 05:10:19:260PM | Test | Ok | |