Alcator C-Mod Run 1030610 Information

Back to runs

Miniproposals
Miniproposal:303
Date Filed: 6/21/2002
Title:High Performance ITBs
First Author:John Rice
Session Leader:John Rice (shots 1-28)

Operators
Session leader(s):John Rice
Physics operator(s):Robert Granetz
Engineering operator(s): Unknown

Engineering Operator Run Comment
Purpose: MP 303 - High Performance ITB's/Rice/Granetz

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:33:117PM
Author: John Rice
Session Leader Run Summary for 1030610 MP303 High Performance ITBs

Precious few ITBs were obtained, shots 14, 16, 18 and 24, and none
would qualify as high performance. The discharges were plagued by
repeated H-L transitions which prevented the ITBs from developing.
The RF performed very well with many shots over 3.5 MW. The H/D
ratio was not too bad, but Mo levels were somewhat high. The best
ITB was on shot 14 at 4.5T, but was it high performance? Not with
an H-factor of .82 it wasn't. The other decent ITB was on shot 24
at 6.4T, which exhibited a very narrow density and x-ray peaking,
as was seen last year. Was shot 24 high performance? Not with an
H-factor of .85 it wasn't. We were barely able to produce any
ITBs, let alone decent ones, let alone high performance ones.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:18:177PM
Author: Robert Granetz
Physics operator summary for run 1030610 (Tuesday):

MP 303 - High Performance ITB's

Session leader: J. Rice
Physics operator: R. Granetz
Engineers in charge:

Summary: We got some short H-mode ITB's with inboard-side resonance on
shots 14, 16, 17, and 18 (4.5 T, 0.8 MA, Prf=3.4 MW). We then
switched to 6.4 T to do outboard-side resonance on shots 20 and
24. We got full-length plasmas on both shots, but the TF
crowbarred both times, necessitating long delays and multiple
TF-only test shots. Nevertheless, I think shot 24 had a long
ITB (t=1.3-1.5 s). The x-ray profile was very narrow, and the
Thomson profiles were peaked, but over a very small radius
(consistent with John Rice's previous observations.)

Other than the crowbars, the machine ran well. There were no
fizzles or duds, and all shots had full rampdowns. There were no
disruptions. After shot 20, the network server for the paragon
stations crashed, necessitating a reboot of all the paragon
stations.

Scorecard: 21 plasmas
0 fizzles
0 duds
6 test or no-power shot cycle
0 aborted and/or screwed up by computer problems
----------
27 total

-------------------------------------------------------------------------------
Engineering setup for Tuesday, 10 June 2003

Purpose: MP 303 - High Performance ITB's

Session leader: J. Rice
Physics operator: R. Granetz

ECDC overnight in D2 at 2e-4 Torr, stopping by 07:00.
Bake at 60 C overnight as well, if possible.

Run begins at 09:00 and ends at 17:00.

If RF has fired into the vacuum chamber prior to the start of the run, then
we will need to do 10 minutes of ECDC before the first shot.

Power systems the same as on 1030605028 (0.8 MA, 5.4 T, lower single null)

A-coils should be hooked up as on 1030507027 (+Dtop -Dbot -Jtop +Jbot), but
the power supply should NOT be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
fill B-side upper with 10 psi D2 Hybrid DISABLED (PG2) (for ECDC)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves, assuming no vacuum problems:
ECE, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 08:00. We want 5 MW today.

-------------------------------------------------------------------------------
Run Plan: Start by getting good ITB's at 4.5 T, 0.8 MA, and 5 MW of ICRF
(off-axis on inboard side) At some point we will switch to 6.1 T,
1.2 MA, and 5 MW (off-axis on outboard side) to get high
performance ITB's. (A-coils will be needed for the 1.2 MA
discharges.) Obtain high quality Te, Ti, ne, and Vtor profiles.
Vary DNB timing relative to the ITB evolution.

-------------------------------------------------------------------------------

ECDC was done overnight, as well as a 60 C bake.

Hybrid coldstart done by the engineering group; no errors found

Loaded PCS segment 2 from shot 1030605028 (0.8 MA, 5.4 T, single
null lower), segment 1 from shot 1030606035 (last shot from last
Friday). Changed BT to be 4.5 T (125 kA) in segment 2.

-------------------------------------------------------------------------------

Shot 01 -- Plasma. Good shot. Prf=0.5+1.5+0=2 MW (D+E+J). Btor=4.58 T.
Ip=0.8 MA. Target nl_04=0.9e20 m-2. Great startup, even though
Br0=-2.6 mT ! No early hard x-rays. John thinks there was an
ITB (inboard resonance), but the core Thomson was not on for the
first shot. It will be on for the 2nd shot. GPC2 needs to be
recalibrated.

Next shot: increase argon puff by 10 ms. More RF power.

Shot 02 -- Plasma. Good shot. Prf=0.5+1.5+0=2 MW. Horrible startup, huge
Br0, some hard x-rays, almost lost it. H/D=4-8%.

Next shot: increase Br0 by 0.25 mT (to 0.000 T)

Shot 03 -- Plasma. Good shot. Good startup. Prf=0.6+1.4+1.6=3.1 MW.
No ITB's except at H-L back transitions. Now have my peaking
scope working with both ne0/nebar and xray_width.

Next shot: no PCS changes. More RF power.

Shot 04 -- Plasma. Good shot. Good startup. Prf=0.7+1.4+1.1=3.2 MW.
Still no ITB's except at H-L back transitions.

Next shot: raise density by 10% (0.8e20 --> 0.9e20 m-2)

Shot 05 -- No-power cycle. TCI failed before the shot, so I opted to turn
off the supplies rather than a wide open gas valve.

Shot 06 -- Plasma. Good Shot. Startup was not as good as shot 04.
Target nl_04=1.0e20 m-2. Some hard x-rays. Still no ITB's
except for H-L back transitions.

Next shot: no PCS changes

Shot 07 -- Plasma. Good shot. Prf=0.8+1.7+~0 = 2.5 MW. Still only have
the H-L back transition ITB's. Startup is not great, with some
hard x-rays.

Next shot: reduce Btor by 2% (from 4.58 to 4.50 T)

Shot 08 -- Plasma. Good shot. Btor=4.50 T. No TCI data (camac problem), so
no ne peaking, but x-ray width indicates that ITB's formed before
the H-L back transitions, finally! Prf=0.9+1.5+~0=2.4 MW.
One of the TF joints is showing a high temperature.

Next shot: TF-only test shot (5.4 T) to check joint temperature.

Shot 09 -- Test. 5.4 tesla TF-only shot to check joint resistance. Seems
to be okay on the TF scanner.

Next shot: back to plasma operation

Shot 10 -- Plasma. Good shot. Btor=4.51 T. No H-mode ITB's.
Prf=0.9+1.4+1.1=3.4 MW. H/D=4-6%.

Next shot: no PCS changes.

Shot 11 -- Plasma. Good shot. Prf=3.3 MW. No H-mode ITB's. H/D=6%.

Next shot: raise density another 10%.

Shot 12 -- Plasma. Good shot. nl_04=1.1e20 m-2. Prf=0+1.5+0=1.5 MW, so
only got one H-mode. Great startup; no hard x-rays.

Next shot: no PCS changes.

Shot 13 -- Plasma. Good shot. Prf=1.0+1.5+0=2.5 MW. H/D=4-6%. Good startup.
No H-mode ITB's.

Next shot: no PCS changes.

Shot 14 -- Plasma. Good shot. Got a good ITB on the 2nd H-mode! Good
startup. Prf=0.9+1.4+1.1=3.4 MW. H/D=4-5%.

Next shot: reduce Btor by another 1% (I_TF=121500 A). Increase
argon puff by another 10 ms.

Shot 15 -- Plasma. Good shot. No H-mode ITB's Prf=0.9+1.4+1.1=3.4 MW.
H/D=4-6%. Good startup.

Next shot: add the 1% back to Btor.

Shot 16 -- Plasma. Good shot. Got another ITB on the final H-mode!
Prf=1.0+1.4+1.0=3.4 MW. H/D=4-6%. Good startup.

Next shot: no PCS changes.

Shot 17 -- Plasma. Good shot. Got another ITB on the final H-mode.
Prf=1.0+1.4+1.0=3.4 MW. H/D=4-6%. Good startup.

Next shot: no PCS changes.

Shot 18 -- Plasma. Good shot. Another H-mode ITB, but not as clear as the
previous ones today. Prf=1.0+1.4+1.0=3.4 MW. H/D=6%.

Next shot: no PCS changes. The DNB is firing at t=1.35 s.

Shot 19 -- Plasma. Good shot. Bad startup, lots of hard x-rays. TCI failed
on channel 4. Density feedback failed. J-port RF dropped out
early. No ITBs.

Next shot: go to other half of the MP. Raise Bt to 6.4 T, Ip
to 0.9 MA. Decrease density to nl_04=0.8e20 m-2.

Shot 20 -- Plasma. Full-length shot, but TF crowbarred. Bt=6.4 T, Ip=0.9 MA.
TCI failed again -- no feedback, so density was too high.
Prf=3.3 --> 2 --> 1 MW. Multiple H-modes, but no ITB's. The
paragon server node crashed, so all of the paragon PC's will have
to be rebooted before the next shot. The DNB suddenly developed
a problem with the beam current signal.

Next shot: TF-only test.

Shot 21 -- Test. TF-only, 50 kA. OK

Next shot: 150 kA TF-only test.

Shot 22 -- No power. Should have been a 150 kA TF-only test.

Next shot: 150 kA TF-only test.

Shot 23 -- Test. TF-only, 150 kA. OK

Next shot: back to 6.4 T plasma operation

Shot 24 -- Plasma. Good shot, but the TF crowbarred again. BT=6.4 T,
Ip=0.9 MA, Prf=~0 + 1.4+1.1=2.5 MW. H/D=7%. I think this
had a long ITB (from 1.3 to 1.5 s) during the H-mode, judging
from the x-ray peaking. Dmitri reports that the Thomson shows
a very small diameter peaked region.

Next shot: 50 kA TF-only test.

Shot 25 -- Test. 50 kA TF-only test. OK

Next shot: plasma, with Bt=5.4 T, Ip=0.8 MA

Shot 26 -- Plasma. Good shot. Btor=5.4 T, Ip=0.8 MA, nl (target) = 0.9e20 m-2
Prf=0.5+1.4+1.1=3.0 MW. H/D=6-8%. H-modes, no ITBs.

Next shot: get a start on tomorrow's run. Load segment 2 from
1030529016, except reduce nl_04 to 1.0e20 m-2, and turn on the
A-coils in the normal suppression configuration. Bt=5.4 T,
Ip=1.0 MA.

Shot 27 -- Plasma. Good shot. Bt=5.4, Ip=1.0 MA, nl(target)=1.1e20 m-2, and
Prf=3.0-3.6 MW. Lots of short (ELM-free?) H-modes. Startup was
bad though.

End of run.

Session Leader Comments
Jun 10 2003 09:08:20:540AM1030610001John Rice4.6 T, 2 MW ICRF w/ some trips
some indication of an ITB at 1.1 s
Jun 10 2003 09:27:35:563AM1030610002John Rice4.6 T, 2 MW ICRF
ITB? who knows?
Jun 10 2003 09:52:38:313AM1030610003John Rice4.6 T, 3 MW ICRF
ITB? H-L transition at .95 s spoiled it
Jun 10 2003 10:05:57:697AM1030610004John Rice4.6 T, 3 MW ICRF
no ITB, too many H-L transitions
Jun 10 2003 10:51:39:317AM1030610005John Riceno power shot
Jun 10 2003 10:51:25:753AM1030610006John Riceugly
Jun 10 2003 11:06:22:893AM1030610007John Rice4.58 T, 1.5 MW RF
ITB at 1.3 s
Jun 10 2003 11:25:18:897AM1030610008John Rice4.5 T, 2 MW RF
ITB? no
Jun 10 2003 11:36:47:967AM1030610009John Rice0 T, 0 MW RF
no ITB
Jun 10 2003 11:49:15:507AM1030610010John Rice4.5 T, 3.5 MW RF
ITB at 1.4 s
Jun 10 2003 12:00:11:200PM1030610011John Rice4.5 T, 3.5 MW RF
ITB late
Jun 10 2003 12:16:55:310PM1030610012John Rice4.5 T, 1.5 MW RF
late H-mode, no ITB
Jun 10 2003 12:28:14:863PM1030610013John Rice4.5 T, 2.5 MW RF
couple of ITBs
Jun 10 2003 12:46:44:507PM1030610014John Rice4.5 T, 3.5 MW RF
good ITB
Jun 10 2003 12:55:38:057PM1030610015John Rice4.5 T, 3.5 MW RF
late ITBs, many trips
Jun 10 2003 01:11:38:337PM1030610016John Rice4.5 T, 3.5 MW RF
late ITB, many H-L transitions
Jun 10 2003 01:27:15:290PM1030610017John Rice4.5 T, 2.5 MW RF
late ITB, many H-L transitions
Jun 10 2003 01:34:59:960PM1030610018John Rice4.5 T, 3.5 MW RF
late ITB, many H-L transitions
Jun 10 2003 02:11:52:280PM1030610019John Rice4.5 T, 3.5 MW RF
?
Jun 10 2003 02:12:07:700PM1030610020John Rice6.5 T, 3.5 MW RF
many trips
Jun 10 2003 03:04:05:677PM1030610021John Ricetest
Jun 10 2003 03:48:26:700PM1030610022John Ricetest
Jun 10 2003 03:48:32:810PM1030610023John Ricetest
Jun 10 2003 03:53:56:663PM1030610024John Rice6.4 T, 2.5 MW
trips, no ITB
Jun 10 2003 04:07:06:563PM1030610024John Rice6.4 T, 2.5 MW
trips, late, narrow ITB
Jun 10 2003 04:34:07:817PM1030610025John Rice0 T, 0 MW
test
Jun 10 2003 04:48:57:567PM1030610026John Rice5.4 T, 3 MW
no ITB
Jun 10 2003 04:59:17:977PM1030610027John Rice5.4 T, 3 MW
no ITB
Jun 11 2003 10:25:51:883AM1030610028Earl MarmarThis was really the first shot of June 11, 2003, but because of a data system quirk, is stored as 1030610028.

Decent plasma; got the decreased upper triangularity. Multiple H-modes, looking pretty ELM-free.

H/(H+D) = 0.6

~3.5 MW RF

Physics Operator Comments
Jun 10 2003 07:57:34:983AMRobert GranetzEngineering setup for Tuesday, 10 June 2003

Purpose: MP 303 - High Performance ITB's

Session leader: J. Rice
Physics operator: R. Granetz

ECDC overnight in D2 at 2e-4 Torr, stopping by 07:00.
Bake at 60 C overnight as well, if possible.

Run begins at 09:00 and ends at 17:00.

If RF has fired into the vacuum chamber prior to the start of the run, then
we will need to do 10 minutes of ECDC before the first shot.

Power systems the same as on 1030605028 (0.8 MA, 5.4 T, lower single null)

A-coils should be hooked up as on 1030507027 (+Dtop -Dbot -Jtop +Jbot), but
the power supply should NOT be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
fill B-side upper with 10 psi D2 Hybrid DISABLED (PG2) (for ECDC)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves, assuming no vacuum problems:
ECE, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 08:00. We want 5 MW today.

-------------------------------------------------------------------------------
Run Plan: Start by getting good ITB's at 4.5 T, 0.8 MA, and 5 MW of ICRF
(off-axis on inboard side) At some point we will switch to 6.1 T,
1.2 MA, and 5 MW (off-axis on outboard side) to get high
performance ITB's. (A-coils will be needed for the 1.2 MA
discharges.) Obtain high quality Te, Ti, ne, and Vtor profiles.
Vary DNB timing relative to the ITB evolution.
Jun 10 2003 07:57:53:483AMRobert Granetz ECDC was done overnight, as well as a 60 C bake.

Hybrid coldstart done by the engineering group; no errors found

Loaded PCS segment 2 from shot 1030605028 (0.8 MA, 5.4 T, single
null lower), segment 1 from shot 1030606035 (last shot from last
Friday). Changed BT to be 4.5 T (125 kA) in segment 2.
Jun 10 2003 09:13:14:847AM1030610001Robert GranetzShot 01 -- Plasma. Good shot. Prf=0.5+1.5+0=2 MW (D+E+J). Btor=4.58 T.
Ip=0.8 MA. Target nl_04=0.9e20 m-2. Great startup, even though
Br0=-2.6 mT ! No early hard x-rays. John thinks there was an
ITB (inboard resonance), but the core Thomson was not on for the
first shot. It will be on for the 2nd shot. GPC2 needs to be
recalibrated.

Next shot: increase argon puff by 10 ms. More RF power.
Jun 10 2003 09:25:32:137AM1030610002Robert GranetzShot 02 -- Plasma. Good shot. Prf=0.5+1.5+0=2 MW. Horrible startup, huge
Br0, some hard x-rays, almost lost it. H/D=4-8%.

Next shot: increase Br0 by 0.25 mT (to 0.000 T)
Jun 10 2003 09:52:18:407AM1030610003Robert GranetzShot 03 -- Plasma. Good shot. Good startup. Prf=0.6+1.4+1.6=3.1 MW.
No ITB's except at H-L back transitions. Now have my peaking
scope working with both ne0/nebar and xray_width.

Next shot: no PCS changes. More RF power.
Jun 10 2003 10:15:38:000AM1030610004Robert GranetzShot 04 -- Plasma. Good shot. Good startup. Prf=0.7+1.4+1.1=3.2 MW.
Still no ITB's except at H-L back transitions.

Next shot: raise density by 10% (0.8e20 --> 0.9e20 m-2)
Jun 10 2003 10:29:30:947AM1030610005Robert GranetzShot 05 -- No-power cycle. TCI failed before the shot, so I opted to turn
off the supplies rather than a wide open gas valve.
Jun 10 2003 10:59:04:470AM1030610006Robert GranetzShot 06 -- Plasma. Good Shot. Startup was not as good as shot 04.
Target nl_04=1.0e20 m-2. Some hard x-rays. Still no ITB's
except for H-L back transitions.

Next shot: no PCS changes
Jun 10 2003 11:07:35:490AM1030610007Robert GranetzShot 07 -- Plasma. Good shot. Prf=0.8+1.7+~0 = 2.5 MW. Still only have
the H-L back transition ITB's. Startup is not great, with some
hard x-rays.

Next shot: reduce Btor by 2% (from 4.58 to 4.50 T)
Jun 10 2003 11:27:41:213AM1030610008Robert GranetzShot 08 -- Plasma. Good shot. Btor=4.50 T. No TCI data (camac problem), so
no ne peaking, but x-ray width indicates that ITB's formed before
the H-L back transitions, finally! Prf=0.9+1.5+~0=2.4 MW.
One of the TF joints is showing a high temperature.

Next shot: TF-only test shot (5.4 T) to check joint temperature.
Jun 10 2003 11:34:20:447AM1030610009Robert GranetzShot 09 -- Test. 5.4 tesla TF-only shot to check joint resistance. Seems
to be okay on the TF scanner.

Next shot: back to plasma operation
Jun 10 2003 11:52:52:780AM1030610010Robert GranetzShot 10 -- Plasma. Good shot. Btor=4.51 T. No H-mode ITB's.
Prf=0.9+1.4+1.1=3.4 MW. H/D=4-6%.

Next shot: no PCS changes.
Jun 10 2003 12:06:49:727PM1030610011Robert GranetzShot 11 -- Plasma. Good shot. Prf=3.3 MW. No H-mode ITB's. H/D=6%.

Next shot: raise density another 10%.
Jun 10 2003 12:27:20:610PM1030610012Robert GranetzShot 12 -- Plasma. Good shot. nl_04=1.1e20 m-2. Prf=0+1.5+0=1.5 MW, so
only got one H-mode. Great startup; no hard x-rays.

Next shot: no PCS changes.
Jun 10 2003 12:36:05:283PM1030610013Robert GranetzShot 13 -- Plasma. Good shot. Prf=1.0+1.5+0=2.5 MW. H/D=4-6%. Good startup.
Nl H-mode ITB's.

Next shot: no PCS changes.
Jun 10 2003 12:48:49:743PM1030610014Robert GranetzShot 14 -- Plasma. Good shot. Got a good ITB on the 2nd H-mode! Good
startup. Prf=0.9+1.4+1.1=3.4 MW. H/D=4-5%.

Next shot: reduce Btor by another 1% (I_TF=121500 A)). Increase
argon puff by another 10 ms.
Jun 10 2003 12:58:59:983PM1030610015Robert GranetzShot 15 -- Plasma. Good shot. No H-mode ITB's Prf=0.9+1.4+1.1=3.4 MW.
H/D=4-6%. Good startup.

Next shot: add the 1% back to Btor.
Jun 10 2003 01:12:11:197PM1030610016Robert GranetzShot 16 -- Plasma. Good shot. Got another ITB on the final H-mode!
Prf=1.0+1.4+1.0=3.4 MW. H/D=4-6%. Good startup.

Next shot: no PCS changes.
Jun 10 2003 01:29:24:290PM1030610018Robert GranetzShot 17 -- Plasma. Good shot. Got another ITB on the final H-mode.
Prf=1.0+1.4+1.0=3.4 MW. H/D=4-6%. Good startup.

Next shot: no PCS changes.
Jun 10 2003 01:42:48:083PM1030610018Robert GranetzShot 18 -- Plasma. Good shot. Another H-mode ITB, but not as clear as the
previous ones today. Prf=1.0+1.4+1.0=3.4 MW. H/D=6%.

Next shot: no PCS changes. The DNB is firing at t=1.35 s.
Jun 10 2003 01:59:47:460PM1030610019Robert GranetzShot 19 -- Plasma. Good shot. Bad startup, lots of hard x-rays. TCI failed
on channel 4. Density feedback failed. J-port RF dropped out
early. No ITBs.

Next shot: go to other half of the MP. Raise Bt to 6.4 T, Ip
to 0.9 MA. Decrease density to nl_04=0.8e20 m-2.
Jun 10 2003 02:29:31:500PM1030610020Robert GranetzShot 20 -- Plasma. Full-length shot, but TF crowbarred. Bt=6.4 T, Ip=0.9 MA.
TCI failed again -- no feedback, so density was too high.
Prf=3.3 --> 2 --> 1 MW. Multiple H-modes, but no ITB's. The
paragon server node crashed, so all of the paragon PC's will have
to be rebooted before the next shot. The DNB suddenly developed
a problem with the beam current signal.

Next shot: TF-only test.
Jun 10 2003 03:03:31:863PM1030610021Robert GranetzShot 21 -- Test. TF-only, 50 kA. OK

Next shot: 150 kA TF-only test.
Jun 10 2003 03:33:25:360PM1030610022Robert GranetzShot 22 -- No power. Should have been a 150 kA TF-only test.

Next shot: 150 kA TF-only test.
Jun 10 2003 03:39:43:603PM1030610023Robert GranetzShot 23 -- Test. TF-only, 150 kA. OK

Next shot: back to 6.4 T plasma operation
Jun 10 2003 04:33:20:363PM1030610024Robert GranetzShot 24 -- Plasma. Good shot, but the TF crowbarred again. BT=6.4 T,
Ip=0.9 MA, Prf=~0 + 1.4+1.1=2.5 MW. H/D=7%. I think this
had a long ITB (from 1.3 to 1.5 s) during the H-mode, judging
from the x-ray peaking. Dmitri reports that the Thomson shows
a very small diameter peaked region.

Next shot: 50 kA TF-only test.
Jun 10 2003 04:34:27:977PM1030610025Robert GranetzShot 25 -- Test. 50 kA TF-only test. OK

Next shot: plasma, with Bt=5.4 T, Ip=0.8 MA
Jun 10 2003 04:51:03:773PM1030610026Robert GranetzShot 26 -- Plasma. Good shot. Btor=5.4 T, Ip=0.8 MA, nl (target) = 0.9e20 m-2
Prf=0.5+1.4+1.1=3.0 MW. H/D=6-8%. H-modes, no ITBs.

Next shot: get a start on tomorrow's run. Load segment 2 from
1030529016, except reduce nl_04 to 1.0e20 m-2, and turn on the
A-coils in the normal suppression configuration. Bt=5.4 T,
Ip=1.0 MA.
Jun 10 2003 05:14:29:317PM1030610027Robert GranetzShot 27 -- Plasma. Good shot. Bt=5.4, Ip=1.0 MA, nl(target)=1.1e20 m-2, and
Prf=3.0-3.6 MW. Lots of short (ELM-free?) H-modes. Startup was
bad though.

End of run.
Jun 10 2003 05:15:18:130PM1030610027Robert GranetzPhysics operator summary for run 1030610 (Tuesday):

MP 303 - High Performance ITB's

Session leader: J. Rice
Physics operator: R. Granetz
Engineers in charge:

Summary: We got some short H-mode ITB's with inboard-side resonance on
shots 14, 16, 17, and 18 (4.5 T, 0.8 MA, Prf=3.4 MW). We then
switched to 6.4 T to do outboard-side resonance on shots 20 and
24. We got full-length plasmas on both shots, but the TF
crowbarred both times, necessitating long delays and multiple
TF-only test shots. Nevertheless, I think shot 24 had a long
ITB (t=1.3-1.5 s). The x-ray profile was very narrow, and the
Thomson profiles were peaked, but over a very small radius
(consistent with John Rice's previous observations.)

Other than the crowbars, the machine ran well. There were no
fizzles or duds, and all shots had full rampdowns. There were no
disruptions. After shot 20, the network server for the paragon
stations crashed, necessitating a reboot of all the paragon
stations.

Scorecard: 21 plasmas
0 fizzles
0 duds
6 test or no-power shot cycle
0 aborted and/or screwed up by computer problems
----------
27 total
Jun 11 2003 10:19:22:023AM1030610028Joseph SnipesShot 28: Copied shot 1030610027 but changed ZXU and RXU to reproduce 1001013002, which had lower upper
triangularity. Also increased CLEARIN by 0.005 m at 0.43 s to attempt to avoid touching the
inner wall at crossover. Good shot with several H-modes.
Jun 11 2003 10:21:15:853AM1030610028Joseph SnipesShot 28: Copied shot 1030610027 but changed ZXU and RXU to reproduce 1001013002, which had lower upper
triangularity. Also increased CLEARIN by 0.005 m at 0.43 s to attempt to avoid touching the
inner wall at crossover. Good shot with several H-modes. Due to a Josh error, the first shot
of 1030611 was written as 1030610028.

Engineering Operator Comments
ShotTimeTypeStatusComment
108:58:31:303AMPlasmaOk
209:17:16:810AMPlasmaOk
309:41:24:980AMPlasmaOk
409:55:26:850AMPlasmaOk
510:22:34:323AMPlasmaOk
610:45:45:917AMPlasmaOk
710:59:59:410AMPlasmaOk
811:13:21:390AMPlasmaOk
911:27:45:353AMTestOkTF Joint Resistance Test
1011:41:55:100AMPlasmaOk
1111:55:09:877AMPlasmaOk
1212:09:49:263PMPlasmaOk
1312:23:22:383PMPlasmaOk
1412:36:48:283PMPlasmaOk
1512:49:48:370PMPlasmaOk
1601:03:08:133PMPlasmaOk
1701:16:17:080PMPlasmaOk
1801:29:16:963PMPlasmaOk
1901:46:10:790PMPlasmaOk
2002:04:05:000PMPlasmaBadTF type 1
2102:58:27:103PMTestOkTF 50ka test
2203:15:47:073PMTestOkNO TF
2303:35:25:160PMTestOkTF 150kA
2403:48:14:853PMPlasmaBadTF self powered circuit fired
2504:28:27:103PMTestOk
2604:39:47:750PMPlasmaOk
2704:54:38:123PMPlasmaOk
2810:15:40:603AMPlasmaOk