| Session leader(s): | Olaf Grulke,Dmitri Mossessian |
| Physics operator(s): | Dmitri Mossessian |
| Engineering operator(s): | Unknown |
| Engineering Operator Run Comment |
| MP#332 Turbulence (L-mode data); SL Grulke; PO Mossessian; EO Dekow/Fitz |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:33:147PM |
| Author: Dmitri Mossessian |
| un summary for the first half of 1030613 - MP282, driving ELMs with current ramp We had only 10 shots on 1030612, when this MP was originally scheduled, because of some computer problems, and we continued on the 13th where we stopped on 12th. We had 10 shots scheduled for today, but this turned out to be enough to prove that ELMs can be driven on C-Mod by a current ramp. On the other hand, the results that we obtained can only be considered as an indication of that possibility, rather than a definite prove that the peeling/ballooning theory works here. In short, we did see high frequency fluctuations in D-alpha signal that appear when plasma current is ramped up and do not show up in an identical shot without the current ramp. PCI diagnostic showed that these fluctuations interrupt the QC mode at the edge. We have yet to look at the magnetics to see if we can identify some ELMs precursors there. The fluctuations occur, as it was expected, at high pedestal temperature, low density and low triangularity. We did not have a chance to do a careful shape scan to see if weak shaping is better for ELMs, as the theory suggests. The pedestal temperatures that we were able to obtain were quite low for given RF power (4 - 5 MW) and target density (6-5e20) - generally less than 600 eV. The preliminary conclusion therefore would be that ELMs can be triggered by fast current ramp but generally require pedestal temperature higher, and collisionality lower than was achieved. The experiment should be repeated when better RF coupling and higher plasma temperatures will be achievable to carry out the pedestal temperature scan between 500 and 1000 eV and observe changes in ELMs behavior. Details: ---------------------------------------------------------------------------- 1030613001 mossessian PHYSICS_OPERATOR Jun 13 2003 9:06:50:760AM . . . . . . . . . . . . . . . . . . . . No power shot - Josh is working on some software Next shot - try plasma ---------------------------------------------------------------------------- 1030613002 mossessian PHYSICS_OPERATOR Jun 13 2003 9:36:23:310AM . . . . . . . . . . . . . . . . . . . . Good H-mode. Only 1.3 MW of RF. No current ramp effect. Next shot - try full RF power. Drop upper triangularity (RXU out 1 cm) and elongation (ZXU up 1 cm) ---------------------------------------------------------------------------- 1030613004 mossessian PHYSICS_OPERATOR Jun 13 2003 9:57:35:070AM . . . . . . . . . . . . . . . . . . . . RF not steady. Plasma disrupted after current ramp due to large injection (caused by RF ?) Next shot - move beginning of RF to 0.9 s to get hotter H-mode into current ramp. Reduce upper delta some more (RXU + 1cm). Add 2 mm ramp to RCUR at .95 s to try to compensate for current ramp effect ---------------------------------------------------------------------------- 1030613005 mossessian PHYSICS_OPERATOR Jun 13 2003 10:09:45:630AM . . . . . . . . . . . . . . . . . . . . RF trips a lot. Next shot - plasma seems to be stable enough and we will try to increase current ramp rate somewhat. RXU + 1cm Add 3 mm to RCUR to increase right gap a little ---------------------------------------------------------------------------- 1030613006 mossessian PHYSICS_OPERATOR Jun 13 2003 10:18:49:496AM . . . . . . . . . . . . . . . . . . . . Good shot. Steady RF at 3.5 MW, Te_ped ~ 500 eV, good current rise. definitely no ELMs driven Next shot - lower target density to 5e19 ---------------------------------------------------------------------------- 1030613007 mossessian PHYSICS_OPERATOR Jun 13 2003 10:29:59:400AM . . . . . . . . . . . . . . . . . . . . Good shot. Target 6e19. Te_ped ~ 500 eV. Burst of ELMs between 1 and 1.04 s. Next shot - turn current ramp OFF ---------------------------------------------------------------------------- 1030613008 mossessian PHYSICS_OPERATOR Jun 13 2003 10:51:42:830AM . . . . . . . . . . . . . . . . . . . . Good shot. Repeats shot 7 but grassy ELMs disappear. Try to increase the effect on next couple of shots - increase RF power and drop upper delta more. Next shot - RXU + 1cm, current ramp on. Increase current ramp rate - now ramping to .85 MA ---------------------------------------------------------------------------- 1030613009 mossessian PHYSICS_OPERATOR Jun 13 2003 10:58:38:853AM . . . . . . . . . . . . . . . . . . . . Decreasing upper delta seems to make things worse - almost no effect of current ramp seen on D-alpha. Next shot - RXU -2 cm ---------------------------------------------------------------------------- 1030613010 mossessian PHYSICS_OPERATOR Jun 13 2003 11:16:13:750AM . . . . . . . . . . . . . . . . . . . . Lost density feedback in the middle of the shot. Got max gas puff right from the beginning of H-mode. After H-L transition density was rising and plasma disrupted at 1.46 s Next shot - repeat with higher current ramp rate. PG4 from 23 to 21 ms ---------------------------------------------------------------------------- 1030613011 mossessian PHYSICS_OPERATOR Jun 13 2003 11:26:11:696AM . . . . . . . . . . . . . . . . . . . . Better than 10 although still disrupted. ELMs seem to be there during Ip ramp. |
| Entered: Jul 7 2004 03:49:33:180PM |
| Author: Olaf Grulke |
| Run summary for the second half of 1030613 From: Olaf Grulke Date: Tue, 17 Jun 2003 13:35:11 -0400 This run is to used to carry out the non-piggyback ohmic part of MP 332. The idea was to make a simultaneous spatiotemporal measurement of plasma density and plasma potential fluctuations. This is done by establishing a magnetic mapping between the observation region of the GPI system and the F-probe. This mapping occurs when Bt=5.4 T and I_p=610 kA. We measured cross-correlation between I-sat and V-floating signals of the F-port probe and the light fluctuations on the radial array of GPI views over a L-mode density scan. We also took movies of GPI viewing region using the PSI camera. We also tried to look during EDA H-mode, but were unsuccessful in making an EDA H-mode. Plan: 1) setup a shot with the correct magnetic mapping from the FSP to the GPI viewing region (Bt=5.4 T, Ip=600kA with NL_04=0.8e20 2) decrease the density on subsequent shots in increments of 0.2e20, to NL_04=0.4e20 3) then take shots with density of 1.1e20, and then 1.3e20 4) proceed to making EDA H-modes with ~2MW of RF at a density chosen based on above density scan We desire the following diagnostics: FSP ASP GPI cameras GPI fast diode array NINJA gas-puffing from A-B limiter edge TS Dalsa for edge density RESULTS: 1) We successfully completed the L-mode density scan. The somewhat surprising result is that the probe-diode correlation DECREASED to small values at densities NL_04<0.7e20 indicating that collisionality is not the major influence on the parallel correlation of fluctuations. 2) We found that at densities NL_04<0.7e20 the plasma created by recycling off of the probe body in the far-SOL maps (with some cross-field spreading)along the local flux tube. The observational evidence for this was the appearance of plasma in the far-SOL regions viewed by the diodes when the probe is inserted, but only when the probe maps magnetically to the diode-viewing region. 3) The probe-diode correlation is 30-45% at densities (NL_04) between 1 and 1.3e20.In this range the cross-correlation between diode and floating potential has a "dipole" structure, positive for negative lag times and negative for positive lag times. This result is consistent findings at other fusion devices as stellarators and tokamaks and maybe a result of the conventional picture of vortices convecting plasma across the plasma pressure gradient and thereby causing plasma density fluctuations. The shot by shot summary follows: Begin MP 332 with shot 1030613012 012 - I_p=600 kA and target NL_04=0.7e20. Use this shot to test the plamas target for probe insertion. Timings of fluctuation diagnostics are for looking at 0.8 sec, i.e. PSI @ 0.8 sec diodes starting at 0.75s, thru 0.878 s NINJA puff trigger at 0.6 s open for 0.15 s Good shot. 013 - request: I_p=600 kA and target NL_04=0.7e20. actual NL_04=0.8e20 1st F-probe insertion at 0.8 s. 014 - repeat actual NL_04=0.8e20 good plasma 015 - drop density request: NL_04=0.5e20 actual NL_04=0.65e20 @ 0.8 s good plasma 016 - request: NL_04=0.5e20 actual NL_04=0.65e20 @ 0.8 s good plasma 017- go to lower density request: NL_04=0.4e20 actual NL_04=0.60e20 @ 0.8 s good plasma See clear evidence of probe insertion on the diode signals. The probe-diode correlations are not good - 20% at maximum. The far-SOL viewing channels see a strong increase in emission, while the channels viewing inside the separatrix see a decrease in emission. Possible explanation is that the probe creates local plasma via recycling. That plasma maps to the diode views, but spreads perppendiclual to the field as well. The reson for the decrease in emission for the inside channels may be shadowing by this increase in far-SOL plasma. 018 - repeat 017 disrupted 019 - repeat 017 request: NL_04=0.4e20 actual NL_04=0.56e20 @ 0.8 s good plasma Poor probe-diode correlation. Again see clear evidence of probe-created plasma in the far-SOL and shadowing for the views inside the separatrix. 020 - drop density request: NL_04=0.3e20 actual NL_04=0.49e20 @ 0.8 s good plasma Poor probe-diode correlation. Again see clear evidence of probe-created plasma in the far-SOL and shadowing for the views inside the separatrix. When the PSI triggers at 0.8 s, it sees the plasma in the far-SOL, i.e. the blobs are close to the nozzle 021 - repeat 020 request: NL_04=0.3e20 actual NL_04=0.48e20 @ 0.8 s good plasma Poor probe-diode correlation. Again see clear evidence of probe-created plasma in the far-SOL and shadowing for the views inside the separatrix. Moved PSI trigger to 0.785,i.e. before the probe-created plasma is in the diode f-of-v. The emission (with blobs) move inward, closer to the separatrix. 022 - repeat 021, but with higher I_p (800 kA). This will destroy the mapping between probe and diodes. request: NL_04=0.5e20 actual NL_04=0.68e20 @ 0.8 s good plasma No probe-diode correlation, as expected. No probe-created plasma seen be diodes, confirming the hypotheses that the probe creates the far-SOL plasma seen on the diodes and that that plasma is local, mapping with the flux tube. PSI trigger still 0.785. 023 - no power shot 024 - request higher denity, back to I_p=600 kA for which probe diode mapping exists. MARFE - disrupts 025 - try again, this time ramping the density. request: NL_04=1.0e20 actual NL_04=1.1e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. PSI trigger at 0.785. 026 - repeat 025 request: NL_04=1.0e20 actual NL_04=1.1e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. PSI trigger at 0.785. 027 - go to higher density request: NL_04=1.1e20 actual NL_04=1.18e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. See classic "dipole" effect on the diode-probe correlation function. PSI trigger at 0.785. 028 - repeat 027 request: NL_04=1.1e20 actual NL_04=1.18e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. See classic "dipole" signature on the diode-probe correlation function. PSI trigger at 0.795, the time of maximum correlation. 029 - go to slightly higher density request: NL_04=1.2e20 actual NL_04=1.25e20 @ 0.8 s good plasma Still "good" (0.3-0.4) probe-diode correlation. See classic "dipole" signature on the diode-probe correlation function. PSI trigger at 0.795, the time of maximum correlation. 030 - fizzle 031 - repeat of 029 request: NL_04=1.2e20 actual NL_04=1.28e20 @ 0.8 s good plasma Still "good" (0.3-0.4) probe-diode correlation. See classic "dipole" signature on the diode-probe correlation function. PSI trigger at 0.795, the time of maximum correlation. 032 - fizzle 033 - fill in density point around 0.95e20 request: NL_04=0.85e20 actual NL_04=1.0e20 @ 0.8 s good plasma Still "good" (0.3-0.4) probe-diode correlation. 034 - go to EDA H-mode part of the MP request: NL_04=0.85e20, RF power stepped from 1.5 to 2.0 MW at 1. sec actual: NL_04=1.1e20, RF tripped, no H-modes timings are still all set around 0.8 s 035 - try to repeat with RF staying on request: NL_04=0.85e20, RF power stepped from 1.5 to 2.0 MW at 1. sec actual: NL_04=1.1e20, RF tripping, no H-modes timings are still all set around 0.8 s 036 fizzle |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:18:363PM |
| Author: Dmitri Mossessian |
Physop summary for 1030613 PO Mossessian SL Mossessian (MP282), Gurke (MP332) Summary: Good run. We started by continuing MP282 that we did not finish yesterday because of very long delay due to computer problems. After 10 shots we switched to MP332. Plasma ran well. Startup varies. Sometimes current rise is very ugly and there is a strong hesitation, but it survived most of the times - at least untill I tried to fix it. My attempts to fix the current rise by changing gas puff led to several fizzles at the end of the run. In general, if PO does not touch the startup current rise is very smooth in half of the shots. Various changes were done to PCS shot programming in segment 2 - see details below for details. Total: 36 shots 2 tests 3 fizzles Details: ---------------------------------------------------------------------------- 1030613001 mossessian PHYSICS_OPERATOR Jun 13 2003 9:06:50:760AM . . . . . . . . . . . . . . . . . . . . No power shot - Josh is working on some software Next shot - try plasma ---------------------------------------------------------------------------- 1030613002 mossessian PHYSICS_OPERATOR Jun 13 2003 9:36:23:310AM . . . . . . . . . . . . . . . . . . . . Good H-mode. Only 1.3 MW of RF. No current ramp effect. Next shot - try full RF power. Drop upper triangularity (RXU out 1 cm) and elongation (ZXU up 1 cm) ---------------------------------------------------------------------------- 1030613004 mossessian PHYSICS_OPERATOR Jun 13 2003 9:57:35:070AM . . . . . . . . . . . . . . . . . . . . RF not steady. Plasma disrupted after current ramp due to large injection (caused by RF ?) Next shot - move beginning of RF to 0.9 s to get hotter H-mode into current ramp. Reduce upper delta some more (RXU + 1cm). Add 2 mm ramp to RCUR at .95 s to try to compensate for current ramp effect ---------------------------------------------------------------------------- 1030613005 mossessian PHYSICS_OPERATOR Jun 13 2003 10:09:45:630AM . . . . . . . . . . . . . . . . . . . . RF trips a lot. Next shot - plasma seems to be stable enough and we will try to increase current ramp rate somewhat. RXU + 1cm Add 3 mm to RCUR to increase right gap a little ---------------------------------------------------------------------------- 1030613006 mossessian PHYSICS_OPERATOR Jun 13 2003 10:18:49:496AM . . . . . . . . . . . . . . . . . . . . Good shot. Steady RF at 3.5 MW, Te_ped ~ 500 eV, good current rise. definitely no ELMs driven Next shot - lower target density to 5e19 ---------------------------------------------------------------------------- 1030613007 mossessian PHYSICS_OPERATOR Jun 13 2003 10:29:59:400AM . . . . . . . . . . . . . . . . . . . . Good shot. Target 6e19. Te_ped ~ 500 eV. Burst of ELMs between 1 and 1.04 s. Next shot - turn current ramp OFF ---------------------------------------------------------------------------- 1030613008 mossessian PHYSICS_OPERATOR Jun 13 2003 10:51:42:830AM . . . . . . . . . . . . . . . . . . . . Good shot. Repeats shot 7 but grassy ELMs disappear. Try to increase the effect on next couple of shots - increase RF power and drop upper delta more. Next shot - RXU + 1cm, current ramp on. Increase current ramp rate - now ramping to .85 MA ---------------------------------------------------------------------------- 1030613009 mossessian PHYSICS_OPERATOR Jun 13 2003 10:58:38:853AM . . . . . . . . . . . . . . . . . . . . Decreasing upper delta seems to make things worse - almost no effect of current ramp seen on D-alpha. Next shot - RXU -2 cm ---------------------------------------------------------------------------- 1030613010 mossessian PHYSICS_OPERATOR Jun 13 2003 11:16:13:750AM . . . . . . . . . . . . . . . . . . . . Lost density feedback in the middle of the shot. Got max gas puff right from the beginning of H-mode. After H-L transition density was rising and plasma disrupted at 1.46 s Next shot - repeat with higher current ramp rate. PG4 from 23 to 21 ms ---------------------------------------------------------------------------- 1030613011 mossessian PHYSICS_OPERATOR Jun 13 2003 11:26:11:696AM . . . . . . . . . . . . . . . . . . . . Better than 10 although still disrupted. ELMs seem to be there during Ip ramp. This ends MP 282 Next shot - go to MP 332. Load segment 2 from 1030604010. ---------------------------------------------------------------------------- 1030613012 mossessian PHYSICS_OPERATOR Jun 13 2003 11:44:37:780AM . . . . . . . . . . . . . . . . . . . . Plasma. nl=0.8e20, asked for 0.7e20. Next shot - CLEARIN down 5 mm ---------------------------------------------------------------------------- 1030613013 mossessian PHYSICS_OPERATOR Jun 13 2003 11:59:29:486AM . . . . . . . . . . . . . . . . . . . . Plasma. After F-probe plunge at 0.8 s edge cools down to 0 eV at 0.85 for 150 ms. Next shot - add 10 ms to Ar (PG1). CLEARIN down 3 mm ---------------------------------------------------------------------------- 1030613014 mossessian PHYSICS_OPERATOR Jun 13 2003 12:06:37:540PM . . . . . . . . . . . . . . . . . . . . Plasma Next shot - nl -> 5e19 ---------------------------------------------------------------------------- 1030613016 mossessian PHYSICS_OPERATOR Jun 13 2003 12:32:33:696PM . . . . . . . . . . . . . . . . . . . . Plasma Next shot - nl -> 4e19 ---------------------------------------------------------------------------- 1030613015 mossessian PHYSICS_OPERATOR Jun 13 2003 12:32:43:570PM . . . . . . . . . . . . . . . . . . . . Plasma Next shot - no changes ---------------------------------------------------------------------------- 1030613017 mossessian PHYSICS_OPERATOR Jun 13 2003 12:48:20:556PM . . . . . . . . . . . . . . . . . . . . Plasma Next shot - CLEARIN + 2mm ---------------------------------------------------------------------------- 1030613018 mossessian PHYSICS_OPERATOR Jun 13 2003 1:00:42:416PM . . . . . . . . . . . . . . . . . . . . Plasma. Disrupted at .3 s - lost TCI feedback Next shot - no changes ---------------------------------------------------------------------------- 1030613019 mossessian PHYSICS_OPERATOR Jun 13 2003 1:12:55:163PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - nl-> 3e19 ---------------------------------------------------------------------------- 1030613021 mossessian PHYSICS_OPERATOR Jun 13 2003 1:45:10:110PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - nl -> 5e19 Ip -> 0.8 MA ---------------------------------------------------------------------------- 1030613022 mossessian PHYSICS_OPERATOR Jun 13 2003 1:59:28:686PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - nl -> 1e20 Ip -> 0.6 MA ---------------------------------------------------------------------------- 1030613023 mossessian PHYSICS_OPERATOR Jun 13 2003 2:05:20:553PM . . . . . . . . . . . . . . . . . . . . No power shot. EF troubles ---------------------------------------------------------------------------- 1030613024 mossessian PHYSICS_OPERATOR Jun 13 2003 2:29:02:190PM . . . . . . . . . . . . . . . . . . . . Plasma killed by giant MARFE that starts around 0.5 s. Next shot - slow down density rise to bring it to 1e20 by 0.8 s ---------------------------------------------------------------------------- 1030613025 mossessian PHYSICS_OPERATOR Jun 13 2003 2:39:49:453PM . . . . . . . . . . . . . . . . . . . . Good shot Next shot - no change ---------------------------------------------------------------------------- 1030613026 mossessian PHYSICS_OPERATOR Jun 13 2003 3:08:12:860PM . . . . . . . . . . . . . . . . . . . . Good shot Next shot - nl -> 1.1e20 ---------------------------------------------------------------------------- 1030613027 mossessian PHYSICS_OPERATOR Jun 13 2003 3:08:22:220PM . . . . . . . . . . . . . . . . . . . . Good shot Next shot - no change ---------------------------------------------------------------------------- 1030613028 mossessian PHYSICS_OPERATOR Jun 13 2003 3:13:22:473PM . . . . . . . . . . . . . . . . . . . . Good shot Next shot - nl -> 1.2e20 ---------------------------------------------------------------------------- 1030613029 mossessian PHYSICS_OPERATOR Jun 13 2003 3:28:32:740PM . . . . . . . . . . . . . . . . . . . . Good shot Next shot - no change ---------------------------------------------------------------------------- 1030613030 mossessian PHYSICS_OPERATOR Jun 13 2003 3:48:51:876PM . . . . . . . . . . . . . . . . . . . . Fizzle. Current rise too fast Next shot - add 3 ms to PG4 21 -> 24 ms ---------------------------------------------------------------------------- 1030613031 mossessian PHYSICS_OPERATOR Jun 13 2003 3:55:14:146PM . . . . . . . . . . . . . . . . . . . . Plasma. Next shot - nl-> 0.85e20, add 2 ms to PG4 ---------------------------------------------------------------------------- 1030613032 mossessian PHYSICS_OPERATOR Jun 13 2003 4:11:50:090PM . . . . . . . . . . . . . . . . . . . . Fizzle. Too much gas Next shot - reduce PG4 (-3 ms) ---------------------------------------------------------------------------- 1030613033 mossessian PHYSICS_OPERATOR Jun 13 2003 4:21:52:100PM . . . . . . . . . . . . . . . . . . . . Plasma. Very bad startup Next shot - nl -> 1e20 ---------------------------------------------------------------------------- 1030613034 mossessian PHYSICS_OPERATOR Jun 13 2003 4:32:01:363PM . . . . . . . . . . . . . . . . . . . . Plasma. Startup is good. No H-mode - poor RF matching Next shot -repeat ---------------------------------------------------------------------------- 1030613036 mossessian PHYSICS_OPERATOR Jun 13 2003 4:59:09:970PM . . . . . . . . . . . . . . . . . . . . Fizzle ---------------------------------------------------------------------------- 1030613xxx mossessian PHYSICS_OPERATOR Jun 13 2003 8:58:17:296AM . . . . . . . . . . . . . . . . . . . . Comntinue yesterday's runa (MP282). For details see SESSION LEADER logbook entries for yesterday. Load 1030612006. RF from .7 s, 4 MW - attempt to repeat shots 6 taht had large ELMs driven by current |
| Session Leader Comments | |||
| Jun 13 2003 02:31:08:757PM | Jim Terry | This run is to used to carry out the non-piggyback part of MP 332. The idea is to make a simultaneous spatiotemporal measurement of plasma density and plasma potential fluctuations. This is done by estaablishing a magnetic mapping between the observation region of the GPI system and the F-probe. This mapping occurs when Bt=5.4 T and I_p=610 kA. We will be measuring the magnitude and delay of the cross-correlation between I-sat and V-floating signals on the probe and the light fluctuations on the radial array of GPI views under a variety of plasma conditions: Ohmic L-mode density scan RF-heated EDA H-mode RF-heated ELM-free H-mode Plan: 1) setup by loading shot 1030604016, with NL_04=1e20 2) decrease the density on subsequent shots in increments of 0.2e20, to NL_04=0.4e20 3) then take two shots with density of 1.2e20, and then 1.4e20 4) proceed to making EDA H-modes with ~3MW of RF at a density chosen based on above density scan 5) if time allows, reduce the density to make ELM-free H-modes In each of these conditions we will be measuring the cross-correlation between I-sat and V-floating signals on the probe and the light fluctuations on the radial array of GPI views, as well as taking movies of the GPI vieewing region with the PSI camera. We desire the following diagnostics: FSP ASP GPI cameras GPI fast diode array NINJA gas-puffing from A-B limiter edge TS Dalsa for edge density profiles This part of the run began on shot 103613012 | |
| Jun 13 2003 02:36:51:433PM | 1030613012 | Jim Terry | Begin MP 332 with I_p=600 kA and target NL_04=0.7e20. Use this shot to test the plamas target for probe insertion. Timings of fluctuation diagnostics are for looking at 0.8 sec, i.e. PSI @ 0.8 sec diodes starting at 0.75s, thru 0.878 s NINJA puff trigger at 0.6 s open for 0.15 s Good shot. |
| Jun 13 2003 02:41:45:923PM | 1030613013 | Jim Terry | request: I_p=600 kA and target NL_04=0.7e20. actual NL_04=0.8e20 1st F-probe insertion at 0.8 s. |
| Jun 13 2003 02:43:13:487PM | 1030613014 | Jim Terry | repeat actual NL_04=0.8e20 good plasma |
| Jun 13 2003 02:44:38:770PM | 1030613015 | Jim Terry | drop density request: NL_04=0.5e20 actual NL_04=0.65e20 @ 0.8 s good plasma |
| Jun 13 2003 02:45:23:943PM | 1030613016 | Jim Terry | repeat of 015 request: NL_04=0.5e20 actual NL_04=0.65e20 @ 0.8 s good plasma |
| Jun 13 2003 02:55:20:797PM | 1030613017 | Jim Terry | go to lower density request: NL_04=0.4e20 actual NL_04=0.60e20 @ 0.8 s good plasma See clear evidence of probe insertion on the diode signals. The probe-diode correlations are not good - 20% at maximum. The far-SOL viewing channels see a strong increase in emission, while the channels viewing inside the separatrix see a decrease in emission. Possible explanation is that the probe creates local plasma via recycling. That plasma maps to the diode views, but spreads perppendiclual to the field as well. The reson for the decrease in emission for the inside channels may be shadowing by this increase in far-SOL plasma. |
| Jun 13 2003 02:58:17:630PM | 1030613018 | Jim Terry | repeat 017 disrupted |
| Jun 13 2003 03:01:36:743PM | 1030613019 | Jim Terry | repeat 017 request: NL_04=0.4e20 actual NL_04=0.56e20 @ 0.8 s good plasma Poor probe-diode correlation. Again see clear evidence of probe-created plasma in the far-SOL and shadowing for the views inside the separatrix. |
| Jun 13 2003 03:06:01:827PM | 1030613020 | Jim Terry | drop density request: NL_04=0.3e20 actual NL_04=0.49e20 @ 0.8 s good plasma Poor probe-diode correlation. Again see clear evidence of probe-created plasma in the far-SOL and shadowing for the views inside the separatrix. When the PSI triggers at 0.8 s, it sees the plasma in the far-SOL, i.e. the blobs are close to the nozzle |
| Jun 13 2003 03:07:51:390PM | 1030613021 | Jim Terry | repeat 020 request: NL_04=0.3e20 actual NL_04=0.48e20 @ 0.8 s good plasma Poor probe-diode correlation. Again see clear evidence of probe-created plasma in the far-SOL and shadowing for the views inside the separatrix. Moved PSI trigger to 0.785,i.e. before the probe-created plasma is in the diode f-of-v. The emission (with blobs) move inward, closer to the separatrix. |
| Jun 13 2003 03:22:47:487PM | 1030613022 | Jim Terry | repeat 021, but with higher I_p (800 kA). This will destroy the mapping between probe and diodes. request: NL_04=0.5e20 actual NL_04=0.68e20 @ 0.8 s good plasma No probe-diode correlation, as expected. No probe-created plasma seen be diodes, confirming the hypotheses that the probe creats the far-SOL plasma seen on the diodes and that that plasma is local, mapping with the flux tube. PSI trigger still 0.785. |
| Jun 13 2003 03:30:32:870PM | 1030613023 | Jim Terry | no power shot |
| Jun 13 2003 03:30:12:277PM | 1030613024 | Jim Terry | request higher denity, back to I_p=600 kA for which probe diode mapping exists. MARFE - disrupts |
| Jun 13 2003 03:29:44:697PM | 1030613025 | Jim Terry | try again, this time ramping the density. request: NL_04=1.0e20 actual NL_04=1.1e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. PSI trigger at 0.785. |
| Jun 13 2003 03:32:09:387PM | 1030613026 | Jim Terry | repeat 025 request: NL_04=1.0e20 actual NL_04=1.1e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. PSI trigger at 0.785. |
| Jun 13 2003 03:34:18:483PM | 1030613027 | Jim Terry | go to higher density request: NL_04=1.1e20 actual NL_04=1.18e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. See classic "dipole" effect on the diode-probe correlation function. PSI trigger at 0.785. |
| Jun 13 2003 03:39:11:943PM | 1030613028 | Jim Terry | repeat 027 request: NL_04=1.1e20 actual NL_04=1.18e20 @ 0.8 s good plasma regained "good" (0.3-0.4) probe-diode correlation. See classic "dipole" signature on the diode-probe correlation function. PSI trigger at 0.795, the time of maximum correlation. |
| Jun 13 2003 03:43:10:590PM | 1030613029 | Jim Terry | go to slightly higher density request: NL_04=1.2e20 actual NL_04=1.25e20 @ 0.8 s good plasma Still "good" (0.3-0.4) probe-diode correlation. See classic "dipole" signature on the diode-probe correlation function. PSI trigger at 0.795, the time of maximum correlation. |
| Jun 13 2003 03:44:02:573PM | 1030613030 | Jim Terry | repeat of 029 fizzle |
| Jun 13 2003 04:25:21:887PM | 1030613031 | Jim Terry | repeat of 029 request: NL_04=1.2e20 actual NL_04=1.28e20 @ 0.8 s good plasma Still "good" (0.3-0.4) probe-diode correlation. See classic "dipole" signature on the diode-probe correlation function. PSI trigger at 0.795, the time of maximum correlation. |
| Jun 16 2003 08:54:32:327AM | 1030613032 | Jim Terry | fizzle |
| Jun 13 2003 04:24:07:340PM | 1030613033 | Jim Terry | go to lower density to fill in the "turn-on" of the probe-diode correlation. request: NL_04=0.85e20 actual NL_04=1.0e20 @ 0.8 s good plasma poorer (0.15-0.25) probe-diode correlation. PSI trigger at 0.795, the time of maximum correlation. |
| Jun 16 2003 08:59:16:617AM | 1030613033 | Jim Terry | fill in density point around 0.95e20 request: NL_04=0.85e20 actual NL_04=1.0e20 @ 0.8 s good plasma Still "good" (0.3-0.4) probe-diode correlation. |
| Jun 13 2003 04:34:50:007PM | 1030613034 | Jim Terry | go to EDA H-mode part of the MP request: NL_04=0.85e20, RF power stepped from 1.5 to 2.0 MW at 1. sec actual: NL_04=1.1e20, RF tripped, no H-modes timings are still all set around 0.8 s |
| Jun 13 2003 04:56:39:860PM | 1030613035 | Jim Terry | try to repeat with RF staying on request: NL_04=0.85e20, RF power stepped from 1.5 to 2.0 MW at 1. sec actual: NL_04=1.1e20, RF tripping, no H-modes timings are still all set around 0.8 s |
| Jun 13 2003 04:58:15:503PM | 1030613036 | Jim Terry | try to repeat with RF staying on fizzle |
| Physics Operator Comments | |||
| Jun 13 2003 08:58:17:297AM | Dmitri Mossessian | Comntinue yesterday's runa (MP282). For details see SESSION LEADER logbook entries for yesterday. Load 1030612006. RF from .7 s, 4 MW - attempt to repeat shots 6 taht had large ELMs driven by current | |
| Jun 13 2003 09:06:50:760AM | 1030613001 | Dmitri Mossessian | No power shot - Josh is working on some software Next shot - try plasma |
| Jun 13 2003 09:36:23:310AM | 1030613002 | Dmitri Mossessian | Good H-mode. Only 1.3 MW of RF. No current ramp effect. Next shot - try full RF power. Drop upper triangularity (RXU out 1 cm) and elongation (ZXU up 1 cm) |
| Jun 13 2003 09:57:35:070AM | 1030613004 | Dmitri Mossessian | RF not steady. Plasma disrupted after current ramp due to large injection (caused by RF ?) Next shot - move beginning of RF to 0.9 s to get hotter H-mode into current ramp. Reduce upper delta some more (RXU + 1cm). Add 2 mm ramp to RCUR at .95 s to try to compensate for current ramp effect |
| Jun 13 2003 10:09:45:630AM | 1030613005 | Dmitri Mossessian | RF trips a lot. Next shot - plasma seems to be stable enough and we will try to increase current ramp rate somewhat. RXU + 1cm Add 3 mm to RCUR to increase right gap a little |
| Jun 13 2003 10:18:49:497AM | 1030613006 | Dmitri Mossessian | Good shot. Steady RF at 3.5 MW, Te_ped ~ 500 eV, good current rise. definitely no ELMs driven Next shot - lower target density to 5e19 |
| Jun 13 2003 10:29:59:400AM | 1030613007 | Dmitri Mossessian | Good shot. Target 6e19. Te_ped ~ 500 eV. Burst of ELMs between 1 and 1.04 s. Next shot - turn current ramp OFF |
| Jun 13 2003 10:51:42:830AM | 1030613008 | Dmitri Mossessian | Good shot. Repeats shot 7 but grassy ELMs disappear. Try to increase the effect on next couple of shots - increase RF power and drop upper delta more. Next shot - RXU + 1cm, current ramp on. Increase current ramp rate - now ramping to .85 MA |
| Jun 13 2003 10:58:38:853AM | 1030613009 | Dmitri Mossessian | Decreasing upper delta seems to make things worse - almost no effect of current ramp seen on D-alpha. Next shot - RXU -2 cm |
| Jun 13 2003 11:16:13:750AM | 1030613010 | Dmitri Mossessian | Lost density feedback in the middle of the shot. Got max gas puff right from the beginning of H-mode. After H-L transition density was rising and plasma disrupted at 1.46 s Next shot - repeat with higher current ramp rate. PG4 from 23 to 21 ms |
| Jun 13 2003 11:26:11:697AM | 1030613011 | Dmitri Mossessian | Better than 10 although still disrupted. ELMs seem to be there during Ip ramp. This ends MP 282 Next shot - go to MP 332. Load segment 2 from 1030604010. |
| Jun 13 2003 11:44:37:780AM | 1030613012 | Dmitri Mossessian | Plasma. nl=0.8e20, asked for 0.7e20. Next shot - CLEARIN down 5 mm |
| Jun 13 2003 11:59:29:487AM | 1030613013 | Dmitri Mossessian | Plasma. After F-probe plunge at 0.8 s edge cools down to 0 eV at 0.85 for 150 ms. Next shot - add 10 ms to Ar (PG1). CLEARIN down 3 mm |
| Jun 13 2003 12:06:37:540PM | 1030613014 | Dmitri Mossessian | Plasma Next shot - nl -> 5e19 |
| Jun 13 2003 12:32:43:570PM | 1030613015 | Dmitri Mossessian | Plasma Next shot - no changes |
| Jun 13 2003 12:32:33:697PM | 1030613016 | Dmitri Mossessian | Plasma Next shot - nl -> 4e19 |
| Jun 13 2003 12:48:20:557PM | 1030613017 | Dmitri Mossessian | Plasma Next shot - CLEARIN + 2mm |
| Jun 13 2003 01:00:42:417PM | 1030613018 | Dmitri Mossessian | Plasma. Disrupted at .3 s - lost TCI feedback Next shot - no changes |
| Jun 13 2003 01:12:55:163PM | 1030613019 | Dmitri Mossessian | Plasma. Next shot - nl-> 3e19 |
| Jun 13 2003 01:45:10:110PM | 1030613021 | Dmitri Mossessian | Plasma. Next shot - nl -> 5e19 Ip -> 0.8 MA |
| Jun 13 2003 01:59:28:687PM | 1030613022 | Dmitri Mossessian | Plasma. Next shot - nl -> 1e20 Ip -> 0.6 MA |
| Jun 13 2003 02:05:20:553PM | 1030613023 | Dmitri Mossessian | No power shot. EF troubles |
| Jun 13 2003 02:29:02:190PM | 1030613024 | Dmitri Mossessian | Plasma killed by giant MARFE that starts around 0.5 s. Next shot - slow down density rise to bring it to 1e20 by 0.8 s |
| Jun 13 2003 02:39:49:453PM | 1030613025 | Dmitri Mossessian | Good shot Next shot - no change |
| Jun 13 2003 03:08:12:860PM | 1030613026 | Dmitri Mossessian | Good shot Next shot - nl -> 1.1e20 |
| Jun 13 2003 03:08:22:220PM | 1030613027 | Dmitri Mossessian | Good shot Next shot - no change |
| Jun 13 2003 03:13:22:473PM | 1030613028 | Dmitri Mossessian | Good shot Next shot - nl -> 1.2e20 |
| Jun 13 2003 03:28:32:740PM | 1030613029 | Dmitri Mossessian | Good shot Next shot - no change |
| Jun 13 2003 03:48:51:877PM | 1030613030 | Dmitri Mossessian | Fizzle. Current rise too fast Next shot - add 3 ms to PG4 21 -> 24 ms |
| Jun 13 2003 03:55:14:147PM | 1030613031 | Dmitri Mossessian | Plasma. Next shot - nl-> 0.85e20, add 2 ms to PG4 |
| Jun 13 2003 04:11:50:090PM | 1030613032 | Dmitri Mossessian | Fizzle. Too much gas Next shot - reduce PG4 (-3 ms) |
| Jun 13 2003 04:21:52:100PM | 1030613033 | Dmitri Mossessian | Plasma. Very bad startup Next shot - nl -> 1e20 |
| Jun 13 2003 04:32:01:363PM | 1030613034 | Dmitri Mossessian | Plasma. Startup is good. No H-mode - poor RF matching Next shot -repeat |
| Jun 13 2003 04:59:09:970PM | 1030613036 | Dmitri Mossessian | Fizzle |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:01:11:080AM | Test | Ok | datasystem test |
| 2 | 09:15:40:050AM | Plasma | Ok | |
| 3 | 09:29:20:287AM | Plasma | Ok | |
| 4 | 09:43:05:537AM | Plasma | Ok | |
| 5 | 09:56:43:567AM | Plasma | Ok | |
| 6 | 10:10:46:973AM | Plasma | Ok | |
| 7 | 10:23:38:250AM | Plasma | Ok | |
| 8 | 10:36:37:017AM | Plasma | Ok | |
| 9 | 10:52:38:003AM | Plasma | Ok | |
| 10 | 11:05:33:487AM | Plasma | Ok | |
| 11 | 11:19:28:033AM | Plasma | Ok | |
| 12 | 11:32:15:643AM | Plasma | Ok | |
| 13 | 11:45:29:830AM | Plasma | Ok | |
| 14 | 12:00:03:423PM | Plasma | Ok | |
| 15 | 12:15:14:317PM | Plasma | Ok | |
| 16 | 12:28:39:770PM | Plasma | Ok | |
| 17 | 12:41:39:957PM | Plasma | Ok | |
| 18 | 12:54:22:207PM | Plasma | Ok | |
| 19 | 01:07:49:410PM | Plasma | Ok | |
| 20 | 01:20:59:157PM | Plasma | Ok | |
| 21 | 01:34:15:970PM | Plasma | Ok | |
| 22 | 01:48:12:893PM | Plasma | Ok | |
| 23 | 02:01:57:923PM | Plasma | Bad | EF1L did not charge |
| 24 | 02:16:57:643PM | Plasma | Ok | |
| 25 | 02:30:59:973PM | Plasma | Ok | |
| 26 | 02:44:18:207PM | Plasma | Ok | |
| 27 | 02:57:35:880PM | Plasma | Ok | |
| 28 | 03:11:16:253PM | Plasma | Ok | |
| 29 | 03:24:54:910PM | Plasma | Ok | |
| 30 | 03:37:39:877PM | Plasma | Ok | |
| 31 | 03:50:51:877PM | Plasma | Ok | |
| 32 | 04:03:33:703PM | Plasma | Ok | |
| 33 | 04:16:10:690PM | Plasma | Ok | |
| 34 | 04:29:05:000PM | Plasma | Ok | |
| 35 | 04:41:50:950PM | Plasma | Ok | |
| 36 | 04:55:04:703PM | Plasma | Ok | |