| Session leader(s): | Bruce Lipschultz |
| Physics operator(s): | Jim Irby |
| Engineering operator(s): | Ed Fitzgerald,Bill Parkin,Gary Dekow |
| Engineering Operator Run Comment |
| Boronization Recovery PO: Irby; EO: Dekow/Fitz/Parkin |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:34:820PM |
| Author: Bruce Lipschultz |
| Conditioning and cleanup with piggyback of MP 364 - 'Measurement of wall pumping on Alcator C-Mod' This mini-proposal has a number of interconnected goals all having to do with the wall sources and sinks of neutrals. First we would like to determine the role of the wall/limiters as a source of neutrals during RF power injection. The role of boronization in affecting the wall pumping/sources will be addressed. Understanding the processes involved will help us better control the plasma density (better understand the utility of the cryopump) and perhaps the H/D ratio. A further goal is to understand the scaling of pumping processes to enable prediction of the T stored in a high-Z first-wall in a BPX w/B in the vessel. Summary of results: Between 1031106 and 1031107 the machine was boronized. On 1031107 we were back in piggyback mode on top of boronization recovery and conditioning. H/D was significantly lower (3-4%) and the walls were outgassing through almost the entire day (unusual). So we would have to say that boronization certainly loads up the walls with gas. And that gas is D which, when it comes out, lowers H/D. We also looked at all shots for a given day and integrated all gas in and gas out over the shots where it was measured. On 1031104 there was a surfeit of 9% of the gas puffed (26 torr-liters) of gas out over in. This changed to 9% of the 528 torr-liters puffed (49 torr-liters) being pumped on 1031106, the day with the most shots measured. Finally, on 1031107 (after boronization) there again was a surplus of gas out over in of 13% (17 torr-liters). |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:19:660PM |
| Author: Jim Irby |
| Run 1031107: Boronization Recovery Engineering setup for Friday, 07 Nov 2003 Purpose: Recovery from Boronization EO: Dekow, Fitzgerald, Parkin Physics operator: Irby The machine was boronized overnight with 140 psi of B2D6 resulting in an average deposition thickness of 2048A. Following boronization, approximately 90 minutes of ECDC in D2 was done. Run begins at 09:00 and ends at 17:00. Power systems the same as on 1031106008 (0.8 MA, 5.4 T, lower single null) A-coils should be hooked up as on 1030507012 (+Dtop -Dbot -Jtop +Jbot), but the power supply should NOT be enabled. Gas setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid enabled (PG1) leave B-side upper as is Hybrid DISABLED (PG2) fill C-side with 30 psi D2 Hybrid enabled (PG3) Enable the following gate valves: ECE, VUV, DNB --------------------------------------------------------------------- RF Setup: All 4 transmitters in Run On by 08:00. --------------------------------------------------------------------- Run Plan: Start with lower null plasmas and bring up machine and rf as possible. --------------------------------------------------------------------- Summary: We had many duds and fizzles today. I'm sure operation will be much better next week after a few days of ecdc. We devoted the first 5 shots to fixing a problem with the data system. It turned out to be a bad power supply in the bus HV camac crate. We got our first plasma on shot 7, with about 1.5 MW of rf, and a nice h-mode. Then we had a series of fizzles and duds until shot 14 which was another good plasma. The h/(h+d) was down to 3 or 4% for these shots and the carbon II light was down a factor of 3 or 4 indicating that the boronization did its job. The difficulty with recovery also indicated that we had covered surfaces well. Shot 16 was a good shot with the h-mode beginning very soon after application of rf (as opposed to 7 and 14 with a 200 ms delay). RF struggled to get going again after boronization. Unfortunately there were only a few plasmas for them to get going on. The prefill gas pressure varied wildly from shot to shot. So I spent a great deal of effort trimming the gas puff pulse width. It seemed that a +-5% change in prefill pressure could take you from dud to fizzle. We should think of a better way to control the gas. The ratiomatic gauge also misbehaved on several shots, making it particularly hard to figure out what was going on. Steve Wolfe noted a problem with the EF1L power supply similar to the problem we had in 1999. Since we had the problem all day yesterday, it probably is not affecting startup, but we should look at the problem on Monday. Things to fix on Monday: EF1L G-Side Ratiomatic RF may want to vacuum condition on Monday Score: Duds 11,12,13,16,18,23,24,28,32,33,34 Fizzles 06,08,09,10,15,21,26,27,30,31 Plasmas 07,14,17,19,20,22,25,29 Tests 01,02,03,04,05 |
| Session Leader Comments |
| Physics Operator Comments | |||
| Nov 7 2003 07:59:16:737AM | Jim Irby | Engineering setup for Friday, 07 Nov 2003 Purpose: Recovery from Boronization EO: Physics operator: Irby The machine was boronized overnight with 140 psi of B2D6 resulting in an average deposition thickness of 2048A. Following boronization, approximately 90 minutes of ECDC in D2 was done. Run begins at 09:00 and ends at 17:00. Power systems the same as on 1031106008 (0.8 MA, 5.4 T, Lower single null) A-coils should be hooked up as on 1030507012 (+Dtop -Dbot -Jtop +Jbot), but the power supply should NOT be enabled. Gas setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid enabled (PG1) leave B-side upper as is Hybrid DISABLED (PG2) fill C-side with 30 psi D2 Hybrid enabled (PG3) Enable the following gate valves: ECE, VUV, DNB ------------------------------------------------------------------------------- RF Setup: All 4 transmitters in Run On by 08:00. ------------------------------------------------------------------------------- Run Plan: Start with lower null plasmas and bring up machine and rf as possible. | |
| Nov 7 2003 08:40:16:813AM | Jim Irby | Loaded seg 2 with seg 2 from 1031106008 Initial EF4 setting from yesterday -1330. Dropped density request to 0.8e20 / m^2 | |
| Nov 7 2003 08:59:30:533AM | 1031107001 | Jim Irby | Cycle test to check gas and data system Note that gas was 0.04 mTorr vs 0.06 on the last shot from yesterday Had lots of data system errors: no magnetics, no power room data PO jumped the gun and started test shot before PCS was fully loaded. Reloaded PCS and then did Hybrid coldstart to get everything in sync again. |
| Nov 7 2003 09:08:10:277AM | 1031107002 | Jim Irby | Second test shot to make sure data system is back online Still have data system troubles! Gas puff still low (.04) |
| Nov 7 2003 09:37:25:020AM | 1031107003 | Jim Irby | Another cycle test --- cycled highway driver Somewhat better, but still having missing data. Will try taking some crates out of the loop for the next test. |
| Nov 7 2003 09:52:38:570AM | 1031107004 | Jim Irby | Data system looks much better, but still a missing signal or two gas puff has not changed during the four cycle tests --- will raise it for the first plasma attempt. |
| Nov 7 2003 10:09:47:370AM | 1031107005 | Jim Irby | changed bus HV camac crate power supply pre puff increased from 22 to 25 ms. data system is now operational --- next shot try for plasma little more gas, but will increase a little more for next shot. |
| Nov 7 2003 10:24:09:983AM | 1031107006 | Jim Irby | pre puff from 25 to 27 ms Try for plasma --- fizzle --- prepuff a little high --- CII much lower than yesterday |
| Nov 7 2003 10:47:52:060AM | 1031107007 | Jim Irby | pre puff back to 25 ms ef4 from -1330 to -1300. basepressure before shot 4.1e-7 Torr plasma into rampdown --- nice h-mode with 1.5 MW of rf takes 200 ms to get into h-mode about 70 kJ of stored energy BIII signal is actually lower than on shot 08 from yesterday! CII signal factor of 2 to 4 down H/(H+D) 3 to 4 % |
| Nov 7 2003 10:53:14:163AM | 1031107008 | Jim Irby | EF4 from -1300 to -1310 --- Bz0 a little high compared to yesterday, and may go higher still next this shot fizzle --- fields and gas looked okay |
| Nov 7 2003 11:06:01:733AM | 1031107009 | Jim Irby | fizzle |
| Nov 7 2003 11:23:15:737AM | 1031107010 | Jim Irby | EF4 to -1320 pre puff to 23 ms from 25 ms fizzle --- play with EF4 again next shot |
| Nov 7 2003 11:37:55:990AM | 1031107011 | Jim Irby | Bz0 looks high compared to shot 8 from yesterday, also last shot EF4 back to -1330 --- yesterday's setting Dud ---- |
| Nov 7 2003 11:53:15:667AM | 1031107012 | Jim Irby | EF4 to -1300 --- back to what we had on shot 007 dud! |
| Nov 7 2003 12:16:03:257PM | 1031107013 | Jim Irby | try to match yesterday's shot 29 a little better: ef4 to -1310 pre puff from 23 to 24 ms data system problem --- no power shot |
| Nov 7 2003 12:34:50:760PM | 1031107014 | Jim Irby | plasma into rampdown --- rf power about 1.5 MW --- h-mode after 200 ms |
| Nov 7 2003 12:35:42:367PM | 1031107015 | Jim Irby | no pcs changes fizzle --- didn't drop prepuff --- pressure high compared to 14 |
| Nov 7 2003 12:56:52:587PM | 1031107016 | Jim Irby | gas puff to 22 ms from 24. dud --- gas still higher than on 14 |
| Nov 7 2003 01:11:29:357PM | 1031107017 | Jim Irby | gas to 21 ms from 22 ms plasma into rampdown --- current rise a little faster than on 14, pressure a little lower tci feedback hene counter driven to limit --- feedback signal too low early in shot h-mode started earlier than on 14, but lost most of rf and h-mode after 1.1 s 76 kJ |
| Nov 7 2003 01:19:21:943PM | 1031107018 | Jim Irby | no pcs changes dud --- gas too high again, should have dropped it a little before shot |
| Nov 7 2003 01:40:47:223PM | 1031107019 | Jim Irby | pre puff from 21 to 20 ms plasma into rampdown --- clean startup rf power down a little --- h-mode a little later than on 17 |
| Nov 7 2003 01:52:35:260PM | 1031107020 | Jim Irby | no pcs changes plasma into rampdown ---- short h-mode, lots of rf interupts gas and fields very similar to 19 |
| Nov 7 2003 01:58:00:710PM | 1031107021 | Jim Irby | no pcs changes fizzle --- pressure is up again! |
| Nov 7 2003 02:25:35:783PM | 1031107022 | Jim Irby | pre puff from 20 to 19 ms. plasma --- clean but short h-mode period starting at .77 s |
| Nov 7 2003 02:39:23:460PM | 1031107023 | Jim Irby | no pcs changes dud --- gas now too low --- this is fun |
| Nov 7 2003 02:46:44:250PM | 1031107024 | Jim Irby | gas from 20 to 21 ms dud --- gas still low! |
| Nov 7 2003 03:11:30:887PM | 1031107025 | Jim Irby | pre puff from 21 to 23 ms plasma into rampdown --- gas and current startup identical to shot 17 |
| Nov 7 2003 03:12:56:963PM | 1031107026 | Jim Irby | fizzle --- gas now too high |
| Nov 7 2003 03:23:49:107PM | 1031107027 | Jim Irby | gas back to 21 ms fizzle --- gas very low |
| Nov 7 2003 03:35:39:810PM | 1031107028 | Jim Irby | pre puff to 22 ms dud --- gas a little low now but... |
| Nov 7 2003 03:59:08:747PM | 1031107029 | Jim Irby | pre puff back to 23 ms plasma --- short h-mode starting late prefill pressure an overlay of shot 17 h/(h+d) still 3 to 5% |
| Nov 7 2003 04:13:08:857PM | 1031107030 | Jim Irby | no pcs changes --- will probably regret it fizzle --- pressue down a factor of two! Gauge problem.... |
| Nov 7 2003 04:19:32:903PM | 1031107031 | Jim Irby | no pcs changes fizzle --- gas 10% high again asked rf to turn off j-port since it seems to need vacuum conditioning anyway. |
| Nov 7 2003 04:32:15:370PM | 1031107032 | Jim Irby | pre puff to 21 ms DNB given up for the day --- gatevalve will be closed rest of run dud --- gauge out to lunch again |
| Nov 7 2003 04:42:39:387PM | 1031107033 | Jim Irby | import seg 1 from shot 1031107017 to seg 1 Steve Wolfe has noted a problem with the EF1L power supply --- probably not affecting our startup since we had the problem all day yesterday. dud --- no gauge |
| Nov 7 2003 04:54:22:760PM | 1031107034 | Jim Irby | prefill to 23 ms one last time --- this is the last try dud --- done |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:40:37:063AM | Test | Ok | |
| 2 | 09:03:46:000AM | Test | Bad | camac problems |
| 3 | 09:28:36:840AM | Test | Bad | Nox error on camac |
| 4 | 09:39:34:753AM | Test | Ok | |
| 5 | 10:01:08:580AM | Test | Ok | |
| 6 | 10:10:54:587AM | Plasma | Ok | |
| 7 | 10:31:33:010AM | Plasma | Ok | |
| 8 | 10:46:45:920AM | Plasma | Ok | |
| 9 | 10:59:33:943AM | Plasma | Ok | |
| 10 | 11:12:15:070AM | Plasma | Ok | |
| 11 | 11:24:44:720AM | Plasma | Ok | |
| 12 | 11:39:28:333AM | Plasma | Ok | |
| 13 | 11:55:00:150AM | Test | Bad | Data System Hung |
| 14 | 12:17:27:083PM | Plasma | Ok | |
| 15 | 12:31:02:950PM | Plasma | Ok | |
| 16 | 12:43:35:377PM | Plasma | Ok | |
| 17 | 12:59:03:350PM | Plasma | Ok | |
| 18 | 01:12:15:667PM | Plasma | Ok | |
| 19 | 01:24:54:987PM | Plasma | Ok | |
| 20 | 01:37:21:900PM | Plasma | Ok | |
| 21 | 01:52:54:917PM | Plasma | Ok | |
| 22 | 02:09:51:967PM | Plasma | Ok | |
| 23 | 02:28:09:077PM | Plasma | Ok | |
| 24 | 02:40:36:397PM | Plasma | Ok | |
| 25 | 02:53:42:060PM | Plasma | Ok | |
| 26 | 03:06:36:440PM | Plasma | Ok | |
| 27 | 03:19:32:357PM | Plasma | Ok | |
| 28 | 03:32:18:917PM | Plasma | Ok | |
| 29 | 03:44:51:510PM | Plasma | Ok | |
| 30 | 03:59:40:310PM | Plasma | Ok | |
| 31 | 04:12:50:213PM | Plasma | Ok | |
| 32 | 04:25:18:480PM | Plasma | Ok | |
| 33 | 04:38:00:323PM | Plasma | Ok | |
| 34 | 04:52:02:417PM | Plasma | Ok | |