Alcator C-Mod Run 1031107 Information

Back to runs

Miniproposals
Miniproposal:364
Date Filed:11/14/2003
Title:Measurement of wall pumping on Alcator C-Mod
First Author:Bruce Lipschultz
Session Leader:Bruce Lipschultz (shots 1-34)

Operators
Session leader(s):Bruce Lipschultz
Physics operator(s):Jim Irby
Engineering operator(s):Ed Fitzgerald,Bill Parkin,Gary Dekow

Engineering Operator Run Comment
Boronization Recovery PO: Irby; EO: Dekow/Fitz/Parkin

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:34:820PM
Author: Bruce Lipschultz
Conditioning and cleanup with piggyback of MP 364 - 'Measurement of
wall pumping on Alcator C-Mod'

This mini-proposal has a number of interconnected goals all having
to do with the wall sources and sinks of neutrals. First we would
like to determine the role of the wall/limiters as a source of
neutrals during RF power injection. The role of boronization in
affecting the wall pumping/sources will be addressed. Understanding
the processes involved will help us better control the plasma
density (better understand the utility of the cryopump) and perhaps
the H/D ratio. A further goal is to understand the scaling of
pumping processes to enable prediction of the T stored in a
high-Z first-wall in a BPX w/B in the vessel.

Summary of results:
Between 1031106 and 1031107 the machine was boronized.
On 1031107 we were back in piggyback mode on top of
boronization recovery and conditioning. H/D was significantly
lower (3-4%) and the walls were outgassing through almost the
entire day (unusual). So we would have to say that boronization
certainly loads up the walls with gas. And that gas is D which,
when it comes out, lowers H/D.
We also looked at all shots for a given day and integrated
all gas in and gas out over the shots where it was measured. On
1031104 there was a surfeit of 9% of the gas puffed (26 torr-liters)
of gas out over in. This changed to 9% of the 528 torr-liters
puffed (49 torr-liters) being pumped on 1031106, the day with the
most shots measured. Finally, on 1031107 (after boronization) there
again was a surplus of gas out over in of 13% (17 torr-liters).

Physics Operator Summaries
Entered: Jul 7 2004 04:37:19:660PM
Author: Jim Irby
Run 1031107: Boronization Recovery

Engineering setup for Friday, 07 Nov 2003

Purpose: Recovery from Boronization

EO: Dekow, Fitzgerald, Parkin
Physics operator: Irby

The machine was boronized overnight with 140 psi of B2D6 resulting in
an average deposition thickness of 2048A. Following boronization,
approximately 90 minutes of ECDC in D2 was done.

Run begins at 09:00 and ends at 17:00.

Power systems the same as on 1031106008 (0.8 MA, 5.4 T, lower single null)

A-coils should be hooked up as on 1030507012 (+Dtop -Dbot -Jtop
+Jbot), but the power supply should NOT be enabled.

Gas setup:

fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves: ECE, VUV, DNB

---------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 08:00.
---------------------------------------------------------------------

Run Plan:

Start with lower null plasmas and bring up machine and rf as possible.


---------------------------------------------------------------------
Summary:


We had many duds and fizzles today. I'm sure operation will be much
better next week after a few days of ecdc.

We devoted the first 5 shots to fixing a problem with the data system.
It turned out to be a bad power supply in the bus HV camac crate.

We got our first plasma on shot 7, with about 1.5 MW of rf, and a nice
h-mode. Then we had a series of fizzles and duds until shot 14 which
was another good plasma. The h/(h+d) was down to 3 or 4% for these
shots and the carbon II light was down a factor of 3 or 4 indicating
that the boronization did its job. The difficulty with recovery also
indicated that we had covered surfaces well. Shot 16 was a good shot
with the h-mode beginning very soon after application of rf (as
opposed to 7 and 14 with a 200 ms delay).

RF struggled to get going again after boronization. Unfortunately
there were only a few plasmas for them to get going on.

The prefill gas pressure varied wildly from shot to shot. So I spent
a great deal of effort trimming the gas puff pulse width. It seemed
that a +-5% change in prefill pressure could take you from dud to
fizzle. We should think of a better way to control the gas. The
ratiomatic gauge also misbehaved on several shots, making it
particularly hard to figure out what was going on.

Steve Wolfe noted a problem with the EF1L power supply similar to the
problem we had in 1999. Since we had the problem all day yesterday,
it probably is not affecting startup, but we should look at the
problem on Monday.

Things to fix on Monday:

EF1L

G-Side Ratiomatic

RF may want to vacuum condition on Monday

Score:

Duds 11,12,13,16,18,23,24,28,32,33,34
Fizzles 06,08,09,10,15,21,26,27,30,31
Plasmas 07,14,17,19,20,22,25,29
Tests 01,02,03,04,05

Session Leader Comments

Physics Operator Comments
Nov 7 2003 07:59:16:737AMJim IrbyEngineering setup for Friday, 07 Nov 2003

Purpose: Recovery from Boronization

EO:
Physics operator: Irby

The machine was boronized overnight with 140 psi of B2D6 resulting in an average deposition thickness
of 2048A. Following boronization, approximately 90 minutes of ECDC in D2 was done.

Run begins at 09:00 and ends at 17:00.

Power systems the same as on 1031106008 (0.8 MA, 5.4 T, Lower single null)

A-coils should be hooked up as on 1030507012 (+Dtop -Dbot -Jtop +Jbot), but the power supply should
NOT be enabled.

Gas setup:

fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves: ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 08:00.

-------------------------------------------------------------------------------
Run Plan: Start with lower null plasmas and bring up machine and rf as
possible.
Nov 7 2003 08:40:16:813AMJim IrbyLoaded seg 2 with seg 2 from 1031106008

Initial EF4 setting from yesterday -1330.

Dropped density request to 0.8e20 / m^2

Nov 7 2003 08:59:30:533AM1031107001Jim IrbyCycle test to check gas and data system

Note that gas was 0.04 mTorr vs 0.06 on the last shot from yesterday

Had lots of data system errors: no magnetics, no power room data



PO jumped the gun and started test shot before PCS was fully loaded.
Reloaded PCS and then did Hybrid coldstart to get everything in sync again.



Nov 7 2003 09:08:10:277AM1031107002Jim IrbySecond test shot to make sure data system is back online

Still have data system troubles!

Gas puff still low (.04)

Nov 7 2003 09:37:25:020AM1031107003Jim IrbyAnother cycle test --- cycled highway driver

Somewhat better, but still having missing data.

Will try taking some crates out of the loop for the next
test.
Nov 7 2003 09:52:38:570AM1031107004Jim IrbyData system looks much better, but still a missing signal or two

gas puff has not changed during the four cycle tests --- will raise it for the first
plasma attempt.
Nov 7 2003 10:09:47:370AM1031107005Jim Irbychanged bus HV camac crate power supply

pre puff increased from 22 to 25 ms.

data system is now operational --- next shot try for plasma

little more gas, but will increase a little more
for next shot.
Nov 7 2003 10:24:09:983AM1031107006Jim Irbypre puff from 25 to 27 ms

Try for plasma ---

fizzle --- prepuff a little high --- CII much lower than yesterday


Nov 7 2003 10:47:52:060AM1031107007Jim Irbypre puff back to 25 ms

ef4 from -1330 to -1300.

basepressure before shot 4.1e-7 Torr

plasma into rampdown --- nice h-mode with 1.5 MW of rf

takes 200 ms to get into h-mode

about 70 kJ of stored energy

BIII signal is actually lower than on shot 08 from yesterday!

CII signal factor of 2 to 4 down

H/(H+D) 3 to 4 %
Nov 7 2003 10:53:14:163AM1031107008Jim IrbyEF4 from -1300 to -1310 --- Bz0 a little high compared to yesterday, and may go higher still next
this shot

fizzle --- fields and gas looked okay
Nov 7 2003 11:06:01:733AM1031107009Jim Irbyfizzle
Nov 7 2003 11:23:15:737AM1031107010Jim IrbyEF4 to -1320
pre puff to 23 ms from 25 ms

fizzle --- play with EF4 again next shot

Nov 7 2003 11:37:55:990AM1031107011Jim IrbyBz0 looks high compared to shot 8 from yesterday, also last shot
EF4 back to -1330 --- yesterday's setting

Dud ----
Nov 7 2003 11:53:15:667AM1031107012Jim IrbyEF4 to -1300 --- back to what we had on shot 007

dud!

Nov 7 2003 12:16:03:257PM1031107013Jim Irbytry to match yesterday's shot 29 a little better:
ef4 to -1310
pre puff from 23 to 24 ms

data system problem --- no power shot
Nov 7 2003 12:34:50:760PM1031107014Jim Irbyplasma into rampdown --- rf power about 1.5 MW --- h-mode after 200 ms

Nov 7 2003 12:35:42:367PM1031107015Jim Irbyno pcs changes

fizzle --- didn't drop prepuff --- pressure high compared to 14

Nov 7 2003 12:56:52:587PM1031107016Jim Irbygas puff to 22 ms from 24.

dud --- gas still higher than on 14

Nov 7 2003 01:11:29:357PM1031107017Jim Irbygas to 21 ms from 22 ms

plasma into rampdown --- current rise a little faster than on 14, pressure a little lower

tci feedback hene counter driven to limit --- feedback signal too low early in shot

h-mode started earlier than on 14, but lost most of rf and h-mode after 1.1 s

76 kJ
Nov 7 2003 01:19:21:943PM1031107018Jim Irbyno pcs changes

dud --- gas too high again, should have dropped it a little before shot

Nov 7 2003 01:40:47:223PM1031107019Jim Irbypre puff from 21 to 20 ms

plasma into rampdown --- clean startup

rf power down a little --- h-mode a little later than on 17

Nov 7 2003 01:52:35:260PM1031107020Jim Irbyno pcs changes

plasma into rampdown ---- short h-mode, lots of rf interupts

gas and fields very similar to 19


Nov 7 2003 01:58:00:710PM1031107021Jim Irbyno pcs changes

fizzle --- pressure is up again!

Nov 7 2003 02:25:35:783PM1031107022Jim Irbypre puff from 20 to 19 ms.

plasma --- clean but short h-mode period starting at .77 s

Nov 7 2003 02:39:23:460PM1031107023Jim Irbyno pcs changes

dud --- gas now too low --- this is fun

Nov 7 2003 02:46:44:250PM1031107024Jim Irbygas from 20 to 21 ms

dud --- gas still low!


Nov 7 2003 03:11:30:887PM1031107025Jim Irbypre puff from 21 to 23 ms

plasma into rampdown --- gas and current startup identical to shot 17

Nov 7 2003 03:12:56:963PM1031107026Jim Irbyfizzle --- gas now too high

Nov 7 2003 03:23:49:107PM1031107027Jim Irbygas back to 21 ms

fizzle --- gas very low


Nov 7 2003 03:35:39:810PM1031107028Jim Irbypre puff to 22 ms

dud --- gas a little low now but...

Nov 7 2003 03:59:08:747PM1031107029Jim Irbypre puff back to 23 ms

plasma --- short h-mode starting late

prefill pressure an overlay of shot 17

h/(h+d) still 3 to 5%
Nov 7 2003 04:13:08:857PM1031107030Jim Irbyno pcs changes --- will probably regret it

fizzle --- pressue down a factor of two! Gauge problem....



Nov 7 2003 04:19:32:903PM1031107031Jim Irbyno pcs changes

fizzle --- gas 10% high again

asked rf to turn off j-port since it seems to need vacuum conditioning anyway.


Nov 7 2003 04:32:15:370PM1031107032Jim Irbypre puff to 21 ms

DNB given up for the day --- gatevalve will be closed rest of run

dud --- gauge out to lunch again


Nov 7 2003 04:42:39:387PM1031107033Jim Irbyimport seg 1 from shot 1031107017 to seg 1

Steve Wolfe has noted a problem with the EF1L power supply --- probably not affecting our startup since
we had the problem all day yesterday.

dud --- no gauge
Nov 7 2003 04:54:22:760PM1031107034Jim Irbyprefill to 23 ms one last time --- this is the last try

dud --- done

Engineering Operator Comments
ShotTimeTypeStatusComment
108:40:37:063AMTestOk
209:03:46:000AMTestBadcamac problems
309:28:36:840AMTestBadNox error on camac
409:39:34:753AMTestOk
510:01:08:580AMTestOk
610:10:54:587AMPlasmaOk
710:31:33:010AMPlasmaOk
810:46:45:920AMPlasmaOk
910:59:33:943AMPlasmaOk
1011:12:15:070AMPlasmaOk
1111:24:44:720AMPlasmaOk
1211:39:28:333AMPlasmaOk
1311:55:00:150AMTestBadData System Hung
1412:17:27:083PMPlasmaOk
1512:31:02:950PMPlasmaOk
1612:43:35:377PMPlasmaOk
1712:59:03:350PMPlasmaOk
1801:12:15:667PMPlasmaOk
1901:24:54:987PMPlasmaOk
2001:37:21:900PMPlasmaOk
2101:52:54:917PMPlasmaOk
2202:09:51:967PMPlasmaOk
2302:28:09:077PMPlasmaOk
2402:40:36:397PMPlasmaOk
2502:53:42:060PMPlasmaOk
2603:06:36:440PMPlasmaOk
2703:19:32:357PMPlasmaOk
2803:32:18:917PMPlasmaOk
2903:44:51:510PMPlasmaOk
3003:59:40:310PMPlasmaOk
3104:12:50:213PMPlasmaOk
3204:25:18:480PMPlasmaOk
3304:38:00:323PMPlasmaOk
3404:52:02:417PMPlasmaOk