Alcator C-Mod Run 1031205 Information

Back to runs

Miniproposals
Miniproposal:355
Date Filed:11/12/2003
Title:ICRF Testing & Conditioning
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-22)

Operators
Session leader(s):Steve Wukitch
Physics operator(s):Ron Parker
Engineering operator(s):Bill Parkin,Bill Byford,Gary Dekow

Engineering Operator Run Comment
Boronization Recovery SL: Wukitch; PO: Parker; EO:Dekow/Byford/Parkin

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:35:040PM
Author: Steve Wukitch
Engineering setup for Fri. 5 Dec 2003

MP#355 --- ICRF Conditioning

Session leader : Wukitch
Physics operator: Parker

Boronization overnight
ECDC for 30 minutes post antenna vacuum conditioning in D2 at 2e-4 Torr
Bake at 60 C overnight as well.

Run begins at 09:00 and ends at 17:00.

Power systems the same as on 1031204037.

A-coils should be hooked up as on 1031204037 and the power supply should be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable gatevalves (there will be no vacuum problems): ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 08:00
-------------------------------------------------------------------------------

Session Leader Run Plan:

Recondition RF antennas to power. Fiducial discharges (103120437)
will be the target plasma: BT~5.4 T, Ip~1 MA, nl_04~0.8, right gap of
1 cm.

-------------------------------------------------------------------------------

Yijun vacuum conditioned this morning post boronization
Conditioning went extremely well and faster than previous boronization
-------------------------------------------------------------------------------
001-4,8,10,12,20,22 NTP
005 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 0.25, .5, .75, 1.0 MW in steps [0.6,1.5] sec
E: 0.25, .5, .75, 1.0 MW in steps
J: 0.5, 1.0, 1.5, 2.0 MW in steps
result: plasma, H-mode, nl_04~1
D: ran faults in 1 MW step
E: ran 2 faults late
J: ran max faults
006 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.0 MW [0.6,1.5] sec
E: 1.0 MW
J: 2.0 MW
result: plasma, H-mode, nl_04~0.9
D: ran 2 faults late
E: ran 2 faults late
J: ran max faults
007 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.1 MW [0.6,1.5] sec
E: 1.1 MW
J: 1., 1.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 6 faults
E: ran 7 faults
J: ran max faults but better
009 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.1 MW [0.6,1.5] sec
E: 1.1 MW
J: 1., 1.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 5 faults
E: ran 4 faults
J: ran max faults during step to 1.6 MW
011 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.1 MW [0.6,1.5] sec
E: 1.1 MW
J: 1.2, 1.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 5 faults
E: ran 4 faults
J: ran max faults during step to 1.6 MW
013 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.2 MW [0.6,1.5] sec
E: 1.2 MW
J: 1.4, 1.8 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 2 faults
E: ran
J: ran 2 faults
014 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 1.6, 2.0 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 2 faults
E: ran
J: ran 2 faults
015 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 1.6, 2.0 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 1 faults
E: ran
J: ran 3 faults
016 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 1.6, 2.0 MW in steps
result: plasma, H-mode, nl_04~0.9 - early disruption
D: ran 1 faults
E: ran
J: ran 3 faults
brief 200 kJ
017 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.4 MW [0.6,1.5] sec
E: 1.4 MW
J: 2.0, 2.4 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 9 faults
E: ran 3 faults
J: ran FMIT#3 screen overload
gpc gate valve was closed
019 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 2.2 MW
result: plasma, H-mode
D: ran 5 faults
E: ran 1 fault
J: ran 4 faults
brief 207 kJ
021 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 2.4 MW
result: plasma, H-mode
D: ran 3 faults
E: ran
J: ran 9 faults

Antenna operation recovered fairly quickly after boronization. This
boronization was a lighter than the previous and the second of the
campaign. Previous campaigns had similar trends: recovery is faster
than previous boronization; the first boronization requires more time
to recover; and D and E-port antennas recover faster than J-port. A
number of high power and high stored energy discharges were achieved
and appear to be a significant improvement over discharges in the past
campaign. Perhaps the plasma shape or conditioning or some
combination of effects have improved the plasma performance. We can
follow up on these trends in the upcoming MP376. A couple of the
discharges (019) would have been better performance if the RF had not
faulted early. This suggests the shot trajectory has an impact on the
plasma performance could be important for high performance.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:19:957PM
Author: Ron Parker
;; This buffer is for notes you don't want to save, and for Lisp evaluation.
;; If you want to create a file, visit that file with C-x C-f,
;; then enter the text in that file's own buffer.

Physop Summary for 1031205

Engineering Setup and Run Plan for 12/05/03

Purpose:Boronization Recovery

Session Leader: Wukitch

Physics operator: Parker

Overnight boronization, followed by ECDC until 7:00. RF vacuum conditioning
beginning at 8:00 followed by ECDC before run begins.No bakeout other than
nominal for boronization (35 C).

Run begins at ~09:00 and ends at 17:00.

Power systems the same as on 1031204035

A-coils should be hooked up as on 1031204035

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup:All Transmitters in Run On by 07:30

Run Plan

We'll plan to run the fudicial discharge produced on the last shot of
12/04. Since this is a post-boronization run be prepared for fizzles,
duds and disruptions.

Run Summary

There was quite a long delay getting started due to 3 unrelated
problems: the Alc Server, a charging power supply and a gas leak
on Albany Street. The Alc Server went down during the night before
the run and was inoperative during the run prep. Josh and Tom got
it back up at about 10:00, thus 1 hour was lost. At that point it
was discovered that the charging power supply was not functional,
and that took approximately 2.5 hours to repair. During this time,
a leak in a gas main on Albany Street developed and we were advised
to ramp the alternator down. Fortunately the leak was capped before
the alternator speed reached below 800 RPM and we were able to bring
it back to speed without an additional loss of run time beyond that
caused by repairing the power supply.

The run itself went fairly well, considering that this was a post
boronization run, the machine having been boronized the night before.
The shots that ran were all the same current, about 1MA with a target
density of 0.9e20 m-3. Some good H-modes were obtained, particularly
early in the run. Shots 6, 7 and 9 were notable. Later in the run,
the RF was more intermittent as were the H-Modes. The maximum
stored energy reached was ~ 200 kJ at ~5 MW.

One notable feature of these discharges is that the current was driven
cleanly to zero in all but one of the shots that did not disrupt before
ramp down.

Scorecard: 20 plasma attempts, 13 useful shots (3 of which disrupted)
7 fizzles, no duds.

Session Leader Comments
Dec 5 2003 01:40:16:570PMSteve WukitchEngineering setup for Fri. 5 Dec 2003

MP#355 --- ICRF Conditioning

Session leader : Wukitch
Physics operator: Parker

Boronization overnight
ECDC for 30 minutes post antenna vacuum conditioning in D2 at 2e-4 Torr
Bake at 60 C overnight as well.

Run begins at 09:00 and ends at 17:00.

Power systems the same as on 1031204037.

A-coils should be hooked up as on 1031204037 and the power supply should be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable gatevalves (there will be no vacuum problems): ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 08:00
-------------------------------------------------------------------------------

Session Leader Run Plan:

Recondition RF antennas to power. Fiducial discharges (103120437)
will be the target plasma: BT~5.4 T, Ip~1 MA, nl_04~0.8, right gap of
1 cm.

-------------------------------------------------------------------------------

Yijun vacuum conditioned this morning post boronization
Conditioning went extremely well and faster than previous boronization
-------------------------------------------------------------------------------
Dec 5 2003 12:38:03:180PM1031205002Steve Wukitch001 -002 power cycle
Dec 5 2003 12:38:15:697PM1031205003Steve Wukitch003 NTP
Dec 5 2003 12:52:07:600PM1031205004Steve Wukitch004 NTP
Dec 5 2003 01:14:06:587PM1031205005Steve Wukitch005 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 0.25, .5, .75, 1.0 MW in steps [0.6,1.5] sec
E: 0.25, .5, .75, 1.0 MW in steps
J: 0.5, 1.0, 1.5, 2.0 MW in steps
result: plasma, H-mode, nl_04~1
D: ran faults in 1 MW step
E: ran 2 faults late
J: ran max faults
Dec 5 2003 01:35:17:447PM1031205007Steve Wukitch007 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.1 MW [0.6,1.5] sec
E: 1.1 MW
J: 1., 1.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 6 faults
E: ran 7 faults
J: ran max faults but better
Dec 5 2003 01:44:01:180PM1031205008Steve Wukitch008 NTP
Dec 5 2003 02:10:00:320PM1031205009Steve Wukitch009 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.1 MW [0.6,1.5] sec
E: 1.1 MW
J: 1., 1.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 5 faults
E: ran 4 faults
J: ran max faults during step to 1.6 MW
Dec 5 2003 02:25:56:087PM1031205010Steve Wukitch010 NTP
Dec 5 2003 02:44:15:803PM1031205011Steve Wukitch011 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.1 MW [0.6,1.5] sec
E: 1.1 MW
J: 1.2, 1.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 5 faults
E: ran 4 faults
J: ran max faults during step to 1.6 MW

Dec 5 2003 02:44:30:400PM1031205012Steve Wukitch012 NTP
Dec 5 2003 02:56:34:337PM1031205013Steve Wukitch013 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.2 MW [0.6,1.5] sec
E: 1.2 MW
J: 1.4, 1.8 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 2 faults
E: ran
J: ran 2 faults

next shot: raise RF power
Dec 5 2003 03:13:41:460PM1031205014Steve Wukitch014 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.2 MW [0.6,1.5] sec
E: 1.2 MW
J: 1.4, 1.8 MW in steps
result: plasma, H-mode, nl_04~0.9 - early disruption
D: ran 2 faults
E: ran
J: ran 2 faults

next shot: raise RF power
Dec 5 2003 03:25:10:817PM1031205015Steve Wukitch015 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 1.6, 2.0 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 1 faults
E: ran
J: ran 3 faults
Dec 5 2003 03:54:14:630PM1031205016Steve Wukitch016 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 1.6, 2.0 MW in steps
result: plasma, H-mode, nl_04~0.9 - early disruption
D: ran 1 faults
E: ran 3 faults
J: ran 1 fault
brief 200 kJ
Dec 5 2003 04:04:30:330PM1031205017Steve Wukitch017 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.4 MW [0.6,1.5] sec
E: 1.4 MW
J: 2.0, 2.4 MW in steps
result: plasma, H-mode, nl_04~0.9 - early disruption
D: ran 9 faults
E: ran 3 faults
J: ran FMIT#3 screen overload
gpc gate valve was closed
Dec 5 2003 04:27:25:107PM1031205018Steve Wukitch018 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.4 MW [0.6,1.5] sec
E: 1.4 MW
J: 2.2, 2.6 MW in steps
result: plasma, H-mode, nl_04~0.9
D: ran 5 faults
E: ran 5 faults
J: ran max faults
brief 6 MW
Dec 5 2003 04:34:37:880PM1031205019Steve Wukitch019 BT~5.4, Ip~1MA, nl_04~0.8, 1 cm gap
D: 1.3 MW [0.6,1.5] sec
E: 1.3 MW
J: 2.2 MW
result: plasma, H-mode
D: ran 5 faults
E: ran 1 fault
J: ran 4 faults
brief 207 kJ
Dec 5 2003 04:37:35:243PM1031205020Steve Wukitch20 NTP

Physics Operator Comments
Dec 5 2003 12:41:55:570PM1031205001Ron ParkerShot 1 will be a cycle test.

We have had a number of a number of unrelated problems this morning beginning with the Alc Serve 1
computer. This was resolved around 10, but then a problem with a cap charging power supply was discovered.
This was repaired and we set up for the first plasma shot at 12:30. Around 11:00 a gas leak
developed on Albany street causing us to run the alternator down as a safety measure. This turned out
not to be resonsible for any delay since the power supply was still not available when the gas leak cleared.
Dec 5 2003 12:42:49:570PM1031205002Ron ParkerShot 2 will test the repaired power supply
Dec 5 2003 12:45:49:273PM1031205003Ron ParkerShot 3 will be a plasma shot.

It turned out to be a fizzle.
Dec 5 2003 05:26:12:557PM1031205004Ron ParkerFor shot 4, 300 A was added to OH1 bringing current back to 20000 A.

Fields were better, but shot still fizzled.
Dec 5 2003 01:09:09:430PM1031205005Ron ParkerShot 5 finally went. The only change was +.9 mT was added to BR(0)
Dec 5 2003 01:24:47:023PM1031205006Ron ParkerShot 6 ran well, with a 2 MW RF pulse lasting 1 second and a steady EDA H-mode.
Dec 5 2003 01:37:30:367PM1031205007Ron ParkerThe shots continue to run well without changes.
Dec 5 2003 02:08:53:553PM1031205008Ron ParkerOops, Shot 8 was a fizzle.
Dec 5 2003 02:08:08:710PM1031205009Ron ParkerShot 9 ran well, peak RF power close to 4 MW.
Dec 5 2003 02:14:06:803PM1031205010Ron ParkerShot 10 fizzled. Every other shot mode?

Dec 5 2003 02:32:22:290PM1031205011Ron ParkerShot 11 started up well, but disrupted at 0.94 sec. BZ seems to be creeping up.
Dec 5 2003 02:41:08:850PM1031205012Ron ParkerShot 12 fizzled, expected after disruption.
Dec 5 2003 03:21:41:593PM1031205013Ron ParkerShot 13 ran OK.
Dec 5 2003 03:19:56:560PM1031205014Ron ParkerShot started up, but disrupted at 0.98 s
Dec 5 2003 03:23:05:140PM1031205015Ron ParkerSomewhat surprisingly, given that there was a disruption on the previous shot,
the shot ran well.
Dec 5 2003 04:00:36:090PM1031205016Ron ParkerShot 16 ran, but disrupted @ ~1.2 sec.


Dec 5 2003 04:02:18:140PM1031205017Ron ParkerShot 17 ran well, no disruption. Rf was intermittent.

On next shot the inner gap will be increased 1 cm, the outer gap will be held
approximately constant.
Dec 5 2003 05:20:45:793PM1031205018Ron ParkerShot 18 ran well, off the inner limiter.
Dec 5 2003 05:22:16:310PM1031205019Ron ParkerShot 19 ran well. RF intermittent.
Dec 5 2003 04:39:21:087PM1031205020Ron ParkerShot 20 fizzled.
Dec 5 2003 05:09:51:873PM1031205021Ron ParkerShot 21 ran well.
Dec 5 2003 05:08:17:733PM1031205022Ron ParkerAlas, the last shot fizzled!

Engineering Operator Comments
ShotTimeTypeStatusComment
112:00:54:740PMTestOk
212:23:58:523PMTestOk
312:32:40:570PMPlasmaOk
412:50:01:913PMPlasmaOk
501:02:50:837PMPlasmaOk
601:15:37:587PMPlasmaOk
701:28:24:180PMPlasmaOk
801:41:06:163PMPlasmaOk
901:56:37:680PMPlasmaOk
1002:09:06:507PMPlasmaOk
1102:21:38:007PMPlasmaOk
1202:35:01:430PMPlasmaOk
1302:47:44:430PMPlasmaOk
1403:00:23:757PMPlasmaOk
1503:18:23:137PMPlasmaOk
1603:37:48:720PMPlasmaOk
1703:53:41:550PMPlasmaOk
1804:09:20:397PMPlasmaOk
1904:22:00:223PMPlasmaOk
2004:35:24:913PMPlasmaOk
2104:48:05:443PMPlasmaOk
2205:01:14:770PMPlasmaOk