Alcator C-Mod Run 1031216 Information

Back to runs

Miniproposals
Miniproposal:355
Date Filed:11/12/2003
Title:ICRF Testing & Conditioning
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-7)
Miniproposal:377
Date Filed:11/26/2003
Title:Energy confinement in double-null discharges
First Author:Dale Meade
Session Leader:Dale Meade (shots 8-21)
Session Leader:Earl Marmar (shots 8-21)

Operators
Session leader(s):Steve Wukitch,Earl Marmar,Dale Meade
Physics operator(s):Robert Granetz
Engineering operator(s):Ed Fitzgerald,Bill Parkin,Gary Dekow

Engineering Operator Run Comment
MP 355 ICRF & MP 377; SL:Wukitch, Marmar PO:Granetz EO:Dekow/Fitz/Parkin

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:35:460PM
Author: Earl Marmar
Engineering setup for Tuesday, 16 Dec 2003

MP 355 ICRF post-boron conditioning
MP 377 Energy confinement in double-null (standby)

Session leader: S. Wukitch (MP 355), E. Marmar (MP 377)
Physics operator: R. Granetz

ECDC overnight in D2 at 2e-4 Torr, stopping by 07:00.
Bake at 60 C overnight as well.

*********
* NOTE: * Run begins at 08:00 and ends at 15:00, due to the PSFC holiday party.
********* ----- -----

Power systems the same as on 1031204037 (fiducial discharge, 1.0 MA, 5.4 T,
lower single null).

A-coils should be hooked up as on 1031204037 (+Dtop -Dbot -Jtop +Jbot), and
the power supply should be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 07:00 (note earlier time)

-------------------------------------------------------------------------------
Run Plan:

Boronization recovery: using the 1 MA fiducial shot (1031204037), get all
the transmitters/antennas going again at full power.

If that goes as fast as last time, then we will change to double null
plasmas and take up where we left off on MP 377.
-------------------------------------------------------------------------------
NTP 003, 013, 018

001 BT~5.4 T, Ip~ 1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran
E: ran
J: did not run - no bira demand
002 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran
E: ran 1 fault
J: ran no J3
004 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran
E: ran
J: ran 9 faults
005 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran 2 faults
E: ran
J: ran 2 faults
006 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial plasma with constant RF power
D: 1.0 MW [0.6,1.5]sec
E: 1.0 MW [0.6,1.5]sec
J: 2.0 MW [0.6,1.5]sec
result: plasma
D: ran 7 faults
E: ran
J: ran 6 faults
next shot: repeat
007 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial plasma with constant RF power
D: 1.0 MW [0.6,1.5]sec
E: 1.0 MW [0.6,1.5]sec
J: 2.0 MW [0.6,1.5]sec
result: plasma
D: ran 7 faults
E: ran
J: ran
next shot: move to MP 377 1031211016

Run Summary

We did no vacuum conditioning on D-port antenna but its recovery was
not remarkably worse than E-port. We had data problems on J-port for
001-004 and these have been fixed (001 had no J-port, 002 had no J3,
and 003 was NTP). Otherwise the recovery was fairly painless.

When F-side neutral pressure reached 0.3 we started to have more
faulting on all antennas but particularly D and J-port.

Physics Operator Summaries
Entered: Jul 7 2004 04:37:20:067PM
Author: Robert Granetz
Physics operator summary for run 1031216 (Tuesday):

MP 355 ICRF post-boron conditioning
MP 377 Energy confinement in double-null (standby)

Session leader: S. Wukitch (MP 355), E. Marmar (MP 377)
Physics operator: R. Granetz

Summary: Despite a slow start because of RF data acquisition and other
problems, the boronization recovery of both the machine and the RF
was quick, and MP 355 was declared done after shot 7. We then
switched to the double-null MP 377. We ran 1.0 and 1.2 MA, and
target densities from 0.8 to 1.4e20 m-2. The machine continued to
run very well, with only two fizzles. RF power got as high as 6 MW,
but J-port antenna does not run well at higher densities. See the
session leaders' summaries for physics learned on this MP.

There was a problem with the EF3 breaker on shot 3, which caused a
dud, and there was a TF crowbar at the end of shot 19, which blew
one fuse.

Scorecard: 18 plasmas
2 fizzles
1 dud
0 test or no-power shot cycle
0 aborted and/or screwed up by computer problems
----------
21 total

-------------------------------------------------------------------------------
Engineering setup for Tuesday, 16 Dec 2003

MP 355 ICRF post-boron conditioning
MP 377 Energy confinement in double-null (standby)

Session leader: S. Wukitch (MP 355), E. Marmar (MP 377)
Physics operator: R. Granetz

ECDC overnight in D2 at 2e-4 Torr, stopping by 07:00.
Bake at 60 C overnight as well.

*********
* NOTE: * Run begins at 08:00 and ends at 15:00, due to the PSFC holiday party.
********* ----- -----

Power systems the same as on 1031204037 (fiducial discharge, 1.0 MA, 5.4 T,
lower single null).

A-coils should be hooked up as on 1031204037 (+Dtop -Dbot -Jtop +Jbot), and
the power supply should be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 07:00 (note earlier time)

-------------------------------------------------------------------------------
Run Plan:

Boronization recovery: using the 1 MA fiducial shot (1031204037), get all
the transmitters/antennas going again at full power.

If that goes as fast as last time, then we will change to double null
plasmas and take up where we left off on MP 377.

-------------------------------------------------------------------------------

Boronization was done last evening.
ECDC in helium was done overnight, but no 60 C bake.

Hybrid coldstart done by the engineering group; no errors found

Loaded PCS segment 1 from 1031212024 (most recent shot).
Loaded PCS segment 2 from 1031204037 (1 MA, 5.4 T fiducial).

-------------------------------------------------------------------------------

The start of the run will be delayed while the RF tries to get some vacuum
conditioning done. This will be followed by some ECDC in D2.

Shot 01 -- Plasma. Good shot. 1.0 MA fiducial. Bruce just informed me that
the gate valve should have been set to remained closed on the
fiducial, which was news to me. Prf=2+ MW (D and E). One H-mode.
Startup just barely made it.

Next shot: reduce pre-fill by 1 ms. Set main gate valve to remain
closed for 8 minutes after the shot (at Bruce's request).

Shot 02 -- Plasma. Another good shot. D and E are good; still no J-port
power. Longer H-mode. 120 kJ with 2.3 MW of RF. Zeff=1.5.
Very low carbon light during startup.

Next shot: repeat, no PCS changes

Shot 03 -- Dud. No EF3. Problem with EF3 breaker.

Next shot: repeat, no PCS changes

Shot 04 -- Plasma. Good shot. All three antenna systems are working, but the
data acquisition for J-port is not working, so we don't know how
much power it's radiating. It's presumably comparable to D and E,
which would make Prf about 4.5 MW. Two H-modes, with Wth=160 kJ.

Next shot: repeat, with slight tweak on Br_0

Shot 05 -- Plasma. Good shot. All antennas and transmitters are working.
Prf=4.5 MW. Long EDA H-mode.

Next shot: no PCS changes. RF will change from a stepped waveform
to a simple flat waveform at 4.5 MW

Shot 06 -- Plasma. Good shot. Prf=4.5 MW, but with lots of faulting on J3 and
J4.

Next shot: repeat, no PCS changes

Shot 07 -- Plasma. Good shot. Prf=4.6 MW, with some faulting on D. Success
declared on the boronization recovery (MP 355).

Next shot: load a recent double null shot (1031211016), except
keep segment 1 from the present shot, and begin MP 377.

NOTE: the active segment is #4 !!

Shot 08 -- Plasma. Good shot. Nearly double null, but actually more upper
single null. Disrupted halfway down the rampdown. Prf=4.6 MW,
with lots of faulting. RF pulse goes from t=0.6 to 1.0 s. H-mode.
Wth=170 kJ. Lots of large m=1/n=1 at the H-L backtransition.

Next shot: tweak the SSEP gain to remove the rampdown disruption.
RF programming is also being changed.

Shot 09 -- Plasma. Good shot. Ramped all the way down. Prf=4.5 MW until
t=1.0 s (with no faults), and then started ramping up to 6 MW, but
with lots of faulting on J3 and J4.

Next shot: no PCS change, but delay the RF pulse by 100 ms at the
request of John Rice.

Shot 10 -- Plasma. Good shot. RF looked the same, except for the 100 ms
shift.

Next shot: no PCS changes, but lower the J-port RF power by 50%.

Shot 11 -- Plasma. Good shot. Prf=3.3 MW flat, then ramping up to 6 MW with
only one fault. SSEP=+2 mm, kappa=1.73, delta_L=0.45, delta_U=0.65,
inner gap=2.0 cm, outer gap=1.1-1.4 cm. nl_04 (target)=0.9e20 m-2,
Ip=1.04 MA, Btor=5.4 T. Wth peaks at 190 kJ at peak RF power.

Next shot: repeat, no changes

Shot 12 -- Plasma. Good shot. There was a big chunk taken out of the plasma
current between t=0.1-0.2 s. Wth=200 kJ. Peak Rdd>1.0e14 s-1.

Next shot: no PCS changes; keep RF on for another 100 ms

Shot 13 -- Fizzle.

Next shot: reduce pre-fill gas puff by 1 ms

Shot 14 -- Plasma. Good shot. The RF pulse is lasting longer than the
current flattop.

Next shot: increase flattop to t=1.5 s (from 1.3 s).

Shot 15 -- Plasma. Good shot. Current flattop now goes to t=1.5 s. The Btor
flattop still needs to be extended, however. J-port trips out
at t=1.35 s.

Next shot: raise Ip to 1.25 MA and nl_04 to 1.0e20 m-2. Also extend
Btor flattop to t=1.5 s.

Shot 16 -- Plasma. Good shot. Ip=1.23 MA. Flattop goes to t=1.5 s. RF
doesn't like the higher density. nl_04=1.04e20 m-2. Much of the
engineering data did not come through, so no EFITs.

Next shot: increase nl_04 to 1.2e20 m-2

Shot 17 -- Plasma. Good shot. nl_04(target)=1.2e20 m-2. Ip=1.22 MA.

Next shot: reduce SSEP by 2 mm. Also reduce argon puff by 2 ms (at
John Rice's request!!)

Shot 18 -- Fizzle.

Next shot: reduce Br_0 by 0.5 mT. Also reduced argon puff by
another 10 ms (to 30 ms) at Earl's request.

Shot 19 -- Plasma. Good shot. TF crowbarred. This equilibrium was much more
"double-null"-like than previous shots today. Wth reaches 170 kJ.

Next shot: increase nl_04 to 1.4e20 m-2 and return SSEP to its
value before shot 19.

The next shot will be delayed while a fuse is changed.

Shot 20 -- Plasma. Good shot. Back to the slightly (magnetically) unbalanced
double null. nl_04(target)=1.4e20 m-2. J-port didn't go (because
of the higher density). Wth=130-140 kJ with Prf=2-3 MW.

Next shot: no changes

Shot 21 -- Plasma. Good shot. Pretty much a repeat of the previous shot.
J-port still didn't go. Wth=155 kJ, Prf=3 MW.

End of run

Session Leader Comments
Dec 16 2003 11:23:00:270AM1031216001Steve Wukitch001 BT~5.4 T, Ip~ 1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran
E: ran
J: did not run - no bira demand
Dec 16 2003 11:22:45:690AM1031216002Steve Wukitch002 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran
E: ran 1 fault
J: ran no J3
Dec 16 2003 11:22:33:097AM1031216003Steve Wukitch003 NTP
Dec 16 2003 11:20:43:943AM1031216004Steve Wukitch004 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran
E: ran
J: ran 9 faults
Dec 16 2003 11:00:45:513AM1031216005Steve Wukitch005 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial
D: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
E: 0.25, 0.5, .75, 1. MW steps [0.6,1.5]sec
J: 0.5, 1.0, 1.5, 2. MW steps [0.6,1.5]sec
result: plasma
D: ran 2 faults
E: ran
J: ran 2 faults
Dec 16 2003 11:18:10:213AM1031216006Steve Wukitch006 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial plasma with constant RF power
D: 1.0 MW [0.6,1.5]sec
E: 1.0 MW [0.6,1.5]sec
J: 2.0 MW [0.6,1.5]sec
result: plasma
D: ran 7 faults
E: ran
J: ran 6 faults
next shot: repeat
Dec 16 2003 11:31:55:977AM1031216007Steve Wukitch007 BT~5.4T, Ip~1 MA, nl04~0.8 - fiducial plasma with constant RF power
D: 1.0 MW [0.6,1.5]sec
E: 1.0 MW [0.6,1.5]sec
J: 2.0 MW [0.6,1.5]sec
result: plasma
D: ran 7 faults
E: ran
J: ran
next shot: move to MP 377 1031211016
Dec 16 2003 11:52:33:750AM1031216008Dale MeadeMeade just arrived. Shot 1031216008 was to be a repeat of 1031211016.
Dec 16 2003 11:53:30:703AM1031216008Earl Marmarswitching to mp377 after boron recovery

start with reload of 1031211016, DN (SSEP ~ +0.2 cm)

plasma, some rf trips
Wmax = 177 kJ, H89 ~ 1.5 (but trips complicate interpreptation)
Dec 16 2003 12:03:44:470PM1031216009Dale MeadeH89 = 1.64 at first h-mode
Dec 16 2003 12:05:36:377PM1031216009Earl Marmarrepeat
plasma; steady RF

3 H-modes; looking ELM-free

3'rd H-Mode coming almost to a steady-state, H89 ~ 1.4
Wmax = 179 kJ
Dec 16 2003 12:35:00:483PM1031216011Dale MeadeH89 = 1.56 for the first h-mode , the second H-mode is staedy at ~ 1.5
Dec 16 2003 12:56:07:303PM1031216011Earl Marmarlower RF power early (3 MW) then ramp up to 6 MW

first H-mode: Wmax = 164 kJ (3 MW), H89 ~ 1.6 (when dW/dt = 0)
Dec 16 2003 12:46:21:797PM1031216012Dale MeadeThe third H-mode was best H89 = 1.56 @ PRF = 6.14 MW
Dec 16 2003 12:53:19:947PM1031216012Earl Marmarrepeat
plasma
3'rd H-mode with RF ramp to 6 MW gives H89 ~ 1.55, Wmax = 200 kJ
Dec 16 2003 01:51:45:893PM1031216017Earl Marmar1.2 MA
Plasma

Wmax = 178 kJ, Prf = 3.4 MW

H89 ~ 1.34 (at dW/dt = 0)
Dec 16 2003 03:02:16:080PM1031216020Earl Marmarnl_04 target to 1.4e20

plasma; lower RF power (no J-port)
barely into H-mode at 2.2 MW


Physics Operator Comments
Dec 14 2003 10:44:51:020PMRobert GranetzEngineering setup for Tuesday, 16 Dec 2003

MP 355 ICRF post-boron conditioning
MP 377 Energy confinement in double-null (standby)

Session leader: S. Wukitch (MP 355), E. Marmar (MP 377)
Physics operator: R. Granetz

ECDC overnight in D2 at 2e-4 Torr, stopping by 07:00.
Bake at 60 C overnight as well.

*********
* NOTE: * Run begins at 08:00 and ends at 15:00, due to the PSFC holiday party.
********* ----- -----

Power systems the same as on 1031204037 (fiducial discharge, 1.0 MA, 5.4 T,
lower single null).

A-coils should be hooked up as on 1031204037 (+Dtop -Dbot -Jtop +Jbot), and
the power supply should be enabled.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB

-------------------------------------------------------------------------------
RF Setup: All 4 transmitters in Run On by 07:00 (note earlier time)

-------------------------------------------------------------------------------
Run Plan:

Boronization recovery: using the 1 MA fiducial shot (1031204037), get all
the transmitters/antennas going again at full power.

If that goes as fast as last time, then we will change to double null
plasmas and take up where we left off on MP 377.
Dec 16 2003 07:52:02:510AMRobert Granetz Boronization was done last evening.
ECDC in helium was done overnight, but no 60 C bake.

Hybrid coldstart done by the engineering group; no errors found

Loaded PCS segment 1 from 1031212024 (most recent shot).
Loaded PCS segment 2 from 1031204037 (1 MA, 5.4 T fiducial).
Dec 16 2003 08:14:57:860AMRobert GranetzThe start of the run will be delayed while the RF tries to get some vacuum
conditioning done. This will be followed by some ECDC in D2.
Dec 16 2003 10:08:19:307AM1031216001Robert GranetzShot 01 -- Plasma. Good shot. 1.0 MA fiducial. Bruce just informed me that
the gate valve should have been set to remained closed on the
fiducial, which was news to me. Prf=2+ MW (D and E). One H-mode.
Startup just barely made it.

Next shot: reduce pre-fill by 1 ms. Set main gate valve to remain
closed for 8 minutes after the shot (at Bruce's request).
Dec 16 2003 10:10:41:913AM1031216002Robert GranetzShot 02 -- Plasma. Another good shot. D and E are good; still no J-port
power. Longer H-mode. 120 kJ with 2.3 MW of RF. Zeff=1.5.
Very low carbon light during startup.

Next shot: repeat, no PCS changes
Dec 16 2003 10:15:04:660AM1031216003Robert GranetzShot 03 -- Dud. No EF3. Problem with EF3 breaker.

Next shot: repeat, no PCS changes
Dec 16 2003 10:43:31:033AM1031216004Robert GranetzShot 04 -- Plasma. Good shot. All three antenna systems are working, but the
data acquisition for J-port is not working, so we don't know how
much power it's radiating. It's presumably comparable to D and E,
which would make Prf about 4.5 MW. Two H-modes, with Wth=160 kJ.

Next shot: repeat, with slight tweak on Br_0
Dec 16 2003 11:01:37:090AM1031216005Robert GranetzShot 05 -- Plasma. Good shot. All antennas and transmitters are working.
Prf=4.5 MW. Long EDA H-mode.

Next shot: no PCS changes. RF will change from a stepped waveform
to a simple flat waveform at 4.5 MW
Dec 16 2003 11:20:25:367AM1031216006Robert GranetzShot 06 -- Plasma. Good shot. Prf=4.5 MW, but with lots of faulting on J3 and
J4.

Next shot: repeat, no PCS changes
Dec 16 2003 11:34:29:943AM1031216007Robert GranetzShot 07 -- Plasma. Good shot. Prf=4.6 MW, with some faulting on D. Success
declared on the boronization recovery (MP 355).

Next shot: load a recent double null shot (1031211016), except
keep segment 1 from the present shot, and begin MP 377.

NOTE: the active segment is #4 !!
Dec 16 2003 11:49:33:143AM1031216008Robert GranetzShot 08 -- Plasma. Good shot. Nearly double null, but actually more upper
single null. Disrupted halfway down the rampdown. Prf=4.6 MW,
with lots of faulting. RF pulse goes from t=0.6 to 1.0 s. H-mode.
Wth=170 kJ. Lots of large m=1/n=1 at the H-L backtransition.

Next shot: tweak the SSEP gain to remove the rampdown disruption.
RF programming is also being changed.
Dec 16 2003 11:57:34:260AM1031216009Robert GranetzShot 09 -- Plasma. Good shot. Ramped all the way down. Prf=4.5 MW until
t=1.0 s (with no faults), and then started ramping up to 6 MW, but
with lots of faulting on J3 and J4.

Next shot: no PCS change, but delay the RF pulse by 100 ms at the
request of John Rice.
Dec 16 2003 12:11:43:027PM1031216010Robert GranetzShot 10 -- Plasma. Good shot. RF looked the same, except for the 100 ms
shift.

Next shot: no PCS changes, but lower the J-port RF power by 50%.
Dec 16 2003 12:33:55:500PM1031216011Robert GranetzShot 11 -- Plasma. Good shot. Prf=3.3 MW flat, then ramping up to 6 MW with
only one fault. SSEP=+2 mm, kappa=1.73, delta_L=0.45, delta_U=0.65,
inner gap=2.0 cm, outer gap=1.1-1.4 cm. nl_04 (target)=0.9e20 m-2,
Ip=1.04 MA, Btor=5.4 T. Wth peaks at 190 kJ at peak RF power.

Next shot: repeat, no changes
Dec 16 2003 12:54:57:443PM1031216012Robert GranetzShot 12 -- Plasma. Good shot. There was a big chunk taken out of the plasma
current between t=0.1-0.2 s. Wth=200 kJ. Peak Rdd>1.0e14 s-1.

Next shot: no PCS changes; keep RF on for another 100 ms
Dec 16 2003 12:54:26:240PM1031216013Robert GranetzShot 13 -- Fizzle.

Next shot: reduce pre-fill gas puff by 1 ms
Dec 16 2003 01:10:54:630PM1031216014Robert GranetzShot 14 -- Plasma. Good shot. The RF pulse is lasting longer than the
current flattop.

Next shot: increase flattop to t=1.5 s (from 1.3 s).
Dec 16 2003 01:20:39:180PM1031216015Robert GranetzShot 15 -- Plasma. Good shot. Current flattop now goes to t=1.5 s. The Btor
flattop still needs to be extended, however. J-port trips out
at t=1.35 s.

Next shot: raise Ip to 1.25 MA and nl_04 to 1.0e20 m-2. Also extend
Btor flattop to t=1.5 s.
Dec 16 2003 01:38:55:707PM1031216016Robert GranetzShot 16 -- Plasma. Good shot. Ip=1.23 MA. Flattop goes to t=1.5 s. RF
doesn't like the higher density. nl_04=1.04e20 m-2. Much of the
engineering data did not come through, so no EFITs.

Next shot: increase nl_04 to 1.2e20 m-2
Dec 16 2003 01:48:15:070PM1031216017Robert GranetzShot 17 -- Plasma. Good shot. nl_04(target)=1.2e20 m-2. Ip=1.22 MA.

Next shot: reduce SSEP by 2 mm. Also reduce argon puff by 2 ms (at
John Rice's request!!)
Dec 16 2003 02:05:05:410PM1031216018Robert GranetzShot 18 -- Fizzle.

Next shot: reduce Br_0 by 0.5 mT. Also reduced argon puff by
another 10 ms (to 30 ms) at Earl's request.
Dec 16 2003 02:28:16:540PM1031216019Robert GranetzShot 19 -- Plasma. Good shot. TF crowbarred. This equilibrium was much more
"double-null"-like than previous shots today. Wth reaches 170 kJ.

Next shot: increase nl_04 to 1.4e20 m-2 and return SSEP to its
value before shot 19.
Dec 16 2003 02:48:19:483PM1031216019Robert GranetzThe next shot will be delayed while a fuse is changed.
Dec 16 2003 02:57:58:007PM1031216020Robert GranetzShot 20 -- Plasma. Good shot. Back to the slightly (magnetically) unbalanced
double null. nl_04(target)=1.4e20 m-2. J-port didn't go (because
of the higher density). Wth=130-140 kJ with Prf=2-3 MW.

Next shot: no changes
Dec 16 2003 03:06:27:137PM1031216021Robert GranetzShot 21 -- Plasma. Good shot. Pretty much a repeat of the previous shot.
J-port still didn't go. Wth=155 kJ, Prf=3 MW.

End of run

Engineering Operator Comments
ShotTimeTypeStatusComment
109:23:49:970AMPlasmaOk
209:55:39:040AMPlasmaOk
310:11:05:290AMPlasmaOk
410:27:07:443AMPlasmaOk
510:53:56:193AMPlasmaOk
611:12:08:390AMPlasmaOk
711:24:50:093AMPlasmaOk
811:38:02:017AMPlasmaOk
911:51:31:643AMPlasmaOk
1012:04:13:660PMPlasmaOk
1112:16:40:223PMPlasmaOk
1212:33:54:500PMPlasmaOk
1312:46:40:140PMPlasmaOk
1412:59:15:317PMPlasmaOk
1501:11:49:440PMPlasmaOk
1601:24:16:177PMPlasmaOk
1701:38:48:173PMPlasmaOk
1801:51:39:677PMPlasmaOk
1902:04:36:397PMPlasmaBadTF comm fault at +2.7 seconds
2002:44:50:427PMPlasmaOk
2102:58:30:350PMPlasmaOk