| Operators | |
| Session leader(s): | Martin Greenwald |
| Physics operator(s): | Steve Wolfe |
| Engineering operator(s): | Bill Parkin,Gary Dekow,Bill Cochran |
| Engineering Operator Run Comment |
| MP# 305 Hysteresis in ITB (off- vs on-axis power)/Wolfe/[g]/Cochran/Deko |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:03:943PM |
| Author: Martin Greenwald |
| Run Summary for MP 305 ITB access conditions and hysteresis Session Leader - Greenwald Phys Op - Wolfe Plan: Run at 5.55 T, 0.8 MA, standard shape The principal variation is in the RF programming - back transition - 1. Begin with 2-3 MW at 70 MHz steady, beginning at 0.6 sec, establish ITB 2. Assuming the barrier forms promptly, begin ramping power at 0.9 seconds 70 MHz ramps down to reach 0.5 MW at 1.5 second 80 MHz ramps up at identical rate to keep total power fixed 3. Assuming barrier is quenched sometime during the ramp, adjust timing and ramp rate to get more precise measure of back transition threshold - forward transition - 4. Begin with about 1.25 MW in each of 70 and 80 MHz, start at 0.6 sec ramp 80 down - at rate which will reach 0 MW at 1.1 seconds ramp 70 up - at same rate - keep total power constant (after 1.1 seconds keep 70 flat til 1.5 seconds) 5. Assuming barrier forms at some point during ramp, adjust timing at ramp rates to get more precise measure of forward threshold Results: Not very productive. We had trouble getting barriers with the planned scenario. We had weak ITBs on 014 and 015 but with early back transition. Putting on central power should have helped reduce impurity build-up and sustained the barriers, but we got no barriers at all in these cases. Starting with shot 024 we dropped the field to 4.55 and switched the RF waveforms. (This is our nominal ITB scenario). We had better luck getting ITBs but were still not able to sustain them. The results were similar to yesterday's run. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:49:600PM |
| Author: Steve Wolfe |
| Physics Operator Summary for Wed. 3/24/2004 MP#305 ITB Hysteresis SL: Greenwald PO: Wolfe EO: Cochran,Dekow,Parkin Engineering setup: ------------------ ECDC overnight in D2, stopping two hours before the run. Run begins at 09:00, ends at 17:00 Power supplies as on 1040323017 Gas System Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid enabled (PG1) leave B-side upper with 15 psi He3 Hybrid DISABLED (PG2) fill C-side with 30 psi D2 Hybrid enabled (PG3) fill NINJA (lower cap) leave as is Gate valve permissives for the usual suspects (ECE, VUV, DNB) assuming no vacuum problems RF: Transmitters #1,2,3 and 4 in RUN-ON by 08:30 Run Plan: --------- Load from any shot from 1040323. Change tf current program in seg2 to 154kA, aiming for Btor=5.55T. Set nl04 program to 0.8 or 0.9e20. 1. Begin with 2-3 MW at 70 MHz steady, beginning at 0.6 sec, establish ITB 2. Assuming the barrier forms promptly, begin ramping power at 0.9 seconds 70 MHz ramps down to reach 0.5 MW at 1.5 second 80 MHz ramps up at identical rate to keep total power fixed 3. Assuming barrier is quenched sometime during the ramp, adjust timing and ramp rate to get more precise measure of back transition threshold - forward transition - 4. Begin with about 1.25 MW in each of 70 and 80 MHz, start at 0.6 sec ramp 80 down - at rate which will reach 0 MW at 1.1 seconds ramp 70 up - at same rate - keep total power constant (after 1.1 seconds keep 70 flat til 1.5 seconds) 5. Assuming barrier forms at some point during ramp, adjust timing at ramp rates to get more precise measure of forward threshold Results --------- The machine ran pretty well today, but we didn't get much out of the MP. We started with low-field side resonance, as planned. The first real sign of an ITB did not come until shot 14, after a lot of trouble getting the RF to stay on. On shot#15 we got what looked like a good ITB starting before 1sec, so we started the ramp program. However, we then saw no more convincing ITB's, even with the central power delayed significantly and at low ramp rates, and with the off-axis rf started earlier, at .5sec. On shot#24 we gave up on the low field resonance and went back to 4.5T, with D+E off-axis. With this setup we got two h-modes, each with ITB's and radiating to an H-L in each case. Turning on the ramps failed to stop the first ITB from radiating away, but prevented formation of an ITB in the second H-mode. This was the case for all ramp rates tried. Late in the run we ran into serious slowdowns in the data cycle. Josh thinks there was a network problem, but as of this writing it has not been tracked down. The symptom is that the data stores were a factor of about five longer than normal. INIT was also slow. I didn't need to touch the startup all day. I did play around some with the glitch at segment switch, and got some improvement by increasing the current program for the first two points in seg2, and moving the second point earlier. However, this did not prevent the glitch/injection in all cases. I did note that all the Xpoint locations see a substantial error signal at seg switch, and would possibly be better if they were changed to there values later in the shot. I also noticed that the ip offset in seg2 is presently set to -15000 instead of the more recent value of -30000. I didn't bother to fix this. Scorecard ---------- tests/no-power 2 duds 0 fizzles 0 plasmas 29 ========== == Shots 31 After the run additional cycles were taken and Josh and Henry determined that a network switch had a mismatch that seems to have been the cause of the data slowdown. |
| Session Leader Comments | |||
| Mar 24 2004 08:35:44:610AM | Martin Greenwald | MP 305 ITB access conditions and hysteresis Session Leader - Greenwald Phys Op - Wolfe Run at 5.55 T, 0.8 MA, standard shape The principal variation is in the RF programming - back transition - 1. Begin with 2-3 MW at 70 MHz steady, beginning at 0.6 sec, establish ITB 2. Assuming the barrier forms promptly, begin ramping power at 0.9 seconds 70 MHz ramps down to reach 0.5 MW at 1.5 second 80 MHz ramps up at identical rate to keep total power fixed 3. Assuming barrier is quenched sometime during the ramp, adjust timing and ramp rate to get more precise measure of back transition threshold - forward transition - 4. Begin with about 1.25 MW in each of 70 and 80 MHz, start at 0.6 sec ramp 80 down - at rate which will reach 0 MW at 1.1 seconds ramp 70 up - at same rate - keep total power constant (after 1.1 seconds keep 70 flat til 1.5 seconds) 5. Assuming barrier forms at some point during ramp, adjust timing at ramp rates to get more precise measure of forward threshold | |
| Mar 24 2004 05:59:42:670PM | Martin Greenwald | Results: Not very productive. We had trouble getting barriers with the planned scenario. We had weak ITBs on 014 and 015 but with early back transition. Putting on central power should have helped reduce impurity build-up and sustained the barriers, but we got no barriers at all in these cases. Starting with shot 024 we dropped the field to 4.55 and switched the RF waveforms. (This is our nominal ITB scenario). We had better luck getting ITBs but were still not able to sustain them. The results were similar to yesterday's run. | |
| Mar 24 2004 09:13:15:730AM | 1040324001 | Martin Greenwald | Plasma - RF not tuned yet no H-mode, no ITB |
| Mar 24 2004 09:23:12:777AM | 1040324002 | Martin Greenwald | Good Plasma - RF power still low |
| Mar 24 2004 09:41:19:773AM | 1040324003 | Martin Greenwald | RF up to 1 MW brief H-mode |
| Mar 24 2004 09:53:03:400AM | 1040324004 | Martin Greenwald | Prf to 1 MW brief H-mode |
| Mar 24 2004 10:09:28:003AM | 1040324005 | Martin Greenwald | RF cleaning up - power to 1.5 MW - lasts longer two h-mode phases hint of ITB on second H-mode |
| Mar 24 2004 10:24:33:510AM | 1040324006 | Martin Greenwald | RF power reaches 2 MW H-mode for 0.3 sec |
| Mar 24 2004 10:39:46:927AM | 1040324007 | Martin Greenwald | disruption at 1.4 sec - spark from J antenna? two brief h-modes |
| Mar 24 2004 10:56:28:890AM | 1040324008 | Martin Greenwald | RF up to 2 MW (still ramping at beginning) H-mode but no ITB |
| Mar 24 2004 11:09:21:470AM | 1040324009 | Martin Greenwald | RF still ragged h-modes but no ITB |
| Mar 24 2004 11:27:04:310AM | 1040324010 | Martin Greenwald | breaker problem |
| Mar 24 2004 11:47:17:013AM | 1040324011 | Martin Greenwald | Bt raised to 5.62 T otherwise results similar to 09 |
| Mar 24 2004 11:59:25:110AM | 1040324012 | Martin Greenwald | Multiple H-modes, RF trips Hint of ITB at 1.2-1.3 sec? |
| Mar 24 2004 12:11:14:637PM | 1040324013 | Martin Greenwald | No power test |
| Mar 24 2004 12:26:08:440PM | 1040324014 | Martin Greenwald | RF steady at 2 MW weak itb beginning at 1.2 sec |
| Mar 24 2004 12:40:36:010PM | 1040324015 | Martin Greenwald | Power to 2.2 MW Good ITB - starts at about 0.95 sec |
| Mar 24 2004 12:56:35:143PM | 1040324016 | Martin Greenwald | First shot with RF ramps started 80 MHz (on-axis) at 1 sec no evidence of itb |
| Mar 24 2004 01:10:33:133PM | 1040324017 | Martin Greenwald | reduced ramp rate still no sign of itb |
| Mar 24 2004 01:27:29:927PM | 1040324018 | Martin Greenwald | ramp delayed til 1.1 sec still no ITB |
| Mar 24 2004 01:42:00:040PM | 1040324019 | Martin Greenwald | early trips on RF (tried to get a bit more power) no itb |
| Mar 24 2004 02:00:36:790PM | 1040324020 | Martin Greenwald | RF cleaner - but still early trip no itb |
| Mar 24 2004 02:16:17:203PM | 1040324021 | Martin Greenwald | Early disruption - before 0.9 sec |
| Mar 24 2004 02:29:07:457PM | 1040324022 | Martin Greenwald | Steady H-mode but no sign of ITB |
| Mar 24 2004 03:23:10:697PM | 1040324024 | Martin Greenwald | Switched to 4.55 T (reversing role of 70 & 80 MHz) Got decent itbs - interupted by back transition |
| Mar 24 2004 03:23:37:493PM | 1040324025 | Martin Greenwald | Started RF ramp didn't save first itb which still collapsed second was much weaker |
| Mar 24 2004 04:03:49:040PM | 1040324026 | Martin Greenwald | More power into J Similar to shot 25 |
| Mar 24 2004 04:03:30:603PM | 1040324028 | Martin Greenwald | more power into J similar result - back transition at 1.05 |
| Mar 24 2004 04:19:43:330PM | 1040324029 | Martin Greenwald | same as last shot |
| Mar 24 2004 05:15:43:993PM | 1040324031 | Martin Greenwald | J port moved earlier - to 0.7 sec no itb at all |
| Physics Operator Comments | |||
| Mar 24 2004 08:18:57:770AM | Steve Wolfe | PCS Setup for 1040324 Load from 1040323036 Raise tf current in seg2 to -154000 Contrary to run plan, leave nl04 at 1e20, since this shot did run well. Adjust second seg2 ip point to [.15,-.8e6] Load at 24-Mar-2004 08:18:48.00 Open tree /home/wolfe/pcs_scratch -1 Open tree done | |
| Mar 24 2004 09:08:33:987AM | 1040324001 | Steve Wolfe | shot#1: plasma full length. Hardly any RF. F-side pressure is a little high. B-field is a tad high:5.61 vs 5.55 next shot: decrease tf current to -152100 |
| Mar 24 2004 09:22:22:820AM | 1040324002 | Steve Wolfe | shot#2: decrease tf current to -152100 plasma full length, still no rf. next shot: drop nl04 to 0.9e20 |
| Mar 24 2004 09:40:37:910AM | 1040324003 | Steve Wolfe | shot#3: drop nl04 to 0.9e20 plasma full length, brief h-mode(?) RF faulting above 1MW. |
| Mar 24 2004 09:53:21:463AM | 1040324004 | Steve Wolfe | shot#4: No pcs changes; RF trying to improve match. plasma full length, rf still tripping at the L-H transition |
| Mar 24 2004 10:05:44:217AM | 1040324005 | Steve Wolfe | shot#5: No pcs changes; RF trying to improve match. plasma full length,two h-modes this time. |
| Mar 24 2004 10:23:31:273AM | 1040324006 | Steve Wolfe | shot#6: No pcs changes; RF trying to improve match. plasma full length, two hmodes, first one lasts longer. No ITB. |
| Mar 24 2004 10:39:02:923AM | 1040324007 | Steve Wolfe | shot#7: No pcs changes; plasma disrupted at 1.37sec arcs and sparks at J-port antenna. |
| Mar 24 2004 10:55:43:950AM | 1040324008 | Steve Wolfe | shot#8: No pcs changes; plasma, full length RF doing better. next shot: RF will start to square up the rf pulse. |
| Mar 24 2004 11:09:19:377AM | 1040324009 | Steve Wolfe | shot#9: No pcs changes; RF will start to square up the rf pulse. plasma full length, still not steady, hmode starts at .7, H-L at 1.14 next shot: raise field back to 5.6 |
| Mar 24 2004 11:20:16:113AM | 1040324010 | Steve Wolfe | shot#10: raise field back to 5.6 (tfcur to -154000) No plasma - breakers pulled out in pulse. |
| Mar 24 2004 11:44:20:400AM | 1040324011 | Steve Wolfe | shot#11: raise field back to 5.6 (tfcur to -154000) plasma full length, 3 or 4 H-modes, no ITB. |
| Mar 24 2004 11:58:16:157AM | 1040324012 | Steve Wolfe | shot#12: RF squaring up plasma full length, 3 or 4 H-modes, no ITB. |
| Mar 24 2004 12:09:15:727PM | 1040324013 | Steve Wolfe | shot#13: No power shot - got an I2t fault in init. |
| Mar 24 2004 12:29:05:240PM | 1040324014 | Steve Wolfe | shot#14: No changes plasma full length, nice steady eda Maybe an ITB starting at 1.15sec. next shot: Martin is thinking about it |
| Mar 24 2004 12:44:30:920PM | 1040324015 | Steve Wolfe | shot#15: raise power by .25MW plasma full length; couple of late trips ITB does start earlier back transition at 1.17 next shot: start on part2, with ramps starting at 1sec |
| Mar 24 2004 12:57:46:363PM | 1040324016 | Steve Wolfe | shot#16: start on part2, with ramps starting at 1sec plasma full length. Nice long eda, falling density during the on-axis ramp but no ITB formation before the ramps. next shot: weaker ramps |
| Mar 24 2004 01:11:26:430PM | 1040324017 | Steve Wolfe | shot#17: weaker ramps plasma full length, J has dropout at 1.2sec, drops out of H-mode. No sign of an ITB. next shot: delay ramps |
| Mar 24 2004 01:26:46:347PM | 1040324018 | Steve Wolfe | shot#18: delay ramps; raise Ip at .1sec to .65 and move next point to .120,-.8e6 (glitch was back on 17) plasma full length, glitch is gone again. No ITB evident. next shot: Try to get J back to 2.5MW |
| Mar 24 2004 01:41:56:713PM | 1040324019 | Steve Wolfe | shot#19: Try to get J back to 2.5MW plasma full length multiple H-modes. Lots of rf faulting early next shot: try again |
| Mar 24 2004 02:03:52:060PM | 1040324020 | Steve Wolfe | shot#20: try again plasma full length, rf fault late, one early fault. long eda but no ITB. next shot: nl04 to .95e20 |
| Mar 24 2004 02:21:49:697PM | 1040324021 | Steve Wolfe | shot#21: nl04 to .95e20 plasma disrupts at .890; sparks from J The 0.1sec glitch is back again too. next shot: no changes |
| Mar 24 2004 02:36:39:733PM | 1040324022 | Steve Wolfe | shot#22: no changes plasma full length, one early rf glitch , no ITB. Still have the .1sec glitch next shot: start rf at 0.5sec |
| Mar 24 2004 02:44:01:353PM | 1040324023 | Steve Wolfe | shot#23: start rf at 0.5sec still no itb forming next shot: go to 4.5T |
| Mar 24 2004 03:05:07:590PM | 1040324024 | Steve Wolfe | shot#24: go to 4.5T (-122000 tfcur), D+E only plasma full length, some rf trips at 1sec, looks like an itb starts at .8 and again at 1.3 next shot: start with the ramps again |
| Mar 24 2004 03:22:19:070PM | 1040324025 | Steve Wolfe | shot#25: start with the ramps again Still getting two h-modes, second has no ITB this time first radiates away |
| Mar 24 2004 03:37:59:783PM | 1040324026 | Steve Wolfe | shot#26: increase ramp rates. plasma full length still 2 hmodes First H-L is a little later. No ITB in second next shot: ramp harder |
| Mar 24 2004 03:52:40:977PM | 1040324027 | Steve Wolfe | shot#27: increase ramp rates. plasma full length H-L at 0.8 looks like several short itb phases. The .1sec injection is back. |
| Mar 24 2004 04:06:01:060PM | 1040324028 | Steve Wolfe | shot#28: accidentally did a pcs load. No changes. RF will ramp harder. plasma full length - looks very similar. next shot: start J .1sec earlier |
| Mar 24 2004 04:19:59:067PM | 1040324029 | Steve Wolfe | shot#29: start J .1sec earlier Or Not. plasma looks similar (not too surprising.) |
| Mar 24 2004 05:05:46:027PM | 1040324030 | Steve Wolfe | shot#30: start J .1sec earlier plasma - data system is frozen. Josh is storing data manually Looks like a late ITB, after 1sec on ECE? No nl04 signal. Mo rf signals. next shot: repeat |
| Mar 24 2004 05:37:12:213PM | 1040324031 | Steve Wolfe | shot#31: repeat plasma full length, back transition at .82 No itb. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:01:12:383AM | Plasma | Ok | |
| 2 | 09:17:46:347AM | Plasma | Ok | |
| 3 | 09:36:12:063AM | Plasma | Ok | |
| 4 | 09:49:56:973AM | Plasma | Ok | |
| 5 | 10:02:59:570AM | Plasma | Ok | |
| 6 | 10:19:34:050AM | Plasma | Ok | |
| 7 | 10:34:16:200AM | Plasma | Ok | |
| 8 | 10:48:58:080AM | Plasma | Ok | |
| 9 | 11:03:07:087AM | Plasma | Ok | |
| 10 | 11:17:10:373AM | Plasma | Bad | All TF and PF breakers opened at pulse again |
| 11 | 11:38:04:593AM | Plasma | Ok | |
| 12 | 11:54:13:680AM | Plasma | Ok | |
| 13 | 12:08:02:973PM | Plasma | Bad | I2T fault |
| 14 | 12:20:55:573PM | Plasma | Ok | |
| 15 | 12:35:45:157PM | Plasma | Ok | |
| 16 | 12:50:44:353PM | Plasma | Ok | |
| 17 | 01:07:02:207PM | Plasma | Ok | |
| 18 | 01:21:05:807PM | Plasma | Ok | |
| 19 | 01:37:04:063PM | Plasma | Ok | |
| 20 | 01:56:30:080PM | Plasma | Ok | |
| 21 | 02:11:04:743PM | Plasma | Ok | |
| 22 | 02:25:04:433PM | Plasma | Ok | |
| 23 | 02:38:35:300PM | Plasma | Ok | |
| 24 | 02:58:55:283PM | Plasma | Ok | |
| 25 | 03:16:21:903PM | Plasma | Ok | |
| 26 | 03:30:46:957PM | Plasma | Ok | |
| 27 | 03:45:36:637PM | Plasma | Ok | |
| 28 | 03:59:29:893PM | Plasma | Ok | |
| 29 | 04:13:42:697PM | Plasma | Ok | |
| 30 | 04:36:33:530PM | Plasma | Ok | |
| 31 | 05:07:42:653PM | Plasma | Ok | |
| 32 | 05:26:46:450PM | Test | Bad | pcdaqldx problems |
| 33 | 06:08:20:823PM | Test | Ok | |
| 34 | 06:57:32:243PM | Test | Ok | |