Alcator C-Mod Run 1040407 Information

Back to runs

Miniproposals
Miniproposal:203
Date Filed: 2/20/1998
Title:8 T H-mode Discharge Development with 3He Minority Heating
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-19)

Operators
Session leader(s):Steve Wukitch
Physics operator(s):Jim Irby
Engineering operator(s):Ed Fitzgerald

Engineering Operator Run Comment
MP#203 8T He3 Heating SL: Wukitch PO: Irby EO: Fitzgerald,Dekow,Parkin

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:04:257PM
Author: Steve Wukitch
Engineering setup for Wednesday, 07 Apr 2004

MP#203: 8T He3 Heating

Session leader: Wukitch
Physics operator: Irby

Overnight ECDC in D2 at 2e-4 Torr

Run begins at 09:00 and ends at 17:00.

Power systems the same as 1040331001 (1.05 MA, 5.5 T, lower X-point)

Once instrumentation has been checked we will load shot
1040331010 for 8T operation.

A-coils should be configured as on 1040127010 (+Dtop -Dbot -Jtop +Jbot)

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper with 15 psi He3 Hybrid enabled (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Disable NINJA

Enable the following gatevalves: ECE, VUV, DNB

Necessary diagnostics:
ECE (set for 8 tesla), TCI, halo current diagnostics, TF scanner and OH coax
resistance and thermocouple instrumentation

-------------------------------------------------------------------------------
RF Setup: All four transmitters in RUN-ON by 08:00, all at 80 MHz
-------------------------------------------------------------------------------
002 5.5 T Ip~1 MA, nl_04~0.85
D: 1 MW [0.6,1.3]sec
E: 1. MW [0.6,1.3]sec
J: 2 MW [0.6,1.3]sec
result: plasma - phase +140
D: ran
E: ran 2 faults
J: ran 6 faults
next shot: 8 T, 1.2 MA
003 7.9 T Ip~1.0 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma - early disruption
D: ran
E: ran
J: ran 1 fault
next shot: reload 002
004 7.9 T Ip~1.0 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma - early disruption
D: ran 1 fault
E: ran
J: ran 5 faults
next shot: 7.9 T (reload 003)
005 NTP
006 7.9 T Ip~1.2 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran 7 faults
E: ran 2 faults
J: ran
next shot: drop plasma current to 1 MA
007 7.9 T Ip~1 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran
E: ran
J: ran
nice temp increase (2.7->6 keV)
008 7.9 T Ip~0.8 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 1 fault
009 7.9 T Ip~0.8 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 1 fault
next shot: current to 0.9 MA
010 7.9 T Ip~0.9 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma - first H-mode dithers
D: ran 4 faults
E: ran 1 fault
J: ran
next shot: lower density to 0.7
011 7.9 T Ip~0.9 MA, nl_04~0.7, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma increased dithering
D: ran
E: ran
J: ran 1 fault
next shot: raise density to 1
012 7.9 T Ip~0.9 MA, nl_04~0.7, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 7 faults
next shot: raise density to 1
013 7.9 T Ip~0.9 MA, nl_04~1, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 7 faults
next shot: raise current to 1 MA
014 early disruption
015 7.9 T Ip~0.9 MA, nl_04~1, NO He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran max faults
next shot: He3 puff to 10 msec
016 7.9 T Ip~1 MA, nl_04~1, 10 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran max faults
next shot: He3 puff to 20 msec, Ip~1.2 MA
017 7.9 T Ip~1.2 MA, nl_04~1, 20 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma - early disruption
D: ran 6 faults
E: ran 1 faults
J: ran 1 faults
next shot: He3 puff to 30 msec
018 NTP
019 7.9 T Ip~1.2 MA, nl_04~1, 30 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma -dithers
D: ran 6 faults
E: ran
J: ran

Run Summary

This experiment is rather difficult to excute given the limits of the
RF reliablity, shot cycle, and available diagnostics. To add another
degree of difficulty, the He3 appears to accumulate from shot to shot
making reproducibility somewhat difficult. Reasonable heating efficiency
was observed at 8 T (see 007) and a few dithering discharges (see 019)
were obtained. The threshold appears to be around 4 T which is higher
than last summer. From the RF operation point of view, too little He3
appears to result in faulting in D and E antennas. We should finish
the He3 scan to find the gas puff at which significant mode conversion
is observed.

Physics Operator Summaries
Entered: Jul 7 2004 04:36:49:803PM
Author: Jim Irby
Physop Summary for MP#203: 8T He3 Heating

PO: Byford, Dekow, Parkin
Session leader: Wukitch
Physics operator: Irby


Summary
-------------------------------

The machine ran very well today at 8T and up to 1.2 MA.
We began the run with a 50 kA TF test shot. Several gate drive boards
had been replaced before the run in the TF supply. Checks were also
made of the fast and slow TF ground fault circuits. Shot 002 was a
5.4 T shot to compare with shot 1040331001 (the last He3 rf heating
run). On shot 007 we finally made it into rampdown at 7.8T, without
any breakers pulling, after a reduction in Ip from 1.2 to 1 MA. On
shot 008 both CLEARIN and RCUR were adjusted to rampdown at 1.2 rather
than 1.5 s. These changes produced a full length plasma that ramped
down all the way. By the end of the run, we had worked our way back up
to 1.2 MA with good rampdowns.

We also found that an increase in the early Ip programming demand and
a reduction in the early CLEARIN reduced the demand on the EFC and
eliminated the early disruptions (see shots 012, 013, and 014).

Shot 002 was very impressive with 7e13 neuts/s and Te above 6.3 kV.


Problems
-------------------------------

Bill Cochran and Gary Dekow debugged the TF supply before today's run.
They found 4 bad gate boards, plus one board with a bad connection.
In addition, yesterday they found that the conduction fault boards
were triggered even at low TF current.


Score
-------------------------------

duds

fizzles: 05,18

plasmas: 02,03,04,06,07,08,09,10,11,12,
13,14,15,16,17,19

tests: 01


Engineering setup for Wednesday, 07 Apr 2004
--------------------------------------------

MP#203: 8T He3 Heating

Session leader: Wukitch
Physics operator: Irby

Overnight ECDC in D2 at 2e-4 Torr

Run begins at 09:00 and ends at 17:00.

Power systems the same as 1040331001 (1.05 MA, 5.5 T, lower X-point)

Once instrumentation has been checked we will load shot 1040331010 for
8T operation.

A-coils should be configured as on 1040127010 (+Dtop -Dbot -Jtop +Jbot)

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper with 15 psi He3 Hybrid enabled (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Disable NINJA

Enable the following gatevalves: ECE, VUV, DNB

Necessary diagnostics:
ECE (set for 8 tesla), TCI, halo current diagnostics, TF scanner and OH coax
resistance and thermocouple instrumentation

-------------------------------------------------------------------------------
RF Setup: All four transmitters in RUN-ON by 08:00, all at 80 MHz
-------------------------------------------------------------------------------

Session Leader Comments
Apr 7 2004 09:49:08:933AM1040407002Steve Wukitch002 5.5 T Ip~1 MA, nl_04~0.85
D: 1 MW [0.6,1.3]sec
E: 1. MW [0.6,1.3]sec
J: 2 MW [0.6,1.3]sec
result: plasma - phase +140
D: ran
E: ran 2 faults
J: ran 6 faults
next shot: 8 T, 1.2 MA
Apr 7 2004 10:54:32:460AM1040407003Steve Wukitch003 5.5 T Ip~1.0 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma - early disruption
D: ran 1 fault
E: ran
J: ran 5 faults
next shot: reload 002
Apr 7 2004 11:07:31:653AM1040407004Steve Wukitch004 5.5 T Ip~1 MA, nl_04~0.85
D: 1 MW [0.6,1.3]sec
E: 1. MW [0.6,1.3]sec
J: 2 MW [0.6,1.3]sec
result: plasma
D: ran 1 fault
E: ran
J: ran 5 faults
next shot: 7.9 T (reload 003)
Apr 7 2004 11:10:15:733AM1040407005Steve Wukitch005 NTP
Apr 7 2004 11:56:39:953AM1040407006Steve Wukitch006 7.9 T Ip~1.2 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran 7 faults
E: ran 2 faults
J: ran
next shot: drop plasma current to 1 MA
Apr 7 2004 12:13:05:613PM1040407007Steve Wukitch007 7.9 T Ip~1 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma - no H-mode
D: ran
E: ran
J: ran
next shot: lower current to 0.8 MA
Apr 7 2004 12:53:06:570PM1040407008Steve Wukitch008 7.9 T Ip~0.8 MA, nl_04~0.85, 18 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 1 fault
Apr 7 2004 12:46:45:863PM1040407009Steve Wukitch009 7.9 T Ip~0.8 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 1 fault
next shot: current to 0.9 MA
Apr 7 2004 01:17:11:373PM1040407010Steve Wukitch010 7.9 T Ip~0.9 MA, nl_04~0.85, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2 MW ramp [0.6,1.15]sec
result: plasma - first H-mode dithers
D: ran 4 faults
E: ran 1 fault
J: ran
next shot: lower density to 0.7
Apr 7 2004 01:59:58:767PM1040407011Steve Wukitch011 7.9 T Ip~0.9 MA, nl_04~0.7, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma increased dithering
D: ran
E: ran
J: ran 1 fault
next shot: raise density to 1
Apr 7 2004 02:24:01:603PM1040407012Steve Wukitch012 7.9 T Ip~0.9 MA, nl_04~1, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 7 faults
next shot: repeat
Apr 7 2004 02:24:32:230PM1040407013Steve Wukitch013 7.9 T Ip~0.9 MA, nl_04~1, 15 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran 7 faults
next shot: raise current to 1 MA
Apr 7 2004 02:43:47:737PM1040407014Steve Wukitch014 early disruption
Apr 7 2004 03:36:05:800PM1040407015Steve Wukitch015 7.9 T Ip~1 MA, nl_04~1, NO He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran max faults
next shot: He3 puff to 10 msec
Apr 7 2004 03:55:46:187PM1040407016Steve Wukitch016 7.9 T Ip~1 MA, nl_04~1, 10 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma
D: ran max faults
E: ran max faults
J: ran max faults
next shot: He3 puff to 20 msec, Ip~1.2 MA
Apr 7 2004 04:14:16:747PM1040407017Steve Wukitch017 7.9 T Ip~1.2 MA, nl_04~1, 20 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma - early disruption
D: ran 6 faults
E: ran 1 faults
J: ran 1 faults
next shot: He3 puff to 30 msec
Apr 7 2004 04:34:22:013PM1040407018Steve Wukitch018 NTP
Apr 7 2004 05:01:20:240PM1040407019Steve Wukitch019 7.9 T Ip~1.2 MA, nl_04~1, 30 msec He3 puff
D: 1 MW ramp [0.6,1.15]sec
E: 1 MW ramp [0.6,1.15]sec
J: 2.2 MW ramp [0.6,1.15]sec
result: plasma -dithers
D: ran 6 faults
E: ran
J: ran

Physics Operator Comments
Apr 7 2004 07:53:34:267AMJim IrbyEngineering setup for Wednesday, 07 Apr 2004

MP#203: 8T He3 Heating

Session leader: Wukitch
Physics operator: Irby

Overnight ECDC in D2 at 2e-4 Torr

Run begins at 09:00 and ends at 17:00.

Power systems the same as 1040331001 (1.05 MA, 5.5 T, lower X-point)

Once instrumentation has been checked we will go load shot 1040331010 for 8T operation.

A-coils should be configured as on 1040127010 (+Dtop -Dbot -Jtop +Jbot)

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper with 15 psi He3 Hybrid enabled (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)

Disable NINJA

Enable the following gatevalves: ECE, VUV, DNB

Necessary diagnostics:
ECE (set for 8 tesla), TCI, halo current diagnostics, TF scanner and OH coax
resistance and thermocouple instrumentation

-------------------------------------------------------------------------------
RF Setup: All four transmitters in RUN-ON by 08:00, all at 80 MHz
-------------------------------------------------------------------------------
Apr 7 2004 08:13:35:493AMJim IrbyBill Cochran and Gary Dekow debugged the TF supply before today's run.
They found 4 bad gate boards, plus one board with a bad connection.
In addition, yesterday they found that the conduction fault boards
were triggered even at low TF current. They did not stop the run
yesterday only because these boards generate faults only above 200 kA.
Apr 7 2004 09:43:14:870AM1040407001Jim IrbyLoaded seg 2 from 1040331001 into seg 2.
Adjusted Bt in seg 1 to be 150 kA to match seg 2 Bt (5.407 T).
Will start out with seg 1 from yesterday, 1040406032

first shot will be 50 kA TF test --- lots of work in TF cabinets this morning

turn 79 lower at 2.66 uohm from CAMAC test data
turn 41 lower at 2.33 uohm
turn 42 lower at 2.35 uohm

scanner data okay

IGOR hang ---- Josh working on it

Apr 7 2004 09:57:14:220AM1040407002Jim Irby5.4 T, 1.0 MA attempt

plasma --- 170 kJ with 4.5 MW --- extended eda

oh okay

scanner 41 and 42 lower a little high at 5 and 5.1 uohm



Apr 7 2004 10:39:13:690AM1040407003Jim IrbyLoaded shot 1040331010 --- 8T, 1MA

Added 1 ms to prepuff

******* ESTOP was pressed in error ********

still had plasma out to .79 s


tf scanner looks great ---- core warmed a bit by crowbar

oh coax good

alternator 20 Hz natural mode oscillation very clear on RPM trace
Apr 7 2004 11:02:37:590AM1040407004Jim IrbyReloaded shot 2 for a TF test at 5.4 T --- all fuses checked again

added 1 ms to the prepuff

40 minute wait since shot 003

good shot

turns 41 and 42 lower back up some, but okay

oh coax okay, but oh2u up some from last shot

Zeff is up from shot 002 and plasma performance is not as good --- early injections
Apr 7 2004 11:23:58:970AM1040407005Jim IrbyBack to 8T but at 1.2 MA

No plasma!

Fields?
Apr 7 2004 11:56:30:157AM1040407006Jim IrbyEF4 from -1335 to -1325 A
Added 0.0005 T to Br0

disruption at 1.2 s

oh coax okay

tf scanner okay

injection did us in starting at 1.15 or so

Apr 7 2004 12:18:44:477PM1040407007Jim IrbyIp down to 1.0 MA

plasma into rampdown --- at last

nice hot plasma, but l-mode

TF scanner okay

Oh coax okay

alt okay

Apr 7 2004 12:33:44:420PM1040407008Jim IrbyArgon to 40 ms
Helium to 18 ms
Ip down to 800 kA --- see if h-modes return

started rcur and clearin rampdowns at 1.2 s rather than 1.5 s

tf scanner okay --- highest 41 and 42 lower

oh coax okay

d and e-port antennas had a little trouble

Apr 7 2004 12:57:19:040PM1040407009Jim IrbyNo changes except for rf tuning tweaks

rampdown not as good as 008

oh okay
tf scanner okay
alt okay
Apr 7 2004 01:21:46:563PM1040407010Jim IrbyIp to 900 kA
He3 gas puff 15 ms

plasma into rampdown

oh coax okay
tf scanner okay
Apr 7 2004 01:38:45:273PM1040407011Jim Irbynl04 request to 7.0e19/m^2

plasma into rampdown

better rf, some dithering?

oh okay

tf scanner okay

Apr 7 2004 02:07:37:973PM1040407012Jim Irbynl04 request to 1.0e20 /m^2

plasma into rampdown

got higher density

oh coax a little higher but okay

tf scanner okay

rf unhappy

Apr 7 2004 02:28:01:357PM1040407013Jim IrbyRepeat with better rf tune

plasma into rampdown

oh coax okay

tf scanner okay
Apr 7 2004 03:23:24:017PM1040407014Jim IrbyIp to 1 MA

plasma for 300 ms

Earl noticed big drop in EFC current that caused/contributed to disruption

oh coax okay
tf scanner okay

Apr 7 2004 03:35:08:843PM1040407015Jim IrbyTurned off He3 puff --- He level building up

Increased current rise before 0.177 s

took us 37 minutes to decide what to do about the current rise

plasma into rampdown

still have problem with efc --- almost lost plasma around 200 ms --- large rise in CII
Apr 7 2004 03:55:07:360PM1040407016Jim IrbyHe3 puff back on at 0.3 s for 10 ms

slowed down clearin rise around 0.2 s --- may help EFC problem

plasma into rampdown

EFC looks much better --- but we still have large CII signal around 0.2 s


Apr 7 2004 04:22:13:073PM1040407017Jim IrbyHe3 puff to 20 ms
Ip to 1.2 MA --- tried to keep rise the same from 200 to 300 ms

Dropped clearin another 1/2 mm or so.

disruption at 0.9 s

oh coax okay
tf scanner okay

Apr 7 2004 04:45:39:670PM1040407018Jim IrbyHe3 to 30 ms puff

fizzle --- Bz0 may have drifted down again

oh coax okay
tf scanner okay

Apr 7 2004 05:17:20:627PM1040407019Jim IrbyEF4 from -1325 to -1315 A

plasma into rampdown

heating looking better


oh coax okay
tf scanner okay

Engineering Operator Comments
ShotTimeTypeStatusComment
109:25:33:490AMTestOk50KA PLC Test Shot
209:41:33:807AMPlasmaOk
310:07:11:100AMPlasmaBadE-Stop Activated
410:50:10:817AMPlasmaOk
511:06:30:730AMPlasmaOk
611:29:29:927AMPlasmaBadEF1L Self Powered CKT fIRED
711:57:57:877AMPlasmaOk
812:20:32:480PMPlasmaOk
912:43:42:643PMPlasmaOk
1001:06:47:653PMPlasmaOk
1101:30:34:567PMPlasmaOk
1201:54:18:107PMPlasmaOk
1302:17:28:163PMPlasmaOk
1402:40:32:313PMPlasmaOk
1503:21:24:593PMPlasmaOk
1603:45:47:970PMPlasmaOk
1704:09:20:803PMPlasmaOk
1804:31:53:917PMPlasmaOk
1904:54:44:497PMPlasmaOk