| Miniproposals | ||||||||||
| ||||||||||
|
| Operators | |
| Session leader(s): | T.C. Hender,Vincent Tang |
| Physics operator(s): | Robert Granetz |
| Engineering operator(s): | Unknown |
| Engineering Operator Run Comment |
| MP#371 or MP#389 or MP#386/Granetz//Hender/Wolfe |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:05:257PM |
| Author: T.C. Hender |
| Run 1040429 (AM) MP361 SLs Hender and Wolfe PO Granetz The aim of the session was to complete the JET/C-Mod error field identity experiments by getting LM thresholds at both (i) high density and (ii) low density. In the event, due to the difficulties of operating at high density only the first aim was (partially) achieved. The session established (when combined with previous data) that in this JET configuration at 1.27MA the detachment density limit is nl04~2.5e20. It has been possible to operate well above this density (cf shot 1040408026) but only with a continuous MARFE (which is probably not desirable). The disruptions caused by the attempted high density operation led to a ~50% fizzle rate. Shot 11 gave very useful data with no LM and an A-coil current of 2.3kA at nl04~2.3e20. Likewise a locked mode was obtained close to full A-coil current in shot 16 at nl04~2.1e20. Finally there is a possible locked mode at full A-coil current in shot 13, which needs further analysis. Overall this is probably as far as we can go in getting high density data with large A-coil currents (and thus relatively smaller contributions from the intrinsic field errors). |
| Entered: Jul 7 2004 03:49:05:443PM |
| Author: Vincent Tang |
| Run Summary: This run was a continuation of 1040415; the idea was to run limited plasmas to prevent H-modes so we could finish the RF/density scan for MP 389. We had a lot of problems this afternoon; out of 15 shots, only 5 shots had plasma with DNB. Of those 5 shots, only 3 had new data; 1 shot was a repeat of 1040415006, and the other was not useful because of electronic problems. Initially, we wanted to do a RF scan at ne_l04~3e19 from 1MW to 3.5MW; however, we had to raise the density to ne_l~5e19 to prevent hard x-rays, fizzles, and disruptions. We got a power scan at ne_l~5e19 from 1.6-2.7MW; however, only the 1.6MW shot had noticeable DNB induced signal. The lower signals for the higher power shots could be because of the significantly lowered CX cross section for higher energy neutrals. In addition, compared with 1040415, the DNB pulses were weak today. More analysis is needed. The background signal during RF was significant. From what we can infer, a large portion of this background could be neutral particles, and potentially useful for determining the minority tail temperature. With the new 1.5s DNB, the rest of the RF and density scan in MP 389 could be easily accomplished. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:50:147PM |
| Author: Robert Granetz |
| Physics operator summary for run 1040429 (Thursday): MP 361 (con't): JET/C-Mod locked mode identity and MP 389 (con't): Compact Neutral Particle Analyzer (CNPA) testing Session leaders: Hender/Wolfe and V. Tang Physics operator: R. Granetz Summary: MP 361 -- The machine didn't want to run at the high densities required for this miniproposal. Every plasma disrupted, with very large halo currents (250-300 kA) because of the JET shape (outer strike point above divertor nose). There were also many fizzles, since the base pressure remained very high due to the disruptions. Despite these difficulties, we were able to get a pair of data points at one of the desired parameter settings. See Steve and Tim's summary for more physics details. MP 389 -- The machine didn't want to run at the very low densities required for this miniproposal, so we ran at a slightly higher density of nl_04=0.5e20 m-2 (target). We also ran diverted during the early part of the discharge, and then transitioned to inner-wall limited in time for the RF and the DNB. Hard x-rays were a problem for much of the low density operation. See Vincent's summary for details of the CNPA measurements. WE DISCOVERD DURING TODAY'S OPERATION THAT THE J-BOTTOM PIEZE VALVE HAS A SMALL LEAK. Scorecard: 20 plasmas 9 fizzles 1 dud (PF supplies crowbarred) 1 tests or no-power shot cycles 0 aborted and/or screwed up by computer problems 0 beam-into-gas calibration shots with B-field(s) ---------- 31 total ------------------------------------------------------------------------------- Engineering setup for Thursday, 29 Apr 2004 MP 361 (con't): JET/C-Mod locked mode identity and either MP 389 (con't): Compact Neutral Particle Analyzer (CNPA) testing or MP 386 (con't): Locked Mode threshold Note: The 2nd half of the run day will do MP 389 IF THE DNB IS OPERATIONAL, otherwise we will do MP 386. Session leaders: Hender/Wolfe and (V. Tang and/or Hutchinson/Wolfe) Physics operator: R. Granetz Overnight ECDC in D2, stopping two hours before the run. Run begins at 09:00 and ends at 17:00. Power systems as on 1040413029 Note: Acoil configuration (-Btop +Dbot +Gtop -Jbot) C-coil PLC limits set to 3 kA, 600 V. Start time set to 0.3 s, invert 2.0 s. (note change in start time) Gas Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 40 psi D2 Hybrid enabled (PG1)* leave B-side upper with 15 psi He3 Hybrid disabled fill C-side with 40 psi D2 Hybrid enabled (PG3) fill J-bot with 40 psi D2 Hybrid enabled (PG2)* * Note non-standard setup on B-side lower and J-bot. * * Note: no argon will be puffed today * Disable NINJA Enable the following gate valves, assuming no vacuum problems: ECE, VUV, DNB Necessary diagnostics: ECE set for 6.3 T; DNB (for MP 389) ------------------------------------------------------------------------------- RF Setup: None for MP 361; D & J or E & J (but not both D & E) for MP 389; None for MP 386; Have J and (D or E) in Run-on by 08:00, ready for the afternoon. ------------------------------------------------------------------------------- Run Plan for MP 361: q95=3.2 (I=1.3MA, B=6.3T, "JET shape") With ( -Btop+Dbot+Gtop-Jbot) trying to get LM data at high density: Note that we have non-standard gas setup, so for every reload of an old shot setup, we need to be careful that PG1 and PG2 programming is what we really want! Also, this equilibrium seems to be prone to making the TCI feedback fail, so we may want to run either nl_Zmeter or just pre-programmed gas puff if it isn't better than it was last time. 1. Repeat 1040413029 but with a target of nl04=3x10^20m-2 (compared to 2.1 x10^20 in reference shot). No A-coil current on this shot, in order to confirm no intrinsic locked mode forms. Use all available piezo valves to get density up as early as possible (including B-side lower - we don't need rotation data so we'll punt the usual Argon puff.) Note that PG2 should be reconnected to J-bot instead of B-side upper before the run (interface room change by Wolfe) 2. Repeat 1. With 2kA square in A-coil from 0.8s to 1.28s. And then vary A-coil current up and down to refine LM threshold. 3. If this going well (unlikely!) repeat 2. at nl04~4x10^20 m-2. Then with(Btop-Dbot-Gtop+Jbot) [just reverse the supply leads] trying to get LM data at low density: 4. Repeat 1040413013 (nl04~7e19) but with an Acoil=2kA square wave from 0.3 to 1.28s. Repeat with Acoil=2.5kA 5. Repeat 1040413010 (nl04~8.5e19) but with Acoil ramped linearly from 0A at 0.3s to 3.5kA at 1.28s (the aim of this shot is to always achieve sufficient intrinsic error field compensation to make no locked mode). Turn over to MP#389 or MP#386 at 13:00 or as soon thereafter as possible, so remote session leader can get his dinner. ----------------------- Run Plan for MP#389: This run requires the DNB to be operational. If it is not, then do MP#386. Start with 1040415006 (0.8 MA, 5.4 T, nl_04=0.3e20 m-2) except change it to be inner-wall limited. A-coil off. Prf = 1 MW from J-port. Fire the DNB during the RF. Increase Prf shot-to-shot in 0.5 MW steps, up to 3.5 MW. The power should come from D & J or E & J, BUT NOT BOTH D & E (to avoid the 0.5 MHz beat). If we complete this, we'll go to higher density. ----------------------- Run Plan for MP#386: These shots will be at 5.4T, 1MA. Since the GPC2 is going to still be set for high field, we'll be using the FRCECE for our core ECE signals. Change Acoil configuration to (-Dtop +Dbot +Jtop -Jbot), i.e. reversed from our "normal" connection. 1. Load 1040317025 and raise nl04 to 1.4e20 (remember to do the right thing with PG1 and PG2 (which is probably to have them disabled). Might also want to reduce the PG3 plenum pressure back to 30 psi. Set Acoil current to 1200A (program 1700A). This is point {3} on Ian's graph. 2. Raise or lower Acoil current setting to bracket threshold. 3. Load seg 2 from 1030715027 aiming for nl04~2.5e19, Acoil turned off. It will probably take a few shots to get the density down. The trick is going to be to prevent the shot from locking early; starting with a higher density and letting it drop seems better than having it low throughout (as we did on 1040414033). Also probably want to have significant pg3 puff in seg1. We expect a locked mode after .6sec with no A-coil current. 4a. If we don't get an intrinsic locked mode at step 3, turn on the A-coil (still in the "adverse" direction and raise the current until we do. Ideally we want to find the current that gives a locked mode at the time when oh1 is close to 18kA. 4b. If we did get an intrinsic locked mode in step 3, reverse the A-coil connection (just reverse the supply leads) to (+Dtop -Dbot -Jtop +Jbot). Set A-coil current to 1000A (program 1500A). This is Ian's point {1}. We expect this to lock. If it doesn't, decrease the Acoil current until it does; if it does lock, increase acoil current to 2000A, which should be unlocked (confirming the open green point on the graph). 5. Raise A-coil current to 3500A (program 4000A). This is Ian's point {2}. This should again be locked. If it isn't, we're done; if it is, reduce current to refine the upper bound of the stable region. ------------------------------------------------------------------------------- ECDC in D2 was done last night. Hybrid coldstart done by the engineering group; no errors found Loaded PCS segments 2,3,4 from shot 1040413029; use segment 2 This segment has NL_ZMETER enabled at a value of 1.0 Set PG2 (J-bot today, D2) to 100 V from t=0.4 to 1.3 s Copied PG2 waveform to PG1 (B-side-lower, D2) disabled A-coils (but programmed for 2500 A, t=0.80-1.28 s) PCS segment 1 from shot 1040428001 Confirmed proper A-coil setup (-Btop +Dbot +Gtop -Jbot) ------------------------------------------------------------------------------- The start of the run is delayed while a leak check is done. A small leak has been found on a mini-conflat on K-horizontal. It couldn't be bagged off due to its inaccessibility. Shot 01 -- Plasma. 1.25 MA, 6.3 T. Disrupted at t=0.61 s, as nl_04 was shooting up to reach 2.5e20 m-2. I_halo_L=280 kA!!! Got a halo current warning. Next shot: switch to TCI density feedback, programmed to 3.0e20 m-2. Also increase early PG3 programming in segment 2. Shot 02 -- Plasma. Another early disruption...multiple minor disruptions starting at t=0.24. It's not taking the early gas very well. Next shot: slow down the density rampup. Shot 03 -- Plasma. Disrupted at t=0.69 s, at Ip=1.3 MA. No moly injections. Density got to nl_04=2.7e20 m-2 before a series of disruptions begin. I_halo_L=260 kA...these shots have the outer strike point riding up to the nose of the outer divertor. Next shot: slow down the density rampup even more. Shot 04 -- Fizzle. Next shot: reduce pre-fill puff to 13 ms (from 15 ms) Shot 05 -- Plasma. Disrupted at t=0.80 s. I_halo_L=300 kA. Next shot: slow down density rise prior to t=0.4 s, and lower the ultimate density to nl_04=2.6e20 m-2 (from 3.0) Shot 06 -- Fizzle. Next shot: reduce pre-fill puff another 1 ms. Also enable density feedback control of PG2 (J-Bot), in addition to PG3. Shot 07 -- No-power shot cycle. EF3 breaker pulled out during check. Shot 08 -- Plasma. Disrupted at t=0.88 s. Density makes it slightly above the requested level. I_halo_L=240 kA. Next shot: reduce PG1 to 50 volts after t=0.7 s. Also reduce pre-fill another 1 ms (to 11 ms) Shot 09 -- Fizzle. Base pressure is very high, presumably because of all the disruptions. Next shot: reduce nl_04 to 2.1e20 m-2. Also reduce pre-fill puff to 9 ms. Shot 10 -- Fizzle. Very high base pressure. Next shot: reduce pre-fill another 2 ms (to 7 ms!) and add +10 A to IC_EF4. Shot 11 -- Plasma. Made it to t=1.28 s. I don't think there was any locked mode. I_halo_L=235 kA. Next shot: program A-coil current to 4 kA, same timing. Shot 12 -- Fizzle. These disruptions are killing us. Next shot: add -10 A to IC_EF4. Shot 13 -- Plasma. Disrupted at t=1.08 s, but it's not clear whether or not this was due to a locked mode. nl_04=2.35e20 m-2. Next shot: turn on A-coil 0.1 s earlier (at t=0.7 s), reduce nl_04 to 2.0e20 m-2 (from 2.1). Also some small Br0 and Bz0 tweaks. Shot 14 -- Fizzle. Next shot: undo the Br0 tweak Shot 15 -- Plasma. Disrupted very early. Looks like injections and/or dirt do it in starting around t=0.1 s. Next shot: try again, no changes Shot 16 -- Plasma. Disrupted at t=1.0 s. This time it looks like a locked mode induced by the high A-coil current (approx 3500 A). nl_04=2.1e20 m-2. End of MP 361 for today. Begin MP 389. Next shot: Load segment 2 from 1040415006 (.8 MA, 5.4 T, 0.3e20 m-2) Change to limited plasma (CLEARIN = -2 cm). Move RCUR in by 7.5 mm (to avoid hitting outer limiter). Re-patch A-coils to standard configuration. Set A-coil current to 2500 A. Disable B-side-lower and J-bottom gas valves. Shot 17 -- Fizzle. Base pressure was 1.4e-5 torr before the DNB gate valve opened. Next shot: reduce pre-fill puff to just 5 ms. Shot 18 -- Plasma. Good full-length shot. Ip=0.8 MA, Bt=5.5 T. nl_04=0.35e19 m-2. Prf=1.0 MW from J-antenna. Inner wall limited. Outer gap = 1.5 cm. Lots of moly at these low densities. There was a burst of runaways at the very end of the rampdown. Unfortunately, the DNB faulted. Next shot: repeat for the DNB. Also program in some more density late in the rampdown. Shot 19 -- Plasma. Beam fired. Prf=1 MW. nl_04=0.32e20 m-2 (target). Huge amount of hard x-rays. Next shot: more early gas puffing Note: since we're not using the B-side-lower and J-bottom gas valves, I just asked that they be pumped out (they're already disabled). This resulted in the base pressure dropping by more than an order of magnitude. THE J-BOTTOM PIEZO VALVE APPARENTLY LEAKS! I've also increased the pre-fill puff to 13 ms for the next shot. Shot 20 -- Plasma. Short, dirty, disruptive. Startup has changed, now that the base pressure is so much less. Next shot: increase pre-fill puff to 16 ms; add -10 A to IC_EF4; tweak early gas puffing some more. Shot 21 -- Plasma. Short, dirty, disruptive. Some hard x-rays, but much less than preceding shots. Next shot: try going the other way with IC_EF4. Add +20 amps. Shot 22 -- Fizzle. Next shot: change CLEARIN and RCUR so that the plasma is diverted until 0.7 s, then limited. Also tweak IC_EF4. Shot 23 -- Plasma. Disrupted at t=0.82 s, shortly after going back to inner wall limited. Still have some hard x-rays. Next shot: increase nl_04=0.5e20 m-2. Some more early gas and pre-fill puff tweaks. Shot 24 -- Plasma. Full-length shot. Prf=1.65 MW (J). Small amount of hard x-rays until late in the rampdown. nl_04 (target)=0.5e20 m-2. No H-mode (because the plasma becomes limited before the RF turns on). Next shot: more RF power; tweak pre-fill puff. Shot 25 -- Plasma. Full-length shot. Prf=2.1 MW (J). Lots of hard x-rays until t=1 s. nl_04 (target)=0.5e20 m-2, but density rises to 0.75e20 m-2 when the plasma becomes limited at t=0.7 s. No H-mode (because the plasma becomes limited before the RF turns on). Next shot: more RF power. Tweak early gas puffing. Shot 26 -- Plasma. Full-length shot. Prf=2.5 MW (E+J). Similar to previous shot. No DNB. Next shot: repeat for DNB. Shot 27 -- Plasma. Full-length shot. Prf=2.75 MW (E+J). Similar to previous shot. No DNB. Next shot: repeat for DNB. Shot 28 -- Fizzle. Next shot: tweak Br0. Shot 29 -- Plasma. Full-length shot. Prf=2.7 MW (E+J). Similar to earlier shots. Got the beam this time. Next shot: no PCS changes; same RF. Use larger aperture on the CNPA detector. Shot 30 -- Plasma. Full-length shot. Prf=2.6 MW (E+J). Similar to earlier shots. Got the beam. Most of the hard x-rays are gone, for no obvious reason. Next shot: no PCS changes; reduce Prf to 1 MW Shot 31 -- Dud. PF power supplies faulted before commutation. End of run |
| Session Leader Comments | |||
| Apr 28 2004 08:10:14:937AM | Steve Wolfe | On Wed at 8:00AM I tried out the gnomemeeting connection to JET with Hender. It works ok, provided I set the audio device to dsp0 (it was defaulting to dsp1). Reducing the microphone level helps reduce static on his end. I should try the echo cancellation/agc settings | |
| Apr 29 2004 07:12:56:017AM | Steve Wolfe | Run Plan for MP 361: q95=3.2 (I=1.3MA, B=6.3T, "JET shape") With ( -Btop+Dbot+Gtop-Jbot) trying to get LM data at high density: Note that we have non-standard gas setup, so for every reload of an old shot setup, we need to be careful that PG1 and PG2 programming is what we really want! Also, this equilibrium seems to be prone to making the TCI feedback fail, so we may want to run either nl_Zmeter or just pre-programmed gas puff if it isn't better than it was last time. 1. Repeat 1040413029 but with a target of nl04=3x10^20m-2 (compared to 2.1 x10^20 in reference shot). No A-coil current on this shot, in order to confirm no intrinsic locked mode forms. Use all available piezo valves to get density up as early as possible (including B-side lower - we don't need rotation data so we'll punt the usual Argon puff.) Note that PG2 should be reconnected to J-bot instead of B-side upper before the run (interface room change by Wolfe) 2. Repeat 1. With 2kA square in A-coil from 0.8s to 1.28s. And then vary A-coil current up and down to refine LM threshold. 3. If this going well (unlikely!) repeat 2. at nl04~4x10^20 m-2. Then with(Btop-Dbot-Gtop+Jbot) [just reverse the supply leads] trying to get LM data at low density: 4. Repeat 1040413013 (nl04~7e19) but with an Acoil=2kA square wave from 0.3 to 1.28s. Repeat with Acoil=2.5kA 5. Repeat 1040413010 (nl04~8.5e19) but with Acoil ramped linearly from 0A at 0.3s to 3.5kA at 1.28s (the aim of this shot is to always achieve sufficient intrinsic error field compensation to make no locked mode). Turn over to MP#389 or MP#386 at 13:00 or as soon thereafter as possible, so remote session leader can get his dinner. | |
| Apr 29 2004 09:23:00:950AM | Steve Wolfe | Yesterday's leak has been isolated to K-side, on a mini-conflat deep into the reentrant flange. It looks very hard to bag off. We will probably have to live with this high 8 scale leak for today, unless we're convinced it is hurting the breakdown. | |
| Apr 29 2004 09:44:30:867AM | 1040429001 | Steve Wolfe | Shot#1: Setup with B-side lower and J-bottom on pre-program and C-side on nl_zmeter, program feedback for 1V on NL_ZMETER. Disrupts at .6sec, possible locked mode at .6, but also an injection. Not sure which is first. |
| Apr 29 2004 10:03:24:823AM | 1040429002 | Steve Wolfe | Shot#2: Back to nl04 feedback. short disruption. next shot: slow down the density rise before crossover |
| Apr 29 2004 10:12:59:303AM | 1040429003 | Steve Wolfe | Shot#3: slow down the density rise before crossover another disruption at .69. density is rising fast. next shot: slow down density rise some more, aim for 3e20 at 1.0sec |
| Apr 29 2004 10:22:37:640AM | 1040429004 | Steve Wolfe | Shot#4: slow down density rise some more, aim for 3e20 at 1.0sec fizzle |
| Apr 29 2004 10:52:04:930AM | 1040429005 | Steve Wolfe | Shot#5: slow down density rise some more, aim for 3e20 at 1.0sec disrupts at .8sec |
| Apr 29 2004 10:53:03:007AM | 1040429006 | Steve Wolfe | Shot#6: slow down density rise some more, aim for 2.6e20 at 1.0sec fizzle |
| Apr 29 2004 11:12:10:527AM | 1040429007 | Steve Wolfe | Shot#7: slow down density rise some more, aim for 2.6e20 at 1.0sec No power shot. EF3 breaker opened in check. Also TCI CO2 signal went low. |
| Apr 29 2004 11:27:50:583AM | 1040429008 | Steve Wolfe | Shot#8: slow down density rise some more, aim for 2.6e20 at 1.0sec Disrupts at .9sec, still on rising density |
| Apr 29 2004 11:44:00:170AM | 1040429009 | Steve Wolfe | Shot#9: back off on b-side lower program puff fizzle |
| Apr 29 2004 11:48:01:927AM | 1040429010 | Steve Wolfe | Shot#10: punt the high density point. Go to 2.1e20 and turn on acoil, trying to make a locked mode at between 0.8 and 1.0sec fizzle |
| Apr 29 2004 12:06:14:120PM | 1040429011 | Steve Wolfe | Shot#11: try again for 2.1e20 and turn on acoil, trying to make a locked mode at between 0.8 and 1.0sec disrupts at 1.28sec no locked mode . |
| Apr 29 2004 12:15:36:240PM | 1040429012 | Steve Wolfe | Shot#12: Raise A-coil to 3500 (4000 demand) fizzle |
| Apr 29 2004 12:35:57:740PM | 1040429013 | Steve Wolfe | Shot#13: Raise A-coil to 3500 (4000 demand) plasma to 1.1sec Can't really see a locked mode. Drop the density a bit and turn acoil on earlier |
| Apr 29 2004 12:40:47:290PM | 1040429014 | Steve Wolfe | Shot#14: Drop the density a bit and turn acoil on earlier fizzle |
| Apr 29 2004 01:02:07:507PM | 1040429015 | Steve Wolfe | Shot#15: Drop the density to 2.1 and turn acoil on at .7sec, still 4000A demand Early disruption, turns around at .1sec ??? big injection at .095sec Try again |
| Apr 29 2004 01:15:48:790PM | 1040429016 | Steve Wolfe | Shot#16: Drop the density to 2.1 and turn acoil on at .7sec, still 4000A demand plasma disrupts at 1 sec locked mode at .9sec I think we got that point. Turn the run over to Vincent and resume tomorrow morning with the other acoil direction. |
| Apr 29 2004 01:33:35:183PM | 1040429016 | Vincent Tang | Continuting MP389. First shot a duplicate of 1040415006, except inner limited. Aperture set at 2.10/45. Attempt to reproduce 1040415006 CNPA signal. Main focus today is power scan at ne_l4=0.3 & up wihtout going into H-Mode |
| Apr 29 2004 01:43:20:473PM | 1040429017 | Vincent Tang | No plasma, but saw DNB induced signal on CNPA |
| Apr 29 2004 02:00:36:450PM | 1040429018 | Vincent Tang | Next shot: repeat; Beam didn't fire. Density a little high, but good flattop. Good shot. Got background neutral signal on CNPA |
| Apr 29 2004 02:14:01:183PM | 1040429019 | Vincent Tang | Stronger signal during DNB, but only about 20% more. The large HXR background is probably the cause. |
| Apr 29 2004 02:32:29:953PM | 1040429020 | Vincent Tang | We are moving to 1.5MW; even though we have not been able to completely reproduce the signal on 1040415006. |
| Apr 29 2004 02:46:39:907PM | 1040429021 | Vincent Tang | disrupted at 0.5; will have to repeat. In general, Zeff and soft & hard x-ray problems worse than 1040415. DNB current is also lower. We might have some difficutly with signal/background for the CNPA today. |
| Apr 29 2004 02:55:25:620PM | 1040429022 | Vincent Tang | shot 22: fizzle; next shot will start diverted. |
| Apr 29 2004 03:27:00:343PM | 1040429024 | Vincent Tang | Shot 24: Good shot, good signal during DNB. Energy spectrum is stronger and counts are greater. |
| Apr 29 2004 03:43:41:947PM | 1040429025 | Vincent Tang | Shot 25: DNB signal not significantly above background. Next shot: 2.5MW; We might try opening the aperture a bit wider. The density on this shot was also higher; The beam might have difficulty penetrating. |
| Apr 29 2004 03:51:15:773PM | 1040429026 | Vincent Tang | Next shot: repeat; DNB didn't fire. |
| Apr 29 2004 04:05:11:727PM | 1040429027 | Vincent Tang | Next shot: repeat; DNB didn't fire. |
| Apr 29 2004 04:13:22:800PM | 1040429028 | Vincent Tang | Next shot: repeat, DNB fired, but fizzle. |
| Apr 29 2004 04:36:28:077PM | 1040429029 | Vincent Tang | Next: repeat of 29, but with aperture opened to 3 |
| Apr 29 2004 05:25:35:797PM | 1040429029 | Vincent Tang | No significant DNB induced signal. Good background though. |
| Apr 29 2004 05:26:41:840PM | 1040429030 | Vincent Tang | Larger aperture(or other unknown cause) overflooded digitizer system; no usable signal at all. |
| Physics Operator Comments | |||
| Apr 29 2004 08:34:18:330AM | Robert Granetz | ECDC in D2 was done last night. Hybrid coldstart done by the engineering group; no errors found Loaded PCS segments 2,3,4 from shot 1040413029; use segment 2 This segment has NL_ZMETER enabled at a value of 1.0 Set PG2 (J-bot today, D2) to 100 V from t=0.4 to 1.3 s Copied PG2 waveform to PG1 (B-side-lower, D2) disabled A-coils (but programmed for 2500 A, t=0.80-1.28 s) PCS segment 1 from shot 1040428001 Confirmed proper A-coil setup (-Btop +Dbot +Gtop -Jbot) | |
| Apr 29 2004 09:28:10:327AM | Robert Granetz | The start of the run is delayed while a leak check is done. A small leak has been found on a mini-conflat on K-horizontal. It couldn't be bagged off due to its inaccessibility. | |
| Apr 29 2004 09:50:46:917AM | 1040429001 | Robert Granetz | Shot 01 -- Plasma. 1.25 MA, 6.3 T. Disrupted at t=0.61 s, as nl_04 was shooting up to reach 2.5e20 m-2. I_halo_L=280 kA!!! Got a halo current warning. Next shot: switch to TCI density feedback, programmed to 3.0e20 m-2. Also increase early PG3 programming in segment 2. |
| Apr 29 2004 10:02:43:903AM | 1040429002 | Robert Granetz | Shot 02 -- Plasma. Another early disruption...multiple minor disruptions starting at t=0.24. It's not taking the early gas very well. Next shot: slow down the density rampup. |
| Apr 29 2004 10:14:30:313AM | 1040429003 | Robert Granetz | Shot 03 -- Plasma. Disrupted at t=0.69 s, at Ip=1.3 MA. No moly injections. Density got to nl_04=2.7e20 m-2 before a series of disruptions begin. I_halo_L=260 kA...these shots have the outer strike point riding up to the nose of the outer divertor. Next shot: slow down the density rampup even more. |
| Apr 29 2004 10:24:15:933AM | 1040429004 | Robert Granetz | Shot 04 -- Fizzle. Next shot: reduce pre-fill puff to 13 ms (from 15 ms) |
| Apr 29 2004 10:53:04:943AM | 1040429005 | Robert Granetz | Shot 05 -- Plasma. Disrupted at t=0.80 s. I_halo_L=300 kA. Next shot: slow down density rise prior to t=0.4 s, and lower the ultimate density to nl_04=2.6e20 m-2 (from 3.0) |
| Apr 29 2004 10:57:11:950AM | 1040429006 | Robert Granetz | Shot 06 -- Fizzle. Next shot: reduce pre-fill puff another 1 ms. Also enable density feedback control of PG2 (J-Bot), in addition to PG3. |
| Apr 29 2004 11:16:23:250AM | 1040429007 | Robert Granetz | Shot 07 -- No-power shot cycle. EF3 breaker pulled out during check. |
| Apr 29 2004 11:41:01:960AM | 1040429008 | Robert Granetz | Shot 08 -- Plasma. Disrupted at t=0.88 s. Density makes it slightly above the requested level. I_halo_L=240 kA. Next shot: reduce PG1 to 50 volts after t=0.7 s. Also reduce pre-fill another 1 ms (to 11 ms) |
| Apr 29 2004 11:52:39:073AM | 1040429010 | Robert Granetz | Shot 10 -- Fizzle. Very high base pressure. Next shot: reduce pre-fill another 2 ms (to 7 ms!) and add +10 A to IC_EF4. |
| Apr 29 2004 12:07:23:163PM | 1040429011 | Robert Granetz | Shot 11 -- Plasma. Made it to t=1.28 s. I don't think there was any locked mode. I_halo_L=235 kA. Next shot: program A-coil current to 4 kA, same timing. |
| Apr 29 2004 12:18:54:450PM | 1040429012 | Robert Granetz | Shot 12 -- Fizzle. These disruptions are killing us. Next shot: add -10 A to IC_EF4. |
| Apr 29 2004 12:36:31:673PM | 1040429013 | Robert Granetz | Shot 13 -- Plasma. Disrupted at t=1.08 s, but it's not clear whether or not this was due to a locked mode. nl_04=2.35e20 m-2. Next shot: turn on A-coil 0.1 s earlier (at t=0.7 s), reduce nl_04 to 2.0e20 m-2 (from 2.1). Also some small Br0 and Bz0 tweaks. |
| Apr 29 2004 12:46:20:810PM | 1040429014 | Robert Granetz | Shot 14 -- Fizzle. Next shot: undo the Br0 tweak |
| Apr 29 2004 01:15:42:507PM | 1040429016 | Robert Granetz | Shot 16 -- Plasma. Disrupted at t=1.0 s. This time it looks like a locked mode induced by the high A-coil current (approx 3500 A). nl_04=2.1e20 m-2. |
| Apr 29 2004 01:26:28:683PM | 1040429016 | Robert Granetz | Next shot: Load segment 2 from 1040415006 (.8 MA, 5.4 T, 0.3e20 m-2) Change to limited plasma (CLEARIN = -2 cm). Move RCUR in by 7.5 mm (to avoid hitting outer limiter). Re-patch A-coils to standard configuration. Set A-coil current to 2500 A. Disable B-side-lower and J-bottom gas valves. |
| Apr 29 2004 05:06:51:427PM | 1040429016 | Robert Granetz | End of MP 361 for today. Begin MP 389 on the next shot |
| Apr 29 2004 01:44:05:160PM | 1040429017 | Robert Granetz | Shot 17 -- Fizzle. Base pressure was 1.4e-5 torr before the DNB gate valve opened. Next shot: reduce pre-fill puff to just 5 ms. |
| Apr 29 2004 02:03:21:193PM | 1040429018 | Robert Granetz | Shot 18 -- Plasma. Good full-length shot. Ip=0.8 MA, Bt=5.5 T. nl_04=0.35e19 m-2. Prf=1.0 MW from J-antenna. Inner wall limited. Outer gap = 1.5 cm. Lots of moly at these low densities. There was a burst of runaways at the very end of the rampdown. Unfortunately, the DNB faulted. Next shot: repeat for the DNB. Also program in some more density late in the rampdown. |
| Apr 29 2004 02:20:01:687PM | 1040429019 | Robert Granetz | Shot 19 -- Plasma. Beam fired. Prf=1 MW. nl_04=0.32e20 m-2 (target). Huge amount of hard x-rays. Next shot: more early gas puffing Note: since we're not using the B-side-lower and J-bottom gas valves, I just asked that they be pumped out (they're already disabled). This resulted in the base pressure dropping by more than an order of magnitude. THE J-BOTTOM PIEZO VALVE APPARENTLY LEAKS! I've also increased the pre-fill puff to 13 ms for the next shot. |
| Apr 29 2004 02:37:18:130PM | 1040429020 | Robert Granetz | Shot 20 -- Plasma. Short, dirty, disruptive. Startup has changed, now that the base pressure is so much less. Next shot: increase pre-fill puff to 16 ms; add -10 A to IC_EF4; tweak early gas puffing some more. |
| Apr 29 2004 02:49:49:447PM | 1040429021 | Robert Granetz | Shot 21 -- Plasma. Short, dirty, disruptive. Some hard x-rays, but much less than preceding shots. Next shot: try going the other way with IC_EF4. Add +20 amps. |
| Apr 29 2004 03:00:11:627PM | 1040429022 | Robert Granetz | Shot 22 -- Fizzle. Next shot: change CLEARIN and RCUR so that the plasma is diverted until 0.7 s, then limited. Also tweak IC_EF4. |
| Apr 29 2004 03:15:53:447PM | 1040429023 | Robert Granetz | Shot 23 -- Plasma. Disrupted at t=0.82 s, shortly after going back to inner wall limited. Still have some hard x-rays. Next shot: increase nl_04=0.5e20 m-2. Some more early gas and pre-fill puff tweaks. |
| Apr 29 2004 03:27:08:627PM | 1040429024 | Robert Granetz | Shot 24 -- Plasma. Full-length shot. Prf=1.65 MW (J). Small amount of hard x-rays until late in the rampdown. nl_04 (target)=0.5e20 m-2. No H-mode (because the plasma becomes limited before the RF turns on). Next shot: more RF power; tweak pre-fill puff. |
| Apr 29 2004 03:40:35:953PM | 1040429025 | Robert Granetz | Shot 25 -- Plasma. Full-length shot. Prf=2.1 MW (J). Lots of hard x-rays until t=1 s. nl_04 (target)=0.5e20 m-2, but density rises to 0.75e20 m-2 when the plasma becomes limited at t=0.7 s. No H-mode (because the plasma becomes limited before the RF turns on). Next shot: more RF power. Tweak early gas puffing. |
| Apr 29 2004 03:52:56:707PM | 1040429026 | Robert Granetz | Shot 26 -- Plasma. Full-length shot. Prf=2.5 MW (E+J). Similar to previous shot. No DNB. Next shot: repeat for DNB. |
| Apr 29 2004 04:00:24:377PM | 1040429027 | Robert Granetz | Shot 27 -- Plasma. Full-length shot. Prf=2.75 MW (E+J). Similar to previous shot. No DNB. Next shot: repeat for DNB. |
| Apr 29 2004 04:13:18:080PM | 1040429028 | Robert Granetz | Shot 28 -- Fizzle. Next shot: tweak Br0. |
| Apr 29 2004 04:31:34:947PM | 1040429029 | Robert Granetz | Shot 29 -- Plasma. Full-length shot. Prf=2.7 MW (E+J). Similar to earlier shots. Got the beam this time. Next shot: no PCS changes; same RF. Use larger aperture on the CNPA detector. |
| Apr 29 2004 04:53:19:910PM | 1040429030 | Robert Granetz | Shot 30 -- Plasma. Full-length shot. Prf=2.6 MW (E+J). Similar to earlier shots. Got the beam. Most of the hard x-rays are gone, for no obvious reason. Next shot: no PCS changes; reduce Prf to 1 MW |
| Apr 29 2004 05:03:46:560PM | 1040429031 | Robert Granetz | Shot 31 -- Dud. PF power supplies faulted before commutation. End of run |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:35:20:157AM | Plasma | Ok | |
| 2 | 09:52:39:613AM | Plasma | Ok | |
| 3 | 10:05:51:100AM | Plasma | Ok | |
| 4 | 10:20:53:613AM | Plasma | Ok | |
| 5 | 10:34:55:783AM | Plasma | Ok | |
| 6 | 10:49:47:703AM | Plasma | Ok | |
| 7 | 11:05:29:400AM | Plasma | Ok | |
| 8 | 11:17:03:107AM | Plasma | Ok | |
| 9 | 11:32:54:057AM | Plasma | Ok | |
| 10 | 11:45:57:073AM | Plasma | Ok | |
| 11 | 11:58:55:167AM | Plasma | Ok | |
| 12 | 12:12:15:903PM | Plasma | Ok | |
| 13 | 12:24:49:357PM | Plasma | Ok | |
| 14 | 12:39:02:373PM | Plasma | Ok | |
| 15 | 12:56:32:190PM | Plasma | Ok | |
| 16 | 01:09:17:617PM | Plasma | Ok | |
| 17 | 01:39:00:797PM | Plasma | Ok | |
| 18 | 01:51:41:580PM | Plasma | Ok | |
| 19 | 02:04:15:253PM | Plasma | Ok | |
| 20 | 02:26:53:187PM | Plasma | Ok | |
| 21 | 02:40:07:593PM | Plasma | Ok | |
| 22 | 02:52:43:063PM | Plasma | Ok | |
| 23 | 03:05:20:537PM | Plasma | Ok | |
| 24 | 03:18:03:770PM | Plasma | Ok | |
| 25 | 03:31:20:367PM | Plasma | Ok | |
| 26 | 03:43:47:900PM | Plasma | Ok | |
| 27 | 03:56:23:997PM | Plasma | Ok | |
| 28 | 04:09:30:933PM | Plasma | Ok | |
| 29 | 04:23:31:713PM | Plasma | Ok | |
| 30 | 04:46:41:287PM | Plasma | Ok | |
| 31 | 04:59:14:930PM | Plasma | Bad | OH2L comm fault at -0.7secs |