Alcator C-Mod Run 1040504 Information

Back to runs

Miniproposals
Miniproposal:390
Date Filed: 2/25/2004
Title:Evaluation of D(3He) minority heating
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-22)

Operators
Session leader(s):Steve Wukitch
Physics operator(s):Dmitri Mossessian
Engineering operator(s): Unknown

Engineering Operator Run Comment
MP#390 Evaluation of D(He3) minority heating; SL Wukitch; PO:Mossessian;

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:05:680PM
Author: Steve Wukitch
Session leader: S. Wukitch
Physics operator: D. Mossessian

MP#390 Evaluation of D(He3) minority heating

If available, ECDC Overnight in D2, stopping by 07:00
Run begins at 11:00 and ends at 17:00.

Power systems the same as 1040423002

A-coils as on 1040423002.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper with 15 psi He3 Hybrid enabled (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)


Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB

RF: Transmitters #1,2,3 and 4 in RUN-ON by 08:30
-----------------------------------------------------------------------------------
001-006 Beam into gas
007 Recall 1040423002 (Ip~1 MA, BT~5.4 T, nl04~0.8)
J: 1 MW [1.15,1.2] sec
result: plasma
J: max faults
next shot: retry with better match
008 Recall 1040423002 (Ip~1 MA, BT~5.4 T, nl04~0.8)
J: 1 MW [1.15,1.2] sec
result: plasma - lock mode
J: max faults
next: retry with better match
add A-coils to avoid lock mode
009 NTP
010 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.2] sec
result: plasma - response to J4 pulses in the sawteeth
J: J4 was improved/J3 max faults
next: improve J3 match
011 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.25] sec
result: plasma
J: max faults
next: put proper match in this time
012 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.25] sec
result: plasma - density feedback went wild
013 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.25] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
next: working on J3
014 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
next: working on J3
015 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
next: change J3 rate of power rise
016 Ip~1 MA, BT~5.1 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
017 Ip~1 MA, BT~5.1 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
018 NTP
019 Ip~1 MA, BT~5.1 T, nl04~0.8
J3: 0.5 MW [1.1,1.25] sec
J4: 1 MW [1.2,1.45] sec
result: plasma - H-mode
J3: max faults
J4: ran 2 faults
020 Ip~1 MA, BT~5.1 T, nl04~0.8
J3: 0.5 MW [1.1,1.25] sec
J4: 1.3 MW [1.2,1.45] sec
result: plasma - H-mode
J3: max faults
J4: ran 2 faults and quit why?
021 Ip~1 MA, BT~5.1 T, nl04~0.8
J3: 0.5 MW [1.1,1.25] sec
J4: 1.3 MW [1.2,1.45] sec
result: plasma - H-mode
J3: max faults
J4: ran 2 faults and quit why?
022 runaway density

Run Summary

The run focussed primarily upon coupling power into J-port at 50 MHz. The
initial vacuum tests were unsuccessful, but we decided to pursue plasma
discharges for completeness. With J4, we were able to couple up to ~1 MW
with few trips and struggled with ~1.25 MW. J3 operation was hampered by
breakdown at fairly low power and voltage (15 kV). On 021, a change in the
matching appeared to be more successful but 022 had runaway density. The
run confirms that previous operation was limited by an RF leakage problem
and a second problem likely to be breakdown at a high voltage location.
Discharge 021 suggests this problem may be in the matching network. Further
discharges are required to improve the match and verify J3 will operate.
The RF leakage appears to be less than last configuration but still have noise
on neutrons, hirex, and the ratiomatic. This suggests we need to further
increase the capacitance to reduce the RF leakage. In addition the loading
is significantly lighter than 78 or 79 MHz operation. J4 reached 34 kV for
1 MW injected compared to ~25 kV at 78 MHz.

Physics Operator Summaries
Entered: Jul 7 2004 04:36:50:190PM
Author: Dmitri Mossessian
Physop summary for Tuesday, May 4.

Run plan:

Session leader: S. Wukitch
Physics operator: D. Mossessian

MP#390 Evaluation of D(He3) minority heating

If available, ECDC Overnight in D2, stopping by 07:00
Run begins at 11:00 and ends at 17:00.

Power systems the same as 1040423002

A-coils as on 1040423002.

Gas setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper with 15 psi He3 Hybrid enabled (PG2)
fill C-side with 30 psi D2 Hybrid enabled (PG3)


Enable the following gate valves, assuming no vacuum problems:
ECE, VUV, DNB

RF: Transmitters #1,2,3 and 4 in RUN-ON by 08:30

_________________________________________________________

Summary:

The run was supposed to start at 11 am, but was delayed until noon.
Since RF still had problems at noon, we switched to MP #394 - MSE calibrations.
The calibrations are performed by firing DNB into the gas (no plasma) with only
TF, EF4 and EF3 suppplies running.
Aftr 5 calibration shots (2-6) we switched back to MP#390.
Plasma ran OK, with no startup problems. Few shots disrupted early because of large injections.
After getting a locked mode disruption on shot 8 it was realized that A-coil is not
configured properly and is disabled. A-coil was turned on from shot 9 on.
Overall we had 21 shots, 15 plasmas and 5 MSE calibration. First shot was a test.

Details:


----------------------------------------------------------------------------
1040504002 EF3 disabled, EF4 = 5 kA, PG4 - 800 msec
----------------------------------------------------------------------------
1040504003 EF3 disabled, EF4 = 5 kA, PG4 - 400 msec resulting in 1 mtor
----------------------------------------------------------------------------
1040504004 EF3 disabled, EF4 = 5 kA, PG4 - 200 msec resulting in 0.5 mtor
----------------------------------------------------------------------------
1040504006 EF3 disabled, EF4 = 5 kA, PG4 - 100 msec resulting in 0.25 mtor

Next shot - run plasma shot for RF. Load 1040423002. PG2 to 60 msec for He3
----------------------------------------------------------------------------
1040504008 Plasma. Locked mode - A coil is not set up right and is desabled.

Next shot - verify the present settings for A-coil and enable it.
----------------------------------------------------------------------------
1040504009 Plasma. Disrupted at 0.433 sec due to very large injection.

Next shot - repeat.
----------------------------------------------------------------------------
1040504010 Plasma. Ramps down to Ip=0 - A coil works (?)

Next shot - repeat.
----------------------------------------------------------------------------
1040504011 Plasma.

Next shot - repeat.
----------------------------------------------------------------------------
1040504015 Plasma.

Next shot - Bt down to 5.1 T (TF current -> 141600)
----------------------------------------------------------------------------
1040504007 Plasma. Good shot, but not too much RF.

Next shot - repeat
----------------------------------------------------------------------------
1040504012 Plasma. Disrupted - TCI broke, no feedback, density rose to 6e20 on TS.

Next shot - no change
----------------------------------------------------------------------------
1040504013 Plasma.

Next shot - no change
----------------------------------------------------------------------------
1040504014 Plasma.

Next shot - no change
----------------------------------------------------------------------------
1040504017 Plasma.

Next shot - no change.
----------------------------------------------------------------------------
1040504018 Plasma. Disrupted at 0.12 sec due to injection.

Next shot - no change.
----------------------------------------------------------------------------
1040504020 Plasma.

Next shot - no change.
----------------------------------------------------------------

1040504021 Plasma.


Session Leader Comments
May 4 2004 01:31:32:063PM1040504007Steve Wukitch007 Recall 1040423002 (Ip~1 MA, BT~5.4 T, nl04~0.8)
J: 1 MW [1.15,1.2] sec
result: plasma
J: max faults
next shot: retry with better match
May 4 2004 01:46:42:013PM1040504008Steve Wukitch008 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.1,1.25] sec
result: plasma - lock mode
J: max faults
next shot: retry with better match
add A-coils to avoid lock mode
May 4 2004 02:11:39:173PM1040504009Steve Wukitch009 NTP
May 4 2004 02:23:02:510PM1040504010Steve Wukitch010 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.2] sec
result: plasma - response to J4 pulses in the sawteeth
J: J4 was improved/J3 max faults
next: improve J3 match
May 4 2004 02:30:46:533PM1040504011Steve Wukitch011 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.1,1.25] sec
result: plasma
J: max faults
next: put proper match in this time
May 4 2004 02:51:15:220PM1040504012Steve Wukitch012 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.25] sec
result: plasma - density feedback went wild
May 4 2004 03:10:15:360PM1040504013Steve Wukitch013 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.25] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
next: working on J3
May 4 2004 03:21:18:163PM1040504014Steve Wukitch014 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
next: working on J3
May 4 2004 03:28:52:043PM1040504015Steve Wukitch015 Ip~1 MA, BT~5.4 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
next: change J3 rate of power rise
May 4 2004 04:20:02:443PM1040504016Steve Wukitch016 Ip~1 MA, BT~5.1 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
May 4 2004 04:20:16:430PM1040504017Steve Wukitch017 Ip~1 MA, BT~5.1 T, nl04~0.8
J: 1 MW [1.15,1.45] sec
result: plasma - H-mode
J: J4 clean/J3 max faults
May 4 2004 04:20:30:930PM1040504018Steve Wukitch018 NTP
May 4 2004 04:33:23:363PM1040504019Steve Wukitch019 Ip~1 MA, BT~5.1 T, nl04~0.8
J3: 0.5 MW [1.1,1.25] sec
J4: 1 MW [1.2,1.45] sec
result: plasma - H-mode
J3: max faults
J4: ran 2 faults
May 4 2004 04:49:10:443PM1040504020Steve Wukitch020 Ip~1 MA, BT~5.1 T, nl04~0.8
J3: 0.5 MW [1.1,1.25] sec
J4: 1.3 MW [1.2,1.45] sec
result: plasma - H-mode
J3: max faults
J4: ran 2 faults and quit why?
May 4 2004 05:17:16:877PM1040504021Steve Wukitch021 Ip~1 MA, BT~5.1 T, nl04~0.8
J3: 0.5 MW [1.1,1.25] sec
J4: 1.3 MW [1.2,1.45] sec
result: plasma - H-mode
J3: max faults
J4: ran max faults
May 4 2004 05:17:29:860PM1040504022Steve Wukitch022 runaway density

Physics Operator Comments
May 4 2004 10:29:09:347AMDmitri Mossessian10:27 AM Run delayed for another hour due to RF problems.

Tentative start time - 12:00.
May 4 2004 11:59:49:340AMDmitri MossessianDue to RF problems MP#390 is cancelled.

Instead, MSE calibrations MP#394 will be performed, requiring no plasma runs
with EF3, EF4 and TF supplies operating.

The waveforms for the supplies are programed in shot 1040422020.

Plan:

Load 1040422020. Change EF3, EF4 amplitudes and gas pressure (varying prepuff) as directed by MP#394.
May 4 2004 12:21:25:527PM1040504002Dmitri MossessianEF3 disabled, EF4 = 5 kA, PG4 - 800 msec
May 4 2004 12:34:28:177PM1040504003Dmitri MossessianEF3 disabled, EF4 = 5 kA, PG4 - 400 msec resulting in 1 mtor
May 4 2004 12:48:55:937PM1040504004Dmitri MossessianEF3 disabled, EF4 = 5 kA, PG4 - 200 msec resulting in 0.5 mtor
May 4 2004 01:16:12:303PM1040504006Dmitri Mossessian EF3 disabled, EF4 = 5 kA, PG4 - 100 msec resulting in 0.25 mtor

Next shot - run plasma shot for RF. Load 1040423002. PG2 to 60 msec for He3
May 4 2004 03:33:43:003PM1040504007Dmitri MossessianPlasma. Good shot, but not too much RF.

Next shot - repeat
May 4 2004 01:42:13:243PM1040504008Dmitri MossessianPlasma. Locked mode - A coil is not set up right and is desabled.

Next shot - verify the present settings for A-coil and enable it.
May 4 2004 02:06:27:000PM1040504009Dmitri MossessianPlasma. Disrupted at 0.433 sec due to very large injection.

Next shot - repeat.
May 4 2004 02:14:51:457PM1040504010Dmitri MossessianPlasma. Ramps down to Ip=0 - A coil works (?)

Next shot - repeat.
May 4 2004 02:28:18:110PM1040504011Dmitri MossessianPlasma.

Next shot - repeat.
May 4 2004 03:40:54:600PM1040504012Dmitri MossessianPlasma. Disrupted - TCI broke, no feedback, density rose to 6e20 on TS.

Next shot - no change
May 4 2004 03:41:26:350PM1040504013Dmitri MossessianPlasma.

Next shot - no change
May 4 2004 03:41:31:947PM1040504014Dmitri MossessianPlasma.

Next shot - no change
May 4 2004 03:25:44:463PM1040504015Dmitri MossessianPlasma.

Next shot - Bt down to 5.1 T (TF current -> 141600)
May 4 2004 04:01:31:023PM1040504017Dmitri MossessianPlasma.

Next shot - no change.
May 4 2004 04:21:01:007PM1040504018Dmitri MossessianPlasma. Disrupted at 0.12 sec due to injection.

Next shot - no change.
May 4 2004 04:43:40:777PM1040504020Dmitri MossessianPlasma.

Next shot - no change.
May 4 2004 04:55:43:063PM1040504021Dmitri MossessianPlasma.

Engineering Operator Comments
ShotTimeTypeStatusComment
110:00:13:560AMTestOk
212:11:14:440PMTestOkMSE Test
312:24:44:560PMTestOkMSE Test
412:40:30:883PMTestOkMSE Test
512:53:03:770PMTestOkMSE Test
601:06:37:200PMTestOkMSE Test
701:22:23:527PMPlasmaOk
801:34:58:397PMPlasmaOk
901:54:04:893PMPlasmaBadOH1 Power Supply Fault
1002:11:10:550PMPlasmaOk
1102:23:48:433PMPlasmaOk
1202:36:16:210PMPlasmaOk
1302:54:31:393PMPlasmaOk
1403:07:13:107PMPlasmaOk
1503:19:51:150PMPlasmaOk
1603:35:26:690PMPlasmaOk
1703:57:39:757PMPlasmaOk
1804:15:27:283PMPlasmaOk
1904:28:07:070PMPlasmaOk
2004:40:59:027PMPlasmaOk
2104:53:51:690PMPlasmaOk
2205:10:05:163PMPlasmaOk