| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Steve Wukitch |
| Physics operator(s): | Bill Rowan |
| Engineering operator(s): | Gary Dekow |
| Engineering Operator Run Comment |
| MP#390 Evaluation of D(He3) minority heating; Sl:Wukitch; PO:Rowan; EO:D |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:05:693PM |
| Author: Steve Wukitch |
| Session leader: S. Wukitch Physics operator: W. Rowan MP#390 Evaluation of D(He3) minority heating If available, ECDC Overnight in D2, stopping by 07:00 Run begins at 09:00 and ends at 17:00. Power systems the same as 1040504021 A-coils as on 1040504021 Gas setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid enabled (PG1) leave B-side upper with 15 psi He3 Hybrid enabled (PG2) fill C-side with 30 psi D2 Hybrid enabled (PG3) Enable the following gate valves, assuming no vacuum problems: ECE, VUV, DNB RF: Transmitters #1,2,3 and 4 in RUN-ON by 08:30 ----------------------------------------------------------------------------------- Plan - Try to get J3 working, and then get J3 and J4 working together. Depending on success, try for H-modes at 3.4 T and ITBs at 2.8 T ----------------------------------------------------------------------------------- 001 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [.9,1.25] sec J4: 1.0 MW [1.2,1.45] sec result: early disruption next: retry 002 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [.9,1.25] sec J4: 1.0 MW [1.2,1.45] sec result: plasma - ohmic H-mode J3: max faults J4: no attempt 003 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - ohmic H-mode late J3: max faults J4: ran 2 faults next: increase power ramp rate on #3 004 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults J4: ran next: retune stub slightly 005 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults J4: ran evidence of central mode conversion on both FRCECE and PCI 006 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults J4: ran evidence of central mode conversion on both FRCECE and PCI 007 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 0.9 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults but 12 msec pulse (longest yet) J4: ran 008 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 1.1 MW [1.15,1.45] sec J4: 1.1 MW [.9,1.2] sec result: plasma - early disruption J3: - J4: ran 009 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 1.1 MW [1.15,1.45] sec J4: 1.1 MW [.7,1.2] sec result: plasma J3: ran max faults but 40 msec pulse J4: ran 010 Ip~1 MA, BT~5.2 T, nl04~0.8, 3He~0.06 sec J3: 1.1 MW [1.15,1.45] sec J4: 1.1 MW [.7,1.2] sec result: plasma J3: ran max faults (20 msec pulse) J4: ran 011 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.06 sec J3: 1.1 MW [1.1,1.45] sec J4: 1.1 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran 012 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.06 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran 013 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.1 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran note: J3 may be oscillating 014 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.1 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran install 100 MHz low pass filter on J3DC0 015 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.1 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran modify J3 output load position 016 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.1 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults (35 msec pulse) J4: ran changed J3 transmitter tune again to eliminate oscillation 017 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma - early disruption J3: - J4: ran 3 faults very nice central mode conversion 018 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran - max faults J4: ran J3 looks worse - change tune again 019 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.4 MW [.7,1.2] sec result: plasma J3: - J4: ran - xbar fired 020 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.4 MW [.7,1.2] sec result: plasma -early disruption J3: - J4: ran 2 faults 021 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma J3: ran few faults (~0.3 sec pulse) J4: ran max faults J3 seems to be improved following tuning adjustment 022 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma J3: ran 5 faults in addition to programmed modulation J4: ran moved FMIT#3 FPA output load to similar position as FMIT#4 023 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma J3: ran max faults J4: ran change ferrite position on FMIT#3 024 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma - ferrite position change seemed to make #3 worse J3: ran max faults J4: ran change ferrite position (opposite to 023) on FMIT#3 025 Ip~1 MA, BT~5.1 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma - ferrite position change seemed to make #3 better phase feedback was okay - ran together for 0.03 sec J3: ran max faults J4: ran change ferrite position (another 0.5" in same direction) on FMIT#3 026 Ip~1 MA, BT~5.6 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma - ferrite position change seemed to make #3 better J3: ran max faults when overlapped J4: ran J3 is now limited to ~0.9 MW now need to make them run together 027 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped slowed power ramp rate on J3 028 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped 029 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped slow power ramp rate on J4 030 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.2 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped 031 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.2 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped Run Summary: We made progress towards 50 MHz operation of J antenna. We have established that both transmitters can couple to their respective elements and have limited data suggesting they will operate simultaneously. I think we have clearly identified that the previous DC break was the source of the RF noise and the transmitter tune is the likely culprit for the inability to couple to the plasma. The difficulty in running both transmitters simultaneously is also likely a result of the transmitter tune. It appears the transmitters oscillate at frequencies in addition to 50 MHz when operated into plasma. This may be a result of using a stub to match the dummy load to 50 Ohms that results in a delicate transmitter configuration. Since J4 was operating reliably, we scanned both the B-field and 3He concentration to investigate mode conversion physics. In a series of discharges, we scanned the mode conversion such that the PCI signal shows both the IBW and ICW in one discharge and IBW and ICW isolated in two other discharges. This marks the first conclusive evidence of IBW measured by the PCI and the mapping of the mode conversion region. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:50:207PM |
| Author: Bill Rowan |
| Physics Operator Summary for Wednesday, May 5, 2004. Run 1040505. Purpose: MP#390 Evaluation of D(He3) minority heating Session leader: S. Wukitch Physics operator: W. Rowan Summary------------------------------------------------------------------------ Began the run from shot 1040504021. Loaded the entire shot -- including the startup. There were no changes to the startup during the day, and it was stable. There were some early disruptions due to injections. Injections caused disruptions on several shots at approximately 1s. The RF was on at that time. A few hots spots were also observed in the divertor on the video view of j-port at that time. RXL was changed slightly to see what affect it had on the hot spots. There was no noticable effect on the hot spots but the rate of disruptions decreased. The RF was working better by that time as well so there is no conclusion to this -- just a thought. He3 was puffed from PG2. The typical pulse length was approximately 50 ms, but that was lengthed and shorted during the run. One software glitch led to a no-power shot. That shot was overwritten by the following shot so there is no number for it -- it is the first attempt at 011. BT was varied over the range 5.1 T to 5.7 T. Density feedback concerned Jim throughout the day, but there was only one problem due to the feedback and that shot (029) did not end early. Score Card--------------------------------------------------------------------- Plasma 26 (002,003,004,005,006,007,009,010,011,013,014,015, 016,018,019,021,022,023,024,025,026,027,028,029, 030,031) Disruption due to injection 05 (001,008,012,017,020) No power shots (01) Fizzles 00 Duds 00 Total 31, note: no number for the only no power shot Experimental Setup------------------------------------------------------------- If available, ECDC Overnight in D2, stopping by 07:00 Run begins at 09:00 and ends at 17:00. Power systems the same as 1040504021 A-coils as on 1040504021 Gas setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid enabled (PG1) leave B-side upper with 15 psi He3 Hybrid enabled (PG2) fill C-side with 30 psi D2 Hybrid enabled (PG3) Enable the following gate valves, assuming no vacuum problems: ECE, VUV, DNB RF: Transmitters #1,2,3 and 4 in RUN-ON by 08:30 Run Plan -------------------------------------------------------------------- Try to get J3 working, and then get J3 and J4 working together. Detailed Log----------------------------------------------------------------- Loaded from shot 1040504021. Load/Clean: Load at 5-May-2004 08:13:41.00 001. Plasma. Disruption at 0.6 s SXR shows sharp signal increase at 0.55. That continues until the disruption. SXR also shows a sharp increase at 0.42 s which recovers to the usual low signal. There were two injections after 0.35 s. The second caused the disruption. Next shot. No PCS changes 002. Plasma. Continued all the way through ramp down. Next shot. No PCS changes. 003. Plasma. Next shot. No PCS changes 004. Plasma. Next shot. No PCS changes. 005. Plasma Next shot. No PCS changes. 006. Plasma Next shot. No PCS changes. 007. Plasma. Next shot. No PCS changes 008. Plasma. Disruption at 1.1 s Disruption occurred during RF Sharp increase in SXR before the disruption. This disruption was due to an injection. Next shot. Increase the length of the argon pulse (PG1) from 35 ms to 45 ms. Still starts at 0.3s. 009. Plasma. Next shot. Increase the length of the argon pulse (PG1) from 45 ms to 50 ms. 010. Plasma. Next shot. Increase the BT to 5.4 T. ITF increased to -147050 A 011. Plasma. First attempt at 011 was a no power shot due to a software problem. The second attempt was this shot. BT = 5.4 T Next shot. No PCS changes. 012. Plasma. Disruption at 1.0 s Disruption occurred during the RF pulse Increase in SXR before the disruption. Looks like an injection. Next shot. No PCS changes. 013. Plasma. Full length IP flat top. Disruption during rampdown, 1.7 s. Next shot. Increased the He3 pulse length (PG2) from 60 ms to 100 ms. Still starts at 0.3 s 014. Plasma. Full length -- all the way through ramp down. Next shot. No PCS changes 015. Plasma Full length. Next shot. No PCS changes. 016. Plasma Next shot.N Increased the He3 pulse length (PG2) from 100 ms to 150 ms. Still starts at 0.3 017. Plasma. Disruption at 1.1s Similar to previous disruptions. 012 and 008. Next shot. No PCS changes. 018. Plasma Next shot. No PCS changes. 019. Plasma Next shot. No PCS shots. 020. Plasma. Disruption at 1.0s Next shot. No PCS changes. 021. Plasma. Next shot. Change RXL slightly. Ramp from 0.008 at 0.912s to 0.006 at 1.49. Changed from 0.008 plateau in demand 022. Plasma Next shot. No PCS changes. 023. Plasma Next shot. Change the TF to 5.1 T ITF changed to -138900 024. Plasma TF = 5.1 T Next shot. No PCS changes. 025. Plasma. Marfe ending around 0.7s. Next shot. TF change. New TF=5.6T. ITF = -152500 026. Plasma. TF=5.6T Next shot. Increase TF to 5.7T. Increase ITF to 155215 027. Plasma TF=5.7T Next shot. No PCS changes/ 028. Plasma Next shot. No PCS changes. 029. Plasma Density feedback was a problem for the first time today. Next shot. No PCS changes 030. Plasma Next shot. Reduce He3 pulse (PG2) from 150 ms to 30 ms. 031. Plasma. Last shot. |
| Session Leader Comments | |||
| May 5 2004 09:05:55:740AM | 1040505001 | Steve Wukitch | 001 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [.9,1.25] sec J4: 1.0 MW [1.2,1.45] sec result: early disruption next: retry |
| May 5 2004 09:28:56:990AM | 1040505002 | Steve Wukitch | 002 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [.9,1.25] sec J4: 1.0 MW [1.2,1.45] sec result: plasma - ohmic H-mode J3: max faults J4: no attempt |
| May 5 2004 09:33:28:283AM | 1040505003 | Steve Wukitch | 003 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - ohmic H-mode late J3: max faults J4: ran 2 faults next: increase power ramp rate on #3 |
| May 5 2004 09:57:00:263AM | 1040505004 | Steve Wukitch | 004 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults J4: ran next: retune stub slightly |
| May 5 2004 10:15:29:560AM | 1040505005 | Steve Wukitch | 005 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.5 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults J4: ran |
| May 5 2004 10:54:49:947AM | 1040505007 | Steve Wukitch | 007 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 0.9 MW [1.15,1.45] sec J4: 1.0 MW [.9,1.2] sec result: plasma - H-modes J3: ran max faults but 12 msec pulse (longest yet) J4: ran |
| May 5 2004 10:56:34:153AM | 1040505008 | Steve Wukitch | 008 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 1.1 MW [1.15,1.45] sec J4: 1.1 MW [.9,1.2] sec result: plasma - early disruption J3: - J4: ran |
| May 5 2004 11:04:59:307AM | 1040505009 | Steve Wukitch | 009 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 1.1 MW [1.15,1.45] sec J4: 1.1 MW [.7,1.2] sec result: plasma J3: ran max faults but 40 msec pulse J4: ran |
| May 5 2004 11:29:28:580AM | 1040505010 | Steve Wukitch | 010 Ip~1 MA, BT~5.2 T, nl04~0.8 J3: 1.1 MW [1.15,1.45] sec J4: 1.1 MW [.7,1.2] sec result: plasma J3: ran max faults (20 msec pulse) J4: ran |
| May 5 2004 11:53:59:647AM | 1040505011 | Steve Wukitch | 011 Ip~1 MA, BT~5.4 T, nl04~0.8 J3: 1.1 MW [1.1,1.45] sec J4: 1.1 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran |
| May 5 2004 12:16:15:183PM | 1040505012 | Steve Wukitch | 012 Ip~1 MA, BT~5.4 T, nl04~0.8 J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma - early disruption J3: ran max faults J4: ran |
| May 5 2004 12:37:48:037PM | 1040505013 | Steve Wukitch | 013 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.1 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran note: J3 may be oscillating |
| May 5 2004 12:38:15:067PM | 1040505014 | Steve Wukitch | 014 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.1 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran install 100 MHz low pass filter on J3DC0 |
| May 5 2004 01:05:34:370PM | 1040505015 | Steve Wukitch | 015 Ip~1 MA, BT~5.4 T, nl04~0.8 J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults J4: ran modify J3 output load position |
| May 5 2004 01:07:06:317PM | 1040505016 | Steve Wukitch | 016 Ip~1 MA, BT~5.4 T, nl04~0.8 J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran max faults (35 msec pulse) J4: ran |
| May 5 2004 01:27:34:220PM | 1040505017 | Steve Wukitch | changed J3 transmitter tune again to eliminate oscillation 017 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma - early disruption J3: - J4: ran 3 faults |
| May 5 2004 01:30:44:367PM | 1040505017 | Steve Wukitch | changed J3 transmitter tune again to eliminate oscillation 017 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma - early disruption J3: - J4: ran 3 faults very nice central mode conversion |
| May 5 2004 01:59:07:833PM | 1040505018 | Steve Wukitch | 018 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.25 MW [.7,1.2] sec result: plasma J3: ran - max faults J4: ran J3 looks worse - change tune again |
| May 5 2004 02:06:43:773PM | 1040505019 | Steve Wukitch | 019 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.4 MW [.7,1.2] sec result: plasma J3: - J4: ran - xbar fired J4 bias tripped |
| May 5 2004 02:11:43:740PM | 1040505020 | Steve Wukitch | 020 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [1.1,1.45] sec J4: 1.4 MW [.7,1.2] sec result: plasma -early disruption J3: - J4: ran 2 faults |
| May 5 2004 02:49:58:273PM | 1040505021 | Steve Wukitch | 021 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma J3: ran few faults (~0.3 sec pulse) J4: ran max faults J3 seems to be improved following tuning adjustment 0 |
| May 5 2004 02:51:33:940PM | 1040505022 | Steve Wukitch | 022 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma J3: ran 5 faults in addition to programmed modulation J4: ran moved FMIT#3 FPA output load to similar position as FMIT#4 |
| May 5 2004 03:05:02:340PM | 1040505023 | Steve Wukitch | 023 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma J3: ran max faults J4: ran change ferrite position on FMIT#3 |
| May 5 2004 03:12:40:137PM | 1040505024 | Steve Wukitch | 024 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma - ferrite position change seemed to make #3 worse J3: ran max faults J4: ran change ferrite position (opposite to 023) on FMIT#3 |
| May 5 2004 03:29:33:103PM | 1040505025 | Steve Wukitch | 025 Ip~1 MA, BT~5.4 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma - ferrite position change seemed to make #3 better phase feedback was okay - ran together for 0.03 sec J3: ran max faults J4: ran change ferrite position (another 0.5" in same direction) on FMIT#3 |
| May 5 2004 04:06:45:517PM | 1040505026 | Steve Wukitch | 026 Ip~1 MA, BT~5.6 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [1.0,1.45] sec result: plasma - ferrite position change seemed to make #3 better J3: ran max faults when overlapped J4: ran J3 is now limited to ~0.9 MW now need to make them run together |
| May 5 2004 04:29:31:177PM | 1040505027 | Steve Wukitch | 027 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped slowed power ramp rate on J3 |
| May 5 2004 04:46:01:347PM | 1040505028 | Steve Wukitch | 028 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped retune J4 |
| May 5 2004 04:50:42:977PM | 1040505029 | Steve Wukitch | 029 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.4 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped slow power ramp rate on J4 |
| May 5 2004 05:08:58:693PM | 1040505030 | Steve Wukitch | 030 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.2 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped |
| May 5 2004 05:09:24:723PM | 1040505031 | Steve Wukitch | 031 Ip~1 MA, BT~5.7 T, nl04~0.8, 3He~0.15 sec J3: 1.0 MW [0.6,1.2] sec J4: 1.2 MW [0.8,1.45] sec result: plasma J3: ran max faults when overlapped J4: ran max faults when overlapped |
| Physics Operator Comments | |||
| May 5 2004 08:15:45:640AM | Bill Rowan | Session leader: S. Wukitch Physics operator: W. Rowan MP#390 Evaluation of D(He3) minority heating If available, ECDC Overnight in D2, stopping by 07:00 Run begins at 09:00 and ends at 17:00. Power systems the same as 1040504021 A-coils as on 1040504021 Gas setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid enabled (PG1) leave B-side upper with 15 psi He3 Hybrid enabled (PG2) fill C-side with 30 psi D2 Hybrid enabled (PG3) Enable the following gate valves, assuming no vacuum problems: ECE, VUV, DNB RF: Transmitters #1,2,3 and 4 in RUN-ON by 08:30 ----------------------------------------------------------------------------------- Plan - Try to get J3 working, and then get J3 and J4 working together. Loaded from shot 1040504021. Load/Clean: Load at 5-May-2004 08:13:41.00 | |
| May 5 2004 09:06:49:817AM | 1040505001 | Bill Rowan | 001. Plasma. Disruption at 0.6 s SXR shows sharp signal increase at 0.55. That continues until the disruption. SXR also shows a sharp increase at 0.42 s which recovers to the usual low signal. There were two injections after 0.35 s. The second caused the disruption. Next shot. No PCS changes |
| May 5 2004 09:13:27:843AM | 1040505002 | Bill Rowan | 002. Plasma. Continued all the way through ramp down. |
| May 5 2004 09:29:50:770AM | 1040505002 | Bill Rowan | Next shot. No PCS changes. |
| May 5 2004 09:30:36:860AM | 1040505003 | Bill Rowan | 003. Plasma. |
| May 5 2004 09:34:01:580AM | 1040505003 | Bill Rowan | Next shot. No PCS changes |
| May 5 2004 09:50:29:190AM | 1040505004 | Bill Rowan | 004. Plasma. Next shot. No PCS changes. |
| May 5 2004 10:01:41:820AM | 1040505005 | Bill Rowan | 005. Plasma Next shot. No PCS changes. |
| May 5 2004 10:15:30:920AM | 1040505006 | Bill Rowan | 006. Plasma Next shot. No PCS changes. |
| May 5 2004 10:37:54:653AM | 1040505007 | Bill Rowan | 007. Plasma. Next shot. No PCS changes |
| May 5 2004 10:44:50:980AM | 1040505008 | Bill Rowan | 008. Plasma. Disruption at 1.1 s Disruption occurred during RF Sharp increase in SXR before the disruption. This disruption was due to an injection. Next shot. Increase the length of the argon pulse (PG1) from 35 ms to 45 ms. Still starts at 0.3s. |
| May 5 2004 10:59:57:283AM | 1040505009 | Bill Rowan | 009. Plasma. Next shot. Increase the length of the argon pulse (PG1) from 45 ms to 50 ms. |
| May 5 2004 11:23:46:337AM | 1040505010 | Bill Rowan | 010. Plasma. Next shot. Increase the BT to 5.4 T. ITF increased to -147050 A |
| May 5 2004 11:42:21:537AM | 1040505011 | Bill Rowan | Next shot. No PCS changes. |
| May 5 2004 11:54:17:930AM | 1040505011 | Bill Rowan | 011. Plasma. First attempt at 011 was a no power shot due to a software problem. The second attempt was this shot. Bt = 5.4 T |
| May 5 2004 12:05:24:587PM | 1040505012 | Bill Rowan | 012. Plasma. Disruption at 1.0 s Disruption occurred during the RF pulse Increase in SXR before the disruption. Looks like an injection. Next shot. No PCS changes. |
| May 5 2004 12:21:29:430PM | 1040505013 | Bill Rowan | 013. Plasma. Full length IP flat top. Disruption during rampdown, 1.7 s. |
| May 5 2004 12:24:08:560PM | 1040505013 | Bill Rowan | Next shot. Increased the He3 pulse length (PG2) from 60 ms to 100 ms. Still starts at 0.3 s |
| May 5 2004 12:34:06:067PM | 1040505014 | Bill Rowan | 014. Plasma. Full length -- all the way through ramp down. |
| May 5 2004 12:40:23:573PM | 1040505014 | Bill Rowan | Next shot. No PCS changes |
| May 5 2004 12:50:23:083PM | 1040505015 | Bill Rowan | 015. Plasma Full length. |
| May 5 2004 12:58:13:163PM | 1040505015 | Bill Rowan | Next shot. No PCS changes. |
| May 5 2004 01:05:49:727PM | 1040505016 | Bill Rowan | 016. Plasma |
| May 5 2004 01:13:49:977PM | 1040505016 | Bill Rowan | Next shot. Increased the He3 pulse length (PG2) from 100 ms to 150 ms. Still starts at 0.3 s |
| May 5 2004 01:25:10:760PM | 1040505017 | Bill Rowan | 017. Plasma. Disruption at 1.1s Similar to previous disruptions. 012 and 008. |
| May 5 2004 01:31:09:380PM | 1040505017 | Bill Rowan | Next shot. No PCS changes. |
| May 5 2004 01:50:22:307PM | 1040505018 | Bill Rowan | 018. Plasma Next shot. No PCS changes. |
| May 5 2004 02:05:29:687PM | 1040505019 | Bill Rowan | 019. Plasma Next shot. No PCS shots. |
| May 5 2004 02:19:33:177PM | 1040505020 | Bill Rowan | 020. Plasma. Disruption at 1.0s Next shot. No PCS changes. |
| May 5 2004 02:25:25:663PM | 1040505021 | Bill Rowan | 021. Plasma. |
| May 5 2004 02:32:03:167PM | 1040505021 | Bill Rowan | Next shot. Change RXL slightly. Ramp from 0.008 at 0.912s to 0.006 at 1.49. Changed from 0.008 plateau in demand |
| May 5 2004 02:47:25:340PM | 1040505022 | Bill Rowan | 022. Plasma Next shot. No PCS changes. |
| May 5 2004 03:00:41:830PM | 1040505023 | Bill Rowan | 023. Plasma Next shot. Change the TF to 5.1 T ITF changed to -138900 |
| May 5 2004 03:16:26:720PM | 1040505024 | Bill Rowan | 024. Plasma TF = 5.1 T Next shot. No PCS changes. |
| May 5 2004 03:29:47:103PM | 1040505025 | Bill Rowan | 025. Plasma. Marfe ending around 0.7s. Next shot. TF change. New TF=5.6T. ITF = -152500 |
| May 5 2004 03:53:48:620PM | 1040505026 | Bill Rowan | 026. Plasma. TF=5.6T |
| May 5 2004 04:02:29:307PM | 1040505026 | Bill Rowan | Next shot. Increase TF to 5.7T. Increase ITF to 155215 |
| May 5 2004 04:20:36:910PM | 1040505027 | Bill Rowan | 027. Plasma TF=5.7T Next shot. No PCS changes |
| May 5 2004 04:23:45:157PM | 1040505028 | Bill Rowan | 028. Plasma |
| May 5 2004 04:31:39:267PM | 1040505028 | Bill Rowan | Next shot. No PCS changes. |
| May 5 2004 04:42:11:730PM | 1040505029 | Bill Rowan | 029. Plasma Density feedback was a problem for the first time today. |
| May 5 2004 04:45:58:283PM | 1040505029 | Bill Rowan | Next shot. No PCS changes |
| May 5 2004 04:51:31:320PM | 1040505030 | Bill Rowan | 030. Plasma |
| May 5 2004 04:59:40:540PM | 1040505030 | Bill Rowan | Next shot. Reduce He3 pulse (PG2) from 150 ms to 30 ms |
| May 5 2004 05:04:27:390PM | 1040505031 | Bill Rowan | 031. Plasma. Last shot. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:57:35:870AM | Plasma | Ok | |
| 2 | 09:10:22:003AM | Plasma | Ok | |
| 3 | 09:27:02:100AM | Plasma | Ok | |
| 4 | 09:43:35:290AM | Plasma | Ok | |
| 5 | 09:56:35:170AM | Plasma | Ok | |
| 6 | 10:10:16:410AM | Plasma | Ok | |
| 7 | 10:22:49:510AM | Plasma | Ok | |
| 8 | 10:35:39:970AM | Plasma | Ok | |
| 9 | 10:54:40:993AM | Plasma | Ok | |
| 10 | 11:08:49:797AM | Plasma | Ok | |
| 11 | 11:24:07:587AM | Plasma | Ok | |
| 12 | 12:00:15:500PM | Plasma | Ok | |
| 13 | 12:15:21:700PM | Plasma | Ok | |
| 14 | 12:27:48:827PM | Plasma | Ok | |
| 15 | 12:44:06:123PM | Plasma | Ok | |
| 16 | 01:01:21:523PM | Plasma | Ok | |
| 17 | 01:20:21:123PM | Plasma | Ok | |
| 18 | 01:33:27:760PM | Plasma | Ok | |
| 19 | 01:53:43:870PM | Plasma | Ok | |
| 20 | 02:08:12:927PM | Plasma | Ok | |
| 21 | 02:20:59:860PM | Plasma | Ok | |
| 22 | 02:33:38:430PM | Plasma | Ok | |
| 23 | 02:49:48:710PM | Plasma | Ok | |
| 24 | 03:03:58:573PM | Plasma | Ok | |
| 25 | 03:17:57:987PM | Plasma | Ok | |
| 26 | 03:50:18:220PM | Plasma | Ok | |
| 27 | 04:06:39:580PM | Plasma | Ok | |
| 28 | 04:21:30:923PM | Plasma | Ok | |
| 29 | 04:34:23:213PM | Plasma | Ok | |
| 30 | 04:49:08:497PM | Plasma | Ok | |
| 31 | 05:02:16:457PM | Plasma | Ok | |