Alcator C-Mod Run 1050609 Information

Back to runs

Miniproposals
Miniproposal:326
Date Filed: 8/26/2002
Title:D, E, and J-port Antenna Evaluation and Comparison
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-30)

Operators
Session leader(s):Steve Wukitch
Physics operator(s):Robert Granetz,Joseph Snipes,Joseph Snipes
Engineering operator(s):Bill Cochran,Gary Dekow,Ed Fitzgerald

Engineering Operator Run Comment
RF Conditioning in Helium

Session Leader Plans
Entered: Jun 9 2005 07:06:02:133AM
Author: Steve Wukitch
Plan:

Investigate antenna voltage and power characteristics in He
discharges. First set of discharges will be LSN fiducials in He to
obtain power and voltage characteristics. We will perform a similar
set of discharges for USN and then investigate the pressure limit in
He for the antennas by raising the density.

Physics Operators Plans
Entered: Jun 9 2005 10:37:07:680AM
Author: Robert Granetz

Engineering setup for Thursday, 09 June 2005

MP #326: RF Antenna comparison (in helium, although not called for in the MP)

Session leader: S. Wukitch/Y. Lin
Physics operator: R. Granetz

Overnight ECDC in helium; bake at 60 C.

Run begins at 09:00 and ends at 17:00.
Power systems as on 1050608021 (1.0 MA, 5.4 T, SNL fiducial)

A-coil configuration: normal [+Dtop -Dbot -Jtop +Jbot] and enabled.

Gas Setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper with whatever Hybrid disabled
fill B-main (C-side) with 30 psi He Hybrid enabled (PG3)
NINJA not used today

Enable the following gate valves and shutters, assuming no vacuum problems:
ECE, VUV, Z-bolo shutters

-------------------------------------------------------------------------------
ICRF Setup: All transmitters in run on at 08:30.

-------------------------------------------------------------------------------
Run plan: Continue with Wednesday's RF conditioning in helium plasmas.

Session Leader Summaries
Entered: Jun 10 2005 08:56:36:037AM
Author: Steve Wukitch
Run summary

We had significant improvement in the D antenna operation through
conditioning in He. With the switch back to D plasmas, the antenna
performance did decrease but appeared to be recovering (027). We
reached 0.75 MW for the first time with D antenna since the vent to
remove the LH coupler. E antenna also ran well up to 45 kV in He
plasmas and showed decreased reliability with the switch back to D
plasmas. We were unable to reach high enough neutral pressures in He
discharges to determine if the neutral pressure limit was different
from D plasmas. This scan showed J antenna could couple into high
density plasmas without reliability issues with low neutral pressure.

Physics Operator Summaries
Entered: Jun 9 2005 06:13:17:350PM
Author: Robert Granetz
Run summary for Thursday 09 June 2005:

MP #326: RF Antenna comparison (in helium plasmas, although not called for
in the MP)

Session leader: Y. Lin/S. Wukitch
Physics operator: R. Granetz

The machine ran well today. Most of the run consisted of 1 MA, 5.4 T,
lower single null discharges in helium plasmas. D, E, and J ran on every
shot. See the session leader's summary for the RF performance. H/(H+D)
was 10-12% in the helium plasmas. After shot 23 we changed to deuterium
plasmas for the remainder of the run. H/(H+D) was 7-11% for those
discharges. This was deemed good enough to proceed with boronization after
the run. On shot 27 a lithium pellet was fired in at t=1.45 s (seen on
DANT video frame 43). The last three shots of the day were apparently done
in by a faulty capillary valve on the NINJA system, which played havoc with
the torus pressure. Needless to say, the NINJA system must remain pumped
out until the bad valve is isolated.

Scorecard: 24 plasmas
3 fizzles
3 duds
0 tests or no-power shot cycles
----------
30 total shot cycles

Session Leader Comments
Jun 9 2005 10:23:14:837AM1050609001Steve Wukitch001 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.5 MW [.5,1.7]sec
E: 1 MW [0.5,1.5]sec
J: 2 MW [0.5,1.4]sec
result: plasma - still a fair amount of D2 around and a 20% increase
in density with application of RF
D: ran max faults w/ some longer stretches at full power
E: ran 130 msec at >1MW
J: ran

Jun 9 2005 10:22:35:900AM1050609002Steve Wukitch002 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.5 MW [.5,1.7]sec
E: 1 MW [0.5,1.5]sec
J: 2 MW [0.5,1.4]sec
result: plasma - still a fair amount of D2 around and a 20% increase
in density with application of RF - where is it coming from?
D: ran max faults
E: ran 11 faults
J: ran

Jun 9 2005 10:22:09:290AM1050609003Steve Wukitch003 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.5 MW [.5,1.7]sec
E: 1 MW [0.5,1.5]sec
J: 2 MW [0.5,1.4]sec
result: plasma - density increase is before RF (touched inner wall)
D: ran max faults
E: ran almost all voltage limits
J: ran
increase E voltage limit

Jun 9 2005 10:20:53:163AM1050609004Steve Wukitch004 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.5 MW [.5,1.7]sec
E: 1 MW [0.5,1.5]sec
J: 2 MW [0.5,1.4]sec
result: plasma - density increase is before RF (touched inner wall)
D: ran max faults
E: ran almost all voltage limits
J: ran

Jun 9 2005 10:33:13:650AM1050609005Steve Wukitch005 NTP
Jun 9 2005 11:02:04:150AM1050609006Steve Wukitch006 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.5 MW [.5,1.7]sec
E: 1 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - density increase is before RF (touched inner wall)
D: ran max faults
E: ran almost all voltage limits
J: ran

Jun 9 2005 11:28:51:400AM1050609007Steve Wukitch007 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - no H-mode
D: ran max faults
E: ran 1 fault
J: ran

Jun 9 2005 11:29:32:163AM1050609008Steve Wukitch008 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - two H-mode
D: ran max faults - looks worse than 007
E: ran 6 faults - looks as good as USN
J: ran

Jun 9 2005 11:30:58:850AM1050609009Steve Wukitch009 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - H-modes
D: ran max faults - but improved
E: ran 7 faults - several are voltage related
J: ran

Jun 9 2005 11:45:44:243AM1050609010Steve Wukitch010 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - H-modes
D: ran max faults - better in the early part of pulse
E: ran 7 faults - several are voltage limit related
J: ran

Jun 9 2005 12:03:45:363PM1050609011Steve Wukitch011 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - no H-modes - higher density (nl04~1.1)
D: ran max faults
E: ran 10 faults
J: ran
raise density
Jun 9 2005 12:12:58:710PM1050609012Steve Wukitch012 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - no H-modes - higher density (nl04~1.4)
D: ran max faults - best shot yet
E: ran 4 faults
J: ran
raise density
Jun 9 2005 12:30:09:337PM1050609013Steve Wukitch013 NTP
Jun 9 2005 12:49:08:553PM1050609014Steve Wukitch014 NTP
Jun 9 2005 01:12:34:900PM1050609016Steve Wukitch016 early disruption
Jun 9 2005 01:47:55:210PM1050609017Steve Wukitch017 early disruption
Jun 9 2005 02:01:36:007PM1050609018Steve Wukitch018 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - H-mode - 1ower density (nl04~1.1)
D: ran max faults - antenna voltage is higher
E: ran 2 faults
J: ran

Jun 9 2005 02:03:48:117PM1050609019Steve Wukitch019 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - early disruption at 0.7 sec- 1ower density (nl04~0.9)
D: ran faults
E: ran 1 faults
J: ran

Jun 9 2005 02:58:29:070PM1050609020Steve Wukitch020 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma
D: ran max faults - ugly
E: ran max faults - ugly
J: ran

Jun 9 2005 03:20:13:743PM1050609021Steve Wukitch021 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma
D: ran faults - improvement
E: ran 11 faults
J: ran

Jun 9 2005 03:21:09:663PM1050609022Steve Wukitch022 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma
D: ran faults improving
E: ran faults much improved
J: ran

Jun 9 2005 03:22:15:850PM1050609023Steve Wukitch023 Ip~1 MA, BT~5.4 T, fiducial, LSN, He plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma
D: ran faults
E: ran 9 faults
J: ran

Jun 9 2005 03:27:28:070PM1050609025Steve Wukitch025 Ip~1 MA, BT~5.4 T, fiducial, LSN, D plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - H-modes
D: ran faults - not as bad as it could have been
E: ran 21 faults
J: ran

Jun 9 2005 03:45:38:617PM1050609026Steve Wukitch026 Ip~1 MA, BT~5.4 T, fiducial, LSN, D plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - H-modes
D: ran faults - not as bad as it could have been
E: ran faults - improved as pulse progressed
J: ran

Jun 9 2005 03:54:42:977PM1050609027Steve Wukitch027 Ip~1 MA, BT~5.4 T, fiducial, LSN, D plasma
D: 0.75 MW [.5,1.7]sec
E: 1.25 MW [0.5,1.5]sec
J: 1 MW [0.5,1.4]sec
result: plasma - H-modes
D: ran faults - bit better
E: ran 17 faults
J: ran

Jun 9 2005 04:40:03:197PM1050609028Steve Wukitch028 fizzle

Physics Operator Comments
Jun 9 2005 10:08:53:900AM1050609001Robert GranetzPlasma. Good shot. Helium plasma, 1 MA, 5.4 T, nl_04=1.0e20 m-2 target. Prf=3-4 MW. Didn't get H/D.

Break for cell access (TCI, TS, and tour for our new contract monitor).

Next shot: repeat, no changes




Jun 9 2005 10:13:40:883AM1050609002Robert GranetzPlasma. Good shot. Helium. Prf=3-4 MW. J-port system is running very well.
E has multiple faults at 1 MW. D is faulting alot at 0.5 MW.

Very late breakdown (just like shot 001).

Next shot: add 2 ms to prefill (to 30 ms)
Jun 9 2005 10:14:04:540AM1050609003Robert GranetzPlasma. Good shot. Helium. Prf=3-4 MW. Very similar to preceding shots today.
Breakdown was earlier. Plasma diverts then briefly limits again around 0.37 s.
H/(H+D)=10%.

Next shot: tweak CLEARIN out a bit around 0.37 s.
Jun 9 2005 10:18:59:930AM1050609004Robert GranetzPlasma. Good shot. Helium. Prf=3-4 MW. H/(H+D)=10%.
Breakdown is getting later again.

Cell access for TS and others.

Next shot: repeat, no changes.
Jun 9 2005 10:33:20:163AM1050609005Robert GranetzDud.

Next shot: increase prefill another 2 ms.
Jun 9 2005 11:09:56:477AM1050609006Robert GranetzPlasma. Good shot. Helium. J=1 MW, E=1 MW (only a couple of faults), D=0.5 MW.
H/D failed because the associated A14 digitizer failed.

Next shot: repeat, no PCS changes.
Jun 9 2005 11:08:52:803AM1050609007Robert GranetzPlasma. Good shot. Helium. J=1 MW, E=1 MW (only a couple of faults), D=0.75 MW.
H/D failed again.

Next shot: repeat, no PCS changes. Joe Bosco is changing the A14 digitizer used
by the H/D diagnostic for the next shot.
Jun 9 2005 11:24:26:663AM1050609008Robert GranetzPlasma. Good shot. Helium. J=1 MW, E=1.4 MW (only a couple of faults), D=0.75 MW.
H/D doesn't look right.

Next shot: repeat, no PCS changes.
Jun 9 2005 11:36:57:960AM1050609009Robert GranetzPlasma. Good shot. Helium. J=1.0 Mw, E=1.4 MW, D=0.75 MW.

H/D failed. Joe Bosco is pulling out the module and comparing
its settings to a replacement module.

Next shot: no PCS changes.
Jun 9 2005 11:48:40:710AM1050609010Robert GranetzPlasma. Disrupted at t=1.58 s. Helium. RF same as preceding shots.
No video data.

The A14 for the H/D is being swapped back to the original digitizer.

Next shot: raise nl_04 from 1.0 to 1.2e20 m-2.
Jun 9 2005 12:02:34:233PM1050609011Robert GranetzPlasma. Good shot. Density excursion occurred around t=0.4, but it was back to the desired
value by 0.5 s. There's a hot spot showing up on the outboard limiter near H-port.
H/(H+D)=10%.

Next shot: increase nl_04 to 1.4e20 m-2.
Jun 9 2005 12:11:37:210PM1050609012Robert GranetzPlasma. Good shot. Prf=2.5-3 MW. Density excursion is getting more pronounced.

Next shot: raise nl_04 to 1.6e20 m-2.
Jun 9 2005 12:20:31:757PM1050609013Robert GranetzFizzle. Very weak, very late.

Cell access for various people.

Next shot: increase pre-fill by another 2 ms.
Jun 9 2005 12:46:39:960PM1050609014Robert GranetzDud.

Next shot: increase pre-fill another 2 ms (to 36 ms).
Jun 9 2005 01:06:51:930PM1050609015Robert GranetzPlasma. Good shot. Got the higher density during the RF. E-port has improved quite
a bit and essentially looks ready for prime time. H/(H+D)=10%.

Next shot: raise nl_04 to 1.8e20 m-2. Increase pre-fill another 1 ms.
Jun 9 2005 01:18:04:697PM1050609016Robert GranetzPlasma. Disrupted early (t=0.38 s). Looked very resistive. JANT video view
shows numerous dust particulates (frame 11).

Next shot: repeat, no PCS changes.
Jun 9 2005 01:39:43:053PM1050609017Robert GranetzPlasma. Another resistive shot with an early disruption. More particulates on the
JANT view.

Next shot: try once more. If that still disrupts early, then reduce the density.
On second thought, Steve wants to go down to nl_04=1.1e20 m-2 for the
next shot.
Jun 9 2005 01:53:07:650PM1050609018Robert GranetzPlasma. Good shot, full length at the lower density. Prf=2-3 MW.
H/(H+D) dropped to 7-8%.

Next shot: reduce nl_04 to 0.9e20 m-2.
Jun 9 2005 02:08:25:383PM1050609019Robert GranetzPlasma. Disrupted at t=0.69 s. Not sure why.

Next shot: try again, no changes.
Jun 9 2005 02:22:25:680PM1050609020Robert GranetzPlasma. Good shot. E-port didn't do well on this shot. D-port did worse than it has been.
H/(H+D)=9%.

Next shot: at Bruce's request, keep the torus GV closed during the shot and for 5 minutes
after the shot.
Jun 9 2005 02:35:50:350PM1050609021Robert GranetzPlasma. Good shot. Prf=2-3 MW. H/(H+D)=8-11%.
The torus gate valves are remaining closed during and after the shot for 5 minutes.

Next shot: repeat.
Jun 9 2005 02:53:40:163PM1050609022Robert GranetzPlasma. Good shot. Late breakdown.

Next shot: no changes.
Jun 9 2005 03:08:00:540PM1050609023Robert GranetzPlasma. Good shot. Helium (last one for today). H/(H+D)=10-12%. Zeff=2.7-2.8.

Next shot: switch to deuterium plasmas and observe H/D, as well as the antenna
performance. Also, I zeroed the very early gas preprogramming in segment 1
(per Steve Wolfe's suggestion).
Jun 9 2005 03:22:29:600PM1050609024Robert GranetzPlasma. Good shot. First deuterium plasma (helium previously). H/(H+D)=9-10%. RF performance seems
identical to earlier helium shots.

Next shot: repeat, no changes.
Jun 9 2005 03:40:07:697PM1050609025Robert GranetzPlasma. Good shot. Deuterium plasma. H/(H+D)= 8% -> 9% -> 11%.

Next shot: same, except Brock will be firing the LPI at t=1.45 s.
Jun 9 2005 03:50:40:447PM1050609026Robert GranetzPlasma. Good shot. Deuterium plasma. RF is similar. No H/D.
LPI didn't actually fire.

Next shot: LPI will try again. NINJA will also puff some D2.
Jun 9 2005 04:04:15:180PM1050609027Robert GranetzPlasma. Good shot. Deuterium plasma. H/(H+D)=7-10%.
LPI fired at 1.45 s...got a snake. NINJA didn't seem to fire.

Next shot: repeat. No more LPI today. NINJA will try again.
Jun 9 2005 04:40:26:383PM1050609027Robert GranetzThe lithium pellet ablation trail can be seen in the DANT view, frame 43.
Jun 9 2005 04:12:32:710PM1050609028Robert GranetzFizzle. Torus pressure was higher in CHECK state than it has been today. Pre-fill pressure
was high on this shot. And the torus pressure alarmed after the shot (gate valves are still
being kept closed for 5 minutes after the shot).

Next shot: reduce pre-fill by 3 ms.
Jun 9 2005 04:38:39:587PM1050609028Robert GranetzApparently the NINJA system fired at t=8 s after shot 27 and again at t=8 s after shot 28, and
again 20 minutes after shot 28. There is a delay while the machine is being pumped out. The
NINJA system has been turned off.
Jun 9 2005 04:57:17:367PM1050609029Robert GranetzFizzle. Pretty strong light signals, but the pressure was somewhat high. There seems
to be another source of D2 gas from somewhere prior to the shot.

Next shot: reduce pre-fill pulse another 5 ms. This will be the last shot.
Jun 9 2005 05:10:18:150PM1050609030Robert GranetzDud. Torus pressure went up to the -5 scale (or maybe the -4 scale) during CHECK state.

End of run.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:10:31:320AMPlasmaOk
209:33:56:087AMPlasmaOk
309:46:56:133AMPlasmaOk
410:00:01:883AMPlasmaOk
510:27:41:743AMPlasmaOk
610:45:27:553AMPlasmaOk
710:58:29:553AMPlasmaOk
811:11:45:570AMPlasmaOk
911:25:17:600AMPlasmaOk
1011:38:39:070AMPlasmaOk
1111:51:16:087AMPlasmaOk
1212:04:32:253PMPlasmaOk
1312:17:12:180PMPlasmaOk
1412:40:37:570PMPlasmaOk
1512:53:41:540PMPlasmaOk
1601:08:29:790PMPlasmaOk
1701:21:25:523PMPlasmaOk
1801:44:20:540PMPlasmaOk
1901:59:06:303PMPlasmaOk
2002:13:12:947PMPlasmaOk
2102:25:42:303PMPlasmaOk
2202:42:24:837PMPlasmaOk
2302:54:53:193PMPlasmaOk
2403:10:12:757PMPlasmaOk
2503:23:12:900PMPlasmaOk
2603:35:40:757PMPlasmaOk
2703:51:02:727PMPlasmaOk
2804:07:03:210PMPlasmaOk
2904:50:05:007PMPlasmaOk
3005:06:09:180PMPlasmaOk