| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Steve Wukitch |
| Physics operator(s): | Jim Irby |
| Engineering operator(s): | Bill Cochran,Bill Byford,Ed Fitzgerald |
| Engineering Operator Run Comment |
| Run Monday 25-2005 |
| Session Leader Plans |
| Entered: Jul 25 2005 08:30:30:730AM |
| Author: Steve Wukitch |
| MP 390 D(He3) Minority Heating Evaluation at 50 MHz
SL: Wukitch/Lin PO: Granetz Engineering setup as on 1050718005 A-coil configuration: normal [+Dtop -Dbot -Jtop +Jbot] and enabled. Gas Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid disabled (PG1) leave B-side upper 15 psi He3, disabled (PG2) fill B-main with 40 psi D2 Hybrid enabled (PG3) Enable the following: ECE and VUV gate valves, Z-bolo shutters ICRF Setup: transmitters in run-on at 8:30 Plan 1. (10 shots) Start a plasma with B = 3.4 T, Ip = 0.8 MA, nl = 0.8 e20m^-2 (other parameters same as 1050718005, standard fiducial plasma shape). After determining phasing required for (0,pi,pi,0) and CD, quick current scan, 0.6, 0.8, 1.0 MA to establish some baseline shots for future low field operation. 2. (10 shots) Continue He3 puff scan - load 1050718025. B field at 5.2 T, Ip = 1.0 MA, nl04=1.0e20 m^-2. Scan He3 puff shot by shot: 60, 70, 80, 90, 100, 120, 140, 160 ms (adjust field to keep mode conversion near axis). 3. (10 shots) Run constant power and compare J ant with D+E antenna (B field at 5.2 T). Start from the He3 puff time that gave the best J heating from 2. Run constant RF power, J 1.5 MW and D+E at 1.5 MW. (Program fast turn-offs for dW/dt and MC heating study). Scan the He3 puff and generate a similar curve of He3 dependence of heating effectiveness (cf. Fig. 1 in the MP), also use the ratio of Wtot as a proper measure. We will scan the He3 puff up to a point where clear evidence of MC heating is observed. 4. (3 shots) Use the optimal gas puff, vary the antenna phase shot by shot, [0, pi, pi, 0], [0, pi/2, pi, 3/2pi] and [0, -pi/2, pi, -3/2pi], J at 1.5 MW, D+E at 1.5 MW. (B = 5.2 T) 5. (5 shots) Upper single null plasma (load shot 1050629014, lower B field to 5.2 T). Do H-mode power threshold comparison. (same RF waveform as in 1.) (Need as high power as possible from D+E > 2 MW) 6. (5 shots) Overlay all antennas to obtain total 2.5 MW RF (varying the power ratio of J and E). Run several shots near the peak performance of the J heating. (also program fast turn-offs on E and J antennas at two different time points). 7. (5 shots) density scan. Run nl 04 = 0.5, 0.7, .9, 1.1, 1.3 e20 m^-2. Adjusting the He3 puff time to keep nHe3/ne approximately constant. RF waveform same as in 3. |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 29 2005 09:35:02:423AM |
| Author: Steve Wukitch |
| Run Summary:
We finished the 3He scan and found the optimum puff is ~100-120 msec. From the break-in-slope analysis, the 3He fraction is ~5-7%. For concentrations less than this, the heating effectiveness was poorer compared to E antenna at similar power levels. Another observation is that -90 phasing produces the best plasma response in heating and neutrons. Heating phasing is similar but +90 phasing was significantly reduced. The trips in H-mode suggest the He fraction remains relatively constant across the H-mode transition. We will need further analysis to confirm this observation. At high power in H-mode, J antenna struggled and requires further experimental time to determine if this is a limitation or conditioning issue. |
| Physics Operator Summaries |
| Entered: Jul 26 2005 04:24:08:400PM |
| Author: Jim Irby |
| The machine ran extremely well today. We had 31 plasmas, 1 dud, and
no fizzles. The only tweaks required were in the prefill gas levels that varied somewhat early in the run and then stabilized, so that even gas adjustments became rare. On the other hand, we had a persistent MARFE from 300 to 500 ms that was improved by slowing down the density rise, but not eliminated. The MARFE also became less pronounced as the run continued, possibly indicating dirty wall conditions. Several shots also had injections or thrashes early in the shot (120 ms) that almost resulted in the loss of the plasma. Score: duds 24 fizzles plasmas 01,02,03,04,05,06,07,08,09,10 11,12,13,14,15,16,17,18,19,20 21,22,23,25,26,27,28,29,30,31 32 |
| Session Leader Comments | |||
| Jul 25 2005 05:02:28:683PM | Steve Wukitch | Run Summary:
We finished the 3He scan and found the optimum puff is ~100-120 msec. From the break-in-slope analysis, the 3He fraction is ~5-7%. For concentrations less than this, the heating effectiveness was poorer compared to E antenna at similar power levels. Another observation is that -90 phasing produces the best plasma response in heating and neutrons. Heating phasing is similar but +90 phasing was significantly reduced. The trips in H-mode suggest the He fraction remains relatively constant across the H-mode transition. We will need further analysis to confirm this observation. At high power in H-mode, J antenna struggled and requires further experimental time to determine if this is a limitation or conditioning issue. | |
| Jul 25 2005 09:47:25:357AM | 1050725001 | Steve Wukitch | 001 Ip~0.7 MA, BT~3.5 T, nl04~0.8
J: [0.7,1.2] sec Result: plasma J: no J3 - problem holding high voltage operation was set to normal - need independent mode next shot: lower field to 3.3 T set J to independent mode |
| Jul 25 2005 10:08:18:480AM | 1050725002 | Steve Wukitch | 002 Ip~0.7 MA, BT~3.3 T, nl04~0.8
J: 1.5 MW [0.7,1.2] sec Result: plasma J: no J3 - problem holding high voltage J4 ran |
| Jul 25 2005 10:08:08:683AM | 1050725003 | Steve Wukitch | 003 Ip~0.7 MA, BT~3.3 T, nl04~0.8
J: 1.5 MW [0.7,1.2] sec Result: plasma J: no J3 - problem holding high voltage J4 ran next shot: trouble shoot #3 and switch to 5.2 T discharges for D(3He) & D(H) |
| Jul 25 2005 10:58:45:730AM | 1050725004 | Steve Wukitch | 004 Ip~1 MA, BT~5.2 T, nl04~0.8
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.2 MW ramp [0.6,1] sec Result: plasma - early marfe E: max faults J: ran |
| Jul 25 2005 11:14:45:763AM | 1050725005 | Steve Wukitch | 005 Ip~1 MA, BT~5.2 T, nl04~0.8, He3 puff at 0.3 sec, 60 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.2 MW ramp [0.6,1] sec Result: plasma - early marfe E: ran J: ran note: no FRCECE |
| Jul 25 2005 11:26:38:637AM | 1050725006 | Steve Wukitch | 006 Ip~1 MA, BT~5.2 T, nl04~0.8, He3 puff at 0.3 sec, 60 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.2 MW ramp [0.6,1] sec Result: plasma E: ran 1 fault J: ran E clearly heats better than J next shot: increase puff to 70 msec, lower field to 5.1 T |
| Jul 25 2005 11:52:54:780AM | 1050725008 | Steve Wukitch | 008 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 80 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma - marfe is back E: ran 1 fault J: ran |
| Jul 25 2005 11:54:47:577AM | 1050725009 | Steve Wukitch | 009 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 80 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran next shot: increase puff to 90 msec |
| Jul 25 2005 12:09:44:560PM | 1050725010 | Steve Wukitch | 010 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 90 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran next shot: increase puff to 100 msec |
| Jul 25 2005 12:18:41:653PM | 1050725011 | Steve Wukitch | 011 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran next shot: increase puff to 120 msec |
| Jul 25 2005 12:37:18:060PM | 1050725012 | Steve Wukitch | 012 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 120 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran 3 programmed faults next shot: repeat without notches |
| Jul 25 2005 12:45:08:747PM | 1050725013 | Steve Wukitch | 013 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 120 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran next shot: increase puff to 140 msec |
| Jul 25 2005 01:43:55:357PM | 1050725014 | Steve Wukitch | 014 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 140 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran 2 programmed faults next shot: raise field to 5.2 T |
| Jul 25 2005 01:44:06:810PM | 1050725015 | Steve Wukitch | 015 Ip~1 MA, BT~5.2 T, nl04~0.8, He3 puff at 0.3 sec, 140 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran J: ran 2 programmed faults note: 9-10% next shot: 5.3 T and 200 msec puff |
| Jul 25 2005 01:44:22:060PM | 1050725016 | Steve Wukitch | 016 Ip~1 MA, BT~5.2 T, nl04~0.8, He3 puff at 0.3 sec, 200 msec
E: 1.2 MW ramp [1.1,1.5] sec J4: 1.4 MW ramp [0.6,1] sec Result: plasma E: ran 1 fault J: ran 2 programmed faults, 1 fault note: 13% 3He fraction next shot: 5.1 T and 100 msec puff restart J3 - set for current drive phasing restart D - 300 kW level |
| Jul 25 2005 02:08:21:247PM | 1050725017 | Steve Wukitch | 017 Ip~1 MA, BT~5.2 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 230 deg D: 0.3 MW [1.1,1.5] sec E: 1.2 MW ramp [1.1,1.5] sec J: 1.5 MW ramp [0.6,1] sec Result: plasma D: max faults E: ran J: ran JVX raw is 2.4 V better response to J - is it phase dependent? |
| Jul 25 2005 02:16:29:780PM | 1050725019 | Steve Wukitch | 019 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg D: 0.3 MW [1.1,1.5] sec E: 1.2 MW ramp [1.1,1.5] sec J: 1.5 MW ramp [0.6,1] sec Result: plasma D: max faults E: ran J: ran |
| Jul 25 2005 03:29:21:090PM | 1050725020 | Steve Wukitch | 020 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 230 deg corresponds to heating-phasing D: 0.3 MW [1.1,1.5] sec E: 1.2 MW ramp [1.1,1.5] sec J: 1.5 MW ramp [0.6,1] sec Result: plasma D: max faults E: ran J: ran (JVX ~+2.7 V => -90deg ctr-Ip) next shot: set phase to 50 deg |
| Jul 25 2005 03:18:18:277PM | 1050725021 | Steve Wukitch | 021 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 50 deg correpsonds to +90deg (co-plasma current direction) D: 0.3 MW [1.1,1.5] sec E: 1.2 MW ramp [1.1,1.5] sec J: 1.5 MW ramp [0.6,1] sec Result: plasma D: max faults E: ran J: ran (JVX ~-2.7 V => +90deg co-Ip) next shot: compare J total with J4 |
| Jul 25 2005 02:44:00:217PM | 1050725022 | Steve Wukitch | 022 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing J: 1.5 MW ramp [0.6,1] sec J4: 1.5 MW ramp [1.1,1.5] sec Result: plasma - not entirely clear result J: ran next shot: switch order |
| Jul 25 2005 03:10:44:933PM | 1050725023 | Steve Wukitch | 023 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing J4: 1.5 MW ramp [0.6,1] sec J: 1.5 MW ramp [1.1,1.5] sec Result: plasma J: ran note: heating is wavenumber independent but directionally dependent |
| Jul 25 2005 03:16:57:963PM | 1050725024 | Steve Wukitch | dud |
| Jul 25 2005 03:38:01:120PM | 1050725025 | Steve Wukitch | 025 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 2 MW [0.7,1.3] sec Result: plasma E: ran 1 fault J: ran max faults note: good shot for deposition in H-mode next: improve match |
| Jul 25 2005 03:59:27:620PM | 1050725027 | Steve Wukitch | 027 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 2 MW [0.7,1.3] sec Result: plasma E: ran 3 faults J: ran max faults next: disable phase balance fault for this phasing |
| Jul 25 2005 04:45:20:650PM | 1050725028 | Steve Wukitch |
028 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 2 MW [0.7,1.3] sec Result: plasma E: ran 5 faults J: ran max faults next: disable phase balance fault for this phasing |
| Jul 25 2005 04:45:31:980PM | 1050725029 | Steve Wukitch | 029 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 2 MW [0.7,1.3] sec Result: plasma E: ran multiple faults J: ran max faults |
| Jul 25 2005 04:45:49:650PM | 1050725030 | Steve Wukitch | 030 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 1.7 MW [0.7,1.3] sec Result: plasma E: ran multiple faults J: ran max faults |
| Jul 25 2005 04:47:52:557PM | 1050725031 | Steve Wukitch | 031 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 1.4 MW [0.7,1.3] sec Result: plasma E: ran multiple faults J: ran 3 faults where did RF cell data go? |
| Jul 25 2005 05:02:16:853PM | 1050725032 | Steve Wukitch | 032 Ip~1 MA, BT~5.1 T, nl04~0.8, He3 puff at 0.3 sec, 100 msec
phase set to 315 deg corresponds to heating-phasing E: 1 MW [0.7,1.3] sec J: 1.6 MW [0.7,1.3] sec Result: plasma E: ran 3 faults J: ran multiple faults |
| Physics Operator Comments | |||
| Jul 25 2005 07:42:12:263AM | Jim Irby | Physop Plan 1050725
MP 390 D(He3) Minority Heating Evaluation at 50 MHz SL: Wukitch PO: Irby Engineering setup as on 1050718001 A-coil configuration: normal [+Dtop -Dbot -Jtop +Jbot] and enabled. Gas Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid disabled (PG1) leave B-side upper 15 psi He3, disabled (PG2) fill B-main with 40 psi D2 Hybrid enabled (PG3) Enable the following: ECE and VUV gate valves, Z-bolo shutters ICRF Setup: transmitters in run-on at 8:30 | |
| Jul 25 2005 09:15:24:857AM | Jim Irby | Loaded from 1050718004 --- 0.7 MA, 3.5T, SNL, D(H) heating at 50 MHz
loaded seg 1 of 1050722026 into seg 1 --- good startup from last Friday load/clean produced wire 14, seg 1 "probably not what you want" message which was fixed with a small tweak to IC-EF2L. have 23 ms of gas from PG4 prefill -- as on last shot last Friday activity before the start of the run: PCI gatevalves opened (pressure was 1.0e-8 Torr with gatevalves closed, pulsed up to high 10-7 scale when they were opened). because of manpower problems expected after the run, we took time to re-install the diborane bottle this morning delaying the run by at least 30 minutes | |
| Jul 25 2005 09:43:04:420AM | 1050725001 | Jim Irby | basepressure about 3e-8 Torr
plasma into rampdown neuts/hards up early |
| Jul 25 2005 10:01:55:590AM | 1050725002 | Jim Irby | increased pg3 prepuff to help reduce runaways
Drop Bt from 3.4 to 3.3T, programmed current from 91 to 87.828 kA plasma for 1.61 s --- a couple of h-modes --- no power from #3 breakdown early no early neuts and hards |
| Jul 25 2005 10:08:01:840AM | 1050725003 | Jim Irby | no DPCS changes
plasma into rampdown prefill creeping up |
| Jul 25 2005 11:04:43:043AM | 1050725004 | Jim Irby | loaded 1050718026 into seg 2 --- giving up on D(H)
reduced prefill by 2 ms enabled PG2 (helium 3) with 60 ms pulse starting at 300 ms enabled argon/neon (1psi/2psi) starting at 300 ms for 50 ms plasma into rampdown --- but big MARFE early |
| Jul 25 2005 11:10:24:030AM | 1050725005 | Jim Irby | slowed down density rise to help with MARFE
added back 1 ms to the prefill (now 22 ms) plasma into rampdown still have MARFE, but started later --- slow down density rise again for next shot |
| Jul 25 2005 11:21:02:560AM | 1050725006 | Jim Irby | slowed down density rise again
density for 1.57 s, probably LPI did us in |
| Jul 25 2005 11:31:53:217AM | 1050725007 | Jim Irby | Bt to 5.1 from 5.2 T
helium puff from 60 to 70 ms starting at 300 ms plasma into rampdown --- LPI fired with pellet arriving around 1.55 s startup looks okay --- MARFE is gone |
| Jul 25 2005 11:46:52:077AM | 1050725008 | Jim Irby | Helium puff to 80 ms starting at 300 ms
plasma into rampdown --- a little bit of Marfing |
| Jul 25 2005 12:03:43:530PM | 1050725009 | Jim Irby | reduced early density rise again
plasma into rampdown still have MARFE starting around 4.1 s though density is lower neuts/hards up |
| Jul 25 2005 12:08:46:730PM | 1050725010 | Jim Irby | Helium puff to 90 ms starting at 300 ms
plasma into rampdown still have MARFE |
| Jul 25 2005 12:30:11:967PM | 1050725011 | Jim Irby | Helium puff to 100 from 90 ms starting at 300 ms
plasma into rampdown |
| Jul 25 2005 12:41:20:013PM | 1050725012 | Jim Irby | helium puff from 100 to 120 ms starting at 300 ms
plasma for 1.56 s |
| Jul 25 2005 12:44:43:637PM | 1050725013 | Jim Irby | No DPCS changes
plasma into rampdown |
| Jul 25 2005 01:03:06:793PM | 1050725014 | Jim Irby | helium 3 puff for 140 ms starting at 300 ms
plasma for 1.56 s but injections almost did us in at 0.133 s |
| Jul 25 2005 01:15:14:137PM | 1050725015 | Jim Irby | Bt back to 5.2 T (143.8 kA)
plasma into rampdown |
| Jul 25 2005 01:29:06:183PM | 1050725016 | Jim Irby | Bt to 5.3 T
helium puff for 200 ms starting at 300 ms plasma into rampdown --- MARFE a little better |
| Jul 25 2005 01:45:46:763PM | 1050725017 | Jim Irby | Bt to 5.1 T
Helium puff from 200 to 100 ms starting at 300 ms plasma into rampdown |
| Jul 25 2005 01:59:02:263PM | 1050725018 | Jim Irby | No DPCS changes
plasma into rampdown |
| Jul 25 2005 02:01:08:683PM | 1050725019 | Jim Irby | No DPCS changes
plasma into rampdown |
| Jul 25 2005 02:20:04:247PM | 1050725020 | Jim Irby | No
DPCS changes plasma into rampdown --- brief H-Mode |
| Jul 25 2005 02:29:23:340PM | 1050725021 | Jim Irby | no DPCS changes
plasma into rampdown |
| Jul 25 2005 02:55:57:887PM | 1050725022 | Jim Irby | No DPCS changes
good shot |
| Jul 25 2005 03:14:23:823PM | 1050725023 | Jim Irby | No DPCS changes --- 25 minute period for cell entry
good shot 10% drop in prefill level, but startup still pretty good; breakdown a little earlier injection at 0.13 s again stopped current rise briefly |
| Jul 25 2005 03:24:32:120PM | 1050725024 | Jim Irby | No DPCS changes
dud -- fields okay, gas a little low |
| Jul 25 2005 03:37:11:807PM | 1050725025 | Jim Irby | added 1 ms to prefill
good shot prefill still a little low |
| Jul 25 2005 03:54:31:540PM | 1050725026 | Jim Irby | increased prefill by 1 ms (24 ms)
good shot --- h-modes pressue up, breakdown 3 ms later |
| Jul 25 2005 04:05:06:650PM | 1050725027 | Jim Irby | No DPCS changes
good shot |
| Jul 25 2005 04:17:52:137PM | 1050725028 | Jim Irby | no DPCS changes
good shot |
| Jul 25 2005 04:30:03:200PM | 1050725029 | Jim Irby | No DPCS changes
good shot |
| Jul 25 2005 04:42:53:057PM | 1050725030 | Jim Irby | no DPCS changes
good shot TCI has large baseline offset |
| Jul 25 2005 04:55:31:290PM | 1050725031 | Jim Irby | No DPCS changes
good shot --- lots of h-modes |
| Jul 25 2005 05:05:54:340PM | 1050725032 | Jim Irby | No DPCS changes
good shot all done |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:28:50:420AM | Plasma | Ok | |
| 2 | 09:46:32:997AM | Plasma | Ok | |
| 3 | 10:00:27:933AM | Plasma | Ok | |
| 4 | 10:21:53:263AM | Plasma | Ok | |
| 5 | 10:57:10:573AM | Plasma | Ok | |
| 6 | 11:09:56:137AM | Plasma | Ok | |
| 7 | 11:22:39:387AM | Plasma | Ok | |
| 8 | 11:35:15:793AM | Plasma | Ok | |
| 9 | 11:48:21:573AM | Plasma | Ok | |
| 10 | 12:01:39:513PM | Plasma | Ok | |
| 11 | 12:14:20:247PM | Plasma | Ok | |
| 12 | 12:27:16:670PM | Plasma | Ok | |
| 13 | 12:39:52:870PM | Plasma | Ok | |
| 14 | 12:52:31:997PM | Plasma | Ok | |
| 15 | 01:05:13:230PM | Plasma | Ok | |
| 16 | 01:17:59:793PM | Plasma | Ok | |
| 17 | 01:30:24:200PM | Plasma | Ok | |
| 18 | 01:42:55:513PM | Plasma | Ok | |
| 19 | 01:56:21:810PM | Plasma | Ok | |
| 20 | 02:08:54:340PM | Plasma | Ok | |
| 21 | 02:21:37:530PM | Plasma | Ok | |
| 22 | 02:34:07:810PM | Plasma | Ok | |
| 23 | 03:02:37:667PM | Plasma | Ok | |
| 24 | 03:15:05:637PM | Plasma | Ok | |
| 25 | 03:27:40:620PM | Plasma | Ok | |
| 26 | 03:40:11:790PM | Plasma | Ok | |
| 27 | 03:53:11:743PM | Plasma | Ok | |
| 28 | 04:05:51:667PM | Plasma | Ok | |
| 29 | 04:18:16:917PM | Plasma | Ok | |
| 30 | 04:30:44:260PM | Plasma | Ok | |
| 31 | 04:43:31:137PM | Plasma | Ok | |
| 32 | 04:56:05:917PM | Plasma | Ok | |