Alcator C-Mod Run 1051129 Information

Back to runs

Miniproposals
Miniproposal:419
Date Filed: 4/8/2005
Title:Fiducial wall pumping measurements for comparing operating conditions
First Author:Bruce Lipschultz
Session Leader:Bruce Lipschultz (shots 1-33)

Operators
Session leader(s):Bruce Lipschultz
Physics operator(s):Steve Wolfe,Ian Hutchinson
Engineering operator(s):Bill Cochran,Bill Byford,Ed Fitzgerald

Engineering Operator Run Comment
MP#419 Wall pumping

Session Leader Plans
Entered: Nov 28 2005 05:56:37:517PM
Author: Bruce Lipschultz
SL plan for 1051129
Session Leader: B. Lipschultz

MP #419: 'Fiducial wall pumping measurements for comparing operating conditions'
Parts of this were attempted before. However, the results were muddled by the Ti in the machine and we decided they need to be repeated.

There are several goals for this run:

We are looking for 1 MA shots with densities just under nl04=1.e20. We need the shots not to disrupt through to current reaching close to zero. No RF. Gate valves closed after the first shot or two that go through.

1) We want to return to the standard shot of last run period and see if we can repeat the pumping. This will require several shots (The equilibrium used will be 1051118003). This will mean starting with nl04~0.5. When that is taken, move on to nl04=0.9. Finally, nl04=1.2. (6-8 shots including tuneup).

2) We will be seeing if the wall pumping saturates as well. So this will require at least 5 constant shots. Take this at nl04=1.0. (5 shots).

3) Vary the wetted area to see if that affects the pumping. We will start with LSN on the vertical target (step 1). Then move to slot (e.g. 1050620024), inner wall limited (no success previously). Finally to upper single null (shot 1051118022 for equilibrium). Three shots at each new magnetic equilibrium (12 shots).

4) We would also like to know if the pumping saturates with length of shots (fluence). This will require several shots at verious flattop periods varying from 0. (e.g. 1050805031), 0.5 (e.g. 1050805029), 1.0, 1.5, & 2.0 s (e.g. 1050805028) . The density should be down around 0.85 and the current 0.8 MA. Likely not time enough today.

Physics Operators Plans
Entered: Nov 28 2005 06:35:03:017PM
Author: Steve Wolfe
Physop plan and engineering setup for Tuesday, Nov 29, 2005

MP#419 Wall pumping
SL: Blip
PO: Wolfe,Hutch

ECDC overnight (if no conflict with other activities) and 60C bake. 
Run begins at 09:00 (lockup at 08:30) and ends at 17:00

Power systems as on 1051118003
A-coil in standard configuration (+Dtop -Dbot -Jtop +Jbot) and enabled
Fizzle delay on OH2's set to 300msec. 

Gas setup:
fill B-top 6psi D2 Hybrid Enabled (PG4)
fill B-side lower 1psi Argon+2psi Neon, Hybrid Disabled (PG1)
leave B-side Upper alone Hybrid DISABLED (PG2)
fill B-main 40psi D2 Hybrid Enabled (PG3)

Enable: ECE, VUV, Z-bolo shutter. Do not enable DNB 

TMP#2 gate valve should be closed for the day

After the first successful shot, we will want TMP#1 gate valve
closed in pulse and for five minutes after the shot for the remainder 
of the run. 

NO ICRF for this run. If desired, RF group can test the fix on FMIT#3 
HV interlock fault, but no RF into the machine.

Plan-
 See SL_PLAN for goals and reasons. 

Begin with 1051118003 (1MA, LSN, 5.2T), NL04 reduced to 0.5e20. May raise TF
to 5.4T if SL prefers.
Proceed to higher densities 0.9 and 1.2e20 

Take ~5 shots at constant NL04=1.0e20

Move strike point into slot (program similar to 1050620024). 

Change to inner wall limited discharge

Change to upper null, e.g. 1051118022 (I think this is already in 
seg3 of 1051118003)

If time permits (unlikely), vary Ip flattop duration with 
Ip=0.8MA, nl04=0.85e20


Session Leader Summaries
Entered: Nov 29 2005 05:58:34:140PM
Author: Bruce Lipschultz
SL summary for 1051129
Session Leader: B. Lipschultz

MP #419: 'Fiducial wall pumping measurements for comparing operating conditions'

The start of the day waqs difficult - primarily computer/CAMAC problems. Then things got going.

We covered a decent fraction of the MP today - primarily the pulselength and saturation question.

Saturation of pumping - shots 11-18 showed that the wall pumping decreasesd over 3-4 shots. This appears to be a combination of changes in amount puffed and gas remaining in the machine. When we did this previously, after the Ti problems last run preiod, the wall pumping seemed to hold more constant. But today we had more shots.

pulselength - The amount puffed certainly decreased with pulselength. However, the amount remaining did to such that the wall pumping did not vary very much. For example the gas injected varied from 30 to 20 tl as the pulselength was decreased. But the amount 'pumped' varied from ~ 8 to 5.5 tl in going from 1.5 to 0.5 current inversion time. It may be that current rise and rampdown are having a largeeer effect on pumping than anticipated.

Other thoughts
- We had a number of cases where we had poloidal detachment during rampdown. I am concerned that this may be affecting things. For example, shot 28 had a MARFE the entire shot. The density was higher than requested and the gas turned off. The wall pumping was 0 on that shot. So MARFEs and poloidal detachment tend to fuel the plasma from somewhere and it seems to be from the wall.

- Varying the equilibrium - particularly inner wall limited seems to have become more important to do.

- The amount pumped at low density is higher than what we have observed before. That is puzzling, particularly since the amount pumped at higher densities drops after repeated shots. This deserves further discussion.

shot gas inj gas remain diff Ip nl04 falttop inversion
2 12.5 5 7.5 1. .5 1.5
4 2.3 16.3 -14 1. .5 1.5 disrupted early
7 13.8 4.7 9 1. .5 1.5
8 12.4 5.3 7.1 1. .6 1.5
9 24.4 9.5 14.9 1. 0.82 1.5
11 29 15.5 4.5 1. 1.0 1.5
13 26.7 16 10.7 1. 1.0 1.5
15 27. 17.3 9.7 1. 1.0 1.5
16 25. 17.5 7.5 1. 1.0 1.5
17 25.3 18.0 7.3 1. 1.0 1.5
18 24.7 17.8 6.9 1. 1.0 1.5
19 31. 23.2 7.8 0.8 1.0 1.5
20 28. 20.3 7.7 0.8 1.0 1.5
21 30.9 22.5 8.4 0.8 1.0 1.5
23 22.6 17.1 5.5 0.8 0.8 0.5 disrupt @200 kA
24 19.6 14.4 5.1 0.8 0.8 0.5 disrupt @200 kA
25 19.1 14.0 5.1 0.8 0.8 0.5 disrupt @110 kA
26 25.5 19.2 6.3 0.8 1.0 1.0 disrupt @300 kA
27 26.4 19.8 6.6 0.8 1.0 1.0 disrupt @110 kA
28 17.3 17.3 0.0 0.8 1.25 1.0 MARFE the entire shot
29 26.9 19.0 7.9 0.8 1.0 1.0 disrupt @250 kA
30 26.7 18.8 7.9 1.0 1.0 1.5
31 24.3 25.5 -1.2 1.0 1.0 1.5 slot divertor 500 kA disruption
32 23.5 15.7 7.8 1.0 1.0 1.5 slot divertor
33 20.2 15.0 5.2 1.0 1.0 1.5 slot divertor

Physics Operator Summaries
Entered: Nov 29 2005 05:20:06:263PM
Author: Ian Hutchinson
Summary
_______

This run, with gate-valves closed after the shot, posed some interesting problems for initiation. The master initiation developed at the start of this campaign was reloaded 1051101023. This is known to be reliable at controlled fill pressure. However, because of the closed gate valves, the fill pressure rises of its own accord because of the outgassing. This is stronger at higher plasma density, of course.

It was found that this initiation cannot support more than about 0.06mtorr of fill without fizzling. We therefore had to pay attention to the outgassing and fill control. Fill puff was lowered in steps to 10ms. Then we were getting approximately half of the fill pressure from the base. The reason this was so high was that when the gate valve is closed at the start of init, the base pressure rises continuously to values on the e-5 scale. This problem was helped by delaying the gate valve closing by 30 into init. We still got one fizzle (22) at 0.048mtorr fill, but at lower pressure things seemed generally more satisfactory and down to .035mtorr was observed to work fine.

The aims of the MP were mostly addressed. There were (as expected by me) problems with ramp-down of short shots, in that they quite often had smallish disruptions before reaching zero current.
Scorecard
_________

  Shot,Duration(s),Ipmax(MA),Result  Shot,Duration(s),Ipmax,Result
  |   01   0.000   0.024   Dud     |    2   No Ip                   |
  |   03   0.000   0.002   Dud     |   04   0.359   0.826   Plasma  |
  |   05   0.000   0.025   Dud     |   06   0.000   0.028   Fizzle  |
  |   07   1.972   1.015   Plasma  |   08   1.971   1.010   Plasma  |
  |   09   1.964   1.005   Plasma  |   10   0.000   0.024   Fizzle  |
  |   11   1.944   1.002   Plasma  |   12   0.000   0.024   Fizzle  |
  |   13   1.927   1.001   Plasma  |   14   0.000   0.023   Fizzle  |
  |   15   1.928   1.002   Plasma  |   16   1.923   1.001   Plasma  |
  |   17   1.921   1.000   Plasma  |   18   1.932   1.001   Plasma  |
  |   19   1.888   0.811   Plasma  |   20   1.911   0.815   Plasma  |
  |   21   1.900   0.819   Plasma  |   22   0.000   0.025   Fizzle  |
  |   23   0.843   0.809   Plasma  |   24   0.868   0.802   Plasma  |
  |   25   0.996   0.797   Plasma  |   26   1.345   0.807   Plasma  |
  |   27   1.417   0.804   Plasma  |   28   1.394   0.792   Plasma  |
  |   29   1.419   0.806   Plasma  |   30   1.934   1.001   Plasma  |
  |   31   1.746   1.048   Plasma  |   32   1.953   1.054   Plasma  |
  |   33   1.955   1.057   Plasma 

Date 1051129:  33 shots.  24 plasmas.   5 fizzles.   3 duds.   1 System Error.
        (Plasma = Ip gt 50.0 kA   Dud = H_alpha lt  0.40 V)
Total plasma duration: 39.41 s (exceeding -100 kA)

Session Leader Comments
Nov 29 2005 09:09:06:210AM1051129001Bruce Lipschultzdud
Nov 29 2005 10:04:12:333AM1051129002Bruce LipschultzShot went - sort of. No magnetics (after a very long delay for computer problems). Steve says that we got 1 MA. The density appears wobbly just below nl04=5e20.

Gas injected - 12.5 tl
Gas remaining - ~ 5 tl
Wall pumping 7.5 tl
Nov 29 2005 10:05:20:303AM1051129003Bruce Lipschultztest shot for data system
Nov 29 2005 10:36:44:663AM1051129004Bruce Lipschultzdisrupted early - not useful.

gas injected - 2.3 tl
gas remaining - 16.3 tl
outgassed 14 tl
Nov 29 2005 10:40:10:960AM1051129005Bruce Lipschultzdud :-(
Nov 29 2005 10:59:14:943AM1051129006Bruce Lipschultzfizzle :-(
Nov 29 2005 11:20:36:490AM1051129007Bruce LipschultzYes! a 1 MA plasma. nl04 = 0.5e20
gaps a bit small. Will increase.

gas injected - 13.8 tl
gas remaining - 4.6 - 4.9 tl
wall pumping - 9 tl
Nov 29 2005 11:33:44:287AM1051129008Bruce Lipschultz1 MA plasma. nl04 = 0.6e20
gaps ~ 1.5 cm both sides.

gas injected - 12.4 tl
gas remaining - 5.3 tl
wall pumping - 7.1 tl

In the previous run period this density led to lower wall pumping. A bit of a mystery. Move on to higher densities.
Nov 29 2005 11:46:58:570AM1051129009Bruce Lipschultz1 MA plasma. nl04 = 0.82e20

gas injected - 24.4 tl
gas remaining - 9.5 tl
wall pumping - 14.9 tl

Nov 29 2005 11:56:25:070AM1051129010Bruce Lipschultzfizzle
Nov 29 2005 12:12:50:320PM1051129011Bruce Lipschultz1 MA plasma. nl04 = 1.e20
Some number of small H-modes

gas injected - 29. tl
gas remaining - 15.5 tl
wall pumping - 14.5 tl

repeat the shot to see if the wall pumping holds constant. We will allow the Ne/Ar mixture in for the next shot.
Nov 29 2005 12:15:41:380PM1051129012Bruce Lipschultzfizzle
Nov 29 2005 12:39:18:537PM1051129013Bruce Lipschultz1 MA, nl04=1.e20 repeat to see if wall pumping changes.
More small H-modes

Gas injected - 26.7 tl
gas remaining - 16 tl
wall pumping - 10.7 tl

less than the previous shot!
Nov 29 2005 12:53:49:210PM1051129014Bruce Lipschultzfizzle
Nov 29 2005 01:08:42:680PM1051129015Bruce Lipschultz1 MA, nl04=1.0 repeat.

gas injected - 27 tl
gas remaining - 17.3tl
wall pumping - 9.7 tl

slightly less pumping
Nov 29 2005 01:26:08:787PM1051129016Bruce Lipschultz1 MA, nl04=1.0 repeat.
Dithering into H-modes....

gas injected - 25 tl
gas remaining - 17.5tl
wall pumping - 7.5 tl

slightly less pumping. Next shot we are going to reduce the time the gate valcve is closed before the shot in hopes of reducing the timebetween shots (waiting for the pressure in the machine to coem down to the level needed).
Nov 29 2005 04:23:39:890PM1051129017Bruce Lipschultz1 MA, nl04=1.0 repeat.
Dithering into H-modes....

gas injected - 25.3 tl
gas remaining - 18.0 tl
wall pumping - 7.3 tl

Nov 29 2005 01:52:50:803PM1051129018Bruce Lipschultz1 MA, nl04=1.0 repeat.
Dithering into H-modes....

gas injected - 24.7 tl
gas remaining - 17.8tl
wall pumping - 6.9 tl

slightly less pumping. Next shot lower current.
Nov 29 2005 02:07:54:600PM1051129019Bruce Lipschultz0.8 MA, nl04=1.0 to set up for different length shots

gas injected - 31.0 tl
gas remaining - 23.2 tl
wall pumping - 7.8 tl


Nov 29 2005 02:31:22:100PM1051129020Bruce Lipschultz0.8 MA, nl04=1.0 second shot.

gas injected - 28.0 tl
gas remaining - 20.3 tl
wall pumping - 7.7 tl

same as last shot.


Nov 29 2005 02:36:42:977PM1051129021Bruce Lipschultz0.8 MA, nl04=1.0 second shot.

gas injected - 30.9 tl
gas remaining - 22.5 tl
wall pumping - 8.4 tl

similar to last shot.


Nov 29 2005 02:37:48:520PM1051129022Bruce Lipschultzfizzle.
Nov 29 2005 03:03:33:630PM1051129023Bruce Lipschultzshort shot (0.5 s at rampdown. nl04=1.0, Ip=0.8 MA.
Disruption at 200 kA following a 'sharkfin'.

gas injected - 22.6 tl
gas remaining - 17.1 tl
wall pumping - 5.5 tl

try again to get rid of the disruption.
Nov 29 2005 03:17:57:710PM1051129024Bruce Lipschultzshort shot (0.5 s at rampdown. nl04=1.0, Ip=0.8 MA.
Disruption at 200 kA following a 'sharkfin'.

gas injected - 19.6 tl
gas remaining - 14.4 tl
wall pumping - 5.1 tl

try again to get rid of the disruption.
Nov 29 2005 03:30:54:083PM1051129025Bruce Lipschultzshort shot (0.5 s at rampdown. nl04=1.0, Ip=0.8 MA.
Disruption at 110 kA.

gas injected - 19.1 tl
gas remaining - 14.0 tl
wall pumping - 5.1 tl

move to longer shots next.
Nov 29 2005 03:43:22:867PM1051129026Bruce Lipschultzshort shot (1.0 s at rampdown. nl04=1.0, Ip=0.8 MA.
Disruption at 325 kA.

gas injected - 25.5 tl
gas remaining - 19.2 tl
wall pumping - 6.3 tl

try to get rid of the disruption.
Nov 29 2005 04:03:06:877PM1051129027Bruce Lipschultzshort shot (1.0 s at rampdown. nl04=1.0, Ip=0.8 MA.
dsirupted at 110 kA
gas injected - 26.4 tl
gas remaining - 19.8 tl
wall pumping - 6.6 tl

try to get rid of the disruption.
Nov 29 2005 04:08:59:153PM1051129028Bruce Lipschultzshort shot (1.0 s at rampdown. nl04=1.25, Ip=0.8 MA.
This one had a problem with density early on. MARFE or something led to higher densities and the gas valve shut.

gas injected - 17.3 tl
gas remaining - 17.3 tl
wall pumping - 0. tl

try to get rid of the disruption and the MARFE.
Nov 29 2005 04:24:56:360PM1051129029Bruce Lipschultz0.8 MA, nl04=1.0 repeat.
sharkfin as before, disrupt at 250 kA.

gas injected - 26.9 tl
gas remaining - 19.0 tl
wall pumping - 7.9 tl

Return to 1 MA
Nov 29 2005 04:37:56:983PM1051129030Bruce Lipschultz1.0 MA, nl04 =1.0e20
rampdown to 90 kA, sharkfin.

start of changes in equilibrium

gas injected - 26.7 tl
gas remaining - 18.8 tl
wall pumping - 7.9 tl
Nov 29 2005 04:50:32:530PM1051129031Bruce Lipschultz1.0 MA, nl04 =1.0e20
switch to slot divertor
disruption at 550 kA

gas injected - 24.3 tl
gas remaining - 25.5 tl
wall pumping - -1.2 tl
Nov 29 2005 05:03:35:047PM1051129032Bruce Lipschultz1.0 MA, nl04 =1.0e20
slot divertor
H-modes (Ar and Ne on the last shot. turned off here)

gas injected - 23.5 tl
gas remaining - 15.7 tl
wall pumping - 7.8 tl


Nov 29 2005 05:19:13:530PM1051129033Bruce Lipschultz1.0 MA, nl04 =1.0e20
slot divertor
H-modes

gas injected - 20.2 tl
gas remaining - 15.0 tl
wall pumping - 5.2 tl


Physics Operator Comments
Nov 29 2005 07:46:21:193AMSteve Wolfe
Setting up for today's blip run (MP419)
Slightly weird behavior from PCS: edit wire
screen is coming up iconized. X may have gotten
confused because my scopes were popping up at the same time.
Blow away PCS and restart it. 
Seems ok now. 
Notes on current state of startup segment (from 1051123):
  RCUR offset at 1500a-m
  Br0=-1e-4
  IC_ef4u=-1350
  pg4=29msec
  oh1_volt at 200V from 0.003sec
Nov 29 2005 10:01:36:333AM1051129001Steve Wolfe
Shot#1: Contrary to what it says in the run plan,
go ahead and close gate valves during pulse for 
first shot. I'll leave pg4 at 29msec and see what 
we get. Probably need to reduce it. 

Dud. Somewhat of a surprise. 
Bz looks very negative, about -7mT before
t=0, despite the fact that I 
raised it 10A from last week. Br maybe a little
higher than normal, but not too bad. Pressure
at .065mTorr, a bit higher than last week, as 
expected. I think the problem is probably the fields.
OH2u coax looks ok, ends up below 2uOhm. I think I can 
afford a few failed startups before we start getting 
warnings. 

next shot: ef4 to -1325, br0 more negative

Nov 29 2005 10:01:06:100AM1051129002Steve Wolfe
Shot#2:  ef4 from -1340 to -1325,
br0 from 0 to -.0003
Leave gas and oh voltage where they were and try again
Long delay while Tom clears a problem with an LH store action. 
I have set the .LH node /noinclude for shot 2 and following.

Plasma full length. Breakdown a little late (9msec)
No magnetics signals this time. Looks like we had a lot 
of runaways, but they seem to develop late. No density 
trace yet, because it waits for the current, but I think
the density was very low. Rick ran it manually; it is between 
4 and 5e19 and has some oscillations, also seen on the
halpha

Magnetics data is toast. I'll have to reboot pcdaqmhd1 in the cell
next shot: no changes. 


Nov 29 2005 10:06:29:320AM1051129003Steve Wolfe
Shot#3: Take a no power shot at twf's request/suggestion
after rebooting pcdaqmhd1.
Ian is back and I'm logging out. 
 


Nov 29 2005 11:38:30:070AM1051129004Ian HutchinsonDisrupts at .35s. Not completely clear why, but density is low. Might be a
locked mode at about 3.2s, certainly there is a very resistive event.

Add some gas in segment 2 early.
Nov 29 2005 11:38:58:100AM1051129005Ian HutchinsonDud.

Remove -.3mT Br offset.
Load OH1V from 1050525002.
Nov 29 2005 11:39:57:710AM1051129006Ian HutchinsonFizzle.

Load segment 1 from 1051101023. There's a problem with the wire name changes.
Reload segment 1 from shot 6. OK. Reload segment 1 from 1051101023. It works
this time!!!
Nov 29 2005 11:40:30:210AM1051129007Ian HutchinsonPlasma to rampdown. Gaps are 1.25cm, and 1cm inner outer.

Add PG3 Voltage at .1s.
Set nl04 to .6 throughout.
Blip calls for 1.5,1.5cm gaps. This needs 2mm increase in clearin, and
1 mm reduction in rcur. Done. Load.
Nov 29 2005 11:41:05:007AM1051129008Ian HutchinsonPlasma to rampdown.

nl04 maybe to .85e20. Yes. Loaded.
Nov 29 2005 11:49:02:537AM1051129009Ian HutchinsonPlasma to rampdown.

nl04 to 1.e20 maybe. Yes. Load
Nov 29 2005 12:29:36:740PM1051129010Ian HutchinsonFizzle. Actual breakdown pressure has risen from .05 to .07 because of the residual gas.

Lower fill puff to 18ms from 21ms. (Trouble is that this fizzle will cause the fill to be lower on its own.)
Nov 29 2005 12:15:37:507PM1051129011Ian HutchinsonPlasma.

Set Ar/Ne puff to 30ms (from 50) enable for next shot. Load.
Nov 29 2005 12:28:30:240PM1051129012Ian HutchinsonFizzle. Actual fill .065. Started init at 2.5e6. Seems too early.

EF4 to -1320A from -1325. Tweak to hope that we could avoid the fizzles caused by high base pressure. Was about 1.4e6 at init start.
Nov 29 2005 12:55:18:820PM1051129013Ian HutchinsonPlasma to rampdown.

Reduce fill puff to 16ms. Enter init at 2.5e-6. 1.13-5 entering pulse.
Nov 29 2005 12:55:50:163PM1051129014Ian HutchinsonFizzle. Enter init at 2.5e-6. 1.13-5 entering pulse. 0.06mtorr at breakdown.
Plainly it does not like having the base pressure so high. Apparently there
is only one pump running at the moment.

No pcs changes. Disable VUV gate valve.
Nov 29 2005 01:12:10:693PM1051129015Ian HutchinsonPlasma.
Was 1.2e-6 entering init. entering pulse: 5.8e-6.

Lower fill puff to 14ms.
Wait for base pressure to reach 2.0e6 before init (14 min)
Nov 29 2005 01:26:09:053PM1051129016Ian HutchinsonPlasma to rampdown.
Pressure at pulse. 9.5e6 at pulse. 0.053mtorr total fill. Looks as if it only just went.

Lower fill puff to 12ms. PLC change to make the gate valve close 30seconds later.
Since the total of init and check is roughly 120sec, we reduce the pressure increase by about 25%. We will allow ourselves a higher level at enter init correspondingly. 2.3e-6, time 12min20s.
Nov 29 2005 01:33:50:490PM1051129016Ian HutchinsonPlasma to rampdown.
Pressure at pulse. 9.5e6 at pulse. 0.053mtorr total fill. Looks as if it only just went.

Lower fill puff to 12ms. PLC change to make the gate valve close 30seconds later.
Since the total of init and check is roughly 120sec, we reduce the pressure increase by about 25%. We will allow ourselves a higher level at enter init correspondingly. 2.3e-6, time 12min20s.
Nov 29 2005 01:39:30:897PM1051129017Ian HutchinsonPlasma to rampdown.
Got Pressure at check: 6.2e-6. Pressure at pulse: 9.5e-6. Fill 0.048mtorr.

Fill puff to 10ms. Go to init at 2.6e-6, 11min.
Nov 29 2005 01:52:57:790PM1051129018Ian HutchinsonPlasma.
Got: Pulse at 1.e-5. 0.045mtorr.

Lower Ip to 1MA. Go to init at 2.8e-6, 10:15min.
Nov 29 2005 02:07:05:727PM1051129019Ian HutchinsonPlasma.
Got Pulse at 1.1e-5. Fill 0.049mtorr.

Move Rcur in 1mm. Adjust the rxl ramp to help keep the strikepoint lower.
Go to init at 2.7e-6, 11min.
Nov 29 2005 02:24:23:630PM1051129020Ian HutchinsonPlasma.
Got 1.1e-5 at pulse. Fill 0.047mtorr.

Tweak rxl in more at the end of the shot. Init at 2.3, 13m because of cooling delay.
Nov 29 2005 02:37:43:320PM1051129021Ian HutchinsonPlasma.
Got 9.3e-6 at pulse. Fill 0.043mtorr.

Shorten shot to rampdown at 0.5s, using all Ps but no V-changes in segment 3.
Forgot to switch segments.
Enter init at 2.7e-6. Pulse at 1.1e-5.
Nov 29 2005 02:58:22:490PM1051129022Ian HutchinsonFizzle. Fill 0.048 can't be blamed on completely on fill pressure.

Switch segments to the short shot.
Nov 29 2005 03:02:54:193PM1051129023Ian HutchinsonPlasma flat-top only to 0.5s. Small terminating disruption. Fill 0.036mtorr.

Reduce the rcur swing inward. Raise nl04 earlier to make the gas puff earlier.
Ramp Bt down earlier.
Nov 29 2005 03:22:30:350PM1051129024Ian HutchinsonPlasma.
Got Pulse at 9.1e-6


Similar ramp-down disruption. Seems to be caused by OH1 going to zero and sticking at cross-over. This causes a wild increase in clearin.
Try ramping down slower.
Nov 29 2005 03:31:24:727PM1051129025Ian HutchinsonPlasma disrupts at 1s, 100kA. Bruce says good enough.

Program end of flattop at 1s. Enter init at 2.3e-6.
Nov 29 2005 03:53:08:350PM1051129026Ian HutchinsonPlasma. Disrupts at 300kA. I forgot to lengthen the Bt pulse so it began
to ramp down early.
Got pulse pressure: 9.5e-6. 0.043mtorr.

Delay Bt rampdown.
Nov 29 2005 03:59:46:770PM1051129027Ian HutchinsonPlasma disrupts at about 100kA.


Make nl04 rampdown earlier. Slow Ip ramp down. Adjust other aspects of ramp down.

Nov 29 2005 04:15:00:157PM1051129028Ian HutchinsonPlasma. Disrupts at 320kA. But also this shot had radiative events early which look like marfes or similar.

Delay the ramp up of nl04 to 1.e20 at .3s.
Nov 29 2005 04:32:21:030PM1051129029Ian HutchinsonPlasma. Disrupts at about 300kA.

Load from shot 18. Load.
Nov 29 2005 04:38:31:670PM1051129030Ian HutchinsonPlasma.

Load segment 2 from 1050620024.
Call all controllers.

Nov 29 2005 04:50:20:937PM1051129031Ian HutchinsonPlasma.


Slow EF4 inversion ramp. Disable Ar/Ne pulse which was large.
Nov 29 2005 05:01:00:937PM1051129032Ian HutchinsonPlasma. Ramped down. Got many ohmic H-modes.

Slow EF4 rampdown some more.
Nov 29 2005 05:18:40:470PM1051129033Ian HutchinsonPlasma. Very similar.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:05:22:587AMPlasmaOk
209:40:11:537AMPlasmaOk
310:03:46:380AMTestOkNo power data system test shot
410:18:06:397AMPlasmaBadOH1 Type 1 Flt
510:36:49:897AMPlasmaOk
610:49:37:710AMPlasmaOk
711:07:13:553AMPlasmaOk
811:20:31:413AMPlasmaOk
911:34:10:693AMPlasmaOk
1011:47:36:570AMPlasmaOk
1112:00:17:303PMPlasmaOk
1212:13:50:537PMPlasmaOk
1312:26:20:413PMPlasmaOk
1412:40:42:037PMPlasmaOk
1512:55:25:473PMPlasmaOk
1601:11:58:257PMPlasmaOk
1701:26:42:820PMPlasmaOk
1801:40:37:770PMPlasmaOk
1901:53:19:617PMPlasmaOk
2002:06:57:083PMPlasmaOk
2102:22:36:147PMPlasmaOk
2202:35:50:973PMPlasmaOk
2302:48:19:240PMPlasmaOk
2403:02:10:180PMPlasmaOk
2503:17:20:880PMPlasmaOk
2603:30:44:257PMPlasmaOk
2703:43:24:083PMPlasmaOk
2803:56:19:913PMPlasmaOk
2904:11:29:043PMTestOk
3004:24:21:843PMTestOk
3104:37:01:483PMTestOk
3204:50:56:030PMTestOk
3305:03:30:123PMTestOk