| Session leader(s): | John Rice |
| Physics operator(s): | Bill Rowan |
| Engineering operator(s): | Bill Cochran,Ed Fitzgerald |
| Engineering Operator Run Comment |
| MP#415 Rotation and thresholds |
| Session Leader Plans |
| Entered: May 23 2006 11:39:38:813AM |
| Author: John Rice |
| MP 415 calls for investigation of the H-mode power threshold in both USN and LSN with reversed plasma current and toroidal field. This will be done first at 0.8 MA with nl04 = 1. This will augment previous studies with normal field and current. The important diagnostics are ETS and HIREX-Jr. The first item of business is to determine a suitable USN discharge without the X-point in the ETS field of view. The ICRF power will then be ramped to get an estimate on the power threshold, then the exact value will be determined shot-to-shot varying the steady power level. The same procedure will then be used for a similar discharge with LSN, the 'unfavorable' drift direction. If time permits, this will be repeated at 1.0 MA. Boronization between shots may be required. |
| Physics Operators Plans |
| Entered: May 22 2006 02:44:04:617PM |
| Author: Bill Rowan |
| Engineering setup for Tuesday. 23 May 2006
MP#415 Rotation and thresholds SL: Rice PO: Rowan Overnight ECDC in deuterium; bake at 60 C The run will start at 09:00 and end at 17:00. Power systems as on: 1060519016, USN A-coil configuration: normal [-Dtop +Dbot +Jtop -Jbot] and enabled. Gas Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar + 2 psi Ne Hybrid enabled (PG1) leave B-side upper as is Hybrid DISABLED (PG2) fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3) leave NINJA as is disabled Enable the following gate valves and shutters, assuming no vacuum problems: ECE, VUV, Z-bolo shutters ------------------------------------------------------------------------------- ICRF setup: Transmitters #3 and #4 in run-on by 7:30, #1 and #2 in run-on by 8:30 (The ICRF group will vacuum-condition J-antenna before the run) ------------------------------------------------------------------------------- |
| Session Leader Summaries |
| Entered: May 23 2006 03:07:52:150PM |
| Author: John Rice |
| Session Leader Run Summary for 1060523 MP415 H-mode Power Threshold in USN and LSN with Reversed Current/Field The run got to a late start (2 hour delay) due to a power supply problem, then was plagued at the begining by a faulty pulsed gas valve (shots 1-6). Some shape development was performed (shots 7-13) for USN, to move the X-point out of the ETS view. The H-mode power threshold was very near 1.0 MW of ICRF in an un-boronized machine. Shot 14, the last of the day, was LSN with no H-mode at 2.3 MW. The run ended due to an alternator problem. |
| Physics Operator Summaries |
| Entered: May 23 2006 03:19:29:733PM |
| Author: Bill Rowan |
| The beginning of the run was delayed for two hours due to failure of a breaker in the TMX cabinets.
At the beginning of the run, piezo-electric gas valve PG3 failed to open to fuel the plasma. The valve was forced open by manually applying a voltage directly to it. This brought it back to life beginning with shot 007. Shots 007 through 013 were USN. We started from shot 1060519016 and modified it to better agree with the (flipped) shape of the LSN discharge 1060519008. Only one shot was obtained in LSN (1060519014) before an alternator fault ended the run. Score card plasmas 11 001, 002,003,007,008,009,010,011,012,013,014 gas tests 3 004,005,006 fizzles 0 duds 0 total 14 |
| Session Leader Comments | |||
| May 23 2006 11:40:28:940AM | 1060523001 | John Rice | no gas, but plenty of hard x-rays |
| May 23 2006 11:42:18:750AM | 1060523002 | John Rice | no gas, but plenty of hard x-rays |
| May 23 2006 11:44:34:453AM | 1060523003 | John Rice | disrupted early, 0.31 s |
| May 23 2006 01:37:10:673PM | 1060523004 | John Rice | test |
| May 23 2006 01:37:19:673PM | 1060523005 | John Rice | test |
| May 23 2006 01:37:26:140PM | 1060523006 | John Rice | test |
| May 23 2006 01:37:44:487PM | 1060523007 | John Rice | plasma, with ICRF ramp |
| May 23 2006 01:38:05:940PM | 1060523008 | John Rice | strange Ip and ne traces |
| May 23 2006 01:38:26:157PM | 1060523009 | John Rice | good plasma, ICRF ramp, strange H-mode |
| May 23 2006 01:48:27:797PM | 1060523010 | John Rice | good plasma, ICRF ramp, H-mode |
| May 23 2006 02:02:22:220PM | 1060523011 | John Rice | good plasma, ICRF ramp, H-mode near 1.0 MW |
| May 23 2006 02:14:08:220PM | 1060523012 | John Rice | good plasma, ICRF steady near 1.0 MW. H-mode? |
| May 23 2006 02:24:10:313PM | 1060523013 | John Rice | good plasma, ICRF steady near 1.3 MW. H-mode |
| May 23 2006 02:37:19:843PM | 1060523014 | John Rice | LSN, good plasma, ICRF steady near 2.3 MW. no H-mode |
| Physics Operator Comments | |||
| May 23 2006 08:32:55:720AM | Bill Rowan |
loaded 1060519016 0.8 MA, 5.5 T, nel_04=1e+20 m-2, USN | |
| May 23 2006 08:33:48:407AM | Bill Rowan |
Increase prefill from 16 ms to 18 ms | |
| May 23 2006 08:48:00:563AM | Bill Rowan | DNB GV enabled for the first shot
| |
| May 23 2006 08:52:27:093AM | Bill Rowan |
Delay of approx 1 hour (starting 8:50am). Replace a breaker in TMX cabinet. | |
| May 23 2006 10:07:20:627AM | Bill Rowan |
Delay continues: another hour (from 9:45am). Same problem. | |
| May 23 2006 11:15:42:440AM | 1060523001 | Bill Rowan | 001. Power system test |
| May 23 2006 11:28:16:203AM | 1060523002 | Bill Rowan | 002. nl_04=2e_19 instead of the demand of nl_04=1e+20 |
| May 23 2006 11:59:47:593AM | 1060523004 | Bill Rowan |
004. gas test added a pulse on pg3 of 100 ms at -1s PG3 does not seem to be opening |
| May 23 2006 12:18:02:233PM | 1060523005 | Bill Rowan |
005. gas test. found a loose bnc connector after the previous shot and it was reinstalled no improvement |
| May 23 2006 12:51:28:687PM | 1060523006 | Bill Rowan |
006. gas test prior to this test, the valve was opened using a manually applied ps pulse worked |
| May 23 2006 01:04:16:343PM | 1060523007 | Bill Rowan | 007. plasma attempt
plasma. 1.7 s, disruption during rampdown |
| May 23 2006 01:16:49:500PM | 1060523008 | Bill Rowan | 008. RXU moved out by 1 cm
plasma |
| May 23 2006 01:33:07:297PM | 1060523009 | Bill Rowan |
009. RXU moved out by 1 cm plasma |
| May 23 2006 01:48:22:533PM | 1060523010 | Bill Rowan |
010. increase outer gap to 1.0 cm Rcur reduced by 0.23 cm outer gap is better |
| May 23 2006 02:02:21:780PM | 1060523011 | Bill Rowan |
011. lower ZXL by 1 cm plasma |
| May 23 2006 02:11:54:423PM | 1060523012 | Bill Rowan |
012. lower zxl by 1 cm plasma |
| May 23 2006 02:27:35:673PM | 1060523013 | Bill Rowan |
013. lower zxu by 2 mm |
| May 23 2006 02:37:31:610PM | 1060523014 | Bill Rowan |
014. The request was to load 1060519008. Loaded seg 2 from that shot turned off segment 3 turned on segment 2 LSN, 0.8 MA, 5.5 T, nl_04=1e20 m-2 |
| May 23 2006 02:54:07:220PM | 1060523014 | Bill Rowan |
end of the run. alternator problem that will require more than two hours to diagnose |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 11:04:53:283AM | Plasma | Ok | |
| 2 | 11:20:28:610AM | Plasma | Ok | |
| 3 | 11:42:18:453AM | Plasma | Ok | |
| 4 | 11:54:59:690AM | Test | Ok | Gas Test |
| 5 | 12:11:24:640PM | Test | Ok | gas test |
| 6 | 12:48:34:733PM | Test | Ok | Gas test |
| 7 | 01:01:24:813PM | Plasma | Ok | |
| 8 | 01:13:58:517PM | Plasma | Ok | |
| 9 | 01:27:53:673PM | Plasma | Ok | |
| 10 | 01:42:36:440PM | Plasma | Ok | |
| 11 | 01:55:22:000PM | Plasma | Ok | |
| 12 | 02:08:13:390PM | Plasma | Ok | |
| 13 | 02:20:45:987PM | Plasma | Ok | |
| 14 | 02:33:26:423PM | Plasma | Ok | |