| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Robert Granetz |
| Physics operator(s): | Jim Irby |
| Engineering operator(s): | Andy Pfeiffer,Sam Pierson,Bill Parkin |
| Engineering Operator Run Comment |
| MP #450 -- Disruption mitigation w/mixed gas jet Session leaders: M. Bah |
| Session Leader Plans |
| Entered: Jun 21 2006 04:20:37:400PM |
| Author: Robert Granetz |
MP #450 -- Disruption mitigation w/mixed gas jet
Session leaders: M. Bahktiari, R. Granetz
Physics operator: J. Irby
ECDC overnight and bake at 60 C.
Power systems as on 1060414009 (1.0 MA, 5.4 T, LSN fiducial)
A-coil configuration: normal [+Dtop -Dbot -Jtop +Jbot] and enabled.
Gas Setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar + 2 psi Ne Hybrid DISABLED (PG1)
leave B-side upper with whatever Hybrid disabled
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
No NINJA for this run.
Gas jet plenum has been filled with pure helium at 70 bar. THE SUPPLY
TANK IS A 50/50 MIX OF HELIUM AND ARGON.
Torvac setup: unnecessary diagnostic gate valves (ECE) should be kept
closed on all shots.
Enable the following, assuming no vacuum problems:
Z-bolo shutters, VUV (yes, enable the VUV gate valve)
Necessary diagnostics:
IR divertor camera
Fast PSI camera on B-horizontal, if possible, starting at t=0.800 s, Ar+0
filter
Thomson scattering, with timing set so that one profile is obtained at
t=0.800 s and the other varies shot-to-shot from 0.804 to 0.810 s
(subject to change)
Bolometry
Two pi bolometers
Halo current Rogowskis
SX arrays with fast sampling window (t=0.795 to 0.820 s)
Mirnov Bp fluctuations
-------------------------------------------------------------------------------
ICRF Setup: We'll need 2-3 MW shortly after we begin this MP.
-------------------------------------------------------------------------------
Run plan:
Start with 1060414009, except do not turn off the ZCUR feedback (i.e. P and
D gains should not be zeroed). If this choice is too cumbersome (because
of the F11 updating issue), it is probably okay to use shot 20 from
yesterday (1060621020), except with Btor set to 5.4 T and nl_04 to 1.0e20
m-2. Starting on either shot 1 or 2 we will fire the gas jet at t=0.800 s
with pure helium for two shots. Observe timing of Te and SX decrease, as
well as other typical disruption-relevant signals (halos, Erad/Etot, etc).
Then do an in-situ top-off refill of the plenum using the 50/50 He/Ar mix.
Continue doing two disruption shots with each plenum mix, then a top-off
refill. This will gradually increase the argon fraction of the plenum,
allowing us to do a scan of argon fraction throughout the day, without
needing any cell accesses, in principle. The number of shots will be
greatly reduced compared to most run days because it will take a long time
to pump out the fill lines after each top-off fill.
|
| Physics Operators Plans |
| Entered: Jun 21 2006 04:47:47:437PM |
| Author: Jim Irby |
| MP #450 -- Disruption mitigation w/mixed gas jet
Session leaders: M. Bahktiari, R. Granetz Physics operator: J. Irby ECDC overnight and bake at 60 C. Power systems as on 1060414009 (1.0 MA, 5.4 T, LSN fiducial) but DPCS loaded from 1060621020 A-coil configuration: normal [+Dtop -Dbot -Jtop +Jbot] and enabled. Gas Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar + 2 psi Ne Hybrid DISABLED (PG1) leave B-side upper with whatever Hybrid disabled fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3) No NINJA for this run. Gas jet plenum has been filled with pure helium at 70 bar. THE SUPPLY TANK IS A 50/50 MIX OF HELIUM AND ARGON. Torvac setup: unnecessary diagnostic gate valves (ECE) should be kept closed on all shots. |
| Session Leader Summaries |
| Entered: Jun 22 2006 06:02:01:660PM |
| Author: Mohammad Bakhtiari |
| Disruption mitigation experiments were carried out using pure helium and mixtures of helium (>50%) and argon (<50%). Every thing worked well thanks to Robert Granetz and co-workers in C-Mod. A brief summary of the observations is as follows:
1. For all mixture cases the halo current was less than 120 kA while for those with pure helium injection we got I_halo=138 and 157 kA. 2. The current quench time with mixtures was about 1 ms while it was more than 2.5 ms with pure helium. 3. When the fraction of argon is small the mixture approaches the plasma almost as fast as a pure helium gas, while as we mentioned above the current quench is faster and halo current is lower with mixtures. 4. The density increment with mixtures, when the fraction of argon is small, was comparable with that in pure helium cases. This is one of the advantages of this method to avoid runaway generation. |
| Entered: Jun 22 2006 06:19:30:730PM |
| Author: Robert Granetz |
Run summary for Thursday 22 June 2006: MP#450 Disruption mitigation with mixed gas jet Session leader: M. Bahktiari, R. Granetz Physics operator: J. Irby We got through the run pretty much as planned. We were able to scan the He/Ar ratio successfully, although perhaps we might want smaller increments. At each condition we obtained data on halo currents, radiated energy, Te profiles, soft x-rays, density, etc. There were clear differences as we varied the mixture ratio. I haven't had a chance to assemble all the information and get a clear picture yet, but Val Izzo, Mohammed Bahktiari, and Matt Reinke are also looking at the data. After the first few shots we got the RGA to give us post-shot information on the He/Ar ratio, which seems to correlate fairly well with the volume/pressure estimates I was making. The gas jet hardware worked well, particularly considering that it was not designed to do gas mixture studies. Because of all the required pumpouts of the machine and the gas jet system, we only got 13 shots (which is one more than I was hoping for). Plasma operation went well, and again there were no fizzles or duds all day. |
| Physics Operator Summaries |
| Entered: Jun 22 2006 05:11:29:327PM |
| Author: Jim Irby |
| The machine ran extremely well today (twelve plasmas/twelve attempts).
Th only adjustments made were small, probably unnecessary, adjustments to the prepuff gas. Time between shots was very long since the machine was going up to at least 300 mTorr from the massive gas puffs (we need to write down the recovery procedure). We had trouble adjusting SV4 properly to produce a good range in pressure for the RGA. In addition, its position was not reproducible. The same setting of 140 clicks could result a factor of 100 variation in the pumpstack pressure. |
| Session Leader Comments | |||
| Jun 21 2006 05:58:24:243PM | Robert Granetz | The night before the run, the plenum contains 70+ bar of pure helium. I evacuated the fill lines, hooked up the bottle of 50/50 He/Ar mix (2400 psi), and set the regulator at 1000+ psi (70+ bar). But I've left the fill lines evacuated. The gas jet system is ready to go. The firing signal currently goes through the interface box, so in principle it may not fire during a fizzle, although I'm not sure. | |
| Jun 22 2006 08:53:52:360AM | Robert Granetz | Fast gas trigger is enabled in camac. 50 kHz sampling window is enabled for the SX arrays from t=0.795 to 0.820 s. | |
| Jun 22 2006 08:57:53:800AM | Robert Granetz | We will have to supply the mixed gas directly from its bottle, rather than from just the intrinsic volume of the gas fill lines, because this intrinsic volume is way too small. This will reduce the accuracy with which we know the plenum mixture, but we will have the RGA sampling the torus gas after each shot, so that should help. | |
| Jun 22 2006 09:22:50:693AM | 1060622001 | Robert Granetz | This was too much gas. I had the fast valve set for 2.0 ms, which is the setting for argon. I will reduce this to 1.3 ms for the next shot (still pure helium). |
| Jun 22 2006 09:36:59:517AM | 1060622001 | Robert Granetz | I was going to do a repeat shot with pure helium, but I calculate that if I do a top-off fill with the 50/50 mix now, I will end up with 90% He/ 10% Ar. If I did a repeat shot, I will have even more of a changeover, which is more than I want. So I will not do a repeat shot with pure helium, but rather do the top-off fill now. |
| Jun 22 2006 11:20:42:133AM | 1060622001 | Robert Granetz | Shot 01 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.805 s. Current quench duration is about 3 ms. I_halo=138 kA Prf=2.0 MW Wth=125 kJ. Plenum gas: pure helium Pulse length (ms): 2.0 Plenum pre -pulse pressure (bar): 72 Plenum post-pulse pressure (bar): 56 Plenum change in pressure (bar): 16 |
| Jun 22 2006 10:04:01:953AM | 1060622002 | Robert Granetz | Pulse length was still 2.0 ms. My mistake, I guess I didn't "OK" the change. But I definitely have loaded it now...it will be 1.3 ms on the next shot. This should have been a 90/10 He/Ar mix. The current quench is much faster than with pure helium (1 ms compared to 3 ms), and the halo current is 77 kA, compared to 138 kA. I wish we could do smaller mixture increments. If I had used a shorter pulse, we could have had an intermediate point. I'm planning now on doing one shot at each mixture, then around mid-day I will go into the cell and reinstall the pure helium bottle and start another series of shots. Hopefully we will also get the RGA to work then too. |
| Jun 22 2006 10:05:47:203AM | 1060622002 | Robert Granetz | For the next shot I will do another top-off fill, which should bring the mixture to about 83/17 He/Ar. |
| Jun 22 2006 11:20:25:697AM | 1060622002 | Robert Granetz | Shot 02 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.805 s. Current quench duration is about 1 ms. I_halo=77 kA Prf=2.0 MW Wth=113 kJ. Plenum gas: 90% He / 10% Ar (calculated) Pulse length (ms): 2.0 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 57 Plenum change in pressure (bar): 13-14 |
| Jun 22 2006 10:28:14:397AM | 1060622003 | Robert Granetz | Got the desired valve pulse length this time, and correspondingly less gas injected. Next shot, repeat with this 83/17 mixture. Plenum is at 63 bar. |
| Jun 22 2006 11:20:04:930AM | 1060622003 | Robert Granetz | Shot 03 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.8047 s. Current quench duration is about 1 ms. I_halo=100 kA Prf=2.0 MW Wth=125 kJ. Plenum gas: 83% He/ 17% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 63 Plenum change in pressure (bar): 7-8 |
| Jun 22 2006 11:19:46:320AM | 1060622004 | Robert Granetz | Shot 04 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.805 s. Current quench duration is about 1 ms. I_halo=78 kA Prf=2.0 MW Wth=122 kJ. Plenum gas: 83% He/ 17% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 63 Plenum post-pulse pressure (bar): 56.5 Plenum change in pressure (bar): 6-7 |
| Jun 22 2006 11:21:30:367AM | 1060622004 | Robert Granetz | I will do another top-off fill for the next shot. This will bring the fractions to 77% He / 23% Ar (calculated). Also, the butterfly/bypass valve on the RGA system is now fixed. Starting with the next shot we should get argon measurements. When we reset to helium at mid-day and do another scan, we should have the RGA for all those shots. |
| Jun 22 2006 02:26:05:600PM | 1060622004 | Mohammad Bakhtiari | Sx-ray signals at edge start to drop at ~0.8033 s
Maximum electron density before current quench nl04~4e20 m-2. Maximum Halo current during current quench is ~80 kA. |
| Jun 22 2006 11:48:17:143AM | 1060622005 | Robert Granetz | Shot 05 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.805 s. Current quench duration is about 1 ms. I_halo=90 kA Prf=2.0 MW Wth=121 kJ. Plenum gas: 77% He/ 23% Ar (calculated) Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 64.5 Plenum change in pressure (bar): 6 |
| Jun 22 2006 12:03:04:550PM | 1060622005 | Robert Granetz | The RGA is dominated by the He and Ar peaks. The raw RGA amplitudes are 1.6e-6 and 1.5e-6. The RGA sensitivity of Ar wrt N2 is 1.29, and for He wrt N2 is 0.18. The the relative sensitivity of Ar to He is 7.17. Therefore the raw amplitude ratio of He/Ar needs to be multiplied by 7.17. So I think the RGA is telling us the ratio is 88% He / 12% Ar. My plenum mixing calculations give 77% He/ 23% Ar. We can sort of do an in-vessel calibration of the RGA using the 50/50 mix. We'll do this on shot 7. The next shot (06) will be a repeat (77/23 He/Ar) |
| Jun 22 2006 02:05:03:200PM | 1060622005 | Robert Granetz | In order to make the RGA-measured ratio on shot 08 come out to 50% He/ 50% Ar, I have to assume a relative correction factor of 2.766 (i.e. the helium peak has to be multiplied by 2.766 relative to the argon peak). Applying this relative correction factor to the RGA data on shot 05 gives 75% He/ 25% Ar, which compares very well to my mixing calculations of 77% He/ 23% Ar. |
| Jun 22 2006 02:25:30:850PM | 1060622005 | Mohammad Bakhtiari | Sx-ray signals at edge start to drop at ~0.8034 s
Maximum electron density before current quench nel4~4e20 m-2. Maximum Halo current during current quench is ~90 kA. |
| Jun 22 2006 12:23:22:587PM | 1060622006 | Robert Granetz | After this shot I pumped out the plenum and supply lines and filled the plenum with the 50/50 He/Ar mix. We will use this on the next shot, both to get a 50/50 data point, and also to calibrate the RGA. |
| Jun 22 2006 12:26:13:353PM | 1060622006 | Robert Granetz | The raw data from the RGA on this shot is 2.1e-6 He and 2.0e-6 Ar. Using the correction factor of 7.17 (see previous entry), this gives 88% He/ 12% Ar again (not yet calibrated with the 50/50 mix). |
| Jun 22 2006 02:26:52:303PM | 1060622006 | Mohammad Bakhtiari | Sx-ray signals at edge start to drop at ~0.8035 s
Maximum electron density before current quench nl04~4e20 m-2. Maximum Halo current during current quench is ~105 kA. |
| Jun 22 2006 02:56:19:410PM | 1060622006 | Robert Granetz | Shot 06 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.805 s. Current quench duration is about 1.5 ms. I_halo=105 kA Prf=2.0 MW Wth=116 kJ. Plenum gas: 77% He/ 23% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 64.5 Plenum post-pulse pressure (bar): 58.5 Plenum change in pressure (bar): 6 |
| Jun 22 2006 12:51:35:020PM | 1060622007 | Robert Granetz | Strange result. Much less gas went into the machine, but we still got a gas jet disruption. The valve worked properly. It seems that this is a result of increasing the argon fraction to 50%. We'll have to study this a bit. For the next shot, increase the valve pulse length to 2.0 ms. |
| Jun 22 2006 12:57:24:753PM | 1060622007 | Robert Granetz | Shot 07 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.806 s. Current quench duration is about 1.5 ms. I_halo=94 kA Prf=2.0 MW Wth=123 kJ. Plenum gas: 50% He/ 50% Ar (straight from the bottle) Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 70 Plenum change in pressure (bar): 0.5 |
| Jun 22 2006 01:03:25:560PM | 1060622007 | Robert Granetz | RGA readings were 2.25e-7 for He and 5.0e-7 for Ar. Using a correction factor of 7.17 gives a mix ratio of 76% He / 24% Ar. So either the RGA correction factor needs to be changed (which is why we did this calibration shot), or the delivery of argon was reduced because of the 1.3 ms pulse length. We'll find out on the next shot when we use a 2.0 ms pulse length for the fast valve. |
| Jun 22 2006 02:27:46:600PM | 1060622007 | Mohammad Bakhtiari | Sx-ray signals at edge start to drop at ~0.8043 s
Maximum electron density before current quench nl04~4e20 m-2. Maximum Halo current during current quench is ~95 kA. |
| Jun 22 2006 01:12:27:043PM | 1060622008 | Robert Granetz | Shot 08 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.8057 s. Current quench duration is about 1 ms. I_halo= kA Prf=2.0 MW Wth=123 kJ. Plenum gas: 50% He / 50% Ar (straight from the mix bottle) Pulse length (ms): 2.0 Plenum pre -pulse pressure (bar): 70 Plenum post-pulse pressure (bar): 62 Plenum change in pressure (bar): 8 |
| Jun 22 2006 01:13:28:873PM | 1060622008 | Robert Granetz | The RGA raw data is 1.11e-6 for He, 3.07e-6 for Ar. Using a correction factor of 7.17 gives a mixture of 72% He/ 28% Ar. So it's clear that the factor of 7.17 needs to be changed. |
| Jun 22 2006 01:14:26:780PM | 1060622008 | Robert Granetz | For the next shot, I will purge the plenum and gas lines and refill with pure helium. I will need a cell access to switch the gas bottles. Also, the fast valve pulse width will be reduced back to 1.3 ms. |
| Jun 22 2006 01:53:40:250PM | 1060622008 | Mohammad Bakhtiari | Sx-ray signals at edge start to drop at ~0.8033 s and current quench starts at 0.8057. It seems it has taken a longer time, compare to other cases, to start current quench.
|
| Jun 22 2006 02:04:49:560PM | 1060622008 | Robert Granetz | In order to make the RGA-measured ratio on shot 08 come out to 50% He/ 50% Ar, I have to assume a relative correction factor of 2.766 (i.e. the helium peak has to be multiplied by 2.766 relative to the argon peak). Applying this relative correction factor to the RGA data on shot 05 gives 75% He/ 25% Ar, which compares very well to my mixing calculations of 77% He/ 23% Ar. |
| Jun 22 2006 02:58:42:110PM | 1060622009 | Robert Granetz | Shot 09 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.8054 s. Current quench duration is about 2.5 ms. I_halo=157 kA Prf=2.0 MW Wth=123 kJ. Plenum gas: pure helium Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 60 Plenum change in pressure (bar): 10.5 |
| Jun 22 2006 03:09:12:470PM | 1060622009 | Robert Granetz | RGA shows pure helium, as expected. For the next shot I've topped off the plenum with the 50/50 mix. This should result in a mixture ratio of 92% He/ 8% Ar. Can't really do much smaller increments with the bottle we have. |
| Jun 22 2006 03:11:04:750PM | 1060622009 | Mohammad Bakhtiari | Sx-ray at edge start to decrease at ~0.8028 s.
Halo current ~155 kA. Maximum nl04~6e20 m-2 before current quench. Current quench at ~0.8055 ms. Comparing to the first shot with 2 ms gas injection, it seems the gas pulse length is important in disruption mitigation. |
| Jun 22 2006 03:27:15:197PM | 1060622010 | Robert Granetz | Shot 10 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.8047 s. Current quench duration is about 1 ms. I_halo=107 kA Prf=2.0 MW Wth=118 kJ. Plenum gas: 92% He/ 8% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 62.5 Plenum change in pressure (bar): 8 |
| Jun 22 2006 03:31:31:040PM | 1060622010 | Robert Granetz | For the next shot, do another top-off fill at Mohammed's request. This should bring the mix ratio to 86% He / 14% Ar. |
| Jun 22 2006 03:32:53:353PM | 1060622010 | Mohammad Bakhtiari | Sx-ray at edge start to decrease at ~0.8028 s (almost same time
as a pure helium in previous shot) With less Halo current ~105 kA (compare to pure helium). Maximum nl04~7e20 before current quench. Current quench at ~0.805 ms (faster than that in pure helium). |
| Jun 22 2006 03:35:32:210PM | 1060622010 | Robert Granetz | The RGA measurements for this shot, using the new calibration number of 2.766, gives a mixture ratio of 87% He / 13% Ar. My mixing calculation gives 92% He / 8% Ar. |
| Jun 22 2006 04:04:17:453PM | 1060622011 | Robert Granetz | Shot 11 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.8047 s. Current quench duration is about 1 ms. I_halo=120 kA Prf=2.0 MW Wth=118 kJ. Plenum gas: 87% He / 13% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 63.5 Plenum change in pressure (bar): 7 |
| Jun 22 2006 04:08:43:843PM | 1060622011 | Robert Granetz | The RGA looks like it screwed up on this shot. It might not have recorded a post-shot mass spectrum. |
| Jun 22 2006 04:16:32:530PM | 1060622011 | Robert Granetz | For the next (and probably final) shot, we want to do a repeat at this mixture in order to get the RGA data. |
| Jun 22 2006 04:35:46:060PM | 1060622012 | Robert Granetz | Shot 12 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.8048 s. Current quench duration is about 1 ms. I_halo=114 kA Prf=2.0 MW Wth=121 kJ. Plenum gas: 87% He / 13% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 63.5 Plenum post-pulse pressure (bar): 56 Plenum change in pressure (bar): 7.5 |
| Jun 22 2006 04:38:13:653PM | 1060622012 | Robert Granetz | We'll have one more shot. I've done a final top-off, which should bring the mixture to 79% He / 21% Ar. |
| Jun 22 2006 04:47:01:940PM | 1060622012 | Mohammad Bakhtiari | Sx-ray at edge start to decrease at ~0.8032 s.
Halo current ~114 kA. Maximum nl04~3e20 cm-2 before current quench. Current quench at ~0.805 ms. |
| Jun 22 2006 04:50:33:910PM | 1060622012 | Robert Granetz | The bypass valve on the RGA didn't work properly on this shot, so the post-shot spectrum is very low amplitude (10^-8 scale). But by playing around manually with the valve, Jim was able to get a later spectrum in the 10^-6 range, which I read off the screen with the cursor: He 5.3e-6 Ar 2.8e-6 With the calibration number of 2.766, this gives a ratio of 84% He / 16% Ar. |
| Jun 22 2006 05:07:20:453PM | 1060622013 | Robert Granetz | Shot 13 -- Good shot. Gas jet fired at t=0.800 s. Current quench spike is at t=0.805 s. Current quench duration is about 1 ms. I_halo=107 kA Prf=2.0 MW Wth=119 kJ. Plenum gas: 79% He / 21% Ar Pulse length (ms): 1.3 Plenum pre -pulse pressure (bar): 70.5 Plenum post-pulse pressure (bar): 64.5 Plenum change in pressure (bar): 6 |
| Jun 22 2006 05:07:48:577PM | 1060622013 | Robert Granetz | End of run. I will close the bottle and pump everything out. |
| Jun 22 2006 05:11:01:343PM | 1060622013 | Robert Granetz | RGA gives 80% He / 20% Ar |
| Jun 22 2006 05:18:36:273PM | 1060622013 | Mohammad Bakhtiari | Sx-ray at edge start to decrease at ~0.8032 s.
Halo current ~110 kA. Maximum nl04~5e20 m-2 before current quench. Current quench at ~0.8047 ms. |
| Physics Operator Comments | |||
| Jun 22 2006 09:40:51:237AM | 1060622001 | Jim Irby | loaded from 1060621020
bt to 5.4 T (150kA) nl04 request at 1.0e29/m^2 at 0.6 s --- increased density rate of rise before 0.6 to get to the target. loaded/clean plasma --- got rf too gatevalves toggled closed before the shot for 5 minutes with bypass at 270 clicks. But 270 was too large --- RGA tripped TMP2 shutdown --- water flow? target density reached by h-mode time --- rf raises density a little |
| Jun 22 2006 10:17:57:510AM | 1060622002 | Jim Irby | 30 minute delay before shot to get pumping system going again and for Bob to make changes to the big puff.
bypass to 180 clicks --- still too large plasma |
| Jun 22 2006 10:55:22:767AM | 1060622003 | Jim Irby | no DPCS changes
plasma bypass at 150 clicks still too much -- now bypass appears to be broken. Bob Childs goes into cell to check bypass |
| Jun 22 2006 11:17:28:773AM | 1060622004 | Jim Irby | bypass fixed --- set at 130 clicks
ready for shot after about 41 minutes prepuff from 20 to 21 ms. plasma |
| Jun 22 2006 12:05:15:440PM | 1060622005 | Jim Irby | bypass 140
raised early pg3 gas puff to help with neuts/hards from 60 to about 80V gatevalves toggled closed for 10 minutes as of last shot plasma RGA provides good data at last |
| Jun 22 2006 12:17:33:760PM | 1060622006 | Jim Irby | no DPCS changes
plasma rga data looks good and making into MDS |
| Jun 22 2006 12:51:08:357PM | 1060622007 | Jim Irby | No control system changes
cell entry before this shot as Bob makes changes to the gas mix. ready for shot at 26 minutes plasma --- pressure in machine only 30 mTorr with current He/Ar 50/50 mix |
| Jun 22 2006 02:14:35:853PM | 1060622008 | Jim Irby | repeat DPCS
plasma |
| Jun 22 2006 02:59:15:190PM | 1060622009 | Jim Irby | long break to enter cell and make changes to gas puff system --- 1:48
plasma |
| Jun 22 2006 03:36:21:413PM | 1060622010 | Jim Irby | prepuff to 21 ms from 20 ms
plasma ratiomatic turned on for this shot 8.1e-5 Torr at t=0 --- will drop prepuff or next shot |
| Jun 22 2006 04:20:39:440PM | 1060622011 | Jim Irby | prepuff from 21 to 18 ms
start cycle at 35 minutes plasma no RGA data... |
| Jun 22 2006 04:45:14:190PM | 1060622012 | Jim Irby | no DPCS changes
RGA is working cycle start time: 31 minutes plasma RGA produced data, but the bypass valve at 140 clicks is not the same as it was. Basepressure in pumpstack 1 is on the 1e-8 Torr range vs 1e-6 range earlier today. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:07:56:263AM | Plasma | Ok | |
| 2 | 09:45:33:940AM | Plasma | Ok | |
| 3 | 10:18:28:700AM | Plasma | Ok | |
| 4 | 11:02:31:373AM | Plasma | Ok | |
| 5 | 11:34:52:787AM | Plasma | Ok | |
| 6 | 12:04:02:283PM | Plasma | Ok | |
| 7 | 12:33:32:183PM | Plasma | Ok | |
| 8 | 01:01:12:950PM | Plasma | Ok | |
| 9 | 02:53:33:423PM | Plasma | Ok | |
| 10 | 03:22:31:633PM | Plasma | Ok | |
| 11 | 03:58:44:220PM | Plasma | Ok | |
| 12 | 04:28:51:950PM | Plasma | Ok | |
| 13 | 05:01:48:467PM | Plasma | Ok | |