Alcator C-Mod Run 1070403 Information

Back to runs

Miniproposals
Miniproposal:470
Date Filed: 3/8/2007
Title:Localization of ECDC flux profiles and boron film growth using vertical fields
First Author:Dennis Whyte
Session Leader:Dennis Whyte (shots 601-629)

Operators
Session leader(s):Dennis Whyte
Physics operator(s):
Engineering operator(s):

Engineering Operator Run Comment

Session Leader Plans
Entered: Apr 3 2007 01:38:56:540PM
Author: Dennis Whyte
ECDC with vertical field

This will continue our first attempts (1070319XXX) at localizing plasma flux to surfaces
during ECDC by applying a finite vertical field to the toroidal field. The main focus
of today's experiment will be using the large area Langmuir probe on the S3 (Surface
Science Station) to obtain radial profiles of the plasma properties by scanning the
S3 radially through the chamber with the ECDC power, resonance loacation and Bv fixed.
In addition we will use the Wide camera view and fixed probes with high
gain to diagnose the plasma losses to surfaces. With fixed probes on 1070319 we
found the radial width to be ~5-10 cm, However there were some hints that the
plasma width changes with scanning the resonanc location, particularly to R > 62 cm
which is when the resonance is located on the horizontal portion of the lower outer divertor
target.


The end goal is to obtain better
localization for plasma cleaning and boronization film deposition.

We will attempt to diagnose the following conditions

B_v = 0 (reference)

B_v / B_t ~ 10%, R_res = 60 cm (just inside the vertical target)

B_v / B_t ~ 5% , R_Res = 60 cm (to see effect of Bv/Bt on SOL width)

B_v/B_t ~10%, R_res = 70 cm (effect of placing resonance on horizontal target)


The vertical field is being obtained by a manually connected current supply to the EF4
coils. 130 Amp in each EF4 coils = = 260 A PS current --> 9 mT vertical field.

B_V/B_res (%) ~ 0.04 * I_coil_PS (A)

Since this occurs outside of the usual C-Mod shots cycle we will use
our own convention for shot numbers and will keep track of them self-consistently

We will "slave" the shot number to the S3 shot convention which
will begin at 601. The edge tree shots which will include the
fixed probe data will have a shot convention starting at 901.
The image file names will be correlated to the edge tree number.





Physics Operators Plans

Session Leader Summaries
Entered: Apr 3 2007 07:08:12:090PM
Author: Dennis Whyte
The first successful physics experiment with S3!

We obtained many, many profiles of plasma Isat, density, etc. with the
Langmuir probe on S3 in an attempt to understand and quantify the
radial profiles during ECDC. To first order we recreated the results of two
weeks ago in that the local plasma flux at the LH grill more or less disappears
with the application of vertical field, although we have a better measure of
this today with higher gain channels on the LH probe.

We did two basic scans:

1) Fixing the location of the S3 probe at R ~ 168 cm and scanning the
resonance location past it in 5 cm steps.
2) Fixing the resonance lcoation and scanning the probe /w changing Bv/Bt

The radial profile is complicated. It appears that the peak Isat is broad
and about 10 cm outboard of the resonance location. We don't know
the cause of this (upper hybrid resonance?). The applicaiton of the vertical
field made the radial profile considerably narrower in major radius, qualitatively
consistent with images and fixed probes.

This will require more analysis for firm conclusion about the
optimal B-vertical, etc.







Physics Operator Summaries

Session Leader Comments
Apr 3 2007 02:29:21:510PM1070403601Dennis WhyteNo vertical field fiducial.

R_res = 60 cm
B_v / Bt = 0
Power_RF= 2.5 kW

S3 radial scan: 58 - 126 cm

QMB frequency, radial position, and QMB temperatures
appear reasonable for the scan.
There appears to be a problem with the voltage sweep on
the S3 langmuir probe, which should have a constant
sweep on it, but doesn't.

The 9xx shots will record the fixed probe data.
We have the upper divertor fixed probes 12 and 14 on 50x gain
and the LH grill probe on 50x gain.

The FIXED PROBE DATA IS INVALID ON THIS SHOT DUE TO OVERCURRENTING






Apr 3 2007 05:38:57:840PM1070403602Dennis WhyteNo vertical field fiducial.

R_res = 60 cm
B_v / Bt = 0
Power_RF= 2.5 kW
Pressure = 2e-4 Torr

S3 radial scan: 105 - 58 cm

Will watch oscilloscope trace of S3 probe voltage to see
what the problem is

THIS SHOT DATA IS NULL. The I-V boards
over currented due to increased gain.







Apr 3 2007 02:47:37:147PM1070403603Dennis WhyteNo vertical field fiducial.

R_res = 60 cm
B_v / Bt = 0
Power_RF= 2.5 kW

S3 radial scan: cm

Gains have been reduced on the I-V boards to avoid
over-currenting.

Clear signal of plasma flux on LH probe.
Fixed probes need capacitance tuning but show low
signal as usual without vertical field.

Good profile data from the S3 langmuir probe vs. R.






Apr 3 2007 02:59:34:650PM1070403604Dennis WhyteNo ECDC fiducial for zeroing probes

S3 radial scan: cm

Brian Labombard has tuned the capicatances of the probes
on S3 and LH launcher.

Shot 904 on edge tree.

Result:

S3 Langmuir probe current is in the bit noise.
QMB freq., sensor temperature etc., are very constant
versus R. excellent test of stability of the the diagnostic
signals versus probe position.






Apr 3 2007 03:00:28:493PM1070403604Dennis WhyteNo ECDC fiducial for zeroing probes

S3 radial scan: 105- 55 cm

Brian Labombard has tuned the capicatances of the probes
on S3 and LH launcher.

Shot 904 on edge tree.

Result:

S3 Langmuir probe current is in the bit noise.
QMB freq., sensor temperature etc., are very constant
versus R. excellent test of stability of the the diagnostic
signals versus probe position.






Apr 8 2007 09:36:19:430PM1070403605Dennis WhyteB_v/Bt = 8 %
I_EF4_PS = 200 A

R_res = 70 cm
Power_RF= 2.5 kW

S3 radial scan: 57 - 105 cm

The speed of the scan will be doubled to halve the
acquisition time.

LH probe flux goes to ~ zero while the flux to the
upper fixed probes becomes measurable (as with previous day)

More localization of the plasma profile, but strangely broad
INSIDe the resonance?

I THINK I MESSED UP THIS SHOT DESIGNATION SINCE
AN EXACT COPY OF 06?


Apr 3 2007 03:31:02:463PM1070403606Dennis WhyteB_v/Bt = 8 %
I_EF4_PS = 200 A

R_res = 70 cm
Power_RF= 2.5 kW

S3 radial scan: 57 - 105 cm

The speed of the scan will be doubled to halve the
acquisition time.

LH probe flux goes to ~ zero while the flux to the
upper fixed probes becomes measurable (as with previous day)

More localization of the plasma profile, but strangely broad
INSIDe the resonance?



Apr 3 2007 03:38:31:230PM1070403607Dennis WhyteB_v/Bt = 8 %
I_EF4_PS = 200 A

R_res = 70 cm
Power_RF= 2.5 kW

S3 radial scan: 57 - 105 cm

The Langmuir probes are in Isat collection mode for this shot.

No images for this shot.





Apr 3 2007 03:39:01:933PM1070403608Dennis WhyteNo ECDC fiducial for Isat colleciotn on probes




Apr 3 2007 07:13:11:073PM1070403609Dennis WhyteR_res = 60 cm
B_v/Bt = 8%

Probes are in Isat collection mode.

Images are 909 a and 909 b to signify the
probe outside and inside thr esonance respectively.
Control room speculation is that the S3 probe
itself may be perturbing.

Shadow of s3 probe and its helicity is clear in images.
It appears we have the same helicity as regular shots.

POSSIBLE THAT THIS RESONANCE VALUE IS INCORRECT!
MUST BE CHECKED VERSUS TREND DATA.





Apr 3 2007 04:17:22:137PM1070403611Dennis WhyteR_res = 60 cm
B_v/Bt = 0 %

Probes are in Isat collection mode.

S3 swept from 57 cm to 105 cm.







Apr 3 2007 04:34:01:683PM1070403612Dennis WhyteR_res = 50 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:37:23:540PM1070403613Dennis WhyteR_res = 55 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:38:33:213PM1070403614Dennis WhyteR_res = 60 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:40:58:887PM1070403615Dennis WhyteR_res = 65 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:42:53:637PM1070403616Dennis WhyteR_res = 70 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:46:03:713PM1070403617Dennis WhyteR_res = 75 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:48:16:463PM1070403618Dennis WhyteR_res = 80 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:49:58:200PM1070403619Dennis WhyteR_res = 85 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:51:29:887PM1070403619Dennis WhyteR_res = 85 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:53:10:730PM1070403620Dennis WhyteR_res = 45 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.







Apr 3 2007 04:54:53:433PM1070403620Dennis WhyteR_res = 45 cm
B_v/Bt = 8 %

Probes are in Isat collection mode.

Probe position: 68 cm

Apr 3 2007 05:36:52:667PM1070403621Dennis WhyteR_res = 60 cm
B_v/Bt = 8 %

D2 pressure = 5e-5 torr, lower than previous value of 2e-4 Torr

Probes are in Isat collection mode.

Probe position scanned.

Apr 3 2007 05:39:29:840PM1070403622Dennis WhyteB_res = 50 cm
B_v/Bt = 8%
Pressure = 5e-5 Torr

Probes in Isat mode


Apr 3 2007 05:49:27:433PM1070403623Dennis WhyteB_res = 50 cm
B_v/Bt = 8%
Pressure = 5e-5 Torr

Probes in Isat mode

Repeat of the last shot, but pulling the S3 probe
out rather than going in.



Apr 3 2007 06:07:26:340PM1070403624Dennis WhyteB_res = 50 cm
B_v/Bt = 0 %
Pressure = 5e-5 Torr

Probes in Isat mode

The visible camera shows that the probe is perturbing the
emissions as it moves radially inward

This shows a clear difference, i.e. much broader in outboard radial profile
than with Bv/Bt = 8%, although it's clear that the nearby limiter structures
still effect the local plasma density

Apr 3 2007 06:06:06:247PM1070403625Dennis WhyteB_res = 50 cm
B_v/Bt = 2 %
Pressure = 5e-5 Torr

Probes in Isat mode
Speeding up the probe scan rate (i.e. radial speed)
so that we can get home tonight.




Apr 3 2007 06:14:47:760PM1070403626Dennis WhyteB_res = 50 cm
B_v/Bt = 4 %
Pressure = 5e-5 Torr

RF power = 2.45 kW

Probes in Isat mode



Apr 3 2007 06:23:42:527PM1070403627Dennis WhyteB_res = 50 cm
B_v/Bt = 6 %
Pressure = 5e-5 Torr

Probes in Isat mode

Missed Fixed Langmuir probe data shot.


Apr 3 2007 06:23:05:103PM1070403628Dennis WhyteB_res = 50 cm
B_v/Bt = 8 %
Pressure = 5e-5 Torr

Probes in Isat mode
Slowed down the S3 probe movement since it was causing
the slide mechanism to shake.

Apr 3 2007 06:27:39:230PM1070403629Dennis WhyteB_res = 50 cm
B_v/Bt = 9.5 % (I_EF4 = 230 A)
Pressure = 5e-5 Torr

Probes in Isat mode

Physics Operator Comments

Engineering Operator Comments
ShotTimeTypeStatusComment