| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change |
| Active MHD | yes | Fully operational | Mar 28 2007 09:19PM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes |
| BES | yes | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Feb 06 2007 10:00AM (bravenec) | Ron Bravenec | Beam Emission Spectroscopy | bravenec |
| Bolometers | yes | 2Pi diode operational, 2Pi foil being upgrade for noise resistance. Midplane foils calibrated and operational, data in the tree. Outboard midplane AXUV calibrated and operational, data in the tree. Full midplane and divertor views being digitized. ***NO SAFETY HAZARD FOR IN-VESSEL*** | Sep 14 2007 11:59AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke |
| Boronization | no | First Boronization 5/9/07 Bottle has been removed from the cell | Sep 14 2007 12:42PM (dekow) | Jim Irby | Boronization | dekow,irby |
| CNPA | no | | Jan 14 2007 02:06PM | Ron Parker | Compact Neutral Analyzer | parker |
| Cryopump - Upper Divertor | no | LN2 manual valve is closed. LHe valve is closed and disconnected from PLC. | Sep 14 2007 01:26PM (labombard) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard |
| CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[75,4:87.4]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Sep 19 2007 06:14PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,rachmcd,rowan |
| D Alpha | yes | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Mar 11 2007 10:28PM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe |
| Dalsa | yes | camera is re-installed, and view has been calibrated | Feb 26 2007 03:28PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar |
| Disruption Mitigation | no | safe for vessel entry | Sep 14 2007 01:25PM (granetz) | Bob Granetz | Gas Jet | granetz,whyte |
| Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry |
| Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,ldorf,terry |
| DNB | no | safe for vessel entry (gate valve "open" hose is unplugged) | Sep 14 2007 01:26PM (granetz) | Bob Granetz | Diagnostic Beam | beals,granetz |
| FRC-ECE | yes | Chs 17-32 working | Aug 27 2007 01:11PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips |
| G-Side Ratiomatic | no | Power is off. Gauge is removed from vessel. | Sep 14 2007 01:38PM (labombard) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland |
| GPC | no | Detector warm. | Sep 14 2007 01:47PM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt |
| GPC2 | no | Detectors warm. Most channels (except 1,5,8,10,17) operational. | Sep 14 2007 01:48PM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt |
| GPI | yes | New view just outside of the lower X-point is operational, but data is being archived locally , not to the tree. Midplane GPI is not operational. | Mar 27 2007 01:59PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben |
| H/D | yes | spectral calibration needs to be checked, but system should be ready for the run | Feb 26 2007 03:28PM (marmar) | Earl Marmar | H/D Ratio | marmar |
| Hirex Jr | yes | | Mar 06 2007 08:59AM (rice) | John Rice | High Resolution X-Ray | ince,rice |
| Hirex Sr | yes | Storing Data, but profiles not yet available | Apr 27 2007 01:20PM (ince) | John Rice | High Resolution X-Ray | ince,rice |
| HXR | yes | Something might be wrong with channel 26; all others working fine. | Mar 23 2007 10:43AM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt |
| ICRF D-Antenna | no | Coaxial line disconnected from the antenna | Sep 14 2007 11:24AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin |
| ICRF E-Antenna | no | coaxial line disconnected from the antenna | Sep 14 2007 11:24AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin |
| ICRF J-Antenna | no | Antenna is still connected. We will only do transmitter work after the lines are disconnected and capped. | Sep 14 2007 11:26AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin |
| Lower Hybrid | yes | LH is available with transmitters 2-11 working. | Aug 24 2007 11:36AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker |
| LPI | no | | Oct 12 2007 12:41PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar |
| Ly-alpha | yes | Midplane calibrated and operational, data being stored in tree. Divertor views showing significant noise, and not available. Upper view being digitized and analyzed. ***NO SAFETY HAZARD FOR IN-VESSEL*** | Sep 14 2007 11:57AM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke |
| McPherson | yes | System under vacuum but not safed to machine. Gate valve air lines need to be removed. | Sep 14 2007 11:57AM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry |
| Michelson | no | Detector Warm. Gate valve disabled. | Sep 14 2007 01:47PM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt |
| MKS | yes | E-Top, E-Bottom, F-top (cryo), G-side, and B-bottom are operational. F-top gauge has a 'sniffer tube' to measure pressures in cryopump gas box. | Mar 20 2007 06:42PM (g) | Brian LaBombard | Baratron pressure gauges | labombard |
| MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard |
| MSE | no | System is SAFE as of 9/14/2007 11:30 AM. We will be performing a variety of calibrations and inspections over the next several weeks. | Sep 14 2007 11:32AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott |
| Neutrons | no | Voltages are off on all detectors. Supplies are turned off. Key removed from supply to all global detectos, high voltage lead disconnected from He3 bank | Sep 14 2007 11:24AM (fiore) | Catherine Fiore | Neutron Detectors | fiore |
| Neuts and Hards | yes | operational | Mar 21 2007 04:29PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby |
| NINJA | yes | All capillaries displayed by the NINJA_CONTROL GUI have been tested. NINJA puffed on 1070329009 (A-B limiter). | Mar 29 2007 11:47AM (terry) | Brian LaBombard | NINJA gas puff | labombard,terry |
| PCI | no | Both CO2 and HeNe Lasers are disabled----- safe for machine entry. | Sep 14 2007 03:21PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab |
| Penning Gauges | no | All high voltage power supplies have been turned off and unplugged | Sep 14 2007 12:59PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard |
| Plasma TV | yes | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV (without an ND filter) are operational. | Mar 27 2007 01:53PM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe |
| Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby |
| Probe Array - ISD | no | Probe voltage power supplies have been turned off. | Sep 14 2007 01:01PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard |
| Probe Array - LH | no | Probe voltage power supplies have been turned off. | Sep 14 2007 01:01PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard |
| Probe Array - OSD | no | Probe voltage power supplies have been turned off. | Sep 14 2007 01:01PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard |
| Probe Array - UDIV | no | Probe voltage power supplies have been turned off. | Sep 14 2007 01:02PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard |
| Reflectometer | no | System off | Sep 14 2007 02:46PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar |
| Scanning Probe - ASP | no | Probe voltage power supplies have been turned off. Pneumatic air supply has been disconnected. Vacuum system is up to air. | Sep 14 2007 01:03PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard |
| Scanning Probe - FSP | no | Probe voltage power supplies have been turned off. Pneumatic air supply has been disconnected. | Sep 14 2007 01:03PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard |
| Scanning Probe - WASP | no | Probe voltage power supplies have been turned off. Coil drive power supply has been turned off. | Sep 14 2007 01:04PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick |
| TCI | yes | CO2 Laser is on --- initial alignment complete | Nov 16 2007 01:23PM (irby) | Jim Irby | Two-Color Interferometer | irby,murray |
| TS - Core | no | System is disassembled to allow for manned access. Laser access from the YAG lab is blocked by a physical shutter plate. | Sep 14 2007 12:01PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma |
| TS - Edge | no | System is disassembled to allow for manned access. Laser access from the YAG lab is blocked by a physical shutter plate. | Sep 14 2007 12:02PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma |
| Vispec | yes | 350 and 670 nm, 4 spatial channels | May 04 2007 01:02PM (agraf) | Alex Graf | Visible Spectrometer | agraf |