Alcator C-Mod Run 1071206 Information

Back to runs

Miniproposals
Miniproposal:475
Date Filed: 3/23/2007
Title:Cryopump Startup
First Author:Brian Labombard
Session Leader:Brian Labombard (shots 1-29)

Operators
Session leader(s):Brian Labombard
Physics operator(s):Joseph Snipes
Engineering operator(s):Bill Cochran,Andy Pfeiffer,Ed Fitzgerald

Engineering Operator Run Comment
MP#475: Cryopump Startup - H/D control experiments

Session Leader Plans
Entered: Dec 5 2007 02:51:50:980PM
Author: Brian Labombard
Run Plan for 1071206

MP#475 ""Cryopump Startup"" - H/D control experiments

Goal
Explore cryopump as a tool to control the H/(H+D) concentration in C-Mod discharges.
See if a strong 'puff and pump' scenario can be used to speed-up hydrogen from the vessel.

Plan
We will run some upper null discharges with NL04 ~ 0.9 both with cryopump
warm and cold. With cryopump cold, we will need a gas-fueling assist from
the NINJA system.

Start from USN discharge like 1071204027 (0.8 MA) with NL04 = 0.9.
Set up for 25 PSI D2 in NINJA system with trig: 0.3 duration: 1.0.
Gatevalves closed for 5 minutes after shot.

Run a few shots with and without cryopump. Monitor H/(H+D), look at RGA with
gatevalves closed. Move towards higher currents (1 MA) and densities (Nl04 ~ 1)
and repeat.

Physics Operators Plans
Entered: Dec 5 2007 04:59:21:537PM
Author: Joseph Snipes
Engineering setup for Thursday 06 Dec 2007

MP#475: Cryopump Startup - H/D control experiments

Session leader: B. LaBombard
Physics operator: J. Snipes

ECDC overnight in D2 and bake at 60 C. Stop ECDC by 7:00 am.

Run will start at 09:00 and end at 17:00.

Power systems as on 1071204027

A-coil configuration: +Dtop -Dbot -Jtop +Jbot; Enabled (standard
configuration)

Gas Setup:
fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 25 psi D2 Enabled

Enable the following gate valves and shutters, assuming no vacuum problems:
ECE, VUV, Z-bolo (Do not enable DNB gate valve.)

Torvac setup: gate valves closed after the shot

Specific diagnostics: standard set

-------------------------------------------------------------------------------
ICRF Setup: Turned off for entire run

LH Setup: no

DNB: no

Cryopump: should be ready on the first shot but not pumping
-------------------------------------------------------------------------------
Run plan: start from 1071204027 (0.8 MA, 5.4 T, 0.9e20m-2, upper null) and compare H/D ratio with cryopump off and on. May run 1 MA later in the run at higher density. See session leader run plan for more details.

Session Leader Summaries
Entered: Dec 6 2007 10:23:22:497PM
Author: Brian Labombard
Run Summary for 1071206

MP#475 """"Cryopump Startup"""" - H/D control experiments

The primary goal of the experiments today was to see if we could exert some
control over the H/(H+D) concentrations in a discharge by a combination of
strong gas-puffing and cryopumping. In addition, we wanted to determine if such
'puff and pump' scenarios might help speed up the removal of hydrogen from the
vessel. The approach was simple: run USN discharges with pump on/off, look at
H/(H+D) behavior during the discharge and look at the quantity of hydrogen
recovered in the gas phase after the shot when the gate-valves are closed and
the cryopump has completed its regeneration (if it was used).

We started off by dialing up some USN plasmas to condition the upper divertor
surfaces, 0.8 MA at first then moving to 1.0 MA. It did not take long to get
reproducible USN discharges; by shot #5, good discharges were rolling off the
assembly line regularly. However, the cryopump system developed a problem early
- an ice blockage developed in the helium inlet line in preparation for
shot#2. Neither liquid nor gaseous helium could be sent through the line. We
began heating up the cryogenic lines (LHe and LN2) with room temperature gas
purges in the hope of thawing things out. Around about shot#10 the blockage in
the LHe line started to clear. We managed to get the pump operational for
shot#14. Then another problem became apparent - an intermittent reporting of the
H/(H+D) level due to low signal-to-noise levels. Apparently, Earls spectrometer
does not have a good view of the recycling light in the upper divertor. To
remedy this, we went to 0.8 MA discharges with NL04 ~ 1. These tended to have
bright inner divertor leg D-alpha intensities, resulting in a MARFE that jumped
to near the lower divertor in unpumped discharges. By shot #18, these conditions
led to good H/(H+D) signals in quasi-matched discharges with the pump on and
off. Then we ran many shots alternating between pump on and off, seeing if an
initially observed trend of low H/(H+D) with cryopumping persisted over many
shots. It did. Generally we found that the D2 puffing and pumping (about 130
torr-l injected and recovered) resulted in about a factor of two reduction in
H/(H+D) compared to the unpumped case (with about 30 torr-l injected and
recovered). H/(H+D) levels as low as 4% were observed with puff/pump, which is
remarkable considering that this is just the second run week in the present
campaign. A question that remains is: Did the puff/pump scenario result in
increased hydrogen removal from the vessel? For this we need to look at the RGA
traces of the recovered gas - something to chew on with Jim Irby's help when he
returns.

-- Shot Log --

Shot 14 - 1.0 MA, USN, NL04=0.83
Cryopump cold. 44 torr-l injected. 45 torr-l during regen
no H/(H+D) data, except around 2 seconds.
Shot 15 - 0.8 MA, USN, lost NL04 and feedback, gas valve wide open!
Cryopump cold. 168 torr-l injected. 167 torr-l revcovered during regen
H/(H+D) down to 6%
Shot 16 - Fizzle
Shot 17 - 0.8 MA, USN, NL04~0.77
Cryopump cold. 81 torr-l injected. 72.5 torr-l recovered during regen
H/(H+D) around 8%
Shot 18 - 0.8 MA, USN, NL04~0.95
Cryopump cold. 150 torr-l/s throughput.
139 torr-l injected. 124 torr-l revcovered during regen
H/(H+D) around 5%
Shot 19 - 0.8 MA, USN, NL04~1 and jumps up at .87 s as MARFE moves to bottom.
Cryopump warm. 29 torr-l injected, 28 torr-l recovered.
H/(H+D) around 8.5% before MARFE, then ramps to 12%
Shot 20 - Fizzle
Shot 21 - 0.8 MA, USN, NL04~0.95 and jumps up at 1 s as inner strikepoint MARFE moves to bottom.
Cryopump warm. 28 torr-l injected, 26 torr-l recovered.
H/(H+D) around 11% before MARFE, then ramps to 13%
Shot 22 - 0.8 MA, USN, NL04~0.93
Cryopump cold. 143 torr-l injected, 124 torr-l recovered.
H/(H+D) around 4.5%
Shot 23 - 0.8 MA, USN, NL04~0.94 and jumps up at 1.1 s as inner strikepoint MARFE moves to bottom.
Cryopump warm. 26.5 torr-l injected, 22.5 torr-l recovered.
H/(H+D) around 10%
Shot 24 - 0.8 MA, USN, NL04~0.93
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 140 torr-l injected, 122 torr-l recovered.
H/(H+D) around 4.5%
Shot 25 - 0.8 MA, USN, NL04~0.96, jumps up at 1.1s as MARFE forms on bottom.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 34 torr-l injected, 29.6 torr-l recovered.
H/(H+D) around 9%
Shot 26 - 0.8 MA, USN, NL04~0.96, jumps up at 1.1s as MARFE changes
piezo valve goes wide open 1.27 to 1.38 s for some reason.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 45 torr-l injected, 37 torr-l recovered.
H/(H+D) around 8% ramping to 10%
Shot 27 - Fizzle
Shot 28 - 0.8 MA, USN, NL04~0.94
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 139 torr-l injected, 120 torr-l recovered.
H/(H+D) ramps down to around 4% at 1 s and holds at 4% until 1.5 s
Shot 29 - 0.8 MA, USN, NL04~0.92
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 138 torr-l injected, 122 torr-l recovered.
Again, H/(H+D) ramps down to around 5% at 0.7 s, then 4% at 1 s and holds at 4% until 1.45 s

Physics Operator Summaries
Entered: Dec 6 2007 05:08:58:820PM
Author: Joseph Snipes
Despite some initial difficulties getting the cryopump working properly in the morning, we completed the scientific program of the run and got very good results. See the Session Leaders summary for details. The machine ran very well today with no delays due to main machine components or power systems, though there were data system delays on the first and last shots. There were a total of 29 shots with 25 plasmas and 4 fizzles. All plasmas were full length upper null except for disruptions in the rampdown for the shots without the cryopump. The cryopump was very effective at pumping out the density in the rampdown resulting in very smooth rampdowns and no disruptions in rampdown for shots with the cryopump on. We settled on 0.8 MA and about 0.9 x 10^20 m-2 so as to get MARFES to improve the signal on the H/D ratio measurement, which was essential for the scientific results of this experiment. In general, the H/D ratio was twice as large without the cryopump as with the cryopump on because the extra deuterium puffing required to achieve the same density with the cryopump on dilutes the hydrogen more.

Shot,Duration(s),Ipmax(MA),Result Shot,Duration(s),Ipmax,Result
| 01 1.743 0.809 Plasma | 02 1.691 0.816 Plasma |
| 03 1.696 0.819 Plasma | 04 0.000 0.038 Fizzle |
| 05 1.701 1.006 Plasma | 06 1.804 1.008 Plasma |
| 07 1.835 1.007 Plasma | 08 1.870 1.008 Plasma |
| 09 1.832 1.008 Plasma | 10 1.845 1.009 Plasma |
| 11 1.876 1.008 Plasma | 12 1.906 1.009 Plasma |
| 13 1.955 1.010 Plasma | 14 1.966 1.010 Plasma |
| 15 1.571 0.809 Plasma | 16 0.000 0.052 Fizzle |
| 17 1.967 0.826 Plasma | 18 1.964 0.817 Plasma |
| 19 1.791 0.817 Plasma | 20 0.000 0.054 Fizzle |
| 21 1.771 0.817 Plasma | 22 1.964 0.817 Plasma |
| 23 1.778 0.816 Plasma | 24 1.965 0.819 Plasma |
| 25 1.734 0.814 Plasma | 26 1.711 0.815 Plasma |
| 27 0.000 0.050 Fizzle | 28 1.966 0.823 Plasma |
| 29 1.965 0.817 Plasma
Date 1071206: 29 shots. 25 plasmas. 4 fizzles. 0 duds. 0 System Error.
Total plasma duration: 45.87 s (exceeding -81 kA)

Session Leader Comments
Dec 6 2007 09:54:29:987AM1071206001Brian LabombardShot 1 - 0.8 MA, USN, NL04~1 and dropping
Cryopump off.
18 torr-liters in, 18 torr-liters out
H/(H+D) rising from .06 to 0.12
Dec 6 2007 12:29:11:167PM1071206009Brian LabombardShot 9 - 1.0 MA, USN, NL04=0.86 ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump off.
Probes cleaning up
Dec 6 2007 01:08:26:963PM1071206012Brian LabombardShot 12 - 1.0 MA, USN, NL04=0.86 ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump off. Ice block seems to be cleared.
We will open the LN2 valve and start flow again.
Probes cleaning up.
Dec 6 2007 01:39:18:197PM1071206013Brian LabombardShot 13 - 1.0 MA, USN, NL04=0.83 ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump off.
Probes cleaning up.
No H/(H+D) data!
Dec 6 2007 01:54:31:420PM1071206014Brian LabombardShot 14 - 1.0 MA, USN, NL04=0.83 ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 44 torr-l injected. 45 torr-l during regen
no H/(H+D) data, except around 2 seconds.

Next: go to 0.8 MA, NL04 = 0.8
Dec 6 2007 02:06:43:533PM1071206015Brian LabombardShot 15 - 0.8 MA, USN, lost NL04 and feedback, gas valve wide open.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 168 torr-l injected. 167 torr-l revcovered during regen
H/(H+D) down to 6%

Next: NL04 = 0.9 with feedback control
Dec 6 2007 02:21:16:587PM1071206016Brian LabombardFizzle. 1.3 torr-liters in, 3 torr-liters out
Dec 6 2007 02:32:08:153PM1071206017Brian LabombardShot 17 - 0.8 MA, USN, NL04~0.77
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 81 torr-l injected. 72.5 torr-l revcovered during regen
H/(H+D) around 8%

Next: NL04 = 1.2 with feedback control
Dec 6 2007 02:44:46:720PM1071206018Brian LabombardShot 18 - 0.8 MA, USN, NL04~0.95
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 150 torr-l/s throughput.
139 torr-l injected. 124 torr-l revcovered during regen
H/(H+D) around 5%

Next: try for same NL04 with pump warm.
Dec 6 2007 02:57:10:287PM1071206019Brian LabombardShot 19 - 0.8 MA, USN, NL04~1 and jumps up at .87 s as MARFE moves to bottom.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 29 torr-l injected, 28 torr-l recovered.
H/(H+D) around 8.5% before MARFE, then ramps to 12%

Next: try for slightly lower NL04 with pump warm.
Dec 6 2007 03:21:00:937PM1071206021Brian LabombardShot 21 - 0.8 MA, USN, NL04~0.95 and jumps up at 1 s as inner strikepoint MARFE moves to bottom.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 28 torr-l injected, 26 torr-l recovered.
H/(H+D) around 11% before MARFE, then ramps to 13%

Next: Repeat shot #18 with cryopump cold
Dec 6 2007 03:39:29:850PM1071206022Brian LabombardShot 22 - 0.8 MA, USN, NL04~0.93
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 143 torr-l injected, 124 torr-l recovered.
H/(H+D) around 4.5%

Next: Repeat shot #21 with cryopump warm
Dec 6 2007 03:49:25:027PM1071206023Brian LabombardShot 23 - 0.8 MA, USN, NL04~0.94 and jumps up at 1.1 s as inner strikepoint MARFE moves to bottom.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 26.5 torr-l injected, 22.5 torr-l recovered.
H/(H+D) around 10%

Next: Repeat shot #18 with cryopump cold
Dec 6 2007 04:01:37:717PM1071206024Brian LabombardShot 24 - 0.8 MA, USN, NL04~0.93
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 140 torr-l injected, 122 torr-l recovered.
H/(H+D) around 4.5%

Next: Repeat shot #21 with cryopump warm and bring scanning probes to separatrix.
Dec 6 2007 04:13:04:957PM1071206025Brian LabombardShot 25 - 0.8 MA, USN, NL04~0.96, jumps up at 1.1s as MARFE forms on bottom.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 34 torr-l injected, 29.6 torr-l recovered.
H/(H+D) around 9%

Next: Repeat with probes deeper, again crypump off.
Dec 6 2007 04:30:03:277PM1071206026Brian LabombardShot 26 - 0.8 MA, USN, NL04~0.96, jumps up at 1.1s as MARFE changes
piezo valve goes wide open 1.27 to 1.38 s for some reason.
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump warm. 45 torr-l injected, 37 torr-l recovered.
H/(H+D) around 8% ramping to 10%

Next: Repeat shot #18 with cryopump cold.
Dec 6 2007 04:55:47:630PM1071206028Brian LabombardShot 28 - 0.8 MA, USN, NL04~0.94
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 139 torr-l injected, 120 torr-l recovered.
H/(H+D) ramps down to around 4% at 1 s and holds at 4% until 1.5 s

Next: Repeat
Dec 6 2007 05:25:18:203PM1071206029Brian LabombardShot 29 - 0.8 MA, USN, NL04~0.92
ASP/FSP scanning at 0.7, 0.9, 1.1 s
Cryopump cold. 138 torr-l injected, 122 torr-l recovered.
Again, H/(H+D) ramps down to around 5% at 0.7 s, then 4% at 1 s and holds at 4% until 1.45 s

Physics Operator Comments
Dec 6 2007 09:42:41:260AM1071206001Joseph SnipesShot 1: Reloaded shot 1071205026 for the startup then loaded segment 3 from shot 1071204027 into segment 3 and turned off segment 2 and on segment 3. This is an upper null 0.8 MA, 5.4 T shot with nl04 set to 0.8 x 10^20 m^-2. It seems that the cryopump is always pumping, which may make today's experiment rather difficult. However, I increased the prepuff by 10 ms to 25 ms duration to account for the extra pumping. I also set the argon puff to 100 ms duration and enabled the valve. Good shot.
Dec 6 2007 10:26:25:650AM1071206001Joseph SnipesProblem with the cryopump. Short delay.
Dec 6 2007 10:50:34:443AM1071206002Joseph SnipesShot 2: Repeat. Cryopump off attempting to warm up an ice block in the line. Good shot.
Dec 6 2007 11:01:01:010AM1071206003Joseph SnipesShot 2: Reduce prepuff to 20 ms duration. Good shot.
Dec 6 2007 11:14:52:123AM1071206004Joseph SnipesShot 4: Increased Ip to 1 MA. Reduced prepuff to 17 ms duration. Chamber pressure was very high at breakdown around 8 x 10^-6 Torr, much higher than the previous shots. Fizzle.
Dec 6 2007 11:28:19:490AM1071206005Joseph SnipesShot 5: Try again with no changes to see if the problem repeats itself or goes away. Good shot.
Dec 6 2007 11:41:17:133AM1071206006Joseph SnipesShot 6: Set pre-programmed gas puff in segment 3 to zero after 0.144 s to attempt to get rid of the MARFE. Good shot.
Dec 6 2007 11:53:57:857AM1071206007Joseph SnipesShot 7: Repeat. Good shot.
Dec 6 2007 12:06:57:503PM1071206008Joseph SnipesShot 8: Repeat. Good shot.
Dec 6 2007 12:19:49:163PM1071206009Joseph SnipesShot 9: Repeat. Good shot.
Dec 6 2007 12:32:20:777PM1071206010Joseph SnipesShot 10: Repeat. Good shot.
Dec 6 2007 12:48:14:160PM1071206011Joseph SnipesShot 11: Changed rampdown to attempt to ramp the plasma all the way down. Pushed RCUR a little faster in rampdown against the inner wall. Dropped nl04 negative after 1.5 s. Good shot.
Dec 6 2007 01:02:01:807PM1071206012Joseph SnipesShot 12: Repeat. Good shot.
Dec 6 2007 01:03:50:963PM1071206012Joseph SnipesCell access for cryopump maintenance.
Dec 6 2007 01:25:58:143PM1071206013Joseph SnipesShot 13: Repeat while cryopump begins to cool down. Good shot.
Dec 6 2007 01:43:35:603PM1071206014Joseph SnipesShot 14: Increased prepuff by 10 ms to 27 ms duration to account for the cryopump.
Good shot.
Dec 6 2007 01:58:51:843PM1071206015Joseph SnipesShot 15: Increased prepuff by 5 ms to 32 ms duration. Reduced Ip to 0.8 MA. Gas fault resulted in gas puffing full out during the shot. TCI seems dead. Disrupted at 1.56 s.
Dec 6 2007 02:08:01:127PM1071206016Joseph SnipesShot 16: Repeat with the TCI gate valve open. Also increased nl04 to 9 x 10^19 m^-2. Fizzle! Neutral pressure at 3.5 x 10^-7 just before the shot.
Dec 6 2007 02:19:59:977PM1071206017Joseph SnipesShot 17: Increased prepuff by 5 ms to 37 ms duration. Good shot.
Dec 6 2007 02:32:43:073PM1071206018Joseph SnipesShot 18: Increased prepuff by 3 ms to 40 ms duration. Increased nl04 to 1.2 x 10^20 m^-2. Good shot.
Dec 6 2007 02:46:44:487PM1071206019Joseph SnipesShot 19: Decreased prepuff by to 17 ms duration. Decreased nl04 to 1.0 x 10^20 m^-2. Cryopump warm. Good shot.
Dec 6 2007 02:58:26:223PM1071206020Joseph SnipesShot 20: Reduced nl04 to 0.95 x 10^20 m^-2. Fizzle!
Dec 6 2007 03:11:01:557PM1071206021Joseph SnipesShot 21: Reduced prepuff by 2 ms to 15 ms duration. Good shot.
Dec 6 2007 03:25:15:360PM1071206022Joseph SnipesShot 22: Reloaded shot 18. Cryopump back on. Good shot.
Dec 6 2007 03:36:46:130PM1071206023Joseph SnipesShot 23: Reloaded shot 21. Cryopump off. Good shot.
Dec 6 2007 03:50:19:997PM1071206024Joseph SnipesShot 24: Reloaded shot 18. Cryopump back on. Good shot.
Dec 6 2007 04:03:44:797PM1071206025Joseph SnipesShot 25: Reloaded shot 21. Cryopump off. Good shot.
Dec 6 2007 04:18:48:240PM1071206026Joseph SnipesShot 26: Repeat. Good shot.
Dec 6 2007 04:33:08:527PM1071206027Joseph SnipesShot 27: Reloaded shot 18. Cryopump back on. Fizzle!
Dec 6 2007 04:45:27:233PM1071206028Joseph SnipesShot 28: Repeat. Good shot.
Dec 6 2007 05:08:49:210PM1071206029Joseph SnipesShot 29: Repeat. Good shot.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:40:02:433AMPlasmaOk
210:46:10:363AMPlasmaOk
310:59:18:803AMPlasmaOk
411:12:08:590AMPlasmaOk
511:26:27:253AMPlasmaOk
611:39:35:163AMPlasmaOk
711:52:20:123AMPlasmaOk
812:05:21:567PMPlasmaOk
912:17:54:943PMPlasmaOk
1012:30:30:730PMPlasmaOk
1112:43:14:500PMPlasmaOk
1212:55:58:363PMPlasmaOk
1301:24:22:517PMPlasmaOk
1401:40:13:070PMPlasmaOk
1501:53:13:653PMPlasmaOk
1602:05:53:627PMPlasmaOk
1702:18:15:680PMPlasmaOk
1802:30:58:933PMPlasmaOk
1902:44:02:280PMPlasmaOk
2002:56:45:990PMPlasmaOk
2103:09:08:697PMPlasmaOk
2203:21:48:513PMPlasmaOk
2303:35:05:363PMPlasmaOk
2403:48:32:777PMPlasmaOk
2504:01:08:250PMPlasmaOk
2604:16:58:567PMPlasmaOk
2704:31:31:323PMPlasmaOk
2804:43:43:060PMPlasmaOk
2904:56:12:630PMPlasmaOk

System Availability
Dec 6 2007 09:39:45:997AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDyesFully operationalMar 28 2007 09:19PM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyesvertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm.Feb 06 2007 10:00AM (bravenec)Ron BravenecBeam Emission Spectroscopybravenec
BolometersnoDiode 2pi working fine, foil 2pi still in the same poor condition as last campaign. Midplane AXUV down, fixing problem with AXA. Midplane foils working fine, but need calibration. 2D bolometry is being digitized but need to debug and calibrate gains.Nov 29 2007 01:38PM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoFirst Boronization 5/9/07 Bottle has been removed from the cellSep 14 2007 12:42PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAno Jan 14 2007 02:06PM Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoLN2 manual valve is closed. LHe valve is closed and disconnected from PLC.Sep 14 2007 01:26PM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm.Nov 27 2007 10:21AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,rachmcd,rowan
D Alphayes\ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are availableNov 26 2007 04:23PM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayesoptics repaired, camera re-installed, and view has been re-calibratedNov 27 2007 09:54AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationno Nov 20 2007 10:47PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBno Nov 20 2007 10:47PM (granetz)Robert GranetzDiagnostic Neutral Beambeals,granetz
FRC-ECEyesChs 17-32 working - low freq. mixer being repairedNov 26 2007 11:41AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge is operational and calibrated against G-side MKS on shot#1071127002Nov 27 2007 01:25PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
GPCyesDetectors cooled 12/4. Signals on all but Chs 9. Recalibrated 12/4.Dec 05 2007 09:29AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesDetectors cooled 12/5. Most channels operational.Dec 05 2007 09:30AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPInoNeither the Xpt-view nor the midplane-view camera is operational. Nov 26 2007 04:25PM (terry)Jim TerryGas Puff Imagingterry,zweben
H/DyesShould be operational for the FY08 campaignNov 27 2007 09:54AM (marmar)Earl MarmarH/D Ratiomarmar
Hirex Jryes Mar 06 2007 08:59AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SrnoBe Window has a leak and so the gate valve is closedNov 23 2007 12:50PM (ince)John RiceHigh Resolution X-Rayince,rice
HXRyesSomething might be wrong with channel 26; all others working fine.Mar 23 2007 10:43AM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-AntennanoCoaxial line disconnected from the antennaSep 14 2007 11:24AM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennanocoaxial line disconnected from the antennaSep 14 2007 11:24AM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-AntennanoAntenna is still connected. We will only do transmitter work after the lines are disconnected and capped. Sep 14 2007 11:26AM (ylin)Steve WukitchJ-port antennawukitch,ylin
Lower HybridyesBody I Fault Circuits Repaired and tested. High power tests completedDec 05 2007 06:40PM (dterry)Ron ParkerLower Hybriddterry,parker
LPIno Oct 12 2007 12:41PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphanoMidplane and WB1-LY attached but need to be debuggedNov 20 2007 05:21PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesWorking fine.Nov 29 2007 01:36PM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesWorking, low speed to start out.Dec 04 2007 09:27AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesE-Top, E-Bottom, F-top (cryo), G-side, and B-bottom are operational. F-top gauge has a 'sniffer tube' to measure pressures in cryopump gas box.Mar 20 2007 06:42PM (g)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoInitial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. May 30 2007 08:01PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoWe are basically awaiting the DNB & its new aperture. MSE itself is OK. Two of 10 channels are dead.Nov 20 2007 08:26PM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for the He3 bank. Voltage will be turned on for the global system at the first plasma attempts.Nov 26 2007 08:31AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and Hardsyescalibration unchanged from 2007 campaignDec 04 2007 08:56PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAyesAll capillaries displayed by the NINJA_CONTROL GUI have been tested. Nov 26 2007 04:26PM (terry)Brian LaBombardNINJA gas pufflabombard,terry
PCInoBoth CO2 and HeNe Lasers are disabled----- safe for machine entry.Sep 14 2007 03:21PM (lianglin)Miklos PorkolabPhase Contrast Imagingedlund,lianglin,ntsujii,porkolab
Penning GaugesyesAll gauges except B_DivL are operatingNov 27 2007 01:31PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Nov 26 2007 04:27PM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Probe Array - ISDyesOperationalNov 27 2007 01:40PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperationalNov 27 2007 01:40PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometernoSystem offSep 14 2007 02:46PM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational, but needs to be checked with plasma.Nov 27 2007 01:45PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPnoPneumatic air supply is still disconnected.Nov 27 2007 01:46PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA- and K-port WASP electrodes have been replaced/tested.Nov 27 2007 01:44PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
TCIyesCO2 Laser is on --- initial alignment completeNov 16 2007 01:23PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CorenoSystem is being reassembled following manned access. Availablity during pre-physics phase will be limited.Nov 26 2007 02:58PM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma
TS - EdgenoSystem being reassembled following manned access. Availability will be limited during pre-physics portion of campaign.Nov 26 2007 02:59PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOnoData acquisition upgraded before FY08. Still waiting on engineering network connection to run digitizers.Nov 27 2007 09:16AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke