| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Jerry Hughes |
| Physics operator(s): | |
| Engineering operator(s): | Andy Pfeiffer,Bill Parkin,Gary Dekow |
| Engineering Operator Run Comment |
| MP514: Influence of magnetic topology on the H-mode pedestal SL: Hughes |
| Session Leader Plans |
| Entered: Jan 25 2008 08:19:11:763AM |
| Author: Jerry Hughes |
| This experiment will continue to examine the modification of pedestal
parameters and consequent H-mode performance by modulating magnetic balance. It will follow on work done on 1070821, but will expand to additional values of plasma current and will utilize the cryopump. SETUP: **Overnight boronization: Use most recent recipe **Diagnostics desired Edge and core Thomson, ECE diagnostics, CXRS, bolometer and Lyman-alpha arrays, PCI, reflectometry, Hirex, scanning probes **DNB Would like it, if and only if current can be kept at >5.5A. Fast modulation for CXRS; McDermott should choose the timing. **Gas NINJA plenum loaded with 10psi D2 Argon puff: 50ms at 0.3s (Argon at 1psi) **ICRF 3MW needed by 10:00, flat from 0.6 to 1.5s. First few discharges will be Ohmic, ICRF can use the time after 1.2s for conditioning/boronization recovery. Will want to go to >4MW later in the day. Tentative shot sequence: A. (4 shots) Ohmic SSEP scans to calibrate the magnetic balance. Load shot 1070821015, an 800kA shot with an SSEP scan from -5mm (<1s) to 5mm (@1.25s) and back to -5mm (@1.5s). Change timing of SSEP scan from [1.0, 1.25, 1.5] to [0.6, 0.9, 1.2]. ICRF can run as needed after 1.2s in order to recover from boronization. Cryopump will be warm on these shots. 1. Run this 800kA discharge, with nl04=1e20m-2 2. IP=1.0MA. nl04=1.2e20m-2 3. IP=0.6MA. nl04=8e19m-2 4. IP=0.4MA. nl04=6e19m-2 For each current, determine the best estimate for the offset that should be applied to the SSEP value reported by EFIT, for applying to subsequent shot programming. ***Before proceeding, we will probably want a cell access to adjust edge TS fiber placement.*** B. (16 shots) H-modes with 3MW of ICRF from 0.6s to 1.5s, cryopump cold. SSEP during flattop is to be flat, except for the ramps defined below. Starting SSEP (@t=0.6s) will be -5mm for all discharges. 1. IP=1.0MA. nl04=1.0e20m-2. a. As in part A., ramp SSEP [-5mm --> 5mm] from [0.60s --> 0.90s], then [5mm --> -5mm] from [0.90s --> 1.20s] b. Ramp SSEP [-5mm --> -2mm] from [1.10s --> 1.20s] c. Ramp SSEP [-5mm --> 0mm] from [0.70s --> 0.85s], then [0mm --> 2mm] from [1.10s --> 1.20s] d. Ramp SSEP [-5mm --> 4mm] from [0.70s --> 0.90s], then [4mm --> 6mm] from [1.15s --> 1.25s] 2. IP=0.8MA. nl04=0.8e20m-2. Repeat SSEP scans a--d at this condition. 3. IP=0.6MA. nl04=0.6e20m-2. Repeat SSEP scans a--d at this condition. 4. IP=0.4MA. nl04=0.4e20m-2. Repeat SSEP scans a--d at this condition. C. (5 shots) Return to the most promising low density, low nu* H-mode targets from part B., and apply increased ICRF power. In each of these discharges, there will be only one target SSEP. The ramp will be from -5mm to the target SSEP over [0.7 --> 0.9], after which SSEP will stay flat. ICRF will be a constant 3MW from 0.6--0.9s, ramp to the maximum available power at 1.2s, then hold fixed until 1.5s. D. (5 shots) Repeat some desirable low nu* H-mode targets from parts B. and C. with the cryopump warm. These can be used to evaluate the effectiveness of the pump in lowering the pedestal density. |
| Physics Operators Plans |
| Entered: Jan 23 2008 06:34:08:480PM |
| Author: Ron Parker |
| Physop Run Plan for Tuesday, 25-Jan-2008; 1080125
Purpose: MP514: Influence of magnetic topology on the H-mode pedestal SL: Hughes PO: Parker ----------------- Engineering Setup ----------------- Run begins at 09:00 and ends at 17:00 Power systems as on: 1080123001 Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled Gas setup: Fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1) leave B-side upper as is Hybrid DISABLED (PG2) fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3) fill NINJA with 10 psi D2 DISABLED Enable gatevalves and shutters: ECE, VUV, DNB, Z-bolo Diagnostics: Required: Edge Thomson,ECE, toroidal and poloidal LFS CXRS, inner wall CXRS, TCI, PCI, reflectometry. Desirable: X-ray Ti, rotation diagnostics Torvac gatevalve toggle (yes/no): no Boronization(yes/no): yes, overnight ICRF(yes/no): yes LH(yes/no): no DNB(yes/no): yes if available Cryopump (yes/no): yes, standby Vessel temperature: 35/35/35 Shot setup and sequence: See SL Plan |
| Session Leader Summaries |
| Entered: Jan 25 2008 05:25:59:083PM |
| Author: Jerry Hughes |
| This experiment examined the modification of pedestal parameters and
consequent H-mode performance by modulating magnetic balance, following on work begun on 1070821. The plan was expanded to include additional values of plasma current and use of the cryopump. Despite some minor delays we completed a fair fraction of the run plan. ICRF performed very well today, requiring relatively little time to come to 3MW, despite an overnight boronization. We obtained a fair number of H-mode pedestals in near double null configuration, while modulating the value of SSEP values from -5mm to +5mm. We reproduced the previously observed pump-out of the density pedestal as magnetic balance shifts toward USN, and saw that this trend continued as we went to higher q discharges (Ip=600kA). We had difficulties producing steady EDA-like H-modes at lower q (Ip=1MA), which is consistent with our usual experience, particularly when approaching unfavorable ion grad-B drift direction. Despite the good pump-out for SSEP>0, the collisionality was generally lower for SSEP between about -4mm and -2mm. Our best confinement was achieved in this range of magneitc balance, with relatively high edge beta_pol, and the appearance of high-frequency small ELMs. Several shots were devoted to ohmic SSEP scans, which were used to "calibrate" the value that EFIT gives for SSEP. Based on measurements of divertor neutral pressures, particle fluxes to upper and lower targets, and wide angle video images, it appears that EFIT is calculating SSEP correctly to within about 1mm. |
| Physics Operator Summaries |
| Entered: Jan 25 2008 05:27:10:850PM |
| Author: Ron Parker |
| The run started on time and the shots went off with regularity. One exception occured when there was a problem with the cryopump, traced to a faulty limitswitch. Once repaired, or by passed, the run proceeded without further delays. The physics plan of the run was centered on examining the the dependence of H-Mode parameters and pedestals on magnetic geometry, in particular ssep.
Most of the run plan was accomplished, although many shots ended in disruption particularly at high RF power. Of note is the good reliability of the startup, except just after the crypump was turned off for the last shot. See SL summary for physics progress. Scorecard: 29 plasma attempts, 3 duds (due to cryopump problems), 13 full length shots, 12 disruptions (all but one late enough to provide useful data), 1 fizzle. |
| Session Leader Comments | |||
| Jan 25 2008 10:46:01:320AM | 1080125001 | Jerry Hughes | First shot is on ohmic SSEP sweep at 800kA, cryo WARM.
Shape looks reasonable. Upper strike is in the right place. Left and right gap are relatively large, and growing during the sweep. Ron will try to fix this and repeat shot. Got divertor pressure measurements. Not sure about the probes. Lower plenum pressure begins to drop when SSEP increases through ~-2mm. On the way back down, the upper chamber holds its pressure until SSEP drops through ~-1.5mm. However, calculated flux to outer divertor drops at around 0.74s, when SSEP is close to zero. Next: Repeat with gap change and lower target nl04 to 8e19. |
| Jan 25 2008 09:33:23:673AM | 1080125002 | Jerry Hughes | No plasma. Retry. |
| Jan 25 2008 10:52:03:013AM | 1080125003 | Jerry Hughes | Shot 1 repeated, with right gap kept under better control. Also, the SSEP scan
down was smoother. Pressures are lower because of the lower target density. You can see the lower chamber start to pump out when SSEP crosses thorugh ~-1mm. Outer divertor flux trace suggests DN begins later, at SSEP~2mm. D+E got in >2MW for a late H-mode. Next shot: Raise Ip to 1MA, nl04=1e20. |
| Jan 25 2008 10:00:44:800AM | 1080125004 | Jerry Hughes | No plasma.
Next shot: Retry. |
| Jan 25 2008 10:22:04:683AM | 1080125005 | Jerry Hughes | 1MA, nl04~1.1--1.2e20. Decent shot, plenty of density. Lower chamber begins
to pump out at SSEP~-1mm. Next shot: 600kA, nl04~8e19 |
| Jan 25 2008 10:35:36:777AM | 1080125006 | Jerry Hughes | 600kA, nl04~9e19. Too much density.
Next shot. Lower request to 6e19. |
| Jan 25 2008 10:45:49:210AM | 1080125007 | Jerry Hughes | Cryopump seems to have gone cold unexpectedly. Frank is putting it in shutdown
mode until we really need it. Next shot. Retry. |
| Jan 25 2008 11:04:12:217AM | 1080125008 | Jerry Hughes | 600kA. nl04~6--7e19. Decent shot.
Next: Lets move on to part B., pumped H-modes. Reload shot 3 (ron will try to stabilize the midplane gaps somewhat). Want cryo COLD. Request 3MW ICRF from 0.6 to 1.5s. |
| Jan 25 2008 02:13:01:730PM | 1080125009 | Jerry Hughes | Shot 3 was not loaded. Rather we got the 600kA shot repeated. The left gap
is under better control. The right gap thrashes a bit. Overall not a bad target. Pedestal coverage seems ok. QCM is present, but vanishes when SSEP gets close to +5mm Next: Try to get the 800kA target. |
| Jan 25 2008 02:14:53:357PM | 1080125010 | Jerry Hughes | That was more or less what we wanted. 800kA with a nice SSEP sweep. Gaps look ok.
RF performed admirably. We see the pedestal pump out as we move to USN. PCI shows QCM present throughout the scan, though amplitude and frequency do change. Next: Lower target nl04 to 7e19 and insert periods of flat SSEP. (-5mm, -2mm) |
| Jan 25 2008 12:02:03:987PM | 1080125011 | Jerry Hughes | 800kA, lower target nl04. We got SSEP flats of -5mm and ~0mm. ne,ped seems to be
the same at the SSEP change, but Te (and H-factor) drops. Next shot: New SSEP program. Try for -2mm, 2mm. |
| Jan 25 2008 12:17:14:660PM | 1080125012 | Jerry Hughes | 800kA, lower target nl04. We got SSEP flats of ~ -3mm and ~ +2mm.
Prad rises before the USN phase. Next shot: New SSEP program. Try to raise the SSEP platforms. |
| Jan 25 2008 03:20:27:620PM | 1080125013 | Jerry Hughes | 800kA. We got SSEP flats of ~ 0mm and ~ +4mm.
ne,ped drops in the USN case, as we saw before. No real improvement in performance, though. High H-factor initially, and maybe some ELMs while still in LSN! QCM is present throughout, though weakest when exactly DN. Next shot: We're having cryopump problems. While they try to fix it, repeat shot 10 without RF, no cryo. |
| Jan 25 2008 01:36:12:673PM | 1080125014 | Jerry Hughes | Ohmic shot with SSEP sweep from -5mm to 5mm and back.
At t=0.74--0.76s, The Isats rise abruptly on the probes at the pumping slots, and the lower divertor starts to pump out. EFIT SSEP is going from -0.8mm to +0.7mm during that period. This suggests EFIT is pretty accurate. |
| Jan 25 2008 01:47:41:030PM | 1080125015 | Jerry Hughes | Shot went basically as programmed. Two separate H-modes, nominally at +2mm and
+5mm. Lower density as we go more USN, as before. Confinement is nothing special once we get away from the LSN early in the first H-mode. Prad is high. Next shot: Reload shot 011 and raise Ip to 1MA. |
| Jan 25 2008 01:58:13:637PM | 1080125016 | Jerry Hughes | 3 unpleasantly radiative H-modes. ICRF has trouble with the tune. Let's retry
with full power. Power room access due to a breaker pull. |
| Jan 25 2008 02:05:07:113PM | 1080125017 | Jerry Hughes | Early injection and disruption. |
| Jan 25 2008 02:30:23:343PM | 1080125018 | Jerry Hughes | RF problems. Shot went anyway, and disrupted mysteriously at 1.27.
|
| Jan 25 2008 02:46:04:690PM | 1080125019 | Jerry Hughes | That shot looked better. On the TV, anyway. No data are coming in.
. . . There they are. Clearly higher RF was not the magic bullet we needed for this shot. H-modes are still radiative. The first H-mode has a transiently high H-factor (>1.7), but it quickly degrades. What happens if we slip SSEP quickly after the L-H transition? Next: Repeat shot 13 with 1MA current. |
| Jan 25 2008 03:09:52:827PM | 1080125020 | Jerry Hughes | E-port is unhappy, and cuts out at t=0.64. Two radiative H-modes initiated at
SSEP 0f -4mm and -2mm, and a third dithering H-mode at +4mm. Probably not worth continuing at this condition. Next: Lower Ip to 600kA. |
| Jan 25 2008 03:42:42:850PM | 1080125021 | Jerry Hughes | 600kA. Radiation is much happier. H-mode is maintained until disruption at ~1.3s.
Two distinct pedestal punp-outs, each associated with an SSEP upward jog, are seen at t~0.85s and t~1.2s. SSEP plateaus are at ~0mm and ~+4mm Next shot: Raise SSEP plateaus to bias more USN. |
| Jan 25 2008 03:41:27:660PM | 1080125022 | Jerry Hughes | 600kA. SSEP plateaus of +4mm and +6mm. By the end ne,ped is <1e20 m^-3.
Ends in a disruption, unfortunately. Next shot: Try to lower SSEP plateaus. |
| Jan 25 2008 03:56:08:943PM | 1080125023 | Jerry Hughes | 600kA. Due to a miscommunication, the ZCUR plateaus from shot 21 were raised
instead of lowered, so basically we got a repeat of shot 22. (SSEP of +4, +6) Next shot: Try to lower SSEP plateaus to -2mm, +2mm |
| Jan 25 2008 04:08:14:880PM | 1080125024 | Jerry Hughes | 600kA. near DN through most of the H-mode.
How much boron have we worn off, exactly? Next shot: Go back to 800kA, Try two SSEP plateaus of about -5mm, -2mm. 3MW RF. (Almost a repeat of shot 11.) |
| Jan 25 2008 04:22:50:503PM | 1080125025 | Jerry Hughes | Back to 800kA. Two SSEP plateaus of about -5mm, -2mm. 3MW RF.
Fairly radiative H-modes. Clearly the boronization has deteriorated since shot 11. However, early in the first H-mode, the Te, and ELMy characteristics are pretty similar. Next: Ramp the power up to 4MW and see what happens. |
| Jan 25 2008 04:46:24:440PM | 1080125026 | Jerry Hughes | Interesting shot. Prad got under control at 0.87, and as more RF ramped to
4MW, the H-mode persisted. As the SSEP swept closer to DN, the H-mode recovered back to its original stored energy (albeit with more RF). Next shot: Ramp RF to 5MW instead of 4MW. |
| Jan 25 2008 05:03:13:910PM | 1080125028 | Jerry Hughes | It's looking a lot like the boronization is shot. 5 H-modes with ELM-free
characteristics. SSEP was flat at -5mm. E-port stopped after 1s. NExt shot: Retry with pump WARM. |
| Jan 25 2008 05:09:07:337PM | 1080125029 | Jerry Hughes | No plasma. End of run. |
| Physics Operator Comments | |||
| Jan 25 2008 09:02:50:590AM | 1080125001 | Ron Parker | Good morning! All systems go at 9:00, first shot coming up. |
| Jan 25 2008 09:13:09:230AM | 1080125001 | Ron Parker | Shot 1 started up OK and had the programmed ZCUR, but disrupted at t = 1.2 s. |
| Jan 25 2008 09:27:03:853AM | 1080125001 | Ron Parker | Right gap seems to be too large, reduce by 1 cm on next shot. |
| Jan 25 2008 09:35:13:897AM | 1080125002 | Ron Parker | Shot 2 was a dud, not enough fill gas following disruption.
Increase pulsed gas by 20 ms for next shot. |
| Jan 25 2008 09:56:41:793AM | 1080125003 | Ron Parker | Shot 3 ran well. Next: Moving on to point 2, 1 MA, 1.0e20 m-2. |
| Jan 25 2008 10:17:56:397AM | 1080125004 | Ron Parker | Shot 4 fizzled, way too much gas (X2). |
| Jan 25 2008 10:19:20:650AM | 1080125005 | Ron Parker | Shot 5 ran as programmed. Now we're having fun.
On to shot 3 in run plan, 600 kA, 8e19 m-2. |
| Jan 25 2008 10:33:32:977AM | 1080125006 | Ron Parker | Shot 6 ran well, but density was ~0.9e19 instead of 0.8e19.
Fussy SL! Try again with density programming set at 0.6e19. |
| Jan 25 2008 10:47:54:230AM | 1080125007 | Ron Parker | Shot 7 was a dud, it turned out that cryopump was pumping, although not intended.
Try again, no change in pulsed gas, cryopump off. |
| Jan 25 2008 11:05:17:470AM | 1080125008 | Ron Parker | Shot 8 ran well, producing the requested conditions.
Next: Reload shot 3, cryopump on so pulsed gas pulse up to 38 ms |
| Jan 25 2008 11:24:52:053AM | 1080125009 | Ron Parker | Shot 9 ran, but disrupted. Shot 3 was not loaded as shot called for. |
| Jan 25 2008 11:43:07:887AM | 1080125010 | Ron Parker | Shot 10 ran, but also disrupted at 1.42 s.
Next: Target density decreased to 0.7e20 m-2. Ssep according to shot B2b in Run Plan |
| Jan 25 2008 12:19:05:583PM | 1080125011 | Ron Parker | Shot 11 ran well, as requested. Full length. |
| Jan 25 2008 12:19:40:070PM | 1080125012 | Ron Parker | Shot 12 ran well, full length. |
| Jan 25 2008 12:20:25:307PM | 1080125013 | Ron Parker | Shot 13 ran well, good shot. Cryopump not pumping as well as it did earlier. |
| Jan 25 2008 12:50:29:730PM | 1080125014 | Ron Parker | Shot 14 was an Ohmic shot, taken while waiting for cryopump repairs. |
| Jan 25 2008 01:30:37:493PM | 1080125014 | Ron Parker | Cryopump is repaired. Shot 15 will be with cryo on. |
| Jan 25 2008 01:38:06:097PM | 1080125015 | Ron Parker | Shot 15 ran full length. Double H-Modes. |
| Jan 25 2008 01:50:53:770PM | 1080125016 | Ron Parker | Shot 16 ran full length, triple H-Modes. |
| Jan 25 2008 01:58:20:103PM | 1080125016 | Ron Parker | Short delay while the cause of a breaker pulling out is investigated. |
| Jan 25 2008 02:06:37:770PM | 1080125017 | Ron Parker | Shot 17 had an early disruption -- 28 ms. |
| Jan 25 2008 02:16:23:720PM | 1080125018 | Ron Parker | The shot will be a no-power shot. |
| Jan 25 2008 02:29:43:407PM | 1080125018 | Ron Parker | Only kidding, shot 18 was run with full Plasma power but without ICRF.
Shot disrupted at 1.28 s. |
| Jan 25 2008 02:33:46:957PM | 1080125019 | Ron Parker | Well, shot ran (full length, I think) but data not coming up.
|
| Jan 25 2008 02:38:16:277PM | 1080125019 | Ron Parker | Shot 19 data came up. Periodic H modes. |
| Jan 25 2008 02:47:14:960PM | 1080125019 | Ron Parker | Shot 19 ran full length. Next: Reload shot 13 and set current to 1 MA. |
| Jan 25 2008 02:57:31:843PM | 1080125020 | Ron Parker | Shot 20 ran full length, triple H-modes. |
| Jan 25 2008 03:07:23:357PM | 1080125020 | Ron Parker | Next: repeat shot 20, lower current (600 kA) |
| Jan 25 2008 03:11:23:843PM | 1080125021 | Ron Parker | Shot 21 ran well until t ~ 1.35 ms, then disrupted. |
| Jan 25 2008 03:43:37:553PM | 1080125022 | Ron Parker | Shot 22 ran well until disrupting at ~ 1.3 ms. |
| Jan 25 2008 03:55:54:130PM | 1080125023 | Ron Parker | Shot 23 was OK, disrupted again at ~ 1.4 s. |
| Jan 25 2008 04:07:05:503PM | 1080125024 | Ron Parker | Shot 24 looked pretty much the same, disrupting at ~ 1.3 s.
For shot 25, return to shot 11 with less ramp in ZCUR. |
| Jan 25 2008 04:23:10:210PM | 1080125025 | Ron Parker | Shot 25 ran well, full length. Next: Same shot, more ICRF power. |
| Jan 25 2008 04:30:32:157PM | 1080125026 | Ron Parker | Shot 26 ran, but disrupted at ~ 1.3 s. Next: same shot, more RF power. |
| Jan 25 2008 04:40:55:027PM | 1080125027 | Ron Parker | Shot 27 disrupted again |
| Jan 25 2008 05:01:15:363PM | 1080125028 | Ron Parker | Shot 28 disrupted, but made it to 1.55 s.
Next and last: Same shot, no cryopump. |
| Jan 25 2008 05:30:29:037PM | 1080125029 | Ron Parker | Shot fizzled, probably due to cryo having been turned off after shot 28. Pulsed gas pulse was reduced to 18 ms (from ~ twice that with cryo) and H alpha had normal peak, but shot fizzled anyway. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:02:47:043AM | Plasma | Ok | |
| 2 | 09:27:08:167AM | Plasma | Ok | |
| 3 | 09:39:38:243AM | Plasma | Ok | |
| 4 | 09:56:04:217AM | Plasma | Ok | |
| 5 | 10:08:36:823AM | Plasma | Ok | |
| 6 | 10:22:31:247AM | Plasma | Ok | |
| 7 | 10:35:19:230AM | Plasma | Ok | |
| 8 | 10:48:53:400AM | Plasma | Ok | |
| 9 | 11:08:15:690AM | Plasma | Ok | |
| 10 | 11:21:59:753AM | Plasma | Ok | |
| 11 | 11:41:57:510AM | Plasma | Ok | |
| 12 | 12:02:06:643PM | Plasma | Ok | |
| 13 | 12:15:25:767PM | Plasma | Ok | |
| 14 | 12:47:21:727PM | Plasma | Ok | |
| 15 | 01:34:45:733PM | Plasma | Ok | |
| 16 | 01:47:35:373PM | Plasma | Ok | |
| 17 | 02:02:01:263PM | Plasma | Ok | |
| 18 | 02:14:32:763PM | Plasma | Ok | |
| 19 | 02:30:46:800PM | Plasma | Ok | |
| 20 | 02:54:29:763PM | Plasma | Ok | |
| 21 | 03:07:56:717PM | Plasma | Ok | |
| 22 | 03:28:06:457PM | Plasma | Ok | |
| 23 | 03:44:27:757PM | Plasma | Ok | |
| 24 | 03:56:54:117PM | Plasma | Ok | |
| 25 | 04:09:23:770PM | Plasma | Ok | |
| 26 | 04:24:00:040PM | Plasma | Ok | |
| 27 | 04:38:26:103PM | Plasma | Ok | |
| 28 | 04:53:55:590PM | Plasma | Ok | |
| 29 | 05:06:24:833PM | Plasma | Ok | |
| System Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Jan 25 2008 09:02:27:263AM | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||