Alcator C-Mod Run 1080214 Information

Back to runs

Miniproposals
Miniproposal:523
Date Filed: 1/23/2008
Title:Effect of Lower Hybrid Current Drive on Rotation profile
First Author:Alex Ince-Cushman
Session Leader:Alex Ince-Cushman (shots 1-18)

Operators
Session leader(s):Alex Ince-Cushman
Physics operator(s):Steve Wolfe
Engineering operator(s):Bill Parkin,Andy Pfeiffer,Ed Fitzgerald

Engineering Operator Run Comment
MP 523: Effect of Lower Hybrid Current Drive on Rotation Profile Sessio

Session Leader Plans
Entered: Feb 13 2008 03:06:43:210PM
Author: Alex Ince-Cushman
MP 523: Effect of Lower Hybrid Current Drive on Rotation Profile

Session Leader: Alex Ince-Cushman
PhysOp: Steve Wolfe

The goal of this experiment is to conduct a LH phase scan at fix power, to see the effect of LHCD on rotation profile evolution.

Diagnostics: Hirex-sr, Thomson, Edge Thomson, Bolometer arrays, McPherson, PCI, Hard X-ray Camera

Step 1: Locked mode discharge for Hirex-Sr calibration (2 shots)
- Repeat discharge 1080116016

Step 2: Reproduce trophy shot of LH induce rotation (1-2 shots)
- shot 1080123022
- LH phase of 90, start at 0.8s for 500ms

Step 3: Repeat baseline shot with no LH (1-2 shots)

Step 4: Phase Scan
- Perform phase scan at: 60, 90, 120 (4-5 shots)
- Cell access: Switch LH hardware for phasing from -120 to -60
- Perform phase scan at: -60, -75, -90, -120 (5-6 shots)
- Cell access: Switch LH hardware for phasing from 150 to 210
- Perform phase scan at: 150, 180, 210 (4-5 shots)

Physics Operators Plans
Entered: Feb 13 2008 04:11:53:050PM
Author: Steve Wolfe
-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Power systems as on: 1080123022

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gatevalves and shutters: ECE, VUV, Z-bolo

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes
ICRF(yes/no): no
LH(yes/no): yes
DNB(yes/no): no
Cryopump (yes/no): no

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters (if requested)
------------------------------
gas and pressure: D2 at 2e-4 Torr
sweep: 44/45/103 cm
scan: 20/120 s

Run Plan:
---------

Start with a locked mode fiducial based on 1080116016
Then run LHCD target 1080123022; same target all day, just LH changes.

Session Leader Summaries
Entered: Feb 14 2008 08:52:43:430PM
Author: Alex Ince-Cushman
MP 523: Effect of Lower Hybrid Current Drive on Rotation Profile

The locked mode portion of the experiment was successful. Two steady locked mode discharges were obtained (Shots 1 & 2) with sufficient argon levels to provide a good wavelength calibration for Hirex-Sr.

Due to a combination of problems with data acquisition, power supplies and lower hybrid electronics, we were only able to complete the co-current portion of the Lower Hyrbird phase scan. A total of 18 discharges were attempted, 13 of which generated a plasma. Below is a summary of the LH phases for which data was obtained.

Phase shot
60 9
90 3
105 13
120 14

For a variety of reasons shots 6, 11, 12 & 17 did not couple any LH power. For the militant optimist, these can be thought of as a collection of fiducial shots. We will attempt to finish the MP during tomorrows run.

Physics Operator Summaries
Entered: Feb 14 2008 05:58:53:100PM
Author: Steve Wolfe
Physop Summary for Thurs Feb 14, 2008. 
MP#523 LHCD Rotation effect
SL: Ince-Cushman
PO: wolfe
EO: Parkin, Pfeiffer, Fitzgerald

We got half a day of running and half a day of sitting/running around. 
Completed through the first phase scan of the run plan 
with mech phase shifters at 90 (co-current). After shot 14,
the phase shifters were changed to counter-current drive, but
we only got one more plasma shot, and the LH failed to fire
on that one, so no data on the second phase scan. This experiment
to be continued (again), preferably after the SL makes an acceptable
offering to the plasma gods. 

No real chanllenges for the physop today. The locked mode shots
were successfully accomplished (#1,2), and once we moved on 
to the LH portion of the run the only seg2 change was a tiny
tweak on the target density. I made a number of adjustments 
to PG4 to try to keep the runaways at bay, with some success
and no disasters. There were a few unusual events:

After shot#2 there was an oh2L fault indication that had to be 
reset in the power room. On shot#3 the OH2L current went up
by nearly 1kA from it's normal value, and the Br0 was low
by 1mT, but the plasma went anyway. This did not recur. 

Shot#5 was a dud because there was no gas puff. Apparently
the HV enable did not come on in PULSE. This did not recur. 

Before shot#9 Alex had to go into the cell to reboot the computer
that runs the hirex_sr system because some Linux daemon was 
running amuck and eating all its memory, preventing the arm
command from operating. 

Shot#10 was a fizzle because the EF1's failed to commutate. Engineers
found a datalink error, which they reset successfully. This did not
recur. 

After shot#14, during the cell access to change the phase shifters,
it was found that five fuses were blown in TF converter#1. Bill 
Cochran determined the cause of the recent problems with this 
converter and changed out a string of gate drive boards. This took
a couple of hours, including the PLC TF test to verify the supply
was working (#15). 

Shot#16 was our first data system problem. INIT completed instantly,
without doing any actions. Took a no power shot. 

Shot#17 was a good plasma, but the LH control system failed to fire. 
It took Atma and Josh nearly two hours to sort this out. Once that
seemed to be working, we tried shot#18, but the data system hung
in INIT and we had to take another no power shot. The last shot, 
taken after 17:00, was also shot#18, but second time was not the 
charm. OH1 and the EF1's failed to fire, for unknown reasons. 
No faults on the PLC or on the supplies. It was probably related
to the no power cycle on the first try at 18, but couldn't figure
out how. 

Scorecard:
----------

    No power shots        2 (but one didn't register)
    Tests                 1
    Duds                  2*(one no gas, one no OH1,EF1's)
    Fizzles               1 (EF1's didn't commutate)
    Plasmas              13*
    =========            ==
    Shots                18+ 1 that didn't count 
 
* Note that Ian's routine doesn't find the good shot on #17
or the dud on 18 because #16 was a no power that didn't have 
data (or a tree), which his algorithm takes to be the end 
of the run. 


Session Leader Comments
Feb 14 2008 09:24:27:873AM1080214001Alex Ince-CushmanGood locked mode discharge. Argon signal levels are lower than we would like and so we will repeat the discharge with a longer puff.
Feb 14 2008 09:50:08:233AM1080214002Alex Ince-CushmanAnother good locked mode discharge. Argon signal levels are sufficient and so we will move on to the Lower Hybrid part of the run plan.
Feb 14 2008 11:39:04:017AM1080214003Alex Ince-CushmanThis shot was a recreation of the LH trophy shot 1080123022. The LH induced a change in rotation of about -25km/s. For the next discharge we will turn off the LH and keep everything else the same.
Feb 14 2008 10:11:48:380AM1080214004Alex Ince-CushmanThere was a problem with Hirex-Sr data acquisition and so we will have to redo the shot.
Feb 14 2008 10:32:18:687AM1080214006Alex Ince-CushmanThis shot will provide us with a great LH on/off comparison with shot 3. We will now begin the LH phase scan starting at 60 degrees.
Feb 14 2008 11:34:48:243AM1080214008Alex Ince-CushmanThere was a problem with one of the Hirex-Sr computers which prevented data acquisition. A cell access was required to manually reboot the misbehaving computer.
Feb 14 2008 11:40:40:797AM1080214009Alex Ince-CushmanThe problem seems to have been resolved. The Lower hybrid ran well at 60 degree phasing and induced a -30km/s change in rotation. For the next shot we will go to 120 degrees.
Feb 14 2008 12:30:56:567PM1080214012Alex Ince-CushmanThe lower hybrid did not couple well. We will try going to 105 phasing and slightly adjusting the density and LH position.
Feb 14 2008 12:46:29:040PM1080214013Alex Ince-CushmanThe LH coupled well at 105 and induced a change in rotation of ~18km/s. We will now try going to 120 phasing.

Physics Operator Comments
Feb 14 2008 07:20:30:873AMSteve Wolfe
Setting up for LH/rotation experiment MP#523 (Ince-Cushman)
Use startup segment from yesterday 1080213033 (in model)
Import seg2 from 1080123022:
 This is a low density (nl04=3e19/m^2), 750kA, LSN with a funny
 jog of a few mm in RXL between .3 and 1sec. SSEP control is off,
 ZCUR=-9mm, Clearin=0
Import seg3 from seg3 of 1080116016 (locked mode shot)
  800kA, LSN, nl04=5e19 dropping negative after 0.7sec, Acoil=4kA,
   b21_proj off.
In seg 1, put Br_0 back from -.0005 to 0.; leave PG4=20msec
Turn off dpcs_ftae2 

Turn off seg2, turn on seg3 (start with LM shot)
Build, load
Load at 14-Feb-2008 07:19:35.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done


Feb 14 2008 09:17:04:270AM1080214001Steve Wolfe
Shot#1: Locked mode plasma for rotation calibration
plasma disrupts at 1.62 in rampdown.
locked mode around 0.68s (ece, nl, ch diff)

Very late breakdown, >10ms. pressure looks very low .038

Next: repeat with 200ms Argon pulse. 

Feb 14 2008 09:47:25:700AM1080214003Steve Wolfe
Shot#2: repeat with 200ms Argon pulse. 
raise pg4 from 20->25ms
Delay for cooling and to check SCR's in oh2l before this shot.
plasma to 1.6 sec, locked mode ~.68sec
breakdown back at 5.5msec, bur Br_0 is very negative, <-.001
OH2L is about 1kA more negative on this shot than on #1:
  shot   oh2u   oh2l
  ----- ------  -----
    1     26.6   25.9
    2     26.6   26.6

Need to keep an eye on this

Turn on seg2 and increase Argon puff from 125 to 200ms

Feb 14 2008 09:53:14:970AM1080214003Steve Wolfe
Shot#3: Turn on seg2 (from 1080123022) and 
   increase Argon puff from 125 to 200ms. LH will fire on this shot
plasma with LH, full length
Br0 looks back to normal. breakdown still ok
OH2L current back down to ~26.0 
Looks like rotation is seeing the effect. 

Next: repeat with no LH


Feb 14 2008 10:04:51:500AM1080214004Steve Wolfe
Shot#4: repeat with no LH
plasma full length, small runaway burst early.
slight bounce in startup, need to start raising pg4. 

next: pg4 from 25 to 28ms

Feb 14 2008 10:19:57:017AM1080214005Steve Wolfe
Shot#5: repeat with no LH (lost HIREX data on #4)
pg4 from 25 to 28ms

dud- No gas. No voltage on any piezo. No faults showing,
everything was enabled. DPCS outputs are there in the interface
room. 


Feb 14 2008 10:28:31:183AM1080214006Steve Wolfe
Shot#6: repeat with no LH (lost HIREX data on #4)
pg4 from 25 to 28ms (if we get gas this time)

plasma full length still some early runaways on the TV
still bouncing in startup. 

Next: raise pg4 some more. Probably LH back on.


Feb 14 2008 10:45:07:500AM1080214007Steve Wolfe
(
Shot#7: repeat with LH 
pg4 from 28 to 32 ms
Load at 14-Feb-2008 10:29:51.00
plasma full length, got LH
no bounce, no early runaways; P0 is up to .075mTorr at t=0.
breakdown is late, around 10ms again. Br0 looks ok; starts at 0.
maybe I should drop it a little? 
Looks like Hirex lost data again. 

Next shot: repeat, leave startup alone and see what happens

Feb 14 2008 10:59:20:250AM1080214008Steve Wolfe
Shot#8: repeat 
plasma with LH
breakdown back at 5.8msec, no bounce, no early runaways.
looks like hirex_sr is still losing data. That's a drag!

Alex is going to have to arm his modules manually for 
each shot. 
Next: repeat

Feb 14 2008 11:21:20:307AM1080214008Steve Wolfe
Shot#9: repeat 
Delay for a cell access to reboot the dec010 computer
that runs the hirex_sr diags. It seems to be running a 
memory-bound process called zmd, which I find in google to
be a SUSE-Linux/Novell thing called the Zenworks Management Daemon.
There are flames about it and how to remove it on the web. 

Feb 14 2008 11:34:23:023AM1080214009Steve Wolfe
Shot#9: repeat 
plasma with LH
bad bounce on startup, almost lost it.
small runaway burst, not visible on scale of hards during and
after LH. 

Hirex_sr has data, they'll move on to next phase in the scan

Next: raise pg4 3ms

Feb 14 2008 11:52:22:503AM1080214010Steve Wolfe
Shot#10:pg4 from 32 to 35ms
Load at 14-Feb-2008 11:35:23.00
fizzle. Probably raise pg4 too much. 
Or not enough, still seems to hit on the way out. 
Did EF1 commutate? NO they didn't.

Next: Power room access to investigate 

Feb 14 2008 12:14:41:407PM1080214011Steve Wolfe
Shot#11: turn on dpcs_ftae2 for Jason (cleared with Alex)
 Load at 14-Feb-2008 12:03:23.00
No change in pg4, since I'm blaming the EF1 comm failure
for the last fizzle. Andy and Gary report a data link malfunction
that has been reset. 

Plasma, No LH? At least no hard xrays. Greg says high reflection
at this phasing. 

Next: LH working? 


Feb 14 2008 12:26:53:830PM1080214012Steve Wolfe
Shot#12: repeat with better LH; they're moving grill in.
plasma with LH. That looks better. No obvious current drive 
though. also no obvious rotation effect. Well, there were
xrays, but the LH mostly retries and faults.

Next: ? Try again?


Feb 14 2008 12:45:10:757PM1080214013Steve Wolfe
Shot#13: raise nl04 from 3.0 to 3.6e19
drop pg4 from 35 to 34msec
Load at 14-Feb-2008 12:31:39.00

plasma, lots more xrays that time. 
density overshot a little, got 4e19 instead of 3.6
If they complain I'll back it down; valve is barely
opening. The extra density is coming from the LH when it stays on.
This shot LH stays on at 400kW. 
This was a late breakdown again, 9msec
fields look ok, rcur a little slow but no pause. 
Zmeter trace is looking noisy. 

Next: drop pg4 another msec?

Feb 14 2008 01:09:06:550PM1080214014Steve Wolfe
Shot#14: pg4 from 34 to 33msec
Load at 14-Feb-2008 12:42:22.00
plasma with LH 
breakdown back at 6msec, current rise looks ok.

Next: switch to counter current drive. Cell Access.
Meanwhile, there are at least five fuses blown in the TF converter
#1. Will need to be changed out. 

Feb 14 2008 01:22:09:487PM1080214014Steve Wolfe
There will be a delay of 45 minutes to an hour in order
to repair the TF power supply. After that, there will be
a PLC TF-only test shot before we resume  plasma operation.

Those who want to go to lunch, now would be a good time.



Feb 14 2008 02:24:13:963PM1080214015Steve Wolfe
Shot#15: PLC TF-only test


Feb 14 2008 02:33:04:083PM1080214015Steve Wolfe
Shot#16: Back to trying for plasma with counter-current LHCD
There has been a power glitch and/or UPS fault in the power room.
One more Power room access to check/reset.


Feb 14 2008 03:02:10:663PM1080214015Steve Wolfe
Shot#16: Back to trying for plasma with counter-current LHCD
It's been over two hours since we had a plasma shot. Vessel
temp is now back up to 26C (had been down around 15C I think).
I should probably do something to the gas, but since I don't know
what, I won't. 

INIT didn't do anything before going green. This shot probably 
isn't going to happen. 


Feb 14 2008 03:18:00:650PM1080214017Steve Wolfe
Shot#17: Still trying for the first counter-current drive shot. 
No PCS changes. Shot#16 never happened, but Pat thinks this 
should be 17, so it is. 

Plasma ok, didn't look like lower hybrid ran. 

Next: Try again, we got nothing better to do.




Feb 14 2008 03:39:41:050PM1080214017Steve Wolfe
Shot#18: Still trying for the first counter-current drive shot. 
No PCS changes. 
Cell Access for LH to reboot a crate




Feb 14 2008 04:53:13:090PM1080214018Steve Wolfe
Shot#18: Still trying for the first counter-current drive shot. 
No PCS changes. 
Brock has permission to try to shoot a small pellet at 1.6sec.
Over an hour since the last shot, LH control system problem 
resolved by Josh and Atma. Vessel back up to 29C. 
Except now it hangs in INIT!!

NO POWER SHOT



Feb 14 2008 05:21:06:247PM1080214018Steve Wolfe
Shot#18 (2nd time): One last try, if Josh can get the data system to 
work again. 

No oh1 or ef1's = DUD. 

END OF RUN

Engineering Operator Comments
ShotTimeTypeStatusComment
109:09:47:043AMPlasmaOk
209:34:22:747AMPlasmaOk
309:47:21:417AMPlasmaOk
409:59:55:243AMPlasmaOk
510:12:24:290AMPlasmaBadNo gas, there was no PLC, HV enable
610:24:55:133AMPlasmaOk
710:37:18:270AMPlasmaOk
810:49:57:253AMPlasmaOk
911:30:12:487AMPlasmaOk
1011:42:47:757AMPlasmaBadEF1 commutation data link fault
1112:08:36:260PMPlasmaOk
1212:20:55:603PMPlasmaOk
1312:34:22:510PMPlasmaOk
1412:46:58:943PMPlasmaOk
1502:21:13:333PMTestOkTF 50 KA
1703:11:45:987PMPlasmaOk
1804:51:26:850PMPlasmaBadEF1 and OH's did not fire, no explantion

System Availability
Feb 14 2008 09:09:28:077AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDyesFully operationalMar 28 2007 09:19PM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyesvertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm.Feb 06 2007 10:00AM (bravenec)Ron BravenecBeam Emission Spectroscopybravenec,rowan
BolometersyesDiode 2pi working fine, foil 2pi being low-pass filtered to remove noise. Outboard miidplane AXUV fine. Midplane foils working fine, but need to fill tree with calibrations. 2D AXUV arrays are being digitized but need further debugging and calibration.Dec 19 2007 07:16PM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoFirst Boronization 5/9/07 Bottle has been removed from the cellSep 14 2007 12:42PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAyesSingle channel CNPA available as of 12/1707Dec 17 2007 05:48PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesCryopump is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm.Nov 27 2007 10:21AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,rachmcd,rowan
D Alphayes\ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are availableNov 26 2007 04:23PM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayesoptics repaired, camera re-installed, and view has been re-calibratedNov 27 2007 09:54AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationno Nov 20 2007 10:47PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBno Nov 20 2007 10:47PM (granetz)Robert GranetzDiagnostic Neutral Beambeals,granetz
FRC-ECEnoProblem with LO'sJan 10 2008 01:17PM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge is operational and calibrated against G-side MKS on shot#1071127002Nov 27 2007 01:25PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
GPCyesAll 9 channels operational as of new year.Jan 03 2008 09:31AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jan 02 2008 12:22PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPInoNeither the Xpt-view nor the midplane-view camera is operational. Nov 26 2007 04:25PM (terry)Jim TerryGas Puff Imagingterry,zweben
H/DyesShould be operational for the FY08 campaignNov 27 2007 09:54AM (marmar)Earl MarmarH/D Ratiomarmar
Hirex Jryes Mar 06 2007 08:59AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SrnoBe Window has a leak and so the gate valve is closedNov 23 2007 12:50PM (ince)John RiceHigh Resolution X-Rayince,rice
HXRyesSomething might be wrong with channel 26; all others working fine.Mar 23 2007 10:43AM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesavailable (quarter-wave transformer for pre-matching)Dec 11 2007 09:01AM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesavailable (with FFT for automatical matching)Dec 11 2007 09:01AM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesnormally in [0,pi,pi,0] phase for heating. current drive phase available if requested.Dec 11 2007 09:03AM (ylin)Steve WukitchJ-port antennawukitch,ylin
Lower HybridyesBody I Fault Circuits Repaired and tested. High power tests completedDec 05 2007 06:40PM (dterry)Ron ParkerLower Hybriddterry,parker
LPIyes1/9/08Jan 09 2008 03:23PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane working fine, emissivity profiles being stored in tree, but still need to apply in-vessel calibrations to data. WB1-LY being digitized, but not processed in tree.Dec 09 2007 06:53PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesWorking fine.Nov 29 2007 01:36PM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesWorking, moderate speed for now.Jan 02 2008 01:19PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesE-Top, E-Bottom, F-top (cryo), G-side, and B-bottom are operational. F-top gauge has a 'sniffer tube' to measure pressures in cryopump gas box.Mar 20 2007 06:42PM (g)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoInitial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. May 30 2007 08:01PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoWe are basically awaiting the DNB & its new aperture. MSE itself is OK. 5 photo detectors have been shipped out for repair, so currently only 5 channels are available. We expect the full channels will be available late in Jan 08.Jan 04 2008 01:11PM (jinseok)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for the He3 bank. Voltage will be turned on for the global system at the first plasma attempts.Nov 26 2007 08:31AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and Hardsyescalibration unchanged from 2007 campaignDec 04 2007 08:56PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAyesAll capillaries displayed by the NINJA_CONTROL GUI have been tested. Nov 26 2007 04:26PM (terry)Brian LaBombardNINJA gas pufflabombard,terry
PCInoBoth CO2 and HeNe Lasers are disabled----- safe for machine entry.Sep 14 2007 03:21PM (lianglin)Miklos PorkolabPhase Contrast Imagingedlund,lianglin,ntsujii,porkolab
Penning GaugesyesAll gauges except B_DivL are operatingNov 27 2007 01:31PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Nov 26 2007 04:27PM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Probe Array - ISDyesOperationalNov 27 2007 01:40PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperationalNov 27 2007 01:40PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
Reflectometeryes50, 60, 75 and 88GHz channels are connected and being tested for the campaignDec 18 2007 10:28AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational, but needs to be checked with plasma.Nov 27 2007 01:45PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesFSP is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA- and K-port WASP electrodes have been replaced/tested.Nov 27 2007 01:44PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
TCIyesCO2 Laser is on --- initial alignment completeNov 16 2007 01:23PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes8 polychromators, 1 laser. Density is calibrated for YAG2. YAG1 is not calibrated yet. Jan 17 2008 11:51PM (yma)Jerry HughesCore Thomson scatteringjwhughes,yma
TS - EdgeyesSystem is working. Density is derived with last year's calibration, and should be good to within ~20%. Jan 18 2008 07:27AM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyessystem operationalJan 10 2008 11:41AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke