Alcator C-Mod Run 1080410 Information

Back to runs

Miniproposals
Miniproposal:537
Date Filed: 2/21/2008
Title:Momentum impulse from rapid ssep changes
First Author:Kenneth Marr
Session Leader:Kenneth Marr (shots 1-26)

Operators
Session leader(s):Kenneth Marr
Physics operator(s):Steve Wolfe
Engineering operator(s):Bill Parkin,Ed Fitzgerald,Gary Dekow

Engineering Operator Run Comment
MP#537 Momentum impulse from rapid ssep changes SL: K. Marr PO: wolfe

Session Leader Plans
Entered: Apr 9 2008 05:02:06:720PM
Author: Kenneth Marr
The goal of this run is to track the changes in momentum through the pedestal as the plasma is jogged vertically up and down. This vertical jog creates a change in SSEP pushing the plasma from LSN to USN and back. The same shot will be repeated several times to collect data from multiple diagnostics and then we will move to a new gap and repeat again. Then if there's time we'll change the current in order to change the temperature of the pedestal and see if that affects the transport of moment.


Overnight ECDC
100ms Argon
Fast EFIT at 0.7s and 1.1s
Cryopump on to maintain density during sweep.
Utilize reduced cooling method as necessary
No RF

A. Ip = 0.8MA nl_04 = 8.0e19m-2, lgap = 10mm
Load shot from 1080314009
Maintain 1cm left gap. Compensate for shift in Lgap at sweeps with a forced
gap reduction/increase?

CXRS in Kinetics mode.

Repeat shot for:
Cases 1 â?? 3
6 shots to optimize signal and timing. Should be enough to get probe participation in LSN portion of the shot.

Cases 4-6
5 shots

If DNB: Cases 7-9
5 shots

Consider returning to Frame Transfer Mode and repeat shot a final time (1 shot)

B. Ip = 0.8MA nl_04 = 8.0e19m-2 lgap = 7mm
Repeat A. but put the IW gap at 7mm rather than 10. The location that
shows little velocity change with the ssep sweep might be fixed in space or a
fixed distance from the separatrix. (10 shots â?? Kinetics; 5 shots Frame Transfer)

C. Ip = 1.0MA nl_04 = 8,0e19m-2 lgap = 10mm
Drive hotter plasmas to explore the effect of pedestal temperature on the
momentum transport. (10 shots including probes.)

If there's still time
D. Ip = 0.6MA nl_04 = 8,0e19m-2 lgap = 10mm
Similar to C. (8 shots including probes)

Change density to change the momentum
E. Ip = 0.8MA nl_04 = 1e20 m-2
F. Ip = 1.0MA nl_04 = 1e20 m-2

Physics Operators Plans
Entered: Apr 9 2008 10:35:59:020AM
Author: Steve Wolfe
Physop plan for Thursday, April 10, 2008
MP#537 Momentum impulse from rapid ssep changes
SL: K. Marr
PO: wolfe

Run starts at 09:00, ends at 17:00
Note: CRYOPUMP requested starting on first shot.
We will need a working RGA to keep track of possible leaks.

-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Power systems as on: 1080314009

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gatevalves and shutters: ECE, VUV, DNB, Z-bolo

Torvac gatevalve toggle (yes/no): NO

Boronization(yes/no): no
Overnight ECDC (yes/no): yes
ICRF(yes/no): no
LH(yes/no): no
DNB(yes/no): yes
Cryopump (yes/no): yes, ON for first shot

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters (if requested)
------------------------------
gas and pressure: D2 at 2e-4 Torr
sweep: 44/45/103 cm
scan: 20/120 s

PCS plan
---------

Start from 1080314009, with timing of sweeps modified per SL_PLAN.
Change density, gaps, etc. per SL_PLAN (once it gets posted).

Session Leader Summaries
Entered: Apr 10 2008 07:07:51:490PM
Author: Kenneth Marr
The run today explored the effect of the SSEP sweep as a continuation of MP537 which ran on 3/14/08 as well (for a very limited number of shots). Today's run went much better in terms of reproducible plasmas. The morning was spent trying to collect sufficient data in 'kinetics mode' for the CXRS diagnostic. Unfortunately the signal to noise ratio was worse than expected even with a significant amount of puff being directed at the plasma.

By shot 14 we had collected the best we were going to get in 'kinetics mode' and returned to 'frame transfer' mode, which is the standard setup for the diagnostic. The Mach probes participated in the plasmas until shot #9, wherein a blown fuse (most likely) resulted in the loss of power to all the controller boards.

Several more shots were taken in frame transfer mode to really secure the gaps and the sweep. By shot #19, the DBeta CXRS diagnostic had stopped throwing errors and data was being collected at both the high-field and low-field GPI.

Shots #20-21 complete part B of the run plan, reducing the inner gap by several millimeters. Hopefully we can see a change in the position of the 'null' spot on these shots.

Shot #22 disrupted after the first sweep as we attempted to raise the current to 1MA. Thanks to Steve, the next few plasmas survived and we secured a data point for part C of the plan.

Finally we bumped up the density to 1e20 and crossed our fingers. The plasma ran well and we caught a final data point for a modified part F. The staff was gracious enough to allow us to take a final locked mode and pellet shot at the end of the run. The plasma went and the pellets were fired. An excellent day in terms of plasmas overall.

Physics Operator Summaries
Entered: Apr 10 2008 05:52:57:817PM
Author: Steve Wolfe
Physop summary for 1080410
MP#537 Momentum impulse from rapid ssep changes
SL: Marr (assisted by BLIP)
PO: wolfe

This was a moderately successful run, although I was unable to
get the fine simultaneous control of the fast SSEP sweep and gaps
that we had hoped for. The inner and outer gaps were both subject
to thrashing during the zcur sweep. I tried lots of tricks to try 
to ameliorate this, unsuccessfully. The best seemed to be to 
program a step in clearin of -2mm, as had been done on 1080314,
but this was only partially successful. I think the fundamental 
problem is the mismatch between the EF2 response time and the chopper 
and 13.8kV thyristor supplies. We did manage to tame the overshoots
and ringing on the ssep sweep somewhat by adding extra points on the
zcur sweep program, but this may have made the gaps worse.
 We ended up (after shot#19) running progamming based on 1080314009 in 
segment 2 and the more tuned sweeps developed today for the return sweep
in segment 3, which turned on at 0.9sec. Future Physops should note 
that both seg2 and 3 are needed to re-run these cases. After 
shot#21, seg2 may contain the correct programming for the second half 
of the shot, but this was not tested. 

We also discovered (the hard way) that the zcur sweep in 11msec that
works at 800kA causes disruptions at 1MA. EFC railed. That surprised 
me, but it sort of makes sense since the required voltage/current response
must go like Ip*deltaZ. Shots#24 and 25 were 1MA shots with the same 
excursion but with half the sweep rate, which did not rail. 

Shot#26 was the canonical 800kA HIREX locked mode calibration shot, plus
pellets by Brock in rampdown. 

Magnet cooling was being run at 10psi (sometimes 12psi) on the pump, 
but was nonetheless slow to get the C-right turn cold. Typical between
shot cooling times were >15minutes. However, the time for pcs changes and the
time for fiber changes by the SL and friends was often longer than this,
so in reality not much time was lost. The cyopump people (Brian, Frank,
Sue) did a good job of timing the cooldown so they were ready when it was
time to take the shot. Only one shot (#3) fizzled because of cryo burp.

The 49 peak on the RGA was pretty much gone today. Maybe all the 
disruptions yesterday cleaned up the remaining teflon. Didn't see any 
N2 leaks but these may have been masked by the cryo. At any rate, we 
did not experience the cryo saturation effect today. 

There was one computer delay when Josh had to reboot pcdaqeng1, and a
briefer hang when we lost the state information, which may have been 
a network problem. 

No time lost to cell accesses today. No power supply problems.

Scorecard:
----------
        Tests              0
        No power shots     0
        Duds               0
        Fizzles            3
        Plasmas           23 (1 disruption)
        ==========        ==
        Shots             26

Session Leader Comments
Apr 10 2008 09:12:19:070AM1080410001Kenneth MarrGood Shot. No Argon. Jogs well. Kinetics worked, but signal low.
Change ninja, add argon and Dbeta, try again.
Apr 10 2008 09:36:41:583AM1080410002Kenneth MarrGood Shot. Kinetics signals still pretty low. Turn up gain, turn up integration time.
Apr 10 2008 10:20:06:193AM1080410003Kenneth MarrFizzle
Apr 10 2008 10:30:28:677AM1080410004Kenneth Marr2ms subframe timing. Highest gain. Signal appears sufficient for analysis.
Case 1 complete with 1ms timing on the DBeta. Moving to Case 2.
Dbeta increase to 2ms timing for signal. Return to case 1 later if there's time.

Ninja puff needs increasing again. Signal isn't linear as compared to last run on 3/14. At 5ms we had ~1000 counts and now at 2ms we have ~40.


Apr 10 2008 10:57:29:380AM1080410005Kenneth MarrPlasma. Case 2 good for DBeta. Moving to Case 3.
Apr 10 2008 11:04:35:600AM1080410006Kenneth MarrPlasma. Signal still low.
Next shot: Increase to 3ms timing.
Apr 10 2008 12:13:39:303PM1080410007Kenneth MarrFound an error in binning program that changed total count number, but not the shape and noise of the signal.

Plasma. Try raising the density to increase signal.
Apr 10 2008 12:19:14:413PM1080410008Kenneth MarrPlasma. Raise density again.
Apr 10 2008 12:19:41:897PM1080410009Kenneth MarrPlasma.
Next shot: Go to case 4 for OW_PUFF study.
Apr 10 2008 02:14:54:867PM1080410010Kenneth MarrFizzle.
Apr 10 2008 02:18:22:773PM1080410011Kenneth MarrPlasma.

OW signals are moderate as are the POL.
Next shot: No CXRS changes.
Apr 10 2008 02:21:07:867PM1080410012Kenneth MarrPlasma.

OW signals are moderate as are the POL.
Next shot: Move DBeta
Apr 10 2008 01:38:11:147PM1080410013Kenneth MarrPlasma.
Next shot: Go to Frame Transfer mode. Small delay to enact the change-over.
DBeta needs more time, might miss this shot.
Apr 10 2008 02:23:21:333PM1080410014Kenneth MarrPlasma.
Frame transfer complete. Signals of a similar intensity of other 5ms run days.
DBeta still offline.
Next: No CXRS changes.

Apr 10 2008 02:23:50:257PM1080410015Kenneth MarrPlasma.
No CXRS changes.
Apr 10 2008 02:14:59:117PM1080410016Kenneth MarrFizzle.
Apr 10 2008 02:58:57:770PM1080410017Kenneth MarrPlasma.
Apr 10 2008 02:58:13:290PM1080410018Kenneth MarrPlasma. Stabilizing the gap and sweep.
CXRS data is good.
DBeta didn't take. Go to all IW fibers.
Apr 10 2008 03:49:03:083PM1080410020Kenneth MarrPlasma.
DBeta gets the IW signal.
Interesting things being seen on the poloidal passive analysis.
Apr 10 2008 03:59:03:100PM1080410021Kenneth MarrPlasma.
DBeta gets the OW signal.
Next shot: Move to 1MA. Put Lgap back to 1cm.
Apr 10 2008 04:40:47:590PM1080410022Kenneth MarrPlasma disrupts on first sweep. 1MA shot.
Next shot: Decrease the sweep.
Apr 10 2008 04:41:09:200PM1080410023Kenneth MarrPlasma 1MA shot.
DBeta gets OW data.
CXRS puff very large.
Apr 10 2008 04:42:28:067PM1080410024Kenneth MarrPlasma 1MA shot.
DBeta gets IW data.
Next shot: Raise density to 1.2e20.
DBeta stays on IW data.

Physics Operator Comments
Apr 10 2008 07:53:13:663AMSteve Wolfe
Beginning setup for Thurs 10-Apr-2008
MP#537 momentum impulse from rapid ssep changes
PO: wolfe
SL: Marr

Load from 1080314009.
This shot has +ve-going sweep in zcur at [.699,.710] and -ve sweep
at [1.00,1.02]; limits are [-.013,+.003147]. I have no idea where 
the weird upper limit comes from. Seems to have been inherited from
my setup on 1080227032, so I must have hand-drawn the upper value,
or else had a finger slip. The 16mm/11msec is consistent with what
I was doing in Feb. The longer negative sweep was done to avoid 
disruptions on 3/14. Leave these speeds, move the times per SL
request.

OK, According to Kenny's latest email, he wants the values moved to
0.74 and 1.22sec. I'm going to assume he means those are the
start times. Move these points to [.740,.751] and [1.220,1.240]
respectively. The CLEARIN trace has manual adjustments at times
[.710,.720] and [1.000,1.010] respctively. I guess the second one
should have been slower, but didn't get changed. The limits are
[-.002,-.004]. Move the times to [.740,.751] and [1.220,1.240].
Copy to wires 10 and 11.

Now check on the clearin observer times in wire 4. These are at 0.7 and
1.0 sec, and the upper null uses zxa=.39,rxa=.544. Change the times
to .74 and 1.22

Now look at the startup on this shot. It's got a 50msec pg4 puff, ok
for cryopump, maybe a tad low. RCUR=1000., Br_0=0., EF4=-1340. Leave
these for now; recent history suggests Br_0 to -.0005 may be better.
Raise PG4 from 50 to 55msec.

Back to seg2, Case A wants nl04=8e19, Ip=800kA. The load shot has 8.5e19,
so change it to 8.0. Look at the actuals on 1080314009, and it is only
at 7.8e19 with the old programming. Back to the edit wire and recall
the nl04 observer to pick up the current (??) calibration. I need to
fix custom so it fills in a date instead of "today" in the alg version
field. Maybe this will work, if not I'll change it again. He's asking
for a 10mm left gap, the old shot looks like 11mm. Run it like this and
see if he really meant to change it by 1mm. Case B calls for 7mm.
Otherwise, all the changes are to be density and current. 

Load at 10-Apr-2008 07:50:56.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done
           



Apr 10 2008 08:04:14:053AMSteve Wolfe
Ken also specified 100msec of argon. The load shot has 200msec,
so drop that

Load at 10-Apr-2008 08:04:01.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

           



Apr 10 2008 09:20:04:880AM1080410001Steve Wolfe
Shot#1: pressure 2.8e-8 at INIT before first shot (cryo on)
plasma full length. no runaways. nl04~7.5e19, we're puffing 
through pulse. One early injection .14sec
SSEp goes from -4mm to +6mm little bit of an overshoot. 
Reverse sweep goes from +8mm to -5mm, but then swings back to zero
at 1.26sec. I don't see why. Outer gap is also thrashing. 

Next: enable argon, hirex gate valve

           



Apr 10 2008 09:44:47:913AM1080410002Steve Wolfe
Shot#2: Make a two step sweep on reverse: -.005 at 1.23, then to -.013
at 1.260. Also on upward sweep, .745 to -.005, then +.003 at .755
Hold off on changes to gaps until we see how this works
           
plasma with pokes. Seem to have gotten rid of the overshoot on reverse
sweep, but it ends up oscillating about -2.4mm (on ssep).
Zmagx is going from +1.2 to -0.1cm according to fast efit,
from +1 to -0.5 on the slow. I'm not sure if this is just because
it's aliasing over the oscillations or what. 

Next: make the first leg go further than halfway


Apr 10 2008 09:58:56:803AM1080410003Steve Wolfe
Shot#3: Upsweep middle point to .747,-.001, leave endpoint at .755,.003
Reverse at 1.235,-.008; end point earlier, to 1.25 from 1.26, didn't
need to be as slow as on #2, I don't think
Argon up to 125msec

fizzle. Cryo wasn't really ready, pressure ended up at .15mTorr
Note: IGT in INIT was 6e-7 instead of on the 8 scale. Should have
had them regen a third time?

Apr 10 2008 10:18:54:663AM1080410004Steve Wolfe
Shot#4: Try again same pcs setup
pressure gets down to 7e-8 at ready; delay for I2t on EFC reading.

Upsweep middle point to .747,-.001, leave endpoint at .755,.003
Reverse at 1.235,-.008; end point earlier, to 1.25 from 1.26, didn't
need to be as slow as on #2, I don't think
Argon up to 125msec

plasma full length. Bad bounce in startup, almost lost it.

Next: Drop left gap by 1mm, try to fix overshoot
pg4 to 59sec, raise argon to 200msec


Apr 10 2008 10:41:43:570AM1080410005Steve Wolfe
Shot#5: 
Initial value from -.002 to -.005, after sweep from -.004 to -.005 (no jump)
same at the end. Smaller clearin all around. 
Rcur down by .0015 everywhere .656 to .6545
Also drop zcur by 3mm to get lower starting and endpoints on ssep by 2mm
Drag whole zcur trace down by 3mm
pg4 to 59sec, raise argon to 200msec
IGT=8e-8 at INIT
Result: plasma with pokes
Ssep is now -.6 to .5 to .3: want -.5 to +.5
reverse is +.5 to -.3:want +.5 to -.5

Need to make end zcur points different for up and down

Apr 10 2008 11:09:26:397AM1080410006Steve Wolfe
Shot#6: 
Ssep upsweep is now -.6 to .5 to .3: want -.5 to +.5
reverse is +.5 to -.3:want +.5 to -.5
First point from -.016 to -.015, end from .0002 to .0015; leave middle at
.747sec, -.003935
Reverse sweep: leave start at .0002, end from -.0159 t -.019,
leave middle at 1.235sec,-.0109
argon disabled until plenum is pumped and purged. 

Result: plasma, fast efit is coming in very slow on this one
Looks like starting and ending ssep are around -7mm, upper +5mm.
Reverse sweep looks right on, upward starts a bit low, but covers 
the range. 
Left gap is thrashing early. Delay clearin reference to .747, later one
to 1.225

Apr 10 2008 11:22:09:257AM1080410007Steve Wolfe
Shot#7: 
Left gap was thrashing early. Delay clearin reference switch to .747, 
later one to 1.225
argon should be back on at 200msec puff
pressure was 1.3e-7 at INIT, up to 2e-7 by PULSE

plasma ok, Brian says there was helium coming out, "not a lot", but
apparently enough. Gap is still thrashing, didn't seem to notice the
change. I did load it.

I think I need to put back the compensating jog in clearin that I
took out several shots ago. 

Apr 10 2008 11:35:33:270AM1080410008Steve Wolfe
Shot#8: 
Nl04 to 1.0e20
Try moving initial clearin switch to .735 before the sweep!
It's notobvious what's causing the thrash, could well be the
ef2 part of slow zcur. 

Plasma: getting a marfe when it goes to upper null,
density coming down to .86, needs more puff to keep at 1.0
Inner gap still goes down to .7cm during sweep. 
The early switch probably made it worse. Maybe if I delay until
its already solidly in upper null, like at 0.77sec

Apr 10 2008 11:54:56:083AM1080410008Steve Wolfe
Shot#9: 
Delay clearin switch to  0.77sec
Raise pg3 in seg2 to 40 and extend to 1.3sec
Add a zcur point at .77,.003
Delay for reboot of pcdaqeng1. Recool now at 23 minutes, 
IGT down to 8.7e-8 but cryopump says they will want a 3 min warning
for a regen before we shoot. 

Apr 10 2008 12:08:46:583PM1080410009Steve Wolfe
Shot#9: 
Delay clearin switch to  0.77sec
Raise pg3 in seg2 to 40 and extend to 1.3sec
Add a zcur point at .77,.003

Got the ok from jas at 26minutes, will regen cryopump first
plasma, still marfing actually worse, but got the density up,
as requested. 
Inner gap still thrashes down to .6cm during sweep. I can try putting
in a positive jog along with the sweep, or a little ahead, but
the EF2 just can't keep up with the chopper. 

Apr 10 2008 12:25:19:427PM1080410010Steve Wolfe
Shot#10: Put jog in clearin: times [.735,.740,.750,.760], 
 values=[-.005,-.001,-.001,-.005]
fizzle? pressure looks ok. maybe a bounce, but it looks like
it's moving in? Maybe a little high? 

next: Br_0 to -.0005, pg4 down to 50msec

Apr 10 2008 12:48:00:303PM1080410012Steve Wolfe
Shot#11: Br_0 to -.0005, pg4 down to 50msec
Put jog in clearin: times [.735,.740,.750,.760], 
 values=[-.005,-.001,-.001,-.005]

plasma full lengthm but marfes the whole time it's in USN
and again in rampdown. Inner gap is still doing exactly the same
thing! Doesn't even notice the little jog.

Try turning OFF the P gain on clearin during the sweep,
just leave the intergral error 


Apr 10 2008 12:59:33:040PM1080410012Steve Wolfe
Shot#12: Try turning OFF the P gain on clearin during the sweep,
just leave the intergral error 

plasma with some runaways early. No Fprobe this time, they've 
got an electronics problem. 
No change on the inner gap thrash!


Apr 10 2008 01:11:30:210PM1080410013Steve Wolfe
Shot#13: Move clearin switch to .75sec, during gap in P gain
PG4 from 50 to 55msec

plasma, still no change in the gap, maybe a little less overshoot
on the recovery. 

Next: decrease nl04 to 9e19


Apr 10 2008 01:41:12:617PM1080410014Steve Wolfe
Shot#14:decrease nl04 to 9e19
Try putting back the P gain and dropping the A integrator gate
during the transition; this may affect the zcur I gain too. 

We are having a long delay (24 minutes and counting) for a fiber
change and wavelength calibration. Now need to regen the cryopump
before we go. 

plasma, still had some marfe, at least it didn't disrupt when 
I blanked the I gate. Did it help? Doesn't look like it, looks just
the same: down to -6mm, up to 13mm,even worse!

Apr 10 2008 01:55:55:710PM1080410015Steve Wolfe
Shot#15:
Put the integrator gate back, 
Considering going back to 1080314009 when this doesn't work.

Same as earlier.
Next: import seg 2 from 1080314009 and move fast efit to .69

Apr 10 2008 02:13:02:583PM1080410016Steve Wolfe
Shot#16:
Import seg2 from 1080314009 (sweep at 0.7 and 1.0sec), fast efit bursts
at 0.69,.99sec. Supposedly this was steadier gap. It has the clearin
waveform stepping up and down during the upper null phase.
fizzle. too much puff? Back down to 50msec on pg4.

Apr 10 2008 02:36:33:897PM1080410017Steve Wolfe
Shot#17: pg4 from 55 to 50msec
Import seg2 from 1080314009 (sweep at 0.7 and 1.0sec), fast efit bursts
at 0.69,.99sec. Supposedly this was steadier gap. It has the clearin
waveform stepping up and down during the upper null phase.

While I'm waiting, take a look at shot#1, which had essentially
this programming, except at the .74 and 1.22 times. The thrash
was about half of what I'm getting lately. 

plasma full length, still marfing a little. 
some early runaways

next: go back to 15 and put back the clearin steps 


Apr 10 2008 02:49:33:693PM1080410018Steve Wolfe
Shot#18: Import seg3 from seg2 of 1080410015
change times of clearing ref to beginning of sweeps
put in -2mm step in clearin at end of first sweep and beginnging
of reverse sweep. Should look just like on 1080314009 except
transposed onto new timebase
Seg 2 off seg3 on
Efit times to .735 and 1.21

plasma: Still thrashing  on the first sweep.

Apr 10 2008 03:07:29:380PM1080410019Steve Wolfe
Shot#19: Keep the first sweep from 17 (segment2)
se second sweep from seg 3. Turn seg2 back on, seg3 time to 0.9sec
efit first burst back to .69
Now move both smaller by 3mm and rcur by 1.5mm
It's now really crazy to be running these in different segments
but do it anyway for now. There is a discontinuity in the clearin
and rcur values now, seg2 has rcur=0.6545 and seg3 has .6530
seg2 has clearin dropping from -.005 to -.007, seg3 starts -.010 and
rises to -.008. 

Plasma survived. inner gap starts at 13mm on first sweep. 
That's not what they want. Second sweep is ok.

Apr 10 2008 03:30:33:147PM1080410020Steve Wolfe
Shot#20: Change seg2 to have same values before the sweep as
seg3 does now: Rcur from .6545 to .653, clearin to -.008
At this point, I could move things all into seg2, but hold off. 
Waiting for Alex, so go ahead and start making seg2 clearin
and zcur look like seg3 after .9sec
1.22,.0002;1.235,-.0109;1.25,-.019;1.6,-.019.
Clearin change at 1.22
These changes are made in scratch but not loaded for shot#20

Plasma, marfe, gaps look ok on slow scale, have to see what 
it looks like on fast. Might need a bit smaller on inner gap at
first sweep still?


Apr 10 2008 03:52:03:617PM1080410021Steve Wolfe
Shot#21: Change clearin point at .428sec in seg2 down to -.008
Move seg2 rcur out by 1.5mm to .6545 again to reduce early sweep
outer gap. Changes noted under shot20 are loaded, but seg3 is
still on, so they aren't in effect for now. 

plasma ok, after a brief delay for computer hang. 
outer gap looks a little better. 

Next: raise Ip to 1MA

Apr 10 2008 04:16:37:303PM1080410022Steve Wolfe
Shot#22: raise Ip to 1MA, left gap back to 1cm
Increase clearin by 3mm, rcur by 1.5mm both segs 2 and 3
to go back to 10mm inner gap (I hope)

Plasma disrupts at .76sec, right after the sweep. 
Seems to overshoot in ssep, big thrash but seems to recover,
then slams up and down again. Basically railing the chopper rail to 
rail. Need to slow down or limit the magnitude of the sweep. 

Apr 10 2008 04:28:03:100PM1080410023Steve Wolfe
Shot#23: Decrease sweep in seg2 (positive sweep) to upper value
of 0 instead of +.003. Leave second sweep alone (seg3)
Decrease pg4 to 47msec
plasma all the way through. Still has an early marfe. 
Still rails efc on first sweep, but survives. SSEP is still 
ringing all the way back to zero. Need to slow it down more. 

Next: slow it down to 16mm in 20msec


Apr 10 2008 04:43:51:540PM1080410024Steve Wolfe
Shot#24: slow it down to 16mm in 20msec, 
plasma full length. EFC doesn't rail this time. 

Next: raise nl04 to 1.2e20



Apr 10 2008 05:01:49:490PM1080410025Steve Wolfe
Shot#25: raise nl04 to 1.2e20
Add a midpoint on the upsweep at .715,-.001, move endpoint from 
.72 to .725 (value .003)
Speed up current rise (1MA at .3sec instead of .35)
ssep still has an overshoot, have to live with it 

Next: locked mode shot for HIREX, pellet injection. 


Apr 10 2008 05:19:38:003PM1080410026Steve Wolfe
Shot#26: Locked mode calibration shot for hirex
 import seg3 from 1080410001
turn off seg2, leave seg3 on

plasma. Seems to be a pellet at 1.5sec, also at 1.72?
Locked mode around 0.75

END OF RUN.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:00:39:223AMPlasmaOk
209:31:37:677AMPlasmaOk
309:54:33:147AMPlasmaOk
410:12:12:350AMPlasmaOk
510:32:39:787AMPlasmaOk
610:52:25:710AMPlasmaOk
711:10:18:257AMPlasmaOk
811:28:03:303AMPlasmaOk
912:00:23:583PMPlasmaOk
1012:18:34:380PMPlasmaOk
1112:31:17:443PMPlasmaOk
1212:47:41:913PMPlasmaOk
1301:06:54:943PMPlasmaOk
1401:37:31:350PMPlasmaOk
1501:51:29:100PMPlasmaOk
1602:09:46:413PMPlasmaOk
1702:22:15:960PMPlasmaOk
1802:43:35:677PMPlasmaOk
1903:02:01:163PMPlasmaOk
2003:23:32:193PMPlasmaOk
2103:48:16:520PMPlasmaOk
2204:03:47:460PMPlasmaOk
2304:19:46:397PMPlasmaOk
2404:36:52:280PMPlasmaOk
2504:55:24:770PMPlasmaOk
2605:10:00:553PMPlasmaOk

System Availability
Apr 10 2008 09:00:30:053AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDyesFully operationalMar 28 2007 09:19PM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyesvertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm.Feb 06 2007 10:00AM (bravenec)Ron BravenecBeam Emission Spectroscopybravenec,rowan
BolometersyesDiode 2pi working fine, foil 2pi being low-pass filtered to remove noise. Outboard miidplane AXUV has a grounded channel which is disrupting the whole array OFFLINE for now. Midplane foils working fine, but need to fill tree with calibrations. 2D AXUV arrays are being digitized but need further debugging and calibration.Mar 14 2008 11:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoFirst Boronization 5/9/07 Bottle has been removed from the cellSep 14 2007 12:42PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAyesSingle channel CNPA available as of 12/1707Dec 17 2007 05:48PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesCryopump is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm.Nov 27 2007 10:21AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,rachmcd,rowan
D Alphayes\ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are availableNov 26 2007 04:23PM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayesoptics repaired, camera re-installed, and view has been re-calibratedNov 27 2007 09:54AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationno Nov 20 2007 10:47PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBno Nov 20 2007 10:47PM (granetz)Robert GranetzDiagnostic Neutral Beambeals,granetz
FRC-ECEyes16 Channels now working - low freq. side - outer RmidsFeb 19 2008 09:56AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge is operational and calibrated against G-side MKS on shot#1071127002Nov 27 2007 01:25PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
GPCyesAll 9 channels operational as of new year.Jan 03 2008 09:31AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jan 02 2008 12:22PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPInoNeither the Xpt-view nor the midplane-view camera is operational. Nov 26 2007 04:25PM (terry)Jim TerryGas Puff Imagingterry,zweben
H/DyesShould be operational for the FY08 campaignNov 27 2007 09:54AM (marmar)Earl MarmarH/D Ratiomarmar
Hirex Jryes Mar 06 2007 08:59AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SrnoBe Window has a leak and so the gate valve is closedNov 23 2007 12:50PM (ince)John RiceHigh Resolution X-Rayince,rice
HXRyesSomething might be wrong with channel 26; all others working fine.Mar 23 2007 10:43AM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesavailable (quarter-wave transformer for pre-matching)Dec 11 2007 09:01AM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesavailable (with FFT for automatical matching)Dec 11 2007 09:01AM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesnormally in [0,pi,pi,0] phase for heating. current drive phase available if requested.Dec 11 2007 09:03AM (ylin)Steve WukitchJ-port antennawukitch,ylin
Lower HybridyesBody I Fault Circuits Repaired and tested. High power tests completedDec 05 2007 06:40PM (dterry)Ron ParkerLower Hybriddterry,parker
LPIyes1/9/08Jan 09 2008 03:23PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane working fine, emissivity profiles being stored in tree, but still need to apply in-vessel calibrations to data. WB1-LY being digitized, but not processed in tree.Dec 09 2007 06:53PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonnoProblems with detector. No quantitative line brightnesses possible. Qualitative tasks like impurity identification possible.Feb 15 2008 02:07PM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesWorking, moderate speed for now.Jan 02 2008 01:19PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesE-Top, E-Bottom, F-top (cryo), G-side, and B-bottom are operational. F-top gauge has a 'sniffer tube' to measure pressures in cryopump gas box.Mar 20 2007 06:42PM (g)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoInitial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. May 30 2007 08:01PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoWe are basically awaiting the DNB & its new aperture. MSE itself is OK.Feb 21 2008 08:51AM (jinseok)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for the He3 bank. Voltage will be turned on for the global system at the first plasma attempts.Nov 26 2007 08:31AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and Hardsyescalibration unchanged from 2007 campaignDec 04 2007 08:56PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAyesAll capillaries displayed by the NINJA_CONTROL GUI have been tested. Nov 26 2007 04:26PM (terry)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesworkingFeb 29 2008 07:00PM (lianglin)Miklos PorkolabPhase Contrast Imagingedlund,lianglin,ntsujii,porkolab
Penning GaugesyesAll gauges except B_DivL are operatingNov 27 2007 01:31PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Nov 26 2007 04:27PM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Probe Array - ISDyesOperationalNov 27 2007 01:40PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperationalNov 27 2007 01:40PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
Reflectometeryes50, 60, 88 and 110 are connected (75 is being repaired). variable freq. and 140 are also connected but not functioning properlyApr 03 2008 12:20PM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational, but needs to be checked with plasma.Nov 27 2007 01:45PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesFSP is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA- and K-port WASP electrodes have been replaced/tested.Nov 27 2007 01:44PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
TCIyesCO2 Laser is on --- initial alignment completeNov 16 2007 01:23PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CorenoYAGs are offline due to technical difficulties. Apr 09 2008 08:16PM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma
TS - EdgenoSystem is working with 3 out of 4 spectral channels and should be believable for Te>50eV, ne>3e19. Density is calibrated from both Raman scattering in D2 (3/2/08) and from edge ECE cutoffs in high-density H-modes (1080228014).Apr 09 2008 08:15PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyessystem operational, but channels have been dying...stay tuned.Mar 14 2008 11:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke


Apr 10 2008 12:00:16:630PM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDyesFully operationalMar 28 2007 09:19PM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyesvertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm.Feb 06 2007 10:00AM (bravenec)Ron BravenecBeam Emission Spectroscopybravenec,rowan
BolometersyesDiode 2pi working fine, foil 2pi being low-pass filtered to remove noise. Outboard miidplane AXUV has a grounded channel which is disrupting the whole array OFFLINE for now. Midplane foils working fine, but need to fill tree with calibrations. 2D AXUV arrays are being digitized but need further debugging and calibration.Mar 14 2008 11:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoFirst Boronization 5/9/07 Bottle has been removed from the cellSep 14 2007 12:42PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAyesSingle channel CNPA available as of 12/1707Dec 17 2007 05:48PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesCryopump is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm.Nov 27 2007 10:21AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,rachmcd,rowan
D Alphayes\ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are availableNov 26 2007 04:23PM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayesoptics repaired, camera re-installed, and view has been re-calibratedNov 27 2007 09:54AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationno Nov 20 2007 10:47PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBno Nov 20 2007 10:47PM (granetz)Robert GranetzDiagnostic Neutral Beambeals,granetz
FRC-ECEyes16 Channels now working - low freq. side - outer RmidsFeb 19 2008 09:56AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge is operational and calibrated against G-side MKS on shot#1071127002Nov 27 2007 01:25PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
GPCyesAll 9 channels operational as of new year.Jan 03 2008 09:31AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jan 02 2008 12:22PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPInoNeither the Xpt-view nor the midplane-view camera is operational. Nov 26 2007 04:25PM (terry)Jim TerryGas Puff Imagingterry,zweben
H/DyesShould be operational for the FY08 campaignNov 27 2007 09:54AM (marmar)Earl MarmarH/D Ratiomarmar
Hirex Jryes Mar 06 2007 08:59AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SrnoBe Window has a leak and so the gate valve is closedNov 23 2007 12:50PM (ince)John RiceHigh Resolution X-Rayince,rice
HXRyesSomething might be wrong with channel 26; all others working fine.Mar 23 2007 10:43AM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesavailable (quarter-wave transformer for pre-matching)Dec 11 2007 09:01AM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesavailable (with FFT for automatical matching)Dec 11 2007 09:01AM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesnormally in [0,pi,pi,0] phase for heating. current drive phase available if requested.Dec 11 2007 09:03AM (ylin)Steve WukitchJ-port antennawukitch,ylin
Lower HybridyesBody I Fault Circuits Repaired and tested. High power tests completedDec 05 2007 06:40PM (dterry)Ron ParkerLower Hybriddterry,parker
LPIyes1/9/08Jan 09 2008 03:23PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane working fine, emissivity profiles being stored in tree, but still need to apply in-vessel calibrations to data. WB1-LY being digitized, but not processed in tree.Dec 09 2007 06:53PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonnoProblems with detector. No quantitative line brightnesses possible. Qualitative tasks like impurity identification possible.Feb 15 2008 02:07PM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesWorking, moderate speed for now.Jan 02 2008 01:19PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesE-Top, E-Bottom, F-top (cryo), G-side, and B-bottom are operational. F-top gauge has a 'sniffer tube' to measure pressures in cryopump gas box.Mar 20 2007 06:42PM (g)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoInitial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. May 30 2007 08:01PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoWe are basically awaiting the DNB & its new aperture. MSE itself is OK.Feb 21 2008 08:51AM (jinseok)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for the He3 bank. Voltage will be turned on for the global system at the first plasma attempts.Nov 26 2007 08:31AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and Hardsyescalibration unchanged from 2007 campaignDec 04 2007 08:56PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAyesAll capillaries displayed by the NINJA_CONTROL GUI have been tested. Nov 26 2007 04:26PM (terry)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesworkingFeb 29 2008 07:00PM (lianglin)Miklos PorkolabPhase Contrast Imagingedlund,lianglin,ntsujii,porkolab
Penning GaugesyesAll gauges except B_DivL are operatingNov 27 2007 01:31PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Nov 26 2007 04:27PM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Probe Array - ISDyesOperationalNov 27 2007 01:40PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperationalNov 27 2007 01:40PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometernoSystem has been disconnected on 1080410000Apr 10 2008 11:57AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational, but needs to be checked with plasma.Nov 27 2007 01:45PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesFSP is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA- and K-port WASP electrodes have been replaced/tested.Nov 27 2007 01:44PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
TCIyesCO2 Laser is on --- initial alignment completeNov 16 2007 01:23PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CorenoYAGs are offline due to technical difficulties. Apr 09 2008 08:16PM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma
TS - EdgenoSystem is working with 3 out of 4 spectral channels and should be believable for Te>50eV, ne>3e19. Density is calibrated from both Raman scattering in D2 (3/2/08) and from edge ECE cutoffs in high-density H-modes (1080228014).Apr 09 2008 08:15PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyessystem operational, but channels have been dying...stay tuned.Mar 14 2008 11:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke