Alcator C-Mod Run 1080502 Information

Back to runs

Miniproposals
Miniproposal:535a
Date Filed: 3/5/2008
Title:Rotation inversion vs density and current, in limited and diverted L-mode plasmas
First Author:Basil Duval
Session Leader:Basil Duval (shots 2-17)
Session Leader:Alex Ince-Cushman (shots 21-24)
Miniproposal:550
Date Filed: 4/15/2008
Title:Locked Mode Rotation Studies
First Author:Alex Ince-Cushman
Session Leader:Alex Ince-Cushman (shots 18-24)

Operators
Session leader(s):Basil Duval,Alex Ince-Cushman,Alex Ince-Cushman
Physics operator(s):Jim Irby
Engineering operator(s):Bill Parkin,Bill Cochran

Engineering Operator Run Comment
am: MP535a Rotation inversion in improved L-mode pm: MP550 Momentum tran

Session Leader Plans
Entered: May 1 2008 01:04:05:947PM
Author: Yijun Lin
SL-plan: 1080502, 17:00 pm - 18:00 pm
MP 378, MC flow study with J-antenna at 50 MHz.

shots
1. Reload shot 1080422026, USN, 800 kA shot. 5.1 Tesla. No He3-puff. Need Argon puff. Run J 2 MW flat, then D+E steps to 2.5 MW. Check rotation and impurity temperature.

2. Run J, 4 steps to 3 MW, 50 ms He3 puff starting at 0.2 sec, counter-cd phase.

3. Run J, 4 steps to 3 MW, 150 ms He3 puff. counter-cd phase.

4. To be determined. (May repeat 3, with co-cd phase, or with 200 ms He3 puff).

5. To be determined.

Physics Operators Plans
Entered: May 2 2008 08:34:48:600AM
Author: Jim Irby
-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 18:00 (one extra hour)

Power systems as on:

am: MP535a Rotation inversion in improved L-mode
load shot 1080215001 --- locked mode fiducial shot

pm: MP550 Momentum transport w/A-coil locking
load shots 1080215001 and 1080130025

17:00-18:00: Y. Lin
load shot 1080422026
He3 injection from B-side upper

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Special gas: Helium-3, B-upper, 15 PSI --- at end of run

Enable gatevalves and shutters: ECE, VUV, DNB, Z-bolo

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes
ICRF(yes/no): yes
LH(yes/no): no
DNB(yes/no): yes
Cryopump (yes/no): no

Overnight vessel temperature: 60/60/60

------------------------------
ECDC Parameters
------------------------------
gas and pressure: D2 at 2e-4 Torr
sweep: 44/45/103 cm
scan: 20/120 s

Session Leader Summaries
Entered: May 2 2008 05:34:02:230PM
Author: John Rice
Session Leader Run Summary for 1080502 MP535a Rotation Inversion vs Density and Current, in Limited and Diverted L-mode Plasmas

The first 2 shots were devoted to obtaining locked modes, for wavelength calibrations for HIREX-Sr. Shots
4-9 were spent performing a density scan in LSN discharges with current around 0.65 MA, magnetic field
of 3.0 T and q95 of 3. For a range of average densities between .35 and 0.7 10^20/m^3, and no rotation
inversion was found. For shots 10-16, limited discharges were run, and good rotation inversions were found
on 14 and 15, where the average density was around .7. For higher and lower densities, no inversion was seen.
For shots 14 and 15, the rotation inversion occured inside of R=0.82 m only, and seem qualitatively
similar to the TCV results. After 12:30, there were no further shots, due to a variety of problems.

Physics Operator Summaries
Entered: May 2 2008 06:40:38:093PM
Author: Jim Irby
Until we had a problem with the OH2U commutation system and then the
data system we were doing extremely well today. We began with
1080215001, the locked mode fiducial for calibration of the rotation
diagnostics. Then we started mp53a to study rotation reversal in l-mode
plasmas by loading 1080430002, adjusted for 3 rather than 3.3T. After
several shots with variations of Ip and density, we went limited on shot
1080502010, to stay out of h-mode. SL generally got what he wanted
except for a density ramp shot that fizzled because of the OH2U
commutation problem. Unfortunately we were unable to get any data for
Alex and Yijun today.

After about 13:00 things went south with data and power system
problem. Even the PEI air switch did us in on shot 25, after which we
gave up.


-----------------------------------------------
problems:

Oh2u did not commutate on shot 017. PFN current only 20 kA. Blown
fuses were found and replaced.

Oh2s misbehaved on shot 023 producing a fizzle. Currents go awry from
-1.1 s on both oh2u and oh2l.

On shot 024 we had a forced invert because of a type II fault generated
by an I^2t from ef1u. Still had same oh problem we had on 023.

On shot 025 PEI air would not open.

shot 19 does not exist

------------------------------------------------

Score:

power system troubles 017,023,024,25
no power 018,020,21,22
plasma 01,02,03,04,05,06,07,08,09,10
11,12,13,14,15,16


Session Leader Comments
May 2 2008 12:45:29:793PM1080502004Basil DuvalPre: Locked mode reference for Vphi=0
Post: OK
May 2 2008 12:47:35:937PM1080502005Basil DuvalPre: Lower Ne-
Post: OK, qe ~3.2 small H-mode later (apparently normal at lower Bphi and Ip)
Note: Since breakdown is at 5T, it takes until ~0.55s until the target 3T field is attained- This is the fastest that the power supplies allow- Could a breakdown at lower Bphi be designed ?
May 2 2008 12:48:49:623PM1080502006Basil DuvalPre: Lower Ne- 0.4 -> 0.3 (this is a diverted lower null config)
Post: OK- Vphi still positive- little change here-
May 2 2008 12:49:50:483PM1080502007Basil DuvalPre: Lower Ne- 0.3 -> 0.2
Post: OK- Significant Hard X- This is as low as we can go in this config- time to start to play with Ip-
May 2 2008 12:51:48:250PM1080502008Basil DuvalPre: Ne back to 0.3 (same as for 006) Ip raised from 600-650kA (lower q)
Post: OK- Disrupt at 1.5s- Odd ? qe reconstructed as 2.9 -> 3.3 at disruption although the Ip does not seem to change much- Are we looking at minor shape changes or is there a current profile change or ???
May 2 2008 12:54:02:677PM1080502009Basil DuvalPre: Ne ramp to higher Ne- Try to cover the whole Ne range in one discharge
Post: OK- Disrupt again, but nothing to get excited about with Vphi- Looks like we're not in a good range of parameters for this diverted configuration, so it is time to look at a limited equivalent to see if there is any change in rotation direction (as would be expected from the TCV observations)
May 2 2008 12:26:46:547PM1080502010Basil DuvalPre: Keep shape and Ip- go for LIMITED config
Post: Worryingly little change- density kind of high-> look towards lower Ne ?
May 2 2008 12:25:28:607PM1080502011Basil DuvalPre: Repeat: Looking for lower Ne (0.8 and 0.4 to cover same range as for diverted config)
Post: Still rather high... (Vtor boring and still zero or co-current)
May 2 2008 12:24:13:683PM1080502012Basil DuvalPre: Go for 0.8 (John units this time)
Post: Still rather high... (Vtor still boringly similar...)
May 2 2008 12:22:26:230PM1080502013Basil DuvalPre: Go for 0.8 (John units) again
Post: Still only got down to ~1.1- Perhaps we could reduce the gas feed in the early discharge formation (during the Bphi ramp)
May 2 2008 12:17:18:320PM1080502014Basil DuvalPre: Lower density (aiming for average 0.8e20)
Post: Got a "step" in the toroidal velocity response at ~0.8sec i.e. after the Bphi was established- This could be what we are looking for if there is Hysterisis in that the rotation did not decrease again when the density went up
May 2 2008 12:20:22:010PM1080502015Basil DuvalPre: Lower density further
Post: Looking INTERESTING ! density slightly lower gave a "transition" a little later in discharge- Still not occurring in stationary conditions- Aim to reduce density further and when stabilised, attempt a programmed density ramp to manually take the plasma across the threshold that seems to be ~0.8 on C-MOD for this shape (Must not forget that this is LIMITED)
May 2 2008 12:35:49:537PM1080502016Basil DuvalPre: Go for still lower Ne, rest of config similar
Post: OK ! now the whole duration is at the higher rotation speed (Ne is lower)
Assuming this means that we are now "below" threshold, then we may now program a density ramp from ~1s until the end of the discharge to get a transition.
May 2 2008 01:11:37:143PM1080502017Basil DuvalPre: Density ramp from 1s from ~0.75 to 1.0- Look for a change during this period
(Note: edge seems little affected (like TCV) and profile is changing inside q ~1.5 which is again in agreement with TCV- Interesting, however, if +ve velocity is co-current, we are obtaining a transition Co to Counter with increasing density- This is the opposite to the TCV observation which has this behaviour for DIVERTED discharges- How limited are these C-mod discharges ? (UK spelling on purpose !)
Post: BLIP- try again...

PostPost: Fuse replacements etc. require over an hour- End of this part of the session-
Get the ramp performed during Alex's part of the programme-

Suggest:

1) the density ramp that we had hoped for this discharge
2) Repeat the SAME density ramp with 15-20% higher current (800kA)

If we see anything, we will immediately have to look into the following

1) Complete profiles reconstructed from all diagnostics
2) Behaviour of the edge D-rotation (HFS gas jet)
3) Mode changes near to or across the Vphi change (resolved by the magnetic structure as a radius (i.e. inside and outside the Vphi affected region))
4) Double the Argon input for these low densities to exclude any parametric effect-
5) take Bphi up in a couple of steps to see if this can all be performed at full field (TCV results have only good things to say about increasing the toroidal field but this has really not been extensively investigated)

If you have contingency time in C-Mod's planning, can we request more shots ?

A big thanks to everyone for the help !

_basil

Physics Operator Comments
May 2 2008 09:43:17:607AM1080502001Jim Irbyload from 1080215001 --- locked mode standard shot
rcur=1000, prefill -0.525 to 0.500 s, 200 ms of argon, 800 kA, 5.45 T
loaded

RGA filament failed early this morning. Now back to rga head on ps1. GV1 closed as it cleans up. BP 4.8e-7 Torr in torus.

08:00 --- having issues with pcdaqcamac. Reboot does not seem to help. Josh will be in by 08:40

08:02 --- we can ping pcdaqcamac

08:10 --- test shots run okay now

08:30 --- no cycle test okay
May 2 2008 09:12:47:863AM1080502002Jim Irbyplasma into rampdown but I forgot to enable argon
May 2 2008 09:31:42:630AM1080502003Jim Irbyargon enabled --- 200 ms starting at 0.3 s
Hirex gatevalve enabled

cell entry: reboot TS computer, start up a transmitter or two
cell access done by recool+10:04

plasma --- some runaways --- got locked mode
density risetime slower than on shot 02
May 2 2008 09:59:21:713AM1080502004Jim Irbyload from 1080430002 --- rcur 1000, bt 3.3 T
seg01 and seg03 active
loaded
TF to 3.0 T --- 82.27kA
loaded

checked prefill after I had pushed the button ---- 26 ms

plasma into rampdown ----


May 2 2008 10:03:58:640AM1080502005Jim IrbyIp from 600 to 650 kA
TF current from 82.27kA to 78.5kA
loaded

plasma into rampdown --- Bt 3.008T --- ohmic h-mode around 1.2 s
some hard early --- current rolled over but recovered at 0.12 s




May 2 2008 10:19:59:307AM1080502006Jim Irbynl_04 request from 0.4e20 to 0.3e20/m^2
loaded

plasma into rampdown --- density about right
May 2 2008 10:28:41:173AM1080502007Jim Irbynl_04 request to 0.2e20/m^2
loaded

plasma into rampdown --- lots of snow


May 2 2008 10:40:06:293AM1080502008Jim IrbyIp to 700 kA
nl_04 request back to 0.3e20/m^2
loaded

plasma to 1.56 s --- pushing q


May 2 2008 10:59:45:463AM1080502009Jim Irbyprefill from 26 to 24 ms --- disruption black magic
nl_04 request now ramping from 0.5 to 1.8 s from 0.3e19/m^2 to 0.8e19/m^2

plasma for 1.44 s --- h-mode and then..

May 2 2008 11:06:12:763AM1080502010Jim Irbygo limited --- CLEARIN from -0.0005 to -0.0115 m --- inner gap was 0.011 m last shot
Ip from 700 to 650 kA
loaded

plasma for 1.8 s --- inner gap still non-zero


May 2 2008 11:19:53:383AM1080502011Jim Irbyramped CLEARIN more negative to keep it on the wall
nl_04 ramp now reversed: 0.5 to 1.8 s, 0.8e19/m^2 to 0.3e19/m^2
loaded

plasma for 1.36 s --- may have ramped CLEARIN too hard --- stayed limited though
density overshot and then didn't rampdown
May 2 2008 11:33:50:457AM1080502012Jim Irbynl_04 now flat at 0.8e20/m^2
CLEARIN ramped to -0.018 at 1.6 s instead of -0.020 m
loaded

plasma into rampdown --- inner gap okay


May 2 2008 11:48:35:377AM1080502013Jim Irbynl_04 request from 0.8e19/m^2 to 0.6e19/m^2
CLEARIN at 1.6s from -0.018 to -0.0185 m
loaded

argon from 0.30 to 0.45 s (150 ms from 100 ms)

plasma for 1.717 s --- clearin better


May 2 2008 11:58:54:603AM1080502014Jim Irbynl_04 request to 0.5e19/m^2 --- reduced ramp up also
CLEARIN back to -0.02 m at 1.6 s
loaded

plasma into rampdown --- density okay
CLEARIN good
May 2 2008 12:16:59:803PM1080502015Jim Irbynl_04 request to 3e19/m^2
loaded

plasma into rampdown --- density lower, but not 3e19/m^2


May 2 2008 12:27:27:390PM1080502016Jim Irbynl_04 request to 2e19/m^2 --- also ramped down before 0.5 s to reduce early gas puff.
gas is off by 0.5 s, so what we do early will matter --- walls should unload a little too as we go.
loaded

plasma into rampdown --- nl 0.44e19/m^2





May 2 2008 01:06:58:920PM1080502017Jim Irbynl_04 ramping from 1.0 to 1.5 s from 2e19/m^2 to 6e19/m^2
loaded

fizzle even w/o oh2u commutation

oh2u PFN current only about 20kA

13:05 **** down about 1 hour to investigate blown fuses *****
May 2 2008 02:47:46:837PM1080502018Jim Irby14:25 This shot will be a PLC controlled test of the commutation banks

data system issues ---- no Rogowski data

data back

commutation looks good

May 2 2008 02:56:54:487PM1080502019Jim IrbyTry for plasma --- try to get shot for Basil with the density ramp

no power shot instead ---- data system problems again
Josh needs access to power room
May 2 2008 04:10:43:137PM1080502020Jim IrbyOne more no power test

looks okay --- got gas


May 2 2008 04:24:38:757PM1080502021Jim IrbyAnother no power shot --- oh2 com didn't charge ---
power room entry --- switches had been left in off position following fuse check

May 2 2008 04:34:04:870PM1080502022Jim Irbyno power shot

May 2 2008 05:00:31:440PM1080502023Jim Irbytry for plasma

fizzle --- oh2s misbehave from startup at -1.1 s

May 2 2008 05:14:14:903PM1080502024Jim Irbytry again

all supplies invert at -0.07 s???????????

type II fault ef1u I^2t
May 2 2008 06:34:55:357PM1080502025Jim IrbyBr0 gain from -0.3 to 0.0 s changed from 5 to 10: drive supplies a little harder during time they have been drifting off

no power shot -------- PEI air switch problem

*******************************************
*******************stop********************
***********work to do next week************
*******************************************


Engineering Operator Comments
ShotTimeTypeStatusComment
108:22:50:280AMTestOkcycle test
209:04:19:733AMPlasmaOk
309:24:04:343AMPlasmaOk
409:42:29:683AMPlasmaOk
509:57:13:163AMPlasmaOk
610:09:46:080AMPlasmaOk
710:22:26:107AMPlasmaOk
810:34:56:960AMPlasmaOk
910:48:00:923AMPlasmaOk
1011:01:35:777AMPlasmaOk
1111:14:18:100AMPlasmaOk
1211:27:15:967AMPlasmaOk
1311:39:55:557AMPlasmaOk
1411:53:03:987AMPlasmaOk
1512:08:57:267PMPlasmaOk
1612:24:16:510PMPlasmaOk
1712:38:24:837PMPlasmaBadOH2U did not commutate
1802:30:58:083PMTestOkOH1, OH2U and OH2L commutation test
2003:13:54:763PMPlasmaBadNo Power Shot
2104:16:31:390PMPlasmaBadOH2 did not charge, needs to be reset
2204:32:00:510PMPlasmaBadOH2 failed to charge. Spellman power supplies were not turned on.
2304:45:40:943PMPlasmaBadThe OH2s did not follow their commands
2405:05:15:803PMPlasmaBadOH2s did not follow command
2506:28:36:663PMPlasmaBadNo power shot

System Availability
May 2 2008 08:22:43:543AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDyesFully operationalMar 28 2007 09:19PM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyesvertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm.Feb 06 2007 10:00AM (bravenec)Ron BravenecBeam Emission Spectroscopybravenec,rowan
BolometersyesDiode 2pi working fine, foil 2pi being low-pass filtered to remove noise. Outboard miidplane AXUV has a grounded channel which is disrupting the whole array OFFLINE for now. Midplane foils working fine, but need to fill tree with calibrations. 2D AXUV arrays are being digitized but need further debugging and calibration.Mar 14 2008 11:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationyesSystem OperationalApr 29 2008 03:29PM (irby)Jim IrbyBoronizationdekow,irby
CNPAyesSingle channel CNPA available as of 12/1707Dec 17 2007 05:48PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesCryopump is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm.Nov 27 2007 10:21AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,rachmcd,rowan
D Alphayes\ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are availableNov 26 2007 04:23PM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayesoptics repaired, camera re-installed, and view has been re-calibratedNov 27 2007 09:54AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationno Nov 20 2007 10:47PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBno Nov 20 2007 10:47PM (granetz)Robert GranetzDiagnostic Neutral Beambeals,granetz
FRC-ECEyes16 Channels now working - low freq. side - outer RmidsFeb 19 2008 09:56AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge is operational and calibrated against G-side MKS on shot#1071127002Nov 27 2007 01:25PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
GPCyesAll 9 channels operational as of new year.Jan 03 2008 09:31AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jan 02 2008 12:22PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPInoNeither the Xpt-view nor the midplane-view camera is operational. Nov 26 2007 04:25PM (terry)Jim TerryGas Puff Imagingterry,zweben
H/DyesShould be operational for the FY08 campaignNov 27 2007 09:54AM (marmar)Earl MarmarH/D Ratiomarmar
Hirex Jryes Mar 06 2007 08:59AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SrnoBe Window has a leak and so the gate valve is closedNov 23 2007 12:50PM (ince)John RiceHigh Resolution X-Rayince,rice
HXRyesSomething might be wrong with channel 26; all others working fine.Mar 23 2007 10:43AM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesavailable (quarter-wave transformer for pre-matching)Dec 11 2007 09:01AM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesavailable (with FFT for automatical matching)Dec 11 2007 09:01AM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesnormally in [0,pi,pi,0] phase for heating. current drive phase available if requested.Dec 11 2007 09:03AM (ylin)Steve WukitchJ-port antennawukitch,ylin
Lower HybridyesBody I Fault Circuits Repaired and tested. High power tests completedDec 05 2007 06:40PM (dterry)Ron ParkerLower Hybriddterry,parker
LPIyes1/9/08Jan 09 2008 03:23PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane working fine, emissivity profiles being stored in tree, but still need to apply in-vessel calibrations to data. WB1-LY being digitized, but not processed in tree.Dec 09 2007 06:53PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonnoProblems with detector. No quantitative line brightnesses possible. Qualitative tasks like impurity identification possible.Feb 15 2008 02:07PM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperationalApr 29 2008 02:30PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesE-Top, E-Bottom, F-top (cryo), G-side, and B-bottom are operational. F-top gauge has a 'sniffer tube' to measure pressures in cryopump gas box.Mar 20 2007 06:42PM (g)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoInitial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. May 30 2007 08:01PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoWe are basically awaiting the DNB & its new aperture. MSE itself is OK.Feb 21 2008 08:51AM (jinseok)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for the He3 bank. Voltage will be turned on for the global system at the first plasma attempts.Nov 26 2007 08:31AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and Hardsyescalibration unchanged from 2007 campaignDec 04 2007 08:56PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAyesAll capillaries displayed by the NINJA_CONTROL GUI have been tested. Nov 26 2007 04:26PM (terry)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesworkingFeb 29 2008 07:00PM (lianglin)Miklos PorkolabPhase Contrast Imagingedlund,lianglin,ntsujii,porkolab
Penning GaugesyesAll gauges except B_DivL are operatingNov 27 2007 01:31PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Nov 26 2007 04:27PM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Probe Array - ISDyesOperationalNov 27 2007 01:40PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperationalNov 27 2007 01:40PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperationalNov 27 2007 01:41PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesSystem is fully connected except for the 75GHz channel. System was connected on 1080422.Apr 22 2008 08:26AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational, but needs to be checked with plasma.Nov 27 2007 01:45PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesFSP is operationalDec 11 2007 10:13AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA- and K-port WASP electrodes have been replaced/tested.Nov 27 2007 01:44PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
TCIyesOperational Apr 29 2008 03:33PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CoreyesOne laser operational, 12 spatial channelsApr 11 2008 10:36AM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma
TS - EdgeyesSystem is working with 3 out of 4 spectral channels and should be believable for Te>50eV, ne>3e19. Density is calibrated from both Raman scattering in D2 (3/2/08) and from edge ECE cutoffs in high-density H-modes (1080228014).Apr 11 2008 10:36AM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyessystem operational, but channels have been dying...stay tuned.Mar 14 2008 11:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke