| Miniproposals |
| Operators | |
| Session leader(s): | |
| Physics operator(s): | Steve Wolfe,Steve Wolfe,Earl Marmar |
| Engineering operator(s): | Bill Cochran |
| Engineering Operator Run Comment |
| Power System Test |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Physics Operator Summaries |
| Entered: Jun 19 2009 04:16:31:123PM |
| Author: Earl Marmar |
| power tests went quite well today, with all but the TF tests successfully completed.
The TF tests were not done, because the TF scanner is not operational. |
| Session Leader Comments |
| Physics Operator Comments | |||
| Jun 19 2009 08:50:40:517AM | 1090619002 | Steve Wolfe | Shot#3: THe first shot will be an efc test. Bill wants to run it like 1060207008, which had the software fizzle detector disabled. I will load this one and let them run it. Since it is so old I need to recalculate all the predictors, in case some of the diagnostics don't exist anymore. Also, the po signin gave me trouble signing in. |
| Jun 19 2009 09:00:00:647AM | 1090619002 | Steve Wolfe | Shot#3: Recalculate all the magnetic predictors in segs 1 and 2. Zero segs 3 and 4 (won't be using those, but I don't want to leave them around. When we're through with the efc tests, I want to bring back the model from 1090619001 (as at the beginning, to be sure we have a modern setup.) Load into model about to ask alcdata-models to copy /home/wolfe/pcs_scratch/pcs_model to /cmod/trees/models/pcs/pcs_model about to ask alcdata-models to copy /home/wolfe/pcs_scratch/dpcs_model to /cmod/trees/models/dpcs/dpcs_model Load at 19-Jun-2009 08:59:34.00 Open tree /home/wolfe/pcs_scratch -1 Open tree done Should be ready to go, I hope. |
| Jun 19 2009 09:26:42:470AM | 1090619003 | Steve Wolfe | Shot#3: EFC test, with dpcs_fizzle procedure turned off, based on 1060207008 (but with different PLC voltage limits) Earl came in and tried to bring up Pcs on cmodwsd50 and got errors in evaluating mds expressions, wrong ELF type, looks like it can't find the 64bit mdslibraries or an ldconf.so problem. Also complained couldn't find the model files. I exited pcs and got back in, it found the files fine. Should be ok for this shot, but I'll reload them again just in case. about to ask alcdata-models to copy /home/wolfe/pcs_scratch/pcs_model to /cmod/trees/models/pcs/pcs_model about to ask alcdata-models to copy /home/wolfe/pcs_scratch/dpcs_model to /cmod/trees/models/dpcs/dpcs_model Load at 19-Jun-2009 09:26:05.00 Open tree /home/wolfe/pcs_scratch -1 Open tree done |
| Jun 19 2009 09:34:44:097AM | 1090619003 | Steve Wolfe | Shot#3: EFC test, with dpcs_fizzle procedure turned off, based on 1060207008 (but with different PLC voltage limits) Shot ran, efc pulse looks ok to me; the issue in 2006 was that they wanted to see a soft turn off, and the f.d. was giving something else. I may actually have fixed that at some point, but this should look just like the 1060207 pulse. |
| Jun 19 2009 09:46:52:227AM | 1090619004 | Steve Wolfe | Shot#4: EFC test, with dpcs_fizzle procedure turned off, based on 1060207008 (but with different PLC voltage limits) Same shot with higher voltage limit on PLC. Looks ok to me. |
| Jun 19 2009 09:57:34:057AM | 1090619005 | Steve Wolfe | Shot#5: EFC test, with dpcs_fizzle procedure turned off, based on 1060207008 (but with different PLC voltage limits) Same shot with higher voltage limit on PLC. looks ok Bob is reporting a number of bad flux loop signals including f12. |
| Jun 19 2009 10:15:37:643AM | 1090619006 | Steve Wolfe | Shot#6: EF2 test under plc control. The most recent set of power system tests were 1071120, and this was before the declaration that the flux loops had been fixed, so predictor recalculations will be required in any case. The acoil test that Gary and Bill want to use is 1070801004. This one has seg 1 only on and a programmed acoil current with a two level waveform that only goes over 1000 amps for a brief time. I don't think this will be satisfactory, but we can try it. At least it still has the dpcs_fizzle on! I will recalc the seg 1 predictors just in case, and zero the segs 2-4. |
| Jun 19 2009 10:20:45:520AM | 1090619007 | Steve Wolfe | Shot#7: EF2L test under plc control. Induced current in ef3 and the ef4's. For the next shot, I have loaded acoil waveform based on 1070801004 in seg1, with all the magnetics loops reconnected. I expect the acoil will only give about 400A, but maybe ok. I have zeroed all the wires in segs2-4. Only seg1 is used on this shot. I have also removed the dpcs_xjump and dpcs_gas_jet procedures, left dpcs_ftae2 installed but off. Dpcs_fizzle and baseline_sub are active. |
| Jun 19 2009 10:22:25:927AM | 1090619007 | Steve Wolfe | Shot#7: EF2L test under plc control. Induced current in ef3 and the ef4's. For the next shot, I have loaded acoil waveform based on 1070801004 in seg1, with all the magnetics loops reconnected. I expect the acoil will only give about 400A, but maybe ok. I have zeroed all the wires in segs2-4. Only seg1 is used on this shot. I have also removed the dpcs_xjump and dpcs_gas_jet procedures, left dpcs_ftae2 installed but off. Dpcs_fizzle and baseline_sub are active. Next shot will be the first acoil test, and will use this program. Load at 19-Jun-2009 10:22:07.00 Open tree /home/wolfe/pcs_scratch -1 Open tree done |
| Jun 19 2009 10:35:24:167AM | 1090619008 | Steve Wolfe | Shot#8: Acoil test looks ok, 600A or so. I'll exit and Earl will take over. |
| Jun 19 2009 10:42:13:217AM | 1090619009 | Earl Marmar | Signed in as physop
alternator ramp test, dpcs not required |
| Jun 19 2009 11:08:32:710AM | 1090619010 | Earl Marmar | load segment 1 from 1060207013
call all magnetics (RCUR, ZCUR, ZCUR, BR_0) EF3 test |
| Jun 19 2009 11:17:15:933AM | 1090619011 | Earl Marmar | load segment 1 from 1060207014
call all magnetics (RCUR, ZCUR, ZCUR, BR_0) EF4 test |
| Jun 19 2009 11:52:56:790AM | 1090619012 | Earl Marmar | no dpcs changes
EF4 test |
| Jun 19 2009 12:50:47:650PM | 1090619013 | Earl Marmar | no dpcs changes
EF1L test |
| Jun 19 2009 12:51:00:837PM | 1090619014 | Earl Marmar | no dpcs changes
EF1L test |
| Jun 19 2009 12:54:39:880PM | 1090619015 | Earl Marmar | no dpcs changes
OH1 test |
| Jun 19 2009 01:02:46:330PM | 1090619016 | Earl Marmar | no dpcs changes
OH1 test |
| Jun 19 2009 01:08:05:677PM | 1090619017 | Earl Marmar | no dpcs changes
OH2U test |
| Jun 19 2009 01:19:35:507PM | 1090619018 | Earl Marmar | no dpcs changes
OH2U test |
| Jun 19 2009 01:21:11:197PM | 1090619019 | Earl Marmar | no dpcs changes
OH2L test |
| Jun 19 2009 01:30:32:090PM | 1090619020 | Earl Marmar | no dpcs changes
OH2L test |
| Jun 19 2009 01:35:03:280PM | 1090619021 | Earl Marmar | no dpcs changes
EF1U test |
| Jun 19 2009 02:09:51:840PM | 1090619023 | Earl Marmar | import segment 1 from 1071120013
call all magnetics EF4 test under DPCS control, but no power |
| Jun 19 2009 02:25:31:410PM | 1090619024 | Earl Marmar | no dpcs changes
EF4 test under DPCS control, with power |
| Jun 19 2009 02:26:37:957PM | 1090619025 | Earl Marmar | no dpcs changes
OH commutation test (PLC control) |
| Jun 19 2009 03:23:29:650PM | 1090619027 | Earl Marmar | add gas programming for prefill and fueling (PG4 and PG3)
EF1U&L commutation test pressure rose to the 4 scale |
| Jun 19 2009 03:23:11:070PM | 1090619028 | Earl Marmar | PG4 disabled at the PLC
PG3 disabled at the PLC no pressure rise EF1U&L commutation test |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 06:45:36:203AM | Test | Ok | Datasystem Checked Out Okay |
| 2 | 08:17:51:550AM | Test | Ok | shot cycle test |
| 3 | 09:29:00:563AM | Test | Ok | EFC Test (400V) |
| 4 | 09:41:45:583AM | Test | Ok | EFC Test (600V) |
| 5 | 09:54:03:603AM | Test | Ok | EFC Test |
| 6 | 10:03:54:530AM | Test | Ok | EF2U PLC Test |
| 7 | 10:15:42:690AM | Test | Ok | EF2L PLC Test |
| 8 | 10:31:21:227AM | Test | Ok | A-Coil Test |
| 9 | 10:44:17:153AM | Test | Ok | Alternator Ramp Test |
| 10 | 11:08:36:413AM | Test | Ok | EF3 PLC Test |
| 11 | 11:42:34:693AM | Test | Ok | EF4 Forward PLC Test |
| 12 | 11:57:01:777AM | Test | Ok | EF4 Reverse PLC Test |
| 13 | 12:08:30:093PM | Test | Ok | EF1L Forward PLC Test |
| 14 | 12:16:04:660PM | Test | Ok | EF1L Reverse Test |
| 15 | 12:51:01:367PM | Test | Ok | OH1 Forward PLC Test |
| 16 | 01:00:02:893PM | Test | Ok | OH1 Reverse PLC Test |
| 17 | 01:07:59:880PM | Test | Ok | OH2U Forward PLC Test |
| 18 | 01:14:41:787PM | Test | Ok | OH2U Reverse PLC Test |
| 19 | 01:21:16:853PM | Test | Ok | OH2L Forward PLC Test |
| 20 | 01:29:06:980PM | Test | Ok | OH2L Reverse PLC Test |
| 21 | 01:35:30:123PM | Test | Ok | EF1U Forward PLC Test |
| 22 | 01:42:23:830PM | Test | Ok | EF1U Reverse PLC Test |
| 23 | 02:11:54:467PM | Test | Bad | EF$ Double Swing Control System Test |
| 24 | 02:21:12:140PM | Test | Ok | EF4 Double Swing with Power |
| 25 | 02:31:15:643PM | Test | Ok | OH Commutation Test |
| 26 | 02:41:29:553PM | Test | Ok | EF Commutation Test |
| 27 | 03:11:01:643PM | Test | Bad | EF Commutation Test for Bob G. magnetics tests |
| 28 | 03:18:27:040PM | Test | Ok | EF Commutation Test for Bob G. magnetics test |
| 29 | 04:48:43:713PM | Test | Ok | |
| 30 | 05:05:17:627PM | Test | Ok | |