| Physics Operator Comments |
| Jun 26 2009 10:02:53:770AM | 1090626004 | Steve Wolfe |
Shot#4: drop pre-puff to 19ms, kill pg3 in seg2
fizzle , not surprising
I think we may have lost a flux loop on shot#3
Need to check more carefully before next shot.
|
| Jun 26 2009 10:39:13:097AM | 1090626005 | Steve Wolfe |
Shot#5: BP17_JK died during shot#3 or earlier, appeared to fix itself
for shot#4, but Bob will zap before shot#5.
fizzle
next: drop pg4 a bit more.
|
| Jun 26 2009 11:02:56:153AM | 1090626006 | Steve Wolfe |
Shot#6: drop pg4 from 19 to 16ms.
plasma to 120ms
Nice looking startup. no hesitation
It only gets to 350ka by .1sec according to the rogowski
EFIT still looks bizarre, but I don't see any
high chisq. It claims to be way inside and have
xpoints near the inner wall. I don't see anything broken
in inputs or demands; loop voltage is ~5volts, the problem seems
to be that the current is so low at seg switch, and I don't
see why that is.
Next: drop pg4 some more and go again
|
| Jun 26 2009 11:20:08:770AM | 1090626007 | Steve Wolfe |
Shot#7: drop pg4 from 16 to 13ms.
plasma to .5 sec, overshoots 600ka and comes back
Runs diverted, but left gap seems to be shrinking
We are puffing a little gas, density is only 6e19.
Next: decrease nl04 from 7e19 to 5e19
|
| Jun 26 2009 11:30:36:320AM | 1090626008 | Steve Wolfe |
Shot#8: decrease nl04 from 7e19 to 5e19
plasma to 700msec. density rises after .45sec
Strike seems to be rather high on the outer plate;
of course, that could be related to the f23 being dead.
Next: Increase Ip back to 750ka, drop zxl
|
| Jun 26 2009 11:43:21:230AM | 1090626009 | Steve Wolfe |
Shot#9: Increase Ip back to 750ka,
drop zxl[.244] from +.00347 to -.003
and flattop value from -.01 to -.015
fizzle, poor burnout, pressure rising after breakdown.
Next: drop pg4 another 2ms
|
| Jun 26 2009 12:02:03:427PM | 1090626010 | Steve Wolfe |
shot#10: drop pg4 from 13 to 11ms
plasma to 880msec, closed gate valves again
Still getting a big density rise at 0.66sec
Strike point did come down according to efit.
Next: repeat, enable Ar puff 50msec
|
| Jun 26 2009 12:08:45:147PM | 1090626011 | Steve Wolfe |
shot#11:repeat, enable Ar puff 50msec at 300ms (pg1)
fizzle. Not surprising considering the levels of junk on the rga.
Next: pg4 to 10ms
|
| Jun 26 2009 12:24:58:500PM | 1090626012 | Steve Wolfe |
shot#12:pg4 to 10ms, enable Ar puff 50msec at 300ms (pg1)
fizzle. Still looking dirty. Pressure still rising after bd
Next: repeat
|
| Jun 26 2009 12:37:17:503PM | 1090626013 | Steve Wolfe |
shot#13: repeat
and another fizzle, but this one got some
current and moved outside;
ece gate valve is closed, but I think it hit outboard.
next: pg4 back up to 12ms
|
| Jun 26 2009 01:19:00:863PM | 1090626014 | Steve Wolfe |
Shot#14: pg4 back up to 12ms
another fizzle, gets to 50ka, hits earlier.
next: pg4 to 15ms
|
| Jun 26 2009 01:18:14:067PM | 1090626016 | Steve Wolfe |
Shot#16:Increase bzdot: V_ef3[.02,.026] from [2550,2200] to [2800,2500]
fizzle, very similar, a little longer and a little more current.
still hitting outside, ece opened that time and confirms moving out,
terminating outside.
|
| Jun 26 2009 01:34:38:400PM | 1090626017 | Steve Wolfe |
Shot#17: Adjust rcur waveform to start at .50m (.001,.010sec),
go to .63 at .020 sec, sort of like what the predictor does.
plasma to .88sec. Startup looks pretty good, not clear if
the waveform hack mattered or not. Phys_aout still oscillating
through seg1. Leave rcur as is for a shot or two. Play with seg2
|
| Jun 26 2009 01:36:27:447PM | 1090626017 | Steve Wolfe |
Shot#17: Adjust rcur waveform to start at .50m (.001,.010sec),
go to .63 at .020 sec, sort of like what the predictor does.
plasma to .88sec. Startup looks pretty good, not clear if
the waveform hack mattered or not. Phys_aout still oscillating
through seg1. Leave rcur as is for a shot or two. Play with seg2
Bob reports a partial flux loop needs zapping.
|
| Jun 26 2009 01:57:52:877PM | 1090626018 | Steve Wolfe |
Shot#18: Move rxl in to -.005
p0 over 1.2e-6 at init
fizzle. hardly any current. zmeter rises (no burnout)
Next: drop pg4?
|
| Jun 26 2009 02:12:22:930PM | 1090626019 | Steve Wolfe |
Shot#19: pg4 from 15 to 11ms
rxl at -.005
fizzle. got a tiny bit of current and a bounce (halpha) at 15msecc.
rcur trace indicates probably inside; no signal on ece.
zmeter still high and climbing. Bz rising between 15 and 20msec,
but phys_aout error signal is negative after 12ms; maybe should undo
ef3 change made on shot 16, but I think this fizz was just too dirty
to survive regardless. Pressure is rising after breakdown.
Next: drop pg4 to 10msec
|
| Jun 26 2009 02:23:02:933PM | 1090626020 | Steve Wolfe |
Shot#20: drop pg4 to 10msec
rxl still at -.005
fizzle. little more current, hits something at 16msec
no ece signal, maybe still just too cold. zmeter rising
so is pressure.
Next: undo v_ef3 programming from shot#16
|
| Jun 26 2009 02:39:06:440PM | 1090626021 | Steve Wolfe |
Shot#21: V_ef3[.02,.026] from [2800,2500] to [2550,2200] (back where it was)
plasma to .95 sec, rxl seems to have moved in a bit.
startup looks decent, minimal burnout on halpha, zmeter, but it goes.
Still getting a major density increase, this time around .72 sec
and nl04 is .7 to .8e20 before that with no gas puffing.
Next: repeat
|
| Jun 26 2009 02:44:59:973PM | 1090626022 | Steve Wolfe |
Shot#22: repeat
p0=1.6e-6 at init
fizzle, very small current, short, moves in I think
Next: repeat
|
| Jun 26 2009 03:05:51:967PM | 1090626023 | Steve Wolfe |
Shot#23: repeat
p0=1.0e-6 at init
plasma to 1.3sec
very shaky startup, almost scrunched inboard,
then swings out before it catches. breakdown was a little late 6.6ms
density excursion happens at 1sec.
Next: repeat
|
| Jun 26 2009 03:09:59:873PM | 1090626024 | Steve Wolfe |
Shot#24: repeat
p0=1.4e-6 at init
fizzle, of course. Better luck next time.
|
| Jun 26 2009 03:25:20:287PM | 1090626025 | Steve Wolfe |
Shot#25: repeat
p0=.95e-6 at init
FIZZLE. Thought that would go!
got a bit of current. bd a little later, after 7msec
next: raise pg4 to 14msec
|
| Jun 26 2009 03:39:34:557PM | 1090626026 | Steve Wolfe |
Shot#26: raise pg4 to 14msec
p0=7e-7 at init
plasma to 1.4sec, can't make it into rampdown!
breakdown back to 5 to 6 msec, some hesitation between
10 and 20msec. Halpha burnout good, zmeter lumpy.
density rise at 1.05sec this time.
Next: drop pg4 to 12msec
|
| Jun 26 2009 03:50:02:140PM | 1090626027 | Steve Wolfe |
Shot#26: drop pg4 to 12msec
p0=1.3e-6 at init
fizzle, bd at 6.5ms
Next: ic_ef4 to -1280
|
| Jun 26 2009 04:05:39:300PM | 1090626028 | Steve Wolfe |
Shot#27: ic_ef4 from -1270 to -1280
p0= 8.7e-7 at init
plasma to 1.41sec.
density lump at .79 coincides with clear injection on bolo
breakdown at 6msec,some wobbles in startup. I'm not sure if
the new rcur waveform is doing anything or not. Hesitation
between 10 and 15msec is worrisome, that may be related.
Next: raise Ip to 1MA
|
| Jun 26 2009 04:14:45:553PM | 1090626029 | Steve Wolfe |
Shot#29: raise Ip to 1MA, nl04 to 0.6e20;
p0=1.5e-6 at init
fizzle. got a little current, bd 6msec, zmeter rising
Bz[-.005] a little lower this time. Did I really load previous tweak?
Next: repeat
|
| Jun 26 2009 04:33:27:093PM | 1090626030 | Steve Wolfe |
Shot#30: raise Ip to 1MA, nl04 to 0.6e20;
p0=8.9e-7 at init
plasma to 1.52sec, into rampdown; vertical problem near
the end but I think it was caused by injection. OH1 and EF1
are on their rails.
Most likely that's going to be the last one, but we'll try
Next: ramp down a little earlier
|
| Jun 26 2009 04:46:32:207PM | 1090626030 | Steve Wolfe |
Shot#31: ramp Ip down from 1.4 sec
Pressure is hanging up above 5e-6 15 minutes after the shot.
This isn't coming back by 17:00. Shut it down for the day.
Leave a semi-good one on the drum.
|
| System Availability |
| Jun 26 2009 09:02:13:640AM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Power off, no hazard present. | May 30 2008 01:59PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | no | Pumped down, cold, ready to test | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|
| Jun 26 2009 11:38:37:403AM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Power off, no hazard present. | May 30 2008 01:59PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|
| Jun 26 2009 11:51:25:517AM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Power off, no hazard present. | May 30 2008 01:59PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|
| Jun 26 2009 03:44:23:700PM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Computer system problem, the lower freq. 16 channels are ready. | Jun 26 2009 03:37PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|
| Jun 26 2009 03:57:01:453PM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Computer system problem, the lower freq. 16 channels are ready. | Jun 26 2009 03:37PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|
| Jun 26 2009 04:09:39:787PM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Computer system problem, the lower freq. 16 channels are ready. | Jun 26 2009 03:37PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|
| Jun 26 2009 04:22:07:107PM |
| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change | | Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes | | BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan | | Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke | | Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby | | CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker | | Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard | | CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan | | D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe | | Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar | | Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte | | Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry | | Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry | | DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung | | ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer | | FRC-ECE | no | Computer system problem, the lower freq. 16 channels are ready. | Jun 26 2009 03:37PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips | | G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland | | Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby | | GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt | | GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben | | H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar | | HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow | | Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice | | Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice | | HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt | | ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin | | ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin | | ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin | | Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg | | LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar | | Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke | | McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry | | Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt | | MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard | | MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard | | MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott | | Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore | | Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby | | NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry | | PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab | | Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard | | Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe | | Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby | | Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby | | Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby | | Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby | | Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby | | Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard | | Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard | | Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard | | Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard | | Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar | | Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard | | Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard | | Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick | | Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin | | TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray | | TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma | | TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma | | Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf | | XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |
|