| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change |
| Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | sears,snipes |
| BES | no | vertical array of six views at R ~ 87.3 cm, radial array of three views out to R ~ 89 cm, both at outboard midplane. Three discrete fiber views of beam at R ~ 70.0, 76.5 and 82.5 cm. | Jun 10 2009 10:21AM (twf) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan |
| Bolometers | yes | 2pi-diode online only. | Jun 22 2009 10:26AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke |
| Boronization | no | Bottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel Access | May 30 2008 02:25PM (dekow) | Jim Irby | Boronization | dekow,irby |
| CNPA | no | Single channel CNPA available as of 12/1707 | Jun 10 2009 10:22AM (twf) | Ron Parker | Compact Neutral Analyzer | parker |
| Cryopump - Upper Divertor | no | external cryopump hardware removed from machine --- system is safe | May 30 2008 01:48PM (irby) | Brian LaBombard | Upper Divertor Cryopump | irby,labombard |
| CXRS | no | The pedestal toroidal array was installed, spatially and absolutely calibrated. There are 10 chords intersect the beam at the major_R_range=[74.2:86.3]cm. Spatial resolution: 1.2 cm. The F-top poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[67.8:91.0]cm. Spatial resolution: 1.22 cm. | Jul 03 2008 03:06PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan |
| D Alpha | no | \ha2_bright and \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 are available | Jun 04 2008 09:17AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe |
| Dalsa | no | poses no safety hazard for people working around the machine | May 30 2008 01:54PM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar |
| Disruption Mitigation | no | safely disabled; ready to be dismantled | May 28 2008 10:22AM (granetz) | Robert Granetz | Gas Jet | granetz,whyte |
| Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry |
| Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry |
| DNB | no | power locked & tagged out; gate valve disabled | May 28 2008 10:03AM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung |
| ECDC | no | 6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel Activity | Jun 10 2009 02:35PM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer |
| FRC-ECE | no | Computer system problem, the lower freq. 16 channels are ready. | Jun 26 2009 03:37PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | phillips |
| G-Side Ratiomatic | yes | Gauge installed. Controlleer is on. | Jun 24 2009 10:00AM (toland) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland |
| Glow Discharge | no | 6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel Access | Jun 10 2009 01:47PM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby |
| GPC | yes | Operational, but NOT CALIBRATED. Ch 1 seems low, others reasonable. | Jun 26 2009 08:25AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt |
| GPC2 | yes | Operational, but NOT CALIBRATED | Jun 26 2009 08:26AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt |
| GPI | no | Neither the Xpt-view nor the midplane-view camera is operational. | Nov 26 2007 04:25PM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben |
| H/D | yes | poses no safety hazard for people working around the machine | Jun 18 2009 01:04PM (marmar) | Earl Marmar | H/D Ratio | marmar |
| HEAT | no | Disconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work. | Jun 04 2008 12:24PM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow |
| Hirex Jr | yes | Hirex-Jr has been installed and tested | Jun 17 2009 11:54AM (rice) | John Rice | High Resolution X-Ray | ince,rice |
| Hirex Sr | no | Hirex-Sr has been removed from the cell and is in temporary storage | May 30 2008 01:48PM (ince) | John Rice | High Resolution X-Ray | ince,rice |
| HXR | no | In safe mode (high voltage turned off) | May 27 2008 09:19PM (schmidt) | Ron Parker | Hard X-Ray Array | parker,schmidt |
| ICRF D-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. | May 28 2008 08:16AM (ylin) | Steve Wukitch | D-port antenna | wukitch,ylin |
| ICRF E-Antenna | no | Transmission line disconnected. HV tagged out. Safe for machine entry. FFT out | May 28 2008 08:17AM (ylin) | Steve Wukitch | E-port antenna | wukitch,ylin |
| ICRF J-Antenna | no | HV tagged. Safe for machine entry. loop dissembly started. | May 28 2008 08:17AM (ylin) | Steve Wukitch | J-port antenna | wukitch,ylin |
| Lower Hybrid | no | Breaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted. | May 28 2008 09:47AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg |
| LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar |
| Ly-alpha | no | | Jun 17 2009 03:43PM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke |
| McPherson | no | Rolled back | Jun 17 2009 03:43PM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry |
| Michelson | yes | Operational. NOT RECALIBRATED | Jun 26 2009 11:25AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt |
| MKS | no | Power to all gauges is turned off. | Jun 04 2008 01:25PM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard |
| MLP | no | Initial tests on the A-port scanning probe went well. We need to take care of some control glitches that caused some component failures. | May 30 2007 08:01PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard |
| MSE | no | As of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB. | Jun 10 2009 10:34AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott |
| Neutrons | yes | Neutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma. | Jun 10 2009 10:35AM (fiore) | Catherine Fiore | Neutron Detectors | fiore |
| Neuts and Hards | yes | Operational --- Uncalibrated and needs to be positioned at port | Jun 25 2009 05:08PM (irby) | Jim Irby | X-Ray/Neutron Detector at K-Hor | irby |
| NINJA | no | System is diabled. House air to all pneumatic valves is disconnected. | Jun 04 2008 01:26PM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry |
| PCI | no | Both HeNe and CO2 lasers have been shutdown. System is safe. | May 30 2008 01:58PM (lianglin) | Miklos Porkolab | Phase Contrast Imaging | edlund,lianglin,ntsujii,porkolab |
| Penning Gauges | no | All HV supplies are turned off and unplugged | Jun 02 2008 01:09PM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard |
| Plasma TV | no | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jun 04 2008 09:18AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe |
| Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby |
| Power - Alternator Air Switch | yes | Checked and Operational as of 06/18/09 | Jun 19 2009 08:04AM (irby) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby |
| Power - PEI | yes | Operational ---- ECDC running as required | Jun 19 2009 08:06AM (irby) | Gary Dekow | PEI System | cochran,dekow,dterry,irby |
| Power - TMX | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby |
| Power Systems | yes | Checked out and ready for Magnet Tests as of 06/18/09 | Jun 19 2009 08:07AM (irby) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby |
| Probe Array - ISD | no | Power supplies are off. All cables are unplugged at the F-port rack. | Jun 02 2008 01:10PM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard |
| Probe Array - LH | no | All power supplies are off. Cables are unplugged at the A-port rack. | Jun 02 2008 01:10PM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard |
| Probe Array - OSD | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array | labombard |
| Probe Array - UDIV | no | All power supplies are off. Cables are unplugged at the F-port rack. | Jun 02 2008 01:11PM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard |
| Reflectometer | no | Disconnected | May 30 2008 01:47PM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar |
| Scanning Probe - ASP | no | Probe is retracted behind gatevalve. Air lines are disconnected. Probes cables disconnected at A-port rack. | Jun 02 2008 01:14PM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard |
| Scanning Probe - FSP | no | Probe is retracted fully. Air lines are disconnected. Probe cables disconnected at F-port rack. | Jun 02 2008 01:13PM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard |
| Scanning Probe - WASP | no | Probe cables are disconnected at F-port rack. | Jun 02 2008 01:17PM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick |
| Sparker | yes | Sparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasma | Jun 18 2009 01:01PM (irby) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin |
| TCI | yes | System restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma. | Jun 18 2009 09:15AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray |
| TS - Core | no | Expected availability: week of June 29 | Jun 24 2009 01:31PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jwhughes,yma |
| TS - Edge | no | Expected availability: week of July 20 | Jun 24 2009 01:32PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jwhughes,yma |
| Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf |
| XTOMO | yes | cables attached, DAQ test run, ready for first plasma | Jun 17 2009 03:42PM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |