Alcator C-Mod Run 1090715 Information

Back to runs

Miniproposals
Miniproposal:557
Date Filed: 7/13/2009
Title:Commisioning of new divertor heat flux diagnostics
First Author:Brian Labombard
Session Leader:Brian Labombard (shots 1-36)

Operators
Session leader(s):Brian Labombard
Physics operator(s):Ian Hutchinson
Engineering operator(s):Andy Pfeiffer,Sam Pierson,Gary Dekow

Engineering Operator Run Comment
automatically entered by signon - please replace with real comment

Session Leader Plans
Entered: Jul 15 2009 08:42:04:870AM
Author: Brian Labombard
Run Plan for 1090715

MP#557 "Commissioning of new divertor heat flux diagnostics"

Goal
A new set of heat-flux instruments was installed to diagnose C-Mod's lower divertor.
We wish to test and optimize the performance of these diagnostics, with particular focus on
examining the heat-flux footprint around the outer divertor strike point. We also wish to
condition-up the scanning probes, which requires some careful gap programming and repeated
shots.

Approach
Dial-up some standard lower-single null discharges with controlled inner/outer gaps but
also with some control on the outer divertor strike point location. The latter may be
accomplished by preprogramming the boundary shape. However, it is more desirable to
implement a feedback control of the strike-point position, if possible.
We will start by taking a series of nearly identical discharges with stationary or slow sweeps
of the outer divertor strike-point, watching the behavior of the heat-flux sensors. A coarse
density scan may be performed if things go well. Some cell access may be required to debug
systems. We should start with 0.8 MA discharges, but then push to 1.0 MA to increase heat
flux signals.

Key Diagnostics: Divertor heat-flux sensors, divertor IR system, all scanning probe systems
(ASP, FSP, WASP),

Desired but not required: edge Thomson, gas-puff imaging (diodes and fast camera)

We may need multiple cell entries to debug diagnosics.

Plan
Start with a recent 0.8 MA, 5.4 tesla discharge (or something close and tweak it).
- Left gap ~1.2 cm, right gap ~1.6 cm
- Outer divertor strike point on the lower part of tile number 2.
- Set NL04 = 0.6e20 m^-2
- If NINJA is available, fill to 10 PSI D2
- ICRF - may piggyback after 1.2 on some shots

- Fixed Strike Points -
A. NL04 ~ 0.6, Ip = 0.8 MA - 5 shots
Adjust gaps as necessary to optimize scanning probe
targeting. Try to hold outer divertor strike point at a fixed location during
the shot - the lower half of tile number two. We want to hold the heat flux footprint
on the outer divertor fixed so that the calorimeter delta-Ts (before and after shot)
can be used to map it out.

Assess temperature rises. We may want to change to 1.0 MA. If so, we will need to take more
shots to set this up. Assuming that we stay at 0.8 MA, do the following:

- Shot-by-Shot Strike Point Scan -
B. NL04 ~ 0.6, Ip = 0.8 MA - 5 shots
Slowly march the strikepoint up the divertor plate on a shot-by-shot basis - about
a centimeter in the vertical position of the strike point per shot.

C. NL04 ~ 0.8, Ip = 0.8 MA - 5 shots
Repeat C at this new density

D. NL04 ~ 1.0, Ip = 0.8 MA - 5 shots
Repeat C at this new density

E. NL04 ~ 1.2, Ip = 0.8 MA - 5 shots
Repeat C at this new density

F. NL04 ~ 0.6, Ip = 1.0 MA - 5 shots
Repeat C at this new density and current

Physics Operators Plans

Session Leader Summaries
Entered: Jul 15 2009 11:03:21:960PM
Author: Brian Labombard
Run Summary for 1090715

MP#557 "Commissioning of new divertor heat flux diagnostics"

This was a productive run. The primary goal was to develop discharges with controlled
outer divertor strike point and to use this to test and optimize embedded heat flux
sensor signals. Ian managed to implement some kind of feedback control of the
outer divertor strike point in just a few shots. By shot 7 we had a 0.8 MA LSN discharge
with the strike point roughly stationary on Langmuir probe #4 on the outer divertor and
were confident enough to start exercising the ASP, FSP and WASP systems. (As an aside,
we discovered that the coil polarity on the A-port WASP drive was reversed. We corrected
it during a cell entry.) Unfortunately, surface heat flux sensor number 4 and 10 decided to
die early, leaving us with only 4 good remaining sensors: 1, 3, 5 and 9. And with
the strike point on Langmuir probe #4, surface sensor #5 is just slightly below the
heat flux footprint. All the while, Jim Terry and Josh Payne were busily trying to get the
IR camera up and running. View alignment was the primary obstacle, followed by the lack of
a trigger. Numerous cell entries were required. Anyway, we pushed on with trying to
fix the strikepoint onto probe #1. This proved to be more difficult, requiring
many tweaks and shots without firing the scanning probes, just to be safe.
By shot 21 we started poking the probes at a reasonable discharge with strike points
hovering around probes 1 and 2. On shot 22 the IR camera demonstrated success - a
spectacular movie of strike point heat on the J-divertor ramped tiles! Hat's off
to Jim Terry and Josh Payne for cobbling this together under the pressure. Still, with the
strike point on 1-2, not a lot of heat was arriving on the good surface heat flux
sensors. The calorimeters appeared to respond ok (11 of 14 working), but the timescales look
a bit long - something that will need more analysis. Finally, we ran
shots with the strikepoint on probe#2 (shots 28 and beyond). This lead to some
nice reproducible temperature rises on surface sensor #5 during the shot, roughly 300 C.
These should provide a cross-calibration with the IR system. Having done the strikepoint
control part of the MP, we started varying the density. Shot 35 was the first attempt
at this (NL04 ~ 0.8e20). We will pick up on this in tomorrow's run.
___________________________________________________________________________________
Shot log

1-no power test. ASP, FSP scanning at 0.62s
2-LSN, NL04=0.58, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point sweeps up divertor plate. Analysis jobs not running ("wrong ELF class: ELFCLASS32")

Start strike-point control (target: probe#4)

3-LSN, NL04=0.6, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point sweeping up plate. Surface TC sensor #4 is now dead.
4-LSN, NL04=0.6, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Slower strike point sweep up plate.
5-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point on probe #4 after 0.75s. SSEP is now more negative, but ramps up after 1 s.
6-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point on probe #4. SSEP at -2 cm, flat.
7-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(0), FSP(-15), WASP(rho=5) scanning at 0.7, 0.9, 1.1s
8- no power
9-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(+2), FSP(-10), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
Strike point steady on probe#4
10- no probes scanning
Strike point steady on probe#4
11-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(0), FSP(-10), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
Strike point steady on probe#4
12-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(+2), FSP(-7), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
ASP at separatrix, FSP could be deeper, WASP position uncertain.
13-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(+2), FSP(-5), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
ASP near sep., FSP near sep. cleaning up, WASP scanning the wrong direcion!
14-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(+2), FSP(-5), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
ASP near sep. on first scan, FSP near sep., WASP scanning the wrong direction!

Try strike point control on probe#1

15-LSN, NL04=0.69, Ip=0.8, Bt=5.3, no probes scanning.
Asking for strike point on tile#1 -- disrupts at 1.4s -- ends up limited on the outer divertor shelf.
16-LSN, lost NL04, Ip=0.8, Bt=5.3, no probes scanning.
17-LSN, NL04=0.59, Ip=0.8, Bt=5.3, no probes scanning.
Strike point hovers around probes #1 and 2.
18-LSN, NL04=0.59, Ip=0.8, Bt=5.3, no probes scanning.
Strike point hovers around probes #1 and 2.
19-LSN, NL04=0.6, Ip=0.8, Bt=5.3, no probes scanning.
Max plasma pressure on probe#2.
20-LSN, NL04=0.62, Ip=0.8, Bt=5.3, no probes scanning.
Max plasma pressure on probe#2.
21-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(-5), WASP(rho=5) scanning at 0.7, 0.9, 1.1s
ASP and WASP need to be deeper.
22-fizzle
23-LSN, NL04=0.62, Ip=0.8, Bt=5.3, No probes scanning.
Divertor IR records first heatflux footprint on this shot.
24-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(-2), WASP(rho=2) scanning at 0.7, 0.9, 1.1s, FSP(-5) at 1.1s
ASP,FSP,WASP need to be deeper.
25-LSN, NL04=0.6, Ip=0.8, Bt=5.3, ASP(0), WASP(rho=0) scanning at 0.7, 0.9, 1.1s, FSP(-1) at 1.1s
ASP,FSP,WASP still need to be deeper.
26-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+2), WASP(rho=-1) scanning at 0.7, 0.9, 1.1s, FSP(+2) at 1.1s
ASP-first scan at sep., FSP-could be deeper, WASP- at sep.
27-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+2.5)WASP(rho=-1) scanning at 0.6, 0.9, 1.2s, FSP(+6) at 1.2s
Good data. IR camera recorded images.

Change strike point to probe#3
28-LSN, NL04=0.61, Ip=0.8, Bt=5.3, No probes scanning
strike point on probe#3
29-fizzle

30-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-1) scanning at 0.6, 0.9, 1.2s, FSP(-5) at 1.2s
Strike point on probe#3
ASP-excellent, cleans up on first scan
WASP - good
FSP- scanning at wrong time - should have been 0.9s
31-fizzle
32-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-4) at 0.9s
ASP-excellent
WASP - no data. cPCI error
FSP- no data. cPCI error
33-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-4) at 0.9s
ASP-excellent
WASP - excellent
FSP- could be deeper
34-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-3) at 0.9s
ASP - in fluctuation mode - Easts floating, Wests sweeping
WASP - in fluctuation mode - Easts floating, Wests sweeping
FSP - in fluctuation mode - Easts floating, Wests sweeping
34- IR camera image of this shot, with sensor locations on Tile#3 lighting up.
Surface TC#5 on tile#3 sees 300 C rise. This could be a good shot for cross-calibration.

Go to NL04~0.8
35-LSN, NL04=0.8, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-4) at 0.9s
ASP-could be deeper
WASP - could be deeper
FSP- too deep
36- fizzle

Physics Operator Summaries
Entered: Jul 15 2009 05:03:12:737PM
Author: Ian Hutchinson
Strkpsi control for testing of the divertor calorimetry.

Summary
_______


Strkpsi control was implemented successfully, relaxing the control of
zxl. For control at low positions it was necessary to draw the rxl ramping to
about -2cm (still under PCS control) by the end of the shot. This
provided the ability to meet the demand for a low strike point without
excessively moving the x-point down.


Scorecard
---------

 
  Shot,Duration(s),Ipmax(MA),Result  Shot,Duration(s),Ipmax,Result
  |   01   0.000   0.002   Dud     |   02   1.970   0.825   Plasma  |
  |   03   1.969   0.823   Plasma  |   04   1.968   0.818   Plasma  |
  |   05   1.967   0.812   Plasma  |   06   1.966   0.813   Plasma  |
  |   07   1.966   0.818   Plasma  |   08   0.000   0.002   Dud     |
  |   09   1.311   0.824   Plasma  |   10   1.968   0.823   Plasma  |
  |   11   1.967   0.821   Plasma  |   12   1.966   0.820   Plasma  |
  |   13   1.967   0.819   Plasma  |   14   1.967   0.821   Plasma  |
  |   15   1.447   0.826   Plasma  |   16   1.584   0.830   Plasma  |
  |   17   1.964   0.826   Plasma  |   18   1.965   0.828   Plasma  |
  |   19   1.964   0.829   Plasma  |   20   1.964   0.830   Plasma  |
  |   21   1.963   0.835   Plasma  |   22   0.000   0.051   Fizzle  |
  |   23   1.964   0.834   Plasma  |   24   1.964   0.833   Plasma  |
  |   25   1.963   0.833   Plasma  |   26   1.964   0.832   Plasma  |
  |   27   1.964   0.830   Plasma  |   28   1.962   0.829   Plasma  |
  |   29   0.000   0.086   Plasma  |   30   1.963   0.829   Plasma  |
  |   31   0.000   0.054   Fizzle  |   32   1.965   0.830   Plasma  |
  |   33   1.963   0.829   Plasma  |   34   1.964   0.826   Plasma  |
  |   35   1.947   0.819   Plasma  |   36   0.000   0.052   Fizzle  |
 
*** Consider increasing shotmax.      36
Date 1090715:  36 shots.  31 plasmas.   3 fizzles.   2 duds.   0 System Error.
        (Plasma = Ip gt 60.0 kA   Dud = H_alpha lt  0.40 V)
Total plasma duration: 57.39 s (exceeding -100 kA)


The duds were deliberate gas and no-power shots. Fizzles appeared to
be vertical problems.

Session Leader Comments
Jul 15 2009 09:23:27:573AM1090715002Brian Labombard2-LSN, NL04=0.58, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point sweeps up divertor plate. Analysis jobs not running ("wrong ELF class: ELFCLASS32")
Jul 15 2009 09:35:06:043AM1090715003Brian Labombard 3-LSN, NL04=0.6, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point sweeping up plate. Surface TC sensor #4 is now dead.
Jul 15 2009 09:49:51:793AM1090715004Brian Labombard4-LSN, NL04=0.6, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Slower strike point sweep up plate.
Jul 15 2009 10:00:45:090AM1090715005Brian Labombard5-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point on probe #4 after 0.75s. SSEP is now more negative, but ramps up after 1 s.
Jul 15 2009 10:10:23:917AM1090715006Brian Labombard6-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP, FSP, WASP not scanning.
Strike point on probe #4. SSEP at -2 cm, flat.
Jul 15 2009 11:36:09:247AM1090715009Brian Labombard9-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(+2), FSP(-10), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
Strike point steady on probe#4
Jul 15 2009 11:08:26:870AM1090715010Brian Labombard10 - No probes scanning - workstation died and I couldn't check the setup.
Jul 15 2009 11:36:43:060AM1090715011Brian Labombard11-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(0), FSP(-10), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
Strike point steady on probe#4
Jul 15 2009 11:37:21:637AM1090715012Brian Labombard12-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(+2), FSP(-7), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
ASP at separatrix, FSP could be deeper, WASP position uncertain.
Jul 15 2009 12:18:59:450PM1090715013Brian Labombard13-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(+2), FSP(-5), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
ASP near sep., FSP near sep. cleaning up, WASP scanning the wrong direction!
Jul 15 2009 12:19:45:777PM1090715014Brian Labombard14-LSN, NL04=0.63, Ip=0.8, Bt=5.3, ASP(+2), FSP(-5), WASP(rho=2) scanning at 0.7, 0.9, 1.1s
ASP near sep. on first scan, FSP near sep., WASP scanning the wrong direcion!
Jul 15 2009 12:20:31:307PM1090715015Brian Labombard15-LSN, NL04=0.69, Ip=0.8, Bt=5.3, no probes scanning.
Asking for strike point on tile#1 -- disrupts at 1.4s -- ends up limited on the outer divertor shelf
Jul 15 2009 12:44:27:810PM1090715017Brian Labombard17-LSN, NL04=0.59, Ip=0.8, Bt=5.3, no probes scanning.
Strike point hovers around probes #1 and 2.
Jul 15 2009 12:59:57:073PM1090715018Brian Labombard18 - a repeat of shot 17. No probes scanning.
Jul 15 2009 01:12:43:200PM1090715019Brian Labombard19-LSN, NL04=0.6, Ip=0.8, Bt=5.3, no probes scanning.
Max plasma pressure on probe#2.
Jul 15 2009 01:43:32:780PM1090715020Brian Labombard20-LSN, NL04=0.62, Ip=0.8, Bt=5.3, no probes scanning.
Max plasma pressure on probe#2.
Jul 15 2009 01:44:59:800PM1090715021Brian Labombard21-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(-5), WASP(rho=5) scanning at 0.7, 0.9, 1.1s
ASP and WASP need to be deeper.
Jul 15 2009 02:18:00:377PM1090715023Brian Labombard23-LSN, NL04=0.62, Ip=0.8, Bt=5.3, No probes scanning.
Strike point on probe#2.
Divertor IR records first heatflux footprint on this shot!
Jul 15 2009 02:32:57:640PM1090715024Brian Labombard24-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(-2), WASP(rho=2) scanning at 0.7, 0.9, 1.1s, FSP(-5) at 1.1s
ASP,FSP,WASP need to be deeper.
Jul 15 2009 02:45:11:563PM1090715025Brian Labombard25-LSN, NL04=0.62, Ip=0.8, Bt=5.3, ASP(0), WASP(rho=0) scanning at 0.7, 0.9, 1.1s, FSP(-1) at 1.1s
ASP,FSP,WASP still need to be deeper.
Jul 15 2009 03:02:13:347PM1090715026Brian Labombard26-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+2), WASP(rho=-1) scanning at 0.7, 0.9, 1.1s, FSP(+2) at 1.1s
ASP-first scan at sep., FSP-could be deeper, WASP- at sep.
Jul 15 2009 03:24:57:377PM1090715027Brian Labombard27-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+2.5)WASP(rho=-1) scanning at 0.6, 0.9, 1.2s, FSP(+6) at 1.2s
Good data. IR camera recorded images
Jul 15 2009 03:25:16:267PM1090715028Brian Labombard28-LSN, NL04=0.61, Ip=0.8, Bt=5.3, No probes scanning
strike point on probe#3
Jul 15 2009 04:21:08:140PM1090715032Brian Labombard32-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-4) at 0.9s
ASP-excellent
WASP - no data. cPCI error
FSP- no data. cPCI error
Jul 15 2009 04:48:11:423PM1090715033Brian Labombard33-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-4) at 0.9s
ASP-excellent
WASP - excellent
FSP- could be deeper
Jul 15 2009 04:48:48:390PM1090715034Brian Labombard34-LSN, NL04=0.61, Ip=0.8, Bt=5.3, ASP(+4), WASP(rho=-2) scanning at 0.6, 0.9, 1.2s, FSP(-3) at 0.9s
ASP - in fluctuation mode - Easts floating, Wests sweeping
WASP - in fluctuation mode - Easts floating, Wests sweeping
FSP - in fluctuation mode - Easts floating, Wests sweeping

Next: go to nNL04 ~ 0.8
Jul 15 2009 05:00:26:657PM1090715034Brian Labombard34- IR camera image of this shot, with sensor locations on Tile#3 lighting up.
Surface TC#5 on tile#3 sees 300 C rise. This could be a good shot for cross-calibration.

Physics Operator Comments
Jul 15 2009 08:50:50:963AMIan HutchinsonLoad from 1070714024.
Lower current to 0.8MA.
Right and left gaps are about 1.1cm. So move rcur in by 2mm.
nl04 to 0.6
Sest 9-12 to Ip ref.
Type in strkpsi.
Call
Zero values. Apply.
Controller. Make the keywords to be all the usual except. Wolfe says, strkpsi
instead of ZXL IN allnames. CALL.OK. Verify the rate? Put .98.
Reference points are Rstrk-.62, Zstrk=-.52m defaults.
Load. Save as home/hutch/scratch 1010.
Load from 1090714026 for a gas valve test. Load.
Jul 15 2009 08:52:55:213AM1090715001Ian HutchinsonGas puff only test. [Apparently not successful. PG5 not working.]

Load the proper shot from 1010.
Load.
Jul 15 2009 09:18:31:823AM1090715002Ian HutchinsonPlasma.


Turn on the strkpsi controller stepping up the proportional gain to 1.2 at 1s.
It turns off at 1.5s. Value is set at zero. Might be a bit high for Brian.
Lower the ZXL gain from max of 8, stepping down to 2 at 1s.
Load. Strange message about times. Acknowledge.
Jul 15 2009 09:34:48:150AM1090715003Ian HutchinsonPlasma. Looks as if strkpsi is doing something. It is pushed up slightly.

Double the gain on strkspi.
Reduce ZXL gain to low value after 1s.
Load. Adjusting matix load time message again.
Jul 15 2009 10:01:44:480AM1090715004Ian HutchinsonPlasma. Control seems slightly better.

ZXL gain to zero at .4s through 1.5s.
strkspsi gain to 5.
zcur to -15mm from -9mm to make more single null.
Jul 15 2009 10:04:23:277AM1090715005Ian HutchinsonPlasma. Obvious control of strkpsi later in shot.

Increase early gain of strkpsi. Decrease zxl early gain.
Increase zxu later in the shot to increase ssep.
Jul 15 2009 10:22:13:510AM1090715006Ian HutchinsonPlasma. Good control except for the OH1 crossover.


Tweak rcur out at .2s and .5s.
Tweak Ip rise. Load.
Jul 15 2009 10:30:44:433AM1090715007Ian HutchinsonPlasma. Runaways caused by initation bounce. Very early breakdown.

Tweak rxl out a bit at .5 to .6s.
Got the stupid message back and made incorrect timing of load.
So make the next a no power shot.
Jul 15 2009 10:41:34:277AM1090715008Ian HutchinsonNo power shot
Jul 15 2009 11:01:17:433AM1090715009Ian HutchinsonPlasma. Disrupts at 1.3s. Monstrous injection.

Lower zxl gain at .2s to avoid oscillation I hope.
Jul 15 2009 11:11:36:463AM1090715010Ian HutchinsonPlasma.

Increase PG3 in segment 1 to 30V, to try to minimize runaways.
Jul 15 2009 11:23:15:527AM1090715011Ian HutchinsonPlasma. Still runaways.


Increase fill puff to 17ms from 15ms.
Jul 15 2009 11:37:58:543AM1090715012Ian HutchinsonPlasma.

ICEF4 to -1300 from -1290A.
Jul 15 2009 11:50:43:543AM1090715013Ian HutchinsonPlasma. Runaways still.

Fill puff to 19ms.
Jul 15 2009 12:03:36:653PM1090715014Ian HutchinsonPlasma.

strk coordinates are .62, -.52. We want to move the strikepoint down by
4cm. So we use keywords Zsout=-.56 Rsout=.624. These are not rstrk. An unfortunate error of documentation.

Move the EF1 crowbar to .15s.

Load.
Jul 15 2009 12:24:41:810PM1090715015Ian HutchinsonPlasma disrupts at 1.44s. Shape is very strangely distorted in trying to
keep the strikepoint low. Nominal strkpsi is -1mm. (Versus about +1mm).

Get rid of keywords on strkpsi. Set p-value to -.1mm.
Install an RXL ramp to -.04 at 1.5s.
Jul 15 2009 12:35:13:497PM1090715016Ian HutchinsonPlasma disrupts in rampdown.
Zeros EF2L at 1s.

Back off on RXL ramp to peak at -.021.
Install some more gradual steps in the release of strkpsi
Jul 15 2009 12:47:49:810PM1090715017Ian HutchinsonPlasma ramps down.

Increase strkpsi to -1.5mm.
Make ef2byef4 -3000 from -2000 at >1s
Jul 15 2009 01:09:57:040PM1090715018Ian HutchinsonPlasma ramps down. Forgot to load. A repeat.

Load.
Jul 15 2009 01:29:46:997PM1090715019Ian HutchinsonPlasma.

Lower zxl at .25s.
Increase strkpsi gain to 6 from 5.
Enable argon.
Jul 15 2009 01:42:55:497PM1090715020Ian HutchinsonPlasma to rampdown.


Reduce RXL during first .7s.
Increase clearin by 5mm to 0.
Load.
Jul 15 2009 01:55:41:470PM1090715021Ian HutchinsonPlasma to rampdown.

The oscillation in the first .7s seems to be triggered by the turn on of EF4byEF2
Turn on more gradually. Also draw the ICEF4 to be less positive at .3s which
appears to be a related issue.
Tweak the clearin up at .25s
Jul 15 2009 02:13:43:707PM1090715022Ian HutchinsonFizzle for no obvious reason.
Jul 15 2009 02:38:39:250PM1090715024Ian HutchinsonPlasma.
Jul 15 2009 02:47:34:640PM1090715025Ian HutchinsonPlasma.

strkspi D to 1. Physics PID is then D=.001, P=6 (1/s). Should be a miniscule
effect.
Jul 15 2009 02:57:59:220PM1090715026Ian HutchinsonPlasma.
Jul 15 2009 03:19:35:503PM1090715027Ian HutchinsonPlasma.

Strkpsi to -.7mm. D to 3.
Adjust RXL in .4s time
Jul 15 2009 03:28:09:250PM1090715028Ian HutchinsonPlasma.


strkspi D to 6.
Jul 15 2009 03:44:02:390PM1090715029Ian HutchinsonVertical position error throws the plasma away at about 80kA.
Can't really see why.
Jul 15 2009 03:56:54:033PM1090715030Ian HutchinsonPlasma. Injection at .63s attributed to ASP.
Jul 15 2009 04:21:40:173PM1090715031Ian HutchinsonFizzle. Strong. Looks like a vertical problem.

Br offset to .0007 from .001.
Jul 15 2009 04:21:51:533PM1090715032Ian HutchinsonPlasma.
Jul 15 2009 04:39:30:360PM1090715033Ian HutchinsonPlasma.
Jul 15 2009 04:46:51:190PM1090715034Ian HutchinsonPlasma.

Raise nl04 to .8e20.
Jul 15 2009 05:00:49:503PM1090715035Ian HutchinsonPlasma.
Jul 15 2009 05:02:47:957PM1090715036Ian HutchinsonFizzle.

Engineering Operator Comments
ShotTimeTypeStatusComment
108:48:55:963AMTestBadGas test H
209:03:17:417AMPlasmaOk
309:16:45:040AMPlasmaOk
409:33:25:747AMPlasmaOk
509:49:25:090AMPlasmaOk
610:02:24:933AMPlasmaOk
710:15:10:463AMPlasmaOk
810:27:44:857AMPlasmaBadProgramming error
910:41:08:433AMPlasmaOk
1010:53:57:137AMPlasmaOk
1111:07:49:040AMPlasmaOk
1211:20:32:370AMPlasmaOk
1311:33:22:040AMPlasmaOk
1411:46:21:510AMPlasmaOk
1512:02:34:790PMPlasmaOk
1612:18:36:043PMPlasmaOk
1712:33:07:090PMPlasmaOk
1812:45:58:667PMPlasmaOk
1912:58:41:667PMPlasmaOk
2001:18:06:323PMPlasmaOk
2101:32:59:963PMPlasmaOk
2201:52:25:437PMPlasmaOk
2302:06:01:033PMPlasmaOk
2402:19:45:017PMPlasmaOk
2502:32:22:550PMPlasmaOk
2602:45:39:580PMPlasmaOk
2702:59:08:767PMPlasmaOk
2803:12:35:143PMPlasmaOk
2903:26:00:377PMPlasmaOk
3003:38:38:847PMPlasmaOk
3103:51:59:890PMPlasmaOk
3204:04:36:330PMPlasmaOk
3304:19:14:800PMPlasmaOk
3404:31:50:017PMPlasmaOk
3504:44:40:347PMPlasmaOk
3604:58:54:360PMPlasmaOk

System Availability
Jul 15 2009 08:48:33:073AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
BolometersyesMost systems collecting data but not calibrated. WB2 and WB1 not attached.Jul 07 2009 01:00PM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoBottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel AccessMay 30 2008 02:25PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoCyopump hardware is not yet reinstalled in the cell.Jul 14 2009 09:21PM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationnosafely disabled; ready to be dismantledMay 28 2008 10:22AM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnopower locked & tagged out; gate valve disabledMay 28 2008 10:03AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCno6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel ActivityJun 10 2009 02:35PM (dekow)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesThe lower freq. 16 channels are ready. Still need calibration and signal level adjustmentsJul 14 2009 12:15PM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Problem with controller - signal noisy.Jul 14 2009 09:11PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational, but NOT CALIBRATED. Ch 1 seems low, others reasonable.Jun 26 2009 08:25AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesOperational, but NOT CALIBRATEDJun 26 2009 08:26AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATnoDisconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work.Jun 04 2008 12:24PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-AntennanoTransmission line disconnected. HV tagged out. Safe for machine entry.May 28 2008 08:16AM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-AntennanoTransmission line disconnected. HV tagged out. Safe for machine entry. FFT outMay 28 2008 08:17AM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-AntennanoHV tagged. Safe for machine entry. loop dissembly started.May 28 2008 08:17AM (ylin)Steve WukitchJ-port antennawukitch,ylin
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data but processed data not in tree. WB1-LY not attached.Jul 07 2009 01:01PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonnoPumped down and awaiting good vacuum conditions to allow plasma testsJul 13 2009 10:08PM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. NOT RECALIBRATEDJun 26 2009 11:25AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesOperational --- Uncalibrated and needs to be positioned at portJun 25 2009 05:08PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCInoBoth HeNe and CO2 lasers have been shutdown. System is safe.May 30 2008 01:58PM (lianglin)Miklos PorkolabPhase Contrast Imagingedlund,lianglin,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyesOperational ---- ECDC running as required Jun 19 2009 08:06AM (irby)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesAs of 7/8/09, the 50, 60, 75 and 88 (baseband, lsb and usb) are available. The 140GHz channel and swept frequency channel are online but untested for their cutoff frequencies. The 110 is offlineJul 14 2009 02:30PM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasmaJun 18 2009 01:01PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - CoreyesMidplane channel is operational, but ***uncalibrated***Jul 14 2009 08:36AM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgenoExpected availability: week of July 20Jun 24 2009 01:32PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyescables attached, DAQ test run, ready for first plasmaJun 17 2009 03:42PM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke