Alcator C-Mod Run 1090807 Information

Back to runs

Miniproposals
Miniproposal:555
Date Filed: 5/29/2009
Title:PF Error Field Evaluation and Compensation
First Author:Steve Wolfe
Session Leader:Steve Wolfe (shots 1-29)

Operators
Session leader(s):Steve Wolfe
Physics operator(s):Earl Marmar
Engineering operator(s):Bill Parkin,Bill Byford,Ed Fitzgerald

Engineering Operator Run Comment
MP#555 PF Error field evaluation and compensation

Session Leader Plans
Entered: Aug 6 2009 01:18:27:267PM
Author: Steve Wolfe
Session Leader run plan for Friday, Aug 7, 2009
MP#555 PF Error field evaluation and compensation
SL: wolfe
PO: Marmar

This experiment will use the acoil in two different configurations;
engineering ops should be prepared to make the necessary tap changes. We will
begin with the taps in the standard +Dtop -Dbot -Jtop +Jbot
connection. Depending on results, we will probably change to 
+Bbot +Dtop -Gbot -Jtop about 1/3 of the way through the run.

This experiment will require low density but will probably have lots of
disruptions. While I would like to avoid runaways, I'm more concerned with
disruption recovery, so I recommend D2 pre-puff in B-top and substantial PG3
puff in seg1. 

Analysis of single coil data from 1090702 indicated significant changes in the
non-axisymmetric fields from several of the PF coils. Unfortunately, the
analysis is somewhat ambiguous with respect to both the magnitude and
orientation of the resultant field for typical shots. Two possible solutions
have been loaded into the \analysis::top.non_axi.model nodes in analysis trees
1090702333 and 1090702888. The former indicates we should expect smaller
amplitude (2/1) error field, but with orientation rotating from 2nd to 3rd
quadrant during the flattop, which makes the feedback compensation
problematic.  Possibly the present standard acoil configuration (+Dtop -Dbot
-Jtop +Jbot) will work later in the shot, if we can avoid a locked mode in the
early phase. The latter model predicts similar or larger amplitude to the old
calculation, but rotated by nearly 90 degrees, so that our normal compensation
configuration will be less effective. A better match would seem to be the
"rotated helical" configuration (+Bbot +Dtop -Gbot -Jtop). The major
difference between these models is in the contribution of the EF3L coil; in
one case this contribution is opposite to that of EF3U, so that the net error
is small, while this cancellation is not present in the other model.  The
plasma phase of this miniproposal will provide additional data to help resolve
this discrepancy.

1) Check intrinsic threshold [1-5 shots] 

We will begin by checking the intrinsic locking threshold on a 1MA, 5.4T, LSN
ohmic shot. Previously we have found the theshold for locking to be in the
range of nebar~1 to 1.5e20/m^3 (nl04~0.6 to 0.9e20). If the 1090702333
calculation is correct, we should expect to see a considerably lower
threshold, by about a factor of two, or more. Start with any recent 1MA LSN
shot, setting the initial target density to nl04=1e20/m^2, and program
negative density after 0.7sec to allow the density to fall. The a-coil should
be disabled for these shots.  If a locked mode comes in early, then increase
the early density and repeat. If no locked mode appears at the lowest
accessible density, then we should probably declare victory, leave the acoils
off, and quit, but we won't.  Instead we'll try raising the current to 1.2MA
and then to 1.35MA. Both models predict that ef3 and ef4 should generate
significant error-field, so higher current should provoke a locked mode, and
we can proceed to step 2.

Most likely, the intrinsic threshold will be about where it used to be,
6< nl04 < 9e19 at 1MA. This could indicate either that nothing has really
changed, despite the results of the measurements of 1090702, or it could
indicate the 1090702888 model is valid. To find out, we need to turn on the
acoil  

2) [2-5 shots] Test feedback compensation using original 2003 model, standard
   A-coil configuration.

Repeat the falling density shot with A-coil energized and B21_PROJ feedback
turned on, with waveform at zero as usual. Observe whether locking density
goes up or down. 

If the locking density decreases, then program a flat density just above the
locking value and repeat using the same feedback. Observe locking density and
time if any. Determine minimum flat density which does not lock using this
feedback.

3) [2-5 shots] Test feedback compensation using 1090702333 model
If the intrinsic locking density was significantly lower than 9e19, then
test the 1090702333 model; otherwise this model is probably ruled out, and we
can skip to step 4. 

With the acoil still in the old standard configuration
(+Dtop -Dbot -Jtop +Jbot) set up the B21_PROJ feedback with keywords 
SHOT=1090702333,ACOIL="+DTOP -DBOT -JTOP +JBOT". Set the target waveform to
zero (as it normally is). See whether the locking density goes up or down. 

If it goes down, run a flat density just above the locking threshold and
observe the time history, then reduce density and repeat. Note that it may be
necessary to keep the density higher early in the shot before the feedback
turns the acoil on.

4) [2-5 shots] Test feedback compensation using 1090702888 model
If the intrinsic locking density is nl04 < 4e19 then this model is probably
ruled out, but may as well try the alternate orientation anyway. 

Change A-coil tap configuration to [+Bbot +Dtop -Gbot -Jtop], and re-program
B21_PROJ feedback, using keywords SHOT=1090702888, ACOIl="+BBOT +DTOP -GBOT
-JTOP" . Be sure engineers update the patch panel configuration in the
Engineering Control widget. Then repeat falling density shot and observe
change in locking density. 

If the locking density is lower than the intrinsic value and the
minimum observed with the earlier feedback programming, then program a
flat density just above the observed locking value and repeat with the same
feedback. Determine the flattop density at which locking is avoided for the
full flattop. 

5) [2-5 shots] Assess variations to feedback 
Using the best feedback programming from steps 2-4 (which might involve a
change in the A-coil patch panel), program non-zero target values for the
B21_PROJ. Start with targets of +.0002T and -.0002T, and vary to reduce the
minimum locking density, if possible.

6) [3 shots] Assess compensation algorithm at higher current. 
If not already done in step 1, raise current to 1.2 or 1.3MA and repeat
falling density shot with best feedback. 


Physics Operators Plans
Entered: Aug 6 2009 04:58:38:670PM
Author: Earl Marmar
Engineering setup for Friday, August 7, 2009

MP#555 PF Error field evaluation and compensation
SL: Wolfe
PO: Marmar

Run begins at 09:00 and ends at 17:00

Power systems as on: 1090806031

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D Hybrid enabled (PG3)
leave NINJA as is Hybrid DISABLED

Enable gatevalves and shutters: ECE, VUV, Z-bolo

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): YES
ICRF(yes/no): no
LH(yes/no): no
DNB(yes/no): no
Cryopump (yes/no): no

Vessel temperature: 60/60/60 overnight

------------------------------
ECDC Parameters
------------------------------
gas and pressure: D2 at 2e-4 Torr
sweep: 44/45/103 cm
scan: 20/120 s
______________________________________

During the run, we are likely to want to change the A-coil configuration at least once.

See SL_PLAN entry for details of the run plan.



Session Leader Summaries
Entered: Aug 7 2009 06:38:32:633PM
Author: Steve Wolfe
Run summary for Friday, August 7, 2009
MP#555 PF Error Field Evaluation and Compensation
SL: wolfe
PO: Marmar
EO: Parkin, Byford, Fitzgerald

The goal was to evaluate the possible changes to the error field
compensation feedback implied by the analysis of the single coil
tests performed on 1090702 versus the old prescription, based on 
the results of similar tests performed 1030717 ("r3d" model).
Two candidates were tested ("333" model and "888" model), based on
different truncations of the SVD fitting of the 1090702 data, as 
described in my logbook entries for that run made earlier this week.
We successfully completed most of the run plan, and conclude that
the original compensation algorithm is still the best of those tested. 
We also discovered a long-standing bug in the B21_PROJ routine which
leads to a negligible (< 10%) error in the original configuration but was 
causing a significant error in the testing of the "888" model. 

The first part of the experiment confirmed that the intrinsic locking
threshold density is very similar to the 2003 value for 1MA LSN
plasmas, namely nebar~1.2e20/m^3. This result was inconsistent with one 
of the new models, which predicted a lower threshold density, but 
consistent with the other which predicted error field of similar magnitude
but different orientation, as well as different sources, i.e. contributions
from different PF coils.  

The results of the active tests were that the original feedback prescription
is superior to either of the newer candidates for standard 1MA plasmas,
based on the minimum achievable density. We did not manage to test the
compensation to as low densities as have been run in the past at 1MA, 
and so could not determine whether some modification would be indicated.
We did succeed in avoiding locked modes down to nebar~8e19/m^3 (shot#8)
with the original programming, and later down to nebar~6e19/m^3 with the 
same programming but targeting a B21_PROJ=+.0001T. These bounds were not
set by appearance of locked modes but by our inability to get the density
down to lower levels. The tests using compensation based on the other models
resulted in locked modes at higher densities. In the case of the "333" 
model the feedback did not turn on the a-coil and we essentially hit the
intrinsic threshold. The other algorithm using the +Bbot +Dtop -Gbot -Jtop
a-coil configuration gave substantial a-coil demand and resulted in 
locked modes with fields that the "888" model predicted to be < 1G.

Raising the current to 1.2MA did result in a locked mode with the 
old compensation algorithm (Shot#27), at the rather high density of 
nebar~8.5e19/m^3 and an inferred |b21|~1G based on the r3d model. This 
locked mode appeared around 0.55sec, just into flattop. A variation (Shot#29)
of the compensation to target a projected b21=+.0002T, i.e. higher A-coil 
current, resulted in no locked mode, although the shot died from an injection
at .86sec; the density at 0.55sec was similar to #27, but then came 
back up to 1.0e20/m^3 for the remainder of the flattop. This may or may
not represent an improvement. Some modification to the model predictor
may be indicated, but it is not yet clear which terms should be modified. 

In the course of testing the "888" model, which required changing the
a-coil configuration to +Bbot +Dtop -Gbot -Jtop, which has a toroidal
phase of 76degrees, we discovered a bug in the B21_PROJ algorithm.
The error was forming the predictor using a weight for the acoil current 
accounting for only the real_part (cosine component) of the acoil field,
which is amounts to a factor of .93 for the normal 21 degree orientation,
but is a factor of four down at 76 degrees, causing the feedback to 
drive the acoil to very high currents and over-compensate the predicted
error. It took me an hour delay to figure out what was happening, 
and we corrected it by manually editing the B21_PROJ predictor (shot#17)
to use the approximately correct weight 3e-7 for the acoil current.
I have now modified the nonaxi_smw procedure, but not yet uploaded it
to CVS or downloaded the revision to the live directory. I'll take 
care of that before the next run, but since it makes a negligible 
contribution in the standard configuration, it shouldn't be necessary
to re-call the predictor for this reason. 


Physics Operator Summaries
Entered: Aug 7 2009 05:29:38:673PM
Author: Earl Marmar
The machine ran well today. Most shots had 1 MA disruptions, and the last 2 plasmas (27 and 29) were 1.2 MA disruptions. In spite of this we had only 1 fizzle. Early hards were a problem from time to time through the day.

There were many changes to the a-coil programming, which was the point of the miniproposal; physops need to be aware of this if they plan to import any of these shots for future use.

There was one shot lost to alternator vibration during check, and one to no gas (no high voltage during pulse).

There was one small delay due to data acquisition, and a couple of delays due to apparent high temperature readings on EF3L (most likely due to the Ross relays).

OH coaxes behaved well.

Scorecard:

Shot,Duration(s),Ipmax(MA),Result Shot,Duration(s),Ipmax,Result
| 01 0.159 0.553 Plasma | 02 1.627 1.004 Plasma |
| 03 1.604 1.003 Plasma | 04 1.540 1.040 Plasma |
| 05 1.988 1.009 Plasma | 06 1.999 1.012 Plasma |
| 07 0.000 0.003 Dud | 08 1.576 1.012 Plasma |
| 09 0.324 0.805 Plasma | 10 0.665 1.090 Plasma |
| 11 0.610 1.006 Plasma | 12 0.686 1.063 Plasma |
| 13 0.727 1.081 Plasma | 14 1.175 1.056 Plasma |
| 15 0.484 0.998 Plasma | 16 0.747 1.046 Plasma |
| 17 0.754 1.057 Plasma | 18 0.803 1.025 Plasma |
| 19 1.173 1.083 Plasma | 20 0.971 1.082 Plasma |
| 21 1.324 1.039 Plasma | 22 0.314 0.800 Plasma |
| 23 0.890 1.037 Plasma | 24 0.000 0.048 Dud |
| 25 1.564 1.012 Plasma | 26 0.791 1.055 Plasma |
| 27 0.716 1.304 Plasma | 28 0.120 0.055 Fizzle |
| 29 0.876 1.271 Plasma
Date 1090807: 29 shots. 26 plasmas. 1 fizzles. 2 duds. 0 System Error.
(Plasma = Ip gt 60.0 kA Dud = H_alpha lt 0.40 V)
Total plasma duration: 26.21 s (exceeding -55 kA)



Session Leader Comments
Aug 7 2009 09:02:18:497AM1090807001Steve Wolfe
Shot#1: Intrinsic threshold determination
very short runaway disruption.

Aug 7 2009 09:23:23:123AM1090807002Steve Wolfe
Shot#2: Intrinsic threshold determination
plasma into rampdown, density doesn't drop very far
Locked mode in rampdown at 1.56sec, nebar=1.4e20 (nl04=7.5e19)
Nebar only gets down to ~1.5 in flattop.

Next: increase clearin 2mm, let the walls unload to try to get
more density drop in flattop. 

Aug 7 2009 09:34:05:163AM1090807003Steve Wolfe
Shot#3: Intrinsic threshold determination
 increase clearin 2mm, let the walls unload to try to get
more density drop in flattop. 
Very similar, runaways down, still not much density drop. 
locks at 1.52sec, 1.36e20/m^3

Next: drop initial density to 8e19

Aug 7 2009 09:50:15:550AM1090807004Steve Wolfe
Shot#4: Intrinsic threshold determination
  drop initial density to 8e19, since threshold is below that.
Locked mode at 1.28sec, 1.2e20/m^3, in the expected nominal range.
Clear signatures on C-H LM loop diff and bp26de-jk at 1.25sec 
Nominal error field is 5.4G, Model 333 gives 1.6G, Model 888 gives 5.1G

I think this probably rules out the 333 model, but we'll proceed
to test anyway.

Next: step 2, turn a-coils back on, normal settings, standard taps.

Aug 7 2009 09:59:18:163AM1090807005Steve Wolfe
Shot#5:test 2003 feedback compensation algorithm. 
plasma full length, hards to 2e13.
density never gets below nl04=7e19 
oscillation on halpha after 0.7, ece sawteeth change period, but no 
obvious locked mode. 
Old model says |b21|< 1G, model333 claims overcompensated up to 4G,
Model888 says up to 6G. This is looking like the original model is
doing better than either of the new ones. 

Need to get the density down. Drop the initial density to 6e19. 

Aug 7 2009 10:10:59:800AM1090807006Steve Wolfe
Shot#6:test 2003 feedback compensation algorithm. 
 Drop the initial density to 6e19.
plasma full length
density at 6e19 but doesn't drop during the pulse.
No locked mode. Need to drop density; where's the cryopump?


Aug 7 2009 10:23:30:653AM1090807007Steve Wolfe
Shot#7:test 2003 feedback compensation algorithm. 
 Drop the initial density to 5e19.
Alternator alarm inhibit. No power shot.


Aug 7 2009 10:57:40:727AM1090807008Steve Wolfe
Shot#8:test 2003 feedback compensation algorithm. 
 Drop the initial density to 5e19.
disrupts at 1.57sec,
injection at 1.15sec.
No locked mode, density gets down to 8e19, then comes back up to 1e20m^-3
Having trouble getting down far enough to see anything; maybe should have
ecdc'd in He. 

Next: try again, lower target


Aug 7 2009 11:12:14:970AM1090807009Steve Wolfe
Shot#9:test 2003 feedback compensation algorithm. 
 Drop the initial density to 3e19.
early disruption, early hards 8e13
looks like an injection. 

Try again.

Aug 7 2009 11:26:25:937AM1090807010Steve Wolfe
Shot#10:test 2003 feedback compensation algorithm. 
 initial density to 3e19.
Lots of runaways disrupts at .668sec
possible locked mode between 0.4 and 0.45sec, looks like it stays
locked; may actually start before 0.4sec. Magnetics signature
at 0.380, nebar~6e19/m^3. Not a good data point, since we're 
not up to current yet and it's got lots of runaways. 

Try for one at nl04=4e19, then move on.

Aug 7 2009 11:37:26:273AM1090807011Steve Wolfe
Shot#11:test 2003 feedback compensation algorithm. 
Try for one at nl04=4e19
disrupts at 0.6sec, hards way down
No locked mode, maybe something at 0.4sec that goes away

Move on to step 3 without finding the minimum density with the
old model. See if the 1090702333 model does worse.


Aug 7 2009 11:52:55:597AM1090807012Steve Wolfe
Shot#12: Test 1090702333 model feedback compensation
Try for one at nl04=4e19, reduced P to 4 on NL04. 
disrupts at .68sec
Locked mode at .39 to 0.4sec, similar to shot#10
Got no acoil current this early, so it's not really a valid test
The 333 model is claiming the phase is ~110deg, so no demand in this 
direction (demand is negative). 

Next: raise nl04 to 5e19, change D gain




Aug 7 2009 12:05:06:310PM1090807013Steve Wolfe
Shot#13: Test 1090702333 model feedback compensation
Try for one at nl04=5e19, raise D gain to 5 on nl04
More runaways, got to .7sec, ran at 4e19
Locked mode at 0.56  or so, but no acoil demand (still negative).
nebar=6e19/m^3. 

Next: back to original B21_PROJ feedback, see if it will run 
at this density, which is lower than #8, without locking. 




Aug 7 2009 12:22:38:057PM1090807014Steve Wolfe
Shot#14: back to original B21_PROJ feedback, see if it will run 
at nebar~6e19, which is lower than #8, without locking. 

plasma to ~1.2sec, nl04=4.7e19
There is an injection followed by a possible locked mode right
at the end, 1.13sec on the injection. 
Through 1.1sec I can set a bound of nebar>8e19 for the locking density.
According to the old model |b21| < 0.5G, 
according to 1090702888 model |b21| ~ 5G@-22deg

Go ahead and change the acoils to +BBOT +DTOP -GBOT -JTOP,
and change B21_PROJ feedback to 1090702888 model.





Aug 7 2009 12:55:59:287PM1090807015Steve Wolfe
Shot#15: Move on to step #4, "BBOT +DTOP -GBOT -JTOP" 
change B21_PROJ to use 1090702888 model. 
Same density program.

plasma to .45sec, acoil is on, not a locked mode. 
Injection kills it. 
The applied field is 8G, which I don't understand. 
The b21_proj claims it's got an error signal of < 1G, 
but the total field is 6G at 78 degrees, i.e. at the applied field angle.
This implies that the intrinsic error is nearly ortho, but it's at
-118deg, although it is over around -180 earlier in the shot. 
The B21_PROJ gain and the acoil enable both come on at 0.2sec,
when the model claims the angle is -170degrees, which is in fact
almost perp to the applied angle. That won't work.

Delay P and I gains to 0.4sec, when the angle is at -115deg, which 
is a little better aligned. 




Aug 7 2009 01:30:51:330PM1090807016Steve Wolfe
Shot#16: Move on to step #4, "BBOT +DTOP -GBOT -JTOP" 
change B21_PROJ turn on time from .2 to 0.4 sec. 
Same density program.
plasma to 0.7sec, lots of hards,
locked mode at ~0.62sec based on sawtooth change, but I don't see
any magnetic signature. Acoil is nearly full on, b21_proj error is
down below 1G again, but model-based total field is still high,
around 8G, although the intrinsic field is coming out around 3G
around -90deg. I'm doing something wrong!

Somehow the coefficient on the acoil seems to be wrong. 








Aug 7 2009 02:03:24:523PM1090807016Steve Wolfe
Shot#16: The problem is apparently with the Acoil coefficient
that's getting picked up from the 109070288 tree. It is coming
out as 7.47e-8 and it should be around 3e-7. I think it was 
probably created with the wrong patch panel configuration.

Yes, the patch panel settings are taken from the engineering
tree, and the value in engineering_1090702888 for \ENGINEERING::TOP.POWER_SYSTEM.CORRECT_COIL:PATCH_PANEL:CONNECTIONS
is [0.,0.,1.,-1.,0.,0.,-1.,1.] instead of 
[ 0.00000,      1.00000,      1.00000 ,     0.00000 ,     0.00000     -1.00000,     -1.00000      0.00000

No, I changed it and it didn't help; still getting a 7.47e-8. 
I think there's a bug in B21_proj. It's taking real_part
of acoil_coef instead of abs(acoil_coef). That made a negligible 
error in the 21 deg case, but it's big for this version. 

Need to edit the nonaxi_smw routine. 
Not sure what the routine is doing is correct. 
Try manually editing the acoil coefficient to 3e-7 and run it again 







Aug 7 2009 02:17:25:323PM1090807018Steve Wolfe
Shot#17: Retry with the 888 model, but with the coefficient on the
acoil set to 3e-7 manually. I think the b21_proj algorithm has a bug. 

plasma to .75, locked mode at around .56 to .61sec, nebar=6.5e19
Now the model net field is under 1G, as it should be. 
The net field according to the old model is around 3G, 
which may make sense at this density as a locking threshold.

Move the start time back to 0.2sec, to give it a fair
comparison. It seems pretty clear that this compensation is not 
as good as the old one, although I'm still not sure the algorithm 
is correct. 







Aug 7 2009 02:25:54:820PM1090807018Steve Wolfe
Shot#18: Testing 1090702888 model, with corrected (?) coefficient
Start feedback at 0.2sec, programmed nl04=5e19. 

Still disrupts at 0.8sec
Locks at .63sec, magnetic signatures on C-K and H-K, and on bp26_de-jk
888 model says total b21 is ~1G, old model says 3G. 
nebar=7.6e19. 

Next: raise nl04 program to 6e19





Aug 7 2009 02:40:01:713PM1090807019Steve Wolfe
Shot#19: Testing 1090702888 model, with corrected (?) coefficient
Raise nl04 to 6e19, see if it will run clean. 

plasma to 1.16sec, locked mode at 0.83sec, nebar=8.9e19/m^3 
model888 b21 is < 1G, old model b21=3.5G

This model also fails. 
Next: target b21_PROJ to -.0001T (step 5 for this model).  


Aug 7 2009 02:54:37:540PM1090807020Steve Wolfe
Shot#20: Testing variation on the 1090702888 model, 
with corrected (?) coefficient. Target to -.0001T
  
plasma to 1sec, injection at .4sec, locked mode at .55sec,
but may be influenced by earlier injection.
nebar=9.5e19, b21(888)=1.2G, b21(r3d)=3G : this doesn't fit either way,
repeat and see if injection disappears.


Aug 7 2009 03:14:14:100PM1090807021Steve Wolfe
Shot#21: Testing variation on the 1090702888 model, 
with corrected (?) coefficient. Target to -.0001T
  
plasma to 1.3sec, still lots of runaways
locks at 0.78sec, has an injection at 0.75sec. 
I think the injection causees the lock, but move on with
the opposite variation anyway.
nebar=9.7e19, b21(r3d)=3.3G, b21(888)=1.1G

Next: target to +.0001T

Aug 7 2009 03:24:18:467PM1090807022Steve Wolfe
Shot#22: Testing variation on the 1090702888 model, 
with corrected (?) coefficient. Target to +.0001T
  
early disruption, 0.3sec, injection and runaways. 
No locked mode. 
Try one more time, then change taps back to +Dtop -Dbot -Jtop +Jbot


Aug 7 2009 03:41:58:403PM1090807023Steve Wolfe
Shot#23: Testing variation on the 1090702888 model, 
with corrected (?) coefficient. Target to +.0001T
  
plasma to .9sec, locks around .85sec
nebar=9e19, b21(r3d)=4G, b21(888)=1.3G

Next: back to standard taps, standard feedback control,
leave target at 0.0001. Use the keyword for ACOIL,
since the EO hasn't updated the engineering tree yet.



Aug 7 2009 04:03:35:153PM1090807024Steve Wolfe
Shot#24: Testing variation on the original (r3d) model, 
including the bug that's been there since 2003. It makes 
a little less than 10% difference in this configuration. 
target=+.0001 

No gas. PLC glitch, no HV enable.


Aug 7 2009 04:19:22:180PM1090807025Steve Wolfe
Shot#25: Testing variation on the original (r3d) model, 
including the bug that's been there since 2003. It makes 
a little less than 10% difference in this configuration. 
target=+.0001 

plasma to 1.55sec
No locked mode, nebar down to 5.7e19 by eof
b21(r3d)=1.5G, b21(888)=7G, b21(333)=5.3G. 

next: -.0001 target


Aug 7 2009 04:32:31:207PM1090807026Steve Wolfe
Shot#26: Testing variation on the original (r3d) model, 
including the bug that's been there since 2003. It makes 
a little less than 10% difference in this configuration. 
target=-.0001 

plasma to .75sec, short-lived locked mode at 0.65sec, nebar=1e20
injections starting at .6sec could be implicated. 

Move on to step 6: 1.2MA, target back to zero. 

Aug 7 2009 04:45:59:577PM1090807027Steve Wolfe
Shot#27:  step 6: 1.2MA, target back to zero.
plasma to 0.7sec, locks between 0.5 and 0.55sec
nebar~8.5e19, b21(r3d)=1G. 

Aug 7 2009 04:49:04:300PM1090807027Steve Wolfe
Shot#27:  step 6: 1.2MA, target back to zero.
plasma to 0.7sec, locks between 0.5 and 0.55sec
nebar~8.5e19, b21(r3d)=1G. 

next: B21_PROJ target to +.0002

Aug 7 2009 05:11:12:580PM1090807029Steve Wolfe
Shot#29:  1.2MA, B21_PROJ target to +.0002
plasma to 0.86sec, nebar=1e20, no locked mode. 
b21(r3d)=2.5G, @35deg. Is this better than 27 or was that just random?
This one has a big injection at .85sec. 

END OF RUN

Physics Operator Comments
Aug 7 2009 09:08:07:423AM1090807001Earl Marmarstart from 1090807032
nl_04 target to 1e20, then negative after 0.7 seconds
increase nl_04 prop gain to 8 (from 2)
extend nl_04 derivative gain to end of shot
plc disable A-coils
enable argon puff (PG1); program 50 ms @100, starting at 0.3 seconds

bouncy startup, runaways, dies at 550 kA

baseline offset f25, 1.2e-2
Aug 7 2009 09:34:28:147AM1090807002Earl Marmarprefill puff to 26 ms (from 24 ms)

plasma
disrupts in rampdown
still a bit of a bounce in startup
Aug 7 2009 09:34:55:897AM1090807003Earl Marmarincrease clearin to +0.001 (from -0.001)

plasma
same rampdown disruption
Aug 7 2009 09:46:39:780AM1090807004Earl Marmarnl_04 target to 8e19 (from 1e20)
plasma
disrupt at end of flattop
Aug 7 2009 09:57:50:023AM1090807005Earl Marmarprefill puff (deuterium) to 27 ms (from 26 ms)
plc enable A-coils

plasma
ramps all the way down
Aug 7 2009 10:11:54:910AM1090807006Earl Marmarnl_04 target to 0.6e20 (from 0.8e20)
plasma
early hards are up, but suppressed at about .1 s
ramps all the way down
Aug 7 2009 10:42:30:667AM1090807007Earl Marmarprefill puff to 28 ms (from 27 ms)
nl_04 target to 0.5e20 (from 0.6e20)

alternator alarm during check; no power shot
Aug 7 2009 10:56:32:897AM1090807008Earl Marmardelays before this shot for alternator and then data system

no dpcs changes

plasma
early hards
disrupts just after end of flattop
Aug 7 2009 11:09:35:127AM1090807009Earl Marmarnl_04 target to 3e19 (from 5e19)

plasma
disrupt just after .3 s, preceded by a large impurity injection
hards in the mid to high 10^13's
Aug 7 2009 11:24:22:717AM1090807010Earl Marmarprefill puff to 31 ms (from 28 ms)
plasma
plenty of hards
disrupts in flattop, 0.66s
Aug 7 2009 11:43:36:950AM1090807011Earl Marmarprefill puff to 34 ms (from 31 ms)

nl_04 target to 4e19 (from 3e19)

plasma
hards much reduced (low 10^12's)
disrupts at .6 s, preceded by injection
Aug 7 2009 11:51:13:703AM1090807012Earl Marmarnl_04 prop gain to 4 (from 8)

moving to step 3 in the run plan
B21_PROJ keywords: SHOT=1090702333,ACOIL="+DTOP -DBOT -JTOP +JBOT"; target waveform still 0

plasma
early hards ok, rising after 0.5 s
disrupt in flattop, 0.68s
Aug 7 2009 12:05:11:310PM1090807013Earl Marmarnl_04 deriv gain to 5 (from 3)
nl_04 target to 5e19 (from 4e19)

plasma
disrupt at 0.72 s
Aug 7 2009 12:14:46:347PM1090807014Earl MarmarB21_PROJ back to earlier configuration (keywords left blank)

plasma
disrupt at 1.17 s, preceded by impurity influx
hards ~1e12 for most of the shot, rising just before the end

Aug 7 2009 12:50:52:920PM1090807015Earl Marmarmoving to step 4 in the run plan
A-coil taps changed to:
+Bbot +Dtop -Gbot -Jtop

B21_PROJ feedback keywords to:
SHOT=1090702888,ACOIL="+BBOT +DTOP -GBOT -JTOP"

plasma
disrupt at 0.48 s, preceded by increase in radiated power

Aug 7 2009 01:06:46:543PM1090807016Earl MarmarB21_PROJ prop and integ gain turn-on moved to .4 s (from .2 s)

plasma
disrupt at .74 s, not preceded by any obvious impurity problem

Aug 7 2009 02:10:24:593PM1090807017Earl Marmardelay before this shot while session leader considers the results and path forward

Edit B21_PROJ, correct_coil:bus_r_cur to 3.0e-7

plasma
disrupt at 0.75 s

Aug 7 2009 02:24:24:487PM1090807018Earl MarmarB21_PROJ prop and integ gain on at 0.2 s

plasma
disrupt at 0.8 s

Aug 7 2009 02:59:10:730PM1090807019Earl Marmarnl_04 target to 6e19

plasma
early hards up
disrupt at 1.17 s

Aug 7 2009 02:58:51:650PM1090807020Earl Marmarmoving to step 5

no change in a-coil patch panel

B21-PROJ target to -0.0001 T, from 0.1 s through 2.0 s

4 minutes in init because of data system hang

plasma
early hards similar to shot 19
disrupt at 0.97 s

Aug 7 2009 03:12:25:897PM1090807021Earl Marmarno changes

plasma

disrupt at 1.32 s
Aug 7 2009 03:23:13:887PM1090807022Earl MarmarB21_PROJ target to +.0001, from 0.1 s through 2.0 s

plasma
disrupt at .31 s
Aug 7 2009 03:38:00:557PM1090807023Earl Marmarno changes

plasma
disrupt at 0.89 s

Aug 7 2009 04:03:42:233PM1090807024Earl Marmarreturn the a-coil configuration to the "standard" settings +Dtop -Dbot -Jtop +Jbot

prefill puff to 35 ms (from 34)
B21_PROJ keyword ACOIL="+DTOP -DBOT -JTOP +JBOT"
leave the B21_PROJ target at +0.0001 T

dud; no gas

Aug 7 2009 04:19:41:963PM1090807025Earl Marmarno dpcs changes

plasma
disrupt at 1.56 s

Aug 7 2009 04:35:38:663PM1090807026Earl MarmarB21_PROJ target to -0.0001 T

plasma
disrupt at 0.79 s

Aug 7 2009 04:50:48:550PM1090807027Earl MarmarB21_PROJ target to 0
Ip to -1.2 MA

plasma
disrupt at 0.71 s

Aug 7 2009 04:56:02:180PM1090807028Earl MarmarB21_PROJ target to +0.0002 T

fizzle, almost no plasma current


Aug 7 2009 05:11:04:440PM1090807029Earl Marmarprefill puff to 33 ms (from 35 ms)

plasma
disrupts at 0.87 s
no hards

Engineering Operator Comments
ShotTimeTypeStatusComment
108:59:57:590AMPlasmaOk
209:12:33:567AMPlasmaOk
309:25:20:420AMPlasmaOk
409:38:07:523AMPlasmaOk
509:50:55:097AMPlasmaOk
610:03:42:123AMPlasmaOk
710:20:56:010AMPlasmaOk
810:49:25:203AMPlasmaOk
911:04:09:717AMPlasmaOk
1011:16:59:133AMPlasmaOk
1111:29:41:673AMPlasmaOk
1211:42:34:947AMPlasmaOk
1311:55:19:693AMPlasmaOk
1412:07:58:950PMPlasmaOk
1512:35:02:473PMPlasmaOk
1612:57:39:507PMPlasmaOk
1702:04:32:417PMPlasmaOk
1802:17:09:610PMPlasmaOk
1902:29:42:700PMPlasmaOk
2002:42:24:793PMPlasmaOk
2103:06:20:343PMPlasmaOk
2203:18:53:620PMPlasmaOk
2303:31:25:020PMPlasmaOk
2404:00:10:540PMPlasmaOk
2504:12:43:630PMPlasmaOk
2604:25:14:717PMPlasmaOk
2704:37:47:383PMPlasmaOk
2804:50:35:423PMPlasmaOk
2905:03:06:247PMPlasmaOk

System Availability
Aug 7 2009 08:59:32:040AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (diode+foil), AXA, AXJ, WB3AX, WB4AX, LEDGE-AX working fine. MID/LEDGE/DIV foils still need calibrations appliedJul 28 2009 09:59AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoBottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel AccessMay 30 2008 02:25PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoCyopump hardware is not yet reinstalled in the cell.Jul 14 2009 09:21PM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationnosafely disabled; ready to be dismantledMay 28 2008 10:22AM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnopower locked & tagged out; gate valve disabledMay 28 2008 10:03AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCno6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel ActivityJun 10 2009 02:35PM (dekow)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesThe lower freq. 16 channels are ready. Still need calibration and signal level adjustmentsJul 14 2009 12:15PM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Problem with controller - signal noisy.Jul 14 2009 09:11PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATnoDisconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work.Jun 04 2008 12:24PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesoperational at 80 MHzJul 21 2009 04:49PM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesantenna and FFT operationalJul 21 2009 04:49PM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesavailable for conditioning and testingJul 21 2009 04:50PM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data but processed data not in tree. WB1-LY not attached.Jul 07 2009 01:01PM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesCollecting spectra but control system problem is not reporting voltages to treeJul 28 2009 10:00AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Recalibrated 7/27/09.Jul 28 2009 04:22PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesOperational --- Uncalibrated and needs to be positioned at portJun 25 2009 05:08PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesSystem is operable. Channels 7 and 9 (of 32) are dead.Aug 05 2009 02:48PM (edlund)Miklos PorkolabPhase Contrast Imagingarai,edlund,ennever,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyesOperational ---- ECDC running as required Jun 19 2009 08:06AM (irby)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesAs of 7/21/09, all channels are operational (50, 60, 75, 88, 88usb, 88lsb, 110, 140 and 110-140 swept frequency)Aug 04 2009 11:20AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasmaJun 18 2009 01:01PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes2 lasers working. 15 spatial channels operational. Initial (NOT final) Te calibration applied. ***No ne calibration yet*** Aug 05 2009 08:44AM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgeyesOperational, but ***uncalibrated***Aug 05 2009 12:13PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyescables attached, DAQ test run, ready for first plasmaJun 17 2009 03:42PM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke