Alcator C-Mod Run 1091016 Information

Back to runs

Miniproposals
Miniproposal:579
Date Filed: 9/3/2009
Title:Characterization and optimization of I-mode
First Author:Dennis Whyte
Session Leader:Dennis Whyte (shots 1-34)

Operators
Session leader(s):Dennis Whyte
Physics operator(s):Steve Wolfe
Engineering operator(s):Andy Pfeiffer,Bill Parkin,Ed Fitzgerald

Engineering Operator Run Comment
automatically entered by signon - please replace with real comment

Session Leader Plans
Entered: Oct 16 2009 08:24:29:530AM
Author: Dennis Whyte
Characterization and Optimization of I-mode
----------------------------------

Day 2.5

The purpose of these experiments is to characterize the necessary parameters to obtain I-mode (a.k.a. enhanced L-mode) while documenting I-mode plasma characteristics and optimizing I-mode towards its application in Alcator C-Mod for high confinement at low density. The experiment will focus on expanding the available I-mode operating space by exploring the effects of shaping, density, q95, and Ip with a goal of obtaining basic scaling relationships for further use on C-Mod and possible exploration on other devices.


Reference shot:
We realized after Day 2 (which was actually a very short
day due to alternator problems) that we
had not obtained exact shaping we wanted, so
Wolfe will re-develop this shape to desired
quantities... mostly focussed on getting
matched q95 to 2008 shots)

Cryopump ON
Toroidal Field: 5.0 - 5.8 T (clockwise)
Plasma Current: 0.8 - 1.4 MA
Working Gas Species: D2
Density: Target NL04 densities from 0.3 to 1 (1e20)
Boronization Requested: NO
ICRF Power: > 5 MW, Each shot will have 4 steps in RF of 200 ms each.

Diagnostics:
ECE with varying B field
Edge TS with alignment for pedestal/edge as reference shot
Note: DNB is offline so no pedestal diagnosis available from CXRS

Run Plan
--------

Our second day only garnered a completion of step 3.

The analysis to date suggested that q95 was the most
important parameter in H-mode avoidance which may affect our
choices in the scans. However this can be confused with
shape dependencies too.

We'll start today with a focus on tweaking the shape
to better match 2008 shots and lower q95 at 1.35 MA
+ work on earlier density control for the density scans
of steps 4 and 5.


- RF power will ramp up to the first step rather than
turn on to full power immediately.



4. Density scan at high Ip / low q95
N.B. ordering of density scan is reversed from MP
Reference shape: #1080416015, Ip = 1.35 MA, Bt = 5.63 T 6 shots
a) NL04 = 0.5e20, Prf steps: 4.3, 4.6, 4.9, 5.2 (or lowest density achievable)
b) NL04 = 0.6e20, Prf steps: 4.3, 4.6, 4.9, 5.2
c) NL04 = 0.7e20, Prf steps: 4.3, 4.6, 4.9, 5.2
d) NL04 = 0.8e20, Prf steps: 4.3, 4.6, 4.9, 5.2
e) NL04 = 0.9e20, Prf steps: 4.3, 4.6, 4.9, 5.2
f) NL04 = 1.0e20, Prf steps: 4.3, 4.6, 4.9, 5.2


5. Density scan at low Ip / high q95 (3b forms part of scan)
Reference shape: #1080416015, Ip = 1.0 MA, Bt = 5.63 T 6 shots
a) NL04 = 0.3e20, Prf steps: 3.1, 3.2, 3.3, 3.4 (or lowest density achievable)
b) NL04 = 0.4e20, Prf steps: 3.1, 3.2, 3.3, 3.4
c) NL04 = 0.5e20, Prf steps: 3.1, 3.2, 3.3, 3.4
d) NL04 = 0.6e20, Prf steps: 3.1, 3.2, 3.3, 3.4
e) NL04 = 0.7e20, Prf steps: 3.1, 3.2, 3.3, 3.4
f) NL04 = 1e20, Prf steps: 3.1, 3.2, 3.3, 3.4


When we get through this we move the "shaping study"

6. Increase κ to ~1.7, same triangularity ~ 0.6 as Day 1 (Circle 2 Fig. 3) 3 shots
a) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.8e20, Prf steps: 3.1, 3.2, 3.3, 3.4
b) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.5e20 (or lowest possible) , Prf steps: 3.1, 3.2, 3.3, 3.4
c) Ip = 1.35 MA, Bt = 5.63 T, q95 ~ 2.9, NL04 = 0.8e20, Prf steps: 4.3, 4.6, 4.9, 5.2


7. Increase κ to ~1.8 (or max.), same triangularity ~ 0.6 as Day 1 (Circle 3 Fig. 3) 3 shots
a) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.8e20, Prf steps: 3.1, 3.2, 3.3, 3.4
b) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.5e20 (or lowest possible) , Prf steps: 3.1, 3.2, 3.3, 3.4
c) Ip = 1.35 MA, Bt = 5.63 T, q95 ~ 2.9, NL04 = 0.8e20, Prf steps: 4.3, 4.6, 4.9, 5.2

8. Keep κ at ~1.8 (or max.), increase triangularity to 0.8 (Circle 4 Fig. 3) 3 shots
a) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.8e20, Prf steps: 3.1, 3.2, 3.3, 3.4
b) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.5e20 (or lowest possible) , Prf steps: 3.1, 3.2, 3.3, 3.4
c) Ip = 1.35 MA, Bt = 5.63 T, q95 ~ 2.9, NL04 = 0.8e20, Prf steps: 4.3, 4.6, 4.9, 5.2

9. Reduce κ to ~1.7 (or max.), keep triangularity at 0.8 (Circle 5 Fig. 3) 3 shots
a) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.8e20, Prf steps: 3.1, 3.2, 3.3, 3.4
b) Ip = 1 MA, Bt = 5.63 T, q95 ~ 3.9, NL04 = 0.5e20 (or lowest possible) , Prf steps: 3.1, 3.2, 3.3, 3.4
c) Ip = 1.35 MA, Bt = 5.63 T, q95 ~ 2.9, NL04 = 0.8e20, Prf steps: 4.3, 4.6, 4.9, 5.2

10. Steady demonstration shot Type #1: �??ITER q=3�?? 4 shots
Bt=5.4 T, q95~3, shape: TBD
Variables (influenced on parameter scan results of 2-4.
- target density: NL04 ~ 0.5-0.7 to reduce pedestal collisionality to ITER target 0.08
- RF: constant through shot, ~ 4.5 - 5 MW

11. Steady demonstration shot Type #2: Low collisionality AT / LH target 4 shots
Bt= TBD, q95~4, shape: TBD
Variables (influenced on parameter scan results of 2-4.
- target density: minimum possible NL04 ~ 0.5-0.7
- RF: constant through shot, ~ 3.5 - 4 MW



Physics Operators Plans
Entered: Oct 15 2009 02:38:55:203PM
Author: Steve Wolfe
Physop plan and engineering setup for Friday, Oct 16, 2009
MP#579 "Characterization and optimization of I-mode"
SL: Whyte
PO: wolfe

-----------------
Engineering Setup
-----------------
Overnight 60C bake and ECDC in helium:
------------------------------
ECDC Parameters
------------------------------
gas and pressure: He at 5e-5 Torr
sweep: 44/45/103 cm
scan: 20/120 s

Run begins at 09:00 and ends at 17:00
NOTE: A boronization has been scheduled for Friday night,
after the completion of the run. Therefore we will remain
in CONTROLLED ACCESS from 17:00 to about 18:00, and the
cell and power room will then be closed for boronization until
Saturday morning.


Power systems as on: 1091009013

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gatevalves and shutters: ECE, VUV, Z-bolo, HIREX_SR

Torvac gatevalve toggle (yes/no): No

Boronization(yes/no): no
Overnight ECDC (yes/no): YES
ICRF(yes/no): yes (all transmitters)
LH(yes/no): no
DNB(yes/no): no
Cryopump (yes/no): YES (all shots)

Vessel temperature: 35/35/35

--------------------------------------------------
Physop plan:

Start from 1091009013 (1.35MA, 5.6T, 8e19 program) and
modify ZCUR from -.005 to +.001 to reduce kappa from 1.7 to 1.64,
perhaps with some adjustment to prevent the density dip
between .38 and .55sec (try diverting earlier), and reduce
the flattop nl04 to 5e19 to start the density scan of part 4
of the MP. We may need to repeat the 8e20 point from the reference shot,
which was step 3e but also part of the density scan. I expect locked
mode problems at the lower densities in this scan; up to SL how long
we take trying to get rid of these, but it may be worth one shot to
try tweaking the B21_PROJ observer to give more A-coil current and see
if it helps. The scan is supposed to cover 0.5 to 1.3e20 at 1.35MA .

Continuing the run plan, step 5 goes back to 1.0MA, and carries out
a density scan from 0.3 to 1.0e20, with similar rf waveforms with itty-bitty
steps at each density. May need to adjust zcur to preserve elongation.
We'll attempt this going from low to high density,
although we may pick up some of the intermediate points first by accident,
since we'll be starting from the high density end-point of scan 4.

Step 6 is the "shaping study", which should be a lot of fun. This will be
done first at 1MA, nl04=0.8e20, which is close to one of the scan 5 points,
but with elongation increased to 1.7. This is close to 1091009009
which was k=1.67. Some adjustment may need to be made to keep the lower triangularity fixed. The plan calls for two densities (0.8 and 0.5e20,
then a high current version (1.35MA) which is called out as q95=2.9;
however, since 1091009013
was at this current with kappa=1.699 and had q95=3.1, this may already be
done, or else we would need to reduce the kappa to get the lower q95. This
needs to be discussed with SL if we get this far.

Step 7 is the same as step 6 but at higher elongation, nominally 1.8 instead
of 1.7. It also calls out the same q95 for the same current and field,
which seems inconsistent unless he wants to decrease minor radius as
well as increase height. SL needs to clarify. We seem to have some headroom
on vertical stability on 1091009009 and 13, so 1.8 should be doable.

I don't expect to get past step 7, but if we do the rest of the run
plan is in the MP, and probably under SL_PLAN. The next step would be
increased triangularity.

-----------------------------------------
After the run, we will go to controlled access (keys required!)
until no later than 18:00, then close up for boronization until
Saturday morning.

We anticipate that if the run is successful we will reach
the neutron alert level (10^14 neutrons) during the day. Therefore,
any cell access would require use of the geiger counter survey
meter and wearing of film badges. If it is possible to delay
in-cell work until Saturday, that would be advisable.

Session Leader Summaries
Entered: Oct 16 2009 06:35:23:157PM
Author: Dennis Whyte
A very productive day.

Early shots we had to work through density control so that
we could avoid locked mode disruptions. Also tuned up ICRH

Started at 1.35 MA, q95~2.9
First good shot #9.
These were plagues with impurity injections during flattop.
One of the recipes to avoid this became sweeping
the strikepoint around, so indicating that we were getting
the upper divertor too toasty with stationary strikepoint
positions.

shot 13 was lowest density in Step 4 at q95~2.9 at NL04~0.75
but at this point we noted the plasmas were suffering
dithering into brief H-mode periods. Plus the impurity injection
were still plaguing us. Move the X-Point closer to the plate (#16) to
avoid putting heat onto bad places like upper corner and
cryo tiles. This "unsteady" aspect of the 1.35 MA shots
makes them difficult to assess. Interestingly, more power would
seem to get rid of the dithering (?) which we saw through the day.
At this point we went to 1.2 MA to avoid the delays from disruptivity
and hopefully get better density control

1.2 MA, q95~3.3
----------------

We performed a density scan here.

#25 and #26 are a great comparison. Our expectations about I-mode
getting really awesome at low density were not borne out. Note that 26
has lower density NL04~0.7 than NL04~0.9 in 25, yet 25 has higher Te_ped
and confinement! #25 also has higher radiated power at lower density?
Anyway I think this and the 1.35 MA experience is telling us
that I-mode doesn't necessarily like low density. Of course we
were also having impurity injection problems today.

Starting raising density (#28- 30) and the I-modes generally improved although
we were still bothered by the injections. Shot 28 seemd to hit
a "sweet spot" for density and we got past 1e14 n/s and a hot Te_ped

Getting sick of injections I decided to try using some neon in the shot
a la Reinke's experiments. This seemed to have quite a positive effect
#31 vs #30 on injections although our Ne puff was too large and
it hit down our performance. We backed off on the neon for shot 33 at
NL04=1.0. This produced our trophy shot with a beautifully clear
transition to I-mode and very constant W and neutrons > 1e14 n/s.

For the last shot we tried a 1.35 MA again (NL04=1.1) hoping
things would be cleaner with the neon (compare to 16).
This worked... we got again a clear transition to I-mode but
it was short lived due to an H-mode transition. Great data
correlating the transitions on edge ECE and reflectometers for
this shot.




Physics Operator Summaries
Entered: Oct 16 2009 06:02:58:833PM
Author: Steve Wolfe

Physop summary for Friday, Oct 16, 2009
MP#579 I-mode 
SL: Whyte
PO: wolfe
EO: Pfeiffer, Parkin, 

The initial 1.35MA part of the run was plagued by disruptions of various
sorts, including a lot that were just unexplained. We raised the density
fairly early and made some tweaks in feedforward and NL04 gains to try to 
get rid of dips and subsequent locked mode problems. I ended up with D=10,
P=5,and some pg3 feedforward, which seemed to give a reasonably stable
target. 

We made a lot of small shape changes, first to try to get the original SL
request, then adjustments to try to get rid of injections, which seemed to be
correlated with having strike point in the inner corner. These had the side
effect of moving q95 around in the range 3.1 > q95 > 2.8, and probably
resulted in some of the disruptions. 

There were only a few full length, or even most of flattop, shots at 1.35MA,
but some of these did have I-mode ELMs, and some were dithering on the edge of
H-mode. See SL summary for details. 

At shot#19 we punted the 1.35MA and dropped to 1.2MA (q~3.4) to try to do the
density scan there, intermediate between case 4 and 5 of the MP run plan. We
ran as low as 7e19 and as high as 1.2e20. Zeff was reading very high (like 4)
except at the highest densities, but performance wan't too bad, with L/I-mode
energies over 170kJ. We were still having problems with injections, some
leading to disruptions. On shot#23 I implemented an RXU sweep to try to reduce
the localized heat loads, with possibly favorable results. 

On shot#31 we started using neon puffing, initially 200msec@2psi, and this had
a strong benficial effect on the injections and on prad. This technique needs
to be explored further. We did two shots with 2psi and two at 1.1psi. 
Shot#33 was at 1.2MA, 1.0e20 and had a sustained I-mode over 180kJ and neutron
rate over 1e14/sec. The last shot, at 1.35MA, 1.1e20 (target) produced two
ELM-free H-modes over 230kJ and 1.7e14neut/sec. All of the neon-seeded shots
had low or no injections and controlled Prad in the L- and I-modes, although 
Prad ran up in H-modes, so we apparently would need a different neon
prescription for those. It seems surprising that the neon would last through
the pulse in the I-mode cases, since it should be pumped by the cryopump, but
the 200msec puff seemed to be sufficient. Shot#32, with 2psi, had an abrupt
change in Prad (down) at ~1.3sec corresponding to entry into I-mode; this
might be interpreted as a reduction in the neon radiation due to pumping, but
it seems too abrupt. 

I was fighting runaways for most of the day, but these finally went away
beginning with #31. I had increaed the pg4 puff from 50 to 52msec, which was
in the range that had not been successful in suppressing the runawsys earlier;
not clear why it seemed better on this shot; possibly related to higher target
densities without disruption in the preceding discharge. This was also the
first neon shot (which can't be causally related to the low runaways on 31) and
all the subsequent shots were also runaway-free.

In the end we deviated considerably from the run plan, but got a fair bit of
useful data on I-modes and H-mode thresholds in USN (which really look like
their are more hidden variables than places to hide), and at least one "trophy
I-mode shot" on #33. 

Scorecard:
       Tests/NoPower shots       0
       Duds                      0
       Fizzles                   6
       Plasmas                  28 (11 full length) 
       ===========              ==
       Shots                    34 

 

Session Leader Comments
Oct 16 2009 10:21:49:320AM1091016001Dennis WhyteStart today trying to get consistent shaping
for q95~2.9 with higher triangularity
+ work out early density control /w cyro so
that we get lower density at flattop, but no
early runaways and /or later locked modes at this higher Ip

Early disruption.
Oct 16 2009 10:22:09:147AM1091016002Dennis WhyteDisruption at 0.8 s

kappa: 1.66, upper delta ~ 0.67, q95 ~2.92

RF was happy up until this point.

Wolfe believes cause of disruption was injection.
Oct 16 2009 10:22:27:540AM1091016005Dennis WhyteDisruption at 0.8 s

kappa: 1.64, upper delta ~ 0.67, q95 ~2.85:" Good

Turned off RF on this shot
Disruption is not caused by injection
but probably locked mode. We are still getting
large swings in early density from difficulties
of the fuelling keeping up with the cryo.
Oct 16 2009 10:35:58:887AM1091016006Dennis WhyteFizzle
Oct 16 2009 10:49:32:813AM1091016007Dennis WhyteDisruption, but later.

It looks like our problem is locked modes due to transients
in the density. the early nl04 dip starts a mode that
we get through, but then when the density dips again
at higher Ip in flattop, it disrupts. This is supported
by the timing of the disruptions and MHD signals.
Oct 16 2009 11:07:56:100AM1091016008Dennis WhyteShot ran through.

Got 8e19 target density w/o locked modes.

RF matching wasn't great so power was jumping around

Missed ECE on this shot.

A lot of ELMs in this shot

H98 suffered: ~ 0.88

No H-mode transition.
Oct 16 2009 11:30:32:393AM1091016009Dennis WhyteBetter density control on this.

RF was more steady and got to Wth ~ 165 kJ and H98~0.95

No H-mode transition

Disrupted at 1.25 apparently due to an injection, which actually
started at 1.1 s.

next shot: reduce gap from 2 to 1.5 cm

Also tweak the strikepoints to outboard a bit. It appears
that we're having an issue with the ISP hitting into
the upper inner corner. The high-Z injection could be
from over-heating in that location... and at the
same time we need to avoid putting the outer strikepoint
on the discontinuous tiles at the cryo entrance!

Oct 16 2009 11:44:09:273AM1091016011Dennis WhyteFizzle
Oct 16 2009 12:14:43:127PM1091016012Dennis WhyteThis was getting to a nice I-mode (pedestal Te ~700 eV, H98 > 0.9
constant nl04~0.8, increased by RF to 0.9) but we
had another impurity injection.

We are still suspecting overheating in the upper divertor.
Next shot: move X-point higher to decrease the radial
distance of separation between the two strikepoints.



Oct 16 2009 12:19:14:503PM1091016013Dennis WhyteThe injections were smaller in this case but
perturbating. Nice density control.

we pulled the X-point a little higher on this shot.

the problem is that we are getting dithering H-modes with each sawtooth
crash in these shots and RF power ~3.8 MW. this makes the "I-Mode" very
transient. It looks like we're at
the lower density limit (NL04 = 0.8) at this plasma current / q95.
The H-mode is just too easy to access. Plus
we're battling the 1.35 MA disruptions which makes exploration
difficult.

So consider shot 13 lowest density step in Step 4.

q95=2.95, kappa=1.65, delta = 0.64

H quality not reliable since dW/dt was still large.




Oct 16 2009 12:40:09:513PM1091016014Dennis WhyteEarly disruption



Oct 16 2009 12:40:13:840PM1091016015Dennis WhyteEarly disruption



Oct 16 2009 01:00:23:333PM1091016016Dennis WhyteHigher X-point, kappa 1.67

Avoided injections... good!

NL04=0.9

Again we see apparent H-mode dithers due to sawtooth.

I-mode? hard to tell with dithering. Stored energy
much lower than 1.35 MA 1080416028 shot.

No definitive H-mode transition: so up power on next shot.








Oct 16 2009 01:19:38:387PM1091016018Dennis WhyteDisrupted again.

It looks like we are really struggling with q95 hovering
around 3 and the plasma's have very high disruptivity.

We are going to try get the density scan at a higher
q95~3.45 at lower Ip to help with disruptivity.








Oct 16 2009 01:37:58:317PM1091016019Dennis WhyteDithering H-modes again. higher q95 but
we did not get a clear H-mode transition.
This makes me worry that we pushed the X-point
so high that we're not far from limited (or
we are limited) and this is giving atypical results.
Next
Will keep other things the same and lower X-point by 5mm.
Also will lower RF power slightly since we expect
H-mode threshold to be lower.










Oct 16 2009 02:21:43:873PM1091016022Dennis WhyteDithering improved with lower X-point.
An interesting observation is that the dithering
seemed to diminish (i.e. less H-modes) as we
increased the RF power through the shot.

q95=3.3, NL04 = 0.9, kappa = 1.65, Wth~150 kJ
at 1.15 seconds, H98~0.9

Prad has some positive time derivative.

No H-modes (except dithers)

But we had injections at 0.9 and 1.2, the last
of which disrupted the plasma








Oct 16 2009 02:46:22:117PM1091016023Dennis WhyteSwept the strikepoints to avoid big injections.
And we didn't get a disruption...check! but
still injection at 0.7 s.

Qualifies as I-mode. H98>0.9, toasty pedestal: ~700 eV
160 kJ stored energy.

Earl reports Zeff ~ 4... huh?
Almost 1e14 n/s.

Quite repetitive ELMs.




Oct 16 2009 02:59:03:340PM1091016025Dennis WhyteSweeps were started earlier. Shot ran through.
Impurity injection or source at 1.3 s at the last
RF step up which degraded the confinement.

L-mode ELMs again.

8e13 n/s, H98~0.95, Prad ~ 3 MW

It almost seems like there is a weak particle transport
barrier in this shot. Not really H-mode, but similar.
Up to 4.8 MW without H-mode transition.

Step 4, NL04=0.9


Oct 16 2009 03:06:49:623PM1091016026Dennis WhyteStep 4, NL04=0.7

Performance was actually degraded compared to the NL04=0.9 shot.
This looks to be due to higher radiated power (despite lower density!)
leading lower pedestal Te and lower stored energy ~ 125 kJ.
No H-mode even with 4.7 MW of RF power. Got a disruption
at the last power step.




Oct 16 2009 03:41:07:387PM1091016028Dennis WhyteStep 4, NL04=1.0 q95 ~ 3.3

Very good I-mode shot. Got a brief H-mode at 1.45 s at 4.8 MW RF

Some wild behavior in this as power goes up, the "h-mode" dithers
seem to go away?
One can see the effect of LBO at 0.8, 1 1.2 seconds. There
are hints at lower power that the plasma retains the impurities
longer, but not at higher power when Prad tends to decrease?

Neutrons over 1e14 n/s.

Wth up to 180 kJ.


Oct 16 2009 03:54:46:000PM1091016029Dennis WhyteStep 4, NL04=1.1 q95 ~ 3.3

H-mode at 0.98 s at 4.4 MW

Nominal I-mode (very brief) between 0.9 and 0.98 s.

Interesting evolution of the separtrix Te with the
small step in RF. Suggest something more
like a "transition" to I-mode.



Oct 16 2009 04:06:50:930PM1091016030Dennis WhyteStep 4, NL04=1.2 q95 ~ 3.3

D tripped out so not so interesting.

Lots of injections.

I've had it... here comes some neon


Oct 16 2009 04:23:54:170PM1091016031Dennis WhyteStep 4, NL04=1.2 q95 ~ 3.3

/w neon injection

Shot cleaned up, but pedestal stayed cold


Oct 16 2009 04:41:44:223PM1091016032Dennis WhyteStep 4, NL04=1.0 q95 ~ 3.3

/w neon injection

Much cleaner than 28 but the neutron count is lower
probably too much neon? (Matt's suggestion)
A very nice late I-mode but not so stationary
There is a strong Prad reduction at 1.3 second, then
T_ped starts increasing and we get a nice I-mode
Stored energy goes up to near 200 kJ and we get a
clear H-mode transition at 1.44 s.

Very interesting transition



Oct 16 2009 04:55:20:383PM1091016033Dennis WhyteStep 4, NL04=1.0 q95 ~ 3.3

/w neon injection but 1.1 psi in plenum

Much cleaner than 28 and the neutron count
in the 3rd power step was very constant at 1.2e14 n/s
No ELMs
Clear break in slope / transition into I-mode
in the 3rd RF step.

With apologies to the C-Mod team: this is a trophy shot


Physics Operator Comments
Oct 16 2009 07:26:32:273AMSteve Wolfe
Starting setup for Friday run MP#579
Reports from the alternator drive repair last night are favorable,
alternator is presently at 501rpm and rising. At this point we anticipate
an on-time start at 9:00

PCS setup:
load from 1091009013 (1.35MA, TF=-156.4ka,nl04=8e19)
Seg2:
Change zcur program from -.005 to +.001 to adjust elongation;
  I think my original estimate may be off (small) by a factor of two,
  but I don't want to go too far at 1.35MA close to q=3
Clearin at .294s from -.022 to -.0025 for earlier diversion
nl04 flattop from 8 to 5e19 starting at 0.6sec,
max from 1e20 to 8e19 at .34sec 

Seg1: 
PG4 is at 55msec (end at -.3sec instead of -.5)
Has a big pg3 puff in seg1; leave it for now, scale back later?
rcur offset=2000
Br_0 offset=0.0005
EF4=-1300
* set zcur to 0 at/after 0.1sec
Load at 16-Oct-2009 07:26:21.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done


Oct 16 2009 07:38:22:543AMSteve Wolfe
Continuing setup for first shot:
Note that seg1 pg3 puff starts at .05sec. Why??
Move start of pg3 to .025, lower last half to 50V
Also note that initial TF is at -156.4kA, like seg2; won't hurt, leave it.
Load at 16-Oct-2009 07:38:08.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done


Oct 16 2009 09:07:17:123AM1091016001Steve Wolfe
Shot#1: Attempt at 1.35MA USN like 1091009013 with 
 nl04=5e19, higher zcur (lower kappa), earlier divert.
Likely issues: early vde, locked mode, q=3, early strike location

Result: early disruption around 0.4sec, vertical problem, 
also q95 just under 3. Doesn't look like a locked mode, 
hadn't really diverted yet. 

Oct 16 2009 09:42:15:960AM1091016002Steve Wolfe
Shot#2: reduce pg4 from 55 to 50msec
slow down clearin increase (start ramp at .2, end at .38); 
may have found out why the divert was so late in the original?
Complicated by oh1 crossover around 0.3sec, that seems to be
the only supply other than efc that rails, but the ef2 lag was
the cause of the vertical issue I think. 

Result: disrupts at .67sec in flattop. 
q95=2.9, kappa=1.67, rf is on at 2.5MW, nl04=6.5e19
There is an injection starting at .669sec that causes a 
rise in voltage demand. That could be the problem or it could be
q=3. 

Next: raise zcur to +6mm, try again


Oct 16 2009 09:46:41:010AM1091016003Steve Wolfe
Shot#3: raise zcur to +6mm, try again, no startup change. 
result: fizzle


Oct 16 2009 10:10:29:080AM1091016004Steve Wolfe
Shot#4: Try again, no dpcs change let it clean up.
 raised zcur to +6mm from .001 (for #3)

result: disrupts around the same time, got kappa=1.64,q95=2.88
First thing still seems to be halpha increase (injection?) .645sec
I don't think there's a locked mode, and I don't see a mag fluct until
right at the disruption, but it still could be 3/1. 

Try again with no rf

Oct 16 2009 10:19:04:253AM1091016005Steve Wolfe
Shot#5: Try again with no rf, see if that injection is related or even 
relevant. 

disrupts at same time, so it's not the rf. 
sawteeth look a bit ratty, locked mode?
Try raising density back to 8e19, turn rf back on. 

Oct 16 2009 10:26:52:367AM1091016006Steve Wolfe
Shot#6: Try raising density back to 8e19 in flattop, peak at 1e20,
turn rf back on.
 drop nl04 gain from 9 to 5 before .5sec
result: fizzle cryopump dump. 1e-5 at pulse 

Oct 16 2009 10:47:54:690AM1091016007Steve Wolfe
Shot#7: repeat.
Try raising density back to 8e19 in flattop, peak at 1e20
 drop nl04 gain from 9 to 5 before .5sec
cryo seems to be holding this time (Sue has it on manual)
result: same disruption time. 
still lousy density control, probably still getting a locked mode
looks like it sticks/slips with about 25msec period after .45sec,
not as obvious on sawteeth as usual though.

Next: put in some pg3 feedforward

Oct 16 2009 11:02:13:303AM1091016008Steve Wolfe
Shot#8: pg3 to 40V between .32 and .43sec
raise NL04 D gain to 10
4.3e-7 at init, not sure cryo is pumping properly

result: made it through, injection at 1.2sec, 
ELMs probably I-modish, density is unsteady but no big dips, averaging around 8e19, don't seem to be h-modes
gas is trying to follow
kappa=1.635, q95=2.87

Oct 16 2009 11:11:21:087AM1091016009Steve Wolfe
Shot#9:nl04 P=5, D=10 all the way through
 pg3 to 20V after .43sec. Trying to smooth out density
result: runaways early, disrupts at 1.25sec (where the injection happened on 8)

Next: raise pg4, increase rcur by 2mm to decrease outer gap.



Oct 16 2009 11:23:16:827AM1091016010Steve Wolfe
Shot#10:raise pg4 from 50 to 54msec, add to pg3 in seg1 (deal with runaways)
increase rcur by 2mm (to .658) to decrease outer gap (will decrease kappa)
leave rxu alone (SL was considering decreasing triangularity)
cryopump burped in init, coming back down... 4.5e-7 in check

Result: fizzle, probably too much pg4, I think cryo was ok. 
Would be nice if the ratiomatic was working!
Chalk it up to the disruption

Next: repeat



Oct 16 2009 11:34:43:097AM1091016011Steve Wolfe
Shot#11: RXU out by 1cm to -.03 (SL changed his mind)
Changes made for shot#10:
pg4 at 54msec, added to pg3 in seg1 (deal with runaways)
increased rcur by 2mm (to .658) to decrease outer gap (will decrease kappa)

result: fizzle. 
Next: pg4 back to 50msec




Oct 16 2009 11:53:23:337AM1091016012Steve Wolfe
Shot#12: PG4 from 54 to 50msec
Change made for #11: RXU out by 1cm to -.03 
Changes made for shot#10:
added to pg3 in seg1 (deal with runaways)
increased rcur by 2mm (to .658) to decrease outer gap (will decrease kappa)
Note: RGA died several shots ago, so we're really flying blind on vacuum
IGT 2.5e-7 at INIT (was over 4e-7 last shot)

result: disrupted earlier, .87sec
Looks like the shape changes did as intended, du drops to .63,
q95=2.88, k=1.64. 

next: move zxu up closer to plate. 


Oct 16 2009 12:07:31:373PM1091016013Steve Wolfe
Shot#13: zxu from .005 to .01
igt=4.9e-7 at INIT (cryo on)

result: disrupts at 1.07sec
something bad happens at 0.9sec, injection seem on bolo, not on halpha
density and Te both drop, maybe some core mhd there triggered by st

Next: raise ZXU again

Oct 16 2009 12:23:19:083PM1091016014Steve Wolfe
Shot#14: zxu from .01 to .015
raise nl04 from 8 to 9e19

result: early disruption .3sec, something may come in at .29, 
but it's not huge. oh1 crowbarred, pf breaker pulled, after the disruption

Next: repeat


Oct 16 2009 12:41:22:793PM1091016015Steve Wolfe
Shot#14: repeat
zxu at.015
nl04 at 9e19
2.3e-7 in init

result: another short disruption, with runaways this time.
0.24sec this time, I know I didn't change anything that early. 
marfe starts at ..2, radiation goes up, voltage goes up.
The only change was zxu point at .564, but it's just possible that
the interpolation to previous point at .238 matters,so insert an anchor
at .4sec to keep everything before that fixed as on 13. 

Next: 

Oct 16 2009 12:55:01:003PM1091016016Steve Wolfe
Shot#15: Anchor zxu trace at 0.4sec to be the same as #13,
just to be sure. decrease pg3 in seg1
zxu at.015
nl04 at 9e19
2.3e-7 in init

result: made it through rampdown, no runaways, some elms or maybe dithers
k=1.68, q95 is up to 3.1, aout=.22, Wmhd=151kJ

Next: repeat at higher rf power

Oct 16 2009 01:10:26:413PM1091016017Steve Wolfe
Shot#16: repeat at higher rf power
2.8e-7 in init

Result: Another early disruption, with runaways. 
goes at 0.46sec, just after it goes diverted, almost to flattop, q05=3.1
There are a couple of injections at .3, .4sec, but not huge. 
no marfe. could be q=3 problem. 

Next: pg4 to 52


Oct 16 2009 01:16:05:730PM1091016018Steve Wolfe
Shot#18: raise pg4 from 50 to 52msec, try again at higher rf power
2.6e-7 in init

Result: disrupts at .7sec, still has runaways
injections at .5sec, 

Next: go to 1.2MA, get well away from q95=3


Oct 16 2009 01:30:07:720PM1091016019Steve Wolfe
Shot#19:  go to 1.2MA, get well away from q95=3
pg4 to 54msec


Result: plas,ma disrupts at 1.4sec, still runways. 
Little H-modes. small injection at 0.9sec, bigger one at the end.
k=1.67, q95=3.4

Next: Drop zxu by 5mm, raise pg3 in seg1


Oct 16 2009 01:42:16:910PM1091016020Steve Wolfe
Shot#20: Drop zxu from .015 to .01, raise pg3 in seg1
drop tf in seg 1 to -150kA: it's actually still rising at t=0,
want to eliminate variability, small Bz, index change from normal

Result: fizzle. I'm going to blame it on the previous disruption,
rather than the seg1 changes I made. 

Next: repeat


Oct 16 2009 01:52:56:133PM1091016021Steve Wolfe
Shot#21: Repeat
Changes for shot#20:
Dropped zxu from .015 to .01, raised pg3 in seg1
dropped tf in seg 1 to -150kA to eliminate variability, small Bz, 
index change from normal start

Result: fizzle

Next: drop pg4 back to 50msec


Oct 16 2009 02:13:15:580PM1091016022Steve Wolfe
Shot#22: drop pg4 from 54 to 50msec
Changes for shot#20:
Dropped zxu from .015 to .01, raised pg3 in seg1
dropped tf in seg 1 to -150kA to eliminate variability, small Bz, 
index change from normal start

Result: plasma disrupts at 1.25sec, runaways still there. 
Injection at .87 takes a bite out, another at 1.2sec kills
up to 150kJ, 4MW. 

Next: put in an rxu sweep to try to reduce melting

Oct 16 2009 02:25:15:200PM1091016023Steve Wolfe
Shot#23:  put in an rxu sweep between -.03 and -.04 and back again
Pushed the button too soon, Yijun didn't get the last rf step programmed

result: plasma made it through, still has runways
Elms are back, one big injection at .75sec, smaller one at 1sec
up to 160kJ at 4.2MW

Next: increase pg3 again

Oct 16 2009 02:35:52:363PM1091016024Steve Wolfe
Shot#24:  increase pg3 again, trying to get rid of the runaways without fizzling

result: disrupts at .7, the injection got it that time. 

next: reverse the phase of the rxu sweep

Oct 16 2009 02:51:25:180PM1091016025Steve Wolfe
Shot#25: reverse the phase of the rxu sweep,
which means it will be moving at 0.7sec
move seg1 rcur in from .64 to .63 at .05sec

Result: plasma full length, with runaways
Injection at 1.3sec but it survives; seems to coincide with final rf step.
Up to 165kJ, ELMs are present between 1 and 1.3sec 

next: nl04 to 7e19


Oct 16 2009 03:03:54:780PM1091016026Steve Wolfe
Shot#26:  nl04 from 9 to 7e19
reduce feedforward from 20 to 10V

Result: plasma with runaways, disrupts at 1.3sec
density was down to 7e19, Wmhd=125kJ, 

Next: raise density

Oct 16 2009 03:16:27:457PM1091016027Steve Wolfe
Shot#27:  nl04 from 7e19 to 1e20
raise feedforward from 10 to 30V
Resist urge to raise pg4 again
Ed is now waiting 12min for magnet cooling to reduce ratcheting

Result: fizzle

Oct 16 2009 03:28:59:820PM1091016028Steve Wolfe
Shot#28: tweak reverse rxu sweep so it doesn't go to the corner until 1.5sec
nl04 from 7e19 to 1e20
raise feedforward from 10 to 30V
Have Tommy pump out bside lower and fill with 2psi neon, 
in case SL decides we want to try it. 

Result: plasma full length, runaways, ELMs, H-mode at the EOF
This shot had it all. Up to around 180kJ

Next: nl04 to 1.1e20

Oct 16 2009 03:47:14:750PM1091016029Steve Wolfe
Shot#29:  nl04 to 1.1e20
feedforward puff up to 50V start, 40V level
NL04 gain from P=5 to 7 after 0.7sec

result: plasma full length, big injection at 1.1
h-modes at .95 and 1.3sec, second one gets over 210kJ
Still have runaways early. 

Next: nl04=1.2e20


Oct 16 2009 03:59:31:020PM1091016030Steve Wolfe
Shot#30:  nl04 to 1.2e20, leave pg3 alone

Result: plasma full length, lots of runaways,
no h-mode this time, small injections all through
less power, D tripped early, got to 4MW max

Next: Repeat, enable B-side lower (neon)


Oct 16 2009 04:18:39:027PM1091016031Steve Wolfe
Shot#31:  nl04 at 1.2e20, try for full rf,
puff neon from 550 to 750msec (2psi)
pg4 from 50 to 52ms

Result: plasma full length, runaways beter, H-mode at the end, 
one injection .8sec, but survives and prad drops during rest of shot
Got the RF, everything is much steadier. 

Next: NL04 back to 1.0e20, increase neon puff length 

Oct 16 2009 04:35:24:017PM1091016032Steve Wolfe
Shot#32:  nl04 from 1.2 to 1e20, seg2 pg3 to 40/30V
leave puff neon from 550 to 750msec (2psi)

result: plasma full length , no runaways, H-mode at the end.
No injection this time, looks like an I-mode transition at 1.3sec
Maybe neon is pumping out then, prad drops at rf power increase

Next: reduce neon to 1.25psi and repeat

Oct 16 2009 04:46:15:163PM1091016033Steve Wolfe
Shot#33:  reduce neon to 1.1psi and repeat with same timing (.55 to .75)

result: plasma full length, neuts steady at 1e14/sec from 1.2 to 1.5sec
in I-mode, H-mode at EOF, raises the Prad. 

Next: raise Ip to 1.35MA
Or not, SL is thinking again


Oct 16 2009 05:01:58:670PM1091016034Steve Wolfe
Shot#34:  raise Ip to 1.35MA, 1.1e20, leave feedforward as is
leave Neon puff @1.1psi .55 to .75sec

plasma full length with 2 H-modes, up to 1.7e15neut/sec
W=237kJ, but prad is screaming up in each H-mode, probably 
needed more neon for the H-mode. 

END OF RUN, maybe come back to it later. 



Engineering Operator Comments
ShotTimeTypeStatusComment
109:00:13:230AMPlasmaOk
209:25:46:100AMPlasmaOk
309:44:50:790AMPlasmaOk
409:57:36:450AMPlasmaOk
510:10:49:783AMPlasmaOk
610:23:46:083AMPlasmaOk
710:38:47:183AMPlasmaOk
810:52:17:470AMPlasmaOk
911:05:28:070AMPlasmaOk
1011:19:12:467AMPlasmaOk
1111:32:06:080AMPlasmaOk
1211:44:50:023AMPlasmaOk
1311:57:40:560AMPlasmaOk
1412:12:22:987PMPlasmaOkOH1 self powered circuit fired after disruption
1512:31:08:290PMPlasmaOk
1612:44:35:343PMPlasmaOk
1712:57:40:143PMPlasmaOk
1801:11:23:570PMPlasmaOk
1901:24:09:717PMPlasmaOk
2001:38:04:160PMPlasmaOk
2101:50:48:460PMPlasmaOk
2202:03:29:060PMPlasmaOk
2302:17:55:310PMPlasmaOk
2402:30:28:453PMPlasmaOk
2502:43:03:490PMPlasmaOk
2602:56:31:383PMPlasmaOk
2703:11:42:047PMPlasmaOk
2803:24:20:990PMPlasmaOk
2903:39:27:370PMPlasmaOk
3003:53:59:737PMPlasmaOk
3104:09:22:943PMPlasmaOk
3204:24:50:247PMPlasmaOk
3304:40:21:207PMPlasmaOk
3404:56:03:603PMPlasmaOk

System Availability
Oct 16 2009 08:59:46:950AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (diode+foil), AXA, AXJ, WB3AX, WB4AX, LEDGE-AX working fine. MID-FOILS working fine. The LEDGE/DIV foils still need calibrations appliedAug 27 2009 09:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoBottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel AccessMay 30 2008 02:25PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoCyopump hardware is not yet reinstalled in the cell.Jul 14 2009 09:21PM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationnosafely disabled; ready to be dismantledMay 28 2008 10:22AM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnopower locked & tagged out; gate valve disabledMay 28 2008 10:03AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCno6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel ActivityJun 10 2009 02:35PM (dekow)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll 32 channels working and calibrated.Oct 06 2009 11:17AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Controller repaired.Aug 23 2009 10:36PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATnoDisconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work.Jun 04 2008 12:24PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesoperational at 80 MHzJul 21 2009 04:49PM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesantenna and FFT operationalJul 21 2009 04:49PM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesavailable at 80 MHz and [0,pi,0,pi] phasingSep 04 2009 10:01AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data. WB1-LY not attached.Aug 27 2009 09:10AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesOperating normallyAug 27 2009 09:10AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Recalibrated 7/27/09.Jul 28 2009 04:22PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesOperational --- Uncalibrated and needs to be positioned at portJun 25 2009 05:08PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCInoDown. Will not be fixed until vent.Sep 24 2009 09:10AM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,edlund,ennever,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyesOperational ---- ECDC running as required Jun 19 2009 08:06AM (irby)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesSince 1090824xxx, all channels are operational.Aug 25 2009 09:31AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasmaJun 18 2009 01:01PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes2 lasers working. 15 spatial channels operational. Calibrated Oct 13 2009 07:49PM (yma)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgeyesOperational, and calibrated.Oct 11 2009 03:01PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyesOperating normallyAug 27 2009 09:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke

Oct 16 2009 12:57:18:643PM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (diode+foil), AXA, AXJ, WB3AX, WB4AX, LEDGE-AX working fine. MID-FOILS working fine. The LEDGE/DIV foils still need calibrations appliedAug 27 2009 09:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoBottle Removed from the Cell, Piezo box on Igloo Removed. System in safe mode for In-Vessel AccessMay 30 2008 02:25PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoCyopump hardware is not yet reinstalled in the cell.Jul 14 2009 09:21PM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationnosafely disabled; ready to be dismantledMay 28 2008 10:22AM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnopower locked & tagged out; gate valve disabledMay 28 2008 10:03AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCno6/10/09 Magnetron relocated to west wall in cell at H-port. All controls and hardware have been installed but need to be tested prior to full operation. Magnetron Unplugged and Red tagged, PEI breaker red tagged, Safe for In-Vessel ActivityJun 10 2009 02:35PM (dekow)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll 32 channels working and calibrated.Oct 06 2009 11:17AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Controller repaired.Aug 23 2009 10:36PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATnoDisconnect switch is open, reg tagged and locked. Shunt Trip Breaker is opened. Safe for in-vessel work.Jun 04 2008 12:24PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesoperational at 80 MHzJul 21 2009 04:49PM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesantenna and FFT operationalJul 21 2009 04:49PM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesavailable at 80 MHz and [0,pi,0,pi] phasingSep 04 2009 10:01AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-OffyesRequires some advance notice for laser start-upOct 16 2009 12:46PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data. WB1-LY not attached.Aug 27 2009 09:10AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesOperating normallyAug 27 2009 09:10AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Recalibrated 7/27/09.Jul 28 2009 04:22PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesOperational --- Uncalibrated and needs to be positioned at portJun 25 2009 05:08PM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCInoDown. Will not be fixed until vent.Sep 24 2009 09:10AM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,edlund,ennever,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyesOperational ---- ECDC running as required Jun 19 2009 08:06AM (irby)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesSince 1090824xxx, all channels are operational.Aug 25 2009 09:31AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker now at K-Hor. Set for 100 uA of current. Will up to 200 uA before first plasmaJun 18 2009 01:01PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes2 lasers working. 15 spatial channels operational. Calibrated Oct 13 2009 07:49PM (yma)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgeyesOperational, and calibrated.Oct 11 2009 03:01PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyesOperating normallyAug 27 2009 09:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke

Oct 16 2009 02:54:03:540PM
350 C delta-T on K Limiter. Every good shot is heating it up. Maybe the earlier disruptions were it trying to defend itself from the threat of melting.