Alcator C-Mod Run 1091204 Information

Back to runs

Miniproposals
Miniproposal:586a
Date Filed:11/25/2009
Title:Impurity Transport Studies in L-mode Plasmas
First Author:Nathan Howard
Session Leader:Nathan Howard (shots 1-30)

Operators
Session leader(s):Nathan Howard
Physics operator(s):Robert Granetz,Earl Marmar
Engineering operator(s):Bill Parkin,Sam Pierson,Ed Fitzgerald

Engineering Operator Run Comment
MP586a- Impurity transport, L-mode

Session Leader Plans
Entered: Mar 3 2010 03:10:41:307PM
Author: Nathan Howard
Impurity Transport Studies in L-Mode Plasmas
Full day of 1.5 Days (Other run was 1091202xxx 2nd half)
---------------------------------------------------------------------

This is a continuation of the run started on 12/02 in the afternoon.


The purpose of these experiments is to use the newly commissioned laser blow-off system to investigate the dependence of the impurity fluxes as a function of local plasma parameters through scans in safety factor, input power, and density. This will allow for a more general characterization of the particle flux that can directly be compared with turbulent transport theories as well as provide insight into the relevant factors into the impurity flux for later experiments.

The list of target plasmas for each shot is presented below. This experiment consists of parameter scans in ne (nl04 of .6, .9, 1.2, 1.5x10^20), Ip (.6, .8, 1.0, 1.2 MA), and Pin (ohmic, 1.0, 2.0, 3.0, 4.0 MW) for effective scans in density, q95, and Te.
---------------------------------------------------------------------

USN Reference shot: 1091202034 (for equilibrium only, see below for RF, Bt, etc.)
Cryopump: On
Working Gas Species: D2
Argon puffing for Er profiles from HiREX Sr.
Laser Blow-Off: Yes
Density: nl04 of .6, .9, 1.2, 1.5x10^20
Boronization Requested: No
Standard ECDC Overnight

Toroidal Field: 5.4 T
Plasma Current: .6, .8, 1.0, 1.2 MA

ICRF Power:
D & E antennae: 80 MHZ, maximum power
J-antennae: 78 MHz, maximum power needed to supplement D and E to get to 4 MW

RF power steps for all shots are programmed as the following: Until 0.7 sec: Ohmic, 0.7-0.9 sec: 1 MW, 0.9-1.1 sec: 2 MW, 1.1-1.3 sec: 3 MW, 1.3-1.5 sec: 4 MW (unless otherwise specified)

--Diagnostics:
---------------------------------------------------------------------
-ECE (all channels) for Te
-Thomson, edge and core, for ne and Te
-HIREX Sr., Rotation information and Er information
- McPherson (VUV), scanning shot to shot. Mostly on the outer half of the plasma to supplement the views provided LLNL spectrometer
- Soft X-ray arrays
- LLNL spectrometer (if available)
- HIREX Jr. (for He-like Ca line)
- Reflectometry (if available) during at least one injection period. (To verify injection as non-peturbative in a turbulent fluctuation sense and look for I-mode transitions at higher power.)
-PCI set up for low frequency, low k fluctuations digitized during the entire flat-top
-----------------------------------------------------------------------

--Shot Plan:
-----------------------------------------------------------------------
Each plasma shot will operate at a fixed density and current while the ICRF is incremented in 1 MW steps every 200 ms from .7 to 1.3 seconds. Initially 5 impurity injections will be introduced into the plasma approximately 65 ms after each RF step. This corresponds to injections at .565, .765, .965, 1.165, and 1.365 seconds. This number might be reduced to four injections if the inter-injection time is not sufficient to extract impurity transport information.

--------------------------------------------------------------------------
| This section was completed on 1091202019-034
--------------------------------------------------------------------------
| 1. At fixed density nl04= 0.6x 10^20 (1/m^3): Scan in Ip at fixed Bt=5.4 T | (4 |shots)
| Ip=0.6 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
| Ip=0.8 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
| Ip=1.0 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
| Ip=1.2 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
---------------------------------------------------------------------------

***************************
*** Start of 1091204xxx
***************************

2. At fixed density nl04= 0.9x 10^20 (1/m^3): Scan in Ip at fixed Bt=5.4 T (4 shots)
Ip=0.6 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=0.8 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=1.0 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=1.2 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)


3. At fixed density nl04= 1.2x 10^20 (1/m^3): Scan in Ip at fixed Bt=5.4 T (4 shots)
Ip=0.6 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=0.8 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=1.0 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=1.2 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)


4. At fixed density nl04= 1.5x 10^20 (1/m^3): Scan in Ip at fixed Bt=5.4 T (4 shots)
Ip=0.6 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=0.8 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=1.0 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
Ip=1.2 MA, 5 heating steps, Ohmic and 1-4 MW (1 MW steps)
-------------------------------------------------------------------
16 shots total (effective scans in T, n, and q)

Physics Operators Plans
Entered: Dec 3 2009 04:55:21:770PM
Author: Robert Granetz

Engineering setup for Friday 2009/12/04

MP586a- Impurity transport studies in L-mode

Session leaders: N. Howard
Physics operator: R. Granetz, E. Marmar

Overnight: usual ECDC in D2 and 60 C bake

Run will start at 09:00 and end at 17:00.

Power systems as on 1091202034 (USN w/cryopump)

A-coil configuration: +Dtop -Dbot -Jtop +Jbot; Enabled (standard
configuration)

Gas Setup:
   fill B-Top            with  6 psi D2  Hybrid enabled  (PG4)
   fill B-side lower     with  1 psi Ar  Hybrid DISABLED (PG1)
  leave B-side upper     as is           Hybrid DISABLED (PG2)   
   fill B-main (C-side)  with 40 psi D2  Hybrid enabled  (PG3)
  leave NINJA            as is           DISABLED

Enable the following gate valves and shutters, assuming no vacuum problems:
  ECE, VUV, Z-bolo
 
Torvac setup: keep gate valves open during PULSE

Specific diagnostics: Laser blowoff, new LLNL spectrometer

------------------------------------------------------------------------------
Boronization: no
ICRF Setup: all transmitters needed
LH Setup: no
DNB: no
Cryopump: yes, ready for the start of the run
------------------------------------------------------------------------------

Run plan: start from 1091202034.


Session Leader Summaries
Entered: Dec 5 2009 10:15:06:330PM
Author: Nathan Howard
MP586a Full Run Day

This run began well at the nl04 = .9e20 and .6 MA case in shot 2 and moved up in current from there. Despite some digitizer/analog output issues that caused the laser to stop working and required about 1.5 hours of troubleshooting, I was able to get 30 plasma shots. I achieved all of conditions at nl04 = .9 and 1.2e20 but was unable to access the 1.5e20 conditions because the neutral pressure limit for the RF was already becoming a problem at the lower density and therefore the temperature scan was not possible. At the high densities the RF was not as reliable and the scans in temperature were not as dramatic. Given that the Ip dependence of impurity confinement time was already easily characterized by the existing data, I chose to move lower densities (.4 and .75e20) and attempt to access some currents to provide a better density scan since the 1.5e20 cases were no easily achieved. Over the course of 1.5 run days a good scan in density, temperature, and current was achieved over a wide operational range. Initial results show that there might be a small density dependence of the impurity confinement which is seen most clearly at high densities but is not as evident at low density. The current dependence (increase in current increases impurity confinement) is once again very evident and at low density the temperature dependence seen on shot 12/02 is most obvious (decrease in impurity confinement with an increase in temperature). More in depth analysis will soon be performed.

Physics Operator Summaries
Entered: Dec 8 2009 03:28:53:717PM
Author: Earl Marmar
The machine ran well today, and we covered a good range of currents and densities. All shots were USN and the cryopump was on.

A number of the higher current shots had I-mode periods.

Changing the nl_04 feedback (increased derivative gain, decreased proportional gain) on shot 21 appeared with help with density oscillations

OH2L started misbehaving on shot 11; after shot 15, the engineers did some power resets on the supply, and it behaved after that.

scorecard:
Shot,Duration(s),Ipmax(MA),Result Shot,Duration(s),Ipmax,Result
| 01 0.512 0.042 Fizzle | 02 2.300 0.706 Plasma |
| 03 1.964 0.819 Plasma | 04 2.300 1.019 Plasma |
| 05 2.300 1.214 Plasma | 06 2.300 1.211 Plasma |
| 07 2.300 1.019 Plasma | 08 2.100 0.723 Plasma |
| 09 0.513 0.040 Fizzle | 10 2.290 0.802 Plasma |
| 11 0.520 0.058 Fizzle | 12 2.300 0.813 Plasma |
| 13 1.748 1.052 Plasma | 14 2.290 1.208 Plasma |
| 15 0.465 0.848 Plasma | 16 0.512 0.064 Plasma |
| 17 1.689 1.279 Plasma | 18 0.510 0.048 Fizzle |
| 19 2.220 0.733 Plasma | 20 0.504 0.044 Fizzle |
| 21 1.899 1.203 Plasma | 22 0.898 1.218 Plasma |
| 23 1.940 0.689 Plasma | 24 1.745 0.871 Plasma |
| 25 0.910 0.691 Plasma | 26 2.270 0.682 Plasma |
| 27 2.290 0.822 Plasma | 28 2.090 0.821 Plasma |
| 29 1.918 1.015 Plasma | 30 1.900 1.363 Plasma |

Date 1091204: 30 shots. 25 plasmas. 5 fizzles. 0 duds. 0 System Error.
(Plasma = Ip gt 60.0 kA Dud = H_alpha lt 0.40 V)
Total plasma duration: 49.50 s (exceeding -4 kA)

Session Leader Comments
Dec 4 2009 09:22:22:143AM1091204001Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=.6 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Actual: Fizzle.

Dec 4 2009 09:25:27:097AM1091204002Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=.6 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Actual: Good Injections, all 5. HiREX data looks good despite trips in the E antenna.

Dec 4 2009 09:41:38:970AM1091204003Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Actual: Good Injections, all 5. HiREX data looks good despite some odd RF. The max RF was 2.5 MW but an H-mode occurs at about 1.5 sec so I am moving on despite RF to avoid H-mode.

Dec 4 2009 10:32:36:520AM1091204004Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=1.0 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
The shot was good but there was a problem with the digitizer and the laser didnt fire. After a longer than desired break. I believe this problem has been resolved and due to the long break we are moving on to the next condition.

Dec 4 2009 11:31:09:520AM1091204005Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Digitizer problems occured again...working on resolving this problem. Will redo on the next shot
Dec 4 2009 11:32:28:910AM1091204006Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Good Shot. Small H-mode at the end. RF is pretty godo all the way through. 3 of the 5 injections are clear on HiReX but then high voltage started to trip. So I lost shot 4 on this shot. Given all of our delays...I am going to move on.
Dec 4 2009 11:44:44:957AM1091204007Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9x10^20
Ip=1.0 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Good Shot. Good Injections. Several H-modes at the end of the shot 1.1 and after and maybe a small I-mode period. This was a repeat of shot 4 which was the start of the laser problems.
Dec 4 2009 12:11:59:800PM1091204008Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=.6 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
At this current and density, the injections are peturbing the density. I am dropping the injection size for the next shot. Current is good but the neutral pressure limit is reached on J antenna so there are problems related to this. Hirex data looks decent but not great. I am going to move on to the next shot.
Dec 4 2009 12:10:44:470PM1091204009Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Fizzzzle...
Dec 4 2009 12:33:43:783PM1091204010Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Shot was good and injections were good but RF had some problems so the temperature was not raised much. Ill cross my fingers and try it again...
Dec 4 2009 12:40:41:003PM1091204011Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Fizzzzle...
Dec 4 2009 12:52:15:440PM1091204012Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
The RF was not as good as desired due to the low current and high pressure. Injections were ok although the density did not hit target except for maybe at the 2nd pulse. Hirex data looks pretty good. Moving on...
Dec 4 2009 01:19:03:253PM1091204013Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=1.0 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
The RF looks good overall and the density is a little low to start but reaches the desired. The temperature is low a little bit because of high radiated power. The injections were good but the last occurs after rampdown.
Dec 4 2009 01:24:38:520PM1091204014Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
The RF does a good job again. The density is nice and flat but struggles a little bit to reach 1.2. Injections look good and gave good signals except for at the highest RF step due to trips in the RF.
Dec 4 2009 01:37:44:690PM1091204015Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.5x10^20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Early disruption
Dec 4 2009 01:47:08:317PM1091204015Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.5x10^20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Fizzle...
Dec 4 2009 02:14:32:207PM1091204017Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.5x10^20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Density never reached 1.5e20 but still high density. Good Injections but crummy L-mode confinement. The temperature doesnt change significantly despite the good RF up to 4MW. HiRex data looks good. We are moving back down to 1.2 nl04 with .7 MA to try to get a low current point.
Dec 4 2009 02:18:15:300PM1091204018Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2x10^20
Ip=.7 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Fizzle. Could be power supply problems that were experienced earlier.
Dec 4 2009 02:40:43:207PM1091204019Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=1.2e20
Ip=.7 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Injections were good although the first one caused a spike in the density and so did the last one. The 3 in the middle look pretty good although RF at this density and current is only marginal. The core temperature during this time is fairly constant so there is no real scan with temperature unfortunately. Moving on to fill in old data points.
Dec 4 2009 02:51:12:533PM1091204020Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.6e20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Fizzzzle...
Dec 4 2009 03:15:34:113PM1091204021Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.6e20
Ip=1.2 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
The shot went well with good RF. E antenna was not reported...at least so far but I believe close to the desired heating was achieved. Density was pretty constant and temperature grew significantly over the course of the shot. We are going to retry because for some reason the last 2 pulses were not really picked up on HIREX.
Dec 4 2009 03:38:41:097PM1091204023Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.4e20
Ip=.6 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Good Injections and good RF. 4 of the 5 shots are good except the last of the injections. Density is basically at the target with some variation due to the RF and the Hirex data is good for all but the last point. We are moving on to the .8 MA case at the same density.
Dec 4 2009 03:53:41:567PM1091204024Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.4e20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Good Injections and good RF until about 1.3. 4 of the 5 shots are good except the last of the injections. Density is basically at the target with some variation due to the RF and the Hirex data is good for all but the last point. Since locked modes will probably come into play at higher current, we are moving down to .4 MA Ip.
Dec 4 2009 04:02:10:020PM1091204025Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.4e20
Ip=.4 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Disruption. Trying to move to an intermediate density of .75 for the next shot and scan in current for the remainder of the shots
Dec 4 2009 04:30:02:613PM1091204026Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.75e20
Ip=.6 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Good Shots overall. Dont really see the temperature dependence that is seen in other densities around this level or below. RF was pretty good and gave a pretty good increase in the core temperature. Moving up to .8 MA
Dec 4 2009 04:31:01:363PM1091204027Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.75e20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
------------------------------------------------------------
Good Shots....except Hirex tripped after the first 2. The RF was very good. Density was well controlled and temperature rose. I am going to repeat this shot.

Dec 4 2009 04:45:54:773PM1091204028Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.75e20
Ip=.8 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
-----------------------------------------------------------
Good Shot again. Small H-mode at around 1.2 sec. All injections were good with good signals. Temperature scaling is shown. Moving to 1.0 MA

Dec 4 2009 05:07:27:250PM1091204029Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.75e20
Ip=1.0 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
-----------------------------------------------------------
Good Shot at 1.0 MA. Good Injections on Hirex. I-mode for the last pulse so longer confinement time.
Dec 4 2009 05:09:08:517PM1091204030Nathan HowardTarget shot was:
-----------------------------------------------------------
Bt=5.4 T
nl04=.9e20
Ip=1.3 MA
RF: 1-4MW at 1 MW steps (.7,.9,1.1,1.3)
5 Injections: .565,.765,.965,1.165,1.365 sec (CaF2)
-----------------------------------------------------------
RF trips out some but high current and high RF. Injections 1 and 2 are good.

Physics Operator Comments
Dec 4 2009 09:08:04:097AM1091204001Robert Granetz
Shot 01 -- Fizzle.  Cryopump was on, and the pre-fill pulse was set at 57 ms, which was the right value
           yesterday morning.

Next shot: reduce pre-fill pulse to 54 ms

Dec 4 2009 09:25:04:457AM1091204002Robert Granetz
Shot 02 -- Plasma, full length.  0.6 MA, 5.4 T, nl_04=0.9e20 m-2 (target density), USN, cryopump on.
           Prf=2-3 MW.  E-port antenna had lots of faulting.

Next shot: enable B-side-lower (Ar puffs); increase Ip to 0.8 MA

Dec 4 2009 09:34:44:113AM1091204003Robert Granetz
Shot 03 -- Plasma, disrupted during rampdown.  0.8 MA, 5.4 T, nl_04=0.9-1.0e20 m-2, USN, cryopump on.
           No early hard x-rays.  Prf=2-2.6 MW.

Earl is taking over as physics operator.  (I was just substituting for the start of the run.)

Dec 4 2009 09:58:29:677AM1091204004Earl MarmarIp to 1.0 MA
reduce argon (remove second pulse, reduce first pulse to 75 ms)

plasma, full length
startup looks ok

2 H-modes, with an I-mode in between
Dec 4 2009 10:50:47:550AM1091204005Earl MarmarIp to 1.2 MA

plasma, full length
I-mode, with short H-mode at end of flat-top

impurity injector is having a timing problem
Dec 4 2009 11:40:06:347AM1091204006Earl Marmarno dpcs chnages

plasma, full length
nice I-mode, with short H-mode at end of flat-top

LBO worked on this one
Dec 4 2009 11:45:43:020AM1091204007Earl Marmarreload shot 4

plasma, full length
3 ELM-free H-modes, with short I-modes in between
Dec 4 2009 12:14:42:143PM1091204008Earl MarmarIp to 0.6 MA
nl_04 to 1.2e20

plasma, disrupt in rampdown
EF1 hitting limits
Dec 4 2009 12:15:03:113PM1091204009Earl MarmarIp to 0.8 MA
fizzle
fill looks high
Br also a bit high


Dec 4 2009 01:57:17:173PM1091204010Earl Marmarreduce prefill puff to 50 ms (from 54)
BR0 offset to 0.0000 (from +0.0005 T)

plasma, full length
Dec 4 2009 12:48:37:847PM1091204011Earl Marmarno dpcs changes

fizzle
OH2L did not get to the right current by t=0 (3% low)
Dec 4 2009 12:53:40:317PM1091204012Earl Marmarno dpcs changes

plasma, full length
Dec 4 2009 01:08:44:127PM1091204013Earl MarmarIp to 1.0 MA

plasma,

disrupt at 1.4 s
lots of radiated power leading up to the disruption
Dec 4 2009 01:33:43:940PM1091204014Earl MarmarIp to 1.2 MA

plasma, full length
Dec 4 2009 01:54:35:253PM1091204015Earl Marmarnl_04 target to 1.5e20

plasma, early disrupt
OH2L was way off at t=0, then breaker(s) pulled
Dec 4 2009 01:56:23:003PM1091204016Earl Marmarfizzle

looks a lot like shot 11, OH2L not getting there at t=0
engineers are looking into it.

Dec 4 2009 02:13:12:427PM1091204017Earl Marmarno dpcs changes

plasma
disrupt at 1.35 s, preceded by strong radiation increase
Dec 4 2009 02:26:25:880PM1091204018Earl MarmarIp to 0.7 MA
nl_04 target to 1.2e20

fizzle
nothing obviously wrong with fields
ratiomatic was off, so I'm not sure about gas pressure
Dec 4 2009 02:36:54:893PM1091204019Earl Marmarno dpcs changes

plasma, nearly full length
Dec 4 2009 02:53:10:470PM1091204020Earl MarmarIp to 1.2 MA
nl_04 target to 0.6e20, decrease prop gain, increase deriv gain

fizzle
Dec 8 2009 03:28:49:123PM1091204021Earl MarmarBR0 offset to +.0005 T (from 0.0000)
EF4 15 A more negative at t=0 (now -1315. A)

plasma, disrupt at 1MA in ramp-down
looking I-mode'ish late in the RF pulse, after step up to 3 MW
Dec 4 2009 03:23:02:003PM1091204022Earl Marmarreduce prefill puff to 47 ms (from 50 ms)

plasma
early disrupt (0.5 seconds)
a few hards
Dec 4 2009 03:38:05:580PM1091204023Earl Marmarprefill puff to 50 ms

Ip to 0.6 MA
nl_04 target to 4e19

plasma, disrupt early in ramp-down
Dec 4 2009 03:53:40:550PM1091204024Earl MarmarIp to 0.8 MA

plasma
significant hards

disrupt at 1.4 seconds
Dec 4 2009 04:03:50:970PM1091204025Earl MarmarIp to 0.4 MA

plasma
disrupt at 0.5 s
hards
Dec 4 2009 04:41:43:210PM1091204026Earl Marmarprefill puff to 55 ms (from 50 ms)

Ip to 0.6 MA
nl_04 target to 7.5e19

plasma, full length
Dec 4 2009 04:43:14:720PM1091204027Earl MarmarIp to 0.8 MA

plasma, full length
nice shot, with clean RF steps
H98~0.9 at the highest power
Dec 4 2009 04:44:05:460PM1091204028Earl Marmarno dpcs changes

plasma, disrupts halfway through ramp-down
early marfe, short H-mode later
Dec 4 2009 05:01:55:360PM1091204029Earl MarmarIp to 1.0 MA

plasma, disrupts early in ramp-down
Dec 4 2009 04:58:51:860PM1091204030Earl Marmarreload segment 2 from shot 6
Ip to 1.35 MA
nl_04 to .95e20

Engineering Operator Comments
ShotTimeTypeStatusComment
109:03:18:783AMPlasmaOk
209:16:20:783AMPlasmaOk
309:29:50:223AMPlasmaOk
409:43:21:253AMPlasmaOk
510:32:41:300AMPlasmaOk
611:23:50:660AMPlasmaOk
711:40:02:207AMPlasmaOk
811:53:23:330AMPlasmaOk
912:06:26:423PMPlasmaOk
1012:19:24:817PMPlasmaOk
1112:33:05:817PMPlasmaOk
1212:46:10:817PMPlasmaOk
1312:59:00:097PMPlasmaOk
1401:11:56:363PMPlasmaOk
1501:30:24:643PMPlasmaOkOH Comm Fault
1601:44:29:487PMPlasmaOk
1702:02:19:363PMPlasmaOk
1802:15:11:470PMPlasmaOk
1902:28:06:050PMPlasmaOk
2002:46:39:973PMPlasmaOk
2103:00:37:830PMPlasmaOk
2203:15:38:567PMPlasmaOk
2303:28:25:160PMPlasmaOk
2403:41:23:270PMPlasmaOk
2503:54:03:770PMPlasmaOk
2604:08:39:627PMPlasmaOk
2704:21:19:597PMPlasmaOk
2804:34:23:800PMPlasmaOk
2904:49:20:957PMPlasmaOk
3005:02:08:690PMPlasmaOk

System Availability
Dec 4 2009 09:02:54:910AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (diode+foil), AXA, AXJ, WB3AX, WB4AX, LEDGE-AX working fine. MID-FOILS working fine. The LEDGE/DIV foils still need calibrations appliedAug 27 2009 09:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationyes Nov 13 2009 06:37AM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesOperationalNov 09 2009 09:12AM (irby)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationyesoperational, but turned offNov 03 2009 04:59PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnoin test mode onlyNov 03 2009 05:01PM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCyes Nov 09 2009 09:13AM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll 32 channels working and calibrated.Oct 06 2009 11:17AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Controller repaired.Aug 23 2009 10:36PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Oct 27 2009 10:39AM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesoperational at 80 MHzJul 21 2009 04:49PM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesantenna and FFT operationalJul 21 2009 04:49PM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesavailable at 80 MHz and [0,pi,0,pi] phasingSep 04 2009 10:01AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-OffyesRequires some advance notice for laser start-upOct 16 2009 12:46PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data. WB1-LY not attached.Aug 27 2009 09:10AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesOperating normallyAug 27 2009 09:10AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Recalibrated 7/27/09.Jul 28 2009 04:22PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesPower back on morning of 11/09 before runNov 09 2009 09:10AM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesOperational.Nov 12 2009 02:36PM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,edlund,ennever,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Nov 13 2009 06:38AM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesSince 1091112000, 110 channel has been reinstalled. All channels are operational.Nov 12 2009 09:19AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker back in operation before 11/09 runNov 09 2009 09:11AM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes2 lasers working. 15 spatial channels operational. Calibrated Oct 13 2009 07:49PM (yma)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgeyesOperational, and calibrated.Oct 11 2009 03:01PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyesOperating normallyAug 27 2009 09:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke