Alcator C-Mod Run 1100302 Information

Back to runs

Miniproposals
Miniproposal:502
Date Filed: 7/12/2007
Title:HIREX-SR Calibration Plasmas
First Author:Matt Reinke
Session Leader:Matt Reinke (shots 25-32)
Miniproposal:593
Date Filed: 1/10/2010
Title:Vertical Equilibrium Shifts for Triggering ELMs
First Author:Jerry Hughes
Session Leader:Jerry Hughes (shots 1-24)

Operators
Session leader(s):Jerry Hughes,Matt Reinke
Physics operator(s):Steve Wolfe
Engineering operator(s):Bill Cochran,Andy Pfeiffer,Gary Dekow

Engineering Operator Run Comment
automatically entered by signon - please replace with real comment

Session Leader Plans
Entered: Mar 1 2010 01:01:58:620PM
Author: Matt Reinke
At the end of the day we'll attempt to finish the work started on 1100226 for MP502 - HIREXSR Calibrations.

During the MP593 run, piggyback on getting the full spatial profile of He-like argon centered on the x3 detectors. Use possible/requested cell accesses if necessary.

Test H-like/He-like vignetting
===============================
1) Load 1100226015 (USN, 1 MA, nl04~0.72, w/ cryopump and steady 0.5 psi Ar puff from 0.4 < t < 1.4)

2) run shots w/ and w/o He-like crystal mask, checking for vignetting after each pair of shots and, if necessary, adjusting crystal/enclosure.

3) run shots w/ and w/o H-like crystal mask like (2) at the same time as (2).




Entered: Mar 1 2010 11:07:50:710PM
Author: Jerry Hughes
Run plan for 1100302
MP 593: Vertical equilibrium shifts for triggering ELMs
SL: Jerry Hughes
PO: Steve Wolfe

This run will attempt to induce and perhaps synchronize useful ELMs in normally
ELM-free H-modes, and in I-modes. We will plan to take shots until 15:00, and
then turn over the run to Reinke et al. and MP502.

Prep:

-- Working Gas Species: Deuterium
-- ICRF at 80 MHz at 4--5 MW level.
-- Special gas puffing:
1psi Ar puff enabled, puff at 0.3s, 50ms in length
10psi D2 NINJA puff enabled for GPI, CXRS --- please consult SL before
triggering NINJA puff.
-- A-Coils: Standard configuration
-- LBO may piggyback near end of flattop --- please request SL permission
before actually firing.
-- Cryopump should be available for beginning of run

Required Diagnostics and their set up:
1.) Edge TS, no position changes.
2.) ECE. Optimize for pedestal top
3.) 0-D Fast D-alpha for ELM timing
4.) Fast magnetics. Digitize for full length of shot.
5.) Fast EFIT set up from 0.8 to 1.1s

Desired diagnostics:
1.) Passive and GP-assisted CXRS.
2.) PCI. Unmasked configuration, digitizing from 0.4 to 1.6s.
3.) Reflectometer. Set 0.5s digitization window to begin at 0.8s.
4.) Fast D-alpha GPI.
5.) Bolometry.
6.) Lyman alpha.
7.) HIREX Sr.

Run plan:

The initial part of the run will concentrate on trying to make ELM-free H-modes
less transient by inducing ELMs. Cryopump should be cold.

1. Reload 1100209028, an Ip=1MA, Bt=5.4T, nl04=1e20 shot with an EDA H-mode and
~200Hz ZCUR modulation from 0.9 to 1.4s. Repeat this shot, keeping ICRF
demand the same (on at 0.6s, ramping to 3.3MW at 0.8s. This will provide a
comparison shot in a poorly boronized machine. Next, increase ICRF demand
until max available power is put into the flattop (3--4 shots)

2. Keeping modulation the same, delay RF onset so that the gap between H-mode
formation and vertical jogging decreases. Exact amounts to delay should be
chosen based on the results of (1). The goal is to get the modulation
started earlier in the H-mode formation, before the impurity buildup cools
the plasmas. We may take want to extend the delay so that the modulation
begins _before_ the L-H transition. (2--3 shots)

3. Try to further weaken any QCM oscillation that might exist by lowering
density. Decrease nl04 to 0.8e20, then 0.6e20. (2--3 shots)

4. If (1--3) have managed to produce a condition where the modulation appears
to be regulating the H-mode in an interesting way, run some control shots
without modulation. (0--4 shots)

The second part of the run will look at I-mode.

5. Load shot 1091203015 (1.2MA, 5.6T). This was an I-mode shot with sawtooth-
triggered ELMs at ~50Hz. Attempt to reproduce this using ~5MW of ICRF. Next
insert ZCUR modulation from 0.9 to 1.4s. Choose a drive frequency close to
100Hz, but not right on double the sawtooth frequency.
Parameters: Period= 9, 10, or 11ms ModMax= -.004m, ModMin=0.0m ,
trampup/down=.002 s
Adjust mod parameters as needed to maintain vertical stability and look
for ELM triggering/pacing. (2--5 shots)
Note: The shot we are loading from had a large Ne pulse, which we are not
going to use.

6. Load shot 1100204014 (1.35MA, 5.8T). This was an I-mode shot with ELMs, some
of which were not induced by sawteeth. Attempt to reproduce this using
4--5MW of ICRF. Next insert ZCUR modulation from 0.9 to 1.4s. Choose a drive
frequency close to 100Hz, but not a harmonic of the sawtooth frequency.
Parameters: Period= 9, 10, or 11ms, ModMax= -.004m, ModMin=0.0m ,
trampup/down=.002 s
Adjust mod parameters as needed to maintain vertical stability and look
for ELM triggering/pacing. (2--5 shots)


Physics Operators Plans
Entered: Mar 1 2010 01:29:52:010PM
Author: Steve Wolfe
Physop plan and Engineering Setup for Tuesday, Mar 2, 2010
MP#593 "Vertical equilibrium shifts triggering ELMs"
and
MP#502 "HIREX_SR calibration"

Overnight ECDC in D2
gas and pressure: D2 at 2e-4 Torr
sweep: 44/45/103 cm
scan: 20/120 s

-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Cryopump required for all shots

Power systems as on: 1100209028

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid Enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gatevalves and shutters: ECE, VUV, HiREX Sr, B-spectrometer, Z-bolo

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes
ICRF(yes/no): Yes
LH(yes/no): no
Cryopump (yes/no): Yes

Vessel temperature: 35/35/35

Physop plan:

(See also SL Plan for MP#593)
H-mode section:
1. Start from 1100209028 (Ip=1MA, Bt=5.4T, nl04=1e20, 200Hz zcur mod)
Begin with ICRF as on 1100209028 (on at 0.6s, ramping to 3.3MW at 0.8)
then increase power. Presumably the boronization will be mostly gone,
so we won't get EDA. The transients at the H-L transitions may make
the modulation unstable, so we may need to back off further, or go on to
step 2. [3-4 shots]
2. Delay RF waveform relative to modulation, trying to have mod start
earlier in H-mode and maybe before the H-mode, hopefully providing some
ELM effect on impurities. [2-3 shots]
3. Reduce density to make the target even less EDA-ish [2-3 shots]
4. If the mod is making ELMs that seem to be doing something, take some
unmodulated control shots [0-4 shots]

I-mode section:
5. Load from 1091203015(1.2MA, 5.6T, ELMy I-mode). First, try to reproduce
the original behavior (no modulation). Then add modulation, as indicated in
Alcasim tests: Period= 9, 10, or 11ms ModMax= -.004m, ModMin=0.0m ,
trampup/down=.002 s
Tune to taste (or stability) avoiding harmonics of the sawtooth freq,
and look for ELM effects [2-5 shots]
6. Load from 1100204014(1.35MA, 5.8T, ELMy I-mode) and attempt to reproduce it.
Again, add modulation: Period= 9, 10, or 11ms, ModMax= -.004m, ModMin=0.0m ,
trampup/down=.002 s
and tweak as needed [2-5shots]

Sometime around 15:00 (or earlier if things are really uninteresting),
switch over to MP#502 (M. Reinke, "HIREX_SR calibration")

Load from 1100226015 (ohmic, 5.4T, 1MA, nl04-7e19). Give Matt a cell access.
Repeat shots, with cell accesses, until we run out of time or lose another
breaker.



Session Leader Summaries
Entered: Mar 2 2010 03:31:12:310PM
Author: Jerry Hughes
Session Leader summary for 1100302
MP593 "Vertical equilibrium shifts triggering ELMs"
SL: Jerry Hughes
PO: Steve Wolfe

Today we attempted to apply fast vertical jogs to ELM-free H-modes and
I-modes in an attempt to trigger ELMs. The technique used is largely
the same as that used on previous runs 1100202 and 1100209, but today
we went forward without a boronization, reasoning that stationary
H-modes would not be essential as targets for the vertical modulation.

200Hz Vertical displacements were used in 1MA, 5.4T H-modes, as was
done on shot 1100209028. In that shot, numerous discrete spikes in
D-alpha were observed, in apparent synchronization with the vertical
jogs. Qualitatively similar behavior was observed today, though the
D-alpha spikes were not as highly contrasting with the backgorund, and
from comparison of D-alpha views, one might conclude that the bursts
in D-alpha were due primarily to changes in the location of recycling
light, as the equilibrium becomes closer or farther away from double
null. Like on 1100209, these events did not correlate with any fast
modification to the plasma.

On the other hand, when we began to bring down the programmed density,
there were signs that we were doing something with the jogs. In
particular, on shot 012, from about 1 to 1.1s, there were several
D-alpha spikes with exponential falls, correlated with sudden drops in
the edge Te, as observed on GPC. These events tended to occur when the
plasma equilibrium was shifted up, or rising. They were not correlated
with sawtooth heat pulses, and in fact the edge dT/dt was generally
negative leading up to each event. They look like brief lapses in edge
confinement. Are they ELMs or brief H-L transitions?

We didn't get a very satisfactory control discharge without the
modulation because we were starting to get hit hard on the startup
with runaways. K limiter was taking a beating, and radiation was
getting to be out of control.

We still had problems with machine conditions in the second part of
the run, attempting to access I-mode. Mo radiation was just too
severe, we think, to achieve a substantial Pnet, and no sustainable
temperature pedestal was achieved in USN cases which were loaded from
very successful I-mode shots (1091203015, 1100204014). We did manage
to test the ZCUR modulation scheme in these configurations and found
that 100Hz modulations were easy to apply, with programmed ramp rates
of 2ms, and peak-to-peak amplitude of 4mm. The realized amplitude of
the oscillation was 6mm in the 1.2MA case, and 4mm in the 1.35MA
case. Perhaps there is more headroom to increase the oscillation.

At 15:00 I turned over the run, as planned, to Matt Reinke for
equally exciting Hirex Sr calibration shots.


Entered: Mar 2 2010 06:03:30:920PM
Author: Matt Reinke
Shots 025-032 were MP502 - HIREXSR Calibration (Thanks Jerry!)
The repeatability took more time to setup as the gas puff from 1100226 seemed to cause an upper x-point MARFE, leading to disruptions.
As per The Wolfe's suggestion, moved to a PWM of B-SIDE-LOWER at 1 psi, with at first 40% duty cycle (to small) and 70% (just about right).
029-032 were repeatable seeded discharges with 025 being the baseline unseeded. We were able to do a top 1/2, bot 1/2 cover of H-like crystal and got similar but cleaner results than 1100226.
We weren't able to do any vignetting tests on the He-like system since we overcorrected for the declination problem and spent the rest of few shots trying to get it centered and aligned.
The system should have good up/down alignment but the z-line is still very vignetted. We'll have to try and address this on Thursday by enclosure movements.

Physics Operator Summaries
Entered: Mar 2 2010 06:02:24:843PM
Author: Steve Wolfe
Physop summary for Tuesday, Mar 2, 2010
MP#593 Vertical equilibrium shifts for triggering ELMs 
SL: Hughes (shot#1-24)
MP#502 HIREX_SR calibration 
SL: Reinke (shot#25-32)

The vertical modulation experiment made it through essentially all 
of the planned cases, but not with notable success. The radiated
power was about equal to the input power for all but a couple of 
the high current USN shots, and ELMs were hard to come by. Despite
the high prad and apparently high Mo levels, the LSN cases based 
on 1100209028 looked pretty EDA-ish, although this changed when we
reduced the density, and ended up with very short, ugly, ELM-free
H-modes. There were a few promising looking events early in some RF
pulses that might be certifiable as ELMs, as noted in the SL_SUMMARY.
However, compared to the results from 1100209, the correlation with the
vertical modulation was not nearly as definitive. 

The Upper null cases, based on two I-mode shots from Dec and Feb, never
really developed into I-modes, despite the fact that the RF ran to 
over 5MW; except for shot#23, Prad kept pace with the input. The 
vertical modulation worked successfully on the upper null high current 
cases, but there was no sign of ELMs, which is not surprising considering 
the low Pnet's and lack of a temperature pedestal. These shots seem to
be a counter-example to the proposition that I-mode does not require 
a boronized machine. Note that the upper null cases were in segments 3 and
4. 

The startups in the first part of the run were based on the ones
I ran last week (1100224021) which had been fizzle-free, bounce-free,
and runaway-free for most of the day. However, this was not the case today. 
We had bad runaway problems starting early in the run, and got a fizzle on 
shot#7. I tried reducing the early OH1_VOLT programming (point at .05sec,
pivoting on the point at .035sec), but this was unsuccessful. Increasing
RCUR offset to 3000 and making EF4 more positive (-1280) were also 
unsuccessful. Note that the OH1_VOLT and IP traces in the active segments
(3 and 4) after shot#16 were also adjusted to avoid a lurch at segment switch
with the OH1_VOLT set to 150V (instead of 250V). 

Jerry turned the run over to Matt at ~15:00 as planned. Since I'd had 
no success getting rid of the runaways all day, I imported both segment#1 and
#2 from Matt's reference shot 1100226015. The startup was about as different
as possible, having very negative EF4(-1315) , RCUR offset=2000, BR_0=-.0005 instead of +.0005, and of course none of the voltage adjustments. 
The PG4 was at -.5 sec instead of -.3sec, and was 77msec instead of the 
50 to 60msec I had been using. Of course, the first shot with these settings 
ran with no runaways and no bounces. However, both came back later in the 
afternoon, though not nearly as bad as some of the earlier shots. I left this 
startup unchanged for the rest of the day (#25-32), with no fizzles. 

This part of the run had some difficulties getting started because Matt
was asking for rather low plenum pressures of Argon (0.5psi) which proved
difficult to set. Shots #26 and 27 disrupted, apparently due to excessive
argon. On shot#28 I suggested we put closer to 1psi argon in the plenum (we 
ended up with .8psi) and use modulation on the valve drive, adjusting
the duty factor to get the correct amount. This seemed easier to 
setup than using the dpcs_piezo_chopper output_pro, which was created
earlier to deal with this sort of thing. I used a 20msec period, 
and on #28 set a 40% duty factor with 1msec ramps, with ModMax=100.
This seemed to work but didn't give enough argon, and we increased to
70% on #29-32. All of these shots ran full length. There were cell accesses
before every shot for this part of the run, and some progress was made
on aligning the spectrometers. They believe that the "hyrdogen-like"
system which is to be used for the runs on Thursday and Friday to look at
Calcium, is now correctly setup, but more work needs to be done
to the helium-like system. See Matt's SL_SUMMARY for details.

Scorecard: 
----------
                    Tests/No power shots    0
                    Duds                    0
                    Fizzles (or < 50msec)   4
                    Plasmas                28 (2 current rise disruptions)
                    =================      ==
                    Shots                  32     



Session Leader Comments
Mar 2 2010 09:16:28:653AM1100302001Jerry HughesFirst shot is a reload of 1100209028, which had an EDA H-mode with itty bitty
ELMs, synced to a 200Hz ZCUR modulation.
5.4T, 1MA. nl04=1e20. cryopumped.
We will run it and see what we get. If Amanda requests a Btor tweak to optimize
ECE positions, we will implement that on subsequent shots.

Result:
I thought I saw the WIDE2 view rotate during the shot. Probably my imagination.
Reasonable shot with what looks like an EDA H-mode. Starting at 0.9s,
we see some hash on D-alpha, though not as large as on the target shot.
RF is reacting to the jogs.
Lost E-port. Yijun will try to improve tune on next shot.
Also, fast EFIT needs to be re-run at a shorter period in order to make sense
of the modulation.
Mar 2 2010 09:31:34:217AM1100302002Jerry HughesShot 2:

This was a retry of shot 1 with more power.

RF behavior was a bit worse, with faults on E and J during the initial H-mode
phase.
There are some H-mode phases with up to 3MW of ICRF, some signs of ELMs but
no real standout signals.
Several H-modes, density dropping with each successive one.

Next: RF guys will try to improve the tune.
Mar 2 2010 10:39:39:873AM1100302003Jerry HughesShot 3:

Got close to the RF demand on that one. Plasma is radiating like crazy.
There are large bursts in the D-alpha early, before the modulation, not seen
on the RF traces. After the modulation, you see smaller more discrete D-alpha
spikes, and fuzz on the RF.
Radiation being what it is, the edge is much colder than on 1100209028, so
maybe it's no surprise we see smaller "ELM" activity.

t_mod,start - t_L-H = 0.18s

Next: Repeat, but with modulation starting at 0.85s rather than 0.9s.


Mar 2 2010 10:38:51:687AM1100302004Jerry HughesShot 4:

Very similar to shot 3. Modulation begins at 0.85s. t=0.85 to 0.90s is the
period of peak temp, neuts in this shot. There are also frequent D-alpha
spikes in there.
Radiation gets high by 1s and kills the confinement.

t_mod,start - t_L-H = 0.141s
Mar 2 2010 10:36:49:230AM1100302005Jerry HughesShot 5:

Started the modulation at 0.8s. Looks like 200Hz ELM activity on the D-alpha,
at least for the first ~100ms of the mod.
Same confinement degradation by 1s.
D-port didn't go, so total RF was at the 2.5MW level.

t_mod,start - t_L-H = 0.047s

Mar 2 2010 10:51:10:887AM1100302006Jerry HughesShot 6:

Starting modulation at 0.75s.

Radiation rise not really affected. A very brief period of ELM-like activity
on the fast D-alpha. Longer period of spikes on the slower D-alpha signal, all
the way out to 1.4s and beyond. After the modulation ends, the bursts seem larger
and broader.

t_mod,start - t_L-H = 0.06s

Earl sees the rotation on the TV screen too. We speculate that it is the
magnetic field acting on the CRT.

Next: move modulation to start at 0.7s
Mar 2 2010 10:40:16:813AM1100302007Jerry HughesShot 7:

No plasma.


Mar 2 2010 11:24:32:880AM1100302008Jerry HughesShot 8:

Got L-H at 0.7s, almost contemporaneous with the onset of ZCUR modulation.
Looking carefully, I think what is happening is broad bursts in the HA_2_BRIGHT
signal (looking at upper part of plasma) are associated with the phases
with ZCUR shifted up, and that the faster spikes in MCP_VIS_SIG1 (collimated near
midplane) are associated with the downward strokes. So what we're seeing right
now may just be recycling light moving about as we jog the topology.


Mar 2 2010 11:27:12:350AM1100302009Jerry HughesShot 9:

Lost density feedback, got a locked mode.

Will try again.




Mar 2 2010 11:34:15:297AM1100302010Jerry Hughes
Shot 10:

No plasma
Mar 2 2010 11:59:57:200AM1100302011Jerry HughesShot 11:

Lowered target nl04. Got a lot of ELM-free H-modes -- not worth counting
them all -- gradually decreasing in density. Within the first couple of H-modes
there is activity on the D-alpha that seems correlated with the ZCUR shifts,
although, it is not obviously ELMy.
Mar 2 2010 12:43:51:597PM1100302012Jerry HughesShot 12:

Lower nl04. . . . And it made it through.

Similar to shot 11. But there is an interesting phase between 1.0 and 1.1s
where I see spikes in D-alpha, with exponential decays, accompanying sudden
drops in the edge GPC. The events are happening when Te,GPC8~800eV, and
predominately when ZCUR is rising or near its local maximum.

In the period just before the "ELM", Te,ped is ~500eV, ne,ped is ~8e19.
(e.g. t=1.06025s)
Afterwards there is significant pedestal relaxation. One wonders if they are
not just a flavor of H-L transition.

Next: Try this shot without modulation.
Mar 2 2010 12:26:52:640PM1100302013Jerry HughesShot 13:

Attempt to repeat the low density case in 12 without ZCUR modulation.
Radiation is very high on this shot. Not enough H-mode duration.


Mar 2 2010 12:27:25:560PM1100302014Jerry HughesShot 14:

No plasma

Mar 2 2010 12:54:56:717PM1100302015Jerry HughesShot 15.

Similar to 14.

Next: Move on to I-mode cases.
Mar 2 2010 01:15:17:810PM1100302016Jerry HughesShot 16:

Reloaded shot 1091203015 (5.7T, 1.2MA), which had an I-mode.

Got the desired shot, complete with 5.2MW of ICRF. No I-mode, unfortunately.
Prad is a bit higher than it was in the target.

The target went into I-mode following a sawtooth crash with deltaT~1.8keV.
Maybe the size of the sawteeth matters.


Next: try some seeding with Ne. Can't hurt (?)
Mar 2 2010 01:17:13:500PM1100302017Jerry HughesShot 17:

No plasma.

Matt observes that the 2pi foil is saturated on the last few shots.
Cell access to correct.

Mar 2 2010 01:29:22:260PM1100302018Jerry HughesShot 18:

Disastrous startup. Disrupts at 0.3s.

Mar 2 2010 01:53:32:900PM1100302019Jerry HughesShot 19:

This shot went through. RF power is there, and so is the high Prad. No
obvious I-mode, but Arturo notes a temporary decrease in broadband turbulence
in the 75GHz reflectometer on this shot and on 16, right after RF comes up,
correlated with increased edge Te. Maybe if the radiation was less severe,
we'd be there.

Next shot: Let's try shaking, starting at 0.70s. At least see whether this
configuration can tolerate the jogs.
Mar 2 2010 01:58:18:340PM1100302020Jerry HughesShot 20.

Runaways and early disruption.

Mar 2 2010 02:18:25:270PM1100302021Jerry HughesShot 21.

I-mode attempt with modulation beginning at 0.7s. The ZMAGX trace looks very
good. J-port is lost shortly after the modulation starts.

Next shot: retry with full power.
Mar 2 2010 02:40:19:420PM1100302022Jerry HughesShot 22:

Full power in the I-mode target, with modulation.

Successful modulation at ~100Hz.
Mar 2 2010 02:56:49:863PM1100302023Jerry HughesShot 23

Recalled a nice I-mode trophy. Prad is down, but but still no I-mode formation.
1.35MA, 5.8T. It seems that I-mode is definitely not a cure for high Z disease.

Next: try to modulate this condition.
Mar 2 2010 03:04:19:950PM1100302024Jerry Hughes
Shot 24:

Repeat the 1.35MA USN shot with modulation.

Lost J-port early, as we did on shot 21.

Modulation was successful, with 4mm of oscillation.

We've exhausted the run plan, and it's 3pm, so over to Matthew Logan.
Mar 2 2010 03:08:01:563PM1100302025Matt ReinkeSwitchover to MP502 HIREXSR calibration.
Load 1100226015 but change to 0.4-0.5 sec Ar puff to get baseline.
Before the shot, gave He-like crystal a large change in declination.
No masks installed.
IMPINJ of CaF2 at 0.7 sec.
Mar 2 2010 03:42:50:180PM1100302026Matt ReinkeRepeat 025 but w/ 0.4-1.4 sec Ar puff
No masks

This disrupts early, loses density control. Looks like too much Ar. We're at 0.7 psi compared 0.5 last Friday.
Mar 2 2010 03:58:33:010PM1100302027Matt ReinkeRepeat w/ Ar back down at 0.6 psi
No masks

Disrupted early but made it a bit later. Same gas pressure is not working the same as it did Friday. Looks like I get some sort of MARFE at the upper xpoint (WIDE2) and loose density control
Mar 2 2010 04:00:48:030PM1100302028Matt ReinkeRepeat but with 0.8 psi w/ 40% duty cycle (didn't know we could do that).
No masks.
Mar 2 2010 04:24:27:993PM1100302029Matt ReinkeRepeat w/ 70% duty cycle on puff
No masks

Much better Ar seeded shot.
Mar 2 2010 04:24:53:027PM1100302030Matt ReinkeRepeat
Bot 1/2 H-like Ar mask
Mar 2 2010 04:40:59:060PM1100302031Matt ReinkeRepeat
1/2 mask on top of H-like
Mar 2 2010 04:55:23:123PM1100302032Matt ReinkeRepeat
remove mask on H-like

Physics Operator Comments
Mar 2 2010 07:46:26:597AM1100302001Steve Wolfe
DPCS Setup for MP#593
Load from 1100209028 
Import seg1 from 1100224021, with modified RCUR offset, IC_EF4U from 
  last week which seemed to have better runaway suppression
 Change pg4 puff from [-.525,-.5] to [-.350,-.3] for cryopump
Seg2:
 Note irregular modulation on zcur is a consequence of 1msec snapgrid with
  odd period, leave it alone, since we are trying to reproduce the results
  of 1100209028 (200Hz modulation, MaxMod=.004).
 Zero out the (unused) ssep waveforms, just so the PhysAout scope will
  readout directly
 Note there is a little jog in rcur at 1.43 to 1.5sec; don't know what it's 
  for, must have been a piggyback experiment. Leave it for now, ask Jerry
  when he gets in.
Import seg3 from seg2 of 1091203015 (1.2MA, 5.6T, USN) to be used for
  step#5. 
Import seg4 from seg2 of 1100204014 (1.3MA, 5.8T, USN) to be used for 
  step#6. Note that the title says it's 1.2MA and it's actually 1.3MA
   Remember to increase TF current limit when/if we get to this step.
Load at  2-Mar-2010 07:32:27.00 (be safe while I check the segs from
those two shots)

In a separate konsole, unset pcs_scratch and bring up pcs /safe
 Verify seg2 was active on 1091203015 and on 1100204014.
quit pcs /safe session

Seg3: Change PG1 puff in seg3 from [.55,.75] to [.3,.375]
 Do a build_segment
Seg2: Note that there is a feedforward puff on pg3 and the NL04 gains
 are [8,0,0]. This is not ideal for cryopump, but it worked before and
 we want to reproduce the shot, so leave it. 

Change seg titles, load it up.
Load at  2-Mar-2010 07:46:00.00



Mar 2 2010 09:09:36:143AM1100302001Steve Wolfe
Shot#1: plasma to 1.35sec, no significant ELMs
EDA-ish H-mode until 1.18sec, E faults early, others trip 
at 1.18 and then recover, but plasma doesn't. 

Next: repeat 


Mar 2 2010 09:28:57:917AM1100302002Steve Wolfe
Shot#2: Drop tfcurrent from 150000 to 148500
No change to startup, probably should have dropped the gas
plasma into rampdown, several H-modes not steady. 
Some elms but not as obvious as on 1100209028. 
RF less happy than on shot#1. 
Excursions on zcur near the H-L-H transitions (six H-mode), several 
almost lose it. 

Next: RF trying to get better match


Mar 2 2010 09:43:22:683AM1100302003Steve Wolfe
Shot#3:  RF trying to get better match
No dpcs changes. 
plasma full length, runaways early (so much for the startup)
ELMs during three H-modes, first one mostly eda-like, 
but lots of prad, Prf=3.5MW, Prad(2pi foil)=3.3MW

Next: Move modulation earlier instead of delaying RF

Mar 2 2010 09:56:32:310AM1100302004Steve Wolfe
Shot#4: Move modulation earlier instead of delaying RF
Modstart=.85, period=.005, duration=.551, 
ramps=.002, max=.004, min=0., duty=.5
Do this to both wire 2 and 3, since paste screws up grid
No startup changes, see if runaways get worse
Load at  2-Mar-2010 09:47:06.00
plasma full length, early runaway burst dumps at .118sec
Prad similar, so is RF, so is halpha trace, which seems to have some strong
activity before the modulation starts. 

Next: move mod earlier

Mar 2 2010 10:13:20:733AM1100302005Steve Wolfe
Shot#5: move mod start to .80, duration to .601
Leave other parameters the same.
Load at  2-Mar-2010 09:58:08.00

plasma into rampdown, disrupts at 1.67sec
Prf down a little? Neuts down by a factor of two from 4, 
2pi is below 3MW. D never made it through the initial round
of faulting. Things that look sort of like ELMs start with 
modulation, but peter out, and there are still some events
after modulation ends between 1.4 and 1.45sec

Some early runaways again. 

Next: move modulation start to .75sec

Mar 2 2010 10:29:26:360AM1100302006Steve Wolfe
Shot#6: move mod start to .75, duration to .651
Load at  2-Mar-2010 10:14:31.00
Start fast efit at 0.70sec
No startup changes. 

plasma to 1.65sec, similar to #5
Got all the RF's, still only 3MW. and still radiating 3MW.
Still seeing ELM-like things through EOF (after mod is off!)
runaways better. 

Next: Modstart to .70sec

Mar 2 2010 10:40:37:093AM1100302007Steve Wolfe
Shot#7: move mod start to .70, duration to .701
Load at  2-Mar-2010 10:30:38.00
fast efit start to .65sec
Move oh2 reverse current limit to -30,30; it was close to the rail on #6. 

Fizzle. looks like it moved in, slow burnout. 
Next: drop pg4 a smidge

Mar 2 2010 10:54:37:080AM1100302008Steve Wolfe
Shot#8: pg4 from 50 to 47msec
Changes on shot#7:
move mod start to .70, duration to .701
Load at  2-Mar-2010 10:30:38.00
fast efit start to .65sec
Move oh2 reverse current limit to -30,30; it was close to the rail on #6. 
change fast_efit burst_steps from 1750 to 2000

plasma full length, bad runaways early, multiple H-modes, 
possibly more elmy things. Runaways still seem to get started around .05sec,
no sign of bounces. 

Next: drop target density to 0.8e20


Mar 2 2010 11:27:26:383AM1100302009Steve Wolfe
Shot#9:  drop target density to 0.8e20, drop pg3 feedforward 
Decrease seg1 oh1_volt at [.05,.1] sec from 250 to 200V; no 
change to seg2 value, which is at 250, so there may be a lurch at seg switch.
TORVAC RSview problem, calling Joe &/or Yuri
Need a cell access to fix TORVAC

Time in RECOOL 26:45
disrupts at .95sec. no H-mode at 3MW RF. 
Looks like a locked mode around 0.7sec
TCI feedback was screwed up, bouncing rail to rail and losing
fringes. Early density was 3e19 at .4sec, that's probably where it
got into trouble.

Next: repeat, with TCI hopefully


Mar 2 2010 11:38:48:550AM1100302010Steve Wolfe
Shot#10: repeat with target density to 0.8e20, drop pg3 feedforward 
On#9, the jump in oh1 voltage at seg switch wasn't serious, not clear
if reduction in runaways was related to lower voltage or not. 

Jim says TCI is "better than it was".
Runaway early disruption, big injection at .041sec, 100ka
in trouble earlier, CIII light showing spikes before 20msec. 
xrays seem to start around 0.30sec

Next: Blame it on a flake and try again


Mar 2 2010 11:51:17:363AM1100302011Steve Wolfe
Shot#11: repeat with target density to 0.8e20, drop pg3 feedforward 

plasma into rampdown 1.62sec, lots of short ugly h-modes. There are 
some neuts, 3 to 4e13. Just over 3MW RF, 2pi foil is similar

Next: nl04 down to 6e19

Mar 2 2010 12:09:27:883PM1100302012Steve Wolfe
Shot#12:  nl04 down to 6e19, pg3 decrease again
NL04 PID gain from [8,0,0] to [4,8,1.5]
Plasma to 1.6sec, huge runaways. So much for dropping the oh1 by 50V. 
Ugly short H-modes, I think. Nothing looks like ELMs to me, 
but Jerry has the gogs on. 
Prf 3.5MW, Prad about the same. 

Next: tweak rampdown rcur and clearin to get rid of disruption 
Turn off modulation and see what changes



Mar 2 2010 12:20:45:757PM1100302013Steve Wolfe
Shot#13:  tweak rampdown rcur and clearin to get rid of disruption
RCUR flat instead of ramping in, clearin ramping from +.003 to -.003 
Turn off modulation and see what changes
Mod amp to 0, period to .1s
No startup change, will runaways get better or worse? 

Runaways worse, plasma disrupts at 1.43sec, before my rampdown 
changes. If there's an H-mode it ends by 0.9sec. 
Need to get rid of the runaways. There's actually synch rad around 0.5sec.
Runaways are building up from .04sec, 

Next: program RCUR in by 2cm, ef4 10amps more positive


Mar 2 2010 12:32:18:770PM1100302014Steve Wolfe
Shot#14:  program RCUR in by 2cm,from [.62,.64] to [.61,.62] at [.02,.05]sec
 ef4 from -1290 to -1280
No seg2 changes

fizzled. That didn't work.
Ratiomatic was off, but it looks like this one went up and in
after a bounce at .022sec

Next: Put rcur waveform back, increase offset from 2500 to 3000



Mar 2 2010 12:45:47:677PM1100302015Steve Wolfe
Shot#15:   Put rcur waveform back, increase rcur offset from 2500 to 3000
leave ef4 at -1280, pg4 from 47 to 50msec

Another seriously bad runaway shot, disrupts at 1.5sec
Again, no bounce or other obvious position problem. 
I can try raising the pg4 more, or dropping the oh1_volt more, or both.

Next: go on to the I-mode cases, 
and try both of the above
 


Mar 2 2010 01:04:24:810PM1100302016Steve Wolfe
Shot#16: go on to the I-mode case, turn off seg2, turn on seg3
This one is at 1.2MA, 8e19, TF=-158400
PG4 from 50 to 55msec
Drop OH1_volt at [.05,.1] from 200V to 150V
still no change in seg3 oh1_volt
No modulation yet

Plasma full length, still lots of runaways, but no synch rad 
Startup looks like it almost choked. 
No ELMs
According to BTOR we got -5.74T, -159.8ka on TF rog
Current is down at seg switch (470kA), and there is a big step in
OH1 voltage. 

Next: decrease Ip program at .1sec
add 200msec of neon




Mar 2 2010 01:12:07:070PM1100302017Steve Wolfe
Shot#17: decrease Ip program from 600 to 500 at .1sec
Decrease seg3 oh1_volt from 250 to 150 at start of seg4
(try to smooth out the seg switch, not that the runaways are gone)
add 200msec of 1psi neon starting from .55sec, to make it like
the 1091203015 target.

fizzle.
Next: pg4 back down to 50msec




Mar 2 2010 01:36:48:863PM1100302018Steve Wolfe
Shot#18: pg4 back down to 50msec
BR_0 from .0005 to .0003 (#17 moved up before it crashed)
Changes from #17:
decrease Ip program from 600 to 500 at .1sec
Decrease seg3 oh1_volt from 250 to 150 at start of seg4
(try to smooth out the seg switch, not that the runaways are gone)
add 200msec of 0.8psi neon starting from .55sec, to make it like
the 1091203015 target.

Runaway disruption early .29sec, oh1 crowbars after the disruption.
Runaways start very early, but no bounces or position problems.
There's also a big marfe from .18sec or so on. Zave is over 4.


Next: PG4 from 50 to 55msec




Mar 2 2010 01:43:54:967PM1100302019Steve Wolfe
Shot#19: pg4 back up to 55msec
BR_0 from .0005 to .0003 (#17 moved up before it crashed)
Changes from #17:
decrease Ip program from 600 to 500 at .1sec
Decrease seg3 oh1_volt from 250 to 150 at start of seg4
(try to smooth out the seg switch, not that the runaways are gone)
add 200msec of 0.8psi neon starting from .55sec, to make it like
the 1091203015 target.

plasma full length, runaways reduced but still there.
decent neuts. 

Next: try turning on modulation



Mar 2 2010 01:58:03:030PM1100302020Steve Wolfe
Shot#20: turning on modulation from .7 to 1.4sec
period=.01, .002 ramps, ModMax=-.004, ModMin=0

Another runaway-dominated disruption around 0.2sec
very similar to 18, except the self-powered circuit didn't fire.


Next: raise pg4 again


Mar 2 2010 02:17:08:520PM1100302021Steve Wolfe
Shot#21: pg4 from 55 to 60msec, move start of pg3 puff to -.020sec
Zcur modulation from .7 to 1.4sec
period=.01, .002 ramps, ModMax=-.004, ModMin=0
plasma full length, some runaways, not so bad as previous.
Got modulation, did not get ELMs, RF lost at least one xmitter
Only 2.5MW after .77sec (J dropped out)

Getting about 5 to 6mm zmagx modulation. 
Next: repeat, hope for less runaways, more rf


Mar 2 2010 02:51:18:043PM1100302023Steve Wolfe
Shot#23:  move seg1 pg3 puff 5msec earlier (-.025)
Move on to case 6 (1.3MA, 1e20, 5.8T): Seg3 off, seg4 on (from 1100204014)
Drop Ip at 0.1sec from 600 to 500ka at 0.1sec, drop OH1_volt to 150V
Disable B-side lower (no neon), Raise TF current to 170kA
No modulation

Still humongous runaways. D didn't go, got 3.8MW, no elms
Not a good I-mode, radiation still too high, but down to 2.5MW
on prad_main

Next: repeat with modulation, hope the RF happens




Mar 2 2010 03:03:45:090PM1100302024Steve Wolfe
Shot#24:  repeat with modulation, hope the RF happens
Modmax=-.004m, period=.01s, ramps=.002s
move pg3 puff to -.030sec, hope the xrays stop happening

plasma to 1.12sec, runaways. Prad growing after 1sec, maybe 
melting something? J drops out after .77sec, D and E survive
Modulation ran as programmed, doesn't seem to go unstable
Gets about 4mm, which is what we asked for. Might take more,
although the chopper current is bouncing off zero.

Next: Go to MP#502 experiment






Mar 2 2010 03:24:36:330PM1100302025Steve Wolfe
Shot#25: MP#502
Import seg2 from 1100226015
Seg4 off, seg2 on
B-side lower filled to 0.5psi Argon
Change pg1 puff from [.4,1.4] to [.4,.5]sec
Import seg1 from 1100226015 as well, since this one isn't working well.
This one has pg4=75msec at -.5sec, rcur offset=2000, BR_0=-.0005, EF4=-1315
About as different as can get, but it ran on Friday so try it.

plasma full length, NO RUNAWAYS! None! And no bounce either. 
BR_0 looks too negative, but I'm not touching it.
nl04=7e19, got argon puff from .4 to .5sec, .7psi

Next: cell access and repeat



Mar 2 2010 03:44:02:887PM1100302026Steve Wolfe
Shot#26: cell access
PG1 puff from .4 to 1.0sec (mistake, SL asked for 1.4sec)

Runaways are back, small bounce at 12msec. disrupts at 1.05sec. 
prad is big, looks like too much argon, but maybe something else.
Pump out bside-lower, refill with 0.5psi argon, and change puff to go to 
1.4sec


Mar 2 2010 03:54:47:600PM1100302027Steve Wolfe
Shot#27: cell access
PG1 puff from .4 to 1.4sec, bside lower re-filled to 0.58psi argon
No startup change this time, since it disrupted maybe 77msec is enough

plasma disrupts at 1.3sec, no runaways. 
rising prad

Next: Decrease bside-lower pressure to 0.4psi




Mar 2 2010 03:57:46:950PM1100302027Steve Wolfe
Shot#27: cell access
PG1 puff from .4 to 1.4sec, bside lower re-filled to 0.58psi argon
No startup change this time, since it disrupted maybe 77msec is enough

plasma disrupts at 1.3sec, no runaways. 
rising prad

Next: Fill bside-lower to 0.8psi and use duty factor and modulation 
to get 40% of that




Mar 2 2010 04:10:57:183PM1100302028Steve Wolfe
Shot#28: Fill bside-lower to 0.8psi and use duty factor and modulation 
to get 40% of that
Modulate from .4 at .02sec period, duration=1.001
ramps=.001, ModMax=100, ModMin=0, duty=0.4
on top of zero base on pg1

plasma full length. No runaways, Got some argon, 
Matt says not enough. 

Next: increase duty to 0.7


Mar 2 2010 04:23:49:963PM1100302029Steve Wolfe
Shot#29:  increase duty to 0.7, keeping period=0.02
plasma full length, no runaways. Prad rises to ~700kW

Matt seems happy with the argon level, so leave it alone 
until he changes his mind. 

Next: repeat after another cell access


Mar 2 2010 04:38:56:823PM1100302030Steve Wolfe
Shot#30:  repeat after another cell access
resisting temptation to drop the fill

plasma full length, no runaways. 2pi bolo looks similar.
Next: repeat after cell access


Mar 2 2010 04:53:19:920PM1100302031Steve Wolfe
Shot#31:  repeat after another cell access
plasma full length, with runaways (5e14)
Couple of bounces in startup. 
Ratiomatic was off again, seems to fail every shot now, probably on
cryo regens, and the auto-restart is non-functional. 

Next: repeat after cell access



Mar 2 2010 05:06:53:200PM1100302032Steve Wolfe
Shot#32:  repeat after another cell access
plasma full length, some runaways (2e14)

END OF RUN
Boronization to start after a (hopefully brief) cell access



Engineering Operator Comments
ShotTimeTypeStatusComment
108:57:43:257AMPlasmaOk
209:15:06:137AMPlasmaOk
309:31:56:030AMPlasmaOk
409:48:40:330AMPlasmaOk
510:05:57:930AMPlasmaOk
610:19:16:180AMPlasmaOk
710:35:14:010AMPlasmaOk
810:48:05:087AMPlasmaOk
911:17:58:560AMPlasmaOk
1011:31:32:700AMPlasmaOk
1111:44:31:370AMPlasmaOk
1211:58:13:370AMPlasmaOk
1312:11:56:683PMPlasmaOk
1412:25:11:450PMPlasmaOk
1512:38:25:793PMPlasmaOk
1612:51:43:960PMPlasmaOk
1701:09:15:807PMPlasmaOk
1801:25:00:647PMPlasmaBadOH1 self powered
1901:39:24:867PMPlasmaOk
2001:52:37:210PMPlasmaOk
2102:05:53:070PMPlasmaOk
2202:19:22:740PMPlasmaOk
2302:37:00:370PMPlasmaOk
2402:54:52:593PMPlasmaOk
2503:16:54:573PMPlasmaOk
2603:32:59:263PMPlasmaOk
2703:50:17:893PMPlasmaOk
2804:03:50:987PMPlasmaOk
2904:17:02:563PMPlasmaOk
3004:32:56:940PMPlasmaOk
3104:46:57:973PMPlasmaOk
3205:01:48:067PMPlasmaOk

System Availability
Mar 2 2010 08:57:05:427AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (diode+foil), AXA, AXJ, WB3AX, WB4AX, LEDGE-AX working fine. MID-FOILS working fine. The LEDGE/DIV foils still need calibrations appliedAug 27 2009 09:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationyes Nov 13 2009 06:37AM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesOperationalNov 09 2009 09:12AM (irby)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationyesoperational, but turned offNov 03 2009 04:59PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnoin test mode onlyNov 03 2009 05:01PM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCyes Nov 09 2009 09:13AM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll channels working and calibrated.Feb 02 2010 09:56AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Controller repaired.Aug 23 2009 10:36PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Oct 27 2009 10:39AM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesoperational at 80 MHzJul 21 2009 04:49PM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesantenna and FFT operationalJul 21 2009 04:49PM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesavailable at 80 MHz and [0,pi,0,pi] phasingSep 04 2009 10:01AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-OffyesRequires some advance notice for laser start-upOct 16 2009 12:46PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data. WB1-LY not attached.Aug 27 2009 09:10AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesOperating normallyAug 27 2009 09:10AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Recalibrated 7/27/09.Jul 28 2009 04:22PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesPower back on morning of 11/09 before runNov 09 2009 09:10AM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesOperational.Nov 12 2009 02:36PM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,ennever,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Nov 13 2009 06:38AM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesSince 1100120000 the system is operational except for channel 110 which is not installedJan 20 2010 09:17AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker back in operation before 11/09 runNov 09 2009 09:11AM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes2 lasers working. 15 spatial channels operational. Calibrated Oct 13 2009 07:49PM (yma)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgeyesOperational, and calibrated.Oct 11 2009 03:01PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyesOperating normallyAug 27 2009 09:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke