Alcator C-Mod Run 1100317 Information

Back to runs

Miniproposals
Miniproposal:535a
Date Filed: 3/5/2008
Title:Rotation inversion vs density and current, in limited and diverted L-mode plasmas
First Author:Basil Duval
Session Leader:Basil Duval (shots 1-33)

Operators
Session leader(s):Basil Duval
Physics operator(s):Jim Irby
Engineering operator(s):Bill Cochran,Bill Byford,Ed Fitzgerald

Engineering Operator Run Comment
automatically entered by signon - please replace with real comment

Session Leader Plans
Entered: Mar 16 2010 05:03:12:600PM
Author: Basil Duval
Rotation reversal experiments

Low density- Suggest- ECDC He to prepare walls for low density operation

Continue #535 with #535a (previous experiments 108050201x)

Take shape from1091216029/30- Most recent example (LSN- no direct Cryo effect available)

Goal 1- Observe rotation reversal
- take density to below 0.9e20 and density ramp- (stay at 5T)
- When we get reversal, repeat 2x to get reproducibility
- Can we go up through reversal and back down using cryo-pump- Should we try USN ?
- repeat at 3T (keep qedge the same)- may need slightly lower Ne (0.7?)

Goal 2- Can we do this with limited discharge
- Move above config until CLEARLY limited- try to keep final shape the same
- Try and get the density down- I assume wall interaction will be problematic
- explore as above this configuration

Goal 3- Transition limited-diverted
- Ideally go from limited configuration with Ne below threshold-> diverted
- If not, do the same with Ne above threshold
- Try to take diverted below threshold and move onto limiter
- If not, do the same with Ne above threshold

Goal 4- q scaling
- Take Goal 1 curve and repeat with qedge 3.5, 4, 5 (Ip scan c/f TCV results)

############# Wished for diags
- CXRS (not available)- Pity-
- Edge rotation measurements (really interesting for diverted/limited
- X-ray sawteeth characteristics for all shots
- MhD characteristics for all shots
- All available bulk and edge turbulence measurements (long wavelength on PCI please)

- bpd, CMOD control room, 3/16/2010

Physics Operators Plans
Entered: Mar 17 2010 05:13:31:627PM
Author: Jim Irby
-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Power systems as on: 1091216030

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gatevalves and shutters: ECE, VUV, HiREX Sr, Z-bolo

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes
ICRF(yes/no): NO
LH(yes/no): no
Cryopump (yes/no): YES

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters
------------------------------
gas and pressure: Helium at 5e-5 Torr
sweep: 44/45/103 cm
scan: 20/120 s

Session Leader Summaries
Entered: Mar 17 2010 05:40:42:623PM
Author: Basil Duval
Summary of day

The goal of today's experiments was to check the toroidal reversal with limited and diverted configurations and to attempt to move between the configurations to observe changes

1) Reversal obtained for diverted configurations again- Shown to be reproducible
2) Reversal not really seen for limited configuration- This is probably due to the problem in achieving a low plasma density (see below)
3) Change from Counter -> Co seen between Limited and diverted configurations
4) qscan 3,3.6,4,5 confirmed scaling with plasma current. Reversed transition observed at q=3.6 operated by allowing the plasma density to drop after the initial part of the discharge-
5) Other experiments in the run plan were not attempted due to a lack of run time and most of the above experiments were curtailed in an attempt to cover the main questions within the allotted time.

Comments

Main problem was achieving low densities- Over-low density early in discharge resulted in locked modes with negligible plasma rotation (as would be expected)-
For diverted discharges we lost a LOT of the discharges with disruptions and/or locked modes- This was exacerbated by the changing machine conditioning that made it necessary to inject more prefill early in the discharges as the day progressed. Not only were many discharges lost due to these changes, but the increased early density required made the lower densities required by the limited configurations impossible and lower densities required by lower plasma current extremely tricky-

From the diagnostic viewpoint, it was necessary to compensate for a low drift in the spectrometer (Ar-senior) by performing several dedicated locked mode discharges that again interrupted the "shot flow"

Suggestions

Clearly we have observed the desired effect but were not able to reproduce all the effects that would confirm this conclusion because of the time it would take to fine-tune the plasma density and breakdown scenarios. The Bphi scan or Ip scan question remains unanswered and a low density diverted configuration was not achieved- The absence of CX measurements mean that only the core rotation was measured (as known before the experiments but a pity in any case) means that the CMOD results fall quite a bit short of what could be possible on CMOD, but PCI data was taken. (This is not yet available on TCV and could answer some of the outstanding questions)

In conclusion- All the data we finally obtained supports the previous conclusion that the toroidal velocity reversal shows all the signs of that reported from TCV- CMOD has the capacity to take this further with Bphi/IP scans and a wider range of edge diagnostics (but this would require CX measurements to obtain a complete rotation profile)- It would IMHO be extremely interesting to extend these measurements to provide further indications to the theoretical community on the parametric dependence of this effect- It would be useful to assess schemes to improve the machine conditioning and perhaps improve if possible the error field correction to avoid the early gas injection that made today's experiments so challenging.

A BIG thank you to all the people around that made CMOD run smoothly and to the diagnosticians who have only just commenced their toil-

_basil-

Physics Operator Summaries
Entered: Mar 17 2010 05:37:48:717PM
Author: Jim Irby
A combination of injections and low density locked modes caused a few early disruptions today. The early locked modes appeared around 400 ms when the density dropped dramatically. We spend a few shots filling in the "hole" using a large pg3 puff. The puff also cured the runaway problem Physop errors also lost us some shots (turning on wrong segment, not moving crowbar times, for example). When we started getting reliable plasmas we had to work to decrease the early density so that the planned density ramps could be done. Later in the run we spent several shots going from diverted to hard inner wall limited. Density rise from wall fueling was no issue after the first limited discharge. On shot 26 we went from hard limited to diverted at 0.8 s; an interesting discharge.

There were no power system problems today. We lost some data (Halpha, CIII) because of a CAMAC problem.

fizzle 01,27
plasma 02-26, 28-33

Session Leader Comments
Mar 17 2010 09:21:18:437AM1100317001Basil DuvalPre: Get repeat shot based on shape #1091216029 (breakdown full field- Bob's startup from yesterday)
Ar requested for the X-ray spectrometer
No density ramp requested- We're looking to get diagnostics and see what shape
we eventually get-

Post: BLIP- like being home-
Mar 17 2010 09:30:15:800AM1100317002Basil DuvalPre: Locked more #30 from yesterday, to calibrate X-ray spectrometer
Post: OK-
Mar 17 2010 09:47:09:057AM1100317003Basil DuvalPre: Shape from 1100317030- q 4->3.1, Ne ramp 0.7->1.3e20 during flat top
check Argon
Diagnostics
Post: Density ramp too fast and current ramp too slow- some data on Crystal- Good start
Mar 17 2010 10:04:27:530AM1100317004Basil DuvalPre: Repeat- Faster Ip ramp, target Ne ramp 0.7->1e20
Post: OK- Reversal !
However- Ne ramp started @0.9s and was really fast !
Mar 17 2010 10:18:17:177AM1100317005Basil DuvalPre: Repeat with ne ramp from 0.6->1.6 sec 0.6->0.7 in nl_04 units
Post: OK- Worked again- transition Co-> Counter occurs at nl_04 ~0.65
Mar 17 2010 10:29:54:480AM1100317006Basil DuvalPre: Repeat - prove reproducibility
Post: OK- got slower transition, but it was there
Mar 17 2010 10:49:45:050AM1100317007Basil DuvalPre: Faster gas ramp up to 1s, then gas cut to attempt reverse transition
Post: OK- didn't get to 0.65 before gas cut- disrupted @1.5s and looked like impurity increased dramatically ~1s maybe implying something dropping into plasma.
Mar 17 2010 11:02:08:537AM1100317008Basil DuvalPre: Repeat with faster initial gas ramp to get reversal before cut-
Post: OK- didn't get to transition (0.65 just reached)- ?
Mar 17 2010 11:23:54:500AM1100317009Basil DuvalPre: Repeat target 0.7-> 0.77 nl_04 @0.9s- Start to worry that transition is not reproducible ?
Post: BLIP- Somthing dropped in- Tungsten ?
Mar 17 2010 11:27:31:937AM1100317010Basil DuvalPre: Repeat-
Post: Huge influx of something @0.3s- Machine is not well- Prefill too low?
Mar 17 2010 11:40:58:677AM1100317011Basil DuvalPre: Repeat- increase prefill ?
Post: OK- but missing velocity reversal ?- Go back to best shot #4
Mar 17 2010 12:18:21:520PM1100317012Basil DuvalPre: Repeat- sho #004 (are we still in business ?)
Post: OK- Disrupt @0.6s- not getting us anywhere here ?-
Early density much lower than (from 60->100ms) #004- feed it more gas- Can we get back ?
Mar 17 2010 12:28:20:663PM1100317013Basil DuvalPre: Repeat-
Post: OK- Disrupt again--- locked mode?
Mar 17 2010 12:29:11:697PM1100317014Basil DuvalPre: Repeat- More early gas
Post: OK- No Rotation changes but offset on X-ray- Worried about this being a locked mode but not sure- Try real locked mode #002 to confirm
Mar 17 2010 12:42:20:390PM1100317015Basil DuvalPre: Repeat #002- Locked mode.... for sure ! (increase prefill to avoid disruption)
Post: OK- Strange and only "otherwise" usable shot- Te _900eV too low for Ar. try again !
Mar 17 2010 12:53:15:627PM1100317016Basil DuvalPre: Repeat #002- Locked mode.... for sure ! (increase prefill to avoid disruption)
Post: OK- Real Locked- X-ray spectrometer has drifted
Mar 17 2010 01:23:36:417PM1100317017Basil DuvalPre: Repeat #012- try to remove density "hole" @0.3-0.5s to stop locked mode-
Post: OK- Lost all X-ray data- still hole in Ne evolution and sawteeth were "odd"
Mar 17 2010 01:24:55:230PM1100317018Basil DuvalPre: Repeat #012- try to remove density "hole" @0.3-0.5s to stop locked mode-
Post: OK- Ne ramp started too high- some counter rotation that was extinguished at higher densities- sawteeth back to normal- Although period seems to have two distinct frequencies)
Mar 17 2010 01:47:57:503PM1100317019Basil DuvalPre: Repeat #012- reduce early gas to reduce lower value of ramp
Post: OK- little activity on X-ray (Lyman alpha missing)
Mar 17 2010 02:08:07:057PM1100317020Basil DuvalPre: Repeat #012- flat density
Post: OK- little activity on X-ray (Lyman alpha missing)- transition caused by Ninja-
Mar 17 2010 02:16:32:437PM1100317021Basil DuvalPre: Repeat #012- flat density (apart from Ninja still ON)
Post: OK- But still not limited=
Mar 17 2010 02:31:50:787PM1100317022Basil DuvalPre: Repeat #012- flat density Ninja-> OFF
Post: OK- still only marginally limited and Ar contribution to Zeff getting a little higher than one might want
Mar 17 2010 02:40:57:040PM1100317023Basil DuvalPre: Repeat #012- Further in radially
Post: OK- clearly limited- too much Ar- Density too high- No rotation change...
Mar 17 2010 02:51:48:810PM1100317024Basil DuvalPre: Repeat #012- Further in radially++, reduce Ar- lower early Ne
Post: OK- Too low ne- locked @0.3s blew @0.4- Try to halve change from #23 and then give up-
Mar 17 2010 03:07:13:970PM1100317025Basil DuvalPre: Repeat #012- increase early Ne to avoid lock- Clearly limited config
Post: OK- Great shot- Ne probably too high (c/f TCV results)- Co-rotation
Mar 17 2010 03:36:11:403PM1100317026Basil DuvalPre: Repeat- Program Ne=0.6- @0.8sec pull limited off wall -> diverted
Post: OK- Worked- Got strong Ne drop and Co -> counter swing on rotation- MUST LOOK AT THIS IN DETAIL WHEN IT's UNDERSTOOD
Mar 17 2010 03:54:35:317PM1100317027Basil DuvalPre: Repeat- #20 with density ramp from 0.6->1.5 sec qedge=3- AVOID LOCKING
Post: BLIP- Density V. High- Burp from somewhere (C V. High????)
Mar 17 2010 04:22:52:047PM1100317028Basil DuvalPre: TRY AGAIN- Repeat- #20 with density ramp from 0.6->1.5 sec qedge=3- AVOID LOCKING
Post: OK ! transition
Mar 17 2010 04:23:25:280PM1100317029Basil DuvalPre: Repeat q=4
Post: OK ! velocity doesn't move (Matt says we need lower Ne anyway)
Mar 17 2010 04:58:46:217PM1100317030Basil DuvalPre: Repeat q=5
Post: OK ! But no transition again
Mar 17 2010 04:59:03:700PM1100317031Basil DuvalPre: Repeat q=4, lower density
Post: OK ! But no transition again++
Mar 17 2010 05:00:03:153PM1100317032Basil DuvalPre: Repeat q=3.6 (900kA), same density
Post: OK ! TRANSITION @1.0s- So we were ALL right-
Mar 17 2010 05:20:19:223PM1100317033Basil DuvalPre: Last Shot- Locked mode Calibration based on #016-possibly---
Post: Disrupted !0.45s- Not enough for a real calibration

END OF DAY

Physics Operator Comments
Mar 17 2010 09:12:00:790AM1100317001Jim Irbyloaded from 1091216030
loaded seg 1 from 1100316032
Ip 1000 kA
prefill from -0.356 to -.0300 s
nl04 0.3e20/m^2
argon puff from 0.300 to 0.500 s
loaded

cryopump will be on


fizzle --- numerous physop screwups

Mar 17 2010 09:39:57:257AM1100317002Jim Irbychanges --------------------------------

loaded from 1100316030 --- locked mode cal shot
prefill at 26 ms
loaded

no cryopump


results --------------------------------

plasma into rampdown
Mar 17 2010 09:53:54:260AM1100317003Jim Irbychanges --------------------------------

loaded from 1100316006
loaded seg 1 from 1100316030 into seg 1
density ramp programmed
Ip from 800 to 1066 kA
loaded

results --------------------------------

plasma into rampdown
Mar 17 2010 10:07:17:483AM1100317004Jim Irbychanges --------------------------------

tweaked Ip rise a little
nl04 request down to 1.0e20/m^2 at 1.5 s
loaded

results --------------------------------

plasma into rampdown


Mar 17 2010 10:15:30:130AM1100317005Jim Irbychanges --------------------------------

nl_04 from 0.6 to 0.7e20 /m^2 from 0.6 to 1.6 s
loaded

results --------------------------------

plasma into rampdown
Mar 17 2010 10:28:04:760AM1100317006Jim Irbychanges --------------------------------

repeat

results --------------------------------

plasma into rampdown
Mar 17 2010 10:47:04:640AM1100317007Jim Irbychanges --------------------------------

nl04 request 0.7e20/m^2 at 1.0 s then down to 0.5e20/m^2
loaded

results --------------------------------

disruption at 1.576 s --- Matt sees large boron injection (W at 0.25 s)

Mar 17 2010 10:55:29:707AM1100317008Jim Irbychanges --------------------------------

modified density programming to give earlier ramp
prefill from 26 to 24 ms (disruption recovery)
loaded

results --------------------------------

disruption a little later at 1.62 s


Mar 17 2010 11:11:18:277AM1100317009Jim Irbychanges --------------------------------

nl04 request to 7.7e19/m^2 at 0.9 s
loaded

results --------------------------------

injection at 0.32 s --- plasma for 0.33 s
Matt sees boron/W

Mar 17 2010 11:31:51:360AM1100317010Jim Irbychanges --------------------------------

try again w/o flakes

results --------------------------------

plasma for 0.3 s --- lots of hards, density low during startup
Mar 17 2010 11:40:39:537AM1100317011Jim Irbychanges --------------------------------

prefill from 24 to 30 ms
loaded

results --------------------------------

plasma for 1.557 s
Mar 17 2010 11:58:47:420AM1100317012Jim Irbychanges --------------------------------

import seg 2 from 1100317004 into seg 2
loaded

results --------------------------------

plasma for 0.5 s --- locked modes
same programming resulted in much lower early density
Mar 17 2010 12:10:22:970PM1100317013Jim Irbychanges --------------------------------

nl04 request raised before 400 ms
pg3 puff earlier and higher
loaded

results --------------------------------

plasma for .625 s density higher early, but still drops well below programmed levels by 0.4 s

Mar 17 2010 12:22:15:600PM1100317014Jim Irbychanges --------------------------------

added more gas early with pg3
dropped early density in seg2 to fix overshoot
loaded


results --------------------------------

plasma into rampdown -- hards much better -- density still dropping until about 400 ms.
Mar 17 2010 12:46:12:013PM1100317015Jim Irbychanges --------------------------------

import seg 2 from 1100317002 into seg 2
added a little more gas early with pg3
loaded

results --------------------------------

plasma into rampdown --- wrong segment, but a very nice shot!

hards are gone. Density higher before 100 ms

try again...

Mar 17 2010 12:53:04:783PM1100317016Jim Irbychanges --------------------------------

import seg 4 from 1100317002 into seg 4
seg 2 off, seg 4 on
loaded

results --------------------------------

plasma into rampdown --- locked mode around 0.65 s --- marfe early, but no hards

Mar 17 2010 01:12:08:380PM1100317017Jim Irbychanges --------------------------------

import seg 2 from 1100317012 into seg 2
seg 4 off, seg 2 on
increased density request before 400 ms
loaded

results --------------------------------

plasma into rampdown --- still had dip in density


Mar 17 2010 01:24:57:027PM1100317018Jim Irbychanges --------------------------------

nl04 request increase from 300 to 500 ms
loaded

results --------------------------------

plasma into rampdown --- density dip much improved --- no hards


Mar 17 2010 01:35:27:200PM1100317019Jim Irbychanges --------------------------------

dropped density request before 0.4 s a little --- too high at start of ramp
loaded

results --------------------------------

plasma into rampdown --- density lower
Mar 17 2010 01:55:49:753PM1100317020Jim Irbychanges --------------------------------

no density ramp --- now flat at 0.55e20/m^2 from 0.5 s
loaded


results --------------------------------

plasma into rampdown --- NINJA brings up density
Mar 17 2010 02:11:33:170PM1100317021Jim Irbychanges --------------------------------

move it all over:
CLEARIN reduced by 0.015 m
RCUR reduced by 0.015 m
loaded

results --------------------------------

not limited --- gap still about 3 mm
Mar 17 2010 02:21:39:937PM1100317022Jim Irbychanges --------------------------------

CLEARIN reduced another 0.005 m
RCUR reduced another 0.005 m
loaded

results --------------------------------

plasma into rampdown --- limited (< 1 mm gap)

Mar 17 2010 02:41:28:320PM1100317023Jim Irbychanges --------------------------------

want it hard limited:

CLEARIN reduced another 0.005 m
ZXL reduced by .02 m
RXL flat at 0.00 m
nl_04 request reduced before 400 ms
loaded

results --------------------------------

plasma into rampdown --- still too wimpy a limit
Mar 17 2010 02:54:08:887PM1100317024Jim Irbychanges --------------------------------

CLEARIN reduced another .005 m
Argon puff cut in half to 100 ms
reduced pg3 puff by about 10 ms (hards again?)
loaded


results --------------------------------

plasma for 0.4 s --- locked mode
Mar 17 2010 03:27:20:227PM1100317025Jim Irbychanges --------------------------------

pg3 increased by 5 ms in attempt to get rid of locked modes
loaded

results --------------------------------

plasma for 1.5 s

Mar 17 2010 03:37:34:653PM1100317026Jim Irbychanges --------------------------------

from 0.8 to 0.9 s reverse changes to CLEARIN, RCUR, RXL: go from limited to diverted
loaded

results --------------------------------

plasma into rampdown --- diverted as programmed --- big density drop
Mar 17 2010 03:55:26:333PM1100317027Jim Irbychanges --------------------------------

import seg 2 from 1100317020 to seg
density ramp from 0.6 to 1.5 s of 0.55e20 to 0.7e20 /m^2
loaded

results --------------------------------

fizzle --- not sure of cause --- large CIII, pressure high
Mar 17 2010 04:02:00:663PM1100317028Jim Irbychanges --------------------------------

repeat

results --------------------------------

plasma into rampdown
Mar 17 2010 04:15:04:060PM1100317029Jim Irbychanges --------------------------------

Ip from 1066 to 800 kA

results --------------------------------

plasma into rampdown --- boring shot I'm told
Mar 17 2010 04:27:00:000PM1100317030Jim Irbychanges --------------------------------

Ip from 800 to 640 kA
loaded

results --------------------------------

plasma into rampdown
Mar 17 2010 04:41:31:100PM1100317031Jim Irbychanges --------------------------------

Ip back to 800 kA
nl04 ramp from 0.30e20 to 0.50e20/m^2
loaded

results --------------------------------

plasma into rampdown --- density too high to get upward going ramp
Mar 17 2010 04:51:57:090PM1100317032Jim Irbychanges --------------------------------

Ip from 800 to 900 kA
loaded

results --------------------------------

plasma into rampdown
Mar 17 2010 05:10:48:313PM1100317033Jim Irbychanges --------------------------------

seg 2 off, seg 4 on --- locked mode cal shot I hope
loaded

results --------------------------------

plasma for 0.46 s --- large moly injection, but also early drop in density


Mar 18 2010 08:58:27:017AM1100317033Ron ParkerShot 1 coming up
Mar 18 2010 08:59:30:267AM1100317033Ron ParkerShot 1 coming up

Engineering Operator Comments
ShotTimeTypeStatusComment
109:04:16:773AMPlasmaOk
209:21:19:500AMPlasmaOk
309:41:49:913AMPlasmaOk
409:55:54:010AMPlasmaOk
510:08:56:937AMPlasmaOk
610:21:47:943AMPlasmaOk
710:35:02:730AMPlasmaOk
810:48:46:297AMPlasmaOk
911:05:48:350AMPlasmaOk
1011:21:04:420AMPlasmaOk
1111:34:19:457AMPlasmaOk
1211:47:23:790AMPlasmaOk
1312:02:33:420PMPlasmaOk
1412:15:38:410PMPlasmaOk
1512:32:52:120PMPlasmaOk
1612:45:51:687PMPlasmaOk
1701:02:49:147PMPlasmaOk
1801:17:55:200PMPlasmaOk
1901:31:16:717PMPlasmaOk
2001:44:15:110PMPlasmaOk
2102:04:22:837PMPlasmaOk
2202:17:16:827PMPlasmaOk
2302:33:07:567PMPlasmaOk
2402:47:08:963PMPlasmaOk
2503:01:03:390PMPlasmaOk
2603:25:43:040PMPlasmaOk
2703:43:24:203PMPlasmaOk
2803:56:27:270PMPlasmaOk
2904:09:13:447PMPlasmaOk
3004:22:41:483PMPlasmaOk
3104:35:35:613PMPlasmaOk
3204:48:49:510PMPlasmaOk
3305:05:16:517PMPlasmaBadComm. failure on OH2OH1 self powered ckt. fired

System Availability
Mar 17 2010 09:03:49:977AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyes7 horizontal views spread out R_maj=[0.72-0.9m], 3 cm over the tokamak midplane (beam) Jul 09 2009 05:12PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (diode+foil), AXA, AXJ, WB3AX, WB4AX, LEDGE-AX working fine. MID-FOILS working fine. The LEDGE/DIV foils still need calibrations appliedAug 27 2009 09:09AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationyes Nov 13 2009 06:37AM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesOperationalNov 09 2009 09:12AM (irby)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesThe wide-view toroidal array was installed, spatially and absolutely calibrated. There are 7 toroidal chords intersect the beam at the major_R_range=[74.2:83.6]cm. Spatial resolution: 1.2 cm. The F-top wide-view poloidal array was installed and spatially calibrated. There are 19 chords intersect the beam at the major_R_range=[0.65:0.9.]m. Spatial resolution: 1.22 cm.Jul 09 2009 05:16PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned and operating; not yet calibratedJul 14 2009 02:22PM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationyesoperational, but turned offNov 03 2009 04:59PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnoin test mode onlyNov 03 2009 05:01PM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCyes Nov 09 2009 09:13AM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll channels working and calibrated.Feb 02 2010 09:56AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauge installed. Controller repaired.Aug 23 2009 10:36PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow Dischargeno6/10/09: Paddles meggered at 1000 v to machine ground (>300 Mohm) prior to closing the vacuum chamber. Plugs for Power Supply and Controls Unplugged and Red Tagged, Safe for In-Vessel AccessJun 10 2009 01:47PM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesposes no safety hazard for people working around the machineJun 18 2009 01:04PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Oct 27 2009 10:39AM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installed and testedJun 17 2009 11:54AM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryescurrently only one detector is operational, off-axis He-like argon emissionJul 14 2009 10:01AM (rice)John RiceHigh Resolution X-Rayince,rice
HXRnoIn safe mode (high voltage turned off)May 27 2008 09:19PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayesoperational at 80 MHzJul 21 2009 04:49PM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayesantenna and FFT operationalJul 21 2009 04:49PM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayesavailable at 80 MHz and [0,pi,0,pi] phasingSep 04 2009 10:01AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-OffyesRequires some advance notice for laser start-upOct 16 2009 12:46PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoBreaker locked and tagged out. Waveguide disassembly started. Open Waveguides have been shorted.May 28 2008 09:47AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane, WB4-LY, LEDGE-LY all collecting data. WB1-LY not attached.Aug 27 2009 09:10AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesOperating normallyAug 27 2009 09:10AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Recalibrated 7/27/09.Jul 28 2009 04:22PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are on. B-bottom is not operating - bad sensor head?Jul 14 2009 09:12PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesNeutron detectors are calibrated and ready to go. Voltages will be turned on prior to first plasma.Jun 10 2009 10:35AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesPower back on morning of 11/09 before runNov 09 2009 09:10AM (irby)Jim IrbyX-Ray/Neutron Detector at K-Horirby
NINJAnoCapillaries were tested in-vessel. Plenum has a leak and needs fixing.Jul 14 2009 09:14PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesOperational.Nov 12 2009 02:36PM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,ennever,ntsujii,porkolab
Penning GaugesyesHigh voltage is enabled (on during INIT, off during RECOOL).Jun 30 2009 09:42PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air SwitchyesChecked and Operational as of 06/18/09Jun 19 2009 08:04AM (irby)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Nov 13 2009 06:38AM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power SystemsyesChecked out and ready for Magnet Tests as of 06/18/09Jun 19 2009 08:07AM (irby)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesArray is operational with new cPCI data system. Probe 14 has open circuit.Jul 14 2009 09:17PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHnoLH launcher not installed. Cables are unplugged at the A-port rack.Jul 14 2009 09:16PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesArray is operational with new cPCI data system.Jul 14 2009 09:16PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesArray is operational with new cPCI data system. Probe 13 has a bad cable (open).Jul 14 2009 09:17PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesSince 1100120000 the system is operational except for channel 110 which is not installedJan 20 2010 09:17AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesProbe is operational. Needs plasma conditioning.Jul 14 2009 09:18PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesSystem connected to A-port WASP. Needs plasma testing.Jul 14 2009 09:19PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesSparker back in operation before 11/09 runNov 09 2009 09:11AM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
TCIyesSystem restarted and aligned. Several chords available including NL04. Density Feedback available. Ready for plasma.Jun 18 2009 09:15AM (murray)Jim IrbyTwo-Color Interferometerirby,murray
TS - Coreyes2 lasers working. 15 spatial channels operational. Calibrated Oct 13 2009 07:49PM (yma)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgeyesOperational, and calibrated.Oct 11 2009 03:01PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XTOMOyesOperating normallyAug 27 2009 09:10AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke