Alcator C-Mod Run 1100713 Information

Back to runs

Miniproposals
Miniproposal:534
Date Filed: 2/21/2008
Title:Foil/AXUV Bolometer Calibration in Helium
First Author:Matt Reinke
Session Leader:Matt Reinke (shots 1-34)

Operators
Session leader(s):Matt Reinke
Physics operator(s):Jim Irby
Engineering operator(s):Bill Cochran,Andy Pfeiffer,Bill Byford

Engineering Operator Run Comment
MP534: Foil/AXUV Bolometer Calibration in Helium

Session Leader Plans
Entered: Jul 12 2010 11:38:58:820AM
Author: Matt Reinke
MP534: Foil/AXUV Bolometer Calibration in Helium

The purpose of this run is to calibrate the bolometry, Lyman-a and the HIREXSR diagnostics. Helium is used as the main-ion to reduce C-X contributions on the foil bolometry and check the filter transmission of the Lyman-a tools.
ICRF conditioning will also be piggybacking as we try to bring up the PTOT for the first time this campaign and the He main-ion helps to eliminate trips due to high neutral pressure.

SETUP:
-------
ECDC in He the night before. Main ion fueling will be He but use D2 for reliable startup. Fill B-SIDE-LOWER with 1 psi Ar.

TO-DO:
-------
1) ISOTOPE CHANGEOVER (5-10 shots)
Run the isotope changever shots in LSN, repeating 1100709023 (800 kA, nl04=1.0 ZSEPS sweep w/ cryopump) and let ICRF condition D/E/J as necessary but keep PINPUT <= 1-2 MW, starting low and checking heat flux diagnostics before increasing.
Enable 100 ms Ar puff for HIREXSR to adjust crystal alignment (no masks)
Monitor D_a, Ly_a on midplane to verify isotope exchange.

2) DIVERTOR LYMAN-A CHECK (2-3 shots)
After isotope changever satisfactory, run Ohmic only to test isotope effect on heat flux and check Lyman-a divertor filter throughput. Set Ar to 50 ms puff.
Repeat Ohmic shot at lower density (1100709019) w/ nl04 ~ 0.7

3) OUTER GAP SCAN (2-3 shots)
after HIREXSR alignned run outer gap scan plasmas like 1100205013 (Ohmic only w/ Ip scan and no cryopump)

4) AXUV/FOIL BOLOMETER CALIBRATION (6-7 shots)
Switch to 1100205007 (1 MA, nl04=0.9, USN, 1-2 psi Ar steady 0.3-1.2,use cryopump w/ 2-3 MW of ICRF (D+E only), ICRF during rampdown).
Once Ar-seeded dischrage is repeatable, do HIREXSR masking tests (4-5 shots)
Adjust Ar pressure/duty cycle and ICRF as necessary to try and get close to 100% PRAD.

5) ICRF PTOT CONDITIONING (rest of day)
Adjust ICRF D/E/J mix and impurity seeding as necessary for conditioning and run more shots.
Increase PINPUT to maximum available, keeping an eye PRAD and LIMITER/DIVERTOR temperatures.

Physics Operators Plans
Entered: Jul 12 2010 05:05:55:270PM
Author: Jim Irby
-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Power systems as on: 1100709023

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid ENABLED (PG1) **** note enabled ***
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi Helium Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gatevalves and shutters: ECE, VUV, HiREX Sr, Z-bolo, ZEUS

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes
ICRF(yes/no): no
LH(yes/no): no
Cryopump (yes/no): yes --- for 1st shot

Vessel temperature: 45/45/45 during run

------------------------------
ECDC Parameters (if requested)
------------------------------
gas and pressure: Helium at 5e-5 Torr
sweep: 44/45/103 cm
scan: 20/120 s

Session Leader Summaries
Entered: Jul 13 2010 05:10:47:483PM
Author: Matt Reinke
A typical Tuesday of a run. We got a late (~30 minutes) due to an alternator problem. We struggled with density control early but lowering the target to about 25% below desired seemed to work.

We were able to get all three ANT separately to have ~ 1 MW, 300 ms pulses. Tried D and E at 1.5 MW but wasn't able to get a steady pulse. Also D+E overlap caused problems, possibly releasing material from the lower C-SIDE of the D-ANT. We weren't able to get the ICRF at the level to work on (4) or (5). We then switched to Ohmic to exploit the isotope changeover (1) and so we completed (2) from the SL_PLAN.

The last few shots had poor startups with runaways and 034 was shut down by DPCS and showed no energy flux to the LFS limiters. Compared to 032 which would have been shut down by DPCS but died prior to 0.1 seconds and did show energy flux on K-LIM.

1-3 : cycle tests
4-27 : ICRF conditioning (4-16 at 5.5 T and 17-27 at 6.0 for MC tests)
28-34 : were Ohmic comparisons from 1100709 to test divertor Lyman-a filters

Physics Operator Summaries
Entered: Jul 13 2010 06:05:00:560PM
Author: Jim Irby
We had many fizzles today, and several 800 kA distruptions, as we tried
to condition the rf antennas. We started up from 1100709023 and varied
very little except the density programming all day. Following shot 31,
which was an unexplained fizzle, discharges 32, 33, and 34 all had large
hard x-ray levels. Shot 34, which lasted 200 ms, was shutdown by the
DPCS because of these high levels. Shot 32 actually had periods of time
in which all the SSD hard x-ray detectors saturated (5e-6, and 5e-7 A).
Shot 30, which ran full length, did have multiple injections, but not
major ones. After shot 30 we did not have a good plasma. I added more
and more prefill w/o success. I did not try increasing the pg3 seg 1
puff, which might have been a better thing to do. The neutral pressure
at breakdown by shot 34 was higher than on shot 30, but the early
density refused to rise.

On shots 01, 02, and 03 we ran cycle tests to exercise pg3 before the
run. We confirmed that the main gas puff does not work well on the
first shot of the day (or run week).


Problems:

Data system critical init failure resulted in one no power shot (shot
23, ef4 camac issue).

Cryopump dump resulted in one of the fizzles (24)

Hards on shot 32, 33, 34.

Score:

gas test 01,02,03
no power 23

fizzles 5,8,15,19,21,24,28,31

plasma 4,6,7,9,10,11,12,13,14,16,
17,18,20,22,25,26,27,29,30,
32,33,34


Session Leader Comments
Jul 13 2010 09:36:40:403AM1100713004Matt ReinkeLarge MARFE (caused by Ar puff?) raises density to an absurd level.

NEXT: repeat w/ 50 ms Ar puff
Jul 13 2010 10:14:34:590AM1100713006Matt ReinkeFull length shot. Still getting signal on the LYMAN system. D,E OK, J looks ratty. Continue with isotope changeover and conitioning....to He not to hydrocarbon main-ion plasmas, though.

NEXT: Repeat
Jul 13 2010 10:29:08:360AM1100713007Matt ReinkeAnother early disruption. Loose density control after t~0.7. Get Fe and Mo from ICRF+MSE heat shield.

NEXT: drop Ar back to 50 ms
Jul 13 2010 10:51:16:917AM1100713009Matt ReinkeAnother early disruption, density control can't be maintained.

NEXT: Lower target to nl04~0.7 to try and lose the MARFE.
Jul 13 2010 11:10:53:507AM1100713010Matt ReinkeLarge Mo injection just after 0.43 and see a spray on the WIDE2 and D-ANT camera that's around the D-ANT limiter.
Jul 13 2010 11:30:37:090AM1100713011Matt ReinkeA full length shot!!!. Density higher than demand but actually closer to what I want (nl04~0.95). Decent D+E, J still icky.

NEXT: Repeat, add IMPINJ (CaF2) test in the rampdown 1.55. Increase D and E to 1.5 MW
Jul 13 2010 11:53:14:537AM1100713012Matt ReinkeD+E ratty at 1.5 MW, J-ANT looking better. No large change in the limiter energy fluxes.

NEXT: Repeat to get ANT conditioning.
Jul 13 2010 12:06:07:037PM1100713013Matt ReinkeClean J-ANT pulse at 1 MW total, D+E still tripping at 1.5 MW. The density actually stays controlled on this one and reaches the actual target of nl04~0.7

NEXT: Assume (naively?) that density control will be maintained and raise target to nl04=0.9. Repeat w/ J-ANT at 1.5 MW total.
Jul 13 2010 12:18:52:130PM1100713014Matt ReinkeMo comes in after 0.6 and helps to lead to the disruption.

NEXT: Repeat w/ ICRF mix/balance changed. Overlapping D+E at 1 MW each for short period of time.
Jul 13 2010 12:47:08:640PM1100713016Matt Reinkestill chasing ANT conditioning. Got a large spray from D-ANT after 1.0 seconds that help euthanize the plasma.

NEXT: Raise BT to 6.0 to get data on the MC for PCI and continue ANT de-shitting (Wukitch's wording)
Jul 13 2010 01:00:53:517PM1100713017Matt ReinkeFull length plasma, but bad ICRF.

NEXT: Repeat
Jul 13 2010 01:22:50:877PM1100713018Matt ReinkeEarly disruption, looks like a low-Z injection, nl04 target creeping up again.

NEXT: Repeat w/ nl04 target at 0.7
Jul 13 2010 01:51:38:850PM1100713020Matt ReinkeSubstantial impurities from 0.6-1.1. Cu, Fe Ni and perhaps Cr

NEXT: Repeat w/ ICRF adjustments
Jul 13 2010 02:14:25:237PM1100713022Matt ReinkeD-ANT had a clean pulse but E and J had multiple trips. Cleaner, full length plasma.

NEXT: Repeat
Jul 13 2010 03:00:12:053PM1100713025Matt ReinkeLots of Fe, Ni and Cu impurity injections. See blow off from D-ANT Faraday screen after 0.8 seconds.
G/H limiter lights up/sparks during E-ANT and J-ANT pulses. No significant heat flux on thermocouples, though so likely just heat thermally disconnected layers of B and blowing them off the limiter.

NEXT: Repeat
Jul 13 2010 03:15:58:533PM1100713026Matt ReinkeSimilar ratty RF. Steve suggests D/E interaction.

NEXT: Repeat w/o ICRF overlap
Jul 13 2010 03:23:08:277PM1100713027Matt ReinkeShot looked good until Mo injection at 0.875
Jul 13 2010 03:36:40:227PM1100713028Matt ReinkeFizzle.

NEXT: Switch to Ohmic only for divertor Lyman-a and heat flux check. Repeat 011 w/o ICRF.
Jul 13 2010 03:53:28:927PM1100713029Matt ReinkeGood shot as a match for 1100709023. Density up near nl04~1.0 despite a demand of 0.7.

NEXT: Reduce nl04 demand = 0.6 and repeat shot. Brian's going to add probes.
Jul 13 2010 04:05:35:007PM1100713030Matt ReinkeAnother good Ohmic shot, w/ nl04 down to 0.8.

NEXT: Repeat w/ nl04=0.5
Jul 13 2010 04:41:10:773PM1100713032Matt ReinkeFizzle/early runaway shot. Steve says it would have tripped DPCS but it only lasted till 0.06 seconds. The K-LIM sees the energy rise but after adjusting for the deposition time (0.01 seconds) it's still about 1/4 of the melting energy flux.

NEXT: Repeat sans runaways
Jul 13 2010 05:14:08:570PM1100713034Matt ReinkeEarly shutdown due to neuts/hards. This one showed no energy flux to the LFS limiters in contrast to 032 which had finite flux. Could be chance, but otherwise a successful test of the machine protection system.

Physics Operator Comments
Jul 13 2010 11:02:24:733AM1100713001Jim Irbyloaded from 1100709023
argon puff (pg1) from 300 to 400 ms.
open tree done

prefill ok for cryopump: 50 ms

------------------------------

main gas puff test

we got gas

repeat to check reproducibility



Jul 13 2010 08:13:00:603AM1100713002Jim Irbychanges --------------------------------

another gas check

results --------------------------------

main gas puff 50% higher on this shot (0.13 vs 0.22 mTorr at 0.4 s)




Jul 13 2010 08:34:45:150AM1100713003Jim Irbychanges --------------------------------

another test of gas puff

results --------------------------------

main gas puff very similar to shot 2. So we only need one shot to free up the valve.
Jul 13 2010 09:49:32:370AM1100713004Jim Irbychanges --------------------------------

no changes

alternator delayed us about 30 minutes


results --------------------------------

plasma for 0.944 s --- startup good --- cryopump worked well

density very high, disruption ---- pg3 programming in seg 2, 100 ms argon?
Jul 13 2010 10:08:07:693AM1100713005Jim Irbychanges --------------------------------

argon from 300 to 350 ms
pg3 seg 2 programming zeroed
loaded
open tree done


results --------------------------------

fizzle ---- large CIII
Jul 13 2010 10:15:34:523AM1100713006Jim Irbychanges --------------------------------

no changes

results --------------------------------

plasma into rampdown (1.7 s)

still lots of carbon, large MARFE early
Jul 13 2010 10:29:53:080AM1100713007Jim Irbychanges --------------------------------

argon from 300 to 375 ms
open tree done

results --------------------------------

plasma for 0.785 s
Jul 13 2010 10:35:39:710AM1100713008Jim Irbychanges --------------------------------

argon puff back to 50 ms, 300 to 350 ms
nl_04 proportional gain back to 1 from 2
loaded

results --------------------------------

fizzle ---
Jul 13 2010 10:53:02:960AM1100713009Jim Irbychanges --------------------------------

no changes

results --------------------------------

plasma for 1 s --- still have large uncontrolled density rise starting around 0.6 s.





Jul 13 2010 11:09:13:190AM1100713010Jim Irbychanges --------------------------------

nl04 request from 1.0e20 to 0.7e20/m^2
loaded

prefill from 50 to 45 ms disruption recovery I hope..
loaded


results --------------------------------

plasma for 0.46 s --- something blew in ---- d-antenna activity
Jul 13 2010 11:24:59:817AM1100713011Jim IrbyBill C and Andy in cell before this shot to check out EF2 voltage issue.

changes --------------------------------

no changes

results --------------------------------

plasma well into rampdown

Jul 13 2010 11:50:01:967AM1100713012Jim Irbychanges --------------------------------

repeat --- leave prefill at 45 ms

results --------------------------------

plasma into rampdown
Jul 13 2010 12:04:03:833PM1100713013Jim Irbychanges --------------------------------

no changes

results --------------------------------

plasma into rampdown --- still bringing up ICRF


Jul 13 2010 12:19:29:603PM1100713014Jim Irbychanges --------------------------------

nl04 request from 0.7 to 0.9e20 /m^2
open tree done

results --------------------------------

plasma for 0.78 s --- ICRF...
Jul 13 2010 12:34:23:717PM1100713015Jim Irbychanges --------------------------------

no changes

results --------------------------------

fizzle --- CIII up


Jul 13 2010 12:45:12:400PM1100713016Jim Irbychanges --------------------------------

no changes

results --------------------------------

plasma for 1.08 s --- injection from antenna



Jul 13 2010 01:03:41:957PM1100713017Jim Irbychanges --------------------------------

TF from 5.5 to 6.0 T --- request 166.6 kA
loaded

TF limit to 170 kA

results --------------------------------

plasma into rampdown --- 5.974 T
Jul 13 2010 01:23:53:183PM1100713018Jim Irbychanges --------------------------------

Amanda goes into lab to set up for 6 T

no changes

results --------------------------------

plasma for 0.9 s

Jul 13 2010 01:34:33:080PM1100713019Jim Irbychanges --------------------------------

nl04 from 0.9 to 0.7e20 /m^2
loaded

results --------------------------------

fizzle --- factor of 2 in carbon
Jul 13 2010 01:46:47:043PM1100713020Jim Irbychanges --------------------------------

no changes

results --------------------------------

plasma into rampdown
Jul 13 2010 02:02:45:203PM1100713021Jim Irbychanges --------------------------------

nl04 request to 0.9e20/m^2 before 0.4 s
loaded

results --------------------------------

fizzle ---
Jul 13 2010 02:21:57:637PM1100713022Jim Irbychanges --------------------------------

entered cell to add 5 m cable delay to polar det_ref signal

no changes

results --------------------------------

plasma into rampdown --- higher density at 0.6 s
Jul 13 2010 02:24:16:430PM1100713023Jim Irbychanges --------------------------------

results --------------------------------

no power shot ---- Critical init failure (IGOR)
Jul 13 2010 02:37:27:510PM1100713024Jim Irbychanges --------------------------------

try again --- no changes


results --------------------------------

fizzle --- cryopump dump
Jul 13 2010 02:54:58:470PM1100713025Jim Irbychanges --------------------------------

no changes --- try again

results --------------------------------

plasma into rampdown even with cryopump dump in CHECK --- fill 0.1 mTorr at breakdown.





Jul 13 2010 03:15:41:973PM1100713026Jim Irbychanges --------------------------------

no changes

results --------------------------------

plasma into rampdown
Jul 13 2010 03:27:50:137PM1100713027Jim Irbychanges --------------------------------

a few ICRF changes
no dpcs changes

results --------------------------------

plasma for 0.89 s




Jul 13 2010 03:33:38:637PM1100713028Jim Irbychanges --------------------------------

prefill from 45 to 43 ms
loaded

results --------------------------------

fizzle
Jul 13 2010 03:54:10:283PM1100713029Jim Irbychanges --------------------------------

turning off ICRF for a while

Tf back down to 152.8 kA (5.5 T)
loaded seg 2 from 1100713011 into seg 2

loaded


results --------------------------------

plasma into rampdown
Jul 13 2010 04:06:40:143PM1100713030Jim Irbychanges --------------------------------

nl04 request from 0.7e20 to 0.6e20 /m^2 with early 'puff' to 0.9e20/m^2 to help fill in density dip around 0.5 s.

open tree done


results --------------------------------

plasma into rampdown.
Jul 13 2010 04:23:57:113PM1100713031Jim Irbychanges --------------------------------

nl04 request to 0.5e20/m^2
loaded

results --------------------------------

fizzle!
Jul 13 2010 04:38:55:370PM1100713032Jim Irbychanges --------------------------------

try again --- no dpcs changes

results --------------------------------

let fill get too low --- 80 kA, 63 ms long plasma

all hard x-ray signals saturated at some point during the discharge

Jul 13 2010 04:51:55:133PM1100713033Jim Irbychanges --------------------------------

prefill to 49 ms from 43 ms
loaded

results --------------------------------

another run-away shot, though not as bad as 32.

Jul 13 2010 05:08:06:883PM1100713034Jim Irbychanges --------------------------------

prefill increased again to 52 ms
loaded

results --------------------------------

plasma for 200 ms before DPCS shuts us down because of hards

Engineering Operator Comments
ShotTimeTypeStatusComment
107:53:34:320AMTestOkShot Cycle Test
208:07:15:513AMTestOkShot Cycle Test
308:24:14:543AMTestOkShot Cycle Test
409:27:58:290AMPlasmaOk
509:49:39:190AMPlasmaOk
610:05:26:360AMPlasmaOk
710:19:17:833AMPlasmaOk
810:33:11:890AMPlasmaOk
910:46:27:667AMPlasmaOk
1011:03:18:890AMPlasmaOk
1111:17:29:937AMPlasmaOk
1211:43:25:873AMPlasmaOk
1311:58:42:493AMPlasmaOk
1412:11:39:700PMPlasmaOk
1512:24:54:533PMPlasmaOk
1612:37:53:543PMPlasmaOk
1712:55:17:737PMPlasmaOk
1801:13:30:777PMPlasmaOk
1901:26:25:887PMPlasmaOk
2001:39:47:140PMPlasmaOk
2101:53:05:937PMPlasmaOk
2202:06:14:320PMPlasmaOk
2302:19:23:730PMPlasmaBadcritical init failure
2402:34:57:103PMPlasmaOk
2502:49:18:810PMPlasmaOk
2603:03:59:763PMPlasmaOk
2703:17:43:333PMPlasmaOk
2803:31:11:247PMPlasmaOk
2903:45:21:387PMPlasmaOk
3003:59:29:353PMPlasmaOk
3104:14:07:213PMPlasmaOk
3204:28:19:470PMPlasmaOk
3304:42:22:813PMPlasmaOk
3404:57:25:797PMPlasmaOk

System Availability
Jul 13 2010 07:53:21:803AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESnoBES system is ready for Up-to-air (Apr, 2010)Mar 31 2010 10:36AM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (D+F) working. All midplane and off-midplane diode arrays working except WB1AX. No midplane or divertor foils yet.Jul 01 2010 11:58AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationno3/26/10 Bottle Removed From Cell, monitors powered down, Autodialer function bypassedMar 26 2010 05:29PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoShut down. Helium dewar removed. LN2 manual valve and solenoid valves are closed and tagged.Apr 06 2010 10:51AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSnoWide-view CXRS system is power down and ready for up-to-air (Apr, 2010)Mar 31 2010 10:36AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned; new calibrations (relative brightness and position) not yet implementedJun 29 2010 10:27AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationyesoperational, but turned offNov 03 2009 04:59PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnoin test mode onlyNov 03 2009 05:01PM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCyesOperationalJun 26 2010 09:28PM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll channels working - calibration in progressJul 02 2010 09:30AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauges are operational.Jun 28 2010 08:02PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoPlugs for Power Supply and Controls have been unplugged and red tagged making system safe for In-Vessel Access.Apr 05 2010 11:18AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational. Ch 5 preamp replaced 6/18.Jun 22 2010 03:03PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesoperating normallyJun 29 2010 10:26AM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Jun 26 2010 11:19PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryessystem installed and alignedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice,ypodpaly
HXRyes Jun 28 2010 12:12PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayessystem checked out ok on 11006728. Jun 28 2010 04:57PM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayessystem checked out ok on 1100628Jun 28 2010 04:57PM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayessystem checked out ok. conditioned to vacuum. Jun 28 2010 04:58PM (ylin)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-OffnoLaser is disconnected and the vacuum system is removed.Apr 06 2010 10:01PM (nthoward)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridyesLH was tested into dummy loads synced to shot. Shorts have been removed. Probe Cal. 6/29/10 evening.Jun 29 2010 03:51PM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesLYMID, WB4LY and LLY working. WB1LY not attached due to pickup problems.Jul 01 2010 11:58AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesData being collected, but MCP voltages not being reported so analyzed data is unavailable.Jul 01 2010 11:57AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Start at reduced speed.Jun 22 2010 03:02PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are operationalJun 28 2010 08:02PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesAll systems are on and functionalJun 29 2010 12:56PM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesPMT Neuts_hards, ssd_x01, ssd_x02, ssd_x03Jun 26 2010 09:21PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAnoCapillaries tested in-vessel.Jun 28 2010 08:08PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesOperational. AM 2 * 38.19 MHz.Jul 02 2010 09:46AM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,ennever,ntsujii,porkolab
Penning GaugesnoHigh voltage power supplies are turned off, waiting for work at A-port horizontal to be finished.Jun 28 2010 08:07PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Jun 26 2010 11:19PM (dekow)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Jun 26 2010 11:19PM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Jun 26 2010 11:19PM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Jun 26 2010 11:20PM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational.Jun 28 2010 08:03PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational.Jun 28 2010 08:03PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesF and J outer divertor probes are operational.Jun 28 2010 08:04PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperational, except probe#13Jun 28 2010 08:04PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometernooffJun 26 2010 10:02AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational. New Langmuir-Mach probe head installed.Jun 28 2010 08:05PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.Jun 28 2010 08:05PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesBoth A and K units are operational. Coil polarity needs to be checked.Jun 28 2010 08:06PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesHV supply on, cable run to sparker at k-horJun 23 2010 02:41PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationnoSSS installed and leak tested, individual probes not installedJun 28 2010 01:28PM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesNo new CO2 detector, so still missing edge channelsJun 23 2010 02:40PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CorenoLasers are shuttered and interlocked. All beams are blocked from entering the cell.Mar 31 2010 05:10PM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgenoLasers are shuttered and interlocked. All beams are blocked from entering the cell.Mar 31 2010 05:11PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesOperationalJul 01 2010 11:57AM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermlreinke
XTOMOyesCore system working. Edge system waiting for H-modes.Jul 01 2010 11:55AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke

Jul 13 2010 09:27:45:617AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESnoBES system is ready for Up-to-air (Apr, 2010)Mar 31 2010 10:36AM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (D+F) working. All midplane and off-midplane diode arrays working except WB1AX. No midplane or divertor foils yet.Jul 01 2010 11:58AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationno3/26/10 Bottle Removed From Cell, monitors powered down, Autodialer function bypassedMar 26 2010 05:29PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAnoSingle channel CNPA available as of 12/1707Jun 10 2009 10:22AM (twf)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoShut down. Helium dewar removed. LN2 manual valve and solenoid valves are closed and tagged.Apr 06 2010 10:51AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSnoWide-view CXRS system is power down and ready for up-to-air (Apr, 2010)Mar 31 2010 10:36AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned; new calibrations (relative brightness and position) not yet implementedJun 29 2010 10:27AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationyesoperational, but turned offNov 03 2009 04:59PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnoin test mode onlyNov 03 2009 05:01PM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCyesOperationalJun 26 2010 09:28PM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll channels working - calibration in progressJul 02 2010 09:30AM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauges are operational.Jun 28 2010 08:02PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoPlugs for Power Supply and Controls have been unplugged and red tagged making system safe for In-Vessel Access.Apr 05 2010 11:18AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational. Ch 5 preamp replaced 6/18.Jun 22 2010 03:03PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesoperating normallyJun 29 2010 10:26AM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Jun 26 2010 11:19PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex Sryessystem installed and alignedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice,ypodpaly
HXRyes Jun 28 2010 12:12PM (schmidt)Ron ParkerHard X-Ray Arrayparker,schmidt
ICRF D-Antennayessystem checked out ok on 11006728. Jun 28 2010 04:57PM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayessystem checked out ok on 1100628Jun 28 2010 04:57PM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayessystem checked out ok. conditioned to vacuum. Jun 28 2010 04:58PM (ylin)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-OffnoLaser is disconnected and the vacuum system is removed.Apr 06 2010 10:01PM (nthoward)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridyesLH was tested into dummy loads synced to shot. Shorts have been removed. Probe Cal. 6/29/10 evening.Jun 29 2010 03:51PM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesLYMID, WB4LY and LLY working. WB1LY not attached due to pickup problems.Jul 01 2010 11:58AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesData being collected, but MCP voltages not being reported so analyzed data is unavailable.Jul 01 2010 11:57AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Start at reduced speed.Jun 22 2010 03:02PM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are operationalJun 28 2010 08:02PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesAll systems are on and functionalJun 29 2010 12:56PM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesPMT Neuts_hards, ssd_x01, ssd_x02, ssd_x03Jun 26 2010 09:21PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAnoCapillaries tested in-vessel.Jun 28 2010 08:08PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesOperational. AM 2 * 38.19 MHz.Jul 02 2010 09:46AM (ntsujii)Miklos PorkolabPhase Contrast Imagingarai,ennever,ntsujii,porkolab
Penning GaugesnoHigh voltage power supplies are turned off, waiting for work at A-port horizontal to be finished.Jun 28 2010 08:07PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Jun 26 2010 11:19PM (dekow)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Jun 26 2010 11:19PM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Jun 26 2010 11:19PM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Jun 26 2010 11:20PM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational.Jun 28 2010 08:03PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational.Jun 28 2010 08:03PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesF and J outer divertor probes are operational.Jun 28 2010 08:04PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperational, except probe#13Jun 28 2010 08:04PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesOn 1100713xxx the 50, 112 (the replacement for 110), 140 and 60GHz fixed are connected and being tested. Variable frequency channel also connected and being tested. System also setup for testing ICRF mode conversion feature.Jul 13 2010 08:30AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational. New Langmuir-Mach probe head installed.Jun 28 2010 08:05PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.Jun 28 2010 08:05PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesBoth A and K units are operational. Coil polarity needs to be checked.Jun 28 2010 08:06PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesHV supply on, cable run to sparker at k-horJun 23 2010 02:41PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationnoSSS installed and leak tested, individual probes not installedJun 28 2010 01:28PM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesNo new CO2 detector, so still missing edge channelsJun 23 2010 02:40PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CorenoLasers are shuttered and interlocked. All beams are blocked from entering the cell.Mar 31 2010 05:10PM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma,zhang
TS - EdgenoLasers are shuttered and interlocked. All beams are blocked from entering the cell.Mar 31 2010 05:11PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma,zhang
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesOperationalJul 01 2010 11:57AM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermlreinke
XTOMOyesCore system working. Edge system waiting for H-modes.Jul 01 2010 11:55AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke