Alcator C-Mod Run 1110203 Information

Back to runs

Miniproposals
Miniproposal:642
Date Filed: 1/27/2011
Title:Assessing feasibility of producing hybrid scenario on C-Mod with LHCD
First Author:Amanda Hubbard
Session Leader:Amanda Hubbard (shots 1-28)

Operators
Session leader(s):Amanda Hubbard
Physics operator(s):Ron Parker
Engineering operator(s):Roza Tesfaye,Bill Parkin,Bill Byford

Engineering Operator Run Comment
MP 642: Assessing feasibility of producing 'hybrid' scenario on C-Mod wi

Session Leader Plans
Entered: Feb 2 2011 11:16:17:660AM
Author: Amanda Hubbard
Run Plan for Thurs, Feb 3rd

MP 642: Assessing feasibility of producing 'hybrid' scenario on C-Mod with LHCD
Session Leader: Amanda Hubbard
Physics Operator: Ron Parker

Key systems and diagnostics: ICRF (all available, start with J+E), LHCD, Cryopump (from first shot), DNB, MSE, Polarimetry, Edge TS, fast MHD, hard x-ray camera.
Request overnight ECDC in HELIUM to outgas the walls.

This run is the first of a two-day MP aimed at modifying the current profile with LHCD (ideally broadening, with q0 around 1), then making H-modes with ICRF. Key questions are:
- Can the j(r) modification be maintained during ICRF and H-mode?
- Are the H-modes changed, either continuously or transiently, as a result of j(r) differences?

We will start at low current, 450 kA, to give the lowest H-mode density and greatest relative current drive. Good starting shot is 1110106030 (5.4 T) . But, we will want to move to USN early in the flat top, and slow down the current ramp, to reach flat top by more like 350 ms (as on 1080414, Sips hybrid expt), and ideally avoid the overshoot.

1) First few shots will use ICRF only, varying density to find the minimum which gives steady H-modes. LHCD may wish to tune/condition later in the discharge. Keep an eye on k-limiter heating, and keep ICRF pulses short to start. (If it is a big problem we may need to move to 600 kA earlier).

2) We will then start applying LHCD, varying timing and N// to delay/reduce sawteeth until well into flat top (and ideally maintaining density similar
to the optimum in step 1). Will look at discharges on 1080414, which successfully modfied j(r), as a guide; starting about 200 ms seemed to work well. Will make sure to have an ohmic period late in flat top to calibrate MSE vs EFIT. Anticipate a number of discharges with varying parameters. May want to use lower N// during the rampup, then increase at or before the ICRH turnon.
3-5 discharges.

3. Add ICRH (~ 2.5 MW) to LH-modified targets. Vary timing: Before, near, and after the time of sawtooth appearance. Monitor H-mode evolution, and non-thermal
signatures, sawteeth and other MHD, and to the extent possible current profiles. When do sawteeth reappear? Do non-thermals persist? Are pedestals and confinement different than in Step 1?
6+ discharges.

4. To try to separate LH pumpout from current profile effects, take best discharge from step 3, and reduce LH N// to lower value below accessibility limit in H-mode, starting just before the ICRH. Does the pedestal and confinement evolution change? Non-thermals?
2 discharges.

By mid-run, we will raise Ip to 600 kA, and repeat the sequence (hopefully requiring fewer discharges once we have learned the best recipes). Good starting shot is1110106025. Again, start by setting up LHCD-modified target, then add ICRH to make H-mode, and compare to ohmic target.

May repeat one or both currents with higher Bt (around 6 T) to move ICRF heating off axis and see what effect that has on H-mode current profiles. And/or "optimize" any promising scenarios by increasing ICRF power to raise beta and temperature.

Physics Operators Plans
Entered: Feb 3 2011 09:39:23:900AM
Author: Ron Parker
PO Plan for 1110203

MP 642: Assessing feasibility of producing 'hybrid' scenario on C-Mod with LHCD
Session Leader: Amanda Hubbard
Physics Operator: Ron Parker
Run begins at 09:00 and ends at 17:00

----------------------------
Engineering Setup for 1110203
----------------------------

Power systems as on 1080414020. Verify that the OH crowbars are at 0.040 sec and the EF1 crowbars are at .090 sec

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi D2 DISABLED

Enable gate-valves and shutters: ECE, VUV, HiREX Sr, Xeus
Leave z-bolo shutter as is (should be open)

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes, in helium
ICRF(yes/no): yes
LH(yes/no): yes
Cryopump (yes/no): yes
DNB (yes/no): yes

Vessel temperature: 35/35/35

------------------------------
ECDC parameters:
------------------------------


3 hrs in He
sweep: 44/45/103cm
scan: 20/120 s


Session Leader Summaries
Entered: Feb 4 2011 02:24:01:057PM
Author: Amanda Hubbard
Run Summary for Thurs, Feb 3rd 2011

MP 642: Assessing feasibility of producing 'hybrid' scenario on C-Mod with LHCD
Session Leader: Amanda Hubbard
Physics Operator: Ron Parker

This was the first run of what will clearly need to be a more than two run day MP. It was slow going, but we essentially followed the 450 kA part of the run plan, and made good progress though did not get a definite result.

As noted in the Physop summary, establishing a startup slow current rise proved challenging, since it had not been used since roughly the last hybrid run by Sips on 1100414. By noon we had only about 4 discharges into flat top, and they had equilibrium issues. These improved when we decided to stay in LSN for the flat top. However, the perseverence proved worthwhile I believe; we did get nice smooth, well controlled Ip and ne rises, and by later in the run most plasmas were successful.

Shots 12 and, even better, 13 were good ICRF only reference discharges, which had nice steady H-modes with low density - down to nebar 1.5 e20 m-3. 13 had 2.5 MW ICRF, 48 kJ. While we didn't take many shots to optimize, this essentially completed Step 1. ICRF heated well without limiter heating.

Shots 15, 17, 19 and 20 were devoted to Step 2: LHCD only to modify current in startup. This was quite readily acomplished; adding LH 0.25-0.75 s quickly suppressed sawteeth, which returned only in flat top. We tweaked gaps, density in the Ip rise and LH power. Shot 19 was perhaps the best case; 20 had increased radiation and perhaps a locked mode (never had sawteeth). A notable point today is that sawteeth typically appeared at only 300 kA (~ 220 ms).

Combining the LHCD and ICRF to make an LH-modified H-mode, and prospective hybrid scenario, began on shot 21. However, at about this point in the run we began to be plagued with data acquisition issues on several key diagnostics; DNB, HXR camera, D-alpha among others. This caused numerous delays, and we likely have some missing data.

Shot 21 had a prompt H-mode with ICRF, but rather high impurities. Shot 23 had a much delayed H-mode, likely after the LH effects have diminished. Shot 25, with 3 MW ICRF, had a transiently high performance H-mode (60 kJ, H98~1).

In other discharges (eg shot 26) we did not get an H-mode in the ICRF period. Not clear whether this is due to slightly lower density, LHCD effects or something else. In these cases, with nebar ~ 10^20, we did get high k limiter readings and impurity injections. These shots should be useful for tracking non-thermals vs density and ICRF power, in the range of the density limit. All day, the non-linear decrease of non-thermals with density was very apparent. Sawteeth always returned fairly soon after ICRF was turned on, though not immediately; we await analysis of MSE and polatimeter data to see j(r) changes with and without LHCD and ICRF.

In summary, we have good progress MP (and C-Mod milestone) but not yet a clear result. These conditions will be good starting points for another run day which I strongly hope will be scheduled this campaign, and expect to proceed much more quickly now discharges have been developed.

We did, however, serendipitously get enough data to complete an unscheduled MP by David Pace! Shot 1, which had accidental LHCD near t-0, and shot 22, which had LHCD on after a plasma shutdown due to (non-LH induced) runaways, apparently gave much interesting MHD activity (see his logbook entries for details). Shot 22 was also notable in obtaining Vloop < 0.1 V for over 100 me, albeit at low and decreasing Ip.



Physics Operator Summaries
Entered: Feb 3 2011 06:20:31:407PM
Author: Ron Parker
This was a diffiiicult run, primarly because the run plan called for a slow startup, reaching 450 kA after aboout 400 ms. This required adapting a shot from 2008, namely 1080412030. This first of all required updating the predictors on several of the magnetic-coil-derived control signals. Fortunately, Steve Wolfe came to the rescue with a detailed set of instructions for adapting the 2008 shot to the shot needed for this run. Thise instructions are repeated here along with comments regarding their implementation.


1) Request (from engineering) power system setup as on 1080414020. NB: Should have been shot 30). Verify that the OH crowbars are at 0.040 sec and the EF1 crowbars are at .090sec
2) LOAD FROM shot 1110106020, which has more or less your main program
waveforms. This will also preserve the present set of procedures, including
the runaway shutdown and the software for the gas valves.
3) Import Segment 1 (not load from, use IMPORT SEGMENT) from 1080414020. It
will complain about needing to update predictors. Recalculate predictors for
RCUR (change OFFSET from 1000 to 3500 after hitting CALL)
ZCUR (both wires)
zxl
bz_0
BR_0
Do a BUILD_ALL to verify all the changes got made. Watch for a pop-up that
tell you which wires, if any, are still invalid, note the numbers, acknowledge
the popup, and do any wires that were got missed.

Here a problem developed when the build all failed to report that 3 of the predictors had not been updated.This was apparently a problem with the PO's computer and Josh and Steve managed to find a solution.

4) On the V01-16 screen in segment 1 change gas waveforms for startup:
A) change pg4 pulse from 25msec to 50 or 55msec.
B) change pg3 waveform to start at -.019sec at 100V, drop to 40V at +.010,
then flat at 40V to .1sec

This step was done, but in developing the shot it was found that a somewhat different tuning of the PG 3 waveform was required for a smooth startup. See shot 26.

5) In segment 2, change the Ip waveform to start flattop at 0.35sec, and
change the Proportional Gain to go to 8 at .1sec

The value of Ip at the beginning of segment 2 which allowed a smooth connection
to the value of Ip at the endof segment 1 was found empirically.

6) In segment 2, bring up the V#01-16 screen and make the following changes to
reduce or remove feedforward voltages:
A) Change the OH1_VOLT trace to be 0V from 0.05 to 0.1sec, then up to 50V
at .15 sec and flat at 50V to 1.7sec, then down to 0V
B) Set the OH2_U_VOLT trace to be flat at 0V from .1sec to 1.7sec, then
down to 0V
C) Paste the OH2_U_Volt trace into the OH2_L_VOLT trace
D) Set the EF1_U_VOLT trace to be flat at 0V from .1sec to 1.7 sec, then
down to 0V
E) Paste the EF1_U_VOLT trace into the EF1_L_VOLT trace
F) Set the EF2_U_VOLT trace to be flat at 0V from .1sec to 1.7sec, then
down to 0V.
G) Paste the EF2_U_VOLT trace into the EF2_L_VOLT trace
7) Adjust the divert time to be earlier in the rampup. In Segment 2, move the
CLEARIN point at 0.2sec and 0.0 to 0.12sec.

All of these steps were straightforward to implement. (Recall that for pasting, hit the paste button, then use the left mouse button to copy and the middle button to paste.)

I would load this and try to get the startup and rampup working correctly
before making changes to the timing of the swing to UPPER NULL. When you do
get around to that, remember that in addition to changing the time of the ZCUR
sweeps in seg 2, you will need to bring up the CLEARIN screen and change the
time for the second predictor (on row 3).

After implementing these instructions, many shots were required to develop a smooth startup. Two tweaks seemed to be the most beneficial: the programming of the PG 3 gas in segment 1 during commutation and increasing the EF 3 voltage as described in the shot 10 entry.

At any rate, by shot 23 a decent slow startup meeting the run requirements was obtained. Since a goal of the runplan was to create an ICRF H-mode after stabilizing sawteeth with LHCD, relatively high RF power was required (~ 3 MW). At the low current (450 kA) and low densities (nl_04 ~ 4e19) considerable heating of the K limiter occurred, presumably contributing to the relatively high disruptivity in this run.

In summary, roughly half the run was devoted to discharge development, with many fizzles and disruptions. From about shot 17 on, the startup became more reliable and several shots in line with the run plan were obtained. For future reference, shot 26 is perhaps the best example of a shot with slow startup.

Unfortunately, one fairly long delay (~ 1 hour) was encountered due to a problem
with the HXR digitizer and the run was effectively terminated 30 minutes early due to a concern about a vibration issue in the alternator.

Session Leader Comments
Feb 3 2011 09:47:22:893AM1110203001Amanda Hubbard
First plasma ran - not a given after many programming changes. But short and very-non thermal. Density very low, perhaps due to the Helium ECDC. LH fired at t=0 which likely explains the non-thermals!

Current rise was indeed slow as desired, got to 320 kA by 270 ms.

Feb 3 2011 10:15:42:683AM1110203002Amanda HubbardMade it to 1.1 s this time. Slow current rise as desired, reaches 450 kA by 460 ms. ICRF on 0.5-0.8, and LHCD on 0.9-1.1 s; both mainly for conditioning purposes. Both tripping, we got a short H-mode at 0.65 s. D-alpha seems rather high at times in ramp.

Small sawteeth coming in already at 0.137 s, earlier than I'd have expected (only 210 kA)

Next shot request ICRF turnon later, try for a decent H-mode. Also noticed what looks like pickup from ICRF on Bt signal (maybe other magnetics??). Engineers checking for open doors, didn't find any.

Feb 3 2011 10:21:03:827AM1110203003Amanda HubbardFizzle - looks like it almost went.

Feb 3 2011 10:39:22:033AM1110203004Amanda HubbardBetter. Fairly smooth current rise, 450 kA by 0.4 s. Disrupts about 1.3 s,

ICRF on 0.6-0.8; E is tripping and we did not get an H-mode. Given we should be USN by this time, will likely need more power; requesting 3 MW as in our lovely target shot 1110106030.

LH stays on at 350 kW, 0.9-1.3 s, no evident effect.
Feb 3 2011 11:16:29:273AM1110203006Amanda HubbardCurrent rise looks reasonable - Ip and ne rise quite smoothly, though there's a MARFE ~ 0.2 s. Sawteeth start 0.17 s, 300 kA.

Something really bad happened in the part of the shot with ICRF; huge radiation and D-alpha, taking a bite out of Ip and ending in disruption. Went inner wall limited by 0.7, not sure if that was a cause or effect.

Punt on the USN swing for now, and reduce ICRF power to 2 MW. We need to get to a steady reference H-mode!
Feb 3 2011 11:13:24:163AM1110203007Amanda HubbardFizzle
Feb 3 2011 11:23:43:863AM1110203008Amanda HubbardFizzle
Feb 7 2011 09:19:48:620AM1110203009Amanda HubbardFizzle
Feb 3 2011 12:06:10:800PM1110203010Amanda Hubbard
Plasma until 1 sec, disruption. Probably caused by LH-induced radiation?

Nice current rise this time. Got up to 2 MW ICRF, but it is tripping. I think we had a short H-mode, but without Dalpha it is hard to be sure. nebar 1.3 L-mode, 1.7 to 1.6 e20 H-mode, about what we want. Still dropping.

Next shot (when we get one) will turn off LHCD, extend ICRF to 0.9.
Feb 3 2011 12:07:43:997PM1110203011Amanda Hubbardpost-disruption fizzle, as per expectations.
Feb 3 2011 12:29:23:887PM1110203012Amanda HubbardFirst really useful reference shot. ICRF stays on at 2 MW, definite steady H-mode, and density is dropping steadily through it. nebar 1.15 at ICRF o1.8 to 1.55 in the H-mode. Still got a disruption in rampdown, let's hope the startup can cope with it.

Next shot: Move ICRF earlier (0.5-0.9 s) to give more time for density to stabilize. Raise power a little.

ALso, realized target density was higher than I wanted (nel 7.5e19 m-2). Reduce to 6e19, see if I still get steady H-mode. Reducing outer gap. This may be too many changes at once, but time is passing...
Feb 3 2011 12:41:00:673PM1110203013Amanda HubbardTwo in a row! Earlier ICRF and lower target density gave a nice steady H-mode, nebar 1.6-1.5e20 m-3.

While I could take more shots to reduce still further, given the time I will consider this our "Step 1" reference.

Next move to Step 2: Turn off ICRF (for now) and turn on LHCD in the current rise - 0.25 to 0.75 s. This will likely be more challenging for the coupling.
Feb 3 2011 12:49:15:947PM1110203014Amanda HubbardPS dud. Try again. And after a little calculation of accessibility, reduce LHCD N// to about 2.3; should be accessible even in the H-mode with ne this low. And this shot shouldn't have any H-mode.
Feb 3 2011 01:09:27:820PM1110203015Amanda HubbardFirst shot with LHCD in Ip rise (0.25 s, 450 kW, N// 2.3). It did suppress the sawteeth quite promptly, but then Te0 dives. A period 0.35-0.45 s with strong non-thermals, then they disappear and plasma MARFEs. Leading to Ip dip, and disruption at 0.55 s.

Greg requests changes to gap in rise.
Feb 3 2011 01:14:08:543PM1110203016Amanda HubbardFizzle
Feb 3 2011 01:40:21:370PM1110203017Amanda HubbardGood shot. LHCD on clean from 0.25-0.75 s, 400 kW.

Sawteeth disappear 0.32 - 0.55 s. Significant non-thermal ECE, but transient; usual inverse dependence on nebar I think.

Try again with more LH power. Also tweaked the density in rise to try to increase LHCD.
Feb 3 2011 01:44:38:123PM1110203018Amanda HubbardFizzle.
Feb 3 2011 02:08:28:560PM1110203019Amanda HubbardGood shot. 500 to 450 kW in Ip rise, sawteeth suppressed0.32-0.55 secs, and large drop in Vloop. (1.3-0.55 V). LH definitely doing something to j!

Large LH reflection, which Greg attributes to gaps. Tweak this, and the density at 0.3 s. If this goes well I plan to turn ICRF on the following shot.
Feb 3 2011 02:58:06:523PM1110203020Amanda HubbardLHCD only, in Ip rise. Couples better, but Prad is high and sawteeth never appear; we suspect a locked mode. Too low in density? Go back to shot 19 density, and add ICRF next pulse.
Feb 3 2011 02:46:11:057PM1110203021Amanda HubbardPretty good shot. Did suppress sawteeth from about 0.3 s. But, this time Te0 also drops steeply, and there are some LH trips (600kW, some lighting up).

When ICRF is added at 0.5, non-thermals drop. Sawteeth return at 0.52 s, L-H transition I think at 0.53 s. We've unfortunately been lacking several diagnostics due to CAMAC problems.

I note several injections in H-mode. Asked LH to dial back to 500 kW.
WMHD was 39 kW, not I think better than in the reference shot 13. Lower, actually. nebar about 1.5 e 20.
Feb 3 2011 03:14:21:147PM1110203022Amanda HubbardStrong runaways, before LHCD. Railed all the ECE. Early shutdown.
Note LHCD keeps Vloop negative as Ip drops.
Take a break and fix DNB CAMAC.

Now HXR is having data troubles "Overheating". These February heat waves are tough to handle... stay tuned, there will eventually be a shot.
Feb 3 2011 04:00:54:270PM1110203023Amanda HubbardGood plasma (until 1 sec), clean LH at 0.4ish MW and ICRF at at 2.5 MW, as requested. For some reason did not get an H-mode until LH off at 0.8, despite comparable density etc to shot 21. Will at least be a useful ne/RF scan in L-mode.

Retry with more ICRF.
Feb 3 2011 04:02:55:387PM1110203024Amanda Hubbard
H-mode not until 0.58 s, despite clean 3 MW ICRF. By this time sawteeth have long since returned. Suspect density may be a little too low (4 e19 at ICRF on) so raise it. Limiter is getting warm, may contribute to the disruption?
Feb 3 2011 04:19:57:460PM1110203025Amanda HubbardGot the H-mode back, and it was a decent one (while it lasted). 58 kJ, nebar 1.65e20. But soon thereafter there was an injection, and RF tripped; I think we are heating something though the infrared looks OK.

Back off on ICRF power (to 2.5 MW as on shot 21). Will be a better comparison for shot 21 and hopefully keep things cooler.

Just noticed that on this shot sawteeth returned a little BEFORE the ICRF turnon (0.48 s), perhaps due to higher density/less LHCD. The L-H transition is very gradual/indistinct, we've seen this before with LHCD. (circa 1080414)


Feb 3 2011 04:57:58:103PM1110203026Amanda HubbardLost the H-mode, despite quite similar density to prior shots, and clean ICRF at 2.5 MW. LH and ICRF were clean, will be good for HXR comparisons - nebar 1.1 to 0.9 x 10^20. And an injection 0.66 seconds, likely related to k-limiter getting too hot at the lower ne.



Feb 3 2011 04:38:04:990PM1110203027Amanda HubbardNo power - alternator issue. Assuming we get to take the next shot, have asked Yijun to shorten ICRF pulse until we are confident we are getting an H-mode; in L-mode k limiter hit red. It is clearly a density issue, not just Ip; the H-mode shots were fine.


Feb 7 2011 09:21:15:673AM1110203028Amanda HubbardAlternator issue shuts us down again. The plasma gods are not smiling on us. End of run - to be continued another day we hope.

Physics Operator Comments
Feb 3 2011 09:38:07:237AM1110203001Ron ParkerSorry for the delay, lots of reprogramming required for the first shot, trouble with updating predictors.


Feb 3 2011 09:50:49:557AM1110203001Ron ParkerShot disrupted during current rise.

Possible problems: Too much gas, reduce from 50 to 40 ms

Too negative IC_EF4, reduce from -1325 to -1300

Feb 3 2011 10:09:03:753AM1110203002Ron ParkerShot 2 started up better, but disrupted at ~ 1.1 s

Also, segment 1 current was greater than segment 2 program at 0.1 s. We'll fix this by increasing the segment 2 demand at 0.1 s to match the current produced by segment 1 at that time.

Meanwhile, there was pickup from ICRF to magnetics, requiring a cell access to check out.
Feb 3 2011 10:26:50:123AM1110203003Ron ParkerShot 3 disrupted very early, a quasi-fizzle.

Changes: Increase IC_EF4U from -1300 to -1290

Reduce flattop value of PG3 in Segment 1 from 40 V to 30 V.
Feb 3 2011 10:47:12:523AM1110203004Ron ParkerAgain disrupted at ~ 1.1 s, very elongated, almost limited on upper shelf!

Changes: Reduce ZXU by 1 cm and raise ZXL up by 1 cm
Feb 3 2011 10:48:44:490AM1110203005Ron ParkerFizzle, likely due to previous disruption.

Previous changes didn't get loaded, but fizzzle prevented it from getting that far.
Feb 3 2011 11:22:20:730AM1110203006Ron ParkerShot 6 disrupted at t ~ 0.6

Changes: Try to stay in lower null by using 1100106030 without swing to upper null.
Feb 3 2011 11:30:49:773AM1110203007Ron ParkerShot 7 fizzled.

Try setting RCUR Offset to 1000 in Segment 1
Feb 3 2011 11:29:42:440AM1110203008Ron ParkerShot 8 fizzled.

Reset RCUR Offset to 3500 in Segment 1
Feb 3 2011 11:42:28:817AM1110203009Ron ParkerShot 9 fizzled, but RCUR offset change wasn't loaded.

Try again with RCUR Offset at 3500.
Feb 3 2011 12:06:25:157PM1110203010Ron ParkerShot 10 started up (barely) but disrupted at ~ 1 s during LH.

Next: Increase EF3 voltage knots in segment 1 to 2800 at 5 ms, 2800 at 12 ms and 2550 at 20 ms.
Feb 3 2011 12:08:15:983PM1110203011Ron ParkerShot 11 fizzled, try again.
Feb 3 2011 12:29:54:777PM1110203012Ron ParkerShot 12 ran until rampdown.

Changes: Reduce density target to 6.0e19 from 7.5; reduce outer gap by ~ 1 cm after ~ 0.9s, reduce PG3 gas in segment 1 from 100 volts to 50 on first knot.
Feb 3 2011 12:38:54:673PM1110203013Ron ParkerShot 13 ran, reached half way into rampdown.

Startup still a bit ratty, reduce PG 3 still further for next shot.
Feb 3 2011 12:52:02:420PM1110203014Ron ParkerA dud! EF1 commutation failure.
Feb 3 2011 01:10:08:750PM1110203015Ron ParkerShot 15 disrupted at 0.57 s, but was in toouble before that. Maybe LH problems.

Increase outer gap early, also modify RCUR programming near commutation.
Feb 3 2011 01:18:37:073PM1110203016Ron ParkerFizzle. May be due to disruption on shot 15.
Feb 3 2011 01:33:05:327PM1110203017Ron ParkerShot 17 ran full length, as did the LH.

Feb 3 2011 01:47:47:193PM1110203018Ron ParkerAnother fizzle. Add 5 ms more PG 4, from 50 to 55 ms.
Feb 3 2011 02:07:45:807PM1110203019Ron ParkerShot 19 ran full length. OK for LH, clear voltage drop.
Feb 3 2011 02:15:18:390PM1110203020Ron ParkerShot 20 ran full length, but was ugly (locked mode?) during the LH phase.

Try again, raise n back to programmed value for shot 19.
Feb 3 2011 02:28:26:860PM1110203021Ron ParkerShot 21 ran full length, LH had several trips, ICRH "kills" fast electrons.
Feb 3 2011 02:50:15:693PM1110203022Ron ParkerRunaway shutdown!

Next: Increase PG3 puff at commutation.
Feb 3 2011 03:22:43:670PM1110203022Ron ParkerDelay is due to data acquisition problems, particularly with hard X-ray camera.
Feb 3 2011 03:54:45:067PM1110203023Ron ParkerShot 23 started up well, disrupted just after 1 s
Feb 3 2011 03:59:56:453PM1110203024Ron ParkerShot 24 again started up well, but disrupted around 0.7 s

We'll increse density a bit to encourage H-mode.
Feb 3 2011 04:03:30:120PM1110203025Ron ParkerDisruption earlier, at 0.6 s
Feb 3 2011 04:30:58:910PM1110203026Ron ParkerShot 25 ran full length, but no H-mode.
Feb 3 2011 04:35:26:280PM1110203027Ron ParkerShot 27 was a no power shot -- we lost the alternator due to a vibration issue..
Feb 3 2011 04:53:37:617PM1110203028Ron ParkerAgain, alternator lost due to a vibration problem. End of run.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:37:57:877AMPlasmaOk
209:52:00:613AMPlasmaOk
310:15:12:513AMPlasmaOk
410:29:06:543AMPlasmaOk
510:41:42:773AMPlasmaOk
610:54:03:230AMPlasmaOk
711:08:23:547AMPlasmaOk
811:21:04:430AMPlasmaOk
911:34:32:337AMPlasmaOk
1011:47:18:870AMPlasmaOk
1112:00:17:777PMPlasmaOk
1212:14:08:883PMPlasmaOk
1312:28:34:733PMPlasmaOk
1412:42:13:677PMPlasmaBadEF1L commutated early
1512:55:35:207PMPlasmaOkPF Breaker opened after disruption
1601:08:09:953PMPlasmaOk
1701:23:29:290PMPlasmaOk
1801:39:46:910PMPlasmaOk
1901:53:23:863PMPlasmaOk
2002:06:57:003PMPlasmaOk
2102:20:29:670PMPlasmaOk
2202:44:34:943PMPlasmaOk
2303:33:01:310PMPlasmaOk
2403:48:05:060PMPlasmaOk
2504:00:45:797PMPlasmaOk
2604:17:35:917PMPlasmaOk
2704:31:43:683PMPlasmaBadNo Power Alternator vibration alarm
2804:48:07:837PMPlasmaBadAlternator bearing vibration no power shot

System Availability
Feb 3 2011 09:37:37:607AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennasears,snipes
BESyesBES system is onlineOct 21 2010 11:33AM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi (D+F) working. All midplane and off-midplane diode arrays working except WB1AX. Midplane foils calibrated and PRAD_MAIN is being filled. Divertor/Ledge foils not yet ready.Jul 15 2010 08:27AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationyes Nov 16 2010 02:36PM (dekow)Jim IrbyBoronizationdekow,irby
CNPAyesMultiple channel CNPA availableOct 21 2010 07:11PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertornoShut down. Helium dewar removed. LN2 manual valve and solenoid valves are closed and tagged.Apr 06 2010 10:51AM (labombard)Brian LaBombardUpper Divertor Cryopumpirby,labombard
CXRSyesWide-view CXRS system is onlineOct 21 2010 11:33AM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsayessystem is aligned; new calibrations (relative brightness and position) not yet implementedJun 29 2010 10:27AM (marmar)Earl MarmarVisible Bremsstrahlungmarmar
Disruption Mitigationyesoperational, but turned offNov 03 2009 04:59PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DNBnoin test mode onlyNov 03 2009 05:01PM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,gung
ECDCyesOperationalJun 26 2010 09:28PM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesAll channels working and calibrated.Oct 27 2010 03:41PM (phillips)Perry PhillipsHeterodyne ECE-32 channelsphillips
G-Side RatiomaticyesGauges are operational.Jun 28 2010 08:02PM (labombard)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoPlugs for Power Supply and Controls have been unplugged and red tagged making system safe for In-Vessel Access.Apr 05 2010 11:18AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperational.Jul 28 2009 04:23PM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPC2yesMost channels operational. Oct 22 2010 11:46AM (hubbard)Amanda HubbardECE Polychromaterhubbard,schmidt
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyesoperating normallyJun 29 2010 10:26AM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Jun 26 2010 11:19PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SryesSystem installed and aligned. Inverted Profiles for Ti are available upon request. Vtor profiles still under revision.Dec 17 2010 09:25AM (ypodpaly)John RiceHigh Resolution X-Rayince,rice,ypodpaly
HXRyes32 Channels operationalOct 23 2010 01:41PM (parker)Ron ParkerHard X-Ray Arrayfaust,parker,schmidt
ICRF D-Antennayessystem checked out ok on 11006728. Jun 28 2010 04:57PM (ylin)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayessystem checked out ok on 1100628Jun 28 2010 04:57PM (ylin)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayessystem checked out ok. conditioned to vacuum. Jun 28 2010 04:58PM (ylin)Steve WukitchJ-port antennawukitch,ylin
Laser Blow-Offyesoperational and testedJul 20 2010 04:42PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridyesLH working. New directional couplers installed at input to each klystron.Oct 21 2010 11:42AM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
Lower Hybrid Reflectometeryes50GHz: up-, 60 GHz up- and down-Oct 21 2010 11:31AM (sgbaek)Arturo DominguezLower Hybrid Reflectometerdominguez,marmar,parker,sgbaek
Lower Hybrid SOL reflectometeryesprofiles and fluctuations both working. If requested, please request LH launcher to be moved in.Jan 18 2011 03:07PM (cornwall)Cornwall LauLower Hybrid SOL reflectometercornwall,wukitch,ylin
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphanoWB4LY and LLY working but not during ICRF. WB1LY not attached due to pickup problems. LYMID attached but have profile problems.Aug 24 2010 09:17AM (mlreinke)Matt ReinkeLyman alpha cameraslabombard,mlreinke
McPhersonyesSpectra being collected and tree filled. Wavelength scan is broken so fixed on the Mo XXXI and XXXII lines.Jul 15 2010 08:28AM (mlreinke)Jim TerryVUV Spectrometermlreinke,terry
MichelsonyesOperational. Oct 22 2010 11:46AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyesGauges are operationalJun 28 2010 08:02PM (labombard)Brian LaBombardBaratron pressure gaugeslabombard
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEnoAs of 6/10/09, MSE is calibrated & ready to go. Awaiting DNB.Jun 10 2009 10:34AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesAll systems are on and functionalJun 29 2010 12:56PM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesPMT Neuts_hards, ssd_x01, ssd_x02, ssd_x03Jun 26 2010 09:21PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAnoCapillaries tested in-vessel.Jun 28 2010 08:08PM (labombard)Brian LaBombardNINJA gas pufflabombard,terry
PCIyesOperational. AM (2 * 39.51) MHz.Dec 13 2010 05:29PM (ntsujii)Miklos PorkolabPhase Contrast Imagingennever,ntsujii,porkolab
Penning GaugesnoHigh voltage power supplies are turned off, waiting for work at A-port horizontal to be finished.Jun 28 2010 08:07PM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
PolarimeternoSafe for Machine EntrySep 14 2007 12:17PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Jun 26 2010 11:19PM (dekow)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Jun 26 2010 11:19PM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Jun 26 2010 11:19PM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Jun 26 2010 11:20PM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational.Jun 28 2010 08:03PM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational.Jun 28 2010 08:03PM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesF and J outer divertor probes are operational.Jun 28 2010 08:04PM (labombard)Brian LaBombardOuter Lower Divertor Probe Arraylabombard
Probe Array - UDIVyesOperational, except probe#13Jun 28 2010 08:04PM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesAs of 1101123, the 60, 88u, 88l, 140 and variable set at 115GHz are operational. The 50, 75 and 112 are nonoperational. On 1101123, the noise band at ~200kHz is again seen on the 88u and 88l channels.Nov 23 2010 09:30AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational. New Langmuir-Mach probe head installed.Jun 28 2010 08:05PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.Jun 28 2010 08:05PM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesBoth A and K units are operational. Coil polarity needs to be checked.Jun 28 2010 08:06PM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
SparkeryesHV supply on, cable run to sparker at k-horJun 23 2010 02:41PM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationyesSSS installed and leak tested.Oct 21 2010 11:31AM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesNo new CO2 detector, so still missing edge channelsJun 23 2010 02:40PM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CoreyesOperating with 2 lasersOct 22 2010 01:06PM (jwhughes)Jerry HughesCore Thomson scatteringjwhughes,yma
TS - EdgeyesOperationalJul 14 2010 11:54AM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesRaw spectra stored but not line brightness time histories are going into the tree yet.Jan 20 2011 10:45AM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermlreinke
XTOMOyesCore system working. Edge system waiting for H-modes.Jul 01 2010 11:55AM (mlreinke)Bob GranetzX-Ray Tomographygranetz,mlreinke