| System | Available | Comment | Availability Changed | Owner | Description | Who Can Change |
| Active MHD | no | secured - tagged out | Jun 02 2008 11:03AM (sears) | Joe Snipes | Active MHD Antenna | golfit |
| BES | no | BES system is offline, no safety risk for in-vessel access | Apr 14 2011 01:20PM (bespam) | Bill Rowan | Beam Emission Spectroscopy | bespam,liao,rowan |
| Bolometers | no | WB3,WB4 and ledge box removed from vessel, WB1, WB2 and KLIM still installed | May 04 2011 08:39AM (mlreinke) | Matt Reinke | Bolometers | hutch,mlreinke |
| Boronization | no | Bottle Removed. Magnetron Unplugged | Apr 11 2011 09:51AM (dekow) | Jim Irby | Boronization | dekow,irby |
| CNPA | yes | Multiple channel CNPA available, no safety risk for in-vessel access | Apr 14 2011 12:01PM (parker) | Ron Parker | Compact Neutral Analyzer | parker |
| Cryopump - Upper Divertor | no | Shut down. Helium dewar removed. LN2 manual valve closed/ red-tagged and solenoid valves are closed | Apr 15 2011 10:55AM (dekow) | Brian LaBombard | Upper Divertor Cryopump | dekow,irby,labombard |
| CXRS | no | core-CXRS system is offline, no safety risk for in-vessel access | Apr 14 2011 01:20PM (bespam) | Bill Rowan | Charge Exchange Spectroscopy | bespam,blip,liao,rachmcd,rowan |
| CXRS edge | yes | Michael CHurchill has primary responsibility at the moment | Apr 19 2011 11:44AM (blip) | Bruce Lipshultz | Measurement of CXR light in the pedestal region at both the high- and low-field sides | blip,rmchurch |
| D Alpha | yes | \ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not available | Jul 01 2009 09:45AM (terry) | Jim Terry | Balmer Alpha Monitor | irby,terry,wolfe |
| Dalsa | no | system is secured for the shutdown, and poses no safety risk for in-vessel access; camera removed from k-port | Jun 02 2011 10:21AM (marmar) | Earl Marmar | Visible Bremsstrahlung | marmar |
| Disruption Mitigation | no | gas jet valve disabled on 2011/04/13 | Apr 13 2011 02:04PM (granetz) | Robert Granetz | Gas Jet | granetz,whyte |
| Divertor IR | no | | Mar 06 2007 10:50AM | Glen Wurden | Divertor IR Digital Video | gwurden,terry |
| Divertor IR Spectroscopy | no | | Mar 06 2007 10:51AM | Glen Wurden | Divertor IR Spectroscopy | gwurden,terry |
| DNB | no | gate valve disabled on 2011/04/13 | Apr 13 2011 02:03PM (granetz) | Robert Granetz | Diagnostic Neutral Beam | dterry,granetz,gung |
| ECDC | no | Magnetron Unplugged | Apr 11 2011 09:51AM (dekow) | Jim Irby | 2.45 GHz, 3 kW, discharge cleaning system | dekow,irby,pfeiffer |
| FRC-ECE | no | Power off to RF and IF sections- Power on to DA | Apr 11 2011 02:54PM (phillips) | Perry Phillips | Heterodyne ECE-32 channels | bespam,liao,phillips,rowan,whitea |
| G-Side Ratiomatic | no | Power supply OFF Gauge removed | Apr 14 2011 09:52AM (labombard) | Brian LaBombard | G-side ratiomatic ionization gauge | labombard,toland |
| Glow Discharge | no | Power supply unplugged and redtagged, HV cables removed | Apr 14 2011 08:03AM (dekow) | Jim Irby | 1 kV, 5 A, glow discharge system | dekow,dterry,irby |
| GPC | no | Gate valve disabled. Dewar cold to test improved preamps. | Apr 19 2011 10:49AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt |
| GPC2 | no | Dewar warmed up. Gate valve disabled. | Apr 19 2011 10:48AM (hubbard) | Amanda Hubbard | ECE Polychromater | hubbard,schmidt |
| GPI | yes | The Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. | Jul 01 2009 09:45AM (terry) | Jim Terry | Gas Puff Imaging | terry,zweben |
| H/D | yes | no safety risk for in-vessel access; | Apr 14 2011 11:47AM (marmar) | Earl Marmar | H/D Ratio | marmar |
| HEAT | no | Breakers off and red tagged | Apr 14 2011 11:27AM (dekow) | Gary Dekow | - Machine Heaters - | burke,dekow |
| Hirex Jr | yes | Hirex-Jr has been installed | Jun 28 2010 03:36PM (rice) | John Rice | High Resolution X-Ray | ince,rice |
| Hirex Sr | no | System removed from cell and placed into storage pending reinstallation of B-port. | Apr 20 2011 03:12PM (ypodpaly) | John Rice | High Resolution X-Ray | ince,rice,ypodpaly |
| HXR | yes | 32 Channels operational,, no safety risk for in-vessel access | Apr 14 2011 12:05PM (parker) | Ron Parker | Hard X-Ray Array | faust,parker,schmidt |
| ICRF D-Antenna | no | secured | Apr 14 2011 08:55AM (wukitch) | Steve Wukitch | D-port antenna | wukitch,ylin |
| ICRF E-Antenna | no | secured | Apr 14 2011 08:55AM (wukitch) | Steve Wukitch | E-port antenna | wukitch,ylin |
| ICRF J-Antenna | no | secured | Apr 14 2011 08:56AM (wukitch) | Steve Wukitch | J-port antenna | wukitch,ylin |
| Impurity Spectroscopy | yes | Being upgraded with better optics and new spectrographs. Dan Miller has primary responsibility. | Apr 19 2011 11:46AM (blip) | Bruce Lipshultz | Measurement of recycling light and impurity source rates at multiple surfaces around the tokamak | blip,miller |
| Laser Blow-Off | no | Beamline disconnected | Apr 14 2011 11:53AM (g) | Martin Greenwald | Impurity Injection System | g,nthoward |
| Lower Hybrid | no | LH HV Breaker Opened and Tagged, Positioner Motor Cables Locked off. Safe for In-vessel work. | Apr 15 2011 10:03AM (dterry) | Ron Parker | Lower Hybrid | dterry,parker,wallaceg |
| Lower Hybrid Reflectometer | no | off | Apr 15 2011 08:24AM (dominguez) | Arturo Dominguez | Lower Hybrid Reflectometer | dominguez,marmar,parker,sgbaek |
| Lower Hybrid SOL reflectometer | no | please notify if moving LH or reflectometer components | Apr 14 2011 08:57AM (wukitch) | Cornwall Lau | Lower Hybrid SOL reflectometer | cornwall,wukitch,ylin |
| LPI | no | Beam line removed | May 30 2008 02:09PM (bose) | Earl Marmar | Lithium Pellet Injector | bose,marmar |
| Ly-alpha | no | WB4 and LEDGE removed, WB1 and KLIM still in-vessel | May 04 2011 08:40AM (mlreinke) | Matt Reinke | Lyman alpha cameras | labombard,mlreinke |
| McPherson | no | still under vacuum, MCP high voltage is off | Apr 13 2011 11:53AM (mlreinke) | Jim Terry | VUV Spectrometer | mlreinke,terry |
| Michelson | no | Front end pumps off, gate valve disabled, dewar warming up. | Apr 19 2011 10:49AM (hubbard) | Amanda Hubbard | ECE Te Profiles | hubbard,schmidt |
| MKS | no | Secured for work. Power supplies are turned off. | Apr 14 2011 11:37AM (labombard) | Brian LaBombard | Baratron pressure gauges | labombard,toland |
| MLP | no | System is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it. | Jul 14 2009 09:20PM (labombard) | Brian LaBombard | Mirror Langmuir Probe Electronics System | labombard |
| MSE | no | no safety risk for in-vessel access as of 4/14/2011 | Apr 14 2011 11:48AM (sscott) | Steve Scott | Motional Stark Effect | jinseok,sscott |
| Neutrons | no | High voltage is turned off on all detectors. | Apr 11 2011 10:27AM (fiore) | Catherine Fiore | Neutron Detectors | fiore |
| Neuts and Hards | yes | No safety risk for in-vessel access | Apr 14 2011 12:06PM (irby) | Jim Irby | X-Ray/Neutron Detectors at K-Hor | irby |
| NINJA | no | Secured for vessel entry. Backfilled plenum to helium, disconnected feed line to capillary valves at C-bottom. | Apr 14 2011 11:44AM (labombard) | Brian LaBombard | NINJA gas puff | labombard,terry,toland |
| PCI | no | Secured for in-vessel work | Apr 14 2011 06:21PM (ntsujii) | Miklos Porkolab | Phase Contrast Imaging | emd,ennever,ntsujii,porkolab |
| Penning Gauges | no | Secured for vessel entry/work. High voltage power supplies are turned off, all 8 cables HV cables are unplugged at J-port rack | Apr 14 2011 09:56AM (labombard) | Brian LaBombard | Penning Ionization Gauges | labombard |
| Plasma TV | yes | WIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational. | Jul 01 2009 09:46AM (terry) | Jim Terry | Video of plasma via several cameras | dekow,irby,terry,wolfe |
| Polarimeter | no | Safe for Machine Entry | Sep 14 2007 12:17PM (irby) | Jim Irby | C-Mod Polarimeter | irby |
| Power - Alternator Air Switch | no | Red tagged off | Apr 12 2011 07:23AM (dekow) | Gary Dekow | feeds all the other supplies | cochran,dekow,dterry,irby |
| Power - PEI | no | Breaker opened and red tagged | Apr 11 2011 11:59AM (dekow) | Gary Dekow | PEI System | cochran,dekow,dterry,irby |
| Power - TMX | no | Breakers opened and red tagged | Apr 11 2011 12:00PM (dekow) | Gary Dekow | Ef2s,. EFCs and A-Coils | byford,cochran,dekow,dterry,irby |
| Power Systems | no | All systems disabled for in-vessel entry | Apr 14 2011 11:29AM (dekow) | Jim Irby | C-Mod Magnet Supplies | byford,cochran,dekow,dterry,irby |
| Probe Array - ISD | no | Secured for vessel entry. Power supplies turned off, all probe cables unplugged at F-port rack. | Apr 14 2011 09:56AM (labombard) | Brian Labombard | Inner Lower Divertor Probe Array | labombard |
| Probe Array - LH | no | Secured for vessel entry. Power supplies turned off, all probe cables unplugged at A-port rack. | Apr 14 2011 09:57AM (labombard) | Brian LaBombard | Lower Hybrid Probe Array | labombard |
| Probe Array - OSD | no | Secured for vessel entry. Power supplies turned off, all probe cables unplugged at A-port and F-port racks. | Apr 14 2011 09:58AM (labombard) | Brian LaBombard | Outer Lower Divertor Probe Array (F and J) | labombard |
| Probe Array - UDIV | no | Secured for vessel entry. Power supplies turned off, all probe cables unplugged at F-port rack. | Apr 14 2011 09:58AM (labombard) | Brian LaBombard | Upper Divertor Probe Array | labombard |
| Reflectometer | no | off | Apr 15 2011 08:24AM (dominguez) | Earl Marmar | Reflectometer | dominguez,marmar |
| Scanning Probe - ASP | no | Secured for vessel entry. Power supplies turned off, air turned off and hose disconnected, all probe cables unplugged at A-port rack. | Apr 14 2011 09:59AM (labombard) | Brian LaBombard | A-Port Scanning Probe | labombard |
| Scanning Probe - FSP | no | Secured for vessel entry. Power supplies turned off, air turned off and hose disconnected, all probe cables unplugged at F-port rack. | Apr 14 2011 09:59AM (labombard) | Brian LaBombard | F-Port Scanning Probe | labombard |
| Scanning Probe - WASP | no | Secured for vessel entry. Power supplies turned off, Kepco cable unplugged, all probe cables unplugged at F-port rack. | Apr 14 2011 11:39AM (labombard) | Brian LaBombard | Inner Wall Scanning Probe | labombard,nsmick |
| Sparker | no | HV supply off and unplugged from 120VAC, HV cable disconnected at sparker | Apr 11 2011 11:25AM (parkin) | Jim Irby | Field Emission Preionization for C-Mod | dekow,irby,parkin |
| Surface Science Station | no | SSS is up to air, no safety issues | Apr 14 2011 12:06PM (ochoukov) | Bruce Lipschultz | Radially scanning probe located on K-port | blip,ochoukov |
| TCI | no | Lasers have been powered down and system is safe for machine entry | Apr 13 2011 11:34AM (murray) | Jim Irby | Two-Color Interferometer | irby,murray |
| TS - Core | no | All lasers are shut down and cannot be fired into cell. | Apr 11 2011 01:20PM (jwhughes) | Jerry Hughes | Core Thomson scattering | jrwalk,jwhughes,yma |
| TS - Edge | no | All lasers are shut down and cannot be fired into cell. | Apr 11 2011 01:20PM (jwhughes) | Jerry Hughes | Millimeter resolution edge Thomson scattering | jrwalk,jwhughes,yma |
| Vispec | no | 350 and 670 nm, 4 spatial channels | Nov 28 2007 09:58AM (agraf) | Alex Graf | Visible Spectrometer | agraf |
| XEUS | no | XEUS has been removed from the cell | Apr 13 2011 11:52AM (mlreinke) | Matt Reinke | X-ray Extended Ultraviolet Spectrometer | mlreinke |
| XTOMO | no | ARRAY1 and ARRAY3 Be filters removed for spatial calibrations | May 04 2011 08:40AM (mlreinke) | Bob Granetz | X-Ray Tomography | granetz,mlreinke |